Industrial Ethernet Gateways
MGate™ 5111 Series
1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateways
››Supports PROFIBUS DP V0 slave
››Supports Modbus RTU/ASCII/TCP master or slave
››Supports EtherNet/IP adapter or PROFINET IO device
››Built-in traffic monitoring/diagnostics/status monitoring and fault
protection
››Built-in Ethernet cascading for easy wiring
››Redundant dual DC power inputs and relay output supported
››microSD card for configuration backup/duplication, and event log
››Serial port with 2 kV built-in isolation protection
››-40 to 75°C wide operating temperature models available
››Security features based on IEC-62443
Introduction
MGate 5111 industrial Ethernet gateways convert data between the
Modbus RTU/ASCII/TCP, EtherNet/IP, PROFINET, and PROFIBUS
protocols. All models are protected by a rugged metal housing, are
DIN-rail mountable, and offer built-in serial isolation.
Modbus is one of the most widely used industrial communication
protocols, and EtherNet/IP, PROFINET, and PROFIBUS are commonly
used in factory automation and process automation. The MGate 5111
supports both Modbus RTU/ASCII/TCP master and slave modes, so
that you can easily connect your Modbus device to PROFIBUS PLCs or
DCSs, such as Siemens PLCs.
For Sytem integration, the MGate 5111 can connect to EtherNet/
IP PLC/SCADA systems, such as Rockwell Automation PLCs, to
PROFIBUS PLC/DCS systems, or between a new Siemens PLC system
that supports PROFINET to an existing PROFIBUS system. The
MGate 5111 gateways are designed for easy configuration and quick
maintenance. A handy web console can be used to implement remote
maintenance tasks, and the configuration wizard UI lets you quickly set
up your gateway. A comprehensive collection of troubleshooting tools
reduce configuration time and system downtime. The rugged design
is suitable for industrial applications such as factory automation,
power, oil & gas, water and wastewater, and other process automation
industries.
Easy Configuration
The MGate 5111 series gateway has a friendly user interface that lets
you quickly set up protocol conversion routines for most applications,
doing away with what were often time-consuming tasks in which users
had to implement detailed parameter configurations one by one. With
Quick Setup, you can easily access protocol conversion modes and
finish the configuration in a few steps. The MGate 5111 supports a
web console and Telnet console for remote maintenance. Encryption
communication functions, including HTTPS and SSH, are supported
to provide better network security. In addition, system monitoring
functions are provided to record network connections and system log
events.
Variety of Maintenance Functions
The MGate 5111 supports Protocol Diagnose and Traffic Monitor
for easy troubleshooting, especially during the installation stage.
Communication issues caused by incorrect software parameters,
like slave IDs and register addresses, or incorrect command
configurations, can be fished out with Protocol Diagnose and Traffic
Monitor, which let you capture and check data to easily identify root
causes.
1
MGate 5111 gateways also support status monitoring and fault
protection functions. The status monitoring function notifies a PLC/
DCS/SCADA system when a Modbus device gets disconnected or
does not respond, in which case the process PLC/DCS gets the status
of each end device and then issues alarms to notify operators. When
a PROFIBUS cable gets disconnected, the fault protection function
executes actions on end devices identified by a pre-defined value set
by the user.
w w w. m o x a . c o m
Industrial Ethernet Gateways
Specifications
Industrial Protocols
Protocols: PROFIBUS, Modbus RTU/ASCII/TCP, PROFINET, EtherNet/IP
Protocol Conversion:
• Modbus RTU/ASCII (Master/Slave) to PROFIBUS slave
• Modbus TCP (Client/Server) to PROFIBUS slave
• EtherNet/IP (Adapter) to PROFIBUS slave
• PROFINET (IO Device) to PROFIBUS slave
Ethernet Interface
Protocols: Modbus TCP (Client/Server), PROFINET (IO device),
EtherNet/IP (Adapter)
Number of Ports: 2 (1 IP address, supports Ethernet cascading)
Speed: 10/100 Mbps, Auto MDI/MDIX
Connector: 8-pin RJ45
Magnetic Isolation Protection: 1.5 kV (built-in)
PROFIBUS Interface
Protocol: PROFINET RT IO Device
Max. Total I/O Data Size:
