INSTALLATION AND OPERATION MANUAL
FVT/FVR40D2I1C4E
4-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO
+ 2 BI-DIRECTIONAL DATA + AIPHONE™ INTERCOM
+ 4 CONTACT CLOSURE
+ 100MB ETHERNET
+ REDUNDANT POINT-TO-POINT DUAL SFP OPTICAL PORTS
The FVT/FVR40D2I1C4E series utilize 10-bit digital video encoding and decoding
for high-quality video transmission that meets the requirements of EIA RS-250C
for short-haul video transmission. These environmentally hardened units provide
transmission of four independent video channels and two bi-directional data
channels. They also provide transmission of one Aiphone™ intercom channel and
four contact closure channels with tamper supervision in addition to one 10/100Mb
Ethernet channel.
The ComNet™ FVT/FVR40D2I1C4E has dual optical (SFP) ports to provide a redundant
point-to-point fail safe topology in the event of loss of one fiber or one optical module.
Operational status can be monitored by using the web management interface
through the addition of the ComNet network managed chassis and network
management interface module.
Bi-color (red/green) LED indicators are provided for confirming operating status in
addition to alarm contacts for fault monitoring. See Figure 15 on Page 9 for LED
explanations.
Packaged in the exclusive ComNet ComFit housing, these units may be either wall
or rack-mounted (using ComNet C2 network-managed rack), or may be DIN-rail
mounted by the addition of ComNet model DINBKT1 adaptor plate. See Figure A on
Page 10 for mounting instructions.
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 1
INSTALLATION AND OPERATION MANUAL
FVT/FVR40D2I1C4E
FIGURE 1 – FVT/FVR40D2I1C4E TRANSMITTER AND RECEIVER
Optical fiber determined by Selection of Small Form-factor Pluggable (SFP) modules*.
12
3
(–)BLACK
ON
POWER
VIDEO IN
+Vin
(+) BLACK W/ WHITE
STRIPE
S4
10/100 LINK
GND
PWR2
10/100
DATA2
(–)BLACK
IN
OUT
PWR1
12
S3
NETWORK
VIDEO 4
IN
OUT
DATA 1
DATA1
4
S2
VIDEO 2
VIDEO 3
DATA 2
LE-D
LE-F
ALARM
2
AIPHONE CONTACT
S1
12
SFP2
SFP1
VIDEO 1
12
SFP2
C
S
CONTACT
MANAGEMENT
SFP1
1
FVT40D2I1C4E
4 CH VIDEO TX +
2 CH BI-DIR DATA +
4 CH CONTACT +
1 CH ETHERNET
GND
+Vin
(+) BLACK W/ WHITE
STRIPE
Power Supply:
Dual 8-24VDC @ 4W
Rack Mount: C2 Network-Managed
* One SFP required for point-to-point operation. Two SFPs required for redundant operation.
Consult factory for compatible SFP Modules.
NOTE: Remove PWR1 Electrical
Connector for Rack Mount Units
FIGURE 2 – FVT40D2I1C4E TRANSMITTER
FIGURE 3 – FVR40D2I1C4E RECEIVER
FRONT PANEL
FRONT PANEL
REAR PANEL
FVT40D2I1C4E
FVR40D2I1C4E
4 CH
4 CH VIDEO RX
+ VIDEO TX +
2 CH+BI-DIR DATA +
2 CH BI-DIR DATA
4
CH
4 CH CONTACT + CONTACT +
1 CH ETHERNET
1 CH ETHERNET
TECH SUPPORT: 1.888.678.9427
+Vin
GND
+Vin
+Vin
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 2
1
3
4
PWR2
GND
PWR1
GND
2
1
+Vin
PWR2
4
3
VIDEO IN
2
AIPHONE CONTACT
VIDEO OUT
DATA 2
DATA 1
AIPHONE CONTACT
DATA 2
GND
PWR1
S4
ON
DATA 1
IN
OUT
MANAGEMENT
DATA2
