mailto:info@promicro.co.za
http://www.promicro.co.za
Serial Device Servers
�
Serial Device Server Overview
Connect Your Devices to the eWorld
6-2
Serial Device Server Applications
6-3
Serial Device Server Selection Guide
6-4
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
Serial Device Servers
EKI-1528
EKI-1526
8-port RS-232/422/485 Serial Device Server
16-port RS-232/422/485 Serial Device Server
6-6
EKI-1521
EKI-1522
EKI-1524
1-port RS-232/422/485 Serial Device Server
2-port RS-232/422/485 Serial Device Server
4-port RS-232/422/485 Serial Device Server
6-8
ADAM-4571/L
ADAM-4570/L
1-port RS-232/422/485 Serial Device Server
2-port RS-232/422/485 Serial Device Server
6-9
EKI-1351
EKI-1352
1-port RS-232/422/485 to 802.11b/g WLAN Serial Device Server
2-port RS-232/422/485 to 802.11b/g WLAN Serial Device Server
6-10
Modbus Gateways
Modbus Gateway Solutions
6-11
EKI-1221
EKI-1222
EKI-1224
1-port Modbus Gateway
2-port Modbus Gateway
4-port Modbus Gateway
6-12
ADAM-4572
1-port Modbus Gateway
6-13
Programmable Device Servers
EKI-1121L (New)
EKI-1122L (New)
1-port Programmable Device Server
2-port Programmable Device Server
6-14
Serial to USB Converters
ADAM-4561
ADAM-4562
1-port Isolated USB to RS-232/422/485 Converter
1-port Isolated USB to RS-232 Converter
6-15
USB-4604B
USB-4604BM
4-port RS-232 Serial to USB Converter with ESD Surge Protection
4-port Serial to USB Converter with ESD Surge Protection
6-16
http://www.promicro.co.za
mailto:info@promicro.co.za
52 Shepherd Avenue, Bryanston, South Africa
P O Box 593, Cramerview, 2060, South Africa
Connect Your Devices to
the eWorld
Introduction
As the world becomes more and more wired, it is critical to manage and connect devices. Advantech offers comprehensive and cost-effective eConnectivity solutions for easy installation
and operation in critical industrial environments. These solutions meet the requirements from worldwide enterprises that need supervisory control, operator interfaces, and logging
of events and alarms via serial communication over Ethernet networks.
Serial Device Servers
Advantech’s serial device servers offer the easiest way to enable RS-232/422/485 serial
devices to be connected to host over Ethernet network quickly and cost-effectively.
COM port redirector makes integration of existing serial application with network-level
application an easy task. No extra programming effort is required at the host, so software
development costs can be saved. Advantech’s serial device servers are especially suitable
for remotely controlling and monitoring your serial devices via Ethernet.
Wireless Serial Device Servers
Advantech wireless serial device servers EKI-1351 and EKI-1352 make it possible to
quickly connect RS-232/422/485 serial devices with PC hosts via 802.11b/g wireless
LAN networks. Functionally transparent and efficient, EKI-1351 and EKI-1352 save
costs when existing hardware and software must continue to be used and also bring the
advantages of remote management and data accessibility to RS-232/422/485 devices
that cannot connect to the network.
Modbus Gateways
Serial Device Servers
ADAM-4570 and EKI-1500 series are cost-effective serial device servers which enable
users to easily connect equipment with an RS-232/422/485 serial port to the Ethernet.
Through TCP/UDP, IP, Socket or Winsock, ADAM-4571, ADAM-4570, and EKI-1500 series
can be used for different operating systems ranging from Microsoft Windows to Linux.
Moreover, these serial device servers can use serial tunneling communications without
any intermediate host PCs and software programming to save costs and effort, allowing
two native serial devices to communicate over a network. After COM port redirector
installation, the ADAM-4570 series and EKI-1500 series serial ports will be configured as
a virtual COM port on the host. Standard serial operating calls are transparently redirected
to these serial device servers. Advantech serial device servers provide high transmission
speeds up to 921.6 kbps to offer the best performance in the industrial and ensure that the
critical application will not be harmed by data throughput. COM port redirection (Virtual
COM), TCP/UDP server/client mode, various operating mode are supported and especially
suitable for different serial applications.
Advantech Modbus gateways ADAM-4572, EKI-1221, and EKI-1222 present an interface
between Modbus serial devices and computer hosts or HMIs running Modbus/TCP on
Ethernet networks. Fully compliant with Modbus/TCP, Advantech Modbus gateways offer
a convenient solution to connect existing devices or controllers running Modbus serial
protocol (Modbus/ASCII or Modbus/RTU) to an Ethernet network.
Serial to USB Converters
The industrial-grade USB to serial converters (ADAM-4561/4562, USB-4604B/4604BM)
are especially suitable for wide variety of industries such as banking, retail, factory
automation, and industrial automation. USB to serial converters provide software selectable
RS-232/422/485 ports that are compatible with all standard RS-232 or RS-422/485 serial
devices and suitable for printers, POS systems, and industrial control devices. Use them
to expand your serial ports fast, easily, and cost-effectively.
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
Serial Device Server System Architecture
6-2
Serial Device Servers
http://www.promicro.co.za
mailto:info@promicro.co.za
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
Serial Device Server
Applications
Multi-Access
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Operator Panels
Traditional --- Single Access
Most serial devices are connected directly to the PC serial port via cable. The OS, such as Windows XP, provides the COM ports that the application can access, and control the serial
device through the serial cable. This means that the serial device can be connected to one host and only one application on this host can handle input, output and control operation. Fanless Panel PCs
Advanced --- Multi-Access
Advantech ADAM-4570 series, EKI-1500 series, and EKI-1300 series allow a maximum of 5 hosts connected to one serial port simultaneously and handle the commands from each Panel Computers
host and reply to all hosts or the host that query depending on the easily configuration. Advantech serial device servers have two kinds of operating modes for multi-access. First
is broadcast mode; serial device servers handle a command from one application and reply the data from the serial port to all applications connected to this serial port. The other is
polling mode; serial device servers handle the command from one application and reply to this application only. Query from other applications must be queued and wait for current Display Solutions
process completion.
Dual Ethernet Redundancy
Ethernet Switches
Advantech EKI-1500 series provide dual Ethernet connections for building reliable and redundant networks. Through the serial device servers, users can establish two physical
networks in the same domain, one for the primary connection, and the other is a backup host that can connect to the serial device servers directly when the primary connection fails.
