INSTALLATION INSTRUCTIONS
Instrucciones de instalación
Installationsanleitung
Instruções de Instalação
K1S100
Istruzioni di installazione
Installatie-instructies
Instructions d´installation
K1S200
Slat Wall Monitor Arms
Spanish Product Description
German Product Description
Portuguese Product Description
Italian Product Description
Dutch Product Description
French Product Description
K1S100/200
K1S100/200
Installation Instructions
DISCLAIMER
Milestone AV Technologies and its affiliated corporations and
subsidiaries (collectively "Milestone"), intend to make this
manual accurate and complete. However, Milestone makes no
claim that the information contained herein covers all details,
conditions or variations, nor does it provide for every possible
contingency in connection with the installation or use of this
product. The information contained in this document is subject
to change without notice or obligation of any kind. Milestone
makes no representation of warranty, expressed or implied,
regarding the information contained herein. Milestone assumes
no responsibility for accuracy, completeness or sufficiency of
the information contained in this document.
Chief® is a registered trademark of Milestone AV Technologies.
All rights reserved.
IMPORTANT SAFETY INSTRUCTIONS!
WARNING: A WARNING alerts you to the possibility of
serious injury or death if you do not follow the instructions.
CAUTION: A CAUTION alerts you to the possibility of
damage or destruction of equipment if you do not follow the
corresponding instructions.
WARNING: Failure to read, thoroughly understand, and
follow all instructions can result in serious personal injury,
damage to equipment, or voiding of factory warranty! It is the
installer’s responsibility to make sure all components are
properly assembled and installed using the instructions
provided.
WARNING: Failure to provide adequate structural strength
for this component can result in serious personal injury or
damage to equipment! It is the installer’s responsibility to
make sure the structure to which this component is attached
can support five times the combined weight of all equipment.
Reinforce the structure as required before installing the
component.
WARNING: Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located between the K1S100/200 Monitor
Arm up to (and including) the display does not exceed 25 lbs
(11.34 kg) per arm. Use with products heavier than the
maximum weight indicated may result in collapse of the
mount and its accessories causing possible injury.
WARNING: Use this mounting system only for its intended
use as described in these instructions. Do not use
attachments not recommended by the manufacturer.
2
WARNING: Never operate this mounting system if it is
damaged. Return the mounting system to a service center for
examination and repair.
WARNING: Do not use this product outdoors.
--SAVE THESE INSTRUCTIONS--
Installation Instructions
K1S100/200
DIMENSIONS
K1S100
75
2.953
QUICK RELEASE
VESA INTERFACE
PITCH RANGE
10° DOWN
75° UP
±90° INTERFACE
ROTATION
CABLE
PITCH TENSION
ADJUSTMENT
HEIGHT
ADJUSTMENT
[235.1±165.1]
9.26±6.5
K1S200
MAXIMUM WIDTH OF 2 PARALLEL, FORWARD-FACING DISPLAYS: 34.92 " [887]
QUICK CONNECT
VESA INTERFACE
3.937
2.953
90 INTERFACE
ROTATION
PITCH RANGE
10 DOWN
75 UP
101.6
4.00
MAX 21.15 [537.1]
CABLE
MANAGEMENT
COVER
5.250
16.00
73.3
MIN 2.88
MAX 5.635 [143.1]
3
K1S100/200
Installation Instructions
LEGEND
4
Tighten Fastener
Pencil Mark
Apretar elemento de fijación
Marcar con lápiz
Befestigungsteil festziehen
Stiftmarkierung
Apertar fixador
Marcar com lápis