10/100 LINK
POWER
S3
NETWORK
+Vin
VIDEO 4
IN
OUT
MANAGEMENT
GND
DATA1
NETWORK
1
3
+Vin
PWR1
GND
PWR2
4
VIDEO 3
12
S4
ON
2
VIDEO IN
AIPHONE CONTACT
DATA 2
DATA 1
IN
OUT
MANAGEMENT
DATA2
S2
VIDEO 2
12
12
S4
10/100 LINK 10/100 LINK
ON
POWER
POWER
S3
S1
LE-D
LE-F
ALARM
10/100
10/100
IN
OUT
OUT
SFP2
SFP1
VIDEO 1
ETHERNET
12
DATA2
12
ETHERNET
10/100
12
ETHERNET
S3
DATA1
SFP2
C
S
CONTACT
12
VIDEO 4
VIDEO 3OUT
DATA1 4
VIDEO
SFP1
12
VIDEO 3
S1
LE-D
LE-D
LE-F
SFP2LE-F
ALARM
ALARM
SFP1
VIDEOS2
1
S2
VIDEO 2IN
IN
12
VIDEO 2
S1
SFP2
C
S
CONTACT
12
12
SFP2
SFP1
VIDEO 1
12
SFP2
SFP1
C
S
CONTACT
FVR40D2I1C4E
4 CH VIDEO RX +
2 CH BI-DIR DATA +
4 CH CONTACT +
1 CH ETHERNET
NETWORK
SFP1
REAR PANEL
INSTALLATION AND OPERATION MANUAL
FVT/FVR40D2I1C4E
FIGURE 4 – RJ45 BREAK-OUT – FVT40D2I1C4E TRANSMITTER
4 pc. Factory Supplied
RJ-45 PORTS
D (DATA PORTS)
Located on Rear Panel
DATA 1
DATA 2
D
D
AIPHONE CONTACT
K
A
C
NT
+Vin
GND
VIDEO IN
VIEW INSIDE RJ-45 PORT
PWR2
4
3
2
PIN # Wire Color
Data Connections
1
Blue
DATA OUT –
2
Orange
DATA OUT +
3
Black
DATA IN +
4
Red
RELAY OUT
5
Green
RELAY OUT
6
Yellow
DATA IN –
7
Brown
GND
8
White
+5V (BIAS)
1
C (CONTACT PORT)
PIN # Wire Color
RJ-45 BREAK-OUT KIT
Screw Number Corresponds to RJ-45 Port Pin Number
TX Connections
1
Blue
IN 1+
2
Orange
IN 1–
3
Black
IN 2+
4
Red
IN 3+
5
Green
IN 3 –
6
Yellow
IN 2–
7
Brown
IN 4+
8
White
IN 4–
A (AIPHONE™ PORT)
PIN # Wire Color
TECH SUPPORT: 1.888.678.9427
Aiphone Connections
1
Blue
LE-D ‘-’ TERMINAL
2
Orange
LE-D ‘1’ TERMINAL
3
Black
LE-D ‘E’ TERMINAL
4
Red
RELAY OUTPUT COM
5
Green
RELAY OUTPUT N.C.
6
Yellow
RELAY OUTPUT N.O.
7
Brown
GND
8
White
GND
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 3
INSTALLATION AND OPERATION MANUAL
FVT/FVR40D2I1C4E
FIGURE 5 – RJ45 BREAK-OUT – FVR40D2I1C4E RECEIVER
4 pc. Factory Supplied
RJ-45 PORTS
D (DATA PORTS)
Located on Rear Panel
DATA 1
DATA 2
D
D
AIPHONE CONTACT
K
A
C
NT
+Vin
GND
VIDEO IN
VIEW INSIDE RJ-45 PORT
PWR2
4
3
2
PIN # Wire Color
Data Connections
1
Blue
DATA OUT –
2
Orange
DATA OUT +
3
Black
DATA IN +
4
Red
RELAY OUT
5
Green
RELAY OUT
6
Yellow
DATA IN –
7
Brown
GND
8
White
+5V (BIAS)
1
C (CONTACT PORT)
PIN # Wire Color
RJ-45 BREAK-OUT KIT
Screw Number Corresponds to RJ-45 Port Pin Number
RX Connections
1
Blue
OUT1 +
2
Orange
OUT1 –
3
Black
OUT2 +
4
Red
OUT3 +
5
Green
OUT3 –
6
Yellow
OUT2 –
7
Brown
OUT4 +
8
White
OUT4 –
A (AIPHONE™ PORT)
PIN # Wire Color
Aiphone Connections
1
Blue
LEF ‘E’ TERMINAL
2
Orange
LEF ‘1’ TERMINAL
3
Black
LEF ‘–’ TERMINAL
4
Red
NC
5
Green
CONTACT INPUT +
6
Yellow
NC
7
Brown
GND
8
White
GND
NC = No Connection
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 4
1 12 2
1 12 2
10/100
10/100
LE-D
LE-D
LE-F
P2
INSTALLATION
AND OPERATION MANUAL
FVT/FVR40D2I1C4E
P2
ALARMLE-F
P1
ALARM
P1
O1
S2
O 1 FIGURE 6 S2
– DATA SWITCH POSITIONS
O 2 The mode for each IN
data channel is configured using a set of two switches labeled DATA1 (S3) and DATA2 (S4), located on the front panel of the unit.
