Vaisala Mid-Range Data Loggers for Temperature, Humidity

Vaisala Mid-Range Data Loggers for Temperature,
Humidity & Contact Channel Measurement
Designed for Controlled
Environments such as:
▪
▪
▪
▪
▪
▪
▪
▪
▪
Vaisala’s Mid-Range data loggers are
designed for early phase drug and
device development applications
where speed and economy are
critical. The MR loggers can be used
with Vaisala software to monitor
and analyze environmental data and
provide presentation-quality records
that are easily exported to PDF and
spreadsheets.
Simplified Calibration
Easy to install and configure, the
MR loggers are calibrated with an
abbreviated process that provides
reliable accuracy in operating
environments between -55 °C
to +50 °C.
The MR loggers include NISTtraceable calibration in one of
Vaisala’s accredited calibration
laboratories to ensure cGMP, ISO
9000 and HACCP quality standards.
Optional services are available,
including extended warranties and
onsite calibration.
Easy Configuration
Connectivity options include USB,
wireless, and Power over Ethernet
with a vNet PoE network interface.
When MR loggers are used with
vNet PoE device, installation takes
minutes. With the vNet device,
loggers are automatically identified
on your network by the software.
Lean Validation
For applications that require
validation, we offer efficient and
practical protocols that allow for
quick verification of data logger
functions. See Express IQOQ and
Rapid IQOQ under “Accessories”
on page 3.
Software Options
Whether you need multistage
alarming sent via text, email, PC
display or dial-out, or to perform
a comprehensive mapping study,
Vaisala has user-friendly software
designed for use in regulated
environments, including:
Drug Discovery, R&D
Early Phase Clinical Trials
Blood & Tissue Banks
Hospitals & Pharmacies
Nutraceutical Manufacturing
Food & Dietary Supplement
Applications
Aerospace
Semiconductors
Museums & Archives
• viewLinc Continuous Monitoring
and Alarming
• vLogSP for Validation/Mapping
applications
Data Logger Options
Six versions of the MR Loggers are
available with up to four channels
of Temperature-Only, Temperature
+ Humidity, or Boolean contact
channel for door switches/alarm
contact recording:
• DL1000MR - 1 internal
temperature channel
• DL1016MR - 2 channel
temperature with probes
• DL1016MRB - 2 channel with
1 temperature probe, and
1 contact input
• DL1416MR - 4 channel
temperature with probes
• DL1416MRB - 2 channel
temperature with probes, and
2 contact inputs
• DL2000MR - 2 internal channels
Temperature and RH
Technical Data
General
Temperature Sensors
Size
Internal Sensor type
85 x 59 x 26 mm (3.4 x 2.3 x 1")
76 g (2.7 oz.)
Interfaces
RS-232 serial
Ethernet
USBWiFi
vNet PoE network interface
Mounting
Magnetic strips
3M Dual Lock™ Fasteners
Snap-in connector for secure probe
connections
Software
• vLog Validation/Mapping
• viewLinc Continuous Monitoring &
Alarming
• OPC Server to add Vaisala loggers to
any OPC compatible monitoring system
Internal clock accuracy ±1 min. /month
0 °C to +50 °C (32 °F to +122 °F)
Electromagnetic
FCC Part 15 and CE
compatibility
Power source
Internal 10-year lithium battery1
1
Battery life specified with sample interval of 1 min. or longer
Memory
Data Sample Capacity
DL1000MR
DL1016MR/MRB
DL1416MR/MRB
DL2000MR
Memory type
Memory Mode
Sampling Rates
48,100 12-bit samples
68,600 16 bit samples
101,375 16 bit samples
122,197 12-bit samples
Non-volatile EEPROM
User-selectable wrap (FIFO) or stop when
memory is full
User-selectable rates from once every
