QuickSpecs
HP ProLiant DL560
Overview
1. Dual 550W Hot Plug Redundant Power
2. 2U (3.5" Height) rack form factor
3. PCI-X Riser Cage, Three 64-bit PCI-X slots
4. Six memory DIMM slots
5. Tool-less "Snap in" Rail Solution
6. Hood
7. LEDs
8. Slimline Removable media Bay with 24x CD-ROM installed
9. Hood latch (accesses processors and fans)
10. 1.44 MB Diskette Drive
11. Wide Ultra3 SCSI drive cage for two hot plug hard drives or
one DAT hot plug tape drive (plus 1 hard drive)
12. Hot Plug Fans
13. DC Power Converter Module
What's New
Intel® Xeon® Processors MP at 3.0 GHz/4MB, 2.7 GHz/2MB, or 2.2 GHz/2MB (Expandable to 4 processors)
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 1
QuickSpecs
HP ProLiant DL560
Overview
At a Glance
Intel Xeon Processors MP at 3.0 GHz/4MB, 2.7 GHz/2MB, 2.2 GHz/2MB, 2.8 GHz/2MB, 2.5 GHz/1MB, 2.0 GHz/1MB
(Expandable to 4 processors)
The HP ProLiant DL560 delivers extraordinary performance and maximum power efficiency in an ultra dense, rack optimized
form factor ServerWorks Grand Champion-LE chipset
2x1 interleaved memory, 200MHz DDR SDRAM Memory (PC2100 Registered SDRAM with Advanced ECC functionality)
1024 MB or 512 MB (depending on model) standard memory, expandable to 12 GB
HP Advanced Memory Protection
Two, full length 64-bit/100 MHz Non-Hot Pluggable PCI slots, one full length 64-bit/133 MHz Non-Hot Pluggable
Integrated Lights-Out Standard Management (iLO) on system board
Two NC7781 PCI-X Gigabit NICs (embedded)
Integrated Smart Array 5i Plus Controller (Ultra3) with 64-MB total memory on 5i Plus Memory Module
Battery-Backed Write Cache Enabler module on all 2P models (optional on 1P model)
Internal Hot Plug Drive Storage of up to 600 GB (2 x 300 GB 1" Ultra320 hard drives)
Redundant Cooling Zones for major subsystems (Memory, I/O, CPUs) assure 7x24 cooling
Toolless and virtually cable-less internal design
Rapid Deployment racking solution (rack rails and cable management)
Protected by HP Services and a worldwide network of resellers and service providers. Three-year Next Business Day, on-site
limited global warranty. Certain restrictions and exclusions apply. Pre-Failure Notification on processors, memory, and SCSI
hard drives.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 2
QuickSpecs
HP ProLiant DL560
Standard Features
Processor
One of the following
depending on Model
(2P) Intel Xeon Processor MP 3.0 GHz/4MB (Expandable to 4 processors)
(2P) Intel Xeon Processor MP 2.7 GHz/2MB (Expandable to 4 processors)
(1P) Intel Xeon Processor MP 2.2 GHz/2MB (Expandable to 4 processors)
(1P) Intel Xeon Processor MP 2.0 GHz/1MB (Expandable to 4 processors)
Cache Memory
One of the following
depending on Model
4MB Integrated Level 3 Cache
NOTE: 3.0 GHz Models only.
2MB Integrated Level 3 Cache
NOTE: 2.7 GHz and 2.2 GHz Models only.
1MB Integrated Level 3 Cache
NOTE: 2.0 GHz Models only.
Upgradability
Upgradable to quad processing
Chipset
ServerWorks Grand Champion-LE chipset
NOTE: For more information regarding ServerWorks, please see the following URL:
http://www.serverworks.com/products/overview.html.
Memory
One of the following
depending on Model
Type
200-MHz (DDR) SDRAM PC2100 Registered SDRAM Memory with Advanced
ECC functionality
Standard
1024 MB
Maximum
12 GB
NOTE: Advanced ECC Memory Technology protects the data even in the event of an entire SDRAM
component failure. Embedded in the chipset design, this feature allows the use of Industry-Standard
Registered DIMMs.
Network Controller
Two NC7781 PCI-X Gigabit NICs (embedded)
Expansion Slots
I/O (3 Total, 3 Available)
64-bit/100-MHz PCI
Non-Hot Plug
64-bit/133-MHz PCI-X
Non-Hot Plug
Manageability
PCI Voltage:
2 and 3
3.3 Volt only
1
3.3 Volt only
Integrated Lights-Out (iLO) Standard Management (ASIC on the System Board)
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 3
QuickSpecs
HP ProLiant DL560
Standard Features
Storage Controllers
Smart Array 5i Plus Controller, Ultra3 (supports RAID 0, 1, across internal hard disk drives) with 64 MB
of memory
64-MB total memory for code, transfer buffers, and read/write cache on the 5i Plus Memory
Module
Connector for Battery Backed Write Cache (BBWC) Enable
NOTE: The Smart Array 5i Plus Controller is integrated on the system board and is designed to support
the simplex drive cage. An external SCSI port is not available on the HP ProLiant DL560. External SCSI
solutions require the addition of a PCI or PCI-X option card.
Storage Data Protection
The Battery-Backed Write Cache (BBWC) Enabler protects up to 64-MB write cache memory from hard
boot, power, controller, or system board failures.
Standard on HP ProLiant DL560 2P Models, optional on 1P Models
Battery charge/life: Up to 72 hours/ 3 years
Transportable data protection
Increases overall controller performance
NOTE: Safely transport your write cache data to another HP ProLiant DL560 in the data center be
removing the BBWC Enabler and 5i Plus Memory Module simultaneously (connected by short cable).
Storage
Diskette Drive
Optical Drive
Hard Drives
Maximum Internal Storage
Hard Disk Drive
Backplane
1.44 MB Diskette Drive
24x IDE CD-ROM Drive (slimline) – ejectable for security and serviceability
None
600 GB (2 x 300 GB Ultra320 1" SCSI drives) (internal hot plug Ultra3 drive
cage)
Internal Wide Ultra3 backplane supports up to two 1" hard disk drives
Interfaces
Serial
Pointing Device (Mouse)
Graphics
Keyboard
Rear USB Ports
iLO Remote Management
Network RJ-45
USB 1.0
1
1
1
1
2
1
2
1
Graphics
Integrated 1280 x 1024, 16M color on PCI local bus, 8-MB of SDRAM video memory
Form Factor
Rack (2U = 3.5 inches), ships with sliding rails and cable management system
Space saving form factor (2U) provides space efficiencies while providing maximum deployment
flexibility
ProLiant Essentials
Foundation Pack
Software
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 4
QuickSpecs
HP ProLiant DL560
Standard Features
ProLiant Essentials
Foundation Pack
Software
HP Systems Insight
Manager
HP's new HP Systems Insight Manager (HP SIM) helps maximize system
uptime and performance and reduce system maintenance costs by providing
proactive notification of problems before those problems result in unplanned
downtime or reduced productivity. HP SIM are both easy to set up work with
the Insight Management Agents, integrated Lights-Out and Remote Insight
Lights-Out Edition, and Version Control Agents to deliver robust fault,
configuration, and asset management as well as remote administration. With
HP SIM customers will also be able to take advantage of role-based security;
the ability to manage ProLiant, Integrity, and HP 9000 systems; and plug-ins
for storage, client, printer, and power management as well as server rapid
deployment, performance management, and workload management. For
more details on HP SIM visit http://www.hp.com/go/hpsim.
SmartStart
SmartStart is a tool that simplifies server setup, providing a rapid way to
deploy reliable and consistent server configurations. For more information,
please visit the SmartStart Web site at http://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 6.20.
Management Agents
The Management Agents form the foundation for HP's Intelligent
Manageability strategy. They provide direct, browser-based access to indepth instrumentation built into HP servers, workstations, desktops, and
portables, and send alerts to Systems Insight Manager and other enterprise
management applications in case of subsystem or environmental failures.
For additional information about the Management Agents and other
management products from HP, please visit the management Web site at
http://www.hp.com/servers/manage.
Subscriber's Choice
Subscriber's Choice Driver and Support Alerts/Notifications is a web-based
email subscription service that provides automatic delivery of software and
driver change notifications for ProLiant products. Sign up at
http://www.hp.com/go/subscriberschoice
and customize your profile to receive various new alerts as they become
available, on a weekly or monthly basis.
ROMPaq, support
software, and
configuration utilities
The latest software, drivers, and firmware fully optimized and tested for your
ProLiant server and options available in SmartStart or downloadable from
Software and Drivers download pages, linked from the SmartStart website at
www.hp.com/servers/smartstart.
