Inte erve r Boa ard S S160 00JP

Inte
el® Se
erver Boa
ard S160
S 00JP
Tech
hnicall Prod
duct Sp
pecifiication
n
Intel order number G68
8018-005
Revis
sion 1.4
Marc
ch 2013
Enterp
prise Platforms and Se
ervices Divvision – Ma
arketing
Revision History
Intel® Server Board S1600JP TPS
Revision History
Date
ii
Revision
Number
Modifications
May 2012
0.5
Initial release.
June 2012
0.6


Updated Memory Support Guidelines.
Updated Processor Information.
July 2012
1.0
Updated All Block Diagrams.
October 2012
1.1
January 2013
1.2








Updated Fan Domain Mapping Table.
February 2013
1.3


March 2013
1.4

Update table-73 PCIe Slot 3 pin-out table
Updated Risers Information.
Updated BIOS Setup Interface.
Updated Connector and Header Location and Pin-out.
Updated Power Supply Specific Guidelines.
Updated BIOS Setup Interface.
Update the Memory Support Guidelines.
Updated power ON the server with ATX or EPS
power supply.
Update the size of heatsink mounting hole from
80X80 mm to 94X56 mm
Revision 1.4
Intel® Server Board S1600JP TPS
Disclaimers
Disclaimers
INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE,
EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS
GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR
SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR
IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR
WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR
INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.
A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly,
in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION
CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES,
SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH,
HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS'
FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL
INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR
NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF
THE INTEL PRODUCT OR ANY OF ITS PARTS.
Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not
rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves
these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from
future changes to them. The information here is subject to change without notice. Do not finalize a design with this
information.
The products described in this document may contain design defects or errors known as errata which may cause the
product to deviate from published specifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your
product order.
Copies of documents which have an order number and are referenced in this document, or other Intel literature, may
be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature.
Revision 1.4
iii
Table of Contents
Intel® Server Board S1600JP TPS
Table of Contents
1. Introduction .......................................................................................................................... 1 1.1 Section Outline .......................................................................................................... 1 1.2 Server Board Use Disclaimer .................................................................................... 2 2. Server Board Overview ........................................................................................................ 3 2.1 Server Board Connector and Component Layout .................................................... 5 2.1.1 Board Rear Connector Placement ............................................................................ 6 2.1.2 Server Board Mechanical Drawings ......................................................................... 7 3. Product Architecture Overview ........................................................................................... 8 3.1 High Level Product Features .................................................................................... 8 3.2 Processor Support................................................................................................... 10 3.2.1 Processor Socket Assembly ................................................................................... 10 3.3 Processor Function Overview ................................................................................. 11 3.3.1 Integrated Memory Controller (IMC) and Memory Subsystem .............................. 12 3.3.2 Processor Intergrated I/O Module (I/O) .................................................................. 19 3.4 Intel® C600-A PCH Functional Overview ................................................................ 23 3.4.1 PCI Express* ........................................................................................................... 24 3.4.2 Universal Serial Bus (USB) ..................................................................................... 24 3.4.3 Serial Attached SCSI (SAS) and Serial ATA (SATA) Controller ............................ 24 3.4.4 PCI Interface............................................................................................................ 26 3.4.5 Low Pin Count (LPC) Interface ............................................................................... 26 3.4.6 Digital Media Interface (DMI) .................................................................................. 26 3.4.7 Serials Peripheral Interface (SPI) ........................................................................... 26 3.4.8 Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller) ..... 26 3.4.9 Advanced Programmable Interrupt Controller (APIC) ............................................ 27 3.4.10 Real Time Clock (RTC) ........................................................................................... 27 3.4.11 GPIO ........................................................................................................................ 27 3.4.12 Enhanced Power Management............................................................................... 27 3.4.13 Fan Speed Control .................................................................................................. 27 3.4.14 Intel® Virtualization Technology for Direct I/O (Intel® VT-d) ................................... 27 3.4.15 KVM/Serial Over LAN (SOL) Function.................................................................... 28 3.4.16 IDE-R Function ........................................................................................................ 28 3.4.17 Manageability .......................................................................................................... 28 3.4.18 System Management Bus (SMBus* 2.0) ................................................................ 29 3.4.19 Network Interface Controller (NIC) ......................................................................... 29 3.5 Integrated Baseboard Management Controller Overview ...................................... 31 3.5.1 Super I/O Controller ................................................................................................ 33 3.5.2 Graphics Controller and Video Support .................................................................. 33 3.5.3 Remote KVM ........................................................................................................... 35 4. Platform Management Functional Overview .................................................................... 36 iv
Revision 1.4
Intel® Server Board S1600JP TPS
4.1 4.1.1 4.1.2 4.1.3 4.2 4.3 4.4 4.5 4.6 4.6.1 4.6.2 4.6.3 4.6.4 4.6.5 4.7 4.7.1 4.7.2 4.7.3 4.7.4 4.8 4.9 4.10 4.11 4.12 4.12.1 4.12.2 4.12.3 4.12.4 4.12.5 4.12.6 4.12.7 4.13 4.13.1 4.13.2 4.14 4.14.1 4.14.2 4.14.3 4.14.4 4.14.5 4.14.6 Revision 1.4
Table of Contents
Baseboard Management Controller (BMC) Firmware Feature Support ................ 36 IPMI 2.0 Features .................................................................................................... 36 Non-IPMI Features .................................................................................................. 37 New Manageability Features .................................................................................. 38 Advanced Configuration and Power Interface (ACPI) ............................................ 39 Platform Management SMBus* and I2C Implementation ....................................... 40 BMC Internal Timestamp Clock .............................................................................. 40 Sensor Monitoring ................................................................................................... 41 Messaging Interfaces .............................................................................................. 41 Channel Management ............................................................................................. 41 User Model .............................................................................................................. 42 Sessions .................................................................................................................. 43 BMC LAN Channels ................................................................................................ 44 IPv6 Support ............................................................................................................ 45 System Event Log (SEL) ......................................................................................... 46 Servicing Events ...................................................................................................... 47 SEL Entry Deletion .................................................................................................. 47 SEL Erasure ............................................................................................................ 47 SEL Extension Capabilities ..................................................................................... 47 Sensor Data Record (SDR) Repository .................................................................. 47 Field Replaceable Unit (FRU) Inventory Device ..................................................... 48 Diagnostics and Beep Code Generation ................................................................ 48 Diagnostics Interrupt (NMI) ..................................................................................... 49 BMC Basic and Advanced Management Features ................................................ 49 Enabling Advanced Manageability Features .......................................................... 50 Media Redirection ................................................................................................... 52 Embedded Web server ........................................................................................... 53 Data Center Management Interface (DCMI) ........................................................... 54 Lightweight Directory Authentication Protocol (LDAP) ........................................... 55 Platform/Chassis Management ............................................................................... 55 Thermal Control ....................................................................................................... 55 Intel® Intelligent Power Node Manager ................................................................... 57 Overview .................................................................................................................. 57 Features .................................................................................................................. 57 Management Engine (ME) ...................................................................................... 58 Overview .................................................................................................................. 58 BMC – Management Engine (ME) Distributed Model ............................................ 58 ME System Management Bus (SMBus*) Interface ................................................ 59 BMC - Management Engine Interaction.................................................................. 59 ME Power and Firmware Startup ............................................................................ 60 SmaRT/CLST .......................................................................................................... 60 v
Table of Contents
Intel® Server Board S1600JP TPS
4.15 Other Platform Management ................................................................................... 61 4.15.1 Wake On LAN (WOL) .............................................................................................. 61 4.15.2 PCI Express* Power management ......................................................................... 61 4.15.3 PMBus* .................................................................................................................... 61 5. BIOS Setup Interface .......................................................................................................... 62 5.1 HotKeys Supported During POST .......................................................................... 62 5.2 POST Logo/Diagnostic Screen ............................................................................... 62 5.3 BIOS Boot Pop-up Menu......................................................................................... 63 5.4 BIOS Setup Utility.................................................................................................... 63 5.4.1 BIOS Setup Operation ............................................................................................ 63 5.4.2 BIOS Setup Utility Screens ..................................................................................... 66 5.5 Loading BIOS Defaults .......................................................................................... 153 6. Configuration Jumpers .................................................................................................... 155 6.1.1 Force Integrated BMC Update (J2B4) .................................................................. 156 6.1.2 Force ME Update (J2B1) ....................................................................................... 157 6.1.3 Password Clear (J2B6) ......................................................................................... 157 6.1.4 BIOS Recovery Mode (J2B3) ................................................................................ 158 6.1.5 Reset BIOS Settings (J2B5) ................................................................................. 159 7. Connector/Header Locations and Pin-out ..................................................................... 161 7.1 Power Connectors ................................................................................................. 161 7.2 System Management Headers ............................................................................. 161 7.2.1 Intel® Remote Management Module 4 (Intel® RMM4 Lite) Connector .................. 161 7.2.2 IPMB Header ......................................................................................................... 162 7.2.3 Power Button ......................................................................................................... 162 7.2.4 Reset Button .......................................................................................................... 162 7.2.5 Chassis Identify Button ......................................................................................... 162 7.2.6 Power LED ............................................................................................................ 163 7.2.7 System Status LED ............................................................................................... 163 7.2.8 Chassis ID LED ..................................................................................................... 165 7.3 I/O Connectors ...................................................................................................... 165 7.3.1 PCI Express* Connectors ..................................................................................... 165 7.3.2 VGA Connector ..................................................................................................... 170 7.3.3 Internal Video for the front video ........................................................................... 170 7.3.4 NIC Connectors ..................................................................................................... 171 7.3.5 SATA Connectors.................................................................................................. 171 7.3.6 Mini SAS Connector .............................................................................................. 172 7.3.7 SATA SGPIO Connector ....................................................................................... 172 7.3.8 Hard Drive Activity (Input) LED Header ................................................................ 173 7.3.9 Storage Upgrade Key Connector .......................................................................... 173 7.3.10 Serial Port Connectors .......................................................................................... 173 7.3.11 USB Connectors .................................................................................................... 173 vi
Revision 1.4
Intel® Server Board S1600JP TPS
Table of Contents
7.3.12 TPM Connector ..................................................................................................... 174 7.3.13 SSI Front Panel Header ........................................................................................ 175 7.3.14 SMB PMBus* Connector ....................................................................................... 175 7.3.15 HSBP I2C Connector ............................................................................................. 175 7.4 Fan Headers .......................................................................................................... 176 7.5 Fan Domain Mapping ............................................................................................ 176 7.6 Chassis Intrusion ................................................................................................... 177 ®
8. Intel Light-Guided Diagnostics...................................................................................... 178 8.1 Front Panel Support .............................................................................................. 178 8.1.1 System ID LED ...................................................................................................... 178 8.1.2 System Status LED ............................................................................................... 178 8.1.3 Network Link/Activity LED ..................................................................................... 179 8.2 POST Code Diagnostic LEDs ............................................................................... 179 9. Environmental Limits Specifications ............................................................................. 180 9.1 Processor Thermal Design Power (TDP) Support ............................................... 181 10. Power Supply Specification Guidelines ......................................................................... 182 10.1 Power Supply DC Output Connector .................................................................... 182 10.2 Power Supply DC Output Specification ................................................................ 182 10.2.1 Output Power/Currents ......................................................................................... 182 10.2.2 Standby Output ..................................................................................................... 183 10.2.3 Voltage Regulation ................................................................................................ 183 10.2.4 Dynamic Loading................................................................................................... 183 10.2.5 Capacitive Loading ................................................................................................ 183 10.2.6 Grounding .............................................................................................................. 183 10.2.7 Closed loop stability .............................................................................................. 184 10.2.8 Residual Voltage Immunity in Standby mode ....................................................... 184 10.2.9 Common Mode Noise ........................................................................................... 184 10.2.10 Soft Starting ........................................................................................................... 184 10.2.11 Zero Load Stability Requirements ........................................................................ 184 10.2.12 Hot Swap Requirements ....................................................................................... 184 10.2.13 Forced Load Sharing ............................................................................................. 184 10.2.14 Ripple/Noise .......................................................................................................... 185 10.2.15 Timing Requirement .............................................................................................. 185 10.3 Power ON the Server Board with ATX or EPS Power Supply ............................. 186 Appendix A: Integration and Usage Tips .................................................................................. 190 Appendix B: Integrated BMC Sensor Tables ............................................................................. 191 Appendix C: BIOS Sensors and SEL Data................................................................................... 221 Appendix D: POST Code LED Decoder ....................................................................................... 228 Appendix E: Video POST Code Errors ........................................................................................ 234 Glossary .................................................................................................................................... 238 Reference Documents .............................................................................................................. 241
Revision 1.4
vii
List of Figures
Intel® Server Board S1600JP TPS
List of Figures
Figure 1. Intel® Server Board S1600JP (4NIC SKU) ..................................................................... 3 Figure 2. Intel® Server Board S1600JP Components .................................................................... 5 Figure 3. Rear Panel Connector Placement .................................................................................. 6 Figure 4. Baseboard and Mounting Holes ...................................................................................... 7 Figure 5. Intel® Server Board S1600JP Functional Block Diagram ............................................... 9 Figure 6. Processor Socket Assembly ......................................................................................... 10 Figure 7. Processor Socket ILM Variations .................................................................................. 11 Figure 8. Intel® Server Board S1600JP DIMM Slot Layout .......................................................... 17 Figure 9. PCIe Riser for Slot 1...................................................................................................... 20 Figure 10. PCIe Riser for Slot 2.................................................................................................... 21 Figure 11. Riser Carrier Board ..................................................................................................... 21 Figure 12. 1U PCIe Double Width PCI Express* Card Riser for Slot3 ........................................ 22 Figure 13. 1U PCIe FHFL Riser for Slot3 ..................................................................................... 22 Figure 14. Intel® C600-A PCH connection ................................................................................... 23 Figure 15. 1GbE NIC port LED ..................................................................................................... 30 Figure 16. Integrated BMC implementation overview (S1600JP2).............................................. 31 Figure 17. Integrated BMC Functional Block Diagram................................................................. 32 Figure 18. Management Engine Distribution Model ..................................................................... 59 Figure 19. Main Screen ................................................................................................................ 70 Figure 20. Advanced Screen ........................................................................................................ 73 Figure 21. Processor Configuration Screen ................................................................................. 76 Figure 22. Power and Performance Configuration Screen .......................................................... 82 Figure 23. Memory Configuration Screen .................................................................................... 86 Figure 24. Memory RAS and Performance Configuration Screen ............................................... 90 Figure 25. Mass Storage Controller Configuration Screen .......................................................... 92 Figure 26. PCI Configuration Screen ........................................................................................... 96 Figure 27. NIC Configuration Screen ......................................................................................... 100 Figure 28 PCIe Port Oprom Control Screen .............................................................................. 105 Figure 29. Serial Port Configuration Screen .............................................................................. 106 Figure 30. USB Configuration Screen ........................................................................................ 107 Figure 31. System Acoustic and Performance Configuration .................................................... 110 Figure 32. Security Screen ......................................................................................................... 113 Figure 33. Server Management Screen ..................................................................................... 118 Figure 34. Console Redirection Screen ..................................................................................... 124 Figure 35. System Information Screen ....................................................................................... 126 Figure 36. BMC LAN Configuration Screen ............................................................................... 129 Figure 37. Boot Options Screen ................................................................................................. 137 Figure 38. CDROM Order Screen .............................................................................................. 141 Figure 39. Hard Disk Order Screen ............................................................................................ 142 viii
Revision 1.4
Intel® Server Board S1600JP TPS
List of Figures
Figure 40. Floppy Order Screen ................................................................................................. 143 Figure 41. Network Device Order Screen .................................................................................. 144 Figure 42. BEV Device Order Screen ........................................................................................ 145 Figure 43. Add EFI Boot Option Screen ..................................................................................... 146 Figure 44. Delete EFI Boot Option Screen ................................................................................. 147 Figure 45. Boot Manager Screen ............................................................................................... 148 Figure 46. Error Manager Screen ............................................................................................... 149 Figure 47. Save & Exit Screen ................................................................................................... 150 Figure 48. Jumper Blocks (J2B1, J2B3, J2B5, J2B6, J2B4, and J2B2) .................................... 155 Figure 49. System Status LED (A), 5V StandBy LED (B), and ID LED (C) ............................... 163 Figure 50. Rear Panel Diagnostic LEDs (Block A)..................................................................... 179 Figure 51. 750W Turn On/Off Timing (Power Supply Signals) .................................................. 186 Figure 52. Main Power Connector 1, 2 and PMbus Connector ................................................. 186 Figure 53. 2X12pin to 2X5 pin Power Adapter Cable ................................................................ 187 Figure 54. 2X12 Power Connector Pin Number ......................................................................... 187 Figure 55. 2X5 Pin Number ........................................................................................................ 188 Figure 56. Front Panel Pin 11 and 13 ........................................................................................ 189 Figure 57. Diagnostic LED Placement Diagram ........................................................................ 228
Revision 1.4
ix
List of Tables
Intel® Server Board S1600JP TPS
List of Tables
Table 1. Intel® Server Board S1600JP Feature Set ....................................................................... 3 Table 2. Intel® Server Board S1600JP Features............................................................................ 8 Table 3. Intel® Xeon® processor E5-2600 product family UDIMM Support Guidelines ............... 13 Table 4. Intel® Xeon® processor E5-2600 product family RDIMM Support Guidelines ............... 14 Table 5. Intel® Xeon® processor E5-2600 product family LRDIMM Support Guidelines ............. 14 Table 6 Intel® Xeon® processor E5-1600 product family UDIMM Support Guidelines ................ 15 Table 7. Intel® Xeon® processor E5-1600 product family RDIMM Support Guidelines ............... 16 Table 8. Intel® Server Board S1600JP DIMM Nomenclature ...................................................... 17 Table 9. Power budget for riser slot ............................................................................................. 20 Table 10. Intel® Server Board S1600JP SATA/SAS port ............................................................. 25 Table 11. Intel® RAID C600 Storage Upgrade Key Options for S1600JP ................................... 25 Table 12. NIC Status LED ............................................................................................................ 30 Table 13. Video Modes ................................................................................................................. 34 Table 14. Video mode ................................................................................................................... 34 Table 15. ACPI Power States ....................................................................................................... 39 Table 16. Standard Channel Assignments ................................................................................... 41 Table 17. Default User Values ...................................................................................................... 42 Table 18. Channel/Media-specific minimum number of sessions ............................................... 43 Table 19. BMC Beep Codes ......................................................................................................... 48 Table 20. NMI Signal Generation and Event Logging.................................................................. 49 Table 21. Basic and Advanced Management Features ............................................................... 49 Table 22. Management features and Benefits ............................................................................. 50 Table 23. Fab Profile Mapping ..................................................................................................... 56 Table 24. POST HotKeys Recognized ......................................................................................... 62 Table 25. BIOS Setup Page Layout ............................................................................................. 64 Table 26. BIOS Setup: Keyboard Command Bar ........................................................................ 65 Table 27. Screen Map .................................................................................................................. 68 Table 28. Setup Utility – Main Screen Fields ............................................................................... 71 Table 29. Setup Utility – Advanced Screen Display Fields .......................................................... 73 Table 30. Setup Utility – Processor Configuration Screen Fields ................................................ 76 Table 31. Setup Utility – Power and Performance Configuration Screen Fields ......................... 82 Table 32. Power/Performance Profiles......................................................................................... 83 Table 33. Setup Utility – Memory Configuration Screen Fields ................................................... 86 Table 34. Setup Utility – Memory RAS and Performance Configuration Fields .......................... 90 Table 35. Mass Storage Controller Configuration Fields ............................................................. 93 Table 36. Setup Utility – PCI Configuration Screen Fields .......................................................... 97 Table 37. Setup Utility – NIC Configuration Screen Fields ........................................................ 100 Table 38 Setup Utility – PCIe Port Oprom Control Screen Fields ............................................. 105 Table 39. Setup Utility – Serial Ports Configuration Screen Fields ........................................... 106 x
Revision 1.4
Intel® Server Board S1600JP TPS
List of Tables
Table 40. Setup Utility – USB Controller Configuration Screen Fields ...................................... 108 Table 41. Setup Utility – System Acoustic and Performance Configuration Screen Fields ...... 111 Table 42. Setup Utility – Security Configuration Screen Fields ................................................. 113 Table 43. Setup Utility – Server Management Configuration Screen Fields ............................. 118 Table 44. Setup Utility – Console Redirection Configuration Fields .......................................... 124 Table 45. Setup Utility – Server Management System Information Fields ................................ 126 Table 46. Setup Utility – BMC configuration Screen Fields ....................................................... 129 Table 47. Setup Utility – Boot Options Screen Fields ................................................................ 138 Table 48. Setup Utility – CDROM Order Fields.......................................................................... 142 Table 49. Setup Utility – Hard Disk Order Fields ....................................................................... 143 Table 50. Setup Utility – Floppy Order Fields ............................................................................ 144 Table 51. Setup Utility – Network Device Order Fields .............................................................. 145 Table 52. Setup Utility – BEV Device Order Fields .................................................................... 145 Table 53. Setup Utility – Add Boot Option Fields ....................................................................... 146 Table 54. Setup Utility – Delete EFI Boot Option Fields ............................................................ 147 Table 55. Setup Utility – Boot Manager Screen Fields .............................................................. 148 Table 56. Setup Utility – Error Manager Screen Fields ............................................................. 149 Table 57. Setup Utility – Exit Screen Fields ............................................................................... 151 Table 58. Server Board Jumpers (J6B1, J1E2, J1E3, J1E1, J1D5) .......................................... 155 Table 59. Force Integrated BMC Update Jumper ...................................................................... 156 Table 60. Force ME Update Jumper .......................................................................................... 157 Table 61. Password Clear Jumper ............................................................................................. 158 Table 62. BIOS Recovery Mode Jumper.................................................................................... 158 Table 63. Reset BIOS Jumper .................................................................................................... 159 Table 64. Main Power Supply Connector 10-pin 2x5 Connector Pin-Out (J4K1) ..................... 161 Table 65. Main Power Supply Connector 8-pin 2x4 Connector Pin-Out (J6K1) ....................... 161 Table 66. Intel® RMM4 Lite Connector Pin-out (J6A2) .............................................................. 161 Table 67. IPMB Header Pin-Out (J6A4) ..................................................................................... 162 Table 68. Power LED Indicator States ....................................................................................... 163 Table 69. System Status LED .................................................................................................... 164 Table 70. Chassis ID LED Indicator States ................................................................................ 165 Table 71. PCI Express* x16 Riser Slot 1 Connector (J6B1) ...................................................... 165 Table 72. PCI Express* x8 Riser Slot 2 Connector (J1A2) ........................................................ 167 Table 73. PCI Express* x16 Riser Slot 3 Connector (J1B1 and J1D1) ..................................... 168 Table 74. VGA External Video Connector Pin-Out (J5A1) ........................................................ 170 Table 75. Internal Video Connector Pin-Out (J6A1) .................................................................. 170 Table 76. RJ-45 10/100/1000 NIC Connector Pin-out (JA4A1 and JA3A1) .............................. 171 Table 77. SATA Connectors Pin-Out (J6E1, J2E2, J2E1, J2E3, J1E3, and J2D3) .................. 171 Table 78. Mini SAS Connector Pin-Out (J2D2) .......................................................................... 172 Table 79. SATA SGPIO Connector Pin-Out (J1E1) ................................................................... 172 Table 80. SATA HDD Activity (Input) LED Header (J6F1) ......................................................... 173 Revision 1.4
xi
List of Tables
Intel® Server Board S1600JP TPS
Table 81. Storage Upgrade Key Connector Pin-Out (J3E1) ...................................................... 173 Table 82. Internal Serial Port Connecter Pin-Out (J5A2) ........................................................... 173 Table 83. External USB port Connector Pin-Out (J1A1 and J2A1) ........................................... 173 Table 84. Type A USB connector Pin-Out (J1D2) ..................................................................... 174 Table 85. Internal USB Connector Pin-Out (J6E2 and J2D1).................................................... 174 Table 86. TPM Connector Pin-Out (J6B2) ................................................................................. 174 Table 87. SSI Front Panel Header Pin-Out (J6H1) .................................................................... 175 Table 88. PMBus* Connector Pin-Out (J6H2)............................................................................ 175 Table 89. HSBP I2C Connector Pin-Out (J1E2) ......................................................................... 175 Table 90. Baseboard Fan Connector Pin-Out (J1K1, J1K2, J3K1, J4K2, J6K2, and J6K3) ..... 176 Table 91. S1600JP Fan Connctor and Fan Domain Mapping Table ......................................... 176 Table 92. Chassis Intrusion Header (J6A3) ............................................................................... 177 Table 93. Network link/activity LED ............................................................................................ 179 Table 94. Server Board Design Specifications........................................................................... 180 Table 95. Main Power Supply Connector 1 (10-pin 2x5) Connector Pin-Out ............................ 182 Table 96. Main Power Supply Connector 2 (8-pin 2x4) Connector Pin-Out .............................. 182 Table 97. 750W Minimum Load Ratings .................................................................................... 182 Table 98. 750W Voltage Regulation Limits ................................................................................ 183 Table 99. 750W Transient Load Requirements ......................................................................... 183 Table 100. 750W Capacitive Loading Conditions ...................................................................... 183 Table 101. 750W Ripples and Noise .......................................................................................... 185 Table 102. 750W Timing Requirements ..................................................................................... 185 Table 103. 2X12 Pin Power Connector Pin-Out ....................................................................... 188 Table 104. 2X5 Pin Connector Pin-Out ...................................................................................... 188 Table 105. 2X12 Pin to 2X5 Pin Connector Mapping Table ...................................................... 189 Table 106. BMC Core Sensors................................................................................................... 193 Table 107. BIOS Sensor and SEL Data ..................................................................................... 221 Table 108. POST Progress Code LED Example ....................................................................... 228 Table 109. Diagnostic LED POST Code Decoder ..................................................................... 229 Table 110. POST Error Messages and Handling ....................................................................... 234 Table 111. Glossary .................................................................................................................... 238 xii
Revision 1.4
<This page is intentionally left blank.>
Revision 1.4
xiii
Intel® Server Board S1600JP TPS
1.
Introduction
Introduction
The Intel® Server Board S1600JP is a half width, single socket server board using the Intel®
Xeon® Processor E5-2600 series or Intel® Xeon® Processor E5-1600 series processor, in
combination with Intel® C600 chipset to provide a balance feature set between technology
leadership and cost.
This Technical Product Specification (TPS) provides board-specific information detailing the
features, functionality, and high-level architecture of the Intel® Server Boards S1600JP.
For design-level information of specific components or subsystems relevant to the server boards
described in this document, additional documents can be obtained through Intel®. The reference
documents lists documents used as reference to compile much of the data provided here. Some
of the listed documents are not publically available and must be ordered through your local
Intel® representative.
1.1
Section Outline
This document is divided into the following chapters:

















Revision 1.4
Chapter 1 – Introduction
Chapter 2 – Server Board Overview
Chapter 3 – Product Architecture Overview
Chapter 4 – Platform Management Functional Overview
Chapter 5 – BIOS Setup Interface
Chapter 6 – Configuration Jumpers
Chapter 7 – Connector and Header Location and Pin-out
Chapter 8 – Intel® Light-Guided Diagnostics
Chapter 9 – Environmental Limits Specifications
Chapter 10 – Power Supply Specification Guidelines
Appendix A – Integration and Usage Tips
Appendix B – Integrated BMC Sensor Tables
Appendix C – BIOS Sensors and SEL Data
Appendix D – POST Code LED Decoder
Appendix E – Video POST Code Errors
Glossary
Reference Documents
1
Introduction
1.2
Intel® Server Board S1600JP TPS
Server Board Use Disclaimer
Intel Corporation server boards contain a number of high-density VLSI and power delivery
components that need adequate airflow to cool. Intel® ensures through its own chassis
development and testing, that when Intel® server building blocks are used together, the fully
integrated system will meet the intended thermal requirements of these components. It is the
responsibility of the system integrator who chooses not to use Intel® developed server building
blocks to consult vendor datasheets and operating parameters to determine the amount of air
flow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
2
Revision 1.4
Intel® Server Board S1600JP TPS
2.
Server Board Overview
Server Board Overview
The Intel® Server Board S1600JP is a monolithic Printed Circuit Board (PCB) with features
designed to support the high performance and high density computing markets. This server
board is designed to support the Intel® Xeon® processor E5-2600 or Intel® Xeon® processor E51600 product family. Previous generation Intel® Xeon® processors are not supported. Many of
the features and functions of the server board family are common. A board will be identified by
name when a described feature or function is unique to it.
Figure 1. Intel® Server Board S1600JP (4NIC SKU)
There are two board SKUs based on different hardware configurations:
 S1600JP4: Base SKU with Quad NIC
 S1600JP2: Base SKU with Dual NIC
The following table provides a high-level product feature list:
Table 1. Intel® Server Board S1600JP Feature Set
Feature
Processors
Revision 1.4
Description
Support for one Intel® Xeon® Processor E5-2600 series or one Intel® Xeon®
Processor E5-1600 series
 LGA 2011 Socket R
®
®
 Thermal Design Power (TDP) up to 135 Watts for Intel Xeon Process E5-2600
®
®
series or up to 130 Watts for Intel Xeon Processor E5-1600 series
3
Server Board Overview
Intel® Server Board S1600JP TPS
Feature
Memory
 Eight DIMM slots, four memory channels, two DIMM slots per channel
 Unbuffered DDRIII (UDIMM), Registered DDRIII (RDIMM) and Load Reduced
DDRIII (LRDIMM)
 Memory DDRIII data transfer rate of 800/1066/1333/1600MT/s
 DDRIII standard I/O voltage of 1.5V (all speed) and DDRIII Low Voltage of 1.35V
(1333MT/s or below)
Chipset
Intel C600-A Platform Controller Hub (PCH) with support for optional Storage
Upgrade Key.
 DB-15 Video connectors
 Four RJ-45 Network Interface for 10/100/1000 LAN (SKU: S1600JP4)
 Two RJ-45 Network Interface for 10/100/1000LAN (SKU: S1600JP2)
 Two USB 2.0 connectors
 One Type A USB connector
 Two 2 x 5 USB connectors
 One 2 x 5 serial port connector
 One internal video connector for the front video
 Six SATA connectors
 One mini SAS connector
 One 2 x 5 connector for board main power 1
 One 2 x 1 connector for board main power 2
 Six system fan connectors
Three PCIe Gen III riser slots
 Riser slot 1 and 3 support PCIe Gen III x16 Riser
®
 Riser slot 2 supports PCIe Gen III x8 Riser (Intel rIOM)
External I/O Connections
Internal I/O
connectors/headers
Power Connections
System Fan Support
Add-in Riser Support
Video
Hard Drive Support
RAID Support
Server Management
Description
®