Device Servers
Furthermore, the two Ethernet ports can be set to two different networking domains to support different network applications.
Serial Comm. Cards
Video Surveillance
Pre-Configured Systems
IPC Chassis
SBCs and Backplanes
Industrial Motherboards
Wireless Serial Tunneling
Embedded IPCs
Two native serial devices can communicate over a wireless Ethernet network without any intermediate host PC and software programming. Both Ad-hoc and infrastructure mode for
wireless operation are selectable so that EKI-1300 series wireless serial device servers can connect to an AP (Access Point) or two EKI-1300 series wireless serial device servers can
Mobile Computers
directly communicate without AP.
IPC Peripherals
DAQ
Signal Conditioning
USB DAQ
Online Download www.advantech.com/products
6-3
P O Box 593, Cramerview, 2060, South Africa
mailto:info@promicro.co.za
52 Shepherd Avenue, Bryanston, South Africa
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
http://www.promicro.co.za
Serial Device Server
Selection Guide
6-4
Serial Device Servers
Model Name
EKI-1351
EKI-1352
EKI-1521
EKI-1522
No. of Ethernet Port
WLAN
WLAN
2
2
EKI-1524
2
No. of Serial Port
1
2
1
2
4
Ethernet Interface
802.11 b/g
802.11 b/g
10/100 Mbps
10/100 Mbps
10/100 Mbps
Serial Type
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232/422/485
Ethernet
SMA
SMA
RJ45
RJ45
RJ45
Serial
DB9
DB9
DB9
DB9
DB9
Baud Rate
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
Operating Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Driver
Windows 2000/XP/Vista
Windows 2000/XP/Vista
Windows 2000/XP/Vista
Windows 2000/XP/Vista
Windows 2000/XP/Vista
Page
6-10
6-10
6-8
6-8
6-8
Connector
Model Name
EKI-1528
EKI-1526
ADAM-4571
ADAM-4571L
ADAM-4570
No. of Ethernet Port
2
2
1
1
1
1
No. of Serial Port
8
16
1
1
2
2
ADAM-4570L
Ethernet Interface
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Serial Type
RS-232/422/485
RS-232/422/485
RS-232/422/485
RS-232
RS-232/422/485
RS-232
Ethernet
RJ45
RJ45
RJ45
RJ45
RJ45
RJ45
Serial
RJ45
RJ45
DB9
DB9
RJ48
RJ48
Connector
Baud Rate
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
Operating Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Virtual COM, Data
Mode, Control Mode
Driver
Windows 2000/XP/
Vista
Windows 2000/XP/
Vista
Windows 2000/XP/
Vista
Windows 2000/XP/
Vista
Windows 2000/XP/
Vista
Windows 2000/XP/
Vista
Page
6-6
6-6
6-9
6-9
6-9
6-9
Serial Device Servers
mailto:info@promicro.co.za
P O Box 593, Cramerview, 2060, South Africa
52 Shepherd Avenue, Bryanston, South Africa
Tel: 011-706-7913
ProMicro cc
Fax: 011-706-2766
http://www.promicro.co.za
Selection Guide
Modbus Gateways
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Operator Panels
Fanless Panel PCs
Panel Computers
Model Name
EKI-1221
EKI-1222
EKI-1224
ADAM-4572
No. of Ethernet Port
2
2
2
1
No. of Serial Port
1
2
4
1
Ethernet Interface
10/100 Mbps
10/100 Mbps
10/100 Mbps
10/100 Mbps
Serial Type
RS-232/422/485
Connector
RS-232/422/485
RS-232/422/485
RS-232/422/485
Ethernet
RJ45
RJ45
RJ45
RJ45
Serial
DB9
DB9
DB9
Screw Terminal
Baud Rate
50 ~ 921.6 kbps
50 ~ 921.6 kbps
50 ~ 921.6 Kbps
50 ~ 921.6 kbps
Operating Mode
Modbus RTU Master/Slave,
Modbus ASCII Master/Slave
Modbus RTU Master/Slave,
Modbus ASCII Master/Slave
Modbus RTU Master/Slave,
Modbus ASCII Master/Slave
Modbus RTU Master/Slave,
Modbus ASCII Master/Slave
Driver
Windows 2000/XP/Vista
Windows 2000/XP/Vista
Windows 2000/XP/Vista
Windows 2000/XP/Vista
Page
6-12
6-12
6-12
6-13
Display Solutions
Ethernet Switches
Device Servers
Serial Comm. Cards
Video Surveillance
Pre-Configured Systems
Serial to USB Converters
IPC Chassis
SBCs and Backplanes
Industrial Motherboards
Model Name
ADAM-4561
ADAM-4562
USB-4604B
USB-4604BM
Interface
USB 1.1
USB 1.1
USB 1.1/2.0
USB 1.1/2.0
Serial Port
1
1
4
4
Baud Rate
50 ~ 115.2 kbps
75 ~ 115.2 kbps
50 ~ 921.6 kbps
50 ~ 921.6 kbps
Serial Type
RS-232/422/485
RS-232
RS-232
RS-232/422/485
USB
Type B
Type B
Type B
Type B
Serial
Screw Terminal
DB9
DB9
DB9
Isolation
3,000 VDC (RS-232/422/485)
2,500 VDC
-
-
Surge
3,000 VDC (RS-485)
-
2,500 VDC
2,500 VDC
Windows 2000/XP/2003,
CE5.0
6-16
Connector
Protection
Driver
Windows 2000/XP
Windows 2000/XP
Windows 2000/XP/2003,
CE5.0
Page
6-15
6-15
6-16
Embedded IPCs
Mobile Computers
IPC Peripherals
DAQ
Signal Conditioning
USB DAQ
Online Download www.advantech.com/products
6-5
8-port RS-232/422/485 Serial Device Server
16-port RS-232/422/485 Serial Device Server
mailto:info@promicro.co.za
http://www.promicro.co.za
EKI-1528
EKI-1526
Features
� 8 or 16-port RS-232/422/485 serial communication
� Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
� Supports baud rate up to 921.6 kbps
� Provides COM port redirection (Virtual COM), TCP and UDP operation modes
� Provides rich configuration methods: Windows utility, Telnet console, Web
Browser, and serial console
� Built-in 15 KV ESD protection for all serial signals
� SNMP MIB-II for network management
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
� Built-in buzzer for easy location
� Standard 1U rackmount size
� Rear wiring
� Automatic RS-485 data flow control
EKI-1528
����
COMPLIANT
����������
Introduction
EKI-1528 and EKI-1526 are industrial-grade network-based serial device servers for connecting up to 8 or 16 serial RS-232/422/485 devices, such as CNCs, PLCs, scales and
scanners, directly to a TCP/IP network. The EKI-1528 and EKI-1526 feature two independent Ethernet ports and MAC addresses to provide a redundant network mechanism to guarantee
Ethernet network reliability. The EKI-1528 and EKI-1526 provide a simple and cost-effective way to bring the advantages of remote management and data accessibility to thousand of
devices that can't connect to an Ethernet network. The EKI-1528 and EKI-1526 offer rich ways to configure through Windows utility, Web Browser, serial console or Telnet console,
these methods make it easy manage many EKI-1528 and EKI-1526 or serial devices on your network.