Survey Utility and
diagnostics utilities
The most advanced configuration analysis, reporting and troubleshooting
utilities used by HP and at your fingertips, available in SmartStart.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 5
QuickSpecs
HP ProLiant DL560
Standard Features
Optional ProLiant
Essentials Value Packs
Optional software offerings that selectively extend the functionality of an
Adaptive Infrastructure to address specific business problems and needs:
Rapid Deployment Pack - an automated solution for multi-server
deployment and provisioning, enabling companies to quickly and
easily adapt to changing business demands.
Workload Management Pack - provides easier management of
complex environments, improving overall server utilization and
enabling Windows® 2000 customers for the first time to confidently
deploy multiple applications on a single multiprocessor ProLiant
Server.
Integrated Lights-Out Advanced Pack - upgrades the Integrated LightsOut processor to full virtual presence and control with graphical
console and virtual media.
Performance Management Pack - a performance management
solution that identifies and explains hardware performance bottlenecks
on ProLiant servers and attached options enabling users to better
utilize their valuable resources.
Intelligent Networking Pack - detects and analyzes network bottlenecks
or broken network linkages and steers traffic to the optimum route
based on network conditions, plus it provides an extra layer of
protection. The virus throttle feature of the solution slows the
propagation of fast spreading virus
Vulnerability and Patch Management Pack - identifies and remediates
software security vulnerabilities due to missing patches as well
operating system configurations that can be exploited by viruses,
worms, and other blended threats
Virtual Machine Management Pack - provides central management
and control of virtual machines from Microsoft and VMware.
Integrated approach provides the ability to manage both physical and
virtual resources from a single management console.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to
http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product
QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL:
http://www.hp.com/servers/proliantessentials
Industry Standard
Compliance
ACPI 2.0 Compliant
PCI 2.2 Compliant
PXE Support
WOL Support
Physical Address Extension (PAE) Support
Microsoft® Logo certifications
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 6
QuickSpecs
HP ProLiant DL560
Standard Features
Intelligent Manageability Integrated Lights-Out (iLO) Standard Management
Virtual Text Remote Console
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
Integrated Lights-Out (iLO) Advanced Pack (supports Advanced features such as Graphical Remote
Console and Virtual Floppy - available as a separate option)
Automatic Server Recovery-2 (ASR-2)
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
ROM-Based Setup Utility (RBSU)
Integrated Management Log (IML)
Hot Spare Boot
NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will
automatically reboot and use the remaining good processor(s).
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Redundant/adaptive load balancing NIC Support
Availability
Standard Advanced ECC functionality detects and corrects single bit and specific multi-bit memory
errors (4bit and 8bit) while using industry standard registered DIMMS. Functionality is embedded
in the chipset design.
HP Advanced Memory Protection Technology – delivers unsurpassed memory protection and
server availability:
Online Spare Memory:
Offers a higher level of memory protection than Advanced ECC alone. If the number of
single-bit correctable errors on a bank exceeds the pre-defined error threshold, that bank
will fail over to the online spare bank without intervention or server interruption. The failed
memory can then be replaced at the user's convenience during a scheduled maintenance
window.
NOTE: All HP Advanced Memory Protection modes are user configurable through the ROM-Based
Setup Utility (RBSU) and viewable through Insight Manager 7 and the Integrated Management Log
(IML.).
Smart Array 5i Plus Controller with standard Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance. Up to 64MB
Battery Backed Write Cache protection available on 2P HP ProLiant DL560 models (BBWC
Enabler is optional on 1P model).
Redundant Cooling Zones across major server subsystems (Memory, I/O, CPU) provide 7x24
cooling. Each zone is independent of each other and is able to support N+1 redundancy, as
indicated below.
This zone configuration enables the server to withstand up to three fan failures, provided that they are
not within the same zone. Each fan is hot plug redundant and individually removable.
Up to two Hot Plug Ultra3 Drive Bays
Simplex SCSI Backplane
Dual Hot Plug Redundant Power Supplies (standard on 2P Models, one ships standard on 1P
Models)
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 7
QuickSpecs
HP ProLiant DL560
Standard Features
Serviceability
Innovative Diagnostic Lighting
LED display on front panel indicates power, internal health, external health, Unit ID light.
Tool-less, virtually cable-less interior design
Tool-less access to interior of server
Lift up hood access to processors and primary fans
Ejectable, slimline media drives (and CD-ROM standard with support for optional DVDROM drives) is removable without the use of tools. Also has fixed floppy drive.
PCI Card Guides locks full length PCI cards in place during transit
Up to ten individually removable fans connect without cables to the system board
Processor/VRM Retention mechanism securely locks both processor and VRM into their
respective sockets
Tool-less removal of system board
Quick Deploy Rails
Tool-less design "snap in" rail
Security
Power-on password
Keyboard password
Diskette drive control
Diskette boot control
Network Server Mode
Security Provision
Serial interface control
Administrator's password
Disk configuration lock
Hot plug access security
Removable Diskette drive
Removable CD-ROM drive
UPS and PDU Power
Cord Matrix
Please see the UPS and PDU cable matrix that lists cable descriptions, requirements, and specifications
for UPS and PDU units:
ftp://ftp.compaq.com/pub/products/servers/ProLiantstorage/power-protection/powercordmatrix.pdf.
Power Supply
550-Watt (low line or high line) Hot Plug Power Supply
NOTE: One 550-Watt Hot Plug Power Supply ships standard with 1P Models (optional Redundant Hot
Plug Power Supply Option Kit).
NOTE: Two 550-Watt Hot Plug Power Supplies ship standard with 2P Models.
System Fans
Standard
5 Hot plug, redundant fans on 1P models (individually removable)
Maximum
10 Hot plug, redundant fans on 2P models (individually removable)
Redundant Cooling Zones across major server subsystems (Memory, I/O, CPU) provide 7x24
cooling. Each zone is independent of each other and is able to support n+ 1 redundancy, as
indicated below:
PCI-X expansion zone is 1+ 1 redundant (fans 1 and 2)
System can run fully loaded with five fans. This zone configuration enables the server to withstand
up to three fan failures, provided that they are not within the same zone. Each fan is hot plug
redundant and individually removable.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 8
QuickSpecs
HP ProLiant DL560
Standard Features
Required Cabling
For required cabling information, refer to the HP Web site at
http://h18000.www1.hp.com/products/servers/proliantDL560/.
OS Support
Microsoft Windows 2000
Windows Server 2003
Novell NetWare
LINUX (Red Hat, SuSE)
UnitedLinux
VMware Virtualization Software
NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS
Support Matrix at: http://www.hp.com/go/supportos
NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant DL560, please see:
http://www.HP.com/support/files/server/us/index.html.
NOTE: For a more complete and up-to-date information on Linux support, please visit HP Linux website
at http://h18000.www1.hp.com/products/servers/linux/hpLinuxcert.html
NOTE: For more complete and up-to-date information on how to buy server operating systems from HP
please visit the OS product site at: http://h18004.www1.hp.com/products/servers/software/OEM.html
NOTE: For more information on HP's Certified and Supported ProLiant Servers, please visit the VMware
Server Support Matrix at:
http://h18004.www1.hp.com/products/servers/software/vmware/hpvmwarecert.html.
Rack Airflow
Requirements
Rack 10000 series Cabinets The increasing power of new high-performance processor technology
requires increased cooling efficiency for rack-mounted servers. The 10000 Series Racks provide
enhanced airflow for maximum cooling, allowing these racks to be fully loaded with servers using the
latest processors.
CAUTION: If a third-party rack is used, observe the following additional requirements to ensure
adequate airflow and to prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you
must allow 830 square inches (5,350 sq cm) of hole evenly distributed from top to bottom
to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack
must be a minimum of 2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This
arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling
that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD
provided with the server, or to the server documentation located in the Support section at the following
URL: http://www5.HP.com/products/servers/proliantdl560/index.html.
Rack Mounting
Requirements
Tool-free support for racks with square mounting holes (including Compaq/HP 7000, 9000, 10000 and
H9 series), with an adjustment range of 24"– 36".
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 9
QuickSpecs
HP ProLiant DL560
Standard Features
Factory Express Portfolio
for Servers and Storage
HP Factory Express offers configuration, customization, integration and deployment services for HP
servers and storage products. Customers can choose how their factory solutions are built, tested,
integrated, shipped and deployed.
Factory Express offers service packages for simple configuration, racking, installation, complex
configuration and design services as well as individual factory services, such as image loading, asset
tagging, and custom packaging. HP products supported through Factory Express include a wide array of
servers and storage: HP Integrity, HP ProLiant, HP ProLiant Server Blades, HP BladeSystem, HP 9000
servers as well as the MSA1000, VA7xxx, EVA, XP, rackable tape libraries and configurable network
switches.
For more information on Factory Express services for your specific server model please contact your sales
representative or go to http://www.hp.com/go/factory-express.
Custom Builder
Please see the Enterprise Configurator for configuration assistance at:
http://www.hp.com/products/configurator.