Integrated 2D Video Graphics controller
128 MB DDRIII Memory
Two 6Gbps SATA ports
Four SATA ports at 3Gbps
One mini-SAS port
®
Intel RSTe SW RAID 0/1/10/5 for SATA mode
ESRTII SW RAID 0/1/10/5
Onboard Emulex* LLC Pilot III* Controller
Support for Intel® Remote Management Module 4 Lite solutions
®
Intel Light-Guided Diagnostics on field replaceable units
®
Support for Intel System Management Software
®
Support for Intel Intelligent Power Node Manager (Need PMBus*-compliant
power supply)
4
Revision 1.4
Intel® Server Board S1600JP TPS
2.1
Server Board Overview
Server Board Connector and Component Layout
The following illustration provides a general overview of the server board, identifying key feature
and component locations. The majority of the items identified are common in the Intel® Server
Board S1600JP family. The accompanying table will identify variations when present.
A
6 system fans
K
Storage upgrade
key
U
5V standby LED
AE
Internal USB
B
8 DIMM sockets
L
Riser slot 2
V
ID LED
AF
HDD LED Header
C
CPU socket
M
Riser Slot 3A
W
Internal Video
connector
AG
Two 6Gbps SATA
ports
D
Four 3Gbps SATA
ports
N
Two external rear
USBs
X
IPMB
AH
HDD LED
E
HSBP I2C
O
Diagnostic LED
Y
Chassis intrusion
AI
Battery
F
SGPIO
P
4 NIC 1Gbe ports
Z
TPM connector
AJ
Front panel
connector
G
TypeA USB
Q
System status
LED
AA
Riser slot 1
AK
PMBus*
H
Riser Slot 3B
R
Internal Serial port
AB
CPLD/JTAG
AL
5x2 Main power 1
I
Internal USB
S
Video port
AC
PECI
AM
4x2 Main power 2
J
Mini SAS port
T
RMM4 lite
AD
LCP
Figure 2. Intel® Server Board S1600JP Components
Revision 1.4
5
Server Board Overview
2.1.1
Intel® Server Board S1600JP TPS
Board Rear Connector Placement
®
The Intel Server Board S1600JP has the following board rear connector placement:
Description
A
B
C
D
E
ID LED
5V standby LED
DB15 Video out
Two NIC ports (RJ45)
System status LED
Description
F
G
H
I
Two NIC ports (RJ45)
USB connector
Diagnostic LED
USB connector
Figure 3. Rear Panel Connector Placement
6
Revision 1.4
Intel® Server Board S1600JP TPS
2.1.2
Server Board Overview
Server Board Mechanical Drawings
The following figures are mechanical drawings for the Intel® Server Board S1600JP:
Figure 4. Baseboard and Mounting Holes
Revision 1.4
7
Product Architecture Overview
3.
Intel® Server Board S1600JP TPS
Product Architecture Overview
The Intel® Server Board S1600JP is a purpose build, rack-optimized server board used in a
high-density rack system. It is designed around the integrated features and functions of the
Intel® Xeon® processor E5-2600 or Intel® Xeon® processor E5-1600 product family, the Intel®
C600-A chipset, and other supporting components including the Emulex* PILOT III Integrated
BMC, the Intel® I350-AM4 Quad 1GbE network controller.
3.1
High Level Product Features
Table 2. Intel® Server Board S1600JP Features
Board
Form Factor
Half Width form-factor (13.8” x 6.8”)
CPU Socket
Socket R, LGA2011
Chipset
Intel C600 Chipset PCH – A SKU
Memory








Slots
Ethernet
SATA
SAS
8
S1600JP
®
Support for 8 DDR-III LRDIMMs
Support for 8 DDR-III RDIMMs
Support for 8 DDR-III UDIMMs
2 PCIe GenIII x16 connector
1 PCIe GenIII x8 connector for rIOM
®
Dual Intel I350-AM4 GbE (S1600JP2)
®
Quad Intel I350-AM4 GbE(S1600JP4)
Six SATA ports from AHCI including 2x
SATA 6Gb/s and 4x SATA 3Gb/s
One Mini SAS port
®
®
SW RAID
Intel ESRT2 SAS/SATA RAID 0,1,5,10 or Intel
RSTe SATA RAID 0,1,5, and 10
Processor Support

135W maximum for Intel Xeon Processor
E5-2600 product family

130W maximum for Intel Xeon Processor
E5-1600 product family
®
®
®
®
Video
Integrated on Emulex* PILOT III BMC:
SMS

Matrox* G200 Core

16MByte of video memory assigned
Emulex* PILOT III BMC w/IPMI 2.0 support
Chassis
1U Rack Chassis
Power Supply
12V and 5VS/B PMBus*
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
Figure 5. Intel® Server Board S1600JP Functional Block Diagram
Revision 1.4
9
Product Architecture Overview
3.2
Intel® Server Board S1600JP TPS
Processor Support
The server board includes one Socket-R (LGA2011) processor socket and can support the
Intel® Xeon® processor E5-2600 or Intel® Xeon® processor E5-1600 product family, with a
Thermal Design Power (TDP) of up to 135W for Intel® Xeon® processor E5-2600 product family
or up to 130W for Intel® Xeon® processor E5-1600 product family.
The Intel® Xeon™ E5-2600 processor family is composed of 6/8 cores respectively, and the
Intel® Xeon™ E5-1600 processor family is composed of 4/6 cores respectively. The
microprocessors include an integrated DDRIII memory controller (IMC) with four memory
channels which can support up to three ECC Registered DIMMs or three Un-buffered ECC
DIMMs per memory channel, an integrated I/O controller with 40 PCI Express* GenIII lanes
controlled by ten PCI Express* Master Controllers.
Previous generation Intel® Xeon® processors are not supported on the Intel® server boards
described in this document.
Visit the Intel® website for a complete list of supported processors.
3.2.1
Processor Socket Assembly
The processor socket of the server board is pre-assembled with an Independent Latching
Mechanism (ILM) and Back Plate that allow for secure placement of the processor and
processor heat to the server board.
The following illustration identifies each sub-assembly component:
Figure 6. Processor Socket Assembly
10
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
Figure 7. Processor Socket ILM Variations
The square ILM has an 94x56mm heatsink mounting hole pattern and is used on the Intel®
Server Board S1600JP.
3.3
Processor Function Overview
With the release of Intel® Xeon® processor E5-2600 and Intel® Xeon® processor E5-1600
product family, several key system components, including the CPU, Integrated Memory
Controller (IMC), and Integrated IO Module (IIO), have been combined into a single processor
package and feature per socket; two Intel® QuickPath Interconnect point-to-point links capable
of up to 8.0 GT/s, up to 40 lanes of GenIII PCI Express* links capable of 8.0 GT/s, and 4 lanes
of DMI2/PCI Express* Gen 2 interface with a peak transfer rate of 5.0 GT/s. The processor
supports up to 46 bits of physical address space and 48-bit of virtual address space.
The following sections provide an overview of the key processor features and functions that help
to define the performance and architecture of the server board. For more comprehensive
processor specific information, refer to the Intel® Xeon® processor E5-2600 or Intel® Xeon®
processor E5-1600 product family documents
Processor Feature Details:




Up to eight execution cores for Intel® Xeon® processor E5-2600 product family or up to
six execution cores for Intel® Xeon® processor E5-1600 product family.
Each core supports two threads (Intel® Hyper-Threading Technology), up to 16 threads
per socket for Intel® Xeon® processor E5-2600 product family or up to 12 threads per
socket for Intel® Xeon® processor E5-1600 product family.
46-bit physical addressing and 48-bit virtual addressing.
1 GB large page support for server applications.
Revision 1.4
11
Product Architecture Overview



Intel® Server Board S1600JP TPS
A 32-KB instruction and 32-KB data first-level cache (L1) for each core.
A 256-KB shared instruction/data mid-level (L2) cache for each core.
Up to 20 MB last level cache (LLC): up to 2.5 MB per core instruction/data last level
cache (LLC), shared among all cores.
Supported Technologies:













3.3.1














12
Intel® Virtualization Technology (Intel® VT)
Intel® Virtualization Technology for Directed I/O (Intel® VT-d)
Intel® Virtualization Technology Intel® Xeon® E5-2600 and Intel® Xeon® E5-1600
Processor Extensions
Intel® Trusted Execution Technology (Intel® TXT)
Intel® 64 Architecture
Intel® Streaming SIMD Extensions 4.1 (Intel® SSE4.1)
Intel® Streaming SIMD Extensions 4.2 (Intel® SSE4.2)
Intel® Advanced Vector Extensions (Intel® AVX)
Intel® Hyper-Threading Technology
Execute Disable Bit
Intel® Turbo Boost Technology
Intel® Intelligent Power Technology
Enhanced Intel® SpeedStep Technology
Integrated Memory Controller (IMC) and Memory Subsystem
Unbuffered DDRIII and registered DDRIII DIMMs.
LR DIMM (Load Reduced DIMM) for buffered memory solutions demanding higher
capacity memory subsystems.
Independent channel mode or lockstep mode.
Data burst length of eight cycles for all memory organization modes.
Memory DDRIII data transfer rates of 800, 1066, 1333, and 1600 MT/s.
64-bit wide channels plus 8-bits of ECC support for each channel.
DDRIII standard I/O Voltage of 1.5V for all speed.
DDRIII Low Voltage of 1.35V for 1333MT/s or below.
1-Gb, 2-Gb, and 4-Gb DDRIII DRAM technologies supported for these devices:
o UDIMM DDRIII – SR x8 and x16 data widths, DR – x8 data width.
o RDIMM DDRIII – SR, DR, and QR – x4 and x8 data widths.
o LRDIMM DDRIII – QR – x4 and x8 data widths with direct map or with
rank multiplication.
Up to 8 ranks supported per memory channel, 1, 2, or 4 ranks per DIMM.
Open with adaptive idle page close timer or closed page policy.
Per channel memory test and initialization engine can initialize DRAM to all logical zeros
with valid ECC (with or without data scrambler) or a predefined test pattern.
Isochronous access support for Quality of Service (QoS).
Minimum memory configuration: Independent channel support with one DIMM populated
Revision 1.4
Intel® Server Board S1600JP TPS




Product Architecture Overview
Integrated dual SMBus* master controllers.
Command launch modes of 1n/2n.
RAS Support:
o Rank Level Sparing and Device Tagging.
o Demand and Patrol Scrubbing.
o DRAM Single Device Data Correction (SDDC) for any single x4 or x8 DRAM
device. Independent channel mode supports x4 SDDC. x8 SDDC requires
lockstep mode.
o Lockstep mode where channels 0 and 1 and channels 2 and 3 are operated in
lockstep mode.
o Data scrambling with address to ease detection of write errors to an
incorrect address.
o Error reporting through Machine Check Architecture.
o Read Retry during CRC error handling checks by iMC.
o Channel mirroring within a socket.
o Error Containment Recovery.
o Improved Thermal Throttling with dynamic Closed Loop Thermal Throttling
(CLTT).
Memory thermal monitoring support for DIMM temperature.
3.3.1.1
Supported Memory
Table 3. Intel® Xeon® processor E5-2600 product family UDIMM Support Guidelines
Speed (MT/s) and Voltage Validated by Slot Per Channel (SPC) and
DIMM Per Channel (DPC)2
Ranks Per DIMM
and Data Width
Memory Capacity Per
DIMM1
2 Slots Per Channel
1DPC
1.35V
2DPC
1.5V
.35V
1.5V
SRx8
Non-ECC
1GB
2GB
4GB
n/a
1066, 1333 n/a
1066, 1333
DRx8
Non-ECC
2GB
4GB
8GB
n/a
1066, 1333 n/a
1066, 1333
SRx16
Non-ECC
512MB
1GB
2GB
n/a
1066, 1333 n/a
1066, 1333
SRx8
ECC
1GB
2GB
4GB
1066, 1333,
1066, 1333 1066
3
1600
1066, 1333
2GB
4GB
8GB
1066, 1333,
1066, 1333 1066
3
1600
1066, 1333
DRx8
ECC
Revision 1.4
13
Product Architecture Overview
Intel® Server Board S1600JP TPS
Notes:
®
1.
2.
3.
Supported DRAM Densities are 1Gb, 2Gb, and 4Gb. Only 2Gb and 4Gb are validated by Intel .
Command Address Timing is 1N for 1DPC and 2N for 2DPC.
These speed options are only available when “Memory SPD Override” option in BIOS is enabled.
Table 4. Intel® Xeon® processor E5-2600 product family RDIMM Support Guidelines
Ranks
Per
DIMM
and
Data
Width
Speed (MT/s) and Voltage Validated by Slot Per Channel (SPC) and
DIMM Per Channel (DPC)2,3
Memory Capacity Per DIMM1
2 Slots Per Channel
1DPC
1.35V
2DPC
1.5V
1.35V
1.5V
SRx8
1GB
2GB
4GB
1066, 1333,
4
1600
1066, 1333,
1600
1066, 1333,
4
1600
1066, 1333,
1600
DRx8
2GB
4GB
8GB
1066, 1333
4
1600
1066, 1333,
1600
1066, 1333,
4
1600
1066, 1333,
1600
SRx4
2GB
4GB
8GB
1066, 1333
4
1600
1066, 1333,
1600
1066, 1333,
4
1600
1066, 1333,
1600
DRx4
4GB
8GB
16GB
1066, 1333
4
1600
1066, 1333,
1600
1066, 1333,
4
1600
1066, 1333,
1600
QRx4
8GB
16GB
32GB
800
1066
800
800
QRx8
4GB
8GB
16GB
800
1066
800
800
Notes:
1.
2.
3.
4.
Supported DRAM Densities are 1Gb, 2Gb, and 4Gb. Only 2Gb and 4Gb are validated by Intel®.
Command Address Timing is 1N.
QR RDIMM are supported but only validated by Intel® in a homogenous environment. The coverage will have limited
system level testing, no signal integrity testing, and no interoperability testing. The passing QR RDIMMs will be web
posted.
These speed options are only available when “Memory SPD Override” option in BIOS is enabled.
Table 5. Intel® Xeon® processor E5-2600 product family LRDIMM Support Guidelines
Speed (MT/s) and Voltage Validated by Slot Per Channel (SPC)
and DIMM Per Channel (DPC)3, 4
Ranks Per DIMM
and Data Width1
Memory Capacity Per DIMM2
2 Slots Per Channel
1DPC and 2DPC
1.35V
14
1.5V
Revision 1.4
Intel® Server Board S1600JP TPS
QRx4 (DDP)
5
QRx8 (DDP)
5
Product Architecture Overview
16GB
32GB
1066
1066, 1333
8GB
16GB
1066
1066, 1333
Notes:
1.
2.
3.
4.
5.
Physical Rank is used to calculate DIMM Capacity.
Supported and validated DRAM densities are 2Gb and 4Gb.
Command Address Timing is 1N.
The speeds are estimated targets and will be verified through simulation.
DDP - Dual Die Package DRAM stacking. P – Planer monolithic DRAM Die.
Table 6 Intel® Xeon® processor E5-1600 product family UDIMM Support Guidelines
Ranks Per DIMM
and Data Width
Speed (MT/s) and Voltage Validated by Slot Per Channel (SPC) and
DIMM Per Channel (DPC)2
Memory Capacity Per DIMM1
2 Slots Per Channel (1.5V)
1DPC
2DPC
SRx8
Non-ECC
1GB
2GB
4GB
1066, 1333
1066, 1333
DRx8
Non-ECC
2GB
4GB
8GB
1066,1333
1066,1333
SRx16
Non-ECC
512MB
1GB
2GB
1066,1333
1066,1333
SRx8
ECC
1GB
2GB
4GB
1066, 1333
1066, 1333
2GB
4GB
8GB
1066, 1333
1066, 1333
DRx8
ECC
Notes:
1.
2.
®
Supported DRAM Densities are 1Gb, 2Gb, and 4Gb. Only 2Gb and 4Gb are validated by Intel .
Command Address Timing is 1N for 1DPC and 2N for 2DPC.
Revision 1.4
15
Product Architecture Overview
Intel® Server Board S1600JP TPS
Table 7. Intel® Xeon® processor E5-1600 product family RDIMM Support Guidelines
Speed (MT/s) and Voltage Validated by Slot Per
Channel (SPC) and DIMM Per Channel (DPC)2, 3
Ranks Per DIMM and Data Width
Memory Capacity Per DIMM1
2 Slots Per Channel (1.5V)
1DPC
2DPC
SRx8
1GB
2GB
4GB
1066, 1333, 1600
1066, 1333, 1600
DRx8
2GB
4GB
8GB
1066, 1333, 1600
1066, 1333, 1600
SRx4
2GB
4GB
8GB
1066, 1333, 1600
1066, 1333, 1600
DRx4
4GB
8GB
16GB
1066, 1333, 1600
1066, 1333, 1600
QRx4
8GB
16GB
32GB
1066
800
QRx8
4GB
8GB
16GB
1066
800
Notes:
1.
2.
3.
3.3.1.2
®
Supported DRAM densities are 1Gb, 2Gb, and 4Gb. Only 2Gb and 4Gb are validated by Intel .
Command Address Timing is 1N.
®
QR RDIMM are supported but only validated by Intel in a homogenous environment. The coverage will
have limited system level testing, no signal integrity testing, and no interoperability testing. The passing
QR RDIMMs will be web posted.
Memory population rules
Note: All memory on Intel® Server Board S1600JP is expected to match in all respects,
including the memory vendor. S1600JP does not support any mix of memory parts, whether or
not a mixed configuration may be able to operate successfully in a particular instance.
The processor provides four banks of memory, each capable of supporting up to four DIMMs.

DIMMs are organized into physical slots on DDRIII memory channels that belong to
processor sockets.

The memory channels from the processor socket are identified as Channel A, B, C, and
D. The silk screened DIMM slot identifiers on the board provide information about the
channel. For example, DIMM_A1 is the first slot on Channel A; DIMM_A2 is the second
DIMM socket on Channel A.
On the Intel® Server Board S1600JP, a total of eight DIMM slots is provided. The nomenclature
for DIMM sockets is detailed in the following table:
16
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
Table 8. Intel® Server Board S1600JP DIMM Nomenclature
Processor Socket
(0)
Channel A
A1
A2
(1)
Channel B
B1
B2
(2)
Channel C
C1
C2
(3)
Channel D
D1
D2
Figure 8. Intel® Server Board S1600JP DIMM Slot Layout
The following are generic DIMM population requirements that generally apply to the Intel®
Server Board S1600JP:

All DIMMs must be DDRIII DIMMs.

Unbuffered DIMMs can be ECC.

Mixing of Registered and Unbuffered DIMMs is not allowed per platform.

Mixing of LRDIMM with any other DIMM type is not allowed per platform.

Mixing of DDRIII voltages is not validated within a socket or across sockets by Intel®. If
1.35V (DDRIIIL) and 1.50V (DDRIII) DIMMs are mixed, the DIMMs will run at 1.50V.

Mixing of DDRIII operating frequencies is not validated within a socket or across sockets
by Intel®. If DIMMs with different frequencies are mixed, all DIMMs will run at the
common lowest frequency.

Quad rank RDIMMs are supported but not validated by Intel®.

A maximum of eight logical ranks (ranks seen by the host) per channel is allowed.

Mixing of ECC and non-ECC DIMMs is not allowed per platform.
3.3.1.3

Publishing System Memory
The BIOS displays the “Total Memory” of the system during POST if Display Logo is
disabled in the BIOS setup. This is the total size of memory discovered by the BIOS
during POST, and is the sum of the individual sizes of installed DDRIII DIMMs
in the system.
Revision 1.4
17
Product Architecture Overview
Intel® Server Board S1600JP TPS

The BIOS displays the “Effective Memory” of the system in the BIOS setup. The term
Effective Memory refers to the total size of all DDRIII DIMMs that are active (not disabled)
and not used as redundant units.

The BIOS provides the total memory of the system in the main page of the BIOS setup.
This total is the same as the amount described by the first bullet above.

If Display Logo is disabled, the BIOS displays the total system memory on the diagnostic
screen at the end of POST. This total is the same as the amount described by the first
bullet above.
3.3.1.4
RAS Features
The server board supports the following memory RAS modes:

Independent Channel Mode
 Rank Sparing Mode
 Mirrored Channel Mode
 Lockstep Channel Mode
Note that support of RAS modes that require matching DIMM population between channels
(Mirrored and Lockstep) require that ECC DIMMs be populated.
For RAS modes that require matching populations, the same slot positions across channels
must hold the same DIMM type with regards to size and organization. DIMM timings do not
have to match but timings will be set to support all the DIMMs populated (that is, DIMMs with
slower timings will force faster DIMMs to the slower common timing modes).
3.3.1.4.1
Independent Channel Mode
Channels can be populated in any order in Independent Channel Mode. All four channels may
be populated in any order and have no matching requirements. All channels must run at the
same interface frequency but individual channels may run at different DIMM timings (RAS
latency, CAS latency, and so forth).
3.3.1.4.2
Rank Sparing Mode
In Rank Sparing Mode, one rank is a spare of the other ranks on the same channel. The spare
rank is held in reserve and is not available as system memory. The spare rank must have
identical or larger memory capacity than all the other ranks (sparing source ranks) on the same
channel. After sparing, the sparing source rank will be lost.
3.3.1.4.3
Mirrored Channel Mode
In Mirrored Channel Mode, the memory contents are mirrored between Channel 0 and Channel 2
and also between Channel 1 and Channel 3. As a result of the mirroring, the total physical
memory available to the system is half of what is populated. Mirrored Channel Mode requires
that Channel 0 and Channel 2, and Channel 1 and Channel 3 must be populated identically with
regards to size and organization. DIMM slot populations within a channel do not have to be
identical, but the same DIMM slot location across Channel 0 and Channel 2 and across Channel
1 and Channel 3 must be populated the same.
3.3.1.4.4
Lockstep Channel Mode
In Lockstep Channel Mode, each memory access is a 128-bit data access that spans Channel 0
and Channel 1, and Channel 2 and Channel 3. Lockstep Channel mode is the only RAS mode
18
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
that allows SDDC for x8 devices. Lockstep Channel Mode requires that Channel 0 and Channel
1, and Channel 2 and Channel 3 must be populated identically with regards to size and
organization. DIMM slot populations within a channel do not have to be identical, but the same
DIMM slot location across Channel 0 and Channel 1 and across Channel 2 and Channel 3 must
be populated the same.
3.3.2
Processor Intergrated I/O Module (I/O)
The processor’s integrated I/O module provides features traditionally supported through chipset
components. The integrated I/O module provides the following features:


PCI Express* Interfaces: The integrated I/O module incorporates the PCI Express*
interface and supports up to 40 lanes of PCI Express*. Following are key attributes of
the PCI Express* interface:
o GenIII speeds at 8 GT/s (no 8b/10b encoding)
o X16 interface bifurcated down to two x8 or four x4 (or combinations)
o X8 interface bifurcated down to two x4
DMI2 Interface to the PCH: The platform requires an interface to the legacy
Southbridge (PCH) which provides basic, legacy functions required for the server
platform and operating systems. Since only one PCH is required and allowed for the
system, any sockets which do not connect to PCH would use this port as a standard x4
PCI Express* 2.0 interface.

Integrated IOAPIC: Provides support for PCI Express* devices implementing legacy
interrupt messages without interrupt sharing.

Non-Transparent Bridge: PCI Express* Non-Transparent Bridge (NTB) acts as a
gateway that enables high performance, low overhead communication between two
intelligent subsystems; the local and the remote subsystems. The NTB allows a local
processor to independently configure and control the local subsystem, provides isolation
of the local host memory domain from the remote host memory domain while enabling
status and data exchange between the two domains.
3.3.2.1
Riser Types
There are three PCIe riser slots on the server board, and they are customized on pin definition.
The riser slot 1 is a standard 164-pin x 16 connector but it is not compatible with standard PCIe
pinout. It has a x16 PCIe GenIII electrical interface. It can be configured as a single x16, dual x8,
or dual x4 plus single x8 (with different risers) if required.
The riser slot 2 is a standard 98-pin x8 connector but it is also not compatible with standard
PCIe pinout. The riser slot 2 supports rIOM mounted on a riser carrier.
The riser slot 3 include two 60-pin connectors that can host a riser with a single PCIe GenIII x16
(electrical/mechanical) slot for a double width PCI Express* card or dual PCIe GenIII x8
(electrical/mechanical) slots for general purpose boards.
Revision 1.4
19
Product Architecture Overview
Intel® Server Board S1600JP TPS
Each riser slot support will have the power budget as shown in the following table:
Table 9. Power budget for riser slot
Riser Slot#
12V Capability
3.3V Capability
Riser Slot 1
2A
6A
Riser Slot 2
1A
3A
Riser Slot 3
5.5A
6A
Supported 1U riser cards include:

1U low profile Riser slot 1 with one PCIe slot – It provides electrical connectivity for a
PCIe x16 GenIII low profile adapter card. It supports a PCIe GenIII X16 card edge
connection and a x16/x16 mech PCIe connector. The X16 PCIe card edge connection
are not compatible with the standard PCIe pinout but the x16 PCIe connector is
compatible. Product Code: F1UJP1X16RISER.
Figure 9. PCIe Riser for Slot 1

20
1U Riser for Slot 2 with one PCIe slot – It supports PCIe GenIII x8 connection to the IOM
module and a RGMII interface across to the IOM Carrier Board. The x8 PCIe card edge
connection and x8 PCIe connector do not follow the standard PCIe pinout. Product Code:
A1UJPRMM4IOM.
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
Figure 10. PCIe Riser for Slot 2
Figure 11. Riser Carrier Board

1U PCIe double width PCI Express* card Riser for slot 3 with one PCIe slot - It provides
electrical connectivity for a PCIe x16 GenIII double width PCI Express* card. It supports
a PCIe GenIII 2X60pin card edge connection and a x16/x16 mech PCIe connector. The
2X60 pin PCIe card edge connection are not compatible with the standard PCIe pinout
but the x16 PCIe connector is compatible. Product Code: F1UJPMICRISER.
Revision 1.4
21
Product Architecture Overview
Intel® Server Board S1600JP TPS
Figure 12. 1U PCIe Double Width PCI Express* Card Riser for Slot3

1U PCIe FHFL Riser for slot 3 with two PCIe slots - It provides electrical connectivity for
two standard PCIe x8 GenIII FHFL PCIE card. It supports x2 60 pin PCIE card edge and
one GenIII x8/x16 mech PCIE connector and one GenIII x8/x8 mech PCIE connector.
The 2x60 pin PCIe card connection are not compatible with the standard PCIe pinout,
but the two PCIe connectors are compatible. Product Code: F1UJP2X8RISER.
Figure 13. 1U PCIe FHFL Riser for Slot3
3.3.2.2
Network Interface
The on-board Intel® i350 Ethernet controller provides four/two 10/100/1000Gbps Ethernet ports
in four/two RJ45 ports in S1600JP4/S1600JP2.
22
Revision 1.4
Intel® Server Board S1600JP TPS
3.3.2.3
Product Architecture Overview
I/O Module Support
To broaden the standard on-board feature set, the server board supports the option of adding a
single I/O module providing external ports for a variety of networking interfaces. The I/O module
attaches to a high density 80-pin connector of I/O module carrier on the Riser 2.
3.4
Intel® C600-A PCH Functional Overview
The following sub-sections will provide an overview of the key features and functions of the
Intel® C600-A chipset used on the server board. For more comprehensive chipset specific
information, refer to the Intel® C600-A Series chipset documents through:
http://www.intel.com/content/www/us/en/chipsets/server-chipsets/server-workstationchipsets.html. Figure 14. Intel® C600-A PCH connection
The Intel® C600-A PCH component provides extensive I/O support. Functions and
capabilities include:

PCI Express* Base Specification, Revision 2.0 support for up to eight ports with transfers
up to 5 GT/s.

PCI Local Bus Specification, Revision 2.3 support for 33 MHz PCI operations (supports
up to four Req/Gnt pairs).

ACPI Power Management Logic Support, Revision 4.0a

Enhanced DMA controller, interrupt controller, and timer functions

Integrated Serial Attached SCSI host controllers at transfer rate up to 6Gb/s on up to
eight ports.

Integrated Serial ATA host controllers with independent DMA operation on up to six
ports.

USB host interface with two EHCI high-speed USB 2.0 Host controllers and 2 rate
matching hubs provide support for support for up to fourteen USB 2.0 ports.

Integrated 10/100/1000 Gigabit Ethernet MAC with System Defense

System Management Bus (SMBus*) Specification, Version 2.0 with additional support for
I2C* devices.

Supports Intel® High Definition Audio

Supports Intel® Rapid Storage Technology (Intel® RST)
Revision 1.4
23
Product Architecture Overview
Intel® Server Board S1600JP TPS

Supports Intel® Virtualization Technology for Directed I/O (Intel® VT-d)

Supports Intel® Trusted Execution Technology (Intel® TXT)

Low Pin Count (LPC) interface

Firmware Hub (FWH) interface support

Serial Peripheral Interface (SPI) support

Intel® Anti-Theft Technology (Intel® AT)

JTAG Boundary Scan support
3.4.1
PCI Express*
The Intel® C600 PCH provides up to eight PCI Express* Root Ports, supporting the PCI
Express* Base Specification, Revision 2.0. Each Root Port x1 lane supports up to 5 Gb/s
bandwidth in each direction (10 Gb/s concurrent). PCI Express* Root Ports 1-4 or Ports 5-8 can
independently be configured to support four x1s, two x2s, one x2 and two x1s, or one x4
port widths.
From PCH on Intel® Server Board S1600JP, PCIe Port8 x1 GenII is connected to BMC Gen1
Uplink. Ports 1-4 are connected to Intel® I350 GbE NIC. The remaining PCIe GenII interconnect
(Port 5-7, 1 based numbering) are unused.
3.4.2
Universal Serial Bus (USB)
There are fourteen USB 2.0 ports available from Intel® C600 PCH. All ports are high-speed, fullspeed, and low-speed capable. A total of 7 USB 2.0 dedicated ports are used by Intel® Server
Board S1600JP. The USB port distribution is as follows:


Emulex* BMC PILOT III consumes two USB 2.0 ports (one USB1.1 and one USB2.0)
Two rear USB 2.0 ports

Two internal USB port for extension of front-panel USB port.

One Type-A USB port
Note: Intel® Server Board S1600JP supports three high power USB ports (1 at rear port, 1 at
internal USB port1 and 1 at internal USB port2) + 4 low power USB ports at the same time.
3.4.3
Serial Attached SCSI (SAS) and Serial ATA (SATA) Controller
The Intel® C600-A chipset provides storage support through two integrated controllers: AHCI
and SCU. By default, the server board supports up to six SATA ports: Two single 6Gb/sec
SATA ports and four 3Gb/s SATA ports. The board supports up to four 3Gb/s SATA/SAS ports
from the mini-SAS port.
It supports the Serial ATA Specification, Revision 3.0, and several optional sections of the Serial
ATA II: Extensions to Serial ATA 1.0 Specification, Revision 1.0 (AHCI support is required for
some elements).
Intel® Server Board S1600JP implements six SATA/SAS ports. The implementation is
as follows:
24
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
Table 10. Intel® Server Board S1600JP SATA/SAS port
Port#
Speed
Connector
0
6Gb/s SATA
On Server board
1
6Gb/s SATA
On Server board
2
3Gb/s SATA
On Server board
3
3Gb/s SATA
On Server board
4
3Gb/s SATA
On Server board
3Gb/s SATA
On Server board
3Gb/s SATA/SAS
On board mini SAS
5
0
1
SCU0
2
3
There are two embedded software RAID options using the storage ports configured from the
SCU only:

Intel® Embedded Server RAID Technology 2 (ESRT2) based on LSI* MegaRAID SW
RAID technology supporting SATA RAID levels 0,1,10, 5.

