Model MI05-104 Merge/Isolate Cabinet

Pub. MI05-104iom.6
GAI-TRONICS
®
CORPORATION
A HUBBELL COMPANY
Model MI05-104 Merge/Isolate Cabinet
Confidentiality Notice
This manual is provided solely as an installation, operation, and maintenance guide, which contains
sensitive business and technical information, that is confidential and proprietary to GAI-Tronics.
GAI-Tronics retains all intellectual property and other rights in or to the information contained herein,
and such information may only be used in connection with the operation of your GAI-Tronics product or
system. This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any
third party.
General Information
The Model MI05-104 Merge/Isolate Cabinet is designed to operate in a multi-zone Page/Party®
communication system. The cabinet can selectively merge and isolate up to five zones that normally
operate independently. Each zone’s Page/Party® communication cable, which contains five party lines
and one page line, is connected to the merge/isolate cabinet.
When merged, the zones share a page line and a party line. For example, two zones can be merged while
the remaining zones in the system are isolated and continue to operate independently. Voice pages
generated from handset stations within one zone can be heard in the other zone when the two zones are
merged. The actual merging and isolating of the zones is controlled by a GAI-Tronics Model MS05-101
Master Desktop Station (or equivalent), which works in conjunction with the cabinet. The cabinet
supports a maximum of eight master stations.
In addition to merging and isolating the system zones, the cabinet can also perform other functions when
equipped with the following accessories, all of which can be added at any time:

MS05-101 Master Desktop Station or equivalent—A Page/Party® handset station that also provides
the capability for an operator to direct the merging and isolating of zones and manual initiation of
alarms when used in conjunction with the merge/isolate cabinet.

10959-201 Audio Messenger Interface (AMI)—A microprocessor-controlled tone/speech generator
that produces alarm tones (with speech messages) to alert people of emergency conditions.

10959-203 Audio Messenger Interface with Telephone Interface—Provides the same features and
functions as the Model 10959-201 described above, but adds telephone interface circuits to allow
telephone users the ability to make voice pages and to communicate with handset stations in the
Page/Party® system on party line 5.

GTK99019 Audio Interface—Allows other audio sources, such as 2-way radio equipment, to be
connected to the system.

Alarm Activation Switches—Allows external switch or relay contacts to activate the AMI. (The AMI
must be connected).