Service and Support
This product is covered by a global limited warranty and supported by HP Services and a worldwide
network of resellers and service providers. Hardware diagnostic support and repair is available for three
years from date of purchase. Support for software and initial setup is available for 90 days from date of
purchase. Additional support may be covered under the warranty or available for an additional fee.
Enhancements to warranty services are available through HP Care Pack services or customized service
agreements.
NOTE: Limited warranty includes 3 year parts, 3 year labor, 3-year on-site support.
Care Pack services provide a range of life cycle support options that let you choose the service levels that
meet your business requirements, from basic to mission-critical.
A full range of HP Care Pack hardware and software services are available including:
Installation and start up
Education courses
Extended onsite hardware coverage hours from same business day 13 hours, 5 day to 24 hours, 7
days call window with options including 4-hour response or 6-hour Call To Repair
Comprehensive range of software technical support for Microsoft, Linux, ProLiant Essentials and
VMWare-based IT solutions helping to deliver high level of application availability. Response times
range from 30 mins for critical problems to 2 hours.
System Management, Performance Services and Mission Critical Support Solution
HP Care Pack Services include HP branded hardware options qualified for the server, purchased at the
same time or afterwards, internal to the enclosure, as well as 22" and smaller external monitors and
tower UPS options up to 3KVA. 22" and smaller external monitors will be covered at the same service
level and coverage period as the server. For servers or storage systems installed within a rack, service
also covers all HP qualified rack options installed within the same rack.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 10
QuickSpecs
HP ProLiant DL560
Standard Features
NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or
resellers or visit our worldwide Web site on the internet at: http://www.hp.com/hps/carepack
NOTE:For
more complete information on HP Services offerings, customers and resellers, please visit us
NOTE:
at: http://www.hp.com/hps
NOTE: Additional information regarding worldwide limited warranty and technical support is available
at: http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 11
QuickSpecs
HP ProLiant DL560
Models
DL560R01 X3.0GHz4MB, 1024MB (2P)
346921-xx1
Processor(s)
Cache Memory
Memory
Network Controller
Storage Controller
Manageability
Hard Drives
Internal Storage
Power Supply
Optical Drive
Diskette Drive
Form Factor
DL560R01 X2.7-2MB,
1024MB (2P)
346920-xx1
Processor(s)
Cache Memory
Memory
Network Controller
Storage Controller
Manageability
Hard Drives
Internal Storage
Power Supply
Optical Drive
Diskette Drive
Form Factor
DA - 11595
(2) Intel Xeon Processors MP at 3.0 GHz standard (up to 4 supported)
4MB Integrated Level 3 Cache
1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM
Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum)
Two NC7781 PCI-X Gigabit NICs (embedded)
Smart Array 5i Plus Controller (Ultra3) with Battery-Backed Write Cache
Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
None ship standard
293.6 GB maximum (with optional hard drives)
Two 550W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE slimline CD-ROM Drive
1.44 MB Diskette Drive
Rack 2U
(2) Intel Xeon Processors MP at 2.7 GHz standard (up to 4 supported)
2MB Integrated Level 3 Cache
1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM
Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum)
Two NC7781 PCI-X Gigabit NICs (embedded)
Smart Array 5i Plus Controller (Ultra3) with Battery-Backed Write Cache
Enabler (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
None ship standard
293.6 GB maximum (with optional hard drives)
Two 550W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE slimline CD-ROM Drive
1.44 MB Diskette Drive
Rack 2U
Worldwide — Version 43 — November 7, 2005
Page 12
QuickSpecs
HP ProLiant DL560
Models
DL560R01 X2.2-2MB,
1024MB (1P)
346919-xx1
Processor(s)
Cache Memory
Memory
Network Controller
Storage Controller
Manageability
Hard Drives
Internal Storage
Power Supply
Optical Drive
Diskette Drive
Form Factor
DL560R01 X2.0-1MB,
1024MB (1P)
246638-xx2
Processor(s)
Cache Memory
Memory
Network Controller
Storage Controller
Manageability
Hard Drives
Internal Storage
Power Supply
Optical Drive
Diskette Drive
Form Factor
Country Code Key
XX=00
XX=01
XX=03
XX=20
XX=29
XX=37
XX=42
XX=AA
(1) Intel Xeon Processor MP at 2.2 GHz standard (up to 4 supported)
2MB Integrated Level 3 Cache
1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM
Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum)
Two NC7781 PCI-X Gigabit NICs (embedded)
Smart Array 5i Plus Controller (Ultra3) (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
None ship standard
293.6 GB maximum (with optional hard drives)
One 550W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE slimline CD-ROM Drive
1.44 MB Diskette Drive
Rack 2U
(1) Intel Xeon Processor MP at 2.0 GHz standard (up to 4 supported)
1MB Integrated Level 3 Cache
1024 MB 200-MHz (DDR) SDRAM (PC2100-MHz Registered SDRAM
Memory with Advanced ECC functionality) (Standard) to 12 GB (Maximum)
Two NC7781 PCI-X Gigabit NICs (embedded)
Smart Array 5i Plus Controller (Ultra3) (integrated on system board)
Integrated Lights-Out (iLO) Standard management (integrated on system
board)
None ship standard
293.6 GB maximum (with optional hard drives)
One 550W Hot Plug Redundant Power Supplies (low line or high line)
24x IDE slimline CD-ROM Drive
1.44 MB Diskette Drive
Rack 2U
US
Australia
UK
Brazil
EURO
APD
Int'l, Europe, Germany, France
PRC
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 13
QuickSpecs
HP ProLiant DL560
Options
ProLiant Essentials
Value Pack Software
ProLiant Essentials Integrated Lights-Out Advanced Pack
ProLiant Essentials Integrated Lights-Out Advanced Pack, 1 server
Featuring: sophisticated virtual administration features for ultimate control of servers
in the data centers and remote sites.
NOTE: For additional ProLiant Integrated Light-Out Advanced Pack License Kits
please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11052_div/11052_div.HTML
ProLiant Essentials Intelligent Networking Pack
ProLiant Essentials Intelligent Networking Pack - Windows Edition, Single Server
License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
NOTE: For additional ProLiant Intelligent Networking Pack - Windows License Kits
please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12062_div/12062_div.HTML
ProLiant Essentials Intelligent Networking Pack - Linux Edition, Single Server License
NOTE: For additional ProLiant Intelligent Networking Pack - Linux License Kits please
see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12327_div/12327_div.HTML
ProLiant Essentials Performance Management Pack
ProLiant Essentials Performance Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license
activation key, HP Management CD and documentation.
NOTE: The most recent version of the software can always be downloaded at
http://www.hp.com/products/pmp.
NOTE: For additional ProLiant Performance Management Pack License Kits please
see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11925_div/11925_div.HTML
ProLiant Essentials Rapid Deployment Pack Windows Edition and Linux Edition
Release
Rapid Deployment Pack, Single-Server License
NOTE: This license allows 1 server to be deployed and managed via RDP.
Rapid Deployment Pack, Single-Server License (Japan)
NOTE: This license allows 1 server to be deployed and managed via RDP.
NOTE: For additional ProLiant Essentials Rapid Deployment Pack License Kits please
see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11053_div/11053_div.HTML
http://h18000.www1.hp.com/products/quickspecs/11713_div/11713_div.HTML
ProLiant Essentials Workload Management Pack
ProLiant Essentials Workload Management Pack, Single Server License
NOTE: For additional ProLiant Workload Management Pack License Kits please see
the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11452_div/11452_div.HTML
ProLiant Essentials Virtualization Management Software
ProLiant Essentials Virtual Machine Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
DA - 11595
Worldwide — Version 43 — November 7, 2005
263825-B21
372906-B21
397004-B21
306696-B21
267196-B21
267196-291
303284-B21
372214-B21
Page 14
QuickSpecs
HP ProLiant DL560
Options
ProLiant Essentials Server Migration Pack, Single-Migration License
NOTE: Contains one license, enabling 1 server migration, with a unique license
activation key and documentation.
NOTE: This license allows 1 server to be migrated from a physical server to a virtual
machine. Or this license can be used to migrate a virtual machine from one
virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware
ESX or Microsoft Virtual Server 2005.
NOTE: For additional ProLiant Essentials Virtualization Management Software License
Kits please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12328_div/12328_div.HTML
ProLiant Essentials Vulnerability and Patch Management Pack
ProLiant Essentials Vulnerability and Patch Management Pack, Single-Server License
NOTE: For use with a single server. Contains one license with a unique license
activation key and documentation.
375345-B21
371645-B21
NOTE: For additional ProLiant Vulnerability and Patch Management Pack License
Kits, please see the QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/12111_div/12111_div.HTML
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials
Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various
ProLiant Essentials Value Pack product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the
following URL: http://www.hp.com/servers/proliantessentials.