O2
IN
OUT
O3
O3
DATA1 OUT
O4
DATA1
DATA1 (S3) DATA2 (S4)
O4
S3
1
2
1
2
Resulting Mode
S3
ON
ON
ON
ON RS232
IN
ON
OFF
OFF RS422, Bi-Phase or Manchester
IN
ON
OUT
OFF
ON
OFF
ON RS485 2-Wire, Sensornet
DATA2 OUT
OFF OFF OFF OFF RS485 4-Wire
DATA2
S4
S4
0 LINK
ON
0 LINK
ON
ER
ER
1 12 2
FIGURE 7 – RJ-45 PIN OUT
PIN # Wire Color
PIN # RS232
Data Connections
1
Blue
DATA OUT –
2
Orange
DATA OUT +
3
Black
DATA IN +
4
Red
RELAY OUT
5
Green
RELAY OUT
6
Yellow
DATA IN –
7
Brown
GND
8
White
+5V (BIAS)
RS422
RS485 2-Wire
RS485 4-Wire
1
NC
RS422 OUTPUT –
NC
RS485 OUTPUT –
2
RS232 – OUTPUT
RS422 OUTPUT +
NC
RS485 OUTPUT +
3
NC
RS422 INPUT +
RS485 INPUT +
RS485 INPUT +
4
RELAY OUT
RELAY OUT
RELAY OUT
RELAY OUT
5
RELAY OUT
RELAY OUT
RELAY OUT
RELAY OUT
6
RS232 – INPUT
RS422 INPUT –
RS485 INPUT –
RS485 INPUT –
7
GND
GND
GND
GND
8
+5V (BIAS)
+5V (BIAS)
+5V (BIAS)
+5V (BIAS)
NC = No Connection
TECH SUPPORT: 1.888.678.9427
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 5
INSTALLATION AND OPERATION MANUAL
FVT/FVR40D2I1C4E
FIGURE 8 – DATA CONNECTIONS
See Page 5 for Switch Settings
RS232
RS422
Bi-phase or
Manchester
2-Wire
RS485,
Sensornet
4-Wire
RS485
Customer
Equipment
FVT40D2I1C4E
FVR40D2I1C4E
Customer
Equipment
Data Transmit
DIN(-)
DOUT(+)
Data Receive
Data Receive
DOUT(+)
DIN(-)
Data Transmit
Signal Ground
GND
GND
Signal Ground
Data Out (+)
Data In (+)
DIN(+)
DOUT(+)
Data Out (-)
DIN(-)
DOUT(-)
Data In (-)
Data In (+)
DOUT(+)
DIN(+)
Data Out (+)
Data In (-)
DOUT(-)
DIN(-)
Data Out (-)
Data In (+)
DOUT(+)
DIN(+)
Data Out (+)
Data In (-)
DOUT(-)
DIN(-)
Data Out (-)
Data (A)
DIN(+)
DIN(+)
Data (A)
Data (B)
DIN(-)
DIN(-)
Data (B)
Data Out (A)
DIN(+)
DOUT(+)
Data In (A)
Data Out (B)
DIN(-)
DOUT(-)
Data In (B)
Data In (A)
DOUT(+)
DIN(+)
Data Out (A)
Data In (B)
DOUT(-)
DIN(-)
Data Out (B)
FIGURE 9 – POSSIBLE ETHERNET CONFIGURATION
Ethernet IEEE 802.3 Network Element determined by user.
Optical Fiber
SC or LC
Connectors
SINGLE FIBER
SFP MODULE
CAT5e/6 with
RJ45 Connections
Ethernet IEEE 802.3
Network Element
TECH SUPPORT: 1.888.678.9427
CAT5e/6 with
RJ45 Connections
FVT40D2I1C4E
FVR40D2I1C4E
Ethernet IEEE 802.3
Network Element
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 6
INSTALLATION AND OPERATION MANUAL
FVT/FVR40D2I1C4E
FIGURE 10 – SFP CONNECTIONS
Number of fibers and type of fiber connectors will be determined by selected SFP modules and if point-to-point or redundant modes are required.