Specifications
Ethernet Communications
Mechanics
�
�
�
�
�
�
�
�
�
IEEE 802.3, IEEE 802.3u
10/100 Mbps, auto MDI/MDIX
2
8-pin RJ45
Built-in 1.5 KV magnetic isolation
Compatibility
Speed
No. of Ports
Port Connector
Protection
Serial Communications
� Port Type
� No. of Ports
�
�
�
�
�
�
�
Port Connector
Data Bits
Stop Bits
Parity
Flow Control
Baud Rate
Serial Signals
� Protection
RS-232/422/485, software selectable
EKI-1528: 8
EKI-1526: 16
8-pin RJ45
5, 6, 7, 8
1, 1.5, 2
None, Odd, Even, Space, Mark
XON/XOFF, RTS/CTS, DTR/DSR
50 bps ~ 921.6 kbps
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
15 KV ESD for all signals
Software
� Driver Support
� Utility Software
� Operation Modes
� Configuration
� Protocols
� Management
6-6
EKI-1526
Windows 2000/XP/Vista
Advantech Serial Device Server Configuration Utility
COM port redirection mode (Virtual COM)
TCP/UDP server (polling) mode
TCP/UDP client (event handling) mode
Pair connection (peer to peer) mode
Windows utility, Telnet console, Web Browser, serial
console
ICMP, IP, TCP, UDP, BOOTP, DHCP, Auto IP, Telnet,
SNMP, HTTP, DNS, SMTP, ARP, HTTPS, SSL, SSH,
NTP
SNMP MIB-II
Serial Device Servers
Dimensions (H x W x D) 44 x 440 x 220 mm
Enclosure
SECC chassis
Mounting
Rack
Weight
EKI-1528: 2.53 kg
EKI-1526: 2.58 kg
General
� LED Indicators
� Alert Tools
� Reboot Trigger
System: Power, System Status
LAN: Speed, Link/Active
Serial: Tx, Rx
Built-in buzzer and RTC (real time clock)
Built-in WDT and push button for hardware reboot
Power Requirements
� Power Input
� Power Consumption
100 ~ 240 VAC, 47 ~ 63 Hz
EKI-1528: 8 W
EKI-1526: 10 W
Environment
� Operating Temperature 0 ~ 60° C (32 ~ 140° F)
� Storage Temperature -20 ~ 80° C (-4 ~ 176° F)
� Operating Humidity
5 ~ 95% RH
Regulatory Approvals
� EMC
� MTBF
CE, FCC Part 15 Subpart B (Class A)
EKI-1528: 198,571 hrs
EKI-1526: 175,708 hrs
mailto:info@promicro.co.za
http://www.promicro.co.za
EKI-1528
EKI-1526
Dimensions
Unit: mm
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Operator Panels
Fanless Panel PCs
Panel Computers
480
440
5.65
6-M3x0.5Px2L
Ethernet Switches
9
20 20
220
225.80
2.80
15 14.5
Device Servers
Serial Comm. Cards
Video Surveillance
Pre-Configured Systems
Dimensions (W x D x H): 440 x 220 x 44 mm
IPC Chassis
Physical Views
Ordering Information
EKI-1528: Front View
� EKI-1528
� EKI-1526
8-port RS-232/422/485 Serial Device Server
16-port RS-232/422/485 Serial Device Server
*All items include 1pc OPT1J
�
�
�
�
�
�
OPT1I
OPT1J
1702002600
1702002605
1702031801
1702031836
SBCs and Backplanes
Industrial Motherboards
Accessories
EKI-1528: Rear View
ProMicro cc
Ø6
6
6
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
32
44
Display Solutions
1 m RJ45 to DB9 Male Cable
30 cm RJ45 to DB9 Male Cable
Power Cable US Plug 1.8m
Power Cable EU Plug 1.8m
Power Cable UK Plug 1.8m
Power Cable China/Australia Plug 1.8m
Embedded IPCs
Mobile Computers
IPC Peripherals
EKI-1526: Front View
DAQ
Signal Conditioning
EKI-1526: Rear View
USB DAQ
Online Download www.advantech.com/products
6-7
1-port RS-232/422/485 Serial Device Server
2-port RS-232/422/485 Serial Device Server
4-port RS-232/422/485 Serial Device Server
mailto:info@promicro.co.za
http://www.promicro.co.za
EKI-1521
EKI-1522
EKI-1524
Features
� Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
� Provides COM port redirection (Virtual COM), TCP and UDP operation modes
� Supports baud rate up to 921.6 kbps
� Allows a max. of 5 hosts to access one serial port
� Allows a max. of 16 hosts to be accessed as TCP client mode
� Built-in 15 KV ESD protection for all serial signals
� Provides rich configuration methods including Windows utility, Telnet
console, and Web Browser
P O Box 593, Cramerview, 2060, South Africa
52 Shepherd Avenue, Bryanston, South Africa
� Supports Windows 2000/XP/Vista drivers
� Automatic RS-485 data flow control
� Class I, Division 2 certification
EKI-1521
EKI-1522
EKI-1524
����
COMPLIANT
����������
Introduction
EKI-1521, EKI-1522 and EKI-1524 feature two independent Ethernet ports and MAC addresses to provide a redundant network mechanism to guarantee Ethernet network reliability.