10 seconds to once per day
(Battery life specified with sample interval
of 1 min. or longer)
Precision-tolerance epoxy
encapsulated NTC thermistor
EXTERNAL TEMPERATURE PROBES
Sensor Tip
Diameter
Length
Stainless Steel
3.2 mm (1/8")
38 mm (1.5")
PROBE CABLE LENGTHS
DL1016MR/MRB
DL1416MR/MRB
CABLE CONSTRUCTION
2 mm (0.07") Diameter, Teflon coated cable
3 m (10')
7.6 m (25')
DL1000MR Internal Temperature Sensor
DL2000MR Internal Temperature/ RH Sensor
RANGE AND ACCURACY
TEMPERATURE RANGE AND ACCURACY
Logger Operating Range
Calibrated Measurement Range
Accuracy over temperature range2
at -25 °C ... +70 °C
(-13 °F .... +122 °F)
Resolution
-35 °C to +85 °C
(-31 °F to +185 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
RANGE AND ACCURACY
Probe Operating Range
Calibrated Measurement Range
0 °C to +50 °C
(32 °F to +122 °F)
-95 °C to +70 °C
(-139 °F to +158 °F)
-55 °C to +50 °C
(-130 °F to +122 °F)
Accuracy over temperature range3
at -55 °C ... +50 °C
(-67 °F .... +122 °F)
Resolution
±0.5 °C
(±0.9 °F)
0.01 °C at +25 °C
(0.02 °F at +77 °F)
2
Initial accuracy includes all known influence quantities present
at the time of calibration including calibration uncertainty,
mathematical fit, data logger resolution, hysteresis and
reproducibility.
Not included is any drift related to atypical contamination or
misuse.
Specification for external channels is for a probe calibrated to the
specified channel of the data logger, with the logger
at 0 °C to +50 °C (32 °F to +122 °F)
3
Calibrated Measurement Range
Accuracy over temperature range2
±0.5 °C
(±0.9 °F)
0.02 °C at +25 °C
(0.04 °F at +77 °F)
DL1016/1416MR External Temperature Sensors
Logger Operating Range
Operating Range
Resolution
-35 °C to +85 °C
(-31 °F to +185 °F)
-25 °C to +70 °C
(-13 °F to +158 °F)
at -25 °C ... +70 °C ±0.5 °C
(-13 °F .... +122 °F) (±0.9 °F)
0.02 °C at +25 °C
(0.04 °F at +77 °F)
RELATIVE HUMIDITY RANGE AND ACCURACY
Calibrated Measurement Points
45 %RH at +10 °C (+50 °F)
10 %RH and 80 %RH at +25 °C (+77 °F)
45 %RH at +25 °C (+77 °F)
45 %RH at +45 °C (+113 °F)
Operating Range
0 %RH to 100 %RH (non-condensing)
Temperature range
+20 °C ... +30 °C
10 ... 90 %RH ±2.0 %RH
(68 °F ... 86 °F)
Temperature range
-20 ... +20 °C, +30 ... +70 °C
10 ... 90 %RH ±3.0 %RH
(-4 °F ... 68 °F, 86 °F ... 158 °F)
Resolution
0.05 %RH
Humidity sensor
Vaisala HUMICAP® 180R
Stability
±2 %RH over 2 years
Accessories
TEMPERATURE PROBE
EPT-TDB: Thermal Dampening Block, for use in refrigerators and
freezers. The block simulates a glycol bottle to reduce alarms
generated by opening and closing doors.
BOOLEAN CONTACT CABLES
EPT-DS-25 Available cable with magnetic contact switch –
7.6 m (25') for use with MRB loggers.
VALIDATION DOCUMENTS
VL-VPE-VLNC-43 Express Validation
VL-VPR-VLNC-43 Rapid Validation
IQ is eight tests, OQ is
eleven tests. Testing includes
security testing for users.
IQ is eight tests, OQ is six
tests. Only tests that challenge
the basic operation of GxP
processes (i.e.: alarming and
data collection).
Ref. B211412EN-A ©Vaisala 2014
This material is subject to copyright protection, with all
copyrights retained by Vaisala and its individual partners. All
rights reserved. Any logos and/or product names are trademarks
of Vaisala or its individual partners. The reproduction, transfer,
distribution or storage of information contained in this brochure
in any form without the prior written consent of Vaisala is strictly
prohibited. All specifications — technical included — are subject
to change without notice.