FVR40D2I1C4E
4 CH VIDEO RX +
2 CH BI-DIR DATA +
4 CH CONTACT +
1 CH ETHERNET
DATA1
VIDEO 4
DATA1
VIDEO 4
12
IN
OUT
10/100 LINK
ON
AIPHONE CONTACT
IN
OUT
S3
DATA2
12
12
S4
10/100
10/100
POWER
VIDEO 3
ETHERNET
12
ETHERNET
10/100 LINK
S2
VIDEO 2
IN
OUT
S3
DATA2
LE-D
LE-F
ALARM
12
S2
VIDEO 2
VIDEO 3
SFP2
SFP1
VIDEO 1
S1
DATA 2
SFP2
C
S
CONTACT
12
S1
LE-D
LE-F
ALARM
12
SFP2
SFP1
VIDEO 1
12
SFP2
SFP1
C
S
CONTACT
DATA 1
SFP1
IN
OUT
S4
NETWORK
FVT40D2I1C4E
4 CH VIDEO TX +
2 CH BI-DIR DATA +
4 CH CONTACT +
1 CH ETHERNET
ON
POWER
FIGURE 11 – AIPHONE™ INTERCOM CONNECTIONS
The units are designed to operate with the Aiphone™ LE-D and LEF intercom system.
FVT40D2I1C4E
PIN # Wire Color
LE-D
FVR40D2I1C4E
Aiphone Connections
PIN # Wire Color
Aiphone Connections
1
Blue
LE-D ‘-’ TERMINAL
1
Blue
LEF ‘E’ TERMINAL
2
Orange
LE-D ‘1’ TERMINAL
2
Orange
LEF ‘1’ TERMINAL
3
Black
LE-D ‘E’ TERMINAL
3
Black
LEF ‘–’ TERMINAL
4
Red
RELAY OUTPUT COM
4
Red
NC
5
Green
RELAY OUTPUT N.C.
5
Green
CONTACT INPUT +
6
Yellow
RELAY OUTPUT N.O.
6
Yellow
NC
7
Brown
GND
7
Brown
GND
8
White
GND
8
White
GND
FVT40D2I1C4E
FVR40D2I1C4E
LEF
E
3
3
–
1
2
2
1
–
1
1
E
5
TECH SUPPORT: 1.888.678.9427
4
6
Form ‘C’ Relay
Output
Door/Barrier
Contact Input
5
7
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 7
2
CH VIDEO TX +
O
CH2 BI-DIR DATA IN
+
INSTALLATION
AND OPERATION MANUAL
OCH
3 CONTACT +OUT
CH ETHERNET
DATA1
O4
10/100
S3
The mode for contact closure operation is configured using a set of two switches labeled CONTACT (S1) located on the front panel of the unit. There are four
Cin the forward (video) direction.
supervised contactsIN
S
OUT
CONTACT
DATA2
S1
S4
CONTACT (S1)
1122
FP2
FIGURE 12 – CONTACT SWITCH POSITIONS
12
FP1
12
0 LINK
LE-D
ON
LE-F
P2
ER
ALARM
P1
NOTE: These switch settings refer to the transO1
mitter (FVT40D2I1C4E).
On the receiver
S2
O2
O3
(FVR40D2I1C4E), S1 SWITCH 1 inverts the
IN S1 SWITCH 2 is not used.
contact outputs.
DATA1
O4
OUT
1
2
Resulting Mode
ON
ON
Full Supervision – When a 1K resistor is connected in series with
the contact closure input, and a 1K resistor is connected in parallel
across the contact closure input. Both open circuits and short
circuits can be detected as well as normal opens and closes.
ON
OFF
Series Supervision – When a 1K resister is connected in series with
the contact closure input. In this mode, shorts across the contact
inputs can be detected but open circuits cannot be detected.
OFF
ON
Parallel Supervision – When a 1K resistor is connected in parallel
across the contact closure input. In this mode, open circuits can be
detected but short circuits cannot be detected.
OFF
OFF
No Supervision – The contacts will behave as normal contacts with
no Supervision.
12
S3
10/100
DATA2
IN
OUT
12
FIGURE 13S4
– CONTACT CLOSURE SUPERVISED INPUT CIRCUIT
0 LINK
ER
FVT/FVR40D2I1C4E
ON
INTERNAL
5V
1K Series*
1K
1K
Parallel*
1K
TECH SUPPORT: 1.888.678.9427
* Optional external resistors
(provided) are required for
supervision. Place close to
the switch for optimal results.
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 8
2
O2
O3
10/100
FVT/FVR40D2I1C4E
FIGURE 14S1
– ALARM SWITCH POSITIONS
S3
The mode for alarm operation is configured using a set of two switches labeled ALARM (S2) located on the front panel of the unit. There are two alarm outLE-D
puts on each unit. One
on each RJ45 data connector. See Figures 4 & 5 on Pages 3 & 4.