EKI-1521, EKI-1522 and EKI-1524 are serial device servers that connect RS-232/422/485 serial devices, such as PLC, meters, sensors, and barcode reader to an IP-based Ethernet
LAN. They allow nearly any device with serial ports to connect and share an Ethernet network. EKI-1521, EKI-1522 and EKI-1524 provide various operations: COM port redirection
(Virtual COMport), TCP Server, TCP Client and UDP mode. With COM port redirection mode, standard serial operation calls are transparently redirected to the EKI-1521, EKI-1522
and EKI-1524, guaranteeing compatibility with legacy serial devices and enabling backward compatibility with existing software. With TCP server, TCP client, and UDP modes, EKI1521, EKI-1522 and EKI-1524 ensure the compatibility of network software that uses a standard network API. Moreover, you can make serial devices communicate with other devices
peer-to-peer, without any intermediate host PCs and software programming.
Specifications
Mechanics
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
Ethernet Communications
�
�
�
�
�
Serial Communications
� Port Type
� No. of Ports
�
�
�
�
�
�
�
Port Connector
Data Bits
Stop Bits
Parity
Flow Control
Baud Rate
Serial Signals
� Protection
� Driver Support
� Utility Software
� Operation Modes
� Management
General
� LED Indicators
RS-232/422/485, software selectable
EKI-1521: 1
EKI-1522: 2
EKI-1524: 4
DB9 male
5, 6, 7, 8
1, 1.5, 2
None, Odd, Even, Space, Mark
XON/XOFF, RTS/CTS, DTR/DSR
50 bps ~ 921.6 kbps
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
Built-in 15 KV ESD for all signals
Software
� Configuration
� Protocol
6-8
IEEE 802.3, IEEE 802.3u
10/100 Mbps
2
8-pin RJ45
Built-in 1.5 KV magnetic isolation
Compatibility
Speed
No. of Ports
Port Connector
Protection
� Dimensions (W x H x D EKI-1521/1522: 37 x 140 x 95 mm
EKI-1524: 55 x 140 x 95 mm
� Enclosure
Metal with solid mounting hardware
� Mounting
DIN-rail, Panel
� Weight
EKI-1521: 592g
EKI-1522: 600g
EKI-1524: 668g
Windows 2000/XP/Vista
Advantech Serial Device Server Configuration Utility
COM port redirection mode (Virtual COM)
TCP/UDP server (polling) mode
TCP/UDP client (event handling) mode
Pair connection (peer to peer) mode
Windows utility, Telnet console, Web Browser
ICMP, IP, TCP, UDP, BOOTP, DHCP, Auto IP, Telnet,
SNMP, HTTP, DNS, SMTP, ARP, NTP
SNMP MIB-II
Serial Device Servers
� Reboot Trigger
System: Power, System Status
LAN: Speed, Link/Active
Serial: Tx, Rx
Built-in WDT (watchdog timer)
Power Requirements
� Power Input
� Power Connector
� Power Consumption
12 ~ 48 VDC, redundant dual inputs
Terminal block
EKI-1521: 2 W
EKI-1522: 2.5 W
EKI-1524: 4W
Environment
� Operating Temperature -10 ~ 60° C (14 ~ 140° F)
� Storage Temperature -20 ~ 80° C (-4 ~ 176° F)
� Operating Humidity
5 ~ 95% RH
Regulatory Approvals
� EMC
� Safety
� MTBF
� Hazardous Location
CE, FCC Part 15 Subpart B (Class A)
UL (UL60950-1)
EKI-1521: 1,102,913 hrs
EKI-1522: 1,000,154 hrs
EKI-1524: 862,230 hrs
UL/cUL Class I, Division 2
Ordering Information
� EKI-1521
� EKI-1522
� EKI-1524
1-port RS-232/422/485 Serial Device Server
2-port RS-232/422/485 Serial Device Server
4-port RS-232/422/485 Serial Device Server
mailto:info@promicro.co.za
http://www.promicro.co.za
ADAM-4571/L
ADAM-4570/L
1-port RS-232/422/485 Serial
Device Server
2-port RS-232/422/485 Serial
Device Server
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Operator Panels
Fanless Panel PCs
Panel Computers
P O Box 593, Cramerview, 2060, South Africa
52 Shepherd Avenue, Bryanston, South Africa
Display Solutions
Ethernet Switches
Fax: 011-706-2766
Tel: 011-706-7913
����
����������
����������
COMPLIANT
COMPLIANT
Specifications
Mechanics
�
�
�
�
�
�
�
�
�
Compatibility
Speed
No. of Ports
Port Connector
Protection
IEEE 802.3, IEEE 802.3u
10/100 Mbps
1
8-pin RJ-45
Built-in 1.5 KV magnetic isolation
� Port Connector
�
�
�
�
�
�
Data Bits
Stop Bits
Parity
Flow Control
Baud Rate
Serial Signals
� Protection
ADAM-4571/4570: RS-232/422/485, software selectable
ADAM-4571L/4570L: RS-232
ADAM-4571/4571L: 1
ADAM-4570/4570L: 2
ADAM-4571/4571L: DB9 male
ADAM-4570/4570L: 10-pin RJ48
5, 6, 7, 8
1, 1.5, 2
None, Odd, Even, Space, Mark
XON/XOFF, RST/CTS, DTR/DSR
50 bps ~ 921.6 kbps
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
15 KV ESD protection for all signals
� Configuration
� Protocol
70 x 130 x 30 mm
ABS+PC with solid mounting hardware
DIN-rail, stack, wall
ADAM-4571/4571L: 135g
ADAM-4570/4570L: 160g
� LED Indicators
� Reboot Trigger
System: Power, System Status
LAN: Speed, Link/Active
Serial: Tx, Rx
Built-in WDT (watchdog timer)
Power Requirements
� Power Input
� Power Connector
� Power Consumption
10 ~ 30 VDC
Terminal block
ADAM-4571/4571L: 1.5 W
ADAM-4570/4570L: 2 W
Windows 2000/XP/Vista
Advantech Serial Device Server Configuration Utility
COM port redirection (Virtual COM)
TCP/UDP server (polling) mode
TCP/UDP client (event handling) mode
Pair Connection (peer to peer) mode
Windows utility, Telnet console, Web Browser
ICMP, IP, TCP, UDP, BOOTP, DHCP, Auto IP, Telnet,
SNMP, HTTP, DNS, SMTP, ARP
� Operating Temperature 0 ~ 60° C (32 ~ 140° F)
� Storage Temperature -20 ~ 80° C (-4 ~ 176° F)
� Operating Humidity
5 to 95% RH
� EMC
CE, FCC Part 15 Subpart B (Class A)
Ordering Information
� ADAM-4571
1-port RS-232/422/485 Serial Device Server
� ADAM-4571L
1-port RS-232 Serial Device Server
� ADAM-4570
2-port RS-232/422/485 Serial Device Server
� ADAM-4570L
2-port RS-232 Serial Device Server