Intel® Rapid Storage Technology (RSTe) supporting SATA RAID levels 0, 1, 5, and 10.
The server board is capable of supporting additional chipset embedded SAS and RAID options
from the SCU controller when configured with one of the several available Intel® RAID C600
Storage Upgrade Keys. Upgrade keys install onto a 4-pin connector on the server board labeled
“SAS/SATA Key”.
The following table identifies available upgrade key options and their supported features:
Table 11. Intel® RAID C600 Storage Upgrade Key Options for S1600JP
Intel® RAID C600 Upgrade Key
Options (Intel® Product Codes)
Key Color
Description
®
®
Default – No option key installed
N/A 4 Port SATA with Intel ESRT RAID 0,1,10 and Intel
RSTe RAID 0,1,5,10
RKSATA4R5
Black 4 Port SATA with Intel ESRT2 RAID 0,1, 5, 10, and
®
Intel RSTe RAID 0,1,5,10
RKSAS4
Green 4 Port SAS with Intel ESRT2 RAID 0,1,10 and Intel
RSTe RAID 0,1,10
RKSAS4R5
Yellow 4 Port SAS with Intel ESRT2 RAID 0,1, 5, 10 and
®
Intel RSTe RAID 0,1,10
Revision 1.4
®
®
®
®
25
Product Architecture Overview
3.4.4
Intel® Server Board S1600JP TPS
PCI Interface
®
The Intel C600 PCH PCI Interface provides a 33 MHz, Revision 2.3 implementation. It
integrates a PCI arbiter that supports up to four external PCI bus masters in addition to the PCH
internal requests. This allows for combinations of up to four PCI down devices and
PCI slots.
3.4.5
Low Pin Count (LPC) Interface
The Intel® C600 PCH implements an LPC Interface as described in the LPC 1.1 Specification.
The Low Pin Count (LPC) bridge function of the PCH resides in PCI Device 31: Function 0. In
addition to the LPC bridge interface function, D31:F0 contains other functional units including
DMA, interrupt controllers, timers, power management, system management, GPIO, and RTC.
3.4.6
Digital Media Interface (DMI)
Digital Media Interface (DMI) is the chip-to-chip connection between the processor and Intel®
C600 PCH. This high-speed interface integrates advanced priority-based servicing allowing for
concurrent traffic and true isochronous transfer capabilities. Base functionality is completely
software-transparent, permitting current, and legacy software to operate normally.
3.4.7
Serials Peripheral Interface (SPI)
®
The Intel C600 PCH implements an SPI Interface as an alternative interface for the BIOS flash
device. An SPI flash device can be used as a replacement for the FWH, and is required to
support Gigabit Ethernet and Intel® Active Management Technology. The PCH supports up to
two SPI flash devices with speeds up to 50 MHz, utilizing two chip select pins.
3.4.8
Compatibility Modules (DMA Controller, Timer/Counters, Interrupt Controller)
The DMA controller incorporates the logic of two 8237 DMA controllers, with seven
independently programmable channels. Channels 0–3 are hardwired to 8-bit, count-by-byte
transfers, and channels 5–7 are hardwired to 16-bit, count-by-word transfers. Any two of the
seven DMA channels can be programmed to support fast Type-F transfers. Channel 4 is
reserved as a generic bus master request.
The Intel® C600 PCH supports LPC DMA, which is similar to ISA DMA, through the PCH’s DMA
controller. LPC DMA is handled through the use of the LDRQ# lines from peripherals and
special encoding on LAD[3:0] from the host. Single, Demand, Verify, and Increment modes are
supported on the LPC interface.
The timer/counter block contains three counters that are equivalent in function to those found in
one 8254 programmable interval timer. These three counters are combined to provide the
system timer function, and speaker tone. The 14.31818 MHz oscillator input provides the clock
source for these three counters.
The Intel® C600 PCH provides an ISA-Compatible Programmable Interrupt Controller (PIC) that
incorporates the functionality of two, 8259 interrupt controllers. The two interrupt controllers are
cascaded so that 14 external and two internal interrupts are possible. In addition, the PCH
supports a serial interrupt scheme. All of the registers in these modules can be read and
restored. This is required to save and restore system state after power has been removed and
restored to the platform.
26
Revision 1.4
Intel® Server Board S1600JP TPS
3.4.9
Product Architecture Overview
Advanced Programmable Interrupt Controller (APIC)
In addition to the standard ISA compatible Programmable Interrupt Controller (PIC) described in
the previous section, the Intel® C600 PCH incorporates the Advanced Programmable Interrupt
Controller (APIC).
3.4.10
Real Time Clock (RTC)
®
The Intel C600 PCH contains a Motorola* MC146818B-compatible real-time clock with 256
bytes of battery-backed RAM. The real-time clock performs two key functions: keeping track of
the time of day and storing system data, even when the system is powered down. The RTC
operates on a 32.768 KHz crystal and a 3V battery. The RTC also supports two lockable
memory ranges. By setting bits in the configuration space, two 8-byte ranges can be locked to
read and write accesses. This prevents unauthorized reading of passwords or other system
security information. The RTC also supports a date alarm that allows for scheduling a wake up
event up to 30 days in advance, rather than just 24 hours in advance.
3.4.11
GPIO
Various general purpose inputs and outputs are provided for custom system design. The
number of inputs and outputs varies depending on the Intel® C600 PCH configuration.
3.4.12
Enhanced Power Management
®
The Intel C600 PCH power management functions include enhanced clock control and various
low-power (suspend) states. A hardware-based thermal management circuit permits softwareindependent entrance to low-power states. The PCH contains full support for the Advanced
Configuration and Power Interface (ACPI) Specification, Revision 4.0a.
3.4.13
Fan Speed Control
®
The Intel C600 PCH integrates four fan speed sensors (four TACH signals) and four fan speed
controllers (three Pulse Width Modulator signals), which enables monitoring and controlling up
to four fans on the system. With the new implementation of the single-wire Simple Serial
Transport (SST) 1.0 bus and Platform Environmental Control Interface (PECI), the PCH
provides an easy way to connect to SST-based thermal sensors and access the processor
thermal data.
3.4.14
Intel® Virtualization Technology for Direct I/O (Intel® VT-d)
The Intel® Virtualization Technology is designed to support multiple software environments
sharing same hardware resources. Each software environment may consist of an OS and
applications. The Intel® Virtualization Technology can be enabled or disabled in the BIOS setup.
The default behavior is disabled.
Note: If the setup options are changed to enable or disable the Virtualization Technology setting
in the processor, the user must perform an AC power cycle for the changes to take effect.
The chipset supports DMA remapping from inbound PCI Express* memory Guest Physical
Address (GPA) to Host Physical Address (HPA). PCI devices are directly assigned to a virtual
machine leading to a robust and efficient virtualization.
Revision 1.4
27
Product Architecture Overview
3.4.15
Intel® Server Board S1600JP TPS
KVM/Serial Over LAN (SOL) Function
These functions support redirection of keyboard, mouse, and text screen to a terminal window
on a remote console. The keyboard, mouse, and text redirection enables the control of the client
machine through the network without the need to be physically near that machine. Text, mouse,
and keyboard redirection allows the remote machine to control and configure the client by
entering BIOS setup. The KVM/SOL function emulates a standard PCI serial port and redirects
the data from the serial port to the management console using LAN. KVM has additional
requirements of internal graphics and SOL may be used when KVM is not supported.
3.4.16
IDE-R Function
The IDE-R function is an IDE Redirection interface that provides client connection to
management console ATA/ATAPI devices. When booting from IDE-R, the IDE-R interface will
send the client’s ATA/ATAPI command to the management console. The management console
will then provide a response command back to the client. A remote machine can setup a
diagnostic SW or OS installation image and direct the client to boot from IDE-R. The IDE-R
interface is the same as the IDE interface and is compliant with ATA/ATAPI-6 specifications.
IDE-R does not conflict with the usage of PXE boot. The system can support both interfaces
and continue to boot from the PXE as with any other boot devices. However, during
management boot session the Intel® AMT solution will use IDE-R when remote boot is required.
The devices attached to the IDER channel are only visible to software during management boot
session. During normal boot session the IDE-R channel does not appear as a present device.
3.4.17
Manageability
®
Intel C600 PCH integrates several functions designed to manage the system and lower the
Total Cost of Ownership (TCO) of the system. These system management functions are
designed to report errors, diagnose the system, and recover from system lockups without the
aid of an external microcontroller. The functionality provided by the SPS firmware is different
from Intel® Active Management Technology (Intel® AMT or AT) provided by the ME on
client platforms.
28

TCO Timer: The Intel® C600 PCH’s integrated programmable TCO timer is used to
detect system locks. The first expiration of the timer generates an SMI# that the system
can use to recover from a software lock. The second expiration of the timer causes a
system reset to recover from a hardware lock.

Processor Present Indicator: The Intel® C600 PCH looks for the processor to fetch the
first instruction after reset. If the processor does not fetch the first instruction, the PCH
will reboot the system.

ECC Error Reporting: When detecting an ECC error, the host controller has the ability
to send one of several messages to the Intel® C600 PCH. The host controller can
instruct the PCH to generate any of SMI#, NMI, SERR#, or TCO interrupt.

Function Disable: The Intel® C600 PCH provides the ability to disable the following
integrated functions: LAN, USB, LPC, Intel® HD Audio, SATA, PCI Express*, or SMBus*.
Once disabled, these functions no longer decode I/O, memory, or PCI configuration
space. Also, no interrupts or power management events are generated from the disabled
functions.

Intruder Detect: The Intel® C600 PCH provides an input signal (INTRUDER#) that can
be attached to a switch that is activated by the system case being opened. The Intel®
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
C600 PCH can be programmed to generate either SMI# or TCO interrupt due to an
active INTRUDER# signal.
3.4.18
System Management Bus (SMBus* 2.0)
®
The Intel C600 PCH contains a SMBus* Host interface that allows the processor to
communicate with SMBus* slaves. This interface is compatible with most I2C devices. Special
I2C commands are implemented.
The Intel® C600 PCH’s SMBus* host controller provides a mechanism for the processor to
initiate communications with SMBus* peripherals (slaves). Also, the PCH supports slave
functionality, including the Host Notify protocol. Hence, the host controller supports eight
command protocols of the SMBus* interface (see System Management Bus (SMBus*)
Specification, Version 2.0): Quick Command, Send Byte, Receive Byte, Write Byte/Word, Read
Byte/Word, Process Call, Block Read/Write, and Host Notify.
The Intel® C600 PCH’s SMBus* also implements hardware-based Packet Error Checking for
data robustness and the Address Resolution Protocol (ARP) to dynamically provide address to
all SMBus* devices.
3.4.19
Network Interface Controller (NIC)
Network interface support is provided from the onboard Intel® I350 NIC, which is a dual-port,
compact component with two fully integrated GbE Media Access Control (MAC) and Physical
Layer (PHY) ports. The Intel® I350 NIC provides the server board with support for dual LAN
ports designed for 10/100/1000 Mbps operation. Refer to the Intel® I350 Gigabit Ethernet
Controller Datasheet for full details of the NIC feature set.
The NIC device provides a standard IEEE 802.3 Ethernet interface for 1000BASE-T, 100BASETX, and 10BASE-T applications (802.3, 802.3u, and 802.3ab) and is capable of transmitting and
receiving data at rates of 1000 Mbps, 100 Mbps, or 10 Mbps.
The Intel® I350 controller also requires the use of Intel® C600 PCH SMBus* interface during
Sleep states S4 and S5 as well as for ME Firmware. The Intel® I350 LAN controller will be on
standby power so that Wake on LAN and manageability functions can be supported.
Intel® I350 will be used in conjunction with the Emulex* PILOT III BMC for in band Management
traffic. The BMC will communicate with Intel® I350 over a NC-SI interface (RMII physical). The
NIC will be on standby power so that the BMC can send management traffic over the NC-SI
interface to the network during sleep states S4 and S5.
The NIC supports the normal RJ-45 LINK/Activity speed LEDs as well as the Proset ID function.
These LEDs are powered from a Standby voltage rail.
S1600JP4 has Quad NIC ports. S1600JP2 has Dual NIC ports.
The link/activity LED (at the right of the connector) indicates network connection when on, and
transmit/receive activity when blinking. The speed LED (at the left of the connector) indicates
1000-Mbps operation when green, 100-Mbps operation when amber, and 10-Mbps when off.
The following table provides an overview of the LEDs.
Revision 1.4
29
Product Architecture Overview
Intel® Server Board S1600JP TPS
Figure 15. 1GbE NIC port LED
Table 12. NIC Status LED
LED Color
Green/Amber (B)
Green (A)
3.4.19.1
LED State
NIC State
Off
10 Mbps
Amber
100 Mbps
Green
1000 Mbps
On
Active Connection
Blinking
Transmit/Receive activity
MAC Address Definition
®
The Intel Server Board S1600JP2 has the following four MAC addresses assigned to it at the
Intel® factory.





NIC 1 MAC address
NIC 2 MAC address = NIC 1 MAC address + 1
Integrated BMC LAN channel 1 MAC address = NIC1 MAC address + 2
Integrated BMC LAN channel 2 MAC address = NIC1 MAC address + 3
Integrated BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 4
The Intel® Server Board S1600JP4 has the following four MAC addresses assigned to it at the
Intel® factory.
 NIC 1 MAC address
 NIC 2 MAC address = NIC 1 MAC address + 1
 NIC 3 MAC address = NIC 1 MAC address + 2
 NIC 4 MAC address = NIC 1 MAC address + 3
 Integrated BMC LAN channel 1 MAC address = NIC1 MAC address + 4
 Integrated BMC LAN channel 2 MAC address = NIC1 MAC address + 5
 Integrated BMC LAN channel 3 (RMM) MAC address = NIC1 MAC address + 6
The Intel® Server Board S1600JP has a white MAC address sticker included with the board.
The sticker displays the NIC 1 MAC address in both barcode and alphanumeric formats.
3.4.19.2
LAN Manageability
Port2 of the Intel® I350 NIC will be used by the BMC firmware to send management traffic. In
standby in order to save power, Port2 will be the only port to support Wake on LAN. The
30
Revision 1.4
Intel® Server Board S1600JP TPS
Product Architecture Overview
EEPROM is programmed to turn off this feature from the other ports in order to maximize power
savings during sleep states.
3.4.19.3
Wake-On-LAN
WOL is supported on the Intel® I350 LAN controller for all supported Sleep states.
3.4.19.4
Intel® i350 Thermal Sensor
Intel® i350 NIC will have an integrated digital thermal sensor accessible through CSR and
manageability registers. The thermal sensor can be programmed to trigger digital pins and
thermal throttling with hysteresis.
3.5
Integrated Baseboard Management Controller Overview
The server board utilizes the Baseboard Management features of the Emulex* Pilot III Server
Management Controller. The following is an overview of the features as implemented on the
server board from each embedded controller.
Figure 16. Integrated BMC implementation overview (S1600JP2)
Revision 1.4
31
Product A
Architecture Ovverview
Intel® S
Server Board S
S1600JP TPS
Figure 17. Integrated BMC Func
ctional Bloc
ck Diagram
The Inte
egrated BMC
C is provide
ed by an em
mbedded AR
RM9 controller and asso
ociated periipheral
function
nality that is required for IPMI-base
ed server ma
anagement. Firmware usage of these
hardwarre features is platform dependent.
d
The follo
owing is a ssummary of the Integrated BMC managementt hardware ffeatures tha
at
comprisse the BMC::










32
400MHz 32-bit ARM9 p
4
processor with
w memoryy management unit (MM
MU)
T
Two
indepe
endent 10/10
00/1000 Eth
hernet Controllers with RMII/RGMIII support
D
DDRII/III
16
6-bit interfacce with up to
o 800 MHz operation
o
12 10-bit AD
DCs
16 fan tacho
ometers
E
Eight
Pulse Width Mod
dulators (PW
WM)
C
Chassis
intrrusion logic
J
JTAG
Maste
er
2
E
Eight
I C intterfaces with master-slave and SM
MBus* timeo
out support. All interface
es are
S
SMBus*
2.0
0 compliant.
P
Parallel
gen
neral-purposse I/O Portss (16 direct a
and 32 sharred)
R
Revision 1.4
Intel® Server Board S1600JP TPS














Product Architecture Overview
Serial general-purpose I/O Ports (80 in and 80 out)
Three UARTs
Platform Environmental Control Interface (PECI)
Six general-purpose timers
Interrupt controller
Multiple SPI flash interfaces
NAND/Memory interface
Sixteen mailbox registers for communication between the BMC and host
LPC ROM interface
BMC watchdog timer capability
SD/MMC card controller with DMA support
LED support with programmable blink rate controls on GPIOs
Port 80h snooping capability
Secondary Service Processor (SSP), which provides the HW capability of offloading time
critical processing tasks from the main ARM core.
Emulex* Pilot III contains an integrated SIO, KVMS subsystem, and graphics controller with the
following features:
3.5.1
Super I/O Controller
The integrated super I/O controller provides support for the following features as implemented
on the server board:







Keyboard Style/BT interface for BMC support
Two Fully Functional Serial Ports, compatible with the 16C550
Serial IRQ Support
Up to 16 Shared GPIO available for host processor
Programmable Wake-up Event Support
Plug and Play Register Set
Power Supply Control
3.5.1.1
Keyboard and Mouse Support
The server board does not support PS/2 interface keyboards and mice. However, the system
BIOS recognizes USB specification-compliant keyboards and mice.
3.5.1.2
Wake-up Control
The super I/O contains functionality that allows various events to power on and power off
the system.
3.5.2
Graphics Controller and Video Support
The integrated graphics controller provides support for the following features as implemented on
the server board:

Integrated Graphics Core with 2D Hardware accelerator
Revision 1.4
33
Product Architecture Overview
Intel® Server Board S1600JP TPS
 DDR-II/III memory interface supports up to 256MB of memory
 Supports all display resolutions up to 1600 x 1200 16bpp @ 60Hz
 High speed Integrated 24-bit RAMDAC
The integrated video controller supports all standard IBM VGA modes. The following table
shows the 2D modes supported for both CRT and LCD:
Table 13. Video Modes
2D Mode
Refresh Rate (Hz)
2D Video Mode Support
8 bpp
16 bpp
32 bpp
640x480
60, 72, 75, 85, 90,
100, 120, 160, 200
Supported
Supported
Supported
800x600
60, 70, 72, 75, 85,
90, 100, 120,160
Supported
Supported
Supported
1024x768
60, 70, 72,
75,85,90,100
Supported
Supported
Supported
1152x864
43,47,60,70,75,80,85
Supported
Supported
Supported
1280x1024
60,70,74,75
Supported
Supported
Supported
1600x1200**
60
Supported
Supported
Supported
** Video resolutions at 1600x1200 are only supported through the external video
connector located on the rear I/O section of the server board. Utilizing the
optional front panel video connector may result in lower video resolutions.
The server board provides two video interfaces. The primary video interface is accessed using a
standard 15-pin VGA connector found on the back edge of the server board. In addition, video
signals are routed to a 14-pin header labeled “FP_Video” on the leading edge of the server
board, allowing for the option of cabling to a front panel video connector. Attaching a monitor to
the front panel video connector will disable the primary external video connector on the back
edge of the board.
The BIOS supports dual-video mode when an add-in video card is installed. In the single mode
(dual monitor video = disabled), the on-board video controller is disabled when an add-in video
card is detected.
In the dual mode (on-board video = enabled, dual monitor video = enabled), the on-board video
controller is enabled and is the primary video device. The add-in video card is allocated
resources and is considered the secondary video device. The BIOS Setup utility provides
options to configure the feature as follows:
Table 14. Video mode
34
On-board Video
Enabled
Disabled
Dual Monitor Video
Enabled
Disabled
Shaded if on-board video is set to "Disabled"
Revision 1.4
Intel® Server Board S1600JP TPS
3.5.3
Product Architecture Overview
Remote KVM
The Integrated BMC contains a remote KVMS subsystem with the following features:







USB 2.0 interface for Keyboard, Mouse, Video, and Remote storage such as CD/DVD
ROM and floppy
USB 1.1/USB 2.0 interface for PS2 to USB bridging, remote Keyboard, and Mouse
Hardware Based Video Compression and Redirection Logic
Supports both text and Graphics redirection
Hardware assisted Video redirection using the Frame Processing Engine
Direct interface to the Integrated Graphics Controller registers and Frame buffer
Hardware-based encryption engine
Revision 1.4
35
Intel® Server Board S1600JP TPS
4.
Platform Management Functional Overview
Platform Management Functional Overview
Platform management functionality is supported by several hardware and software components
integrated on the server board that work together to control system functions, monitor and report
system health, and control various thermal and performance features in order to maintain (when
possible) server functionality in the event of component failure and/or environmentally stressed
conditions.
This chapter provides a high level overview of the platform management features and
functionality implemented on the server board. For more in depth and design level Platform
Management information, refer the BMC Core Firmware External Product Specification (EPS)
(Intel® Order Number: G31813) and BIOS Core External Product Specification (EPS) for Intel®
Server products based on the Intel® Xeon® processor E5-4600, 2600, and 1600 product families.
4.1
Baseboard Management Controller (BMC) Firmware Feature Support
The following sections outline general features that the integrated BMC firmware can support.
Support and utilization for some features is dependent on the server platform in which the
server board is integrated and any additional system level components and options that may
be installed.
4.1.1
IPMI 2.0 Features












36
Baseboard Management Controller (BMC)
IPMI Watchdog timer
Messaging support, including command bridging and user/session support.
Chassis device functionality, including power/reset control and BIOS boot
flags support.
Event receiver device: The BMC receives and processes events from other
platform subsystems.
Field Replaceable Unit (FRU) inventory device functionality: The BMC supports
access to system FRU devices using IPMI FRU commands.
System Event Log (SEL) device functionality: The BMC supports and provides
access to a SEL.
Sensor Data Record (SDR) repository device functionality: The BMC supports
storage and access of system SDRs.
Sensor device and sensor scanning/monitoring: The BMC provides IPMI
management of sensors. It polls sensors to monitor and report system health.
IPMI interfaces:
o Host interfaces include system management software (SMS) with receive
message queue support, and server management mode (SMM).
o IPMB interfaces
o LAN interface that supports the IPMI-over-LAN protocol (RMCP and RMCP+)
Serial-over-LAN (SOL)
ACPI state synchronization: The BMC tracks ACPI state changes that are provided
by the BIOS.
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS

BMC self-test: The BMC performs initialization and run-time self-tests and makes
results available to external entities.
See also the Intelligent Platform Management Interface Specification Second Generation v2.0.
4.1.2
Non-IPMI Features
The BMC supports the following non-IPMI features. This list does not preclude support for future
enhancements or additions.

























Revision 1.4
In-circuit BMC firmware update
BMC FW reliability enhancements:
o Redundant BMC boot blocks to avoid possibility of a corrupted boot block
resulting in a scenario that prevents a user from updating the BMC.
o
BMC System Management Health Monitoring
o
Signed firmware images for increased security
Fault resilient booting (FRB): FRB2 is supported by the watchdog timer functionality
Enable/Disable of System Reset Due CPU Errors
Chassis intrusion detection
Fan speed control
Fan redundancy monitoring and support
Hot-swap fan support
Power Supply Fan Sensors
System Airflow Monitoring
Exit Air Temperature Monitoring
Acoustic management: Support for multiple fan profiles
Ethernet Controller Thermal Monitoring
Global Aggregate Temperature Margin Sensor
Platform environment control interface (PECI) thermal management support
Memory Thermal Management
DIMM temperature monitoring: New sensors and improved acoustic management
using closed-loop fan control algorithm taking into account DIMM temperature
readings.
Power supply redundancy monitoring and support
Power unit management: Support for power unit sensor. The BMC handles powergood dropout conditions.
Intel® Intelligent Power Node Manager support
Signal testing support: The BMC provides test commands for setting and getting
platform signal states.
The BMC generates diagnostic beep codes for fault conditions
System GUID storage and retrieval
Front panel management: The BMC controls the system status LED and chassis ID
LED. It supports secure lockout of certain front panel functionality and monitors
button presses. The chassis ID LED is turned on using a front panel button or
a command.
Power state retention
37
Intel® Server Board S1600JP TPS














Power fault analysis
Intel® Light-Guided Diagnostics
Address Resolution Protocol (ARP): The BMC sends and responds to ARPs
(supported on embedded NICs)
Dynamic Host Configuration Protocol (DHCP): The BMC performs DHCP (supported
on embedded NICs)
E-mail alerting
Embedded web server
o Support for embedded web server UI in Basic Manageability feature set
o
Human-readable SEL
o
Additional system configurability
o
Additional system monitoring capability
o
Enhanced on-line help
Integrated KVM
Integrated Remote Media Redirection
Local Directory Access Protocol (LDAP) support
Sensor and SEL logging additions/enhancements (for example, additional thermal
monitoring capability)
SEL Severity Tracking and the Extended SEL
BMC Data Repository (Managed Data Region Feature)
Embedded platform debug feature which allows capture of detailed data for
later analysis
Provisioning and inventory enhancements:
o Signed Firmware (improved security)
o







4.1.3
Platform Management Functional Overview
Inventory data/system information export (partial SMBIOS table)
DCMI 1.1 compliance
Management support for PMBus* rev1.2 compliant power supplies
Energy Star Server Support
SmaRT/CLST
Power Supply Cold Redundancy
Power Supply FW Update for supported Intel® supplies
Power Supply Compatibility Check
New Manageability Features
The new generation EPSD server products offer a number of changes and additions to the
manageability features that are supported on the previous generation of servers. The following
is a list of the more significant changes that are common to all EPSD servers of this
new generation:



38
Sensor and SEL logging additions/enhancements (for example, additional thermal
monitoring capability)
SEL Severity Tracking and the Extended SEL
Embedded platform debug feature which allows capture of detailed data for later
analysis.
Revision 1.4
Platform Management Functional Overview





















4.2
Intel® Server Board S1600JP TPS
Provisioning and inventory enhancements:
o Signed Firmware (improved security)
o Inventory data/system information export (partial SMBIOS table)
Enhancements to fan speed control
DCMI 1.1 compliance
Support for embedded web server UI in basic manageability feature set
Enhancements to embedded web server
o Human-readable SEL
o Additional system configurability
o Additional system monitoring capability
o Enhanced on-line help
Enhancements to KVM redirection
o Support resolution up to 1600x1200
Management support for PMBus* rev1.2 compliant power supplies
BMC Data Repository (Managed Data Region Feature)
System Airflow Monitoring Exit Air Temperature Monitoring Ethernet Controller Thermal Monitoring
Global Aggregate Temperature Margin Sensor
Memory Thermal Management
Power Supply Fan Sensors
Enable/Disable of System Reset Due CPU Errors
Energy Star Server Support
SmaRT/CLST
Power Supply Cold Redundancy
Power Supply FW Update
Power Supply Compatibility Check
BMC FW reliability enhancements:
o Redundant BMC boot blocks to avoid possibility of a corrupted boot block
resulting in a scenario that prevents a user from updating the BMC.
o BMC System Management Health Monitoring
Advanced Configuration and Power Interface (ACPI)
The server board has support for the following ACPI states:
Table 15. ACPI Power States
State
S0
Supported
Yes
Description
Working.
 The front panel power LED is on (not controlled by the BMC).
 The fans spin at the normal speed, as determined by sensor inputs.
 Front panel buttons work normally.
Revision 1.4
39
Intel® Server Board S1600JP TPS
State
Supported
Platform Management Functional Overview
Description
S1
Yes
Sleeping. Hardware context is maintained; equates to processor and chipset clocks being
stopped.
 The front panel power LED blinks at a rate of 1 Hz with a 50% duty cycle (not controlled
by the BMC).
 The watchdog timer is stopped.
 The power, reset, front panel NMI, and ID buttons are unprotected.
 Fan speed control is determined by available SDRs. Fans may be set to a fixed state, or
basic fan management can be applied.
The BMC detects that the system has exited the ACPI S1 sleep state when the BIOS SMI
handler notifies it.
S2
No
Not supported.
S3
No
Supported only on Workstation platforms. See appropriate Platform Specific Information for
more information.
S4
No
Not supported.
S5
Yes
Soft off.




4.3
The front panel buttons are not locked.
The fans are stopped.
The power-up process goes through the normal boot process.
The power, reset, front panel NMI, and ID buttons are unlocked.
Platform Management SMBus* and I2C Implementation
SMBus*/ I2C interconnections are a fundamental interface for various manageability
components. There are three buses that are used in a multi-master fashion.
Primary IPMB. An IPMB header is provided on the baseboard to support connectivity
with third-party management PCIe cards. This bus operates as 100 kHz bus.
 Secondary IPMB. This is the SMLink0 bus that connects the BMC with the ME in the
SSB. This bus is considered a secondary IPMB. The ME and BMC communicate over
this bus using IPMB protocol messages. Any devices on the bus must be 400 kHz
bus tolerant.
 PMBus*. This is the SMLink1 bus that both the ME and BMC use to communicate with
the power supplies. This bus operates as 100 kHz bus.
For all multi-master buses, the master that initiates a transaction is responsible for any bus
recovery sequence if the bus hangs.