Input: 512 bytes
Output: 512 bytes
Maximum No. of Connections: 1 master connection
Software
Configuration Options: Web console, Serial console
Utility: Device Search Utility (DSU) for Windows 95, 98, ME, NT, 2000,
Windows XP, Server 2003, Vista, Server 2008 (x86/x64), Windows
Server 2008 R2, Windows 7/8/8.1/10 (x86/x64), Windows Server 2012
(x64), Windows 2012 R2
Network Protocols: TCP/IP, UDP, HTTP, HTTPS, SMTP, NTP, DNS,
DHCP Client, SNMP (v1, v2c, v3), MIB-II, ARP, Telnet, SSH
Support: MXview, MXconfig
Protocol: PROFIBUS DP-V0 Slave
Number of Ports: 1
Data Rate: 9600 bps to 12 Mbps
Connector: DB9 female
Isolation: 2 kV (built-in)
Rotary Switch: PROFIBUS address 0-99 (address 100-125 supported
through software configuration)
Physical Characteristics
Modbus Serial Interface
Environmental Limits
Protocols: Modbus RTU/ASCII (Master/Slave)
Number of Ports: 1
Serial Standards: RS-232/422/485, software selectable
Connectors: DB9 male
Pull High/Low Resistor for RS-485: 1 kΩ, 150 kΩ
Terminator for RS-485: 120 Ω
Isolation: 2 kV (built-in)
Modbus Serial Communication Parameters
Housing: Metal, IP30
Weight: 589 g (1.30 lb)
Dimensions: 45.8 x 105 x 134 mm (1.8 x 4.13 x 5.28 in)
Storage Card Slot: 1 microSD (SDHC) card slot; supports up to 32 GB
Relay Alarm Circuit: 3-pin circuit with current carrying capacity of 2 A
@ 30 VDC
Operating Temperature:
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Vibration: IEC 60068-2-6, IEC 60068-2-64
Shock: IEC 60068-2-27
Drop: IEC 60068-2-32
Data Bits: 8
Stop Bits: 1, 2
Parity: None, Even, Odd, Space, Mark
Flow Control: RTS/CTS, RTS Toggle (RS-232 only)
Baudrate: 50 bps to 921.6 kbps
Power Requirements
Modbus Serial Signals
Safety: EN 60950-1(LVD), UL 61010-2-201
Hazardous Location: Class I Division 2, ATEX, IECEx
EMC: EN 61000-6-2/6-4
EMI: CISPR 22, FCC Part 15B Class A
EMS:
IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: Power 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 150 kHz to 80 MHz: 10 V/m
IEC 61000-4-8 PFMF: 30 A/m
RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422: Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w: Data+, Data-, GND
Modbus TCP Interface
Protocols: Modbus TCP client/server
Functions Supported: 1, 2, 3, 4, 5, 6, 15, 16, 23
Max. Number of Commands: 128
Max. Number of Connections:
• MGate as Modbus TCP Client: 32 connections
• MGate as Modbus TCP Server: 16 connections
Max. Total I/O Data Size:
Input: 2048 bytes
Output: 2048 bytes
EtherNet/IP Interface
Class: Adapter
CIP Objects Supported:
Identity, Message Router, Assembly, Connection Manager, TCP/IP
interface, Ethernet link, Port
Max. Number of Connections:
• MGate as Adapter:
1 connection for read/write
1 connection for read-only
Max. Total I/O Data Size:
Input: 496 bytes
Output: 496 bytes
2
PROFINET Interface
Input Voltage: 12 to 48 VDC
Input Current: 416 mA max.
Power Connector: Terminal block
Standards and Certifications
Reliability
Alarm Functions: Relay, email, SNMP trap
Alert Tools: Built-in buzzer
MTBF (mean time between failures)
Time: 718,131 hrs
Standard: Telcordia SR332
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
w w w. m o x a . c o m
Industrial Ethernet Gateways
Dimensions
Unit: mm (inch)
10M
100M
100M
100M
100M
MODBUS
PROFIBUS
MODBUS
PROFIBUS
99.70 (3.925)
PBS
10M
10M
10M
MB
134.00 (5.276)
LAN
PBS
5111
5111
4.50 (0.177)
8.80 (0.346)
Ø7.00 (0.276)
41.00
(1.614)
16.50 (0.650)
51.60 (2.032)
Ø3.50 (0.138)
13.60 (0.535)
PWR1 PWR2 Ready
LAN
MB
28.00 (1.102)
18.75 (0.738)
PWR1 PWR2 Ready
33.60 (1.323)
45.80 (1.803)
16.51 (0.650)
105.00 (4.134)
7.65 (0.301)
22.90 (0.902)
38.15 (1.502)
Ordering Information
Available Models
MGate 5111: Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateway, 0 to 60°C operating temperature
MGate 5111-T: Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateway, -40 to 75°C operating
temperature
Optional Accessories (can be purchased separately)
Package Checklist
• 1 MGate 5111 gateway
• Quick installation guide (printed)
• Warranty card
WK-51-01: Wall-mounting kit, 2 plates with 6 screws
Mini DB9F-to-TB: DB9 female to terminal block connector
3
© Moxa Inc. All rights reserved. Updated Dec. 29, 2017. Specifications subject to change without notice. Please visit our website for the most up-to-date product information.