*ADAM-4570/4570L includes 2pcs OPT1A
Pre-Configured Systems
IPC Chassis
SBCs and Backplanes
Industrial Motherboards
Mobile Computers
IPC Peripherals
DAQ
Signal Conditioning
USB DAQ
Accessories
� OPT1A
� OPT1D
Video Surveillance
Embedded IPCs
Environment
Regulatory Approvals
Software
� Driver Support
� Utility Software
� Operation Modes
Dimension (H x W x D)
Enclosure
Mountion
Weight
General
Serial Communications
� Port Type
Device Servers
Serial Comm. Cards
Ethernet Communications
� No. of Ports
ProMicro cc
����
1 m RJ48 to DB9 Male Cable
30 cm RJ48 to DB9 Male Cable
Online Download www.advantech.com/products
6-9
mailto:info@promicro.co.za
http://www.promicro.co.za
EKI-1351
EKI-1352
1-port RS-232/422/485 to 802.11b/g WLAN
Serial Device Server
2-port RS-232/422/485 to 802.11b/g WLAN
Serial Device Server
Features
� Link any serial device to an IEEE 802.11 b/g network
� Supports wireless LAN Ad-Hoc and Infrastructure modes
� Provides COM port redirection, TCP, UDP, and pair connection modes
� Supports baud rate up to 921.6 kbps
� Provides Web-based configuration and Windows utility
� Allows a max. of 5 hosts to access one serial port
� Supports Windows 2000/XP/Vista drivers
� Allows a max. of 4 hosts to be accessed as TCP client mode
P O Box 593, Cramerview, 2060, South Africa
52 Shepherd Avenue, Bryanston, South Africa
� Built-in 15 KV ESD protection for all serial signals
� Supports DHCP protocol
� Supports secure access with WEP, WPA, WPA2
EKI-1351
EKI-1352
����
COMPLIANT
����������
Introduction
EKI-1351 and EKI-1352 are wireless serial device servers that bring RS-232/422/485 to wireless Ethernet. They allow nearly any device with serial ports to connect and share an
Wireless Ethernet network. EKI-1351 and EKI-1352 provide a quick, simple and cost-effective way to bring the advantages of remote management and data accessibility to thousands
of devices that cannot connect to a network.
With EKI-1351 and EKI-1352, your existing serial devices can be used with the most popular operating systems on the market. There is no need to write special drivers for specific
operating systems. Moreover, you can make serial devices communicate with other devices peer-to-peer, without any intermediate host PCs and software programming. That saves a
lot of cost and effort. In addition, you can actively request data or issue commands from the RS-232/422/485 side or Wireless Ethernet side. This data can be sent bilaterally. Thus,
the EKI-1351 and EKI-1352 are especially suitable for remote monitoring environments such as security systems, factory automaton, SCADA, transportation and more.
Specifications
Mechanics
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
Ethernet Communications
6-10
�
�
�
�
�
�
IEEE 802.11b, IEEE 802.11g
11/54 Mbps
Infrastructure, Ad-Hoc
Reverse SMA
Open space 100m
WEP, WPA, WPA2
Compatibility
Speed
Network Mode
Antenna Connector
Free Space Range
Wireless Security
Serial Communications
� Port Type
� No. of Ports
�
�
�
�
�
�
Port Connector
Data Bits
Stop Bits
Parity
Baud Rate
Serial Signals
� Protection
RS-232/422/485, software selectable
EKI-1351: 1
EKI-1352: 2
DB9 male
5, 6, 7, 8
1, 1.5, 2
None, Odd, Even, Space, Mark
50 bps ~ 921.6 kbps
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
15 KV ESD for all signals
Dimensions (W x H x D) 37 x 140 x 95 mm
Enclosure
Metal with solid mounting hardware
Mounting
DIN-rail, Panel
Weight
EKI-1351: 595g
EKI-1352: 603g
General
� LED Indicators
� Reboot Trigger
System: Power, System Status
WLAN: Quality, Fail, Link/Active
Serial: Tx, Rx
Built-in WDT (watchdog timer)
Power Requirements
� Power Input
� Power Connector
� Power Consumption
12 ~ 48 VDC, redundant dual inputs
Terminal block
EKI-1351: 3.5 W
EKI-1352: 4 W
Environment
� Operating Temperature 0 ~ 50° C (32 ~ 122° F)
� Storage Temperature -20 ~ 80° C (-4 ~ 176° F)
� Operating Humidity
5 ~ 95% RH
Regulatory Approvals
Software
� Driver Support
� Utility Software
� Operation Modes
�
�
�
�
Windows 2000/XP/Vista
Advantech Serial Device Server Configuration Utility
COM port redirection mode (Virtual COM)
TCP/UDP server (polling) mode
TCP/UDP client (event handling) mode
Pair connection without AP (peer to peer) mode
Serial Device Servers
� EMC
� Safety
� Hazardous Location
CE, FCC Part 15 Subpart B (Class B)
UL (UL60950-1)
UL/cUL Class I, Division 2
Ordering Information
� EKI-1351
� EKI-1352
1-port 802.11b/g WLAN Serial Device Server
2-port 802.11b/g WLAN Serial Device Server
mailto:info@promicro.co.za
http://www.promicro.co.za
Modbus Gateway Solutions
Introduction
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Operator Panels
Ethernet networks have become increasingly vital for industrial automation applications. Many control devices today do not have an Ethernet port and can only communicate with a
dedicated local PC or control panel. Advantech’s revolutionary network-enabling technology is now allowing control devices with serial ports to connect to the Ethernet and share
networks quickly and cost-effectively. The EKI-1221 and EKI-1222 are network-based, Modbus Gateways for integrating new and existing Modbus/RTU or Modbus/ASCII serial devices
Fanless Panel PCs
to newer Modbus/TCP networked-based devices. Manufacturers, system integrators, and end users can now take advantages of the EKI-1221 and EKI-1222 to create networked
applications for remote managing and accessing data for control devices that was not possible before.