IN
1122
P2
P1
O1
1122
O4
FP2
C
IN
INSTALLATION
AND OPERATION MANUAL
S
OUT
CONTACT
DATA1
O
2
0 LINK
O
ER3
LE-F
OUT
ALARM
DATA2
S2
S4
ON
DATA1
O4
ALARM (S2)
12
10/100
2
ON
ON
Alarm 1 – SFP 1 Failure
Alarm 2 – SFP 2 Failure
ON
OFF
Alarm 1 – SFP 1 or SFP 2 Failure
Alarm 2 – Video Loss
OFF
ON
Alarm 1 – SFP 1 Failure or Video Loss
Alarm 2 – SFP 2 Failure or Video Loss
OFF
OFF
Alarm 1 – SFP 1 or SFP 2 Failure or Video Loss
Alarm 2 – SFP 1 or SFP 2 Failure or Video Loss
IN
OUT
S3
DATA2
1
IN
OUT
Resulting Mode
NOTE: The ALARM will also open when Fiber Link on either SFP port is lost or if Power is lost on either unit.
Video Loss alarm requires the loss of all 4 video channels in order to trigger the alarm.
12
S4
FIGURE 15 – LED INDICATORS
0 LINK
ON
No optical link
Link is good and is in use
Link is good but is not in
use
No video signal
An active video
signal is present
–
No Ethernet signal
Ethernet signal linked
–
Fiber link failed
All four contacts
are closed
–
Supervised contact alarm
or fiber link failed
No supervised contacts in
alarm state
–
LE-D –
Quiet / No Audio
Audio Present
Call button active
LE-F –
Quiet / No Audio
Audio Present
–
DATA IN Tri-state
Low state
High state
Data activity
DATA OUT Tri-state
Low state
High state
Data activity
Unit powered up
–
One or more contacts are
open
IN
OUT
DATA1
S2
LE-D
LE-F
ALARM
–
GREENSolid: Link (no activity)
Blinking: Activity
Off: No link
TECH SUPPORT: 1.888.678.9427
VIDEO 4
12
VIDEO 2
12
SFP2
SFP1
VIDEO 1
S1
12
SFP2
C
S
CONTACT
POWER Unit powered down
SFP1
FVT40D2I1C4E
4 CH VIDEO TX +
2 CH BI-DIR DATA +
4 CH CONTACT +
1 CH ETHERNET
CONTACT (S) –
VIDEO 3
CONTACT (C)
12
10/100
YELLOW Solid: Highest data rate (100Mbs)
POWER
10/100 LINK –
10/100 LINK
VIDEO –
DATA2
SFP SFP not installed
ON
FLASHING
S4
GREEN
IN
OUT
OFF
S3
RED
ER
ETHERNET
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 9
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units
should be installed in dry locations protected from extremes of
temperature and humidity.
FIGURE A
Dimensions are for a standard ComNet™ two slot module
C2 NETWORK MANAGED RACKS
.156 [3.96 mm]
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, ComNet recommends that the
power supply be turned off and that the rack power supply is disconnected
from any power source. Note: Remove electrical connector before
installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the
card guides in the rack until the edge connector at the back of the card
seats in the corresponding slot in the rack’s connector panel. Seating
may require thumb pressure on the top and bottom of the card’s front
panel.
CAUTION: Take care not to press on any of the LEDs.
.313 [7.95 mm]
2. Tighten the two thumb screws on the card until the front panel of the
card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 power supply.
IMPORTANT SAFEGUARDS:
A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may
be greater than room ambient. Therefore, consideration should be given to
installing the equipment in an environment compatible with the maximum
ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not
compromised.
3 CORPORATE DRIVE | DANBURY, CT 06810 | USA
T: 203.796.5300 | F: 203.796.5303 | TECH SUPPORT: 1.888.678.9427 | INFO@COMNET.NET
8 TURNBERRY PARK ROAD | GILDERSOME | MORLEY | LEEDS, UK LS27 7LE
T: +44 (0)113 307 6400 | F: +44 (0)113 253 7462 | INFO-EUROPE@COMNET.NET
© 2018 Communications Networks Corporation. All Rights Reserved. “ComNet” and the “ComNet Logo” are registered trademarks of Communication Networks, LLC.
INS_FVT/FVR40D2I1C4E_REVA 06/22/12 PAGE 10
Download PDF