The BMC acts as master for the other buses connected to it.
4.4
BMC Internal Timestamp Clock
The BMC maintains an internal timestamp clock that is used by various BMC subsystems, for
example, for time stamping SEL entries. As part of BMC initialization after AC power is applied
or the BMC is reset, the BMC initializes this internal clock to the value retrieved from the SSB
component’s RTC through a SMBus* slave read operation. This is the system RTC and is on
the battery power well so it maintains the current time even when there is no AC supplied to
the system.
The BMC reads the RTC using the same SMBus* (the “host SMBus*”) that is used by BIOS
during POST, so the BMC FW must not attempt to access the RTC between the time the
40
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
system is reset or powered-on and POST completes, as indicated by the assertion of the POSTcomplete signal. Additionally, the BMC should cancel any pending reads of the RTC if the
POST-complete signal deasserts (for example, due to a reset). Normally the BMC reads the
RTC when AC power is first applied and before the system is powered-on, so this is not a
concern. However, if AC power is applied and the power button is immediately pressed, it is
possible that POST would be in progress by the time the BMC is ready to read the RTC.
Another potential conflict can occur if the BMC gets reset and POST is in progress when the
BMC has re-initialized. For either of these cases, the BMC FW initializes its internal time clock
to 0 and begins counting up from there. When POST completes, BIOS will then update the
BMC’s time clock to the current system time.
The BMC’s internal timestamp clock is read and set using the Get SEL Time and Set SEL Time
commands, respectively. The Get SDR Time command can also be used to read the timestamp
clock. These commands and the IPMI time format are specified in the IPMI 2.0 specification.
Whenever the BMC receives the Set SEL Time command, it updates only its internal time clock.
Note that an update of this internal time clock does not result in a change to the system RTC.
4.5
Sensor Monitoring
The BMC monitors system hardware and reports system health. The information gathered from
physical sensors is translated into IPMI sensors as part of the “IPMI Sensor Model”. The BMC
also reports various system state changes by maintaining virtual sensors that are not
specifically tied to physical hardware.
4.6
Messaging Interfaces
The supported BMC communication interfaces include:




Host SMS interface by means of low pin count (LPC)/keyboard controller style
(KCS) interface
Host SMM interface by means of low pin count (LPC)/keyboard controller style
(KCS) interface
Intelligent Platform Management Bus (IPMB) I2C interface
LAN interface using the IPMI-over-LAN protocols
4.6.1
Channel Management
Every messaging interface is assigned an IPMI channel ID by IPMI 2.0. Commands are
provided to configure each channel for privilege levels and access modes. The following table
shows the standard channel assignments:
Table 16. Standard Channel Assignments
Channel ID
Interface
Supports Sessions
0
Primary IPMB
No
1
LAN 1
Yes
2
LAN 2
Yes
3
LAN3 (Provided by the Intel Dedicated Server Management NIC)
Revision 1.4
1
®
Yes
41
Intel® Server Board S1600JP TPS
Channel ID
Platform Management Functional Overview
Interface
Supports Sessions
4
Reserved
Yes
5
USB
No
6
Secondary IPMB
No
7
SMM
No
8 – 0Dh
Reserved
–
0Eh
Self
2
–
0Fh
SMS/Receive Message Queue
Notes:
1.
2.
No
Optional hardware supported by the server system.
Refers to the actual channel used to send the request.
4.6.2
User Model
The BMC supports the IPMI 2.0 user model including User ID 1 support. 15 user IDs are
supported. These 15 users can be assigned to any channel. The following restrictions are
placed on user-related operations:
1. User names for User IDs 1 and 2 cannot be changed. These are always “ ” (Null/blank)
and “root” respectively.
a) A “CCh” error completion code is returned if a user attempts to modify these
names.
2. User 2 (“root”) always has the administrator privilege level.
a) A “CCh” error completion code is returned if a user attempts to modify this value.
b) Trying to set any parameter for User ID 2 (root user) with the Set User Access
command fails with a “CCh” completion code.
3. All user passwords (including passwords for 1 and 2) may be modified.
4. User IDs 3-15 may be used freely, with the condition that user names are unique.
Therefore, no other users can be named “” (Null), “root”, or any other existing user name.
Resetting a user name to a value equivalent to its current value, results in a 0xCC error code. A
list of default user values is given in the following table.
Table 17. Default User Values
Users
42
User name
Password
Status
Default Privilege
Characteristics
User 1
[Null]
[Null]
Disabled
Admin
Password can be
changed.
This user may not be
used to access the
embedded web
server.
User 2
root
superuser
Disabled
Admin
Password can be
changed.
Revision 1.4
Platform Management Functional Overview
Users
User name
Intel® Server Board S1600JP TPS
Password
Status
Default Privilege
Characteristics
User 3
test1
superuser
Disabled
Admin
User name and
password can be
changed.
User 4
test2
superuser
Disabled
Admin
User name and
password can be
changed.
User 5
test3
superuser
Disabled
Admin
User name and
password can be
changed.
User 6-15
undefined
undefined
Disabled
Admin
User name and
password can be
changed.
4.6.3
Sessions
The maximum number of IPMI-based sessions that can be supported by the BMC is returned as
the byte 3 (number of possible active sessions) of the IPMI command Get Session Info (App,
3Dh). Embedded Web Server and Media Redirection are not IPMI-based sessions. KVM is a
type of payload in a RMCP+ Session.
Table 18. Channel/Media-specific minimum number of sessions
Channels/Media type
LAN Channel1, Intel
Dedicated Server
4
Management NIC
HTTP
5
®
Session Type
IPMI Over LAN
Minimum Number of Sessions
1
Embedded Web Server
---
5
Media Redirection
---
1
KVM
2
b
3
4
6, 7
2
8, 9
2
8
2
10
Notes:
1.
Session type defined by the IPMI Spec and includes RMCP and RMCP+ sessions (including all the
payloads supported).
2. KVM is a RMCP+ Payload Type. Not an IPMI session.
3. These sessions are not defined by IPMI Specification and are not based on IPMI protocol. Counting them
as IPMI Session violates the Specification.
®
4. If Intel Dedicated Server Management NIC is not present, the minimum number of sessions still holds but
only over LAN Channel 1.
5. It is not an IPMI Channel.
6. Maximum of 15 IPMI sessions are allowed per channel that is defined.
7. IPMI-based session and counted as an IPMI Session in all calculations.
8. These sessions are not counted as IPMI sessions. (For example, Get Session Info only returns values
based on IPMI Sessions).
9. This type of Non-IPMI session can open IPMI sessions as part of a normal operation and those IPMI
sessions are counted as IPMI sessions. For example, within a Web Session, one or more IPMI Over LAN
Session are opened to Get and Set IPMI parameters. But since these IPMI sessions are not over LAN1 or
®
®
Intel Dedicated Server Management NIC, they are not counted as LAN1 or Intel Dedicated Server
Management NIC IPMI channel sessions but are counted as IPMI sessions in limit calculations.
10. It is an IPMI Over LAN RMCP+ session and is included in counts as part of the larger IPMI Over LAN
group.
Revision 1.4
43
Intel® Server Board S1600JP TPS
Platform Management Functional Overview
Note: The number of possible active session values returned by Get Session Info is the total
number of allocated memory session slots in BMC firmware for IPMI Sessions. The actual
number of IPMI sessions that can be established at any time is dependent on Channel and User
IPMI configuration parameters and in compliance with the IPMI Specification, which is always
less than the total available slots.
4.6.4
BMC LAN Channels
The BMC supports three RMII/RGMII ports that can be used for communicating with Ethernet
devices. Two ports are used for communication with the on-board NICs and one is used for
communication with an Ethernet PHY located on an optional add-in card (or equivalent on-board
circuitry).
4.6.4.1
Baseboard NICs
The specific Ethernet controller (NIC) used on a server is platform-specific but all baseboard
device options provide support for an NC-SI manageability interface. This provides a sideband
high-speed connection for manageability traffic to the BMC while still allowing for a
simultaneous host access to the OS if desired.
The Network Controller Sideband Interface (NC-SI) is a DMTF industry standard protocol for the
side band management LAN interface. This protocol provides a fast multi-drop interface for
management traffic.
The baseboard NIC(s) are connected to a single BMC RMII/RGMII port that is configured for
RMII operation. The NC-SI protocol is used for this connection and provides a 100 Mb/s fullduplex multi-drop interface which allows multiple NICs to be connected to the BMC. The
physical layer is based upon RMII, however RMII is a point-to-point bus whereas NC-SI allows
one master and up to four slaves. The logical layer (configuration commands) is incompatible
with RMII.
Multi-port baseboard NICs on some products will provide support for a dedicated management
channel that can be configured to be hidden from the host and only used by the BMC. This
mode of operation is configured through a BIOS setup option.
4.6.4.2
Dedicated Management Channel
An additional LAN channel dedicated to BMC usage and not available to host SW is supported
through an optional add-in card. There is only a PHY device present on the add-in card. The
BMC has a built-in MAC module that uses the RGMII interface to link with the card’s PHY.
Therefore, for this dedicated management interface, the PHY and MAC are located in
different devices.
The PHY on the card connects to the BMC’s other RMII/RGMII interface (that is, the one that is
not connected to the baseboard NICs). This BMC port is configured for RGMII usage.
In addition to the use of an add-in card for a dedicated management channel, on systems that
support multiple Ethernet ports on the baseboard, the system BIOS provides a setup option to
allow one of these baseboard ports to be dedicated to the BMC for manageability purposes.
When this is enabled, that port is hidden from the OS.
44
Revision 1.4
Platform Management Functional Overview
4.6.4.3
Intel® Server Board S1600JP TPS
Concurrent Server Management Use of Multiple Ethernet Controllers
Provided the HW supports a management link between the BMC and a NIC port, the BMC FW
supports concurrent OOB LAN management sessions for the following combination:
 Two on-board NIC ports
 One on-board NIC and the optional dedicated add-in management NIC
 Two on-board NICs and optional dedicated add-in management NIC
All NIC ports must be on different subnets for the above concurrent usage models.
MAC addresses are assigned for management NICs from a pool of up to three MAC addresses
allocated specifically for manageability. The total number of MAC addresses in the pool is
dependent on the product HW constraints (for example, a board with two NIC ports available for
manageability would have a MAC allocation pool of two addresses).
For these channels, support can be enabled for IPMI-over-LAN and DHCP.
For security reasons, embedded LAN channels have the following default settings:
 IP Address: Static
 All users disabled
Network failover mode must be used for IPMI capable interfaces that are on the same subnet.
Host-BMC communication over the same physical LAN connection – also known as “loopback”
– is not supported. This includes “ping” operations.
On baseboards with more than two onboard NIC ports, only the first two ports can be used as
BMC LAN channels. The remaining ports have no BMC connectivity.
Maximum bandwidth supported by BMC LAN channels are as follows:
4.6.5
BMC LAN 1 (Baseboard NIC port)
100M (10M in DC off state)
BMC LAN 2 (Baseboard NIC port)
100M (10M in DC off state)
BMC LAN 3 (Dedicated NIC)
1000M
IPv6 Support
In addition to IPv4, the Intel® Server Board S1600JP supports IPv6 for manageability channels.
Configuration of IPv6 is provided by extensions to the IPMI Set and Get LAN Configuration
Parameters commands as well as through a Web Console IPv6 configuration web page.
The BMC supports IPv4 and IPv6 simultaneously so they are both configured separately and
completely independently. For example, IPv4 can be DHCP configured while IPv6 is statically
configured or vice versa. The parameters for IPv6 are similar to the parameters for IPv4 with the
following differences:


An IPv6 address is 16 bytes versus 4 bytes for IPv4.
An IPv6 prefix is 0 to 128 bits whereas IPv4 has a 4 byte subnet mask.
Revision 1.4
45
Intel® Server Board S1600JP TPS
Platform Management Functional Overview

The IPv6 Enable parameter must be set before any IPv6 packets will be sent or received
on that channel.
 There are two variants of automatic IP Address Source configuration versus just DHCP
for IPv4.
The three possible IPv6 IP Address Sources for configuring the BMC are:

Static (Manual): The IP, Prefix, and Gateway parameters are manually configured by
the user. The BMC ignores any Router Advertisement messages received over the
network.

DHCPv6: The IP comes from running a DHCPv6 client on the BMC and receiving the IP
from a DHCPv6 server somewhere on the network. The Prefix and Gateway are
configured by Router Advertisements from the local router. The IP, Prefix, and Gateway
are read-only parameters to the BMC user in this mode.

Stateless auto-config: The Prefix and Gateway are configured by the router through
Router Advertisements. The BMC derives its IP in two parts: the upper network portion
comes from the router and the lower unique portion comes from the BMC’s channel
MAC address. The 6-byte MAC address is converted into an 8-byte value per the EUI64* standard. For example, a MAC value of 00:15:17:FE:2F:62 converts into a EUI-64
value of 215:17ff:fefe:2f62. If the BMC receives a Router Advertisement from a router at
IP 1:2:3:4: 1 with a prefix of 64, it would then generate for itself an IP of
1:2:3:4:215:17ff:fefe:2f62. The IP, Prefix, and Gateway are read-only parameters to the
BMC user in this mode.

IPv6 can be used with the BMC’s Web Console, JViewer (remote KVM and Media), and
Systems Management Architecture for Server Hardware – Command Line Protocol
(SMASH-CLP) interface (ssh). There is no standard yet on how IPMI RMCP or RMCP+
should operate over IPv6 so that is not currently supported.
4.6.5.1
LAN Failover
The BMC FW provides a LAN failover capability such that the failure of the system HW
associated with one LAN link will result in traffic being rerouted to an alternate link. This
functionality is configurable through IPMI methods as well as through the BMC’s Embedded UI,
allowing for user to specify the physical LAN links constitute the redundant network paths or
physical LAN links constitute different network paths. BMC will support “only-all-or-nothing”
approach – that is, all interfaces bonded together, or none are bonded together.
The LAN Failover feature applies only to BMC LAN traffic. It bonds all available Ethernet
devices but only one is active at a time. When enabled, if the active connection’s leash is lost,
one of the secondary connections is automatically configured so that it has the same IP address.
Traffic immediately resumes on the new active connection.
The LAN Failover enable/disable command may be sent at any time. After it has been enabled,
standard IPMI commands for setting channel configuration that specify a LAN channel other
than the first will return an error code.
4.7
System Event Log (SEL)
The BMC implements the system event log as specified in the Intelligent Platform Management
Interface Specification, Version 2.0. The SEL is accessible regardless of the system power state
through the BMC's in-band and out-of-band interfaces.
46
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
The BMC allocates 65,502 bytes (approximately 64 KB) of non-volatile storage space to store
system events. The SEL timestamps may not be in order. Up to 3,639 SEL records can be
stored at a time. Any command that results in an overflow of the SEL beyond the allocated
space is rejected with an “Out of Space” IPMI completion code (C4h).
4.7.1
Servicing Events
Events can be received while the SEL is being cleared. The BMC implements an event
message queue to avoid the loss of messages. Up to three messages can be queued before
messages are overwritten.
The BMC recognizes duplicate event messages by comparing sequence numbers and the
message source. For details, see the Intelligent Platform Management Interface Specification
Second Generation v2.0. Duplicate event messages are discarded (filtered) by the BMC after
they are read from the event message queue. The queue can contain duplicate messages.
4.7.2
SEL Entry Deletion
The BMC does not support individual SEL entry deletion. The SEL may only be cleared as
a whole.
4.7.3
SEL Erasure
SEL erasure is a background process. After initiating erasure with the Clear SEL command,
additional Clear SEL commands must be executed to get the erasure status and determine
when the SEL erasure is completed. This may take several seconds. SEL events that arrive
during the erasure process are queued until the erasure is complete and then committed to
the SEL.
SEL erasure generates an Event Logging Disabled (Log Area Reset/Cleared offset) sensor
event.
4.7.4
SEL Extension Capabilities
The BMC provides an OEM extension to all SEL entries. Each entry includes an additional 8
bytes for storing extra event data that will not fit into the original three data bytes provided by
standard IPMI SEL entries. The first extension byte is always valid for all SEL entries and
specifies the severity of the SEL event as well as the number of valid extension bytes following
the first one. That leaves up to 7 SEL extension data bytes that can be defined for each SEL
event entry.
All standard IPMI SEL commands work the same as if there were no SEL extensions.
In order to store and access the extended SEL information, five OEM commands are
implemented that closely follow the standard IPMI SEL commands but provide support for the
SEL Extension data. These OEM commands are specified in the Intel® General Application
Commands table.
4.8
Sensor Data Record (SDR) Repository
The BMC implements the sensor data record (SDR) repository as specified in the Intelligent
Platform Management Interface Specification, Version 2.0. The SDR is accessible through the
Revision 1.4
47
Intel® Server Board S1600JP TPS
Platform Management Functional Overview
BMC’s in-band and out-of-band interfaces regardless of the system power state. The BMC
allocates 65,519 bytes of non-volatile storage space for the SDR.
4.9
Field Replaceable Unit (FRU) Inventory Device
The BMC implements the interface for logical FRU inventory devices as specified in the
Intelligent Platform Management Interface Specification, Version 2.0. This functionality provides
commands used for accessing and managing the FRU inventory information. These commands
can be delivered through all interfaces.
The BMC provides FRU device command access to its own FRU device and to the FRU
devices throughout the server. The FRU device ID mapping is defined in the Platform Specific
Information. The BMC controls the mapping of the FRU device ID to the physical device.
4.10 Diagnostics and Beep Code Generation
The BMC may generate beep codes upon detection of failure conditions. Beep codes are
sounded each time the problem is discovered (for example, on each power-up attempt), but are
not sounded continuously. Common supported codes are listed in Table 17.
Additional platform-specific beep codes can be found in the appropriate Platform Specific
Information. Each digit in the code is represented by a sequence of beeps whose count is equal
to the digit.
Table 19. BMC Beep Codes
Code
48
Reason for Beep
Associated Sensors
Supported
1-5-2-1
No CPUs installed
CPU Missing Sensor
Yes
1-5-2-4
MSID Mismatch
MSID Mismatch Sensor
Yes
1-5-4-2
Power fault: DC power is unexpectedly
lost (power good dropout)
Power unit – power unit failure
offset
Yes
1-5-4-4
Power control fault (power good assertion
timeout)
Power unit – soft power control
failure offset
Yes
1-5-1-2
VR Watchdog Timer sensor assertion
VR Watchdog Timer
1-5-1-4
The system does not power on or
unexpectedly powers off and a power
supply unit (PSU) is present that is an
incompatible model with one or more
other PSUs in the system
PSU status
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
4.11 Diagnostics Interrupt (NMI)
The BMC generates an NMI pulse under certain conditions. The BMC-generated NMI pulse
duration is at least 30ms. Once an NMI has been generated by the BMC, the BMC does not
generate another NMI until the system has been reset or powered down.
The following actions cause the BMC to generate an NMI pulse:
a. Receiving a Chassis Control command to pulse the diagnostic interrupt. This command
does not cause an event to be logged in the SEL.
b. Detecting that the front panel diagnostic interrupt button has been pressed.
c. Watchdog timer pre-timeout expiration with NMI/diagnostic interrupt pre-timeout action
enabled.
The following table shows behavior regarding NMI signal generation and event logging by the
BMC.
Table 20. NMI Signal Generation and Event Logging
Causal Event
NMI (IA-32 Only)
Signal Generation
Front Panel Diagnostic Interrupt Sensor
Event Logging Support
Chassis Control command (pulse diagnostic
interrupt)
X
–
Front panel diagnostic interrupt button pressed
X
X
Watchdog Timer pre-timeout expiration with
NMI/diagnostic interrupt action
X
–
4.12 BMC Basic and Advanced Management Features
The Intel® Server Board S1600JP product includes support for an upgrade module to support
the advanced server management functionality.
Table 21. Basic and Advanced Management Features
Feature
Revision 1.4
Basic*
Advanced**
IPMI 2.0 Feature Support
X
X
In-circuit BMC Firmware Update
X
X
FRB 2
X
X
Chassis Intrusion Detection
X
X
Fan Redundancy Monitoring
X
X
Hot-Swap Fan Support
X
X
Acoustic Management
X
X
Diagnostic Beep Code Support
X
X
Power State Retention
X
X
ARP/DHCP Support
X
X
49
Intel® Server Board S1600JP TPS
Platform Management Functional Overview
Feature
Basic*
Advanced**
PECI Thermal Management Support
X
X
E-mail Alerting
X
X
Embedded Web Server
X
X
SSH Support
X
Integrated KVM
X
X
Integrated Remote Media Redirection
X
Local Directory Access Protocol (LDAP)
X
X
Intel Intelligent Power Node Manager
Support***
X
X
SMASH CLP
X
X
®
* Basic management features provided by Integrated BMC.
®
**Advanced management features available with optional Intel Remote Management Module 4 Lite.
®
***Intel Intelligent Power Node Manager Support requires PMBus*-compliant power supply.
4.12.1
Enabling Advanced Manageability Features
The Advanced management features are to be delivered as part of the BMC FW image. The
BMC’s baseboard SPI flash contains code/data for both the Basic and Advanced features. An
optional module Intel® RMM4 Lite is used as the activation mechanism. When the BMC FW
initializes, it attempts to access the Intel® RMM4 lite. If the attempt to access Intel® RMM4 Lite is
successful, then the BMC activates the advanced features.
Advanced manageability features are supported over all NIC ports enabled for server
manageability. This includes baseboard NICs as well as the LAN channel provided by the
optional Dedicated NIC add-in card.
Table 22. Management features and Benefits
Manageability Hardware
Benefits
®
Comprehensive IPMI based base manageability
features.
®
No dedicated NIC for management.
Enables KVM and media redirection through onboard
NIC.
®
Dedicated NIC for management traffic. Higher
bandwidth connectivity for KVM and media.
Redirection with 1Gbe NIC.
Intel Integrated BMC
Intel Remote Management Module4 – Lite
Package contains one module –

Key for advance Manageability features
Intel Remote Management4 Module
Package includes two modules –

Key for advance features

Dedicated NIC (1Gbe) for management
4.12.1.1
Keyboard, Video, and Mouse (KVM) Redirection
The BMC firmware supports keyboard, video, and mouse redirection (KVM) over LAN. This
feature is available remotely from the embedded web server as a Java* applet. This feature is
enabled when the Intel® RMM4 Lite is present. The client system must have a Java* Runtime
Environment (JRE) version 5.0 or later to run the KVM or media redirection applets.
50
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
The Integrated BMC supports an embedded KVM application (Remote Console) that can be
launched from the embedded web server from a remote console. USB1.1 or USB 2.0 based
mouse and keyboard redirection are supported. It is also possible to use the KVM-redirection
(KVM-r) session concurrently with media-redirection (media-r). This feature allows a user to
interactively use the keyboard, video, and mouse (KVM) functions of the remote server as if the
user were physically at the managed server.
The KVM-redirection feature automatically senses video resolution for best possible screen
capture and provides high-performance mouse tracking and synchronization. It allows remote
viewing and configuration in pre-boot POST and BIOS setup, once BIOS has initialized video.
Other attributes of this feature include:

Encryption of the redirected screen, keyboard, video, and mouse

Compression of the redirected screen
4.12.1.2
Remote Console
The Remote Console is the redirected screen, keyboard, video, and mouse of the remote host
system. To use the Remote Console window of your managed host system, the browser must
include a Java* Runtime Environment plug-in. If the browser has no Java* support, such as with
a small handheld device, the user can maintain the remote host system using the administration
forms displayed by the browser.
The Remote Console window is a Java* Applet that establishes TCP connections to the
Integrated BMC. The protocol that is run over these connections is a unique KVM protocol and
not HTTP or HTTPS. This protocol uses ports #7578 for KVM, #5120 for CDROM media
redirection, and #5123 for Floppy/USB media redirection (both supporting encryption).
4.12.1.3
Performance
The remote display accurately represents the local display. The feature adapts to changes to the
video resolution of the local display and continues to work smoothly when the system transitions
from graphics to text or vice-versa. The responsiveness may be slightly delayed depending on
the bandwidth and latency of the network.
Enabling KVM and/or media encryption will degrade performance. Enabling video compression
provides the fastest response while disabling compression provides better video quality.
For the best possible KVM performance, a 2Mb/sec link or higher is recommended.
The redirection of KVM over IP is performed in parallel with the local KVM without affecting the
local KVM operation.
4.12.1.4
Security
The KVM redirection feature supports multiple encryption algorithms, including RC4 and AES.
The actual algorithm that is used is negotiated with the client based on the client’s capabilities.
4.12.1.5
Availability
The remote KVM session is available even when the server is powered-off (in stand-by mode).
No re-start of the remote KVM session shall be required during a server reset or power on/off.
Revision 1.4
51
Intel® Server Board S1600JP TPS
Platform Management Functional Overview
An Integrated BMC reset (for example, due to an Integrated BMC Watchdog initiated reset or
Integrated BMC reset after Integrated BMC firmware update) will require the session to be reestablished.
KVM sessions persist across system reset, but not across an AC power loss.
4.12.1.6
Timeout
The remote KVM session will automatically timeout after a configurable amount of time (30
minutes is the default).
The default inactivity timeout is 30 minutes, but may be changed through the embedded web
server. Remote KVM activation does not disable the local system keyboard, video, or mouse.
Remote KVM is not deactivated by local system input, unless the feature is disabled locally.
4.12.1.7
Usage
As the server is powered up, the remote KVM session displays the complete BIOS boot process.
The user is able to interact with BIOS setup, change and save settings as well as enter and
interact with option ROM configuration screens.
At least two concurrent remote KVM sessions are supported. It is possible for at least two
different users to connect to the same server and start remote KVM sessions.
4.12.2
Media Redirection
The embedded web server provides a Java* applet to enable remote media redirection. This
may be used in conjunction with the remote KVM feature, or as a standalone applet.
The media redirection feature is intended to allow system administrators or users to mount a
remote USB HDD or USB CD-ROM, floppy drive, or a USB flash disk as a remote device to the
server. Once mounted, the remote device appears just like a local device to the server, allowing
system administrators or users to install software (including operating systems), copy files,
update BIOS, and so on, or boot the server from this device.
The following capabilities are supported:
52

The operation of remotely mounted devices is independent of the local devices on the
server. Both remote and local devices are useable in parallel.

It is possible to boot all supported operating systems from the remotely mounted device
and to boot from disk IMAGE (*.IMG) and CD-ROM or DVD-ROM ISO files. See the
tested/supported Operating System List for more information.

Media redirection shall support redirection for a minimum of two virtual devices
concurrently with any combination of devices. As an example, a user could redirect two
CD or two USB devices.

The media redirection feature supports multiple encryption algorithms, including RC4
and AES. The actual algorithm that is used is negotiated with the client based on the
client’s capabilities.

A remote media session is maintained even when the server is powered-off (in standby
mode). No restart of the remote media session is required during a server reset or power
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
on/off. An Integrated BMC reset (for example, due to an Integrated BMC reset after
Integrated BMC firmware update) will require the session to be re-established.

The mounted device is visible to (and useable by) the managed system’s OS and BIOS
in both pre-boot and post-boot states.

The mounted device shows up in the BIOS boot order and it is possible to change the
BIOS boot order to boot from this remote device.

It is possible to install an operating system on a bare metal server (no OS present) using
the remotely mounted device. This may also require the use of KVM-r to configure the
OS during install.

USB storage devices will appear as floppy disks over media redirection. This allows for
the installation of device drivers during OS installation.

If either a virtual floppy device is remotely attached during system boot, the virtual floppy
is presented as a bootable device. It is not possible to present only a single-mounted
device type to the system BIOS.
4.12.2.1
Availability
The default inactivity timeout is 30 minutes and is not user-configurable.
Media redirection sessions persist across system reset but not across an AC power loss or
BMC reset.
4.12.2.2
Network Port Usage
The KVM and media redirection features use the following ports:

5120 – CD Redirection

5123 – FD Redirection

5124 – CD Redirection (Secure)

5127 – FD Redirection (Secure)

7578 – Video Redirection

7582 – Video Redirection (Secure)
4.12.3
Embedded Web server
Integrated BMC Base manageability provides an embedded web server and an OEMcustomizable web GUI which exposes the manageability features of the Integrated BMC base
feature set. It is supported over all on-board NICs that have management connectivity to the
Integrated BMC as well as an optional dedicated add-in management NIC. At least two
concurrent web sessions from up to two different users is supported. The embedded web user
interface shall support the following client web browsers:

Microsoft Internet Explorer 7.0*

Microsoft Internet Explorer 8.0*

Microsoft Internet Explorer 9.0*

Mozilla Firefox 3.0*

Mozilla Firefox 3.5*
Revision 1.4
53
Intel® Server Board S1600JP TPS

Platform Management Functional Overview
Mozilla Firefox 3.6*
The embedded web user interface supports strong security (authentication, encryption, and
firewall support) since it enables remote server configuration and control. The user interface
presented by the embedded web user interface shall authenticate the user before allowing a
web session to be initiated. Encryption using 128-bit SSL is supported. User authentication is
based on user id and password.
The GUI presented by the embedded web server authenticates the user before allowing a web
session to be initiated. It presents all functions to all users but grays-out those functions that the
user does not have privilege to execute. (For example, if a user does not have privilege to
power control, then the item shall be displayed in gray-out font in that user’s UI display). The
web GUI also provides a launch point for some of the advanced features, such as KVM and
media redirection. These features are grayed out in the GUI unless the system has been
updated to support these advanced features.
A partial list of additional features supported by the web GUI includes:

Present all the Basic features to the users.

Power on/off/reset the server and view current power state.

Virtual front panel display and overall system health.

Provide embedded firmware version information.

Configuration of various IPMI parameters (LAN parameters, users, passwords, and so
on.)

Configuration of alerting (SNMP and SMTP).

Display system asset information for the product, board, and chassis.

Display of BMC-owned sensors (name, status, current reading, and enabled thresholds),
including color-code status of sensors.

Automatic refresh of sensor data with a configurable refresh rate.

On-line help.

Display/clear SEL (display is in easily understandable human readable format).

Supports major industry-standard browsers (Internet Explorer and Mozilla Firefox*).

Automatically logs out after user-configurable inactivity period.

The GUI session automatically times-out after a user-configurable inactivity period. By
default, this inactivity period is 30 minutes.

Embedded Platform Debug feature - Allow the user to initiate a “diagnostic dump” to a
file that can be sent to Intel® for debug purposes.

Display of power statistics (current, average, minimum, and maximum) consumed by
the server.
4.12.4
Data Center Management Interface (DCMI)
The DCMI Specification is an emerging standard that is targeted to provide a simplified
management interface for Internet Portal Data Center (IPDC) customers. It is expected to
become a requirement for server platforms which are targeted for IPDCs. DCMI is an IPMI54
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
based standard that builds upon a set of required IPMI standard commands by adding a set of
DCMI-specific IPMI OEM commands.
4.12.5
Lightweight Directory Authentication Protocol (LDAP)
The Lightweight Directory Access Protocol (LDAP) is an application protocol supported by the
Integrated BMC for the purpose of authentication and authorization. The Integrated BMC user
connects with an LDAP server for login authentication. This is only supported for non-IPMI
logins including the embedded web UI and SM-CLP. IPMI users/passwords and sessions are
not supported over LDAP.
LDAP can be configured (IP address of LDAP server, port, and so on.) through the Integrated
BMC’s Embedded Web UI. LDAP authentication and authorization is supported over the any
NIC configured for system management. The BMC uses a standard Open LDAP implementation
for Linux*.
4.12.6
Platform/Chassis Management
Within an IPMI 2.0 framework, the BMC Firmware provides functionality to support management
and control of several aspects of the platform operation. This includes:

Front Panel Support (for example, secure lock out of power and reset buttons and
System Status LED control)

Hardware/Sensor Monitoring (for example, system voltages, thermal sensors, fans,
power supplies, and so on)

Power/Reset Control and Monitoring (for example, local and remote power/reset
control and power restore policy)

Hardware and Manufacturing Test Features

Asset Inventory and System Identification (for example, system GUID and FRU
management)

Thermal and Acoustics Management – The BMC firmware provides a comprehensive
set of fan control capabilities utilizing various system thermal sensors (for example, CPU,
DIMMs, and front panel thermal sensor). Additionally, the BMC participates in the
memory CLTT by pushing dim thermal data to the iMC in the CPU.

Power Management (Node Manager) Support – BMC firmware provides an external
(LAN) interface for a remote management console to communicate with the ME’s Node
Manager Functionality.
4.12.7
Thermal Control
The system shall support thermal management through open loop throttling (OLTT) or static
closed loop throttling (CLTT) of system memory based on availability of valid temperature
sensors on the installed memory DIMMs. The Integrated Memory Controller (IMC) dynamically
changes throttling levels to cap throttling based on memory and system thermal conditions as
determined by the system and DIMM power and thermal parameters. CLTT on mixed-mode
DIMM populations is not supported (that is, some installed DIMMs have valid temp sensors and
some do not). The Integrated BMC fan speed control functionality is related to the memory
throttling mechanism used.
Revision 1.4
55
Intel® Server Board S1600JP TPS
Platform Management Functional Overview
The following terminology is used for the various memory throttling options:

Static Open Loop Thermal Throttling (Static-OLTT): OLTT control registers are
configured by BIOS MRC remain fixed after post. The system does not change any of
the throttling control registers in the embedded memory controller during runtime.