Serrare il fissaggio
Segno a matita
Bevestiging vastdraaien
Potloodmerkteken
Serrez les fixations
Marquage au crayon
Loosen Fastener
Drill Hole
Aflojar elemento de fijación
Perforar
Befestigungsteil lösen
Bohrloch
Desapertar fixador
Fazer furo
Allentare il fissaggio
Praticare un foro
Bevestiging losdraaien
Gat boren
Desserrez les fixations
Percez un trou
Phillips Screwdriver
Adjust
Destornillador Phillips
Ajustar
Kreuzschlitzschraubendreher
Einstellen
Chave de fendas Phillips
Ajustar
Cacciavite a stella
Regolare
Kruiskopschroevendraaier
Afstellen
Tournevis à pointe cruciforme
Ajuster
Open-Ended Wrench
Remove
Llave de boca
Quitar
Gabelschlüssel
Entfernen
Chave de bocas
Remover
Chiave a punte aperte
Rimuovere
Steeksleutel
Verwijderen
Clé à fourche
Retirez
By Hand
Optional
A mano
Opcional
Von Hand
Optional
Com a mão
Opcional
A mano
Opzionale
Met de hand
Optie
À la main
En option
Hex-Head Wrench
Security Wrench
Llave de cabeza hexagonal
Llave de seguridad
Sechskantschlüssel
Sicherheitsschlüssel
Chave de cabeça sextavada
Chave de segurança
Chiave esagonale
Chiave di sicurezza
Zeskantsleutel
Veiligheidssleutel
Clé à tête hexagonale
Clé de sécurité
Installation Instructions
K1S100/200
TOOLS REQUIRED FOR INSTALLATION
#2
3/16" (included)
1/8" (included)
5/32" (included with K1S100 only, not required with K1S200)
PARTS
A (1)
[monitor arm]
(K1S100 shown)
B (4 or 8)*
M4x14mm
With K1S100 only
*8 screws and spacers
included with K1S200 mount
D (4 or 8)*
M10x5.3x10
C (4 or 8)*
M4x25mm
+
installation
instructions
+
F (1)
5/32"
E (1)
[OFBLU bracket]
or
With K1S200 only
+
installation
instructions
G (1)
[OFBU bracket]
H (1)
3/16"
J (1)
1/8"
5
K1S100/200
Installation Instructions
K1S200 to OFBU
K1S100 to OFBLU
2
2
(G)
(E)
side view
set screw
3
set screw
3
Figure 1
Assembly And Installation
2.
Carefully place display face down on protective surface.
Connecting K1S100-200 to Slat Wall
1.
Install OFBLU (E) or OFBU bracket (G) to slat wall following
corresponding installation instructions.
2.
Hang monitor arm (A) over OFBLU (E) or OFBU bracket (G).
(See Figure 1)
3.
Secure monitor arm (A) to OFBLU (E) or OFBU bracket (G)
by tightening 1/8" set screw (J). Ensure set screw engages
back side of wall bracket to properly secure mount. (See
Figure 1)
serious personal injury or damage to equipment! It is the
installer’s responsibility to make sure the combined weight of
all components located between the K1S100/200 Monitor
Arm up to (and including) the display does not exceed 25 lbs
(11.34 kg) per arm. Use with products heavier than the
maximum weight indicated may result in collapse of the
mount and its accessories causing possible injury.
3.
Display Installation
1.
WARNING: Exceeding the weight capacity can result in
Remove quick connect faceplate from mount by pressing
release tab and sliding faceplate off mount. (See Figure 2)
Connect faceplate to display
For flush mounting hole installation:
•
Using Phillips screwdriver, carefully install four
M4x14mm screws (B) through corresponding
holes on faceplate and into the mounting holes on
the display. (See Figure 3)
(for flush mounting holes)
1
quick connect
faceplate
1
release tab
Figure 2
6
3
Figure 3
(B) x 4
Installation Instructions
K1S100/200
For recessed mounting hole installation:
Adjustments
•
Head Tilt Adjustment
•
Place four spacers (D) on top of mounting holes
on back of display. (See Figure 4)
Using Phillips screwdriver, carefully install four
M4x25mm screws (C) through corresponding
holes on faceplate, spacers (D) and into the
mounting holes on the display. (See Figure 4)
1.