Processor
Intel Xeon MP X3.0/4MB Processor Option Kit
Intel Xeon MP X2.70/2MB Processor Option Kit
Intel Xeon MP X2.20/2MB Processor Option Kit
Intel Xeon MP X2.80/2MB Processor Option Kit
Intel Xeon MP X2.50/1MB Processor Option Kit
Intel Xeon MP X2.0/1MB Processor Option Kit
346990-B21
346989-B21
346988-B21
331004-B21
331003-B21
331002-B21
Memory (DIMMs)
4 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
2 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
1 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
512 MB of PC2100 ECC DDR DIMM Memory Kit (2 x 256 MB)
300682-B21
300680-B21
300679-B21
300678-B21
Optical Drives
Slimline CD-RW/DVD-ROM Combo Drive Option Kit
Slimline DVD-ROM Drive (8X/24X) Option Kit (Servers)
HP DVD+R/RW 8X Slim
331903-B21
264007-B21
383975-B21
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 15
QuickSpecs
HP ProLiant DL560
Options
Hard Drives
Storage Controller
Ultra320 SCSI - Universal Hot Plug
300-GB 10,000 rpm U320 Universal Hard Drive (1")
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
146.8-GB 15,000 rpm U320 SCSI Hard Drive (1")
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3
speeds. U320 drives require an optional U320 Smart Array Controller or U320 SCSI
HBA to support U320 transfer rates.
NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as
capacity, height, width, interface, transfer rate, seek time, physical configuration, and
operating temperature:
U320 Hard Drive QS:
http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.HTML
(North America)
350964-B22
286716-B22
286714-B22
347708-B22
286778-B22
286776-B22
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
256-MB Battery-Backed Cache Module
NOTE: This 256-MB Battery-Backed Cache Module supports the Smart Array 5300
series controllers, HP StorageWorks Modular Smart Array 1000 and the HP
StorageWorks Modular Array 500.
256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400
NOTE: This 256-MB Battery-Backed Cache Module upgrade kit supports the Smart
Array 6400 series controller only.
Battery-Backed Write Cache Enabler Option Kit
NOTE: This Battery-Backed Write Cache Enable Option Kit (PN 255514-xx1) is
optional for the HP ProLiant DL560 1P Model only.
Battery-Backed Write Cache Enabler Option Kit (Japan)
NOTE:
NOTE This Battery-Backed Write Cache Enable Option Kit (PN 255514-xx1) is
optional for the HP ProLiant DL560 1P Model only.
128MB Battery-Backed Cache Enabler
NOTE: This 128MB BBWC supports the Smart Array 641 Controller and Smart Array
642 Controller.
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
Ultra320 Expansion Module for SA-6402
273915-B21
273914-B21
291966-B21
291967-B21
254786-B21
DA - 11595
Worldwide — Version 43 — November 7, 2005
273913-B21
255514-B21
255514-291
351580-B21
268351-B21
284688-B21
273911-B21
Page 16
QuickSpecs
HP ProLiant DL560
Options
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical
Specifications such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols
supported, SCSI Peak Data Transfer Rate, Channels, SCSI Ports, Drives supported,
Cache, RAID support, and additional information:
http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.HTML
(Smart Array 6400 Series)
http://h18000.www1.hp.com/products/quickspecs/12067_div/12067_div.HTML
(Smart Array 641)
http://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.HTML
(Smart Array 642)
http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.HTML
(SCSI Adapter)
http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.HTML
(U320 Adapter)
Communications
HP NC310F PCI-X 1000SX Gigabit Server Adapter
HP NC1020 PCI 1000T Gigabit Server Adapter
HP NC6170 PCI-X Dual Port 1000SX Gigabit Server Adapter
HP NC7170 PCI-X Dual Port 1000T Gigabit Server Adapter
HP NC7771 PCI-X 1000T Gigabit Server Adapter
NOTE: Any NIC on the option list can be used for redundancy with the embedded
NC7781 Network Controller
368169-B21
353377-B21
313879-B21
313881-B21
290563-B21
Redundant Options
Hot Plug Redundant Power Supply Option Kit
Hot Plug Redundant Power Supply Option Kit (EMEA)
Hot Plug Redundant Fan Option Kit
267555-001
267555-B21
288635-B21
Management Options
Remote Insight Lights-Out Edition II (NA, LA)
Remote Insight Lights-Out Edition II (EMEA)
Remote Insight Lights-Out Edition II (ROW)
227251-001
227251-021
227251-371
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 17
QuickSpecs
HP ProLiant DL560
Options
Tape Drives
NOTE: For the complete listing of Tape Drive offerings for this server, please visit:
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For recommended tape drive offerings for this ProLiant server see the following:
Hot Plug Tape Drives
HP StorageWorks DAT 72 Tape Drive, Internal Hot-Plug (Carbon)
USB Tape Drives
HP StorageWorks DAT 72 USB External Tape Drive (Carbonite)
External and Rack-Mount Ultrium Tape Drives
HP StorageWorks Ultrium 232 Tape Drive, Internal (Carbonite)
NOTE: No internal tape drives fit inside this HP ProLiant server (except hot plug tape).
The internal drive shown here is for the 1U and 3U Rack-mount Kit.
HP StorageWorks Ultrium 232 Tape Drive, External (Carbonite)
HP StorageWorks Ultrium 448 Tape Drive, External (Carbonite)
HP StorageWorks Ultrium 448 Rack-mount (Carbonite) - Single drive installed in a 1U
rack-mount kit
HP StorageWorks Ultrium 960 Tape Drive , External (Carbonite)
HP StorageWorks 3U Rack-Mount Kit with one Ultrium 960 drive
NOTE: Please see the HP StorageWorks Ultrium Tape Drive QuickSpecs for
additional options such as controllers, media, and other related items:
http://h18006.www1.hp.com/products/quickspecs/11739_div/11739_div.html
(Worldwide)
http://h18006.www1.hp.com/products/quickspecs/11739_na/11739_na.html
(North America)
For an up-to-date listing of the latest O/S and software support details for HP Ultrium
tape drives, please visit: http://www.hp.com/go/connect.
Rack-Mount Tape Drive Enclosures
HP StorageWorks 1U Rack-Mount Kit
NOTE: The 1U Rack-mount Kit can support up to 2 half-height tape drives and is
compatible with multiple Single-Ended and LVD SCSI tape drives including DAT 24,
DAT40, DAT72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232, and Ultrium 448
tape drives.
1U USB Cable Option Kit
NOTE: Converts a 1U SCSI rack-mount kit to a USB interface to support the USB tape
drives.
HP StorageWorks 3U Rack-Mount Kit
NOTE: The 3U Rack-Mount Kit can support up to 2 full-height or 4 half-height tape
drives and compatible with multiple Single-Ended and LVD SCSI tape drives including
DAT 24, DAT 40, DAT 72, DAT 72X6 Autoloader, DLT VS80, DLT VS160, SDLT 320,
SDLT 600, Ultrium 215, Ultrium 232, Ultrium 230, Ultrium 448, Ultrium 460, and
Ultrium 960 tape drives.
NOTE: Please see the Rack-Mount Tape Drive Kits QuickSpecs for additional
information regarding these kits:
http://h18000.www1.hp.com/products/quickspecs/10854_div/10854_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/10854_na/10854_na.HTML
(North America)
DA - 11595
Worldwide — Version 43 — November 7, 2005
Q1529A
DW027A
DW064A
DW065A
DW017A
DW028A
Q1539A
Q1595A
A7445A
396114-B21
274338-B21
Page 18
QuickSpecs
HP ProLiant DL560
Options
Tape Autoloaders
Tape Libraries
DAT Autoloader
HP StorageWorks DAT 72x6 External Autoloader
NOTE: Please see the DAT Tape Autoloader QuickSpecs for additional options such
as host bus adapters, controllers and media:
http://h18000.www1.hp.com/products/quickspecs/11985_div/11985_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11985_na/11985_na.HTML
(North America)
HP StorageWorks 1/8 Tape Autoloader
1/8 Ultrium 232 Tape Autoloader, Tabletop
1/8 Ultrium 460 Tape Autoloader, Tabletop
1/8 Ultrium 960 Tape Autoloader, Tabletop
1/8 Tape Autoloader Rackmount Kit
NOTE: Required to install the unit in a standard 19-inch rack; includes rails and
rackmount instructions
NOTE: Required to install the 1/8 tape autoloader in a standard 19-inch rack
NOTE: Please reference the 1/8 Tape Autoloader QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP StorageWorks SSL1016 Tape Autoloader
SSL1016 Ultrium 460 Tape Autoloader
SSL1016 SDLT 320 Tape Autoloader
NOTE: Please reference the SSL1016 Tape Autoloader QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs
HP StorageWorks MSL6000 Tape Library
Ultrium 960 technology
MSL6030, 1 drive, 30 slots, Ultrium 960
MSL6030, 1 drive, 30 slots, Ultrium 960, with embedded FC router
MSL6030, 2 drive, 60 slots, Ultrium 960
MSL6030, 2 drive, 60 slots, Ultrium 960, with embedded FC router
Ultrium 460 technology
MSL6030, 1 drive, 30 slots, Ultrium 460
MSL6030, 1 drive, 30 slots, Ultrium 460, with embedded FC router
MSL6030, 2 drive, 60 slots, Ultrium 460
MSL6030, 2 drive, 60 slots, Ultrium 460, with embedded FC router
NOTE: Please reference the MSL6000 Tape Library QuickSpecs at
http://www.hp.com/go/automation for additional information needed to create a
complete solution; reference current compatibility information at
http://www.hp.com/go/ebs.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Q1567A
AF202A
AA927A
AF204A
C9268R
330821-B21
330816-B21
AD606A
AD608A
AD607A
AD609A
AD598A
AD600A
AD599A
AD601A
Page 19
QuickSpecs
HP ProLiant DL560
Options
Magneto-Optical
Jukeboxes
HP StorageWorks 9.1 GB Optical Jukeboxes
600mx, 4 drive, 64 slot jukebox
1200mx, 4 drive, up to 128 slots
2200mx, 6 drive, up to 238 slots
NOTE: Please see the HP StorageWorks Magneto-Optical Products data sheet for a
complete listing of available jukeboxes at:
http://www.hp.com/products1/storage/products/archivalprod/brochures/
MO_family_pb.pdf
NOTE: Please reference the Magneto-Optical Jukebox data sheets at
http://www.hp.com/go/optical for additional information needed to create a
complete solution.