Static Closed Loop Thermal Throttling (Static-CLTT): CLTT control registers are
configured by BIOS MRC during POST. The memory throttling is run as a closed-loop
system with the DIMM temperature sensors as the control input. Otherwise, the system
does not change any of the throttling control registers in the embedded memory
controller during runtime.

Dynamic Open Loop Thermal Throttling (Dynamic-OLTT): OLTT control registers are
configured by BIOS MRC during POST. Adjustments are made to the throttling during
runtime based on changes in system cooling (fan speed).

Dynamic Closed Loop Thermal Throttling (Dynamic-CLTT): CLTT control registers
are configured by BIOS MRC during POST. The memory throttling is run as a closedloop system with the DIMM temperature sensors as the control input. Adjustments are
made to the throttling during runtime based on changes in system cooling (fan speed).
4.12.7.1
Fan Speed Control Profiles
BIOS and BMC software work cooperatively to implement system thermal management support.
During normal system operation, the BMC will retrieve information from the BIOS and monitor
several platform thermal sensors to determine the required fan speeds.
In order to provide the proper fan speed control for a given system configuration, the BMC must
have the appropriate platform data programmed. Platform configuration data is programmed
using the FRUSDR utility during the system integration process and by System BIOS during
run time.
Table 23. Fab Profile Mapping
Type
4.12.7.2
Profile
Details
OLTT
0
Acoustic, 300M altitude
OLTT
1
Performance, 300M altitude
OLTT
2
Acoustic, 900M altitude
OLTT
3
Performance, 900M altitude
OLTT
4
Acoustic, 1500M altitude
OLTT
5
Performance, 1500M altitude
OLTT
6
Acoustic, 3000M altitude
OLTT
7
Performance, 3000M altitude
CLTT
0
300M altitude
CLTT
2
900M altitude
CLTT
4
1500M altitude
CLTT
6
3000M altitude
System Configuration using FRUSDR Utility
The Field Replaceable Unit and Sensor Data Record Update Utility (FRUSDR utility) is a
program used to write platform-specific configuration data to NVRAM on the server board. It
56
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
allows the user to select which supported chassis (Intel® or Non-Intel®) and platform chassis
configuration is used. Based on the input provided, the FRUSDR writes sensor data specific to
the configuration to NVRAM for the BMC controller to read each time the system is powered on.
4.13 Intel® Intelligent Power Node Manager
4.13.1
Overview
Power management deals with requirements to manage processor power consumption and
manage power at the platform level to meet critical business needs. Node Manager (NM) is a
platform resident technology that enforces power capping and thermal-triggered power capping
policies for the platform. These policies are applied by exploiting subsystem knobs (such as
processor P and T states) that can be used to control power consumption. NM enables data
center power management by exposing an external interface to management software through
which platform policies can be specified. It also implements specific data center power
management usage models such as power limiting and thermal monitoring.
Note: Support for NM is product-specific. This section details how NM would be supported on
products that provide this capability.
The NM feature is implemented by a complementary architecture utilizing the ME, BMC, BIOS,
and an ACPI-compliant OS. The ME provides the NM policy engine and power control/limiting
functions (referred to as Node Manager or NM) while the BMC provides the external LAN link by
which external management software can interact with the feature. The BIOS provides system
power information utilized by the NM algorithms and also exports ASL code used by OSPM for
negotiating processor P and T state changes for power limiting. PMBus*-compliant power
supplies provide the capability to monitoring input power consumption, which is necessary to
support NM.
The NM architecture applicable to this generation of servers is defined by the NPTM
Architecture Specification v2.0. NPTM is an evolving technology that is expected to continue to
add new capabilities that will be defined in subsequent versions of the specification. The ME NM
implements the NPTM policy engine and control/monitoring algorithms defined in the
NPTM specification.
4.13.2
Features
NM provides feature support for policy management, monitoring and querying, alerts and
notifications, and an external interface protocol. The policy management features implement
specific IT goals that can be specified as policy directives for NM. Monitoring and querying
features enable tracking of power consumption. Alerts and notifications provide the foundation
for automation of power management in the data center management stack. The external
interface specifies the protocols that must be supported in this version of NM.
The role of BMC in Node Manager will include:

External communication links

Command passing through BMC

Alerting

BIOS-BMC-ME communication
Revision 1.4
57
Intel® Server Board S1600JP TPS
Platform Management Functional Overview
4.14 Management Engine (ME)
4.14.1
Overview
®
The Intel Server Platform Services (SPS) is a set of manageability services provided by the
firmware executing on an embedded ARC controller within the IOH. This management controller
is also commonly referred to as the Management Engine (ME). The functionality provided by the
SPS firmware is different from Intel® Active Management Technology (Intel® AMT or AT)
provided by the ME on client platforms.
Server Platform Services (SPS) are value-added platform management options that enhance
the value of Intel® platforms and their component ingredients (CPUs, chipsets, and I/O
components). Each service is designed to function independently wherever possible, or grouped
together with one or more features in flexible combinations to allow OEMs to differentiate
platforms.
4.14.2
BMC – Management Engine (ME) Distributed Model
The Intel® Server Board S1600JP covered in this specification will require Node Manager 2.0
(NM2.0) support. The following management architecture would need to be supported on the
baseboard to meet product and validation requirements. The NM 2.0 functionality is provided by
the Intel® C600 PCH Management Engine (ME).
The server management architecture is a partitioned model which places the Management
Engine, which is an embedded controller in the Intel® C600 PCH, in between the BMC and the
processors. In this architecture, the PCH Management Engine is the owner of the PECI 3.0 bus
and the Emulex* Pilot III BMC communicates with the ME through a SMBus* connection
(SMLINK 0.) The ME provides PECI proxy support that allows the ServerEngines* Pilot III BMC
firmware to access processor functions available on the PECI bus.
The primary function of ME is to implement the NM 2.0 feature set. In this architectural model,
the Emulex* Pilot III BMC provides the external (LAN) interface to ME in the form of IPMI
bridging. A remote Node Manager application would establish a management session with the
Emulex* Pilot III BMC which in turn would bridge IPMI commands through the secondary IPMB
to the ME. In this scenario, the Emulex* Pilot III BMC simply acts as a proxy for this
communication pipe. The ME may also generate alerts to the Emulex* Pilot III BMC, which may
log these into the system SEL and/or output them to the remote application in the form of IPMI
LAN alerts.
The Emulex* Pilot III BMC needs access to various system registers in the processor core
silicon and integrated memory controller subsystem. Examples include Processor core and
Memory DIMMs temperature information. The Emulex* Pilot III BMC requires this information as
input into its fan speed control algorithms. The Emulex* Pilot III BMC accesses these registers
through the secondary IPMB bus connection to ME. Depending on the particular data or register
access needed, this is done using either the ME’s PECI proxy functionality or through an
abstracted data construct provided by the ME.
Also in this architecture, both the Emulex* Pilot III BMC and the ME are connected to the
system power supplies through a common PMBus* (SMBUS* physical) connection (SMLINK 1.)
The ME accesses the system power supplies in support of various NM 2.0 features. The
Emulex* Pilot III BMC monitors the power supplies in support of various power-related telemetry
and status information that is exposed as IPMI sensors.
58
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
Figure 18. Management Engine Distribution Model
4.14.3
ME System Management Bus (SMBus*) Interface

The ME uses the SMLink0 on the SSB in multi-master mode as a dedicated bus for
communication with the BMC using the IPMB protocol. The EPSD BMC FW considers
this a secondary IPMB bus and runs at 400 kHz.

The ME uses the SMLink1 on the SSB in multi-master mode bus for communication with
PMBus* devices in the power supplies for support of various NM-related features. This
bus is shared with the BMC, which polls these PMBus* power supplies for sensor
monitoring purposes (for example, power supply status, input power, and so on.). This
bus runs at 100 KHz.

The Management Engine has access to the “Host SMBus*”.
4.14.4
BMC - Management Engine Interaction
Management Engine-Integrated BMC interactions include the following:

Integrated BMC stores sensor data records for ME-owned sensors.

Integrated BMC participates in ME firmware update.

Integrated BMC initializes ME-owned sensors based on SDRs.

Integrated BMC receives platform event messages sent by the ME.

Integrated BMC notifies ME of POST completion.
Revision 1.4
59
Intel® Server Board S1600JP TPS

Platform Management Functional Overview
BMC may be queried by the ME for inlet temperature readings.
4.14.5
ME Power and Firmware Startup
®
On Intel Server Board S1600JP, the ME is on standby power. The ME FW will begin its startup
sequence at the same time that the BMC FW is booting. As the BMC FW is booting to a Linux*
kernel and the ME FW uses an RTOS, the ME FW should always complete its basic
initialization before the BMC. The ME FW can be configured to send a notification message to
the BMC. After this point, the ME FW is ready to process any command requests from
the BMC.
In S0/S1 power states, all ME FW functionality is supported. Some features, such as power
limiting, are not supported in S3/S4/S5 power states. Refer to ME FW documentation for details
on what is not supported while in the S3/S4/S5 states.
The ME FW uses a single operational image with a limited-functionality recovery image. In order
to upgrade an operational image, a boot to recovery image must be performed. The ME FW
does not support an IPMI update mechanism except for the case that the system is configured
with a dual-ME (redundant) image. In order to conserve flash space, which the ME FW shares
with BIOS, EPSD systems only support a single ME image. For this case, ME update is only
supported by means of BIOS performing a direct update of the flash component. The recovery
image only provides the basic functionality that is required to perform the update; therefore
other ME FW features are not functional therefore when the update is in progress.
4.14.6
SmaRT/CLST
The power supply optimization provided by SmaRT/CLST relies on a platform HW capability as
well as ME FW support. When a PMBus*-compliant power supply detects insufficient input
voltage, an over current condition, or an over-temperature condition, it will assert the SMBAlert#
signal on the power supply SMBus* (also known as the PMBus*). Through the use of external
gates, this results in a momentary assertion of the PROCHOT# and MEMHOT# signals to the
processors, thereby throttling the processors and memory. The ME FW also sees the
SMBAlert# assertion, queries the power supplies to determine the condition causing the
assertion, and applies an algorithm to either release or prolong the throttling, based on the
situation.
System power control modes include:

SmaRT: Low AC input voltage event; results in a onetime momentary throttle for
each event to the maximum throttle state.

Electrical Protection CLST: High output energy event; results in a throttling hiccup
mode with fixed maximum throttle time and a fix throttle release ramp time.

Thermal Protection CLST: High power supply thermal event; results in a throttling
hiccup mode with fixed maximum throttle time and a fix throttle release ramp time.
When the SMBAlert# signal is asserted, the fans will be gated by HW for a short period
(~100ms) to reduce overall power consumption. It is expected that the interruption to the fans
will be of short enough duration to avoid false lower threshold crossings for the fan tach sensors;
however, this may need to be comprehended by the fan monitoring FW if it does have this sideeffect.
60
Revision 1.4
Platform Management Functional Overview
Intel® Server Board S1600JP TPS
4.15 Other Platform Management
The platform supports the following sleep states, S1 and S5. Within S0, the platform supports
additional lower power states, such as C1e and C6, for the CPU.
4.15.1
4.15.2
Wake On LAN (WOL)

Wake On LAN (WOL) is supported on both LAN ports and IOM LAN modules for all
supported Sleep states.

Wake on Ring is supported on the external Serial port only for all supported Sleep
states.

Wake on USB is supported on the rear and front panel USB ports for S1 only.

Wake on RTC is supported for all supported Sleep states.

Wake IPMI command is supported (BMC function no additional hardware
requirement) for all supported Sleep states.
PCI Express* Power management
L0 and L3 power management states are supported on all PCI Express* slots and embedded
end points.
4.15.3
PMBus*
Power supplies that have PMBus* 1.1 are supported and required to support Intel® Dynamic
Power Node Manager. Intel® Server Board S1600JP supports the features of Intel® Dynamic
Power Node Manager version 1.5 except the inlet temperature sensor.
Revision 1.4
61
BIOS Setup Interface
Intel® Server Board S1600JP TPS
5.
BIOS Setup Interface
5.1
HotKeys Supported During POST
Certain “HotKeys” are recognized during POST. A HotKey is a key or a key combination that is
recognized as an unprompted command input, that is, the operator is not prompted to press the
HotKey and typically the HotKey will be recognized even while other processing is in progress.
The Intel® Server Board S1600JP Family BIOS recognizes a number of HotKeys during POST.
After the OS is booted, HotKeys are the responsibility of the OS and the OS defines its own set
of recognized HotKeys.
Following are the POST HotKeys, with their functions:
Table 24. POST HotKeys Recognized
HotKey Combination
5.2
Function
<F2>
Enter Setup
<F6>
Pop up BIOS Boot Menu
<F12>
Network boot
POST Logo/Diagnostic Screen
The logo/Diagnostic Screen displays in one of two forms:

If Quiet Boot is enabled in the BIOS setup, a logo splash screen displays. By default,
Quiet Boot is enabled in the BIOS setup. If the logo displays during POST, press <Esc>
to hide the logo and display the diagnostic screen.

If a logo is not present in the flash ROM or if Quiet Boot is disabled in the system
configuration, the POST Diagnostic Screen is displayed with a summary of system
configuration information.
The diagnostic screen displays the following information:
62

“Copyright <year> Intel Corporation”

AMI Copyright statement

BIOS version (ID)

BMC firmware version

SDR version

ME firmware version

Platform ID

System memory detected (total size of all installed DDRIII DIMMs)

Current memory speed (currently configured memory operating frequency)

Processor information (Intel® Brand String identifying type of processor and nominal
operating frequency, and number of physical processors identified).

Keyboards detected, if any attached
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface

Mouse devices detected, if any attached

Instructions showing HotKeys for going to Setup, going to popup Boot Menu, starting
Network Boot
5.3
BIOS Boot Pop-up Menu
The BIOS Boot Specification (BBS) provides a Boot Pop-up menu that can be invoked by
pressing the <F6> key during POST. The BBS Pop-up menu displays all available boot devices.
The boot order in the pop-up menu is not the same as the boot order in the BIOS setup. The
pop-up menu simply lists all of the available devices from which the system can be booted, and
allows a manual selection of the desired boot device.
When an Administrator password is installed in Setup, the Administrator password will be
required in order to access the Boot Pop-up menu using the <F6> key. If a User password is
entered, the Boot Pop-up menu will not even appear – the user will be taken directly to the Boot
Manager in the Setup, where the User password allows only booting in the order previously
defined by the Administrator.
5.4
BIOS Setup Utility
The BIOS Setup utility is a text-based utility that allows the user to configure the system and
view current settings and environment information for the platform devices. The Setup utility
controls the platform's built-in devices, the boot manager, and error manager.
The BIOS Setup interface consists of a number of pages or screens. Each page contains
information or links to other pages. The advanced tab in Setup displays a list of general
categories as links. These links lead to pages containing a specific category’s configuration.
The following sections describe the look and behavior for the platform setup.
5.4.1
BIOS Setup Operation
The BIOS Setup Utility has the following features:

Localization – The Intel® Server Board BIOS is only available in English. However, BIOS
Setup uses the Unicode standard and is capable of displaying data and input in Setup
fields in all languages currently included in the Unicode standard.

Console Redirection – BIOS Setup is functional through Console Redirection over
various terminal emulation standards. This may limit some functionality for compatibility,
for example, usage of colors or some keys or key sequences or support of
pointing devices.

Setup screens are designed to be displayable in an 80-character x 24-line format in
order to work with Console Redirection, although that screen layout should display
correctly on any format with longer lines or more lines on the screen.

Password protection – BIOS Setup may be protected from unauthorized changes by
setting an Administrative Password in the Security screen. When an Administrative
Password has been set, all selection and data entry fields in Setup (except System Time
and Date) are grayed out and cannot be changed unless the Administrative Password
has been entered.
Revision 1.4
63
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Note: If an Administrative Password has not been set, anyone who boots the system to Setup
has access to all selection and data entry fields in Setup and can change any of them.
5.4.1.1
Setup Page Layout
The Setup page layout is sectioned into functional areas. Each occupies a specific area of the
screen and has dedicated functionality. The following table lists and describes each
functional area.
The Setup page is designed to a format of 80 x 24 (24 lines of 80 characters each). The typical
display screen in a Legacy mode or in a terminal emulator mode is actually 80 characters by 25
lines, but with “line wrap” enabled (which it usually is) the 25th line cannot be used with the
Setup page.
Table 25. BIOS Setup Page Layout
Functional Area
Description
Title (Tab) Bar
The Title Bar is located at the top of the screen and displays “Tabs” with the titles of
the top-level pages, or screens that can be selected. Using the left and right arrow
keys moves from page to page through the Tabs.
When there are more Tabs than can be displayed on the Title (Tab) Bar, they will
scroll off to the left or right of the screen and temporarily disappear from the visible
Title Bar. Using the arrow keys will scroll them back onto the visible Title Bar. When
the arrow keys reach either end of the Title Bar, they will “wrap around” to the other
end of the Title Bar.
For multi-level hierarchies, this shows only the top-level page above the page which
the user is currently viewing. The Page Title gives further information.
Page Title
In a multi-level hierarchy of pages beneath one of the top-level Tabs, the Page Title
identifying the specific page which the user is viewing is located in the upper left
corner of the page. Using the <ESC> (Escape) key will return the user to the higher
level in the hierarchy, until the top-level Tab page is reached.
Setup Item List
The Setup Item List is a set of control entries and informational items. The list is
displayed in two columns. For each item in the list:

The left column of the list contains Prompt String (or Label String), a character
string which identifies the item. The Prompt String may be up to 34 characters
long in the 80 x 24 page format.

The right column contains a data field which may be an informational data
display, a data input field, or a multiple choice field. Data input or multiplechoice fields are demarcated by square brackets (“[....]”). This field may be up
to 90 characters long, but only the first 22 characters can be displayed on the
80 x 24 page (24 characters for an informational display-only field).
The operator navigates up and down the right hand column through the available
input or choice fields.
A Setup Item may also represent a selection to open a new screen with a further
group of options for specific functionality. In this case, the operator navigates to the
desired selection and presses <Enter> to go to the new screen.
Item-Specific Help Area
The Item-specific Help Area is located on the right side of the screen and contains
Help Text specific to the highlighted Setup Item. Help information may include the
meaning and usage of the item, allowable values, effects of the options, and so on.
The Help Area is a 29 character by 11 line section of the 80 x 24 page. The Help
Text may have explicit line-breaks within it. When the text is longer than 29
characters, it is also broken to a new line, dividing the text at the last space
th
(blank) character before the 29 character. An unbroken string of more than 29
th
characters will be arbitrarily wrapped to a new line after the 29 character. Text
th
that extends beyond the end of the 11 line will not be displayed.
64
Revision 1.4
Intel® Server Board S1600JP TPS
Functional Area
Description
Keyboard Command Area
5.4.1.2
BIOS Setup Interface
The Keyboard Command Area is located at the bottom right of the screen and
continuously displays help for keyboard special keys and navigation keys.
Entering BIOS Setup
To enter the BIOS Setup using a keyboard (or emulated keyboard), press the <F2> function key
during boot time when the OEM or Intel® logo is displayed. The following message is displayed
on the diagnostics screen and under the Quiet Boot logo screen:
Press <F2> to enter setup
When the Setup Utility is entered, the Main screen is displayed. However, serious errors cause
the system to display the Error Manager screen instead of the Main screen.
It is also possible to cause a boot to Setup using an IPMI 2.0 command “Get/Set System Boot
Options”. For details on that capability, see the explanation in the IPMI description.
5.4.1.3
Setup Navigation Keyboard Commands
The bottom right portion of the Setup screen provides a list of commands that are used to
navigate through the Setup utility. These commands are displayed at all times.
Each Setup menu page contains a number of features. Each feature is associated with a value
field, except those used for informative purposes. Each value field contains configurable
parameters. Depending on the security option chosen and in effect by the password, a menu
feature’s value may or may not be changed. If a value cannot be changed, its field is made
inaccessible and appears grayed out.
Table 26. BIOS Setup: Keyboard Command Bar
Key
Option
<Enter>
Execute
Command
The <Enter> key is used to activate submenus when the selected feature is a
submenu, or to display a pick list if a selected option has a value field, or to select a
subfield for multi-valued features like time and date. If a pick list is displayed, the
<Enter> key selects the currently highlighted item, undoes the pick list, and returns
the focus to the parent menu.
<Esc>
Exit
The <Esc> key provides a mechanism for backing out of any field. When the
<Esc> key is pressed while editing any field or selecting features of a menu, the
parent menu is re-entered.
When the <Esc> key is pressed in any submenu, the parent menu is re-entered.
When the <Esc> key is pressed in any major menu, the exit confirmation window is
displayed and the user is asked whether changes can be discarded. If “No” is
selected and the <Enter> key is pressed, or if the <Esc> key is pressed, the user
is returned to where they were before <Esc> was pressed, without affecting any
existing settings. If “Yes” is selected and the <Enter> key is pressed, the setup is
exited and the BIOS returns to the main System Options Menu screen.

Select Item
The up arrow is used to select the previous value in a pick list, or the previous
option in a menu item's option list. The selected item must then be activated by
pressing the <Enter> key.

Select Item
The down arrow is used to select the next value in a menu item’s option list, or a
value field’s pick list. The selected item must then be activated by pressing the
<Enter> key.

Select Menu
The left and right arrow keys are used to move between the major menu pages.
The keys have no effect if a sub-menu or pick list is displayed.
Revision 1.4
Description
65
BIOS Setup Interface
Key
Option
Intel® Server Board S1600JP TPS
Description
<Tab>
Select Field
The <Tab> key is used to move between fields. For example, <Tab> can be used
to move from hours to minutes in the time item in the main menu.
-
Change Value
The minus key on the keypad is used to change the value of the current item to the
previous value. This key scrolls through the values in the associated pick list
without displaying the full list.
+
Change Value
The plus key on the keypad is used to change the value of the current menu item
to the next value. This key scrolls through the values in the associated pick list
without displaying the full list. On 106-key Japanese keyboards, the plus key has a
different scan code than the plus key on the other keyboards, but will have the
same effect.
<F9>
Setup Defaults
Pressing the <F9> key causes the following to display:
Load Optimized Defaults?
Yes No
If “Yes” is highlighted and <Enter> is pressed, all Setup fields are set to their
default values. If “No” is highlighted and <Enter> is pressed, or if the <Esc> key is
pressed, the user is returned to where they were before <F9> was pressed without
affecting any existing field values.
<F10>
Save and Exit
Pressing the <F10> key causes the following message to display:
Save configuration and reset?
Yes
No
If “Yes” is highlighted and <Enter> is pressed, all changes are saved and the
Setup is exited. If “No” is highlighted and <Enter> is pressed, or the <Esc> key is
pressed, the user is returned to where they were before <F10> was pressed
without affecting any existing values.
5.4.1.4
Setup Screen Menu Selection Bar
The Setup Screen Menu selection bar is located at the top of the BIOS Setup Utility screen. It
displays tabs showing the major screen selections available to the user. By using the left and
right arrow keys, the user can select the listed screens. Some screen selections are out of the
visible menu space, and become available by scrolling to the left or right of the current
selections displayed.
5.4.2
BIOS Setup Utility Screens
The following sections describe the screens available in the BIOS Setup utility for the
configuration of the server platform.
For each of these screens, there is an image of the screen with a list of Field Descriptions which
describe the contents of each item on the screen. Each item on the screen is hyperlinked to the
relevant Field Description. Each Field Description is hyperlinked back to the
screen image.
These lists follow the following guidelines:

66
The text heading for each Field Description is the actual text as displayed on the BIOS
Setup screen. This screen text is a hyperlink to its corresponding Field Description.
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface

The text shown in the Option Values and Help Text entries in each Field Description are
the actual text and values are displayed on the BIOS Setup screens.

In the Option Values entries, the text for default values is shown with an underline.
These values do not appear underline on the BIOS Setup screen. The underlined text in
this document is to serve as a reference to which value is the default value.

The Help Text entry is the actual text which appears on the screen to accompany the
item when the item is the one in focus (active on the screen).

The Comments entry provides additional information where it may be helpful. This
information does not appear on the BIOS Setup screens.

Information enclosed in angular brackets (< >) in the screen shots identifies text that can
vary, depending on the option(s) installed. For example, <Amount of memory installed>
is replaced by the actual value for “Total Memory”.

Information enclosed in square brackets ([ ]) in the tables identifies areas where the user
must type in text instead of selecting from a provided option.

Whenever information is changed (except Date and Time), the systems requires a save
and reboot to take place in order for the changes to take effect. Alternatively, pressing
<ESC> discards the changes and resumes POST to continue to boot the system
according to the boot order set from the last boot.
5.4.2.1
Map of Screens and Functionality
There are a number of screens in the entire Setup collection. They are organized into major
categories. Each category has a hierarchy beginning with a top-level screen from which lowerlevel screens may be selected. Each top-level screen appears as a tab, arranged across the top
of the Setup screen image of all top-level screens.
There are more categories than will fit across the top of the screen, so at any given time there
will be some categories which will not appear until the user has scrolled across the tabs which
are present.
Revision 1.4
67
BIOS Setup Interface
Intel® Server Board S1600JP TPS
The categories and the screens included in each category are listed as follows, with links to
each of the screens named:
Table 27. Screen Map
Categories (Top Tabs)
2nd Level Screens
3rd Level Screens
Main Screen (Tab)
Advanced Screen (Tab)

Processor Configuration

Power & Performance

Memory Configuration
Memory RAS and Performance
Configuration


Mass Storage Controller
Configuration

PCI Configuration

68
NIC Configuration

PCIe Port Oprom

USB Configuration

System Acoustic and
Performance Configuration
Control
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Categories (Top Tabs)
2nd Level Screens
3rd Level Screens
Security Screen (Tab)
Server Management Screen
(Tab)

Console Redirection

System Information

BMC LAN Configuration
Boot Options Screen (Tab)