GTD99001-VLCX Volume Level Control Transmitter—Provides activation of remote devices using
existing system cable. This kit can be used to activate strobe lights via other devices or mute and
un-mute speakers at Page/Party® stations.
GAI-Tronics Corporation 400 E. Wyomissing Ave. Mohnton, PA USA
610-777-1374  800-492-1212  Fax: 610-796-5954
VISIT WWW.GAI-TRONICS.COM FOR PRODUCT LITERATURE AND MANUALS
Model MI05-104 Merge/Isolate Cabinet
Figure 1. Typical Block Diagram
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 2 of 22
Model MI05-104 Merge/Isolate Cabinet
Figure 2. Merge/Isolate Cabinet Component Locations
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 3 of 22
Pub. MI05-104iom.6
Page 4 of 22
Model MI05-104 Merge/Isolate Cabinet
Installation
NOTE: All system line balancing is located in this cabinet; therefore, any existing page and party line
balance assemblies must be removed when the Model MI05-104 Merge/Isolate Cabinet is installed.
Cabinet Mounting
Mount the merge/isolate cabinet in a secure area that is protected from adverse environmental conditions
such as rain, heavy dust, excess moisture, and temperature extremes. For optimum performance, mount
the cabinet no farther than one mile from the farthest Page/Party® station. Mount the enclosure to the wall
by installing four mounting bolts through the predrilled holes in the rear of the enclosure.
Field Wiring
All terminations are made to the termination PCBA using modular terminal block connections. Each
connection is labeled inside the merge/isolate cabinet.
Connecting Field Stations
1. Locate the termination PCBA in the lower left corner of the cabinet. See Figure 2.
2. Connect all page and party lines from each of the zones to the appropriate terminals on the
termination PCBA. No. 60038 Single-Party Cable or No. 60029 Multi-Party Cable is recommended.
TB1
Zone 1 field stations
TB2
Zone 2 field stations
TB3
Zone 3 field stations
TB4
Zone 4 field stations
TB5
Zone 5 field stations
3. Make the following connections:
Table 1. Field Station Connections
Terminals
Field Stations
Merge/Isolate Cabinet
Function
TB1-8 and TB1-9
TBx-1 and TBx-2
Page
TB2-12 and TB2-13
TBx-3 and TBx-4
Party Line 1
TB2-14 and TB2-15
TBx-5 and TBx-6
Party Line 2
TB2-16 and TB2-17
TBx-7 and TBx-8
Party Line 3
TB2-18 and TB2-19
TBx-9 and TBx-10
Party Line 4
TB2-20 and TB2-21
TBx-11 and TBx-12
Party Line 5
Refer to the manual for the custom
TBx-13 and TBx-14
station for terminal block numbers.
x = Applicable zone
Merge control
NOTE: For systems not employing any stations equipped with all-call or merge functions, connect the
spare orange conductor from the system cable to the C2 terminal at the respective zone terminal block.
Be sure to use GAI-Tronics system cable to connect all field stations to this cabinet, and terminate the
spare ac power conductors to the designated zone terminal block at the bottom of the cabinet. The ac
power conductors are color-coded black (L), white (N), and green/yellow (GND).
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 5 of 22
Model MI05-104 Merge/Isolate Cabinet
NOTE: These terminals do not provide ac power to the field stations and are provided only for the
convenience in terminating the system cable power conductors.
Connecting MS05-101 Desktop Master Stations (or equivalent)
1. Locate the termination PCBA in the lower left corner of the cabinet. See Figure 2.
2. Connect the desktop master station to TB6 in the cabinet.
Recommended cable for this connection is a nine-pair cable.
3. Make the following connections:
Table 2. Desktop Master Station Connections
Terminals
Master Station
Merge/Isolate Cabinet
Function
TB3-23 and TB3-24
TB6-1 and TB6-2
RS-485 Data Line (+/−)
TB3-25
TB6-3
Data ground
TB1-10 and TB1-11
TB6-5 and TB6-6
Page monitor
TB1-8 and TB1-9
TB6-7 and TB6-8
Page
TB2-12 and TB2-13
TB6-9 and TB6-10
Party Line 1
TB2-14 and TB2-15
TB6-11 and TB6-12
Party Line 2
TB2-16 and TB2-17
TB6-13 and TB6-14
Party Line 3
TB2-18 and TB2-19
TB6-15 and TB6-16
Party Line 4
TB2-20 and TB2-21
TB6-17 and TB6-18
Party Line 5
Master I/O Controller Switch Settings
The master I/O controller contains two hex switches labeled ADDRESS ID on the cover (See Figure 3).
These switches must be set to identify to the number of master stations in the system. This setting is
critical to ensure the master I/O controller recognizes the commands from all the master stations. Up to
eight master stations can be parallel-connected to the M/I cabinet.
Switches S1 and S2 are used to set the number of master stations in the system. The switch setting is
read as a hexadecimal number. Switch S1 is the LO address and switch S2 is HI address.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 6 of 22
Model MI05-104 Merge/Isolate Cabinet
Table 3. Switch Setting Examples
Switch
S2
Switch
S1
Number of
Master Stations
0
1
1
0
2
2
0
3
3
0
4
4
0
5
5
0
6
6
0
7
7
0
8
8
NOTE: The switch setting is recognized only when either the master I/O controller is powered up, or
when the RESET button is pressed. Momentarily press the RESET button each time a switch is changed.