Panel Computers
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
Display Solutions
Ethernet Switches
Device Servers
Serial Comm. Cards
Video Surveillance
Modbus Protocol
Originally developed for PLCs in automation and manufacturing control applications, Modbus has become one of the most popular open standard protocols worldwide. When it Pre-Configured Systems
comes to planning data communications for open, multi-vendor industrial control systems, Modbus is the first choice of end-users and system integrators alike. Although it is not
the most powerful protocol available, its rare simplicity allows not only rapid implementation, but also remains flexible enough to be applied in virtually all industrial situations. The
communication modes of Modbus include ASCII, RTU or TCP/IP. The EKI-1221 and EKI-1222 are used to support applications such as protocol conversion between serial (Modbus/ IPC Chassis
ASCII or Modbus/RTU) and networked (Modbus/TCP) Modbus devices or it can be used to bridge Modbus serial devices over Ethernet TCP/IP network.
The Modbus/RTU and Modbus/ASCII protocols define how a “master” device polls one or more “slave” devices to read and write real-time data over RS-232, RS-422, or RS-485
serial data communication.
SBCs and Backplanes
During Modbus network communications, the protocol determines how each controller will know its device address, recognize a message addressed to it, determine the kind of action to
be taken, and extract any data or other information contained in the message. If a reply is required, the controller will construct the reply message and send it back using Modbus protocol.
The way controllers communicate with each other is by using a master-slave technique, in which only one device (the master) can initiate queries. The other devices (slaves) respond Industrial Motherboards
by supplying the requested data to the master, or by taking the action requested in the query. Typical master device includes host processors and programming panels. Typical slaves
include programmable controllers.
The master can address individual slaves and initiate a broadcast message to all slaves. On the other hand, slaves return a response to queries that are addressed to them individually. Embedded IPCs
Responses are not returned to broadcast queries from the master.
The Modbus protocol has a definite format for the master’s query, which incorporates the device address, a function code defining the requested action, any data to be sent, and an
error-checking field. The slave’s response message, which is also constructed using Modbus protocol, contains fields confirming the action taken, any data to be returned, and an Mobile Computers
error-checking field. If an error occurred in receipt of the message, or if the slave is unable to perform the requested action, the slave will construct an error message and send it as
its response.
IPC Peripherals
DAQ
Signal Conditioning
USB DAQ
Online Download www.advantech.com/products
6-11
1-port Modbus Gateway
2-port Modbus Gateway
4-port Modbus Gateway
mailto:info@promicro.co.za
http://www.promicro.co.za
EKI-1221
EKI-1222
EKI-1224
Features
� Provides 2 x 10/100 Mbps Ethernet ports for LAN redundancy
� Integration of Modbus TCP and Modbus RTU/ASCII networks
� Supports baud rates up to 921.6 kbps
� Supports up to 16 connections and 32 requests simultaneously
� Supports 31 slaves per serial port
� Easy-managing Advantech Serial Device Server Configuration Utility for
Windows 2000/XP/Vista
� Auto searching slave ID over configuration utility
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
� Software selectable RS-232/422/485 communication
� Mounts on DIN-rail, wall or panel
� Built-in 15 KV ESD protection for all serial signals
� Automatic RS-485 data flow control
EKI-1221
EKI-1224
����
COMPLIANT
����������
Introduction
The EKI-1200 series Modbus gateways are bi-directional gateways for integrating new and existing Modbus/RTU and Modbus/ASCII serial devices to newer TCP/IP networked-based
devices. The EKI-1221/1222/1224 feature two independent Ethernet ports and MAC addresses to provide a redundant networking mechanism to guarantee Ethernet networking
reliability. They provide a simple and cost-effective way to bring the advantage of remote management and data accessibility to thousand of devices that can not connect to a network.
The EKI-1221/1222/1224 provide a feature that can allow users to select master or slave operation mode for each serial port. They not only allow an Ethernet master to control serial
slaves, but also allow serial masters to control Ethernet slaves.
Specifications
Ethernet Communications
Mechanics
�
�
�
�
�
� Dimensions (W x H x D) EKI-1221/1222: 37 x 140 x 95 mm
EKI-1224: 55 x 140 x 95 mm
� Enclosure
Metal with solid mounting hardware
� Mounting
DIN-rail, Panel
� Weight
EKI-1221: 592g
EKI-1222: 600g
EKI-1224: 668g
IEEE 802.3, IEEE 802.3u
10/100 Mbps
2
8-pin RJ45
Built-in 1.5 KV magnetic isolation
Compatibility
Speed
No. of Ports
Port Connector
Protection
Serial Communications
� Port Type
� No. of Ports
�
�
�
�
�
�
�
Port Connector
Data Bits
Stop Bits
Parity
Flow Control
Baud Rate
Serial Signals
� Protection
RS-232/422/485, software selectable
EKI-1221: 1
EKI-1222: 2
EKI-1224: 4
DB9 male
7, 8
1, 2
None, Odd, Even, Space, Mark
XON/XOFF, RTS/CTS, DTR/DSR
50 bps ~ 921.6 kbps
RS-232: TxD, RxD, CTS, RTS, DTR, DSR, DCD, RI, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
15 KV ESD for all signals
Software
� OS Support
� Utility Software
� Operation Modes
Windows 2000/XP/Vista
Advantech Serial Device Server Configuration Utility
Modbus RTU Master/Slave mode
Modbus ASCII Master/Slave mode
General
� LED Indicators
� Reboot Trigger
6-12
EKI-1222
System: Power, System Status
LAN: Speed, Link/Active
Serial: Tx, Rx
Built-in WDT (watchdog timer)
Serial Device Servers
Power Requirements
� Power Input
� Power Connector
� Power Consumption
12 ~ 48 VDC, redundant dual inputs
Terminal block
EKI-1221: 2 W
EKI-1222: 2.5 W
EKI-1224: 4 W
Environment
� Operating Temperature -10 ~ 60° C (14 ~ 140° F)
� Storage Temperature -20 ~ 80° C (-4 ~ 176° F)
� Operating Humidity
5 ~ 95% RH
Regulatory Approvals
� EMC
� Safety
� Hazardous Location
CE, FCC Part 15 Subpart B (Class A)
UL (UL60950-1)
UL/cUL Class I, Division 2
Ordering Information
� EKI-1221
� EKI-1222
� EKI-1224
1-port Modbus Gateway
2-port Modbus Gateway
4-port Modbus Gateway