CDROM Order

Hard Disk Order

Floppy Order

Network Device Order

BEV Device Order

Add EFI Boot Option

Delete EFI Boot Option
Boot Manager Screen (Tab)
Error Manager Screen (Tab)
Save and Exit Screen (Tab)
Revision 1.4
69
BIOS Setup Interface
5.4.2.2
Intel® Server Board S1600JP TPS
Main Screen (Tab)
The Main Screen is the first screen that appears when the BIOS Setup configuration utility is
entered, unless an error has occurred. If an error has occurred, the Error Manager Screen
appears instead.
Main
Advanced
Security
Server Management
Boot Options
Logged in as:
Administrator/User
Platform ID
<Platform Identification String>
Boot Manager
System BIOS
BIOS Version
<Platform.86B.xx.yy.zzzz>
Build Date
<MM/DD/YYYY>
Memory
Total Memory
<Amount of memory installed>
Quiet Boot
Enabled/Disabled
POST Error Pause
Enabled/Disabled
System Date
[Day MM/DD/YYYY]
System Time
[HH:MM:SS]
Figure 19. Main Screen
70
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 28. Setup Utility – Main Screen Fields
Setup
Item
Options
Help Text
Comments
Logged
in as
Administrator / User
None
Information only. Displays password level that setup is
running in: Administrator or User. With no passwords
set, Administrator is the default mode.
Platform
ID
Platform ID
None
Information only. Displays the Platform ID: S1600JP.
None
Information only. The BIOS version displayed uniquely
identifies the BIOS that is currently installed and
operational on the board. The version information
displayed is taken from the BIOS ID String, with the
timestamp segment dropped off. The segments
displayed are:
System BIOS
BIOS
Version
BIOS version ID
Platform: Identifies that this is the correct platform
BIOS.
86B: Identifies this BIOS as being an EPSD Server
BIOS.
xx: Major Revision level of the BIOS.
yy: Minor Revision level for this BIOS.
zzzz: Release Number for this BIOS.
Build
Date
Date and time when the
currently installed BIOS
was built
None
Information only. The time and date displayed are
taken from the timestamp segment of the BIOS ID
String.
Total
Memory
Amount of memory
installed in the system
None
Information only. Displays the total physical memory
installed in the system, in MB or GB. The term
physical memory indicates the total memory
discovered in the form of installed DDRIII DIMMs.
Quiet
Boot
Enabled
Disabled
[Enabled] – Display
the logo screen during
POST.
This field controls whether the full diagnostic
information is displayed on the screen during POST.
Memory
[Disabled] – Display
the diagnostic screen
during POST.
Revision 1.4
When Console Redirection is enabled, the Quiet Boot
setting is disregarded and the text mode Diagnostic
Screen is displayed unconditionally.
71
BIOS Setup Interface
Setup
Item
POST
Error
Pause
Options
Enabled
Disabled
Intel® Server Board S1600JP TPS
Help Text
[Enabled] – Go to the
Error Manager for
critical POST errors.
Comments
If enabled, the POST Error Pause option takes the
system to the error manager to review the errors when
major errors occur. Minor and fatal error displays are
not affected by this setting.
[Disabled] – Attempt
to boot and do not go
to the Error Manager
for critical POST
errors.
System
Date
System Date initially
displays the current
system calendar date,
including the day of the
week
System Date has
configurable fields for
Month, Day, and
Year.
The year must
bebetween 2005 and
2099.
This field will initially display the current system day of
week and date. It may be edited to change the system
date. When the System Date is reset by the “BIOS
Defaults” jumper, BIOS Recovery Flash Update, or
other method, the date will be the earliest date in the
allowed range – Saturday 01/01/2005.
Use [Enter] or [Tab]
key to select the next
field.
Use [+] or [-] key to
modify the selected
field.
System
Time
System Time initially
displays the current
system time of day, in
24-hour format
System Time has
configurable fields for
Hours, Minutes, and
Seconds.
Hours are in 24-hour
format.
This field will initially display the current system time
(24 hour time). It may be edited to change the system
time. When the System Time is reset by the “BIOS
Defaults” jumper, BIOS Recovery Flash Update, or
other method, the time will be the earliest time of day
in the allowed range – 00:00:00.
Use [Enter] or [Tab]
key to select the next
field.
Use [+] or [-] key to
modify the selected
field.
5.4.2.3
Advanced Screen (Tab)
The Advanced screen provides an access point to configure several groups of options. On this
screen, the user can select the option group to be configured. Configuration actions are
performed on the selected screen, and not directly on the Advanced screen.
To access this screen from the Main screen or other top-level “Tab” screen, press the right or
left arrow keys to traverse the tabs at the top of the Setup screen until the Advanced screen
is selected.
72
Revision 1.4
Intel® Server Board S1600JP TPS
Main
Advanced
BIOS Setup Interface
Security
Server Management
Boot Options
Boot Manager
► Processor Configuration
► Power & Performance
► Memory Configuration
► Mass Storage Controller Configuration
► PCI Configuration ► Serial Port Configuration
► USB Configuration
► System Acoustic and Performance Configuration
Figure 20. Advanced Screen
Table 29. Setup Utility – Advanced Screen Display Fields
Setup Item
Options
Help Text
Comments
Processor
Configuration
None
View/Configure processor
information and settings.
Selection only. Select this line and press
the <Enter> key to go to the Processor
Configuration group of configuration
settings.
Power &
Performance
None
View/Configure power and
performance policy.
Selection only. Select this line and press
the <Enter> key to go to the Power and
Performance group of configuration
settings.
Memory
Configuration
None
View/Configure memory
information and settings.
Selection only. Select this line and press
the <Enter> key to go to the Memory
Configuration group of configuration
settings.
Mass Storage
Controller
Configuration
None
View/Configure mass
storage controller
information and settings.
Selection only. Select this line and press
the <Enter> key to go to the Mass Storage
Controller Configuration group of
configuration settings.
Revision 1.4
73
BIOS Setup Interface
Setup Item
Intel® Server Board S1600JP TPS
Options
View/Configure PCI
information and settings.
Selection only. Select this line and press
the <Enter> key to go to the PCI
Configuration group of configuration
settings.
None
View/Configure serial port
information and settings.
Selection only. Select this line and press
the <Enter> key to go to the Serial Port
Configuration group of configuration
settings.
None
View/Configure USB
information and settings.
Selection only. Select this line and press
the <Enter> key to go to the USB
Configuration group of configuration
settings.
View/Configure system
acoustic and performance
information and settings.
Selection only. Select this line and press
the <Enter> key to go to the System
Acoustic and Performance Configuration
group of configuration settings.
USB Configuration
System Acoustic and None
Performance
Configuration
74
Comments
None
PCI Configuration
Serial Port
Configuration
Help Text
Revision 1.4
Intel® Server Board S1600JP TPS
5.4.2.4
BIOS Setup Interface
Processor Configuration
The Processor Configuration screen displays the processor identification and microcode level,
core frequency, cache sizes for all processors currently installed. It also allows the user to
enable or disable a number of processor options.
To access this screen from the Main screen, select Advanced > Processor Configuration. To
move to another screen, press the <Esc> key to return to the Advanced screen, then select the
desired screen.
Advanced
Processor Configuration
Processor Socket
CPU 1
Processor ID
<CPUID>*
Processor Frequency
<Proc Freq>
Microcode Revision
<Rev data>
L1 Cache RAM
<L1 Cache Size>
L2 Cache RAM
<L2 Cache Size>
L3 Cache RAM
<L3 Cache Size>
Processor 1 Version
<ID string from Processor 1>
Intel(R) Turbo Boost Technology
Enabled/Disabled
Enhanced Intel SpeedStep(R) Tech
Enabled/Disabled
Processor C3
Enabled/Disabled
Processor C6
Enabled/Disabled
Intel(R) Hyper-Threading Tech
Enabled/Disabled
Active Processor Cores
All/1/2/3/4/5/6/7
Execute Disable Bit
Enabled/Disabled
Intel (R) Virtualization Technology
Enabled/Disabled
Revision 1.4
75
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Intel(R) VT for Directed I/O
Enabled/Disabled
Interrupt Remapping
Enabled/Disabled
Coherency Support
Enabled/Disabled
ATS Support
Enabled/Disabled
Pass-through DMA Support
Enabled/Disabled
Intel(R) TXT
Enabled/Disabled
Enhanced Error Containment Mode
Enabled/Disabled
MLC Streamer
Enabled/Disabled
MLC Spatial Prefetcher
Enabled/Disabled
DCU Data Prefetcher
Enabled/Disabled
DCU Instruction Prefetcher
Enabled/Disabled
Direct Cache Access (DCA)
Enabled/Disabled
Extended ATR
0x03/0x01
PFloor tuning [Maximum Non-Turbo Frequency minus 3 – 12,12 is default]
SMM Wait Timeout
[20 – 3000ms, 20 is default]
Figure 21. Processor Configuration Screen
Table 30. Setup Utility – Processor Configuration Screen Fields
Setup Item
76
Options
Help Text
Comments
Processor ID
CPUID
None
Information only. Processor
CPUID.
Processor
Frequency
Current Processor
Operating Frequency
None
Information only. Current
frequency of the processor.
Microcode
Revision
Microcode Revision
Number
None
Information only. Revision of the
loaded microcode.
Revision 1.4
Intel® Server Board S1600JP TPS
Setup Item
BIOS Setup Interface
Options
Help Text
Comments
L1 Cache RAM
L1 cache size
None
Information only. Displays size in
KB of the processor L1 Cache.
Since L1 cache is not shared
between cores, this is shown as
the amount of L1 cache per core.
There are two types of L1 cache,
so this amount is the total of L1
Instruction Cache plus L1 Data
Cache for each core.
L2 Cache RAM
L2 cache size
None
Information only. Displays size in
KB of the processor L2 Cache.
Since L2 cache is not shared
between cores, this is shown as
the amount of L2 cache per core.
L3 Cache RAM
L3 cache size
None
Information only. Displays size in
MB of the processor L3 Cache.
Since L3 cache is shared
between all cores in a processor
package, this is shown as the
total amount of L3 cache per
processor package.
Processor 1
Version
ID string from
processor
None
Information only. Displays Brand
ID string of processor with CPUID
instruction.
Enabled
Disabled
Intel Turbo Boost
Technology allows the
processor to automatically
increase its frequency if it is
running below power,
temperature, and current
specifications.
®
This option is only visible if the
processor in the system support
®
Intel Turbo Boost Technology. In
order for this option to be
®
available, Enhanced Intel
®
SpeedStep Technology must be
Enabled.
Enabled
Disabled
Enhanced Intel SpeedStep
Technology allows the system
to dynamically adjust
processor voltage and core
frequency, which can result in
decreased average power
consumption and decreased
average heat production.
®
Intel Turbo
Boost
Technology
Enhanced Intel
®
SpeedStep
Technology
®
®
®
Contact your OS vendor
regarding OS support of this
feature.
Revision 1.4
When Disabled, the processor
setting reverts to running at Max
TDP Core Frequency (rated
frequency).
This option is only visible if all
processors installed in the
®
system support Enhanced Intel
®
SpeedStep Technology. In order
for the Intel® Turbo Boost option
®
to be available, Enhanced Intel
®
SpeedStep Technology must be
Enabled.
77
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Setup Item
Processor C3
Options
®
Intel HyperThreading
Technology
Comments
Enable/Disable Processor C3
(ACPI C2/C3) report to OS
This is normally Disabled, but
can be Enabled for improved
performance on certain
benchmarks and in certain
situations.
Enabled
Disabled
Enable/Disable Processor C6
(ACPI C3) report to OS
This is normally Enabled but can
be Disabled for improved
performance on certain
benchmarks and in certain
situations.
Enabled
Disabled
Intel Hyper-Threading
Technology allows
multithreaded software
applications to execute
threads in parallel within each
processor.
Enabled
Disabled
Processor C6
Help Text
®
This option is only visible if all
processors installed in the system
®
support Intel Hyper-Threading
Technology.
Contact your OS vendor
regarding OS support of this
feature.
Active
Processor
Cores
All
1
2
3
4
5
6
7
Number of cores to enable in
each processor package.
The numbers of cores that appear
as selections depends on the
number of cores available in the
processors installed. Boards may
have as many as eight cores in
each of 1, 2, or 4 processors. The
same number of cores must be
active in each processor package.
This Setup screen should begin
with the number of currentlyactive cores as the number
displayed. See note below – this
may be different from the number
previously set by the user.
Note: The ME can control the
number of active cores
independently of the BIOS Setup
setting. If the ME disables or
enables processor cores, that will
override the BIOS setting, and
the number selected by BIOS will
be disregarded.
78
Revision 1.4
Intel® Server Board S1600JP TPS
Setup Item
Execute Disable
Bit
BIOS Setup Interface
Options
Enabled
Disabled
Help Text
Execute Disable Bit can help
prevent certain classes of
malicious buffer overflow
attacks.
Contact your OS vendor
regarding OS support of this
feature.
®
Intel
Virtualization
Technology
Enabled
Disabled
®
Intel Virtualization
Technology allows a platform
to run multiple operating
systems and applications in
independent partitions.
Note: A change to this option
requires the system to be
powered off and then back on
before the setting takes effect.
Enabled
®
Intel VT for
Directed I/O
Disabled
®
Enable/Disable Intel
Virtualization Technology for
®
Directed I/O. (Intel VT-d)
Report the I/O device
assignment to VMM through
DMAR ACPI Tables
Enabled
This option is only visible if all
processors installed in the
®
system support Intel VT-d. The
software configuration installed
on the system must support this
feature in order for it to be
enabled.
®
This option only appears when
®
Intel Virtualization Technology
for Directed I/O is Enabled.
®
This option only appears when
®
Intel Virtualization Technology
for Directed I/O is Enabled.
®
This option only appears when
®
Intel Virtualization Technology
for Directed I/O is Enabled. For
some processors this will be
enabled unconditionally
®
whenever Intel VT-d is enabled.
In that case, this option will be
shown as "Enabled", and grayed
out and not changeable.
Coherency
Support
Enabled
Disabled
Enable/Disable Intel VT-d
Coherency support.
ATS Support
Enabled
Disabled
Enable/Disable Intel VT-d
Address Translation Services
(ATS) support.
Pass-through
DMA Support
Enabled
Enable/Disable Intel VT-d
Pass-through DMA support.
For some processors, this
option may be "always
enabled".
Revision 1.4
This option is only visible if all
processors installed in the system
®
support Intel VT. The software
configuration installed on the
system must support this feature
in order for it to be enabled.
This option only appears when
®
Intel Virtualization Technology
for Directed I/O is Enabled. For
some processors this will be
enabled unconditionally
whenever Intel® VT-d is enabled.
In that case, this option will be
shown as "Enabled", and grayed
out and not changeable.
Disabled
Disabled
This option is only visible if all
processors installed in the system
support the Execute Disable Bit.
The OS and applications installed
must support this feature in order
for it to be enabled.
®
Enable/Disable Intel VT-d
Interrupt Remapping support.
For some processors, this
option may be "always
enabled".
Interrupt
Remapping
Comments
79
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Setup Item
®
Intel TXT
Options
Enabled
Disabled
Enhanced Error
Containment
Mode
Enabled
MLC Streamer
Enabled
Disabled
Disabled
Help Text
®
Enable/Disable Intel Trusted
Execution Technology. Takes
effect after reboot.
Intel TXT only appears with
products and processors which
has TXT support capability. This
option is only available when both
®
Intel Virtualization Technology
®
and Intel VT for Directed IO are
enabled and on models equipped
with a TPM. The TPM must be
®
active in order to support Intel
TXT. Changing the setting for
®
Intel TXT will require the system
to perform a Hard Reset in order
for the new setting to become
effective.
Enable Enhanced Error
Containment Mode (Data
Poisoning) - Erroneous data
coming from memory will be
poisoned. If disabled (default),
will be in Legacy Mode - No
data poisoning support
available.
Enhanced Error Containment
(Data Poisoning) is not supported
by all models of processors, and
this option will not appear unless
all installed processors support
Enhanced Error Containment.
This option globally enables or
disables both Core and Uncore
Data Poisoning, for processors
which support them.
MLC Streamer is a
speculative prefetch unit
within the processor(s)
MLC Streamer is normally
Enabled, for best efficiency in L2
Cache and Memory Channel use,
but disabling it may improve
performance for some processing
loads and on certain benchmarks.
Note: Modifying this setting
may affect performance.
MLC Spatial
Prefetcher
Enabled
Disabled
[Enabled] – Fetches adjacent
cache line (128 bytes) when
required data is not currently
in cache.
[Disabled] – Only fetches
cache line with data required
by the processor (64 bytes).
DCU Data
Prefetcher
Enabled
Disabled
Comments
®
[Enabled] The next cache line
will be prefetched into L1 data
cache from L2 or system
memory during unused cycles
if it sees that the processor
core has accessed several
bytes sequentially in a cache
line as data.
MLC Spatial Prefetcher is
normally Enabled, for best
efficiency in L2 Cache and
Memory Channel use, but
disabling it may improve
performance for some processing
loads and on certain benchmarks.
DCU Data Prefetcher is normally
Enabled, for best efficiency in L1
Data Cache and Memory Channel
use, but disabling it may improve
performance for some processing
loads and on certain benchmarks.
[Disabled] – Only fetches
cache line with data required
by the processor (64 bytes).
80
Revision 1.4
Intel® Server Board S1600JP TPS
Setup Item
BIOS Setup Interface
Options
Help Text
Comments
DCU Instruction
Prefetcher
Enabled
Disabled
The next cache line will be
prefetched into L1 instruction
cache from L2 or system
memory during unused cycles
if it sees that the processor
core has accessed several
bytes sequentially in a cache
line as data.
DCU Instruction Prefetcher is
normally Enabled, for best
efficiency in L1 I Cache and
Memory Channel use, but
disabling it may improve
performance for some processing
loads and on certain benchmarks.
Direct Cache
Access (DCA)
Enabled
Disabled
Allows processors to increase
the I/O performance by
placing data from I/O devices
directly into the processor
cache.
System performance is usually
best with Direct Cache Access
Enabled. In certain unusual
cases, disabling this may give
improved results.
Extended ATR
0x03
Extended Timeout value for
PCIe tuning. 0x03 = default
timeout. 0x01 = extended
timeout.
Adjust ATR value to PCIe
performance improvement.
Adjustment of CPU idle
frequency for PCIe Bus tuning
between 12 and 3 less than
CPU rated frequency.
Adjustment of CPU idle frequency
for PCIe performance tuning.
Millisecond timeout waiting for
BSP and APs to enter SMM.
Range is 20ms to 3000ms
Amount of time to allow for the
SMI Handler to respond to an
SMI. If exceeded, BMC generates
an SMI Timeout and resets the
system.
0x01
PFloor tuning
SMM Wait
Timeout
Entry Field maximum
Non-Turbo
Frequency -3 of
installed
Processors –
12, 12 is default
Entry Field 20 –
3000ms, 20 is
default
Note: This field is temporary, and
will be removed when no longer
required.
5.4.2.5
Power and Performance policy
The Power and Performance screen allows the user to specify a profile which is optimized in the
direction of either reduced power consumption or increased performance.
To access this screen from the Main screen, select Advanced > Power and Performance. To
move to another screen, press the <Esc> key to return to the Advanced screen, then select the
desired screen.
Revision 1.4
81
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Advanced
Power & Performance
CPU Power and Performance Policy
Performance / Balanced Performance /
Balanced Power / Power
[Performance] Optimization is strongly toward performance, even at the expense of energy efficiency.
[Balanced Performance] Weights optimization toward performance, while conserving energy.
[Balanced Power] Weights optimization toward energy conservation, with good performance.
[Power] Optimization is strongly toward energy efficiency, even at the expense of performance.
Figure 22. Power and Performance Configuration Screen
Table 31. Setup Utility – Power and Performance Configuration Screen Fields
Setup Item
Options
CPU Power and Performance
Performance
Balanced
Policy
Performance
Balanced Power
Power
Help Text
Allows the user to set an overall
power and performance policy for
the system, and when changed
will modify a selected list of
options to achieve the policy.
These options are still
changeable outside of the policy
but do reflect the changes that
the policy makes when a new
policy is selected.
Comments
Choosing one of these four Power and
Performance Profiles implements a
number of changes in BIOS settings,
both visible settings in the Setup screens
and non-visible internal settings. For
detailed lists of settings affected by each
profile, see Table 32.
When the user selects a Power and Performance Policy in Setup, there is a list of
complementary settings which are made. These can be individually overridden after the policy
setting has been selected and the profile settings performed. The profile settings are listed in
the following table.
82
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 32. Power/Performance Profiles
BIOS Features
Available Settings
Performance
Balanced
Performance
Balanced
Power
Power
Setup: Advanced > Power and Performance
CPU Power and
Performance Policy
Performance
/Balanced
Performance
/Balanced Power
/Power
Performance
(Balanced
Performance)
Balanced
Power
Power
Setup: Advanced > Processor Configuration
®
Auto Max
/6.4 GT/s
/7.2 GT/s
/8.0 GT/s
(Auto Max)
(Auto Max)
(Auto Max)
6.4 GT/s
®
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Processor C3
Enabled/Disabled
(Disabled)
(Disabled)
(Disabled)
(Disabled)
Processor C6
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Intel Hyper
Threading
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Active Processor
Cores
All/1/2/3/4/5/6/7
(All)
(All)
(All)
(All)
MLC Streamer
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
MLC Spatial
Prefetcher
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
DCU Data
Prefetcher
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
DCU Instruction
Prefetcher
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Direct Cache
Access (DCA)
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Memory Operating
Speed Selection
Auto/800/1067
/1333/1600
(Auto)
(Auto)
(Auto)
(Auto)
Patrol Scrub
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Intel QPI
Frequency Select
Intel Turbo Boost
Technology
Enhanced Intel
®
SpeedStep
Technology
®
®
Setup: Advanced > Memory Configuration
Revision 1.4
83
BIOS Setup Interface
Intel® Server Board S1600JP TPS
BIOS Features
Available Settings
Performance
Demand Scrub
Enabled/Disabled
Set Throttling Mode
Auto/DCLTT
/SCLTT/SOLTT
(Auto)
(Auto)
(Auto)
(Auto)
Set Fan Profile
Performance
/Acoustic
(Performance)
(Performance)
(Performance)
(Performan
ce)
Quiet Fan Idle
Mode
Enabled/Disabled
(Disabled)
(Disabled)
(Disabled)
(Disabled)
EuP LOT6 OFFMode
Enabled/Disabled
(Disabled)
(Disabled)
QPI Link L0S
enable
Auto/Enabled
/Disabled
Disabled
(Auto)
(Auto)
(Auto)
CKE Throttling
Auto/Enabled
/Disabled
Disabled
(Auto)
(Auto)
Enabled
Memory Voltage
Auto/1.5V/1.35V
1.5v
(Auto)
(Auto)
(Auto)
CPU PkgC State
Limit
Disabled/C6 with
no retention/C6
with retention
Disabled
(C6 with
retention)
(C6 with
retention)
(C6 with
retenti
on)
Processor C1
mapped to ACPI
C1
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Processor C6 with
retention mapped
to ACPI C2
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
ACPI C3
Enabled/Disabled
(Disabled)
(Disabled)
(Disabled)
(Disabled)
Processor C1/C3
Auto Demotion
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
Processor C1/C3
UnDemotion
Enabled/Disabled
(Enabled)
(Enabled)
(Enabled)
(Enabled)
ENERGY_PERF
_BIAS mode
Performance/Bala
nced
Performance/Bala
nced Power/Power
Performance
(Balanced
Performance)
Balanced
Power
Power
(Enabled)
Balanced
Performance
(Enabled)
Balanced
Power
(Enabled)
Power
(Enabled)
Setup: Advanced > System Acoustic and Performance Configuration
Setup: Server Management
(Disabled)
(Disabled)
Internal BIOS Settings not displayed in BIOS Setup
84
Revision 1.4
Intel® Server Board S1600JP TPS
5.4.2.6
BIOS Setup Interface
Memory Configuration
The Memory Configuration screen allows the user to view details about the DDRIII DIMMs that
are installed as system memory, and alter BIOS Memory Configuration settings where
appropriate.
To access this screen from the Main screen, select Advanced > Memory Configuration. To
move to another screen, press the <Esc> key to return to the Advanced screen, then select the
desired screen.
Advanced
Memory Configuration
Total Memory
<Total Physical Memory Installed in System>
Effective Memory
<Total Effective Memory>
Current Configuration
<Independent/Mirror/Rank Sparing/Lockstep>
Current Memory Speed
<Operational Memory Speed in MT/s>
Memory Operating Speed Selection
Auto/800/1066/1333/1600
Memory SPD Override
Enabled/Disabled
Patrol Scrub
Enabled/Disabled
Demand Scrub
Enabled/Disabled
Correctable Error Threshold
None/ALL/5/10/20
► Memory RAS and Performance Configuration
DIMM Information
DIMM_A1
<DIMM Size> <DIMM Status>
DIMM_A2
<DIMM Size> <DIMM Status>
Revision 1.4
85
BIOS Setup Interface
Intel® Server Board S1600JP TPS
DIMM_B1
<DIMM Size> <DIMM Status>
DIMM_B2
<DIMM Size> <DIMM Status>
DIMM_C1
<DIMM Size> <DIMM Status>
DIMM_C2
<DIMM Size> <DIMM Status>
DIMM_D1
<DIMM Size> <DIMM Status>
DIMM_D2
<DIMM Size> <DIMM Status>
Figure 23. Memory Configuration Screen
Table 33. Setup Utility – Memory Configuration Screen Fields
Setup Item
Options
Help Text
Comments
Total Memory
Total Physical
Memory installed
in System
None
Information only. The amount of memory
available in the system in the form of installed
DDRIII DIMMs in units of GB.
Effective
Memory
Total Effective
Memory
None
Information only. Displays the amount of
memory available to the OS in MB or GB.
The Effective Memory is the Total Physical
Memory minus the sum of all memory
reserved for internal usage, RAS redundancy
and SMRAM.
Note: Some server operating systems do not
display the total physical memory installed.
Current
Configuration
Independent
Channel
Mirror
Rank Sparing
Lockstep
None
Information only: Displays one of the
following:
Independent Channel – DIMMs are operating
in Independent Channel Mode, the default
configuration when there is no RAS Mode
configured.
Mirror – Mirroring RAS Mode has been
configured and is operational.
Rank Sparing – Rank Sparing RAS Mode has
been configured and is operational.
Lockstep – Lockstep RAS Mode has been
configured and is operational.
86
Revision 1.4
Intel® Server Board S1600JP TPS
Setup Item
Current
Memory Speed
Options
Operational
Memory Speed in
MT/s
BIOS Setup Interface
Help Text
None
Comments
Information only. Displays the speed in MT/s
at which the memory is currently running.
The supported memory speeds are 800 MT/s,
1066 MT/s, 1333 MT/s, and 1600 MT/s. The
actual memory speed capability depends on
the memory configuration.
Memory
Operating
Speed
Selection
Auto
800
Force specific Memory
Operating Speed or use Auto
setting.
Allows the user to select a specific speed at
which memory will operate. Only speeds that
are legitimate are available, that is, the user
can only specify speeds less than or equal to
the auto-selected Memory Operating Speed.
The default Auto setting will select the highest
achievable Memory Operating Speed
consistent with the DIMMs and processors
installed.
When enabled, it extends the
platform’s capability to
support higher Memory
Frequency than the POR
Settings; Disabling it keeps
the POR settings.
None
1066
1333
1600
Memory SPD
Override
Enabled
Patrol Scrub
Enabled
Disabled
When enabled, performs
periodic checks on memory
cells and proactively walks
through populated memory
space, to seek and correct
soft ECC errors.
When enabled, Patrol Scrub is initialized to
read through all of memory in a 24-hour
period, correcting any Correctable ECC Errors
it encounters by writing back the corrected
data to memory.
Demand Scrub
Enabled
Disabled
When enabled, executes
when an ECC error is
encountered during a normal
read/write of data and
corrects that data.
When enabled, Demand Scrub automatically
corrects a Correctable ECC Error encountered
during a fetch from memory by writing back
the corrected data to memory.
Revision 1.4
Disabled
87
BIOS Setup Interface
Setup Item
Correctable
Error Threshold
Intel® Server Board S1600JP TPS
Options
None
All
5
10
20
Help Text
Threshold value for logging
Correctable Errors (CE) –
Threshold of 10 (default) logs
10th CE, "All" logs every CE
and “None”’ means no CE
logging. All and None are not
valid with Rank Sparing.
Comments
Specifies how many Correctable Errors must
occur before triggering the logging of a SEL
Correctable Error Event. Only the first
threshold crossing is logged, unless “All” is
selected. “All” causes every CE that occurs to
be logged. “None” suppresses CE logging
completely.
When Rank Sparing RAS Mode is configured,
“All” and “None” are not valid, so they will not
be presented as choices.
This threshold is applied on a per-rank basis.
The Correctable Error occurrences are
counted for each memory rank. When any one
rank accumulates a CE count equal to the CE
Threshold, then a single CE SEL Event is
logged, and all further CE logging is
suppressed.
Note that the CE counts are subject to a
“leaky bucket” mechanism that reduces the
count as a function of time, to keep from
accumulating counts unnecessarily over the
term of a long operational run.
This is also the Correctable Error threshold
used when Rank Sparing RAS Mode is
configured. When a CE threshold crossing
occurs in Rank Sparing Mode on a channel
which is in Redundant state, it causes a
Sparing Fail Over (SFO) event to occur. That
threshold crossing will also be logged as a
Correctable Error event if it is the first to occur
on the system.
An SFO event causes the rank with the error
to be replaced by the spare rank for that
channel and the channel goes to a nonredundant state (with a “Redundancy
Degraded” SEL Event logged). There may be
an SFO for each channel in the system,
although only the first one can be logged as a
CE event.
Memory RAS
and
Performance
Configuration
88
None
Configure memory RAS
(Reliability, Availability, and
Serviceability) and view
current memory performance
information and settings.
Selection only. Select this line and press the
<Enter> key to go to the Memory RAS and
Performance Configuration group of
configuration settings.
Revision 1.4
Intel® Server Board S1600JP TPS
Setup Item
DIMM_ XY
Options
<DIMM Size>
<DIMM Status>
BIOS Setup Interface
Help Text
Comments
None
Information only: Displays the status of each
DIMM socket present on the board. There is
one line for each DIMM socket present on the
board.
Where DIMM
Size is: Size of
DIMM in GB
For each DIMM socket, the DIMM Status
reflects one of the following three possible
states:
Where DIMM
Status is:
Installed and Operational – There is a DDRIII
DIMM installed and operational in this slot.
Installed and
Operational
Not Installed – There is no DDRIII DIMM
installed in this slot.
Not Installed
Failed/Disabled
Failed/Disabled – The DIMM installed in this
slot has failed during initialization and/or was
disabled during initialization.
For each DIMM that is in the Installed &
Operational state, the DIMM Size in GB of that
DIMM is displayed. This is the physical size of
the DIMM, regardless of how it is counted in
the Effective Memory size.
5.4.2.7
Memory RAS and Performance Configuration
The Memory RAS and Performance Configuration screen allows the user to customize several
memory configuration options, such as whether to use Memory Mirroring or Memory Sparing.
To access this screen from the Main screen, select Advanced > Memory Configuration >
Memory RAS and Performance Configuration. To move to another screen, press the <Esc>
key to return to the Memory Configuration screen, if necessary press the <Esc> key again to
return to the Advanced screen, then select the desired screen.
Revision 1.4
89
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Advanced
Memory RAS and Performance Configuration
Capabilities
Memory Mirroring Possible
Yes/No
Memory Rank Sparing Possible
Yes/No
Memory Lockstep Possible
Yes/No
Select Memory RAS Configuration
Maximum Performance/Mirroring/Lockstep
Figure 24. Memory RAS and Performance Configuration Screen
Table 34. Setup Utility – Memory RAS and Performance Configuration Fields
Setup Item
Options
Memory
Mirroring
Possible
Yes
Memory Rank
Sparing
Possible
Yes
Help Text
Information only. Displays whether the current
DIMM configuration is capable of Memory
Mirroring. For Memory Mirroring to be possible,
DIMM configurations on all paired channels must
be identical between the channel pair (Mirroring
Domain).
None
Information only. Displays whether the current
DIMM configuration is capable of Rank Sparing.
For Rank Sparing to be possible, DIMM
configurations on all channels must be capable of
supporting Rank Sparing.
No
No
Comments
None
Note: The Correctable Error Threshold value is
also the Sparing Fail Over threshold value.
Threshold values of “All” or “None” are not valid
for Rank Sparing. If the Correctable Error
