Fall 201
CONTINUOUS IMPROVEMENT HAS ITS REWARDS
Key Features & Benefits:

Universal Anemometer Channels

• Six digital channels accomodate the
• Flex channels configure automatically
anemometer brand of your choice.
• Digital channels do not require
SCM cards.

One-second Sample Rate
• Conforms to IEC 61400-12-1.
Three ‘Flex’ Channels
based on SCM installed.
• Allows for numerous sensor
configuration options.

Password Protected Access
• Unauthorized user lockout prevents
access to logger via the keypad.
Global leader in wind measurement technology®
Complete Systems
| Sensors | Remote Sensors | Tilt-Up Towers | Data Loggers | Turbine Control
© 2011 NRG Systems, Inc.
05/2011
| NRG Systems, Inc. | Hinesburg, Vermont 05461 USA | 802.482.2255
Symphonie® and SymphoniePLUS® are trademarks of NRG Systems, Inc., and may be registered in the U.S. Patent and Trademark Office and in other countries.
SymphoniePLUS®3
Configuration
15-channel data logger
User interface
• Liquid Crystal Display (LCD) 4 x 20 characters
• 16 key pad (6 navigation keys plus numeric/phone pad) with
Configurable
parameters
• Clock
• Time zone
• Site number
• Display scaling (defaults are provided for each channel based
iPack options
• iPack configured via serial port connection to your PC
• Serial connection direct to iPack or through logger's iPack
audible feedback
Specifications
on channel type)
Description
15 channel internet-enabled wind energy data logger
access port
• Wind resource assessment
• Turbine power performance verification
Sensor compatibility - • NRG #40C anemometer
counter channels
• Rain gauge
• Opto anemometer
• Reed switch anemometer
Sensor compatibility - • NRG Systems #200P direction vane
analog channels
• NRG Systems #110S temperature sensor
• Li-Cor #200SZ pyranometer
• NRG Systems #BP20 absolute pressure
Counter channels
Analog channels
Flex channels
• Symphonie Data Retriever for Windows integrates iPack
settings
Connections
File format
Software
Reader
Data delivery
Expansion slots
• Three (3) ‘Flex’ SCM slots accept analog or counter (digital)
SCMs
(requires optional iPack power)
• RH-5X relative humidity
(requires optional iPack power)
Channels 1-3 and 13-15 are counter (digital) inputs
• Channels 1-3 and 13-15 are pre-programmed for
NRG #40C anemometers or compatible sensors
• Maxumum counter input frequency: 2500 Hz
Channels 7-12 are analog inputs
• Channels 7 and 8 are dedicated for NRG #200P direction vane
• Channels 9-12 use analog Signal Conditioning Modules (SCMs)
to configure each channel for a particular sensor
Channels 4-6 are ‘Flex’ channels
• Analog or counter (digital) inputs
• Accept Signal Conditioning Modules (SCMs) to configure the
channel for a particular sensor type
• Four (4) SCM slots accept only analog SCMs
Communication ports • Male DB25 interfaces to one optional iPack communications
One second
10 minute, fixed
Internal battery-backed
SD Card, non-volatile FLASH
672 files
Installation
module
• iPack access port provides a connection to the iPack
programming port without dismounting the iPack or logger
Power requirements
Batteries
• Two (2) 1.5 Volt D-Cell Batteries (included)
• Nominal voltage: 1.5 Volts
• Minimum voltage: 0.9 Volts
• Battery life approximately one year, depending on
configuration
External power input
External solar input
Other
• Provided by an optional iPack
• Provided by an optional iPack
• Optional iPacks provide 12V power required by some sensors
• PV/Battery Only iPack provides power to sensors and logger
for stand alone configurations
• Mounts with 4 bolts (included) to keyed slots inside of metal
Tools required
• Shelter box mounts to tower with hose clamps
• Screwdriver for input terminals, included
• 8 mm (5/16 inch) wrench or nut driver for logger mounting
screws and ground nuts
Each data interval is time/date-stamped:
• Average
• Standard deviation
• Min*
• Max*
*min and max not used for wind direction vanes
• Windows compatible
• (1) 14 KB binary file per day
• Header includes site, serial number and sensor information
Symphonie Data Retriever for Windows
• Scales raw data
• Creates measurement database for each site
• Creates basic reports
• Maintains site and sensor information
• Configures iPacks
Windows compatible SD Card reader
• SD Cards
• Internet email via GSM, CDMA, or Iridium Satellite with
optional iPack
0.1% of full scale (1024 counts)
0.1% of the value stored
0.1% of the value stored
0.4% of the value stored
4% of the value stored
Mounting
shelter box
Environmental
Operating
temperature range
Operating humidity
range
Lifespan
-40°C to 65°C (-40°F to 149°F)
Note: display readable -30°C to 55°C (-22°F to 130°F)
0 to 100% RH non-condensing
10 years +
Physical
Weight
Dimensions
1.3 kg (2.6 pounds), including batteries
22.2 cm (8.7”) h x 18.8 cm (7.4”) w x 7.7 cm (3.0”) d,
including field wiring panel
Materials
Faceplate
Buttons
Wiring panel
Enclosure
Resolution
Analog measurement
Counter average
Analog average
Min / Max stored
Standard deviation
• Sensors connect to removeable field wiring panel
• Field wiring panel plugs into logger
• Ground stud connects to earth ground with included ground
cable
Data Collection
Sampling interval
Averaging interval
Real time clock
Storage medium
Maximum data
storage
Parameters
recorded for each
channel
Sensor wiring
Injection molded black ABS
White elastomer dome keypad
Fiberglass-epoxy terminal board, sealed gold plated pins, zinc
plated screws and terminals
Weatherproof polycarbonate, meets the following specifications:
• NEMA type 4, 4X and 13
• IEC: IP65
Ordering Information

SHIPPING Fall 2011

Contact NRG Systems’ Sales, 802-482-2255
110 Riggs Road, Hinesburg, Vermont 05461 USA
|
sales@nrgsystems.com
Printed on 100% post-consumer waste recycled paper manufactured using wind power. © 2011 NRG Systems, inc.
Instrument type