The RESET button located next to the ADDRRESS ID Switches.
DIP Switch Settings
The master I/O controller switch S4 is an 8-position DIP switch that is used to set the data baud rate.
This switch is factory set and should not be changed. To access the DIP switch, the cover must be
removed from the I/O controller. If replacing the master I/O controller, be sure to set the switch as
follows:
Table 4. Dip Switch Settings
Switch Position
Open/Close
Switch Position
Open/Close
S4-1
Open
S4-5
Open
S4-2
Open
S4-6
Open
S4-3
Open
S4-7
Open
S4-4
Open
S4-8
Close
Press the reset switch following any switch changes.
Jumper Clip Settings
The Master I/O controller has two jumper clips, J6 and J7, which determine the data connection and
operating mode of the module, as follows:
J6—Is a three-position jumper that selects either RS-232 or RS-485 data communication. Always select
RS-485 by inserting the shorting clip across pins two and three on J6.
J7—Is a three-position jumper that puts the board in programming mode. Always select run mode by
inserting the shorting clip across pins one and two on J7.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 7 of 22
Figure 3. Master I/O Controller Module (Cover removed)
Fault Light Indicator
The red LED indicator on the audio switching PCBA illuminates if data communication is lost to any of
the master stations.
Alarm Mode Jumper
At the master I/O controller module, a jumper is pre-installed at the factory between terminals 15 and 16
at TB8. The following describes the modes of operation if the jumper is installed or removed:
Installed (manual alarm routing)—With the jumper installed, any alarm activation at the master or at
an external input will cause the AMI to become active, but the alarm audio will be broadcast only to the
master station(s). This feature allows the master station operator to direct the alarm audio to the zone(s)
affected by the alarm event.
Removed (automatic All-Zone alarm)—If the is jumper removed, any alarm activation at the master or
at an external input will cause the AMI to become active, and also automatically route the alarm audio to
all zones. The master operator can intervene and deselect zone(s) not affected by the alarm event.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 8 of 22
Model MI05-104 Merge/Isolate Cabinet
Setting Jumpers and Adjustments
Line Balance Adjustment for Page Lines
A line balance adjustment is provided for each zone and the master stations. The line balance adjustment
is factory-set for optimum performance but may need adjustment in some situations. If the line balance
adjustment is set too low, the speaker volume will also be low. If the line balance adjustment is set too
high, the speaker audio will be distorted. To correct low or distorted audio, complete the following
adjustments.
Master Stations
Perform the following steps to properly adjust the line balance assembly:
1. Remove the page line conductors from terminals 7 and 8 on the termination PCBA. See Figure 2 for
terminal block location for the master station.
2. Place an ohmmeter across terminals 7 and 8 on the termination PCBA.
NOTE: The optimum page line balance is 33 ohms.
3. Adjust potentiometer R15 on the audio switching PCBA to achieve 33 ohms on the ohmmeter.
Field Stations
Perform the following steps to properly adjust the line balance assembly for all zones:
1. Remove the zone page line conductors from terminals 1 and 2 on the termination PCBA. See Figure
2 for the terminal block location for each zone.
2. Place an ohmmeter across terminals 1 and 2 on the termination PCBA.
NOTE: The optimum page line balance is 33 ohms.
3. Adjust applicable potentiometer on the audio switching PCBA for each zone to achieve a reading of
33 ohms on the ohmmeter. Refer to the chart below for the correct potentiometer for each zone.
Table 5. Zone Potentiometers
Zone
Potentiometer
Zone 1
R2
Zone 2
R5
Zone 3
R8
Zone 4
R11
Zone 5
R17
Line Balance for Party Lines
The Model MI05-104 Merge/Isolate Cabinet provides line balancing for all system party lines. No user
adjustments are required for the party lines unless the party lines are made common and an external
device such as the Model 10959-203 Audio Messenger Interface with telephone interface circuits, or the
Model GTK99019 External Audio Interface, is used with the system. If party line four and/or five is used
for either the audio messenger interface or the external audio interface, the line balance must be removed
because each device provides the necessary line balancing for the designated party line.
To disable the internal line balance for either party line four and/or five, refer to the following table:
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 9 of 22
Model MI05-104 Merge/Isolate Cabinet
Table 6. Internal Line Balance Enable/Disable
Party
Line
Enable
Internal Line Balance
Jumpers
Disable
Internal Line Balance
4
JB51 and JB52
Jumper pins 1 and 2
Jumper pins 2 and 3
5
JB53 and JB54
Jumper pins 1 and 2
Jumper pins 2 and 3
Enable/Disable the Call-In Feature
Zone
Jumpers are provided on the termination PCBA to enable
or disable the call-in feature for each zone.