C1160M
C1104M
C1107M
Ultra Density Optical
Jukeboxes
1900ux, 4 drive, 64 slot jukebox
3800ux, 4 drive, 128 slot jukebox
7100ux, 6 drive, 238 slot jukebox
NOTE: Please see the HP StorageWorks Ultra Density Optical Jukeboxes QuickSpecs
for a complete listing of available jukeboxes at:
http://h18006.www1.hp.com/products/quickspecs/11944_div/11944_div.html
NOTE: Please reference the Ultra Density Optical Jukebox QuickSpecs at
http://www.hp.com/go/optical for additional information needed to create a
complete solution
AA966A
AA969A
AA971A
Cluster Options
ProLiant Cluster Starter Kit
NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see
the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11935_div/11935_div.html
(Worldwide)
ProLiant Cluster Kit with OpenView Storage Mirroring
NOTE: For additional information regarding the ProLiant Cluster Kit with OpenView
Storage Mirroring please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11934_na/11934_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11934_div/11934_div.html
(Worldwide)
HP HA/F200 for Entry SAN Cluster
HP HA/F200 for Entry SAN Cluster (Japan)
NOTE: For additional information regarding the ProLiant Cluster for Entry Level SAN
please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11932_na/11932_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11932_div/11932_div.html
(Worldwide)
ProLiant Cluster HA/F500 for the Enterprise SAN
DA - 11595
Worldwide — Version 43 — November 7, 2005
364023-B21
364025-B21
364026-B22
364026-292
364024-B21
Page 20
QuickSpecs
HP ProLiant DL560
Options
NOTE: For additional information regarding the ProLiant Cluster HA/F500 for
Enterprise SAN please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11933_na/11933_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11933_div/11933_div.html
(Worldwide)
HP Serviceguard for Linux ProLiant Cluster A.11.15 for SUSE SLES 8 / UnitedLinux 1.0
and Red Hat EL 3 (2 node license cluster kit)
HP Serviceguard for Linux ProLiant Cluster A.11.16 for SUSE SLES 9 and Red Hat EL
& 4 (2 node license cluster kit)
HP Serviceguard for Linux License A.11.15 for SUSE SLES 8 / UnitedLinux 1.0 and
Red Hat EL 3 (single license version)
HP Serviceguard for Linux A.11.16 for SUSE SLES9 and Red Hat EL 3 & 4 (single
license version)
NOTE: For additional information regarding the HP Serviceguard for Linux License,
please see the following QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11518_na/11518_na.html
(North America)
http://h18000.www1.hp.com/products/quickspecs/11518_div/11518_div.html
(Worldwide)
HP StorageWorks
Modular Smart Array 20
HP StorageWorks
Modular Smart Array 30
305199-B24
305199-B26
307754-B24
307754-B26
HP StorageWorks Modular Smart Array 20
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies.
HP StorageWorks Modular Smart Array 20 Starter Kit
NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies. Includes Smart Array 6402/128 Controller.
NOTE: The Modular Smart Array Enclosure 20 Family supports the SATA 1.5Gb/s 1"
Hot Plug Hard Drives.
335921-B21
HP StorageWorks Modular Smart Array 30 SB
NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies
HP StorageWorks Modular Smart Array 30 DB
NOTE: Rack-mountable 14 drive enclosure with dual bus, redundant power supplies
NOTE: The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,
Ultra320 1" Hot Plug Hard Drives.
302969-B21
HP StorageWorks
HP StorageWorks Modular Smart Array 500 Generation 2
Modular Smart Array 500 NOTE: Please see the Modular Smart Array 500 Generation 2 QuickSpecs for
additional information including configuration steps and additional options needed
for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11956_na/11956_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11956_div/11956_div.HTML
(Worldwide)
DA - 11595
Worldwide — Version 43 — November 7, 2005
366172-B21
302970-B21
335880-B21
Page 21
QuickSpecs
HP ProLiant DL560
Options
HP StorageWorks
Modular Smart Array
1000
HP StorageWorks Modular Smart Array 1000
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options
and configuration information at
http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML
(Worldwide)
HP StorageWorks
Modular Smart Array
1500 cs
Modular Smart Array 1500 Controller Shelf
NOTE: Please see the StorageWorks Modular SAN Array 1500 cs QuickSpecs for
additional options and configuration information at:
http://www.hp.com/go/MSA1500cs
AA986A
StorageWorks Options
StorageWorks SAN Switch 2/16
StorageWorks SAN Switch 2/16-EL Upgrade Kit
StorageWorks Director 2/64
NOTE: Please see the StorageWorks Director 2/64 QuickSpecs for additional
information:
http://h18000.www1.hp.com/products/quickspecs/11003_na/11003_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11003_div/11003_div.HTML
(Worldwide)
322118-B21
325889-B21
286809-B21
Uninterruptible Power
Systems – Rack
HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA)
HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int’l)
HP UPS R1500 XR (1500VA, 1340 Watt), Low Voltage (Japan)
HP UPS R3000 XR (2880VA, 2700 Watt), Low Voltage (NA)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (NA)
HP UPS R3000 XR (2400VA, 2250 Watt), Low Voltage (Japan)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Japan)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (Int’l - detachable cord)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A IEC309 Plug)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A CEE 7/7 SCHUKO
Plug)
HP UPS R3000 XR (3000VA, 2700 Watt), High Voltage (16A BS-546 Plug)
HP UPS R5500 XR, (5000VA, 4500 Watt), High Voltage (NA/Jpn)
HP UPS R5500 XR, (6000VA, 5400 Watt), High Voltage (Int'l)
UPS R12000 XR N+x (200-240V) (WW-hardwired)
NOTE: The UPS R12000 XR has a hardwired input and output connection.
204404-001
204404-B31
204404-291
192186-001
192186-002
192186-291
192186-292
192186-B31
192186-B32
192186-B33
DA - 11595
Worldwide — Version 43 — November 7, 2005
201723-B22
192186-AR1
326529-D71
326529-B31
207552-B22
Page 22
QuickSpecs
HP ProLiant DL560
Options
HP Power Distribution
Unit with Power
Monitoring
HP Power Distribution Unit with Power Monitoring Model S2324 - dual input, 3
phase, 24A (NA/JPN)
HP Power Distribution Unit with Power Monitoring Model S1324 - single input, 3
phase, 24A (NA/JPN)
HP Power Distribution Unit with Power Monitoring Model S2140 - dual input, 1
phase, 40A (NA/JPN)
HP Power Distribution Unit with Power Monitoring Model S1140 - single input, 1
phase, 40A (NA/JPN)
HP Power Distribution Unit with Power Monitoring Model S2316 - dual input, 3
phase, 16A (INTL)
HP Power Distribution Unit with Power Monitoring Model S1316 - single input, 3
phase, 16A (INTL)
HP Power Distribution Unit with Power Monitoring Model S2132 - dual input, 1
phase, 32A (INTL)
HP Power Distribution Unit with Power Monitoring Model S1132 - single input, 1
phase, 32A (INTL)
370959-D71
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
(NA, Japan)
NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of
the UPS R3000 XR.
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
(NA, Japan)
HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC)
(Int’l)
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
(WW)
NOTE: This mPDU (252663-B21), 40A model has a hardwired input.