Threshold is set to either of those values, Rank
Spring will not be possible.
90
Revision 1.4
Intel® Server Board S1600JP TPS
Setup Item
Options
Memory
Lockstep
Possible
Yes
Select Memory
RAS
Configuration
Maximum
Performance
BIOS Setup Interface
Help Text
None
Information only. Displays whether the current
DIMM configuration is capable of Memory
Lockstep. For Memory Lockstep to be possible,
DIMM configurations on all paired channels must
be identical between the channel pair.
Allows the user to
select the memory RAS
Configuration to be
applied for the next
boot.
Available modes depend on the current memory
population. Modes which are not listed as
“possible” should not be available as choices. If
the only valid choice is “Maximum Performance”,
then this option should be grayed out and
unavailable.
No
Mirroring
Rank Sparing
Comments
Lockstep
Maximum Performance – (default) no RAS but
best memory utilization since full amount of
memory is available; operating in Independent
Channel Mode.
Mirroring - most reliability by using half of
memory as a mirror image; can survive an
Uncorrectable ECC Error.
Rank Sparing – offers reliability by reserving
spare ranks to replace failing ranks which are
generating excessive Correctable ECC Errors.
Lockstep – allows SDDC capability with x8
DIMMs installed. No memory size impact but
does have a performance and power penalty.
Note: Since only RAS Modes which are listed as
“possible” are available for selection, it is not
possible to select a RAS Mode without first
installing an appropriate DIMM configuration.
5.4.2.8
Mass Storage Controller Configuration
The Mass Storage Configuration screen allows the user to configure the Mass Storage
controllers that are integrated into the server board on which the BIOS is executing.
Revision 1.4
91
BIOS Setup Interface
Intel® Server Board S1600JP TPS
To access this screen from the Main screen, select Advanced > Mass Storage Controller
Configuration. To move to another screen, press the <Esc> key to return to the Advanced
screen, then select the desired screen.
Advanced
Mass Storage Controller Configuration
AHCI Controller Configuration
<AHCI Port Configuration>
SATA/SAS Controller Configuration
<SCU SAS/SATA Port Configuration>
AHCI Capable SATA Controller
Disabled/Compatibility/Enhanced/AHCI/RAID Mode
AHCI HDD Staggered Spin-Up
Enabled/Disabled
AHCI Capable RAID Options
INTEL(R) ESRT2 (LSI*) / INTEL(R) RSTe
SAS/SATA Capable Controller
Disabled / INTEL(R) ESRT2 (LSI*) / INTEL(R) RSTe
RSTe Boot Configuration
Neither / AHCI Capable Ctrlr / SAS/SATA Capable Ctrlr
Intel(R) Storage Module
- None / <Name of storage module detected >
SATA Port 0
Not Installed / <Drive Information>
SATA Port 1
Not Installed / <Drive Information>
SATA Port 2
Not Installed / <Drive Information>
SATA Port 3
Not Installed / <Drive Information>
SATA Port 4
Not Installed / <Drive Information>
SATA Port 5
Not Installed / <Drive Information>
Figure 25. Mass Storage Controller Configuration Screen
92
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 35. Mass Storage Controller Configuration Fields
Setup Item
Options
Help Text
Comments
AHCI
Controller
Configuration
AHCI Port
Configuration
None
Information only. This is a display showing
which ports are available through the
onboard AHCI capable SATA controller, if
the controller is enabled.
SATA/SAS
Controller
Configuration
SCU
SAS/SATA
Port
Configuration
None
Information only. This is a display showing
the number of ports which are available
through the SCU controller, and whether
they are configured for SATA or SAS.
AHCI Capable
SATA
Controller
Disabled
- Compatibility provides PATA
emulation on the SATA
device.
- Enhanced provides Native
SATA support.
- AHCI enables the Advanced
Host Controller Interface,
which provides Enhanced
SATA functionality.
- RAID Mode provides host
based RAID support on the
onboard SATA ports.
This option configures the onboard AHCIcapable SATA controller, which is distinct
from the SCU.
If enabled for the AHCI
Capable SATA controller,
Staggered Spin-Up will be
performed on drives attached
to it. Otherwise these drives
will all spin up at boot.
This option enables or disables Staggered
Spin-up only for disk drives attached to ports
on the AHCI Capable SATA Controller. Disk
drives attached to SATA/SAS ports on the
Storage Control Unit are controlled by a
different method for Staggered Spin-Up and
this option does not affect them.
Compatibility
Enhanced
AHCI
RAID Mode
AHCI HDD
Staggered
Spin-Up
Enabled
Disabled
If the SATA Controller is Disabled, the SATA
Ports will not operate, and any installed
SATA devices will be unavailable.
Compatibility provides PATA emulation on
the SATA device, allowing the use of legacy
IDE/PATA drivers. Enhanced provides
Native SATA support using native SATA
drivers included with the vast majority of
current OSes. AHCI enables the Advanced
Host Controller Interface, which provides
Enhanced SATA functionality plus possible
additional functionality (Native Command
Queuing, Hot Plug, Staggered Spin Up). It
uses AHCI drivers available for the majority
of current OSes. RAID Mode provides host
based RAID support on the onboard SATA
ports. RAID levels supported and required
drivers depend on the RAID stack selected.
This option is only visible when the SATA
Controller is enabled and AHCI or RAID has
been selected as the operational SATA
Mode.
Revision 1.4
93
BIOS Setup Interface
Setup Item
AHCI Capable
RAID Options
Intel® Server Board S1600JP TPS
Options
®
Intel ESRT2
(LSI*)
®
Intel RSTe
Help Text
This option only appears when the SATA
Controller is enabled, and RAID Mode has
been selected as the operational SATA
Mode. This setting selects the RAID stack to
be used for SATA RAID with the onboard
AHCI SATA controller.
®
If a RAID Volume has not previously been
created that is compatible with the RAID
stack selected, it will be necessary to Save
and Exit and reboot in order to create a
RAID Volume.
®
This option selects the RAID stack to be
used with the SCU. If Disabled is selected,
any drives connected to the SCU will not be
usable.
- Intel ESRT2 (Powered By
LSI*): Supports RAID 0/1/10
®
and optional RAID 5 with Intel
RAID C600 Upgrade Keys.
®
Uses Intel ESRT2 drivers
(based on LSI* MegaSR).
- Intel RSTe: Provides passthrough drive support. Also
provides host based RAID
®
0/1/10/5 support. Uses Intel
RSTe iaStor drivers.
SAS/SATA
Capable
Controller
Disabled
®
Intel ESRT2
(LSI*)
®
Intel RSTe
Comments
®
- Intel ESRT2: Provides host
based RAID 0/1/10 and
optional RAID 5. Uses
®
Intel ESRT2 drivers (based on
LSI* MegaSR).
®
- Intel RSTe: Provides passthrough drive support. Also
provides host based RAID
0/1/10 support, and RAID 5 (in
®
SATA mode only). Uses Intel
RSTe iaStor drivers.
Intel® ESRT2 provides host based RAID
0/1/10 and optional RAID 5. For a RAID 5
®
configuration, this requires one of the Intel
®
RAID C600 Upgrade Keys uses Intel
ESRT2 drivers (based on LSI* MegaSR),
and is also supported by Linux MDRAID.
®
Intel RSTe provides pass-through drive
support and provides host based RAID
0/1/10 support, and RAID 5 (in SATA mode
®
only). Uses Intel RSTe drivers in
Windows*, and MDRAID stack in Linux*.
®
The Intel RSTe RAID stack is required if it
is necessary to provide pass-through
support for non-RAID drives, or if support is
needed for more than eight drives.
94
Revision 1.4
Intel® Server Board S1600JP TPS
Setup Item
RSTe Boot
Configuration
BIOS Setup Interface
Options
Neither
AHCI Capable
Ctrlr
SAS/SATA
Capable Ctrlr
Help Text
This selects the device that
will support Bootable Drives,
whether they are in RAID
arrays or individual passthrough SAS/SATA drives.
Once selected and set up (if
necessary), individual
bootable devices will be listed
in the Bootable Devices menu
display.
Comments
®
This option appears only when Intel RSTe
has been selected as the operational mode
on both the AHCI and SCU controllers. In
that case there is a conflict and only one
controller can be selected as having
bootable drives attached.
Once selected and set up (if necessary),
individual bootable logical or physical drives
available on the selected controller will be
listed in the Bootable Devices menu display.
If only one device selects RSTe, it will be
available as a boot device along with any
other devices – this option is only necessary
to distinguish between which the RSTe
device runs the Option ROM instance.
BIOS is required to designate the OPROM
for the boot device selected here. Two
iterations of the OPROM cannot fully load
simultaneously, and the version fully loaded
will only show devices connected to the
given controller, so the OPROM load order
is based on BIOS selecting the correct
device.
Note: If RSTe is selected, then only one
CONTROLLER can be bootable, so there
will be situations where the boot drive *OR*
an optical device will be bootable but not
both.
®
®
Intel Storage
Module
Name of
Storage
Module
detected
None
Information Only. If no Intel Storage
Module is detected, then None is displayed.
This shows the customer the product name
of the module installed, which helps in
identifying drivers, support, documentation,
and so on.
SATA Port x
Not Installed
Drive
Information
None
Information only. The Drive Information,
when present, will typically consist of the
drive model identification and size for the
disk drive installed on a particular port.
5.4.2.9
PCI Configuration
The PCI Configuration screen allows the user to configure the PCI memory space used for
onboard and add-in adapters, configure video options, and configure onboard adapter options. It
also displays the NIC MAC Addresses currently in use.
To access this screen from the Main screen, select Advanced > PCI Configuration. To move
to another screen, press the <Esc> key to return to the Advanced screen, then select the
desired screen.
Revision 1.4
95
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Advanced
PCI Configuration
Maximize Memory below 4GB
Enabled / Disabled
Memory Mapped I/O above 4 GB
Enabled / Disabled
Memory Mapped I/O Size
Auto/1G/2G/4G/8G/16G/32G/64G/128G/256G/512G/
1024G
Onboard Video
Enabled / Disabled
Dual Monitor Video
Enabled / Disabled
NTB PCIe Port on CPU socket 1
Transparent Bridge/NTB to NTB/NTB to RP
Enable NTB Bars
Crosslink control override
Enabled/ Disabled
DSD/USP / USD/DSP
► NIC Configuration
► PCIe Port Oprom Control
Figure 26. PCI Configuration Screen
96
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 36. Setup Utility – PCI Configuration Screen Fields
Setup Item
Options
Maximize
Memory below
4GB
Enabled
Memory
Mapped I/O
above 4GB
Memory
Mapped I/O
Size
Help Text
Comments
BIOS maximizes memory
usage below 4GB for an OS
without PAE support,
depending on the system
configuration. Only enable for
an OS without PAE support.
When this option is enabled, BIOS makes as
much memory available as possible in the 32-bit
(4GB) address space by limiting the amount of
PCI/PCIe Memory Address Space and PCIe
Extended Configuration Space to 64 buses rather
than the standard 256 buses. This is done using
the Bus Number limiting features offered by the
processor and PCH and a variably sized Memory
Mapped I/O region for the PCI Express* functions
This option should only be enabled for a 32-bit
OS without PAE capability or without PAE
enabled.
Enabled
Disabled
Enable or disable memory
mapped I/O of 64-bit PCI
devices to 4 GB or greater
address space.
When enabled, PCI/PCIe Memory Mapped I/O for
devices capable of 64-bit addressing is allocated
to address space above 4GB, in order to allow
larger allocations and avoid impacting address
space below 4GB.
Auto/1G/2G/
Sets MMIO Size: Auto >
2G(default).
When Memory Mapped I/O above 4GB option
enabled, this option sets the preserved MMIO
size as PCI/PCIe Memory Mapped I/O for devices
capable of 64-bit addressing. This option is
grayed out when Memory Mapped I/O above 4GB
option is disabled.
Onboard video controller.
When disabled, the system requires an add-in
video card for the video to be seen. When there is
no add-in video card installed, Onboard Video is
set to Enabled and grayed out so it cannot be
changed.
Disabled
4G/8G/16/32G
/64G/128G/
256G/512G
/1024G
Onboard Video
Enabled
Disabled
Warning: System video is
completely disabled if this
option is disabled and an
add-in video adapter is not
installed.
Dual Monitor
Video
NTB PCIe Port
on CPU
Socket 1
Revision 1.4
Enabled
Disabled
Transparent
Bridge/
NTB to
NTB/NTB to
RP
If enabled, both the onboard
video controller and an add-in
video adapter are enabled for
system video. The onboard
video controller becomes the
primary video device.
This option must be enabled to use an add-in
card as a secondary POST Legacy Video device
while also displaying on the Onboard Video
device.
Configures port as TB, NTBNTB, or NTB-RP.
This option selects the configuration mode of PCI
Express* Port 3A to support NTB configuration.
If there is no add-in video card in any PCIe slot
connected to CPU Socket 1, this option is set to
Disabled and grayed out and unavailable.
97
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Setup Item
Options
Enable NTB
Bars
Disabled
Enabled
Help Text
Comments
If disabled, BIOS will not
program NTB BAR size
registers.
This option allow BIOS to program NTB BAR
registers with default values when Enabled. If
disabled, BIOS will not program NTB BARs
registers and the task is left to drivers.
This option only appears when NTB PCIe Port on
CPU socket1 is not configured as ‘Transparent
Bridge’.
Crosslink
control
override
DSD/USP
USD/DSP
Configure NTB port as
DSP/USP, USD/DSP, or use
external pins.
This option configures the Crosslink configuration
of the NTB port.
This option only appears when NTB PCIe Port on
CPU socket1 is not configured as ‘Transparent
Bridge’.
NIC
Configuration
None
View/Configure NIC
information and settings.
Selection only. Select this line and press the
<Enter> key to go to the NIC Configuration group
of configuration settings.
PCIe Port
Oprom Contorl
None
View/Configure PCIe Port
Oprom control settings.
Selection only. Select this line and press the
<Enter> key to go to the PCIe Port Oprom Control
Configuration group of configuration settings.
5.4.2.10
NIC Configuration
The NIC Configuration screen allows the user to configure on board NIC port1, port2, port3, and
port4.
Advanced
NIC Configuration
98
Wake on LAN (PME)
Enabled / Disabled
PXE 1GbE Option ROM
Enabled / Disabled
PXE 10GbE Option ROM
Enabled / Disabled
FCoE 10GbE Option ROM
Enabled / Disabled
iSCSI 1GbE/10GbE Option ROM
Enabled / Disabled
Revision 1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Onboard NIC1 Type
<Onboard NIC Description – Non-InfiniBand*>
NIC1 Controller
Enabled / Disabled
NIC1 Port1
Enabled / Disabled
NIC1 Port2
Enabled / Disabled
NIC1 Port3
Enabled / Disabled
NIC1 Port4
Enabled / Disabled
NIC1 Port1 PXE
Enabled / Disabled
NIC1 Port2 PXE
Enabled / Disabled
NIC1 Port3 PXE
Enabled / Disabled
NIC1 Port4 PXE
Enabled / Disabled
NIC1 Port1 MAC Address
<MAC Address display>
NIC1 Port2 MAC Address
<MAC Address display >
NIC1 Port3 MAC Address
<MAC Address display >
NIC1 Port4 MAC Address
<MAC Address display >
IO Module 1 Type
IOM1 Port1 PXE
<IO Module Description – Non-InfiniBand*>
Enabled / Disabled
IOM1 Port2 PXE
Enabled / Disabled
IOM1 Port3 PXE
Enabled / Disabled
IOM1 Port4 PXE
Enabled / Disabled
IOM1 Port1 MAC Address
<MAC Address display >
IOM1 Port2 MAC Address
<MAC Address display >
IOM1 Port3 MAC Address
<MAC Address display >
IOM1 Port4 MAC Address
<MAC Address display >
IO Module 1 Type
<IO Module Description – InfiniBand* Only>
Revision 1.4
99
BIOS Setup Interface
Intel® Server Board S1600JP TPS
IOM1 InfiniBand* Option ROM
Enabled / Disabled
IOM1 Port1 GUID
<GUID Display>
IOM1 Port1 MAC Address
<MAC Address display >
Figure 27. NIC Configuration Screen
Table 37. Setup Utility – NIC Configuration Screen Fields
Setup Item
Wake on LAN
(PME)
Options
Enabled
Disabled
PXE 1GbE
Option ROM
Enabled
Disabled
Help Text
Comments
Enables or disables
PCI PME function for
Wake on LAN
capability from LAN
adapters.
Enables/disables PCI/PCIe PME# signal to generate
Power Management Events (PME) and ACPI Table
entries required for Wake on LAN (WOL). However, note
that this will enable WOL only with an ACPI-capable
Operating System which has the WOL function enabled.
Enable/Disable
Onboard/IOM NIC PXE
Option ROM Load.
This selection is to enable/disable the 1GbE PXE Option
ROM that is used by all Onboard and IO Module 1 GbE
controllers.
This option is grayed out and not accessible if the iSCSI
Option ROM is enabled. It can co-exist with the 10 GbE
PXE Option ROM, the 10 GbE FCoE Option ROM, or
with an InfiniBand* controller Option ROM.
If the 1GbE PXE Option ROM is disabled, and no other
Option ROM is enabled, the system cannot perform a
Network Boot and cannot respond for Wake-on-LAN.
This 1GbE PXE option does not appear unless there is a
1 GbE NIC installed in the system as an Onboard or IO
Module NIC.
100
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
PXE 10GbE
Option ROM
Options
Enabled
Disabled
BIOS Setup Interface
Help Text
Enable/Disable
Onboard/IOM NIC PXE
Option ROM Load.
Comments
This selection is to enable/disable the 10GbE PXE
Option ROM that is used by all Onboard and IO Module
10 GbE controllers.
This option is grayed out and not accessible if the iSCSI
Option ROM is enabled or the 10 GbE FCoE Option
ROM is enabled. It can co-exist with the 1 GbE PXE
Option ROM or with an InfiniBand* controller Option
ROM.
If the 10GbE PXE Option ROM is disabled, and no other
Option ROM is enabled, the system cannot perform a
Network Boot and cannot respond for Wake-on-LAN.
This 10GbE PXE option does not appear unless there is
a 10 GbE NIC installed in the system as an Onboard or
IO Module NIC.
FCoE 10GbE
Option ROM
Enabled
Disabled
Enable/Disable
Onboard/IOM NIC
FCoE Option ROM
Load.
This selection is to enable/disable the 10GbE FCoE
Option ROM that is used by all Onboard and IO Module
10 GbE controllers capable of FCoE support. At the
®
present time, only the Intel 82599 10 Gigabit SFP+ NIC
supports FCoE for this family of server boards.
This option is grayed out and not accessible if the 10GbE
PXE Option ROM is enabled or if the iSCSI Option ROM
is enabled. It can co-exist with the 1GbE PXE Option
ROM or with an InfiniBand* controller Option ROM.
If the FCoE Option ROM is disabled, and no other Option
ROM is enabled, the system cannot perform a Network
Boot and cannot respond for Wake-on-LAN.
This FCoE option does not appear unless there is a
FCoE-capable 10GbE NIC installed in the system as an
Onboard or IO Module NIC.
iSCSI
1GbE/10GbE
Option ROM
Enabled
Disabled
Enable/Disable
Onboard/IOM NIC
iSCSI Option ROM
Load.
This selection is to enable/disable the iSCSI Option ROM
that is used by all Onboard and IO Module 1 GbE and 10
GbE controllers.
This option is grayed out and not accessible if the 1 GbE
or 10GbE PXE Option ROM is enabled or if the 10 GbE
FCoE Option ROM is enabled. It can co-exist with an
InfiniBand* controller Option ROM.
If the iSCSI Option ROM is disabled, and no other Option
ROM is enabled, the system cannot perform a Network
Boot and cannot respond for Wake-on-LAN.
This iSCSI option does not appear unless there is an
iSCSI -capable NIC installed in the system as an
Onboard or IO Module NIC.
Revision 1.4
101
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Setup Item
Options
Help Text
Comments
Onboard NIC1
Type
Onboard
NIC
Description
None.
Information only. This is a display showing which NIC is
available as Network Controllers integrated into the
baseboard. Onboard NIC will be followed by a section
including a group of options that are specific to the type
of NIC.
NIC1 Controller
Enabled
Disabled
Enable/Disable
Onboard Network
Controller.
This will completely disable Onboard Network Controller
NIC1, along with all included NIC Ports and their
associated options. That controller’s NIC Ports, Port PXE
options, and Port MAC Address displays will not appear.
Ethernet controllers on IO Modules do not have a
disabling function that can be controlled by BIOS, so
there is no corresponding controller enable/disable option
for an IOM Ethernet controller.
NIC1 Port x
Enabled
Disabled
Enable/Disable NIC1
Port x
This will enable or disable Port <x, x = 1-4> of Onboard
Network Controller 1, including associated Port PXE
options. The NIC 1 Port x PXE option and MAC Address
display will not appear when that port is disabled.
The associated port enable/disable options will not
appear when NIC 1 is disabled.
Only ports which actually exist for a particular NIC will
appear in this section. That is, Port1-Port4 will appear for
a quad-port NIC, Port1-Port2 will appear for a dual-port
NIC.
Network controllers installed on an IO Module do not
have a port disabling function that is controlled by BIOS,
so there are no corresponding options for IO Module
NICs.
102
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
NIC1 Port x
PXE
Options
Enable
BIOS Setup Interface
Help Text
Enable/Disable NIC 1
Port x PXE Boot
Disable
Comments
This will enable or disable PXE Boot capability for Port<x,
x = 1-4> of Onboard NIC 1.
This option will not appear for ports on a NIC which is
disabled, or for individual ports when the corresponding
NIC Port is disabled.
Only ports which actually exist for NIC1 will appear in this
section. That is, Port1-Port4 will appear for a quad-port
NIC, Port1-Port2 will appear for a dual-port NIC.
The default state of each Port PXE Boot option is
Enabled, if the corresponding PXE Boot OPROM of the
same speed is Enabled. If a PXE Boot OPROM for 1
GbE or 10 GbE changes from Disabled to Enabled, then
the Port PXE Boot option becomes Enabled for all ports
of that speed.
If the PXE Boot OPROM for1 GbE NICs or 10 GbE NICs
is disabled, PXE Boot will be disabled and grayed out as
unchangeable for all ports on NIC1 of that same speed.
Conversely, if PXE Boot is disabled for all ports of a
given speed, the corresponding PXE Option ROM will be
disabled but not grayed out since it could be selected.
NIC 1 Port x
MAC Address
Mac Address None
Display
Information only. 12 hex digits of the MAC address of
Port<x, x = 1-4> of the NIC1.
This display will appear only for ports which actually exist
on the corresponding Network Controller. If the Network
Controller or port is disabled, the port MAC Address will
not appear.
IO Module 1
Type
IO Module
Description
None
Information only. This is a display showing which Network
Controllers on IO Modules are installed on the
baseboard. Each of these IO Module NICs will be
followed by a section including a group of options that are
specific to the type of NIC, either as an Ethernet
controller or an InfiniBand* controller.
IO Module Type and following options section will only
appear when an IO Module is installed,
Revision 1.4
103
BIOS Setup Interface
Setup Item
IOM1 Portx
PXE
Intel® Server Board S1600JP TPS
Options
Enabled
Disabled
Help Text
Enable/Disable IOM
NIC Port PXE Boot
Comments
This will enable or disable PXE Boot capability for Port<x,
x = 1-4> of IO Module 1.
Only ports which actually exist for a particular IOM will
appear in this section. That is, Port1-Port4 will appear for
a quad-port NIC, Port1-Port2 will appear for a dual-port
NIC, and only Port1 will appear for a single-port NIC.
The default state of each Port PXE Boot option is
Enabled, if the corresponding PXE Boot OPROM of the
same speed is Enabled. If a PXE Boot OPROM for 1
GbE or 10 GbE changes from Disabled to Enabled, then
the Port PXE Boot option becomes Enabled for all ports
of that speed.
If the PXE Boot OPROM for1 GbE NICs or 10 GbE NICs
is disabled, PXE Boot will be disabled and grayed out as
unchangeable for all ports on IO Modules of that same
speed.
Conversely, if PXE Boot is disabled for all ports of a
given speed, the corresponding PXE Option ROM will be
disabled but not grayed out since it could be selected.
IOM1 Portx
MAC Address
Mac Address None
Display
Information only. 12 hex digits of the MAC address of
Port1- Port4 of the IOM1.
IOM1
InfiniBand*
Option ROM
Enabled
Disabled
This option will control whether the associated InfiniBand*
Controller Option ROM is executed by BIOS during
POST. This will also control whether the InfiniBand*
controller FlexBoot program appears in the list of
bootable devices.
Enable/Disable
InfiniBand* Controller
Option ROM and
FlexBoot.
This option only appears for IO Module InfiniBand*
controllers. It does not appear for Ethernet controllers.
IOM1 Port1
GUID
GUID
Display
None
Information only. 16 hex digits of the Port1 GUID of the
InfiniBand* controller for IOM1.
5.4.2.11
PCIe Port Oprom Control
The PCIe Root Port Expansion ROM configuration screen allows user to configure the
Expansion ROM(Oprom) dispatching of the PCIe devices connected to the IIO PCIe root port
during the BIOS POST.
104
Revision
1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
To access this screen from the Main screen, select Advanced > PCI Configuration > PCIe
Port Oprom Contrl. To move to another screen, press the <Esc> key to return to the PCI
Configuration screen, if necessary press the <Esc> key again to return to the Advanced screen,
then select the desired screen.
Advanced
PCIe Port Oprom Control
CPU socket 1
Enabled / Disabled
PCIe Port 1a OpROM control
Enabled / Disabled
PCIe Port 1b OpROM control
Enabled / Disabled
PCIe Port 2a OpROM control
Enabled / Disabled
PCIe Port 2b OpROM control
Enabled / Disabled
PCIe Port 2c OpROM control
Enabled / Disabled
PCIe Port 2d OpROM control
Enabled / Disabled
PCIe Port 3a OpROM control
Enabled / Disabled
PCIe Port 3b OpROM control
Enabled / Disabled
PCIe Port 3c OpROM control
Enabled / Disabled
PCIe Port 3d OpROM control
Figure 28 PCIe Port Oprom Control Screen
Table 38 Setup Utility – PCIe Port Oprom Control Screen Fields
Setup
Item
PCIe Port
xy OpROM
control
Revision 1.4
Options
Enabled
Disabled
Help Text
Comments
Enable or Disable Oprom dispatching of the Disabling Oprom dispatching of the PCIe
PCIe Devices on this Root Port.
Devices on this Root Port will save the
limited memory space for PCIe Oprom.
105
BIOS Setup Interface
5.4.2.12
Intel® Server Board S1600JP TPS
Serial Port Configuration
The Serial Port Configuration screen allows the user to configure the Serial A [COM 1] ports.
To access this screen from the Main screen, select Advanced > Serial Port Configuration. To
move to another screen, press the <Esc> key to return to the Advanced screen, then select the
desired screen.
Advanced
Serial Port Configuration
Serial A Enable
Enabled/Disabled
Address
3F8h/2F8h/3E8h/2E8h
IRQ
3 or 4
Figure 29. Serial Port Configuration Screen
Table 39. Setup Utility – Serial Ports Configuration Screen Fields
Setup
Item
Options
Help Text
Comments
Serial A
Enable
Enabled
Disabled
Enable or Disable Serial port A.
Serial Port A can be used for either Serial
Over LAN or Serial Console Redirection.
Address
3F8h
2F8h
Select Serial port A base I/O address.
Legacy I/O port address. This field should
not appear when Serial A port
enable/disable does not appear.
Select Serial port A interrupt request (IRQ)
line.
Legacy IRQ. This field should not appear
when Serial A port enable/disable does
not appear.
3E8h
2E8h
IRQ
3
4
106
Revision
1.4
Intel® Server Board S1600JP TPS
5.4.2.13
BIOS Setup Interface
USB Configuration
The USB Configuration screen allows the user to configure the USB controller options.
To access this screen from the Main screen, select Advanced > USB Configuration. To move
to another screen, press the <Esc> key to return to the Advanced screen, then select the
desired screen.
Advanced
USB Configuration
Detected USB Devices
< Number of USB devices detected in system >
USB Controller
Enabled/Disabled
Legacy USB Support
Enabled/Disabled/Auto
Port 60/64 Emulation
Enabled/Disabled
Make USB Devices Non-Bootable
Enabled/Disabled
USB Mass Storage Device Configuration
Device Reset timeout
10 seconds/20 seconds/30 seconds/40 seconds
Mass Storage Devices:
<Mass storage devices one line per device>
Auto/Floppy/Forced FDD/Hard Disk/CD-ROM
Figure 30. USB Configuration Screen
Revision 1.4
107
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Table 40. Setup Utility – USB Controller Configuration Screen Fields
Setup Item
Options
Detected USB
Devices
Number of
USB devices
detected in
system
Help Text
Comments
None
Information only.
Displays the total number
of USB devices of all
types which have been
detected in POST.
Note: There is one USB
keyboard and one USB
mouse detected from the
BMC KVM function under
this item, even if no USB
devices are connected to
the system.
USB Controller
Legacy USB
Support
Enabled
Disabled
Enabled
Disabled
Auto
[Enabled] - All onboard USB controllers are turned
on and accessible by the OS.
[Disabled] - All onboard USB controllers are turned
off and inaccessible by the OS.
When the USB
controllers are Disabled,
there is no USB IO
available for either POST
or the OS. In that case,
all following fields on this
screen are grayed out
and inactive.
Enables Legacy USB support. AUTO option
disables legacy support if no USB devices are
connected. Disable option will only keep USB
Keyboard devices available for EFI applications.
When Legacy USB
Support is Disabled, USB
devices are available
only through OS drivers.
If the USB controller
setting is Disabled, this
field is grayed out and
inactive.
Port 60/64
Emulation
Enabled
Disabled
Enables I/O port 60h/64h emulation support.
This may be needed for legacy USB keyboard
support when using an OS that is USB unaware.
If the USB controller
setting is Disabled, this
field is grayed out and
inactive.
Make USB
Devices NonBootable
Enabled
Disabled
Exclude USB in Boot Table.
This is a security option.
When Disabled, the
system cannot be booted
directly to a USB device
of any kind. USB Mass
Storage devices may still
be used for data storage.
[Enabled] - This removes all USB Mass Storage
devices as Boot options.
[Disabled] - This allows all USB Mass Storage
devices as Boot options.
If the USB controller
setting is Disabled, this
field is grayed out and
inactive.
108
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Device Reset
timeout
Options
10 seconds
20 seconds
30 seconds
BIOS Setup Interface
Help Text
USB Mass Storage device Start Unit command
timeout.
Setting to a larger value provides more time for a
mass storage device to be ready, if needed.
Comments
If the USB controller
setting is Disabled, this
field is grayed out and
inactive.
40 seconds
Mass Storage
Devices
Auto
Floppy
ForcedFDD
[Auto] - USB devices less than 530 MB are
emulated as floppies.
[Forced FDD] - HDD formatted drive is emulated as
an FDD (For example, ZIP drive).
Hard Disk
CD-ROM
This field is hidden if no
USB Mass Storage
devices are detected.
This setup screen can
show a maximum of eight
USB Mass Storage
devices on the screen. If
more than eight devices
are installed in the
system, the ‘USB
Devices Enabled’
displays the correct count
but only the first eight
devices discovered are
displayed in this list.
If the USB controller
setting is Disabled, this
field is grayed out and
inactive.
5.4.2.14
System Acoustic and Performance Configuration
The System Acoustic and Performance Configuration screen allows the user to configure the
thermal control behavior of the system with respect to what parameters are used in the system’s
Fan Speed Control algorithms.
To access this screen from the Main screen, select Advanced > System Acoustic and
Performance Configuration. To move to another screen, press the <Esc> key to return to the
Advanced screen, then select the desired screen.
Revision 1.4
109
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Advanced
System Acoustic and Performance Configuration
Set Throttling Mode
Auto/DCLTT/SCLTT/SOLTT
Altitude
300m or less/301m-900m/901m – 1500m/Higher than
1500m
Set Fan Profile
Performance, Acoustic
Fan PWM Offset
[0 – 100, 0 is default]
Quiet Fan Idle Mode
Enabled/Disabled
Figure 31. System Acoustic and Performance Configuration
110
Revision
1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 41. Setup Utility – System Acoustic and Performance Configuration Screen Fields
Setup Item
Set Throttling
Mode
Options
Auto
DCLTT
SCLTT
SOLTT
Help Text
Sets Thermal Throttling mode for
memory, to control fans and DRAM
power as needed to control DIMM
temperatures.
[Auto] –BIOS selects mode.
[DCLTT] – Dynamic Closed Loop
Thermal Throttling
[SCLTT] – Static Closed Loop
Thermal Throttling
[SOLTT] – Static Open Loop
Thermal Throttling
Comments
The Thermal Throttling Mode chosen
reflects whether the DIMMs have
Temperature Sensors (TSOD), and
whether the chassis is an Intel®
chassis for which thermal data are
available. Note that this is for thermal
throttling only, independent of any
controls imposed for the purpose of
power limiting.
DCLTT is the expected mode for a
®
board in an Intel chassis with inlet
and outlet air temperature sensors
and TSOD. The firmware can update
the offset registers for closed loop
during runtime, as BIOS sends the
dynamic CLTT offset temperature
data.
SCLTT would be used with an OEM
chassis and DIMMs with TSOD. The
firmware does not change the offset
registers for closed loop during
runtime, although the Management
Engine can do so.
SOLTT is intended for a system with
UDIMMs which do not have TSOD.
The thermal control registers are
configured during POST, and the
firmware does not change them.
Altitude
300m or less
[300m or less] (980ft or less)
301m-900m
901m-1500m
Optimal performance setting near
sea level.
Higher than 1500m [301m - 900m] (980ft - 2950ft)
This option sets an altitude value in
order to choose a Fan Profile that is
optimized for the air density at the
current altitude at which the system is
installed.
Optimal performance setting at
moderate elevation.
[901m – 1500m] (2950ft – 4920ft)
Optimal performance setting at high
elevation.
[Higher than 1500m] (4920ft or
greater)
Optimal performance setting at the
highest elevations.
Revision 1.4
111
BIOS Setup Interface
Setup Item
Set Fan
Profile