mailto:info@promicro.co.za
http://www.promicro.co.za
ADAM-4572
1-port Modbus Gateway
Features
� Supports 10/100 Mbps communication speeds
� Allows up to 8 clients to access field data simultaneously
� Supports popular HMI software with Modbus/TCP driver or OPC server
� Up to 3 Independent serial ports capacity if configured to RS-485 serial mode
� Provides auto-searching device ID Windows utility
� Surge protection for RS-485 and power line
� Automatic RS-485 data flow control
� Easy mounting on DIN-rail or panel
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
� Supports Modbus/ASCII, RTU Protocol to control devices
ProMicro cc
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Operator Panels
Fanless Panel PCs
Panel Computers
Display Solutions
Ethernet Switches
Device Servers
����
COMPLIANT
����������
Specifications
Serial Comm. Cards
Ethernet Communications
General
� Compatibility
� Speed
� Port Connector
� Certifications
� LED Indicators
IEEE 802.3, IEEE 802.3u
10/100 Mbps
8-pin RJ45
Serial Communications
�
�
�
�
�
�
�
�
Port Type
No. of Ports
Port Connector
Data Bits
Stop Bits
Parity
Baud Rate
Data Signals
� Power Input
� Power Consumption
Video Surveillance
Pre-Configured Systems
Power Requirement
RS-232/422/485
1
Plug-in terminal block
7, 8
1, 2
None, Odd, Even, Mark, Space
50 bps ~ 921.6 kbps
RS-232: TxD, RxD, GND
RS-422: TxD+, TxD-, RxD+, RxD-, GND
RS-485: Data+, Data-, GND
10 ~ 30 VDC
1.5 W
Environment
IPC Chassis
� Operating Temperature 0 ~ 60° C (32 ~ 140° F)
� Storing Temperature
-20 ~ 80° C (-4 ~ 176° F)
� Operating Humidity
5 ~ 95% RH
SBCs and Backplanes
Ordering Information
Industrial Motherboards
� ADAM-4572
Software
� OS Support
� Utility Software
� Operation Mode
CE, FCC Part 15 Subpart B (Class A)
System: Power, System Status
LAN: Speed, Link/Active
Serial: Tx, Rx
1-port Modbus Gateway
Windows 2000/XP/Vista
Advantech Serial Device Server Configuration Utility
Modbus/RTU master/slave mode,
Modbus/ASCII master/slave mode
Mechanics
� Dimensions (H x W x D) 70 x 130 x 30 mm
� Enclosure
ABS+PC with solid mounting hardware
� Mounting
DIN-rail, stack, wall
Embedded IPCs
Mobile Computers
IPC Peripherals
DAQ
Signal Conditioning
USB DAQ
Online Download www.advantech.com/products
6-13
mailto:info@promicro.co.za
http://www.promicro.co.za
EKI-1121L
EKI-1122L
1-port Programmable Device Server
2-port Programmable Device Server
Features
NEW
� ARM7 32-bit 80MHz processor
� 8MB Flash ROM on board
� 16MB SDRAM
� 2 x 10/100 Mbps Ethernet ports for LAN redundancy
� 1 or 2 software selectable RS-232/422/485 serial ports
� 50 bps to 921.6 kbps baud rate
� Built-in real-time clock (RTC)
� Class I, Division 2 certification
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
� Pre-installed Linux Kernel 2.4 platform
EKI-1121L
����
COMPLIANT
����������
Introduction
EKI-1121L and EKI-1122L are RISC-based embedded communication controllers which provide dual auto-sensing 10/100 Mbps Ethernet ports for network redundancy and one or
two software-selectable RS-232/422/485 serial ports. The EKI-1121L and EKI-1122L use the ARM7 RISC CPU which is a powerful computing engine to fulfill data compression or
protocol conversion requirements. The built-in 8 MB flash ROM and 16 MB SDRAM provide user enough storage to run their specific applications.
Specifications
System
�
�
�
�
�
�
CPU
Flash
SDRAM
OS (pre-installed)
Console Port
Other
Mechanics
ARM7 32-bit RISC CPU, 80 MHz
8 MB
16 MB
uClinux
RS-232, 3-wire (Tx, Rx, GND) pin-header
RTC, watchdog timer
� LAN
� Connector
� Protection
2 x auto-sensing 10/100 Mbps ports
RJ-45
1.5 kV magnetic isolation protection
Serial Interface
� Serial Standards
� Connectors
� Protection
Software selectable RS-232/422/485 ports
D-sub 9 male
15 kV ESD protection for all signals
Serial Parameters
�
�
�
�
Data Bits
Stop Bits
Parity
Flow Control
� Baud Rate
5, 6, 7, 8
1, 1.5, 2
None, Even, Odd, Space, Mark
RTS/CTS, XON/XOFF, automatic RS-485 data flow
control
50 bps to 921.6 kbps
Serial Signals
� RS-232
� RS-422
� RS-485
�
�
�
�
Dimensions
Housing
Weight
Mounting
TxD, RxD, DTR, DSR, RTS, CTS, DCD, RI, GND
TxD+, TxD-, RxD+, RxD-, GND
Data+, Data-, GND
LEDs
OS ready, power 1 and power 2 ready
Speed (10/100 Mbps), link/active (on connector)
TxD, RxD
Serial Device Servers
37 x 140 x 95 mm (W x H x D)
Metal
600g
DIN-rail, Panel
Power Requirements
� Input Voltage
� Power Consumption
Ethernet Interface
� System
� LAN
� Serial
6-14
EKI-1122L
12 ~ 48 VDC, redundant dual inputs
2.5 W
Software (uClinux)
� Kernel Version
� Protocol Stack
�
�
�
�
�
File System
System Utility
Daemon
Linux Tool Chain
uClibc
2.4.31
TCP, UDP, IPv4, ICMP, ARP, SNMP V1, HTTP, DHCP,
NTP, NFS, SMTP, Telnet, FTP, PPP, PPPoE
ROMFS/JFFS2
busybox, telnet, ftp, sash, tftp
pppd, snmpd, telnetd, inted, ftpd, boa
Arm-elf-gcc: C/C++ PC Cross Compiler
POSIX Standard Library
Environmental Limits
� Operating Temperature -10 ~ 60° C (14 ~ 140° F)
� Storage Temperature -20 ~ 80° C (-4 ~ 176° F)
� Operating Humidity
5 ~ 95 % RH
Regulatory Approvals
� EMC
� Hazardous Location
CE, FCC Part 15 Subpart B (Class A)
UL/cUL Class I, Division 2
Ordering Information
� EKI-1121L
� EKI-1122L
1-port Programmable Device Server
2-port Programmable Device Server
1-port Isolated USB to RS-232/422/485 Converter
1-port Isolated USB to RS-232 Converter
mailto:info@promicro.co.za
http://www.promicro.co.za
ADAM-4561
ADAM-4562
Features
� RS-232/422/485 port supported (only ADAM-4561)
� Transmission speed up to 115.2 kbps
� Isolation protection 3,000 VDC provided for ADAM-4561 and 2,500 VDC for
ADAM-4562
� Automatic RS-485 data flow control
� No external power supply necessary
� Plug & Play installation
� No additional IRQs or I/O ports required
P O Box 593, Cramerview, 2060, South Africa
Fax: 011-706-2766
Tel: 011-706-7913
52 Shepherd Avenue, Bryanston, South Africa
� Hot swap function supported
Fanless Panel PCs
Panel Computers
Display Solutions
Ethernet Switches
ADAM-4561
ADAM-4562
Device Servers
����
COMPLIANT
����������
Specifications
Ordering Information
General
� ADAM-4561
� ADAM-4562
� Certifications
� Connectors
� Enclosure
� Mounting
� Power Consumption
1-port Isolated USB to RS-232/422/485 Converter
1-port Isolated USB to RS-232 Converter
CE, FCC Part 15 Subpart B (Class A)
USB: USB Type B (Type A to Type B cable provided)
Serial: Plug-in terminal (ADAM-4561) or DB9 male
(ADAM-4562)
ABS+PC
DIN-rail, stack, wall
ADAM-4561: 270 mA @ 5 V (Typical)
300 mA @ 5 V (Max.)