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
(WW)
NOTE: This PDU has a detachable input power cord and allows for adaptability to
country specific power requirements. This model may also be used with the high volt
UPSs R3000 XR and R6000 For North America, need to order cable PN 340653-001
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U
Modular PDUs) QuickSpecs for additional options including shorter jumper cables
and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.HTML
(Worldwide)
252663-D71
HP Monitored Power
Distribution Unit
HP PDU with Power Monitoring, Model S1348 - single input, 3-phase, 60A (NA/JPN)
HP PDU with Power Monitoring, Model S1332 - single input, 3-phase, 32A (INTL)
AF916A
AF917A
USB Options
USB 2-Button Optical Scroll Mouse (Carbonite/Silver)
USB 1.44-MB External Diskette Drive (Carbonite)
DC172B
DC141B
Modular Power
Distribution Units 1U/0U
(Up to 32 outlets)
NOTE: 1U/0U mounting
brackets shipped with
the unit (optimized for
10000 and 9000 series
racks).
DA - 11595
Worldwide — Version 43 — November 7, 2005
370960-D71
370961-D71
370962-D71
370963-B31
370964-B31
370965-B31
370966-B31
252663-D72
252663-B31
252663-B21
252663-B24
Page 23
QuickSpecs
HP ProLiant DL560
Options
Third Party Rack Kit
Rack Adapter Kit
NOTE: This kit allows HP rack servers to fit in racks that are 24" wide.
332815-B21
HP Rack 10000 Series
(Graphite Metallic)
10642 (42U) Infrastructure Rack (Low Voltage)
10642 (42U) Infrastructure Rack (High Voltage)
HP Rack S10614 (14U) Rack Cabinet – Shock Pallet
HP Rack 10842 (42U, 800mm wide) – Pallet
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
HP Rack 10647 (47U) – Pallet
HP Rack 10647 (47U) – Crated
HP Rack 10642 (42U) – Pallet
HP Rack 10642 (42U) – Shock Pallet
HP Rack 10642 (42U) – Crated
HP Rack 10636 (36U) – Pallet
HP Rack 10636 (36U) – Shock Pallet
HP Rack 10636 (36U) – Crated
HP Rack 10622 (22U) – Pallet
HP Rack 10622 (22U) – Shock Pallet
HP Rack 10622 (22U) – Crated
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
NOTE
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems,
VARs and Channels)
-B23 (crated) used for air shipments of empty racks
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as
NOTE
height, width, depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML
(North America)
NOTE: For additional information regarding Rack Cabinets, please see the following
URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rackoptions/index.html.
379006-001
379005-001
292302-B22
257415-B21
257415-B22
245160-B21
245160-B23
245161-B21
245161-B22
245161-B23
245162-B21
245162-B22
245162-B23
245163-B21
245163-B22
245163-B23
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 24
QuickSpecs
HP ProLiant DL560
Options
Rack Options for HP
Rack 10000 Series
HP Rack Light Kit (Neon)
HP Rack Plinth Kit (Carbon)
42U Side Panel – Graphite Metallic
36U Side Panel – Graphite Metallic
47U Side Panel – Graphite Metallic
TFT7210R Rack Mounted 17" Monitor
NOTE: For a complete list of Monitors please view the following URL:
http://h18004.www1.hp.com/products/monitors/.
TFT5600 Rack Keyboard Monitor
NOTE: For a complete list of Monitors please view the following URL:
http://h18004.www1.hp.com/products/monitors/.
1U Rack Keyboard & Drawer (Carbon)
Country Code Key (for TFT5600 Rack Keyboard Monitor (PN 221546-xx1 and for 1U
Rack Keyboard & Drawer (PN 257054-xx1)
XX = 001
XX = 031
XX = 041
XX = 051
XX = 061
XX = 071
XX = 081
US
UK
Germany
France
Italy
Spain
Denmark
XX = 091
XX = 101
XX = 111
XX = 131
XX = 181
XX = 291
XX = B31
361589-B21
251960-B21
246099-B21
246102-B21
255486-B21
348373-B21
221546-xx1
257054-xx1
Norway
Sweden/Finland
Switzerland
Portugal
Belgium
Japan
International
NOTE: For additional information regarding Rack Options, please see the following
URL: http://h18000.www1.hp.com/products/servers/proliantstorage/rackoptions/index.html.
HP KVM Switch Options IP Console Switch Box (KVM/IP), 3 x 1 x 16
IP Console Switch Box (KVM/IP), 1 x 1 x 16
Server Console Switch (KVM), 0 x 1 x 8 port
Server Console Switch (KVM), 0 x 2 x 16 port
PS/2 Interface Adapter, 1 pack
PS/2 Interface Adapter, 8 pack
USB Interface Adapter, 1 pack
Serial Interface adapter - 1 Pack with power supply
NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches.
Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm.
HP 1x 4 USB/PS2 KVM Switch, TT (NA/JPN)
HP 1x 4 USB/PS2 KVM Switch, TT (AU/NZ)
HP 1x 4 USB/PS2 KVM Switch, TT (UK)
HP 1x 4 USB/PS2 KVM Switch, TT (EU)
HP 1x 4 USB/PS2 KVM Switch, RM (ALL)
HP PS2 KVM Cable with audio, 6', 2-pack
HP USB KVM Cable with audio, 6', 2-pack
NOTE: For additional information regarding KVM switches, Serial Console servers,
rack mount monitors, keyboards and all related options please see the following URL:
http://www.hp.com/go/kvm.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 25
QuickSpecs
HP ProLiant DL560
Options
HP Serial Console Server HP 16 Port Serial Console Server (worldwide)
Options
HP 48 Port Serial Console Server (worldwide)
Serial Adapter, RJ45-DB9 DCE Female, 1 Pack
Serial Adapter, RJ45-DB9 DCE Female, 8 Pack
NOTE: Cat5e cables are required to connect Serial Adapters to Serial Console
Servers. Additional Serial Adapters and Cat5e cables can be found at the following
URL: http://www.hp.com/go/kvm.
NOTE: For additional information regarding KVM switches, Serial Console servers,
rack mount monitors, keyboards and all related options please see the following URL:
http://www.hp.com/go/kvm.
Rack Options for Third
party Cabinet Racks
Round hole rack cabinet rail kit
NOTE: Support for racks with round mounting holes (include HP Rack System /E and
HP Systems) with and adjustment range of 24 inches to 36 inches (60.96 cm to 91.44
cm).
Service and Support
Hardware Services On-site Service
Offerings (HP Care Pack
4-Hour On-site Service, 5-Day x 13-Hour Coverage, 3 Years, Electronic
Services)
4-Hour On-site Service, 7-Day x 24-Hour Coverage, 3 Years, Electronic
6-Hour Call to Repair, On-site Service, 7-Day x 24-Hour Coverage, 3 Years,
Electronic
Installation & Start-up Services
Hardware Installation, Electronic
Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the
Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am5pm, M-F, excl. HP holidays, Electronic
Support Plus
Onsite HW support, 8am-9pm, M-F, 4hr response and Microsoft O/S SW Tech
support offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP
holidays, Electronic
Onsite HW support, 8am-9pm, M-F, 4hr response and Linux O/S SW Tech support
offsite, onsite at HP's discretion, 8am-9pm, M-F 2hr response time excl. HP holidays,
Electronic
Support Plus 24
Onsite HW support 24x7, 4hr response and Microsoft O/S SW Tech support offsite,
onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
Onsite HW support 24x7, 4hr response and Linux O/S SW Tech support offsite, onsite
at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic
AF101A
AF102A
AF103A
AF110A
293052-B21
U4697E
U4698E
U4699E
U4707E
U4708E
U4709E
U4711E
U4710E
U4712E
NOTE: For more information, customer/resellers can contact
http://www.hp.com/services/carepack
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 26
QuickSpecs
HP ProLiant DL560
Memory
HP ProLiant DL560
Standard Memory
1024 MB PC2100 Registered DDR SDRAM DIMM Memory comes installed (2 x 512 MB SDRAM)
Standard Memory Plus Optional Memory
Up to 9216 MB memory is available with the optional installation of PC2100 Registered DDR SDRAM DIMM Memory Option Kit
Standard Memory Replaced with Optional Memory
Up to 12,288 MB of memory is available with the removal of the standard 1024 MB of memory, the optional installation of PC2100
Registered DDR SDRAM DIMM Memory Option Kit
NOTE: This chart does not represent all possible memory configurations.