Options
Performance
Acoustics
Intel® Server Board S1600JP TPS
Help Text
Comments
[Performance] - Fan control
provides primary system cooling
before attempting to throttle
memory.
This option allows the user to choose
a Fan Profile that is optimized for
maximizing performance or for
minimizing acoustic noise.
[Acoustic] - The system will favor
using throttling of memory over
boosting fans to cool the system if
thermal thresholds are met.
When Performance is selected, the
thermal conditions in the system are
controlled by raising fan speed when
necessary to raise cooling
performance. This provides cooling
without impacting system
performance, but may impact system
acoustic performance – fans running
faster are typically louder.
When Acoustic is selected, then rather
than increasing fan speed for
additional cooling, the system will
attempt first to control thermal
conditions by throttling memory to
reduce heat production. This regulates
the system’s thermal condition without
changing the acoustic performance,
but throttling memory may impact
system performance.
Fan PWM
Offset
Entry Field 0 –
100, 0 is default
Valid Offset 0 - 100. This number is
added to the calculated PWM value
to increase Fan Speed.
This is a percentage by which the
calculated fan speed will be increased.
The user can apply positive offsets
that result in increasing the minimum
fan speeds.
Quiet Fan Idle
Mode
Disabled
Enabled
Enabling this option allows the
system fans to operate in Quiet
‘Fan off’ mode while still
maintaining sufficient system
cooling. In this mode, fan sensors
become unavailable and cannot be
monitored. There will be limited fan
related event generation.
When enabled, this option allows fans
to idle or turn off when sufficient
thermal margin is available,
decreasing the acoustic noise
produced by the system and
decreasing system power
consumption. Fans will run as needed
to maintain thermal control. The actual
decrease in fan speed depends on the
system thermal loading, which in turn
depends on system configuration and
workload.
While Quiet Fan Idle Mode is
engaged, fan sensors become
unavailable and are not monitored by
the BMC.
112
Revision
1.4
Intel® Server Board S1600JP TPS
5.4.2.15
BIOS Setup Interface
Security Screen (Tab)
The Security screen allows the user to enable and set the user and administrative password
and to lock out the front panel buttons so that they cannot be used. This screen also allows the
user to enable and activate the Trusted Platform Module (TPM) security settings on those
boards that support TPM.
To access this screen from the Main screen or other top-level Tab screen, press the right or left
arrow keys to traverse the tabs at the top of the Setup screen until the Security screen
is selected.
Main
Advanced
Security
Server Management
Boot Options
Boot Manager
Administrator Password Status
<Installed/Not Installed>
User Password
<Installed/Not Installed>
Set Administrator Password
[123aBcD]
Set User Password
[123aBcD]
Power ON Password
Enabled/Disabled
Front Panel Lockout
Enabled/Disabled
TPM State
<Displays current TPM Device State>
TPM Administrative Control
No Operation/Turn On/Turn Off/Clear Ownership
Figure 32. Security Screen
Table 42. Setup Utility – Security Configuration Screen Fields
Setup Item
Administrator
Password Status
Options
Installed
Help Text
None
Comments
Information only. Indicates the status of
the administrator password.
Not Installed
Revision 1.4
113
BIOS Setup Interface
Setup Item
User Password
Status
Intel® Server Board S1600JP TPS
Options
Installed
Help Text
Comments
None
Information only. Indicates the status of
the user password.
Administrator password
is used if Power On
Password is enabled
and to control change
access in BIOS Setup.
Length is 1-14
characters. Case
sensitive alphabetic,
numeric, and special
characters !@#$%^&*()_+=? are allowed.
Note: Administrator
password must be set
in order to use the User
account.
This password controls “change”
access to Setup. The Administrator has
full access to change settings for any
Setup options, including setting the
Administrator and User passwords.
Not Installed
Set Administrator
Password
Entry Field – 0-14
characters
When Power On Password protection is
enabled, the Administrator password
may be used to allow the BIOS to
complete POST and boot the system.
Deleting all characters in the password
entry field removes a password
previously set. Clearing the
Administrator Password also clears the
User Password.
If invalid characters are present in the
password entered, it will not be
accepted, and there will be popup error
message:
Password entered is not valid. Only
case sensitive alphabetic, numeric and
special characters !@#$%^&*()-_+=?
are allowed.
The Administrator and User passwords
must be different. If the password
entered is the same as the User
password, it will not be accepted, and
there will be popup error message:
Password entered is not valid.
Administrator and User passwords
must be different.
Strong passwords are encouraged,
although not mandatory. If a password
is entered which does not meet the
“Strong Password” criteria, there will be
a popup warning message:
Warning – A Strong Password should
include at least one each case sensitive
alphabetic, numeric, and special
character. Length should be 8 to 14
characters.
114
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Set User
Password
Options
Entry Field – 0-14
characters
BIOS Setup Interface
Help Text
User password is used
if Power On Password
is enabled and to allow
restricted access to
BIOS Setup. Length is
1-14 characters. Case
sensitive alphabetic,
numeric, and special
characters !@#$%^&*()_+=? are allowed.
Note: Removing the
administrator password
also removes the user
password.
Power ON
Password
Enabled
Disabled
Enable Power On
Password support. If
enabled, password
entry is required in
order to boot the
system.
Comments
The User password is available only if
the Administrator Password has been
installed. This option protects Setup
settings as well as boot choices. The
User Password only allows limited
access to the Setup options, and no
choice of boot devices.
When Power On Password protection
is enabled, the User password may be
used to allow the BIOS to complete
POST and boot the system.
The password format and entry rules
and popup error and warning message
are the same for the User password as
for the Administrator password (see
above).
When Power On Password security is
enabled, the system will halt soon after
power on and the BIOS will ask for a
password before continuing POST and
booting. Either the Administrator or
User password may be used.
If an Administrator password has not
been set, this option will be grayed out
and unavailable. If this option is
enabled and the Administrator
password is removed, that will also
disable this option.
Front Panel
Lockout
Revision 1.4
Enabled
Disabled
If enabled, locks the
power button OFF
function and the reset
and NMI Diagnostic
Interrupt buttons on the
system’s front panel. If
[Enabled] is selected,
power off and reset
must be controlled
through a system
management interface,
and the NMI Diagnostic
Interrupt is not
available.
None
115
BIOS Setup Interface
Setup Item
TPM State
Intel® Server Board S1600JP TPS
Options
<Displays current TPM
Device State>
Help Text
None
Comments
Information only. Shows the current
TPM device state.
May be:
A Disabled TPM device does not
execute commands that use the TPM
functions and TPM security operations
are not available.
Enabled & Activated
Enabled & Deactivated
An Enabled & Deactivated TPM is in
the same state as a disabled TPM,
except that setting of the TPM
ownership is allowed if it is not present
already.
Disabled & Activated
Disabled & Deactivated
An Enabled & Activated TPM executes
all commands that use the TPM
functions and TPM security operations
are also available.
Note: This option appears only on
boards equipped with a TPM.
TPM
Administrative
Control
No Operation
Turn On
[No Operation] - No
changes to current
state.
Turn Off
Clear Ownership
[Turn On] - Enables and
activates TPM.
Any Administrative Control operation
selected will require the system to
perform a Hard Reset in order to
become effective.
Note: This option appears only on
boards equipped with a TPM.
[Turn Off] - Disables
and deactivates TPM.
[Clear Ownership] Removes TPM
ownership & returns
TPM to factory default
state.
Note: Setting returns to
[No Operation] on every
boot.
5.4.2.16
Server Management Screen (Tab)
The Server Management screen allows the user to configure several server management
features. This screen also provides an access point to the screens for configuring console
redirection, displaying system information, and controlling the BMC LAN configuration.
To access this screen from the Main screen or other top-level Tab screen, press the right or left
arrow keys to traverse the tabs at the top of the Setup screen until the Server Management
screen is selected.
116
Revision
1.4
Intel® Server Board S1600JP TPS
Main
Advanced
BIOS Setup Interface
Security
Server Management
Boot Options
Boot Manager
Assert NMI on SERR
Enabled / Disabled
Assert NMI on PERR
Enabled / Disabled
PCIe AER Support
Enabled / Disabled
Reset on CATERR
Enabled / Disabled
Reset on ERR2
Enabled / Disabled
Resume on AC Power Loss
Stay Off / Last state / Power On
Power Restore Delay
Disabled/Auto/Fixed
Power Restore Delay Value
25
Clear System Event Log
Enabled / Disabled
FRB-2 Enable
Enabled / Disabled
OS Boot Watchdog Timer
Enabled / Disabled
OS Boot Watchdog Timer Policy
Power off / Reset
OS Boot Watchdog Timer Timeout
5 minutes / 10 minutes / 15 minutes / 20 minutes
Plug and Play BMC Detection
Enabled / Disabled
EuP LOT6 Off-Mode
Enabled / Disabled
► Console Redirection
► System Information
Revision 1.4
117
BIOS Setup Interface
Intel® Server Board S1600JP TPS
► BMC LAN Configuration
Figure 33. Server Management Screen
Table 43. Setup Utility – Server Management Configuration Screen Fields
Setup Item
Assert NMI on
SERR
Options
Enabled
Disabled
Help Text
Comments
On SERR, generate an NMI and log
an error.
Note: [Enabled] must be selected for
the Assert NMI on PERR setup
option to be visible.
Assert NMI on
PERR
Enabled
Disabled
On PERR, generate an NMI and log
an error.
Note: This option is only active if the
Assert NMI on SERR option is
[Enabled] selected.
PCIe AER Support
Enabled
Disabled
[Enabled] – PCIe AER (Advanced
Error Reporting) is enabled.
[Disabled] – PCIe AER is disabled.
All PCIe AER errors will be masked
once PCIe AER is disabled.
Reset on CATERR
Enabled
Disabled
When enabled system gets reset
upon encountering Catastrophic
Error (CATERR); when disabled
system does not get reset on
CATERR.
This option allows the system to
generate an NMI when an SERR
occurs, which is a method Legacy
Operating System error handlers
may use instead of processing a
Machine Check.
This option allows the system to
generate an NMI when a PERR
occurs, which is a method Legacy
Operating System error handlers
may use instead of processing a
Machine Check.
This option allows the system to
monitor and handle PCIe AER
errors on PCIe devices with PCIe
AER support. But as PCIe AER is
described in PCI Express* Base
Specification, any third party
software or OS could override this
BIOS policy and take ownership of
PCIe AER handling after BIOS
POST.
This option controls whether the
system will be reset when the
“Catastrophic Error” CATERR#
signal is held asserted, rather than
just pulsed to generate an SMI. This
indicates that the processor has
encountered a fatal hardware error.
Note: If “Reset on CATERR” is
Disabled, this can result in a system
hang for certain error conditions,
possibly with the system unable to
update the System Status LED or
log an error to the SEL before
hanging.
118
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Reset on ERR2
Options
Enabled
Disabled
BIOS Setup Interface
Help Text
When enabled system gets reset
upon encountering ERR2 (Fatal
error); when disabled system does
not get reset on ERR2.
Comments
This option controls whether the
system will be reset if the BMC’s
ERR2 Monitor times out, that is, the
ERR2 signal has been continuously
asserted long enough to indicate
that the SMI Handler is not able to
service the condition.
Note: If “Reset on ERR2” is
Disabled, this can result in a system
hang for certain error conditions,
possibly with the system unable to
update the System Status LED or
log an error to the SEL before
hanging.
Resume on AC
Power Loss
Stay Off
Last state
Power on
System action to take on AC power
loss recovery.
[Stay Off] - System stays off.
[Last State] - System returns to the
same state before the AC power
loss.
[Power On] - System powers on.
This option controls the policy that
the BMC will follow when AC power
is restored after an unexpected
power outage. The BMC will either
hold DC power off or always turn it
on to boot the system, depending on
this setting – and in the case of Last
State, depending on whether the
power was on and the system was
running before the AC power went
off.
When this setting is changed in
Setup, the new setting will be sent
to the BMC. However, the BMC
maintains (“owns”) this Power
Restore Policy setting, and it can be
changed independently with an IPMI
command to the BMC. BIOS gets
this setting from the BMC early in
POST, and also for the Setup
Server Management screen.
Note: System will automatically
power on after when AC is applied
doing a CMOS clear because this
option will not take effect at this
situation.
Revision 1.4
119
BIOS Setup Interface
Setup Item
Power Restore
Delay
Intel® Server Board S1600JP TPS
Options
Disabled
Auto
Fixed
Help Text
Comments
Allows a delay in powering up after a
power failure, to reduce peak power
requirements. The delay can be fixed
or automatic between 25-300
seconds.
When the AC power resume policy
(above) is either Power On or Last
State, this option allows a delay to
be taken after AC power is restored
before the system actually begins to
power up. This delay can be either a
fixed time or an “automatic” time,
where “automatic” means that the
BIOS will select a randomized delay
time of 25-300 seconds when it
sends the Power Restore Delay
setting to the BMC.
This option will be grayed out and
unavailable when the AC power
resume policy is Stay Off.
The Power Restore Delay setting is
maintained by BIOS. This setting
does not take effect until a reboot is
done. Early in POST, the Power
Restore Policy is read from the
BMC, and if the policy is Power On
or Last State, the delay settings are
sent to the BMC.
Bear in mind that even if the Power
Restore Delay is Disabled, there will
still be a delay of about 20 seconds
while the BMC itself boots up after
AC power is restored.
Note: This Power Restore Delay
option applies only to powering on
when AC is applied. It has no effect
on powering the system up using
the Power Button on the Front
Panel. A DC power on using the
Power Button is not delayed.
The purpose of this delay is to avoid
having all systems draw “startup
surge” power at the same time.
Different systems or racks of
systems can be set to different
delay times to spread out the startup
power draws. Alternatively, all
systems can be set to Automatic,
and then each system will wait for a
random period before powering up.
120
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Power Restore
Delay Value
Options
BIOS Setup Interface
Help Text
Comments
Entry Field 25 Fixed time period 25-300 seconds for When the power restore policy is
– 300, 25 is
Power Restore Delay
Power On or Last State, and the
default
Power Restore Delay selection is
Fixed, this field allows for specifying
how long in seconds that fixed delay
will be.
When the Power Restore Delay is
Disabled or Auto, this field will be
grayed out and unavailable.
The Power Restore Delay Value
setting is maintained by BIOS. This
setting does not take effect until a
reboot is done. Early in POST, the
Power Restore Policy is read from
the BMC, and if the policy is Power
On or Last State, the delay settings
are sent to the BMC. When the
Power Restore Delay setting is
Fixed, this delay value is used to
provide the length of the delay.
Clear System Event
Log
Enabled
Disabled
If enabled, clears the System Event
Log. All current entries will be lost.
Note: This option is reset to
[Disabled] after a reboot.
FRB-2 Enable
Enabled
Disabled
Fault Resilient Boot (FRB).
BIOS programs the BMC watchdog
timer for approximately 6 minutes. If
BIOS does not complete POST
before the timer expires, the BMC
will reset the system.
This option sends a message to the
BMC to request it to clear the
System Event Log. The log will be
cleared, and then the “Clear” action
itself will be logged as an event.
This gives the user a time/date for
when the log was cleared.
This option controls whether the
system will be reset if the BMC
Watchdog Timer detects what
appears to be a hang during POST.
When the BMC Watchdog Timer is
purposed as an FRB 2 timer, it is
initially set to allow six minutes for
POST to complete.
However, the FRB 2 Timer is
suspended during times when some
lengthy operations are in progress,
like executing Option ROMS, during
Setup, and when BIOS is waiting for
a password or for input to the F6
BBS Boot Menu. The FRB 2 Timer
is also suspended while POST is
paused with the <Pause> key.
Revision 1.4
121
BIOS Setup Interface
Setup Item
O/S Boot Watchdog
Timer
Intel® Server Board S1600JP TPS
Options
Enabled
Disabled
Help Text
Comments
If enabled, the BIOS programs the
watchdog timer with the timeout
value selected. If the OS does not
complete booting before the timer
expires, the BMC resets the system
and an error is logged.
®
Requires OS support or Intel
Management Software.
This option controls whether the
system will set the BMC Watchdog
to detect an apparent hang during
OS boot. BIOS sets the timer before
starting the OS bootstrap load
procedure. If the OS Load
Watchdog Timer times out, then
presumably the OS failed to boot
properly.
If the OS does boot up successfully,
it must be aware of the OS Load
Watchdog Timer and immediately
turn it off before it expires. The OS
may turn off the timer, or more often
the timer may be repurposed as an
OS Watchdog Timer to protect
against runtime OS hangs.
Unless the OS does have timeraware software to support the OS
Load Watchdog Timer, the system
will be unable to boot successfully
with the OS Load Watchdog Timer
enabled. When the timer expires
without having been reset or turned
off, the system will either reset or
power off repeatedly.
O/S Boot Watchdog
Timer Policy
Power Off
Reset
If the OS boot watchdog timer is
enabled, this is the system action
taken if the watchdog timer expires.
This option is grayed out and
unavailable when the O/S Boot
Watchdog Timer is disabled.
[Reset] - System performs a reset.
[Power Off] - System powers off.
O/S Boot Watchdog
Timer Timeout
5 minutes
10 minutes
15 minutes
If the OS watchdog timer is enabled,
this is the timeout value used by the
BIOS to configure the watchdog
timer.
This option is grayed out and
unavailable when the O/S Boot
Watchdog Timer is disabled.
If enabled, the BMC is detectable by
OSs that support plug and play
loading of an IPMI driver. Do not
enable if your OS does not support
this driver.
This option controls whether the OS
Server Management Software will
be able to find the BMC and
automatically load the correct IPMI
support software for it. If your OS
does not support Plug & Play for the
BMC, you will not have the correct
IPMI driver software loaded.
20 minutes
Plug and Play BMC
Detection
Enabled
Disabled
122
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
BIOS Setup Interface
Options
EuP LOT6 OffMode
Enabled
Disabled
Help Text
Enable/disable Ecodesign EuP LOT6
“Deep Sleep” Off-Mode for near-zero
energy use when powered off.
Comments
This option controls whether the
system goes into “Deep Sleep” or
more conventional S5 “Soft-Off”
when powered off. “Deep Sleep”
state uses less energy than S5 but
S5 can start up faster and can allow
a Wake on LAN action (which
cannot be done from a Deep Sleep
state).
This option will not appear on
platforms which do not support EuP
LOT6 Off-Mode.
Console
Redirection
None
View/Configure console redirection
information and settings.
Selection only. Select this line and
press the <Enter> key to go to the
Console Redirection group of
configuration settings.
System Information
None
View system information
Selection only. Select this line and
press the <Enter> key to go to the
System Information group of
configuration settings.
BMC LAN
Configuration
None
View/Configure BMC LAN channel
and user settings.
Selection only. Select this line and
press the <Enter> key to go to the
BMC LAN Configuration group of
configuration settings.
5.4.2.17
Console Redirection
The Console Redirection screen allows the user to enable or disable Console Redirection for
Remote Management, and to configure the connection options for this feature.
To access this screen from the Main screen, select Server Management > Console
Redirection. To move to another screen, press the <Esc> key to return to the Server
Management screen, then select the desired screen.
Revision 1.4
123
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Server Management
Console Redirection
Console Redirection
Disabled / Serial Port A
Flow Control
None / RTS/CTS
Baud Rate
9.6k / 19.2k / 38.4k / 57.6k / 115.2k
Terminal Type
PC-ANSI / VT100 / VT100+ / VT-UTF8
Legacy OS Redirection
Disabled / Enabled
Terminal Resolution
80x24 / 100x31
Figure 34. Console Redirection Screen
Table 44. Setup Utility – Console Redirection Configuration Fields
Setup Item
Console
Redirection
Options
Disabled
Serial Port A
Help Text
Comments
Console redirection allows a serial port to
be used for server management tasks.
[Disabled] - No console redirection.
[Serial Port A] - Configure serial port A for
console redirection.
Enabling this option disables the display of
the Quiet Boot logo screen during POST.
Serial Console Redirection can use
Serial Port A. If SOL is also going to
be configured, note that SOL is only
supported through Serial Port A.
When Console Redirection is set to
Disabled, all other options on this
screen will be grayed out and
unavailable.
Only Serial Ports which are Enabled
should be available to choose for
Console Redirection. If Serial A is
set to Enabled, then Console
Redirection will be forced to
Disabled, and grayed out as
inactive. In that case, all other
options on this screen will also be
grayed.
Flow Control
None
RTS/CTS
Flow control is the handshake protocol.
Setting must match the remote terminal
application.
124
Flow control is necessary only when
there is a possibility of data
overrun. In that case the Request To
Send/Clear to Send (RTS/CTS)
hardware handshake is a relatively
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Options
BIOS Setup Interface
Help Text
[None] - Configure for no flow control.
[RTS/CTS] - Configure for hardware flow
control.
Baud Rate
9600
19.2K
Serial port transmission speed. Setting
must match the remote terminal
application.
38.4K
57.6K
PC-ANSI
VT100
VT100+
conservative protocol which can
usually be configured at both ends.
When Console Redirection is set to
Disabled, this option will be grayed
out and unavailable.
In most modern Server Management
applications, serial data transfer is
consolidated over an alternative
faster medium like LAN, and 115.2k
is the speed of choice.
When Console Redirection is set to
Disabled, this option will be grayed
out and unavailable.
115.2K
Terminal Type
Comments
Character formatting used for console
redirection. Setting must match the remote
terminal application.
VT-UTF8
The VT100 and VT100+ terminal
emulations are essentially the same.
VT-UTF8 is a UTF8 encoding of
VT100+. PC-ANSI is the native
character encoding used by PCcompatible applications and
emulators.
When Console Redirection is set to
Disabled, this option will be grayed
out and unavailable.
Legacy OS
Redirection
Disabled
Enabled
This option enables legacy OS redirection
(that is, DOS) on serial port. If it is
enabled, the associated serial port is
hidden from the legacy OS.
Operating Systems which are
“redirection-aware” implement their
own Console Redirection
mechanisms. For a Legacy OS
which is not “aware”, this option
allows the BIOS to handle
redirection.
When Console Redirection is set to
Disabled, this option will be grayed
out and unavailable.
Terminal
Resolution
80x24
100x31
Remote Terminal Resolution.
This option allows the use of a larger
terminal screen area, although it
does not change Setup displays to
match.
When Console Redirection is set to
Disabled, this option will be grayed
out and unavailable.
Revision 1.4
125
BIOS Setup Interface
5.4.2.18
Intel® Server Board S1600JP TPS
System Information
The System Information screen allows the user to view part numbers, serial numbers, and
firmware revisions. This is an Information Only screen.
To access this screen from the Main screen, select Server Management > System
Information. To move to another screen, press the <Esc> key to return to the Server
Management screen, then select the desired screen.
Server Management
System Information
Board Part Number
<Part Number display>
Board Serial Number
<Serial Number display>
System Part Number
<Part Number display>
System Serial Number
<Serial Number display>
Chassis Part Number
<Part Number display>
Chassis Serial Number
<Serial Number display>
Asset Tag
<Asset Tag-display>
BMC Firmware Revision
<BMC FW Rev display>
ME Firmware Revision
<ME FW Rev display>
SDR Revision
<SDR Rev display>
UUID
<UUID display>
Figure 35. System Information Screen
Table 45. Setup Utility – Server Management System Information Fields
Setup Item
Options
Help Text
Comments
Board Part Number
Part Number display
None
Information only
Board Serial Number
Serial Number display
None
Information only
126
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
BIOS Setup Interface
Options
Help Text
Comments
System Part Number
Part Number display
None
Information only
System Serial Number
Serial Number display
None
Information only
Chassis Part Number
Part Number display
None
Information only
Chassis Serial Number
Serial Number display>
None
Information only
Asset Tag
Asset Tag-display
None
Information only
BMC Firmware Revision
BMC FW Rev display
None
Information only
ME Firmware Revision
ME FW Rev display
None
Information only
SDR Revision
SDR Rev display
None
Information only
UUID
UUID display
None
Information only
5.4.2.19
BMC LAN Configuration
The BMC configuration screen allows the Setup user to configure the BMC Baseboard LAN
channel and the RMM4 LAN channel, and to manage BMC User settings for up to five BMC
Users.
To access this screen from the Main screen, select Server Management > System
Information. To move to another screen, press the <Esc> key to return to the Server
Management screen, then select the desired screen.
Revision 1.4
127
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Server Management
BMC LAN Configuration
Baseboard LAN configuration
IP Source
Static/Dynamic
IP Address
[0.0.0.0]
Subnet Mask
[0.0.0.0]
Gateway IP
[0.0.0.0]
Baseboard LAN IPv6 configuration
IPv6
Disable/Enable
IPv6 source
Static/Dynamic/Auto
IPv6 address
[0000:0000:0000:0000:0000:0000:0000:0000]
Gateway IPv6
[0000:0000:0000:0000:0000:0000:0000:0000]
IPv6 Prefix Length
[0 – 128, 64 is default]
Intel(R) RMM4 IPv4 LAN configuration
Intel (R) RMM4
< Not Present/Intel(R) RMM4-Lite/Intel(R) RMM4 + DMN >
IP Source
Static/Dynamic
IP Address
[0.0.0.0]
Subnet Mask
[0.0.0.0]
Gateway IP
[0.0.0.0]
Intel(R) RMM4 IPv6 LAN configuration
IPv6 Source
Static/Dynamic/Auto
IPv6 Address
[0000:0000:0000:0000:0000:0000:0000:0000]
Gateway IPv6
[0000:0000:0000:0000:0000:0000:0000:0000]
128
Revision
1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
IPv6 Prefix Length
[0 – 128, 64 is default]
BMC DHCP Host Name
[DHCP Host Name display/edit]
User Configuration
User ID
anonymous/root/User3/User4/User5
Privilege
Callback/ User/Operator/Administrator
User status
Disable/Enable
User Name
[User Name display/edit]
User Password.
Figure 36. BMC LAN Configuration Screen
Table 46. Setup Utility – BMC configuration Screen Fields
Setup
Item
IP source
Options
Static
Dynamic
Revision 1.4
Help Text
Select BMC IP source. When Static
option is selected, IP address, subnet
mask and gateway are editable. When
Dynamic option selected, these fields
are read-only and IP is address
acquired automatically (DHCP).
Comments
This specifies the IP Source for IPv4
addressing for the Baseboard LAN.
There is a separate IP Source field for
®
the Intel RMM4 LAN configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC, and its setting determines whether
the other Baseboard LAN IPv4
addressing fields are display-only (when
Dynamic) or can be edited (when Static).
129
BIOS Setup Interface
Setup
Item
IP address
Options
Entry Field
0.0.0.0, 0.0.0.0
is default
Intel® Server Board S1600JP TPS
Help Text
Comments
View/Edit IP address. Press <Enter>
to edit.
This specifies the IPv4 Address for the
Baseboard LAN. There is a separate
IPv4 Address field for the Intel® RMM4
LAN configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IP Source
determines whether this field is displayonly (when Dynamic) or can be edited
(when Static).
When IPv6 addressing is enabled, this
field is grayed out and inactive.
Subnet
Mask
Entry Field
0.0.0.0, 0.0.0.0
is default
View/Edit subnet address. Press
<Enter> to edit.
This specifies the IPv4 addressing
Subnet Mask for the Baseboard LAN.
There is a separate IPv4 Subnet Mask
field for the Intel® RMM4 LAN
configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IP Source
determines whether this field is displayonly (when Dynamic) or can be edited
(when Static).
When IPv6 addressing is enabled, this
field is grayed out and inactive.
Gateway
IP
Entry Field
0.0.0.0, 0.0.0.0
is default
View/Edit Gateway IP address. Press
<Enter> to edit.
This specifies the IPv4 addressing
Gateway IP for the Baseboard LAN.
There is a separate IPv4 Gateway IP
field for the Intel® RMM4 LAN
configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IP Source
determines whether this field is displayonly (when Dynamic) or can be edited
(when Static).
When IPv6 addressing is enabled, this
field is grayed out and inactive.
IPv6
Enabled
Disabled
Option to Enable/Disable IPv6
addressing and any IPv6 network
traffic on these channels.
130
The initial value for this field is acquired
from the BMC. It may be changed in
order to switch between IPv4 and IPv6
addressing technologies.
Revision
1.4
Intel® Server Board S1600JP TPS
Setup
Item
Options
BIOS Setup Interface
Help Text
Comments
When this option is set to Disabled, all
other IPv6 fields will not be visible for the
Baseboard LAN and Intel® RMM4 DMN
(if installed). When IPv6 addressing is
Enabled, all IPv6 fields for the
®
Baseboard LAN and Intel RMM4 DMN
will become visible, and all IPv4 fields
will be grayed out and inactive.
IPv6
Source
Static
Dynamic
Auto
Select BMC IPv6 source: If [Static],
IPv6 parameters may be edited. If
[Dynamic], these fields are displayonly and IPv6 address is acquired
automatically (DHCP). If [Auto], these
fields are display-only and IPv6
address is acquired using ICMPv6
router / neighbor discovery.
This specifies the IP Source for IPv6
addressing for the Baseboard LAN
configuration. There is a separate IPv6
Source field for the Intel® RMM4 LAN
configuration.
This option is only visible when the IPv6
option is set to Enabled.
When IPv6 addressing is Enabled, the
initial value for this field is acquired from
the BMC, and its setting determines
whether the other Baseboard LAN IPv6
addressing fields are display-only (when
Dynamic or Auto) or can be edited
(when Static).
IPv6
Address
Entry Field
0000:0000
0000:0000
View/Edit IPv6 address. Press <Enter>
to edit. IPv6 addresses consists of
eight hexadecimal four digit numbers
separated by colons.
This specifies the IPv6 Address for the
Baseboard LAN. There is a separate
IPv6 Address field for the Intel® RMM4
LAN configuration.
This option is only visible when the IPv6
option is set to Enabled.
0000:0000
0000:0000
When IPv6 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IPv6 Source
determines whether this field is displayonly (when Dynamic or Auto) or can be
edited (when Static).
0000:0000
0000:0000
0000:0000
0000:0000
is default
Gateway
IPv6
Entry Field
0000:0000
0000:0000
0000:0000
Revision 1.4
View/Edit Gateway IPv6 address.
Press <Enter> to edit. Gateway IPv6
addresses consists of eight
hexadecimal four digit numbers
separated by colons.
This specifies the Gateway IPv6
Address for the Baseboard LAN. There
is a separate Gateway IPv6 Address
®
field for the Intel RMM4 LAN
configuration.
This option is only visible when the IPv6
option is set to Enabled.
131
BIOS Setup Interface
Setup
Item
Options
Intel® Server Board S1600JP TPS
Help Text
Comments
0000:0000
When IPv6 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IPv6 Source
determines whether this field is displayonly (when Dynamic or Auto) or can be
edited (when Static).
0000:0000
0000:0000
0000:0000
0000:0000
is default
IPv6 Prefix
Length
Entry Field 0 –
128, 64 is
default
View/Edit IPv6 Prefix Length from zero
to 128 (default 64). Press <Enter> to
edit.
This specifies the IPv6 Prefix Length for
the Baseboard LAN. There is a separate
®
IPv6 Prefix Length field for the Intel
RMM4 LAN configuration.
This option is only visible when the IPv6
option is set to Enabled.
When IPv6 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IPv6 Source
determines whether this field is displayonly (when Dynamic or Auto) or can be
edited (when Static).
®
Intel
RMM4
Not Present
None
Information only. Displays whether an
®
Intel RMM4 component is currently
installed. This information may come
from querying the BMC.
®
Intel RMM4Lite
®
®
Intel RMM4 +
DMN
Intel RMM4-Lite is the Management
Module without the Dedicated Server
Management NIC Module. When this is