ADAM-4562: 155 mA @ 5 V (Typical)
220 mA @ 5 V (Max.)
Communications
�
�
�
�
Data Bits
Error Detection
Max. Distance
Parity Bits
� RS-232 Signals
� Stop Bits
� Transmission Speed
ProMicro cc
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Operator Panels
� Surge Protection
Driver Support
Operating Temperature
Storage Temperature
Operating Humidity
Pre-Configured Systems
IPC Chassis
Industrial Motherboards
Embedded IPCs
Mobile Computers
IPC Peripherals
ADAM-4561: 3,000 VDC (RS-232/422/485)
ADAM-4562: 2,500 VDC
3,000 VDC (RS-485)
DAQ
Software
�
�
�
�
Video Surveillance
SBCs and Backplanes
5, 6, 7, 8
Parity error, frame error, serial break (ADAM-4562)
15 ft (4.6 m)
ADAM-4561: None, Odd, Even
ADAM-4562: None, Odd, Even, Mark, Space
ADAM-4561: 3-wire (Tx, Rx, GND)
ADAM-4562: 9-wire
1, 1.5, 2
ADAM-4561: 50 bps to 115.2 kbps
ADAM-4562: 75 bps to 115.2 kbps
Protection
� Isolation Protection
Serial Comm. Cards
Windows 2000/XP
0 ~ 70° C (32 ~ 158° F)
-25 ~ 85° C (-13 ~ 185° F)
20 ~ 95% RH
Signal Conditioning
USB DAQ
Online Download www.advantech.com/products
6-15
mailto:info@promicro.co.za
http://www.promicro.co.za
USB-4604B
USB-4604BM
4-port RS-232 Serial to USB Converter
with ESD Surge Protection
4-port Serial to USB Converter with ESD
Surge Protection
Features
� Full compliance with USB V1.1 and V2.0 specifications
� RS-232/422/485 port supported
� Transmission speed up to 921.6 kbps
� Automatic RS-485 data flow control
� Bus-powered; no need for external power supply
� Plug & Play installation
� No additional IRQs or I/O ports required
P O Box 593, Cramerview, 2060, South Africa
52 Shepherd Avenue, Bryanston, South Africa
� Hot swap function supported
����
COMPLIANT
����������
Introduction
USB-4604 series allows PC users to connect a serial device to a system that use a USB interface. To attach the USB-4604B/4604BM to a PC, you don’t need to open the chassis or
power down your PC. Instantly get extra high-speed RS-232/422/485 ports. The power is derived from the USB port, so there are no power adapters to deal with. This makes the
USB-4604B/4604BM especially suitable for modems, printers, POS systems and industrial control devices.
Supporting USB2.0 high speed, USB-4604B/4604BM features several powerful functions such as high-speed 921.6 kbps transmission, support for various operating systems,
independent RS-232/422/485 ports and more. By simply plugging in a USB hub, USB-4604B and USB-4604BM eliminates the configuration issues associated with high-priced,
older card solutions. You only have to install the drivers, no need to set cards slots, IRQ addresses, DMA channels, or device addresses. This reduces programming effort.
Specifications
Mechanism
Fax: 011-706-2766
ProMicro cc
Tel: 011-706-7913
General
6-16
� Certifications
� Connectors
� Enclosure
� USB Cable
CE, FCC (Class A)
1 x USB Type B (Type A to Type B cable provided)
4 x DB9
ABS+PC
Max. 15ft (4.6 m)
Data Bits
Parity
Stop Bits
Transmission Speed
Environment
5, 6, 7, 8
None, Odd, Even, Space, Mark
1, 1.5, 2
Up to 921.6 kbps
Ordering Information
Protection
� EFT Protection
� ESD Protection
Windows 2000/XP/2003, Windows CE 5.0
10 to 48 VDC (external) or 5 VDC (Bus powered)
130 mA @ 5 V (Typical)
200 mA @ 5 V (Max.)
Communications
�
�
�
�
132 x 80 x 32 mm
ABS+PC
DIN-rail, panel
Software
� Driver Support
Insert
� Power Input
� Power Consumption
� Dimensions
� Enclosure
� Mounting
2,500 VDC
IC Embedded 16KV
Serial Device Servers
� Operating Temperature 0 ~ 55° C (32 ~ 131° F)
� Storage Temperature -25 ~ 80° C (-13 ~ 176° F)
� Operating Humidity
20 ~ 95% RH
� USB-4604B
� USB-4604BM
4-port RS-232 to USB Converter w/ESD
4-port RS-232/422/485 to USB Converter w/ESD