Adjust head tilt to desired tilt position. (See Figure 6)
2.
Use 3/16" hex key (H) to adjust head tilt tension screw to
change the adjustment tension. (See Figure 6)
Height Adjustment
(for recessed mounting holes)
1.
Adjust height to desired level. (See Figure 6)
2.
Use 1/8" hex key (J) to adjust height-adjustable tension
screw to change adjustment tension. (See Figure 6)
NOTE: Cable management cover must be opened in order to
quick connect
faceplate
3
(C) x 4
gain access to height-adjustable tension adjustment
screw.
NOTE: Turn clockwise to reduce tension for lighter displays
and counter-clockwise to increase tension for heavier
displays.
(D) x 4
Pivot Adjustment
1.
Adjust pivot position as desired. (See Figure 6)
2.
Use 3/16" hex key (H) to adjust pivot point tension screws
to change pivot adjustment tension. (See Figure 6)
(K1S100 shown)
head tilt tension
height-adjustable tension
(under cover)
Figure 4
4.
Position display with faceplate attached above mount. (See
Figure 5)
5.
Slide faceplate onto mounting head until release tab clicks
into place. (See Figure 5)
(K1S100 shown)
5
pivot point
tension
Figure 6
Figure 5
7
K1S100/200
Installation Instructions
Pivot Adjustment Range (K1S200 only)
Cable Management
1.
1.
Use screwdriver to unhinge tab on either end of cable
management cover on upper arm. (See Figure 9)
2.
Slide screwdriver along edge of cover until remaining tabs
are unhinged and cover is in the "open" position. (See
Figure 9) and (See Figure 10)
Adjust arm angles as desired within a 90 degree range from
the wall and a perpendicular centerline of mount. (See
Figure 7)
(top view)
edge of desk or wall face
cable management cover
1
2
90 degrees range
of motion per arm
perpendicular centerline
Figure 7
Portrait Adjustment
1.
Figure 9
The monitor may be adjusted 90 degrees in either direction
in order to provide a portrait view of the monitor. (See Figure
8)
(K1S100 shown)
(K1S100 shown)
3
cable (typical)
2
4
5
Figure 10
3.
Figure 8
WARNING: Only remove display from mount when the
display can be lifted up from the mount! DO NOT remove
display unless the display is in the upright position! See
Display Removal section for details.
8
Route cables through cable management channel. (See
Figure 10)
IMPORTANT ! : Be sure to leave enough slack in the
cables near display and arm joint to allow for full arm
articulation!
4.
Close cable management cover on upper monitor arm. (See
Figure 10)
5.
Route cables through cable management clip on lower arm.
(See Figure 10)
Installation Instructions
K1S100/200
Display Removal
WARNING: Only remove display from mount when the
display can be lifted up from the mount! DO NOT remove
display unless the display is in the upright position! (See
Figure 11)
1.
Make sure display is in the upright position.
2.
Remove quick connect faceplate from mount by pressing
release tab and sliding faceplate off mount. (See Figure 11)
release tab
2
Figure 11
9
K1S100/200
10
Installation Instructions
Installation Instructions
K1S100/200
11
K1S100/200
Installation Instructions
USA/International
Europe
Chief Manufacturing, a products division
of Milestone AV Technologies
8800-002085 Rev 01
2011 Milestone AV Technologies, a
Duchossois Group Company
www.chiefmfg.com
11/11
Asia Pacific
A
P
F
A
P
F
A
8401 Eagle Creek Parkway, Savage, MN 55378
800.582.6480 / 952.894.6280
877.894.6918 / 952.894.6918
Franklinstraat 14, 6003 DK Weert, Netherlands
+31 (0) 495 580 852
+31 (0) 495 580 845
Office No. 1 on 12/F, Shatin Galleria
18-24 Shan Mei Street
Fotan, Shatin, Hong Kong
P 852 2145 4099
F 852 2145 4477