Memory
Standard 1024 MB
Optional 9,216 MB
Maximum 12,288 MB
1
512 MB
512 MB
2048 MB
2
512 MB
512 MB
2048 MB
Standard Memory Board (Slots)
3
4
Empty
Empty
2048 MB
2048 MB
2048 MB
2048 MB
The following memory options are available from HP:
512 MB of PC2100 ECC DDR DIMM Memory Kit (2 x 256 MB)
1 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 512 MB)
2 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 1 GB)
4 GB of PC2100 DDR SDRAM DIMM Memory Kit (2 x 2 GB)
DA - 11595
Worldwide — Version 43 — November 7, 2005
5
Empty
2048 MB
2048 MB
6
Empty
2048 MB
2048 MB
300678-B21
300679-B21
300680-B21
300682-B21
Page 27
QuickSpecs
HP ProLiant DL560
Storage
A
1.44-MB Diskette Drive
B
Ejectable: 24x IDE CD-ROM (Slimline)
0-1
Wide Ultra3/Ultra320 Drive Cage
Drive Support
Quantity
Supported
Slim Line Drives
1.44-MB slim-line Diskette Up to 1
Drive
Ejectable IDE slim-line
Up to 1
CD-ROM Drive
Slimline DVD-ROM Drive Up to 1
(8X/24X) Option Kit
(ejectable)
Position
Supported
Controller
A
Integrated
B
Integrated IDE
B
Integrated IDE
Hard Drives
Ultra320 Hot Pluggable Drives
Position
Quantity
Supported
Supported
Controller
1-inch
300-GB 10,000 rpm
Up to 2
0-1
Integrated Dual Channel Wide Ultra3 SCSI Adapter
146.8-GB 10,000 rpm
Smart Array 6402/128Controller
72.8-GB 10,000 rpm
Smart Array 641 Controller
146.8-GB 15,000 rpm
Smart Array 642 Controller
72.8-GB 15,000 rpm
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
36.4-GB 15,000 rpm
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320
Smart Array Controller or U320 SCSI HBA to support U320 transfer rates.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 28
QuickSpecs
HP ProLiant DL560
Storage
External Storage
Modular Smart Array 20
Modular Smart Array 30
Family
Quantity
Supported
1 per SCSI
VHDCI
connector
Up to 13
Position
Supported
External
External
Host Controller or Adapter
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
Please see the Modular Smart Array 500 QuickSpecs for the latest
list of supported HBAs: http://www.hp.com/go/msa500
Please see the Modular Smart Array 1000 QuickSpecs (URL below)
for the latest list of supported HBAs
Modular Smart Array 500 1
External
G2 System
Modular Smart Array
Please see the
External
1000
Modular Smart
Array 1000
QuickSpecs
below to
determine
configuration
requirements
Modular Smart Array
Please see the
External
Please see the Modular Smart Array 1500 cs QuickSpecs (URL
1500 cs
Modular Smart
below) for the latest list of supported HBAs
Array 1500 cs
QuickSpecs
below to
determine
configuration
requirements
Modular Smart Array 1000:
http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML (Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML (North America)
Modular Smart Array 1500: http://www.hp.com/go/MSA1500cs
Maximum Storage Capacity – (External Enclosure Attached)
Internal
600 GB (2 x 300 GB Ultra320 SCSI 1" Drives)
External
50.40 TB (12 x (14 x 300 GB Ultra320 SCSI 1" Drives))
Total
51.00 TB
Tape Drives, Tape Autoloaders, & Tape Libraries
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 29
QuickSpecs
HP ProLiant DL560
Storage
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/North_America/10233.html (North America)
http://h18000.www1.hp.com/products/quickspecs/Division/10233.html (Worldwide)
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Autoloaders & Tape Libraries listed below,
please see the following:
http://h18000.www1.hp.com/products/quickspecs/North_America/10809.html (North America)
http://h18000.www1.hp.com/products/quickspecs/Division/10809.html (Worldwide)
NOTE: For complete listing of tape drive offerings see
http://www.hp.com/products1/storage/compatibility/tapebackup/ISS/index.html
For details on connecting tape drives to this server, see the following:
Quantity
Supported
1
Position
Supported
0, 1
HP StorageWorks Tape
Drives, USB External
DAT 24 USB
DAT 40 USB
DAT 72 USB
1 per USB port
External
USB port
HP StorageWorks Tape
Drives, External
Ultrium 215
Ultrium 230
Ultrium 232
Ultrium 448
Ultrium 460
DAT 40
DAT 72
DLT VS80
DLT VS160
SDLT 320
Up to 2
External
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
HP StorageWorks Tape
Drives, External
Ultrium 960
SDLT 600
1 drive per SCSI External
channel
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
HP StorageWorks DAT
Tape Drives, Internal Hot
Plug
DAT 40 Tape Drive
DAT 72 Tape Drive
DA - 11595
Controller
Smart Array 5i Plus Controller (integrated on system board)
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
Worldwide — Version 43 — November 7, 2005
Page 30
QuickSpecs
HP ProLiant DL560
Storage
HP StorageWorks
Autoloaders, External
DAT 72x6 Tape
Autoloader
1/8 Tape Autoloader
SSL1016 Tape
Autoloader
1 autoloader per External
SCSI channel
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
HP StorageWorks Rackmount Tape Drive
Enclosures
1U Rack-Mount Kit
3U Rack-Mount Kit
5U Rack-Mount Kit
1 per SCSI
channel
64-Bit/133MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/133-MHz Single Channel Ultra320 SCSI HBA G2
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate
OS
HP StorageWorks Tape
Libraries, External
MSL6000 (Ultrium 960based)
MSL6000 (SDLT 600based)
MSL6000 (Ultrium 460based)
MSL5026S2 (SDLT 320based)
MSL5052S2 (SDLT 320based)
Please reference External
the MSL Tape
Library
QuickSpecs to
determine
configuration
requirements
DA - 11595
External
Please consult the EBS connectivity matrix at
http://www.hp.com/go/ebs for detailed connectivity information.
Worldwide — Version 43 — November 7, 2005
Page 31
QuickSpecs
HP ProLiant DL560
Power Specifications
Part Number
Spare Kit
Operational Input Voltage
Range (V rms)
Frequency Range (Nominal)
(Hz)
280126-001
280126-B21
90 to 264
47 to 63 (50/60)
Nominal Input Voltage (Vrms)
Max Rated Output Wattage Rating
Nominal Input Current (A rms)
Max Rated Input Wattage Rating (Watts)
Max. Rated VA (Volt-Amp)
Efficiency (%)
Power Factor
Leakage Current (mA)
Maximum Inrush Current (A peak)
Maximum Inrush Current duration
100
550
7.1
696
710
79
0.98
.87
100
20
115
550
6.1
688
702
80
0.98
1.00
100
20
208
550
3.3
679
693
81
0.98
1.81
100
20
220
550
3.1
671
684
82
0.98
1.91
100
20
230
550
3.0
667
680
82.5
0.98
2.00
100
20
240
550
2.8
663
676
83
0.98
2.09
100
20
System Specifications
HP ProLiant DL560 Fully Configured
Up to 4 Processors, 6 Memory Slots, 2 Hard Drives, 3 PCI Slots, and 2 Hot Plug Power Supplies
Nominal Input Voltage (Vrms)
Fully Loaded System Input Wattage (W)
Fully Loaded System Input Current (A rms)
Fully Loaded System Thermal (BTU- Hr)
Fully Loaded System VA (Volt-Amp)
System Leakage with all power supplies loaded
(mA)
System Inrush Current with all power supplies
loaded (A)
Power cord requirements
100
534
5.4
1820
545
.87
115
527
4.7
1707
538
1.00
208
520
2.6
1774
531
1.81
220
514
2.4
1752
524
1.91
230
507
2.3
1730
518
2.00
240
501
2.1
1709
511
2.09
200
200
200
200
200
200
Nema 5-15P to IEC320-C13
IEC320-C13 to IEC320-C14
Option no./Spare no: 163719-002
Option no./Spare no: 142259-001/
142258-B21
NOTES:
NOTES
ActiveAnswers Power Calculation
Power calculator is LIVE on ActiveAnswers Web site. This is an external link.
Follow this link: http://h30099.www3.hp.com/configurator/powercalcs.asp.
To drill down to calculators:
- Click on: "ProLiant Servers"
Click on the Server of interest. Example: DL560
Click on: "Power Calculator" link (You may need to scroll down to see it.)