To enable the call-in feature, jumper pins two and
three on the termination PCBA.

To disable the call-in feature, jumper pins one and two
on the termination PCBA.
Call-In Feature Jumpers
1
JB1 and JB2
2
JB3 and JB4
3
JB5 and JB6
4
JB7 and JB8
5
JB9 and JB10
Configuring Common Party Lines between Zones
and Master Station
Jumpers are provided on the termination PCBA to make party lines two through five common across
zones and the master station(s). When a party line is made common between zones and the master
station, any station can pick up a handset and join the conversation.

To make a party line common, jumper pins one and two on the jumper assigned to the zone or master
station party line.

To isolate the party line, jumper pins two and three on the jumper assigned to the zone or master
station party line.
The following table lists the jumpers for each zone.
Table 7. Party Line Zone Configuration Jumpers
Zone
Party Line 2
Party Line 3
Party Line 4
Party Line 5
1
JB11 and JB12
JB13 and JB14
JB15 and JB16
JB17 and JB18
2
JB19 and JB20
JB21 and JB22
JB23 and JB24
JB25 and JB26
3
JB27 and JB28
JB29 and JB30
JB31 and JB32
JB33 and JB34
4
JB35 and JB36
JB37 and JB38
JB39 and JB40
JB41 and JB42
5
JB43 and JB44
JB45 and JB46
JB47 and JB48
JB49 and JB50
Master
N/A
N/A
JB51 and JB52
JB53 and JB54
Configuring Remote Switches to Activate Alarms
The cabinet can be configured to accept either normally open or normally closed switch contacts for
alarm activation. The cabinet provides connection for up to seven different alarm input circuits. Each
input circuit contains jumpers for the type of switch used: either normally open or normally closed.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 10 of 22
Model MI05-104 Merge/Isolate Cabinet
The following table outlines the jumper settings that are located on the external interface PCBA.
Table 8. Alarm Input Contact Configuration Jumpers
Input
Jumper
Normally Open
Normally Closed
1
J6


Jumper pins 1 and 2
Jumper pins 4 and 5


Jumper pins 3 and 4
Jumper pins 5 and 6
2
J7


Jumper pins 1 and 2
Jumper pins 4 and 5


Jumper pins 3 and 4
Jumper pins 5 and 6
3
J8


Jumper pins 1 and 2
Jumper pins 4 and 5


Jumper pins 3 and 4
Jumper pins 5 and 6
4
J9


Jumper pins 1 and 2
Jumper pins 4 and 5


Jumper pins 3 and 4
Jumper pins 5 and 6
5
J10


Jumper pins 1 and 2
Jumper pins 4 and 5


Jumper pins 3 and 4
Jumper pins 5 and 6
6
J11


Jumper pins 1 and 2
Jumper pins 4 and 5


Jumper pins 3 and 4
Jumper pins 5 and 6
7
J12


Jumper pins 1 and 2
Jumper pins 4 and 5


Jumper pins 3 and 4
Jumper pins 5 and 6
Cabinet Power Connections
Connect a 3-conductor, No. 14 AWG ac power cable (customer-supplied) to the line (L), neutral (N), and
ground (GND) terminals at the ac input terminal block located at the bottom right corner of the cabinet’s
termination panel. The ac source voltage to this cabinet can be either 120 V or 240 V, 50/60 Hz (see
note). Current draw is approximately 0.2 A at 120 V ac or 0.1 A at 240 V ac.
NOTE: The ac input voltage range for this cabinet is 90–264 V ac.
External Accessory Components
The following components are installed externally to the Model MI05-104 Merge/Isolate Cabinet. All
cable required for installation of this equipment must be provided by the installer.
Model 10959-201 Audio Messenger Interface
CAUTION
The AMI is supplied with an external plug-in power supply adapter, and it should
not be used in this application. Instead, connect the AMI’s input power terminals to the 24 V dc output
power terminals provided on the merge/isolate cabinet’s termination panel per the table below.
1. Mount the AMI in accordance with GAI-Tronics Pub. 42004-403, which is packaged with the
equipment.
2. Reprogram the AMI as described in the “Programming the AMI” section on Page 13. Several
parameters must be changed from the AMI’s factory default programming to allow proper operation
with the MI05 Series Merge/Isolate Cabinets.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 11 of 22
Model MI05-104 Merge/Isolate Cabinet
3. Connect the AMI to the external interface PCBA as follows using five pairs of No. 18–22 AWG
conductors for audio and alarm inputs, and a three-conductor cable for dc power. Refer to the
following table for all connections between the AMI and the M/I cabinet:
Table 9. AMI to External Interface PCBA Connections
Function
Page Line
Function
AMI Page/Party®
Interface PCBA
Connect
to
P1-3
P1-4
AMI
Termination
PCBA
Merge/Isolate External
Interface PCBA
TB3-8
TB3-7
Connect
to
Merge/Isolate External
Interface PCBA
Common
TB2-1
TB4-1
Alarm Input 1
TB2-2
TB4-8
Alarm Input 2
TB2-3
TB4-7
Alarm Input 3
TB2-4
TB4-6
Alarm Input 4
TB2-5
TB4-5
Alarm Input 5
TB2-6
TB4-4
Alarm Input 6
TB2-7
TB4-3
Alarm Input 7
TB2-8
TB4-2
Function
24 V dc
Ground
AMI
Termination
PCBA
Connect
to
Merge/Isolate
Termination Panel
TB6 +
AMI 24 V dc (+)
TB6 −
AMI 24 V dc (−)
TB6
AMI GND
Model 10959-203 Audio Messenger Interface with Telephone
Interface
CAUTION
The AMI is supplied with an external plug-in power supply adapter, and it
should not be used in this application. Instead, connect the AMI’s input power terminals to the 24 V dc
output power terminals provided on the merge/isolate cabinet’s termination panel per the table below.
1. Mount the AMI in accordance with Pub. 42004-403, which is packaged with the equipment.
2. Reprogram the AMI as described in the “Programming the AMI” section on Page 13. Several
parameters must be changed from the AMI’s factory default programming to allow proper operation
with the MI05 Series Merge/Isolate Cabinets.
3. Connect the AMI to the external interface PCBA as follows using eight pairs of No. 18–22 AWG
conductors for audio and alarm inputs, and a three-conductor cable for dc power cable. Refer to the
following table for all connections between the AMI and the M/I cabinet:
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 12 of 22
Model MI05-104 Merge/Isolate Cabinet
Table 10. AMI with Telephone Interface to External Interface PCBA Connections
Function
AMI Page/Party®
Interface PCBA
Connect
to
Merge/Isolate External
Interface PCBA
Page Line
P1-3
P1-4
TB3-8
TB3-7
Party Line 5
P1-1
P1-2
TB3-6
TB3-5
Function
AMI Termination
PCBA
Connect
to
Merge/Isolate External
Interface PCBA
Common
TB2-1
TB4-1
Alarm Input 1
TB2-2
TB4-8
Alarm Input 2
TB2-3
TB4-7
Alarm Input 3
TB2-4
TB4-6
Alarm Input 4
TB2-5
TB4-5
Alarm Input 5
TB2-6
TB4-4
Alarm Input 6
TB2-7
TB4-3
Alarm Input 7
TB2-8
TB4-2
Master Stn. Page
TB2-9
TB3-4
Common
TB2-10
TB3-3
Common
TB1-1
TB3-1
Aux. Output 1
TB1-2
TB3-2
Function
24 V dc
Ground
AMI Termination
PCBA
Connect
to
Merge/Isolate
Termination Panel
TB6 +
AMI 24 V dc (+)
TB6 −
AMI 24 V dc (−)
TB6
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
AMI GND
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 13 of 22
Figure 4. Audio Messenger Interface Connection Diagram
Programming the AMI
The Model 10959 Series AMI’s factory default programming must be changed prior to use with the MI05
Series Merge/Isolate cabinets. The programming is accomplished using the AMI Configuration Tool
(ACT) software provided with the AMI. Refer to the AMI manual and ACT help screens for details on
using the configuration software. Changes required for use with the MI05 Series Merge/Isolate Cabinets
are as follows:
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 14 of 22
Message Screen