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 32
QuickSpecs
HP ProLiant DL560
Technical Specifications
System Unit Rack
Chassis Footprint
(HxWxD)
Weight
3.38 x 17.50 x 25.75 in (8.59 x 44.45 x 65.41 cm)
Maximum (2 Power
60 lb (27 kg)
Supplies, 2 Hard Drives)
Minimum (No hard drives 35 lb (16 kg)
installed, one power
supply)
Input Requirements
Rated Input Voltage
100 to 120 VAC/200 to 240 VAC
Rated Input Frequency
50 to 60 Hz
Input Power
690W @ 115 VAC/675W @ 230 VAC
Rated Input Current
7A (100 VAC), 6A (115 VAC), 3A (230 VAC)
Max BTU Rating
2375 BTU (550 Watts)
Power Supply Output
Rated Steady-State Power 550W/550W (lowline/highline)
Power (per power supply) Maximum Peak Power
550W/550W (lowline/highline)
Temperature Range
Operating
50° to 95° F (10° to 35° C)
Non-operating
-20° to 140° F (-29° to 60° C)
Shipping
-22° to 122° F (-30° to 50° C)
Relative Humidity
Operating
10% to 70%
(non-condensing)
Non-operating
5% to 95%
Maximum Wet Bulb
101.7° F (38.7° C)
Temperature
Acoustic Noise
NOTE: Listed are the declared A-weighted sound power levels LWAd and
the declared average bystander position sound pressure levels LpAm when
operating in a 23° C ambient environment. Noise emissions were measured
in accordance with ECMA 74 and declared in accordance with ECMA 109.
Idle (Fixed Disk Drives
Spinning)
L WAd (BELS)
6.0
L pAm (dBA)
46
NOTE: These values apply to 2U rack configuration. Configuration tested
included 2 processors, two 10, 000 rpm hard drive, 1 power supplies, 1
power supply fan and 4 CPU fans.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 33
QuickSpecs
HP ProLiant DL560
Technical Specifications
24X Max (or higher) IDE
CD-ROM Drive Slimline
Disk
Applicable Disk
Capacity
Block Size
Interface
Access Times (typical)
Data Transfer Rate
Cache Buffer
Start-up Time (typical)
Stop Time
Laser Parameters
Operating Conditions
Dimensions
Slimline CD-RW/DVDROM 24X Combo Drive
(Multibay)
Shipping Dimensions
Shipping Weight
Disk
DA - 11595
Diameter
Rotational Speed
Center Hole
Thickness
Track Pitch
Mode 1
Mode 2
CD-DA
CD-XA
IDE (ATAPI)
Random
Full-Stroke
Sustained
Burst
128 KB
< 7seconds
< 4seconds
Type
Wave Length
Divergence Angle
Output Power
Temperature
Humidity
(HxWxD, maximum)
Weight
CD-DA, CD-ROM (Mode 1 and 2)
CD-XA, CD-I (Mode 2, Form 1 and 2)
Photo CD (Single and Multi-session)
Mixed Mode (Audio and Data combined)
540 MB (Mode 1, 12 cm)
650 MB (Mode 2, 12 cm)
4.7 x 3.15 in/12 x 8 cm
4200 rpm maximum
0.6 in/15 mm diameter
1.2 mm
1.6 µm
2,048
2,340, 2,336, 1,024 bytes
2,352 bytes
2,328 bytes
100 ms
2000 ms
150 KB/s (sustained 1X)
2100 to 3600 KB/s
Semiconductor Laser GaA1As
780 ± 25 nm
53.5° ± 1.5°
0.14 mW
41° to 113° F (5° to 45° C)
10% to 80%
1.69 x 5.75 x 8.19 in (4.29 x 15 x 20.8 cm)
2.66 lb (1.2 kg)
13.88 x 11.38 x 9.25 in (35.26 x 28.91 x 23.50 cm)
5 lb (2.27 kg)
DVD-ROM
Applicable Disk
DVD-R (Read Only)
2.6 GB/side DVD-RAM (Read Only)
5.2 GB/side DVD-RAM (Read Only)
CD-ROM Mode-1 data disc
CD-ROM Mode-2 data disc
CD Audio disc
CD-Extra
CD-RW
Worldwide — Version 43 — November 7, 2005
Page 34
QuickSpecs
HP ProLiant DL560
Technical Specifications
Capacity
CD-R
CD Text
PhotoCD
CD-I (mode 2)
CD-I Ready
CD-Bridge
DVD-ROM
DVD-SL
DVD-DL
Double
Sided
4.7 GB/side
8.5 GB/side
9.40 GB/side
DVD-R
DVD-RAM
Block Size
Diameter
Loading Mechanism
Interface
Access Times (typical)
Audio Output Level
(typical)
Data Transfer Rate
(sustained)
Cache Buffer
Spin-up Time (typical)
MTBF
Ambient Temperature
Relative Humidity
Dimensions
Option Kit Contents
DA - 11595
Tray type
EIDE (ATAPI)
Random
Full-Stroke
Line-out
3.95 GB/side
2.6 GB/side and
5.2 GB/
CD-ROM
Mode-1 650 MB (550 MB)
Mode-2 742 MB (640 MB)
DVD
2,048 bytes
CD
2,352 (Mode-0)
2352, 2340,
2336, 2048 bytes
(Mode-1)
2352, 2340,
2336, 2048 bytes
(Mode-2)
120 mm, 80 mm (with adapter at vertical
mounting mode)
DVD-ROM < 120 ms, CD-ROM < 110 ms
DVD-ROM < 240 ms, CD-ROM < 160 ms
CD 0.7 Vrms at 47 Kohms Load
DVD-ROM
Single Layer
10.8 MB/sec. Max.
DVD-RAM
2.77 MB/sec. Max
CD-ROM
7.2 MB/sec. Max.
2 MB
less than 10 seconds
120,000 Power On Hours
(POH)
Operating
-22° to 140° F (-30° to 60° C)
Operating
10% to 80%
Storage/Transportation
5% to 95%
(HxWxD, maximum)
0.5 x 5.04 x 5.1 in (12.7x128x129.4 mm)
DVD-ROM drive with installation guide, warranty card, registration card
Worldwide — Version 43 — November 7, 2005
Page 35
QuickSpecs
HP ProLiant DL560
Technical Specifications
Integrated Lights-Out
Standard (integrated on
system board)
Architecture
Processor
Upgradability
Video Support
Interfaces
Memory
Operating System
Support
Client Browser Support
iLO Standard Features
iLO Advanced Features
(optional)
32-bit PCI-based health and remote management ASIC (Application Specific
Integrated Circuit)
32-bit RISC processor core running at 66 MHz
Option firmware upgradable via flash ROM.
Utilizes the host server's embedded video chip. Supports VGA/SVGA, 640 x
480 (256 to 16.7M colors), 800 x 600 (256 to 16.7M colors), 1024 x 768
(256 to 65K colors), 1280 x 1024 (256 colors)
One Ethernet network connection (10/100 Mb/s)
2-MB Flash ROM
8-MB SDRAM
United Linux 1.0
Windows 2000 Server
Windows 2000 Advanced Server
Red Hat 7.x
SLES8
Novell NetWare 5.x, 6.x
Microsoft Internet Explorer 5.5 or later.
Virtual Text Remote Console
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for up to 12 user accounts with customizable access privileges
Virtual Graphical Remote Console
Virtual Floppy Drive
Integrated Smart Array 5i Data Compatible with all Yes
Plus Controller
Smart Array Controllers
Instant Upgrades to other Yes
Smart Array Controllers
Yes
Consistent Software
Manageability Tools
64-bit, 100 MHz (integrated on system board)
PCI-X Bus
PCI-X Peak Data Transfer 800 MB/s
Rate
SCSI Protocols Supported Ultra3, Ultra2
SCSI Peak Data Transfer 160 MB/s per channel
Rate
2 (only one connected)
Channels
0/1
SCSI Ports
(external/internal)
2
Drives Supported
(maximum)
NOTE: Maximum is the total number of internal drives on each specific ProLiant server.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 36
QuickSpecs
HP ProLiant DL560
Technical Specifications
Cache
Battery-Backed Write
Cache
RAID Support
Logical Drives (maximum)
Online Configuration
Online Capacity
Expansion
Logical Drive Capacity
Extension
Online Stripe Size
Migration
64 MB Read and/or Write Cache
Yes, with installation of Battery-Backed Write Cache Enabler, up to 64MB
Online RAID Level
Migration
Online Spare Support
Automatic Data Recovery
Drive Roaming
Redundant Controllers
Yes
Two NC7781 PCI-X
Network Interface
Gigabit NICs (embedded) Compatibility
Server Adapter
Data Transfer Method
Network Transfer Rate
Connector
Cable Support
0, 1
Maximum = total number of drives
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
10/100/1000-T
IEEE 802.3 10Base-T
IEEE 802.3ab 1000Base-T
IEEE 802.3u 100Base-TX
64-bit/133MHz PCI-X
10Base-T (Half-Duplex)
10 Mb/s
10Base-T (Full-Duplex)
20 Mb/s
100Base-TX (Half-Duplex) 100 Mb/s
100Base-TX (Full-Duplex) 200 Mb/s
1000Base-T (Full and
2000 Mb/s
Half-Duplex)
RJ-45
10Base-T
Category 3,4 or 5 UTP up to 328 ft (100 m)
10/100/1000Base-T
Category 5 UTP (2 pair); up to 328 ft (100 m)
© Copyright 2005 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel
Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial
errors or omissions contained herein.
DA - 11595
Worldwide — Version 43 — November 7, 2005
Page 37