A new message must be created for play during a master station page. The message should be configured
per the screen below. When this message is active the AMI will play a silent tone. Note the message
priority must be set to the highest priority to enable the master stations pages to override any active
alarms or telephone pages (if applicable).
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 15 of 22
Inputs Screen
1. Inputs one through seven must have the Continuous Audio Message box selected. This allows the
message to play while the input is active and stop when the input is inactive. Input control lines are
supplied from the M/I cabinet’s external interface PCBA. A reset input to the AMI is not required.
See screenshot below for example of INPUT 1. Duplicate these settings for inputs two through seven.
2. Change the Current Output Combination to None. This will prevent the AMI auxiliary output one
from activating during an alarm. This output should only activate during a telephone page (if
applicable).
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 16 of 22
INPUT 8 must be configured the same as one through seven except it must be set to activate the Master
Station Page message created in the previous step. The screen shot below shows the correct settings for
input 8.
For additional features regarding the AMI alarm messages, refer to help screens supplied with the AMI
programming software. The changes noted above are the minimum changes required to allow AMI alarm
activation from the MI05 Series Merge/Isolate Cabinets.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 17 of 22
Outputs Screen
Select the Follow Event box for OUTPUT 1. This output will be active during telephone paging and
return to the inactive state when the page is ended. The M/I cabinet will merge all zones during the
telephone page as a result of the active output.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 18 of 22
Telephone Interface Screen
The Announcement Output Combination must be set to Output 1. This will cause output one to
activate while telephone paging is active. The M/I cabinet will merge all zones during the telephone page
as a result of the active output. Also the Pre-Announcement Tone and Telephone Paging Priority
must be set to the lowest priority to prevent telephone pages from interfering with alarms or master
station pages.
For additional features regarding the AMI telephone interface, refer to help screens supplied with the
AMI programming software. The changes noted above are the minimum changes required to allow the
telephone paging access to the MI05 Series Merge/Isolate Cabinets.
Using the Model 12584-001 AMI I/O Expansion Module
If using the Model 12584-001 I/O Expansion Module with the AMI for additional alarm inputs, the input
screen for each input; 9–40, must be programmed.
1. First, program the input Switch Type and the Current Message to be activated by the input.
2. Next, program the Current Output Combination to OUTPUT 1. This will cause output one to
activate while the input is active. The M/I cabinet will merge all zones during the alarm message as a
result of the active output.
Inputs 9–40 are independent of the master station and will be automatically broadcast to all zones of the
system. The following screen is an example of INPUT 9. The remaining inputs; 10–40, must be
programmed in the same fashion if used.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 19 of 22
Model MI05-104 Merge/Isolate Cabinet
Model GTK99019 Audio Interface
1. Mount the Model GTK99019 Audio Interface in accordance with GAI-Tronics Pub. K99019iom,
which is packaged with the equipment.
2. Connect TB1 of the audio interface to the 120 V ac power source using 3-conductor, No. 14 AWG ac
power cable. Power requirements for this interface are 120 V ac, 50/60 Hz at 0.2 A.
3. Connect the audio interface to the Model MI05-104 Merge/Isolate Cabinet’s external interface PCBA
as follows using a four-pair, No. 18–20 AWG cable. Refer to Figure 5.
Table 11. Audio Interface to M/I Cabinet Connections
Function
Audio Interface
Terminals
Connect
to
M/I Cabinet’s External
Interface PCBA
Page Line
TB2-4 and TB2-5
TB2-1 and TB2-2
Party Line
TB2-6 and TB2-7
TB2-3 and TB2-4
All-Call Control Lines
TB2-14 and TB2-15
TB2-7 and TB2-8
Page Override Control Lines
TB2-16 and TB2-17
TB2-5 and TB2-6
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 20 of 22
Figure 5. Model GTK99019 Audio Interface Connection Diagram
Model D99001-VLCX Volume Level Control Transmitter Kit
Install the Volume Level Control Transmitter Kit as follows:
1. Mount the VLC transmitter PCBA to the cabinet panel just above the external interface PCBA. Refer
to Figure 2 for location of the external interface PCBA. The panel contains stand-offs for mounting
the VLC transmitter. Mounting screws are provided with the kit.
2. Plug the VLC transmitter PCBA cable assembly into J5 on the external interface PCBA.
Operation
The Model MI05-104 Merge/Isolate Cabinet’s functions are controlled by one or more Model MS05-101
Master Stations. The cabinet allows the master stations to selectively merge any combination of zones or
all zones for paging and party line communication. The cabinet also allows the master stations to make
voice pages to any combination of zones or all zones simultaneously. A detailed description of the master
station controls are outlined in the manual that is packaged with the master station.
External accessories can be added to the cabinet to expand the system operation. To accommodate the
additional devices using the page line, a priority scheme is used. There are a total of three levels of
priorities. If more than one device attempts to broadcast audio on the page line, only the audio from the
highest priority device will be broadcast from the paging speakers. The following priorities are assigned
(1 being the highest) and can not be altered:
1. Master Stations
2. Alarms
3. Page/Party® stations, Telephone Interface, and Audio Interface
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Model MI05-104 Merge/Isolate Cabinet
Pub. MI05-104iom.6
Page 21 of 22
Other Features
Call-In
The call-in feature is used as a means to contact the master station. When a Page/Party® handset station in
any zone goes off-hook on party line one, the yellow LED indicator on the master station illuminates and
a sonalert sounds. When the operator answers the call, the sonalert is turned off.
Page Monitor
The page line from any or all zones can be monitored via an integral speaker at the master station. When
the master station operator presses a zone push button, pages from that zone are heard from the master
station’s speaker. The operator can monitor more than one zone by selecting any combination of zone
push buttons.
Accessories
Model 10959-201 Audio Messenger Interface (AMI)
The Model 10959-201 Audio Messenger Interface (AMI) produces alarms or warning tones to alert
people of emergency conditions. The AMI can generate seven prioritized alarm tones, selected from a
default library of tones. Custom tones or messages can also be stored on the AMI for playback. These
tones/messages are activated by either the external field switches or by master stations. If an alarm is
activated from a field switch, the alarm is broadcast to all zones. If an alarm is activated from a master
station, the alarm can be broadcast to any zone, combination of zones or all zones.
NOTE: All alarm tones must be reset by the master station.
Detailed programming options and operation are explained in GAI-Tronics Pub. 42004-403 for the Model
10959-201.
Model 10959-203 Audio Messenger with Telephone Interface
The Model 10959-203 provides all of the same functions as the 10959-201 described above, but also
allows individuals to access the system page and party line using a standard telephone. Voice paging and
party line conversations are supported; however, this feature does not support dial out access from the
Page/Party® stations. By dialing a predetermined extension, the telephone caller can broadcast a page
over the system speakers in all zones and converse on party line five.
Detailed programming options and operation are explained in GAI-Tronics Pub. 42004-403 for the Model
10959-203.
Model GTK99019 Merge/Isolate Audio Interface
The Model GTK99019 Merge/Isolate Audio Interface allows access to the Page/Party® system from a
remote device. Access to the page line and party line four is supported. Possible applications for this
interface include broadcasting an external audio source over the paging speakers. One-way or two-way
radio communication between the Page/Party® handset stations and an external radio system is another
possible application.
Detailed operation is explained in the instructions provided in GAI-Tronics Pub. K99019iom.
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17
Pub. MI05-104iom.6
Page 22 of 22
Model MI05-104 Merge/Isolate Cabinet
Model D99001-VLCX Volume Level Control Transmitter
The VLC transmitter is activated when a voice page is generated from the master station. When active,
the transmitter produces a signal on the page line that activates remote devices that are set to monitor the
page line.
Typical applications of the VLC transmitter include:
Activating speaker amplifiers in locations such as conference rooms or crew’s quarters, where the
broadcasting of operational pages is unnecessary.
Activating strobes or other external signaling devices.
Increasing output to speakers and disabling handset page capabilities at Page/Party® field stations
equipped with VLC receivers.
Maintenance
If the equipment requires service, contact your Regional Service Center for a return authorization number
(RA#). Equipment should be shipped prepaid to GAI-Tronics with a return authorization number and a
purchase order number. If the equipment is under warranty, repairs or a replacement will be made in
accordance with GAI-Tronics’ warranty policy. Please include a written explanation of all defects to
assist our technicians in their troubleshooting efforts.
Call 800-492-1212 inside the USA or 610-777-1374 outside the USA for help identifying the Regional
Service Center closest to you.
Supplemental Information
Reference Documentation

73539
No. MI05-104 5-Zone Merge/Isolate Cabinet Outline and Mounting Details

73540
No. MI05-104 5-Zone Merge/Isolate Cabinet Interconnection Diagram

42004-403
Model 10959-201 and -203 Wall-Mount Audio Messenger Interfaces (AMI)

K99019iom
Model GTK99019 Merge/Isolate Audio Interface Manual
Spare Parts
Part No.
Description
12584-003
Master I/O Controller
69281-001
Termination PCBA
69282-001
Audio Switching PCBA
69283-001
Page Monitor PCBA
69284-001
External Interface PCBA
69221-902
Off-Hook Detection PCBA
69410-001
Audio Isolation PCBA
I:\Opnotes -- Released\MI05-00x Merge-Isolate Cabs\MI05-104\MI05-104iom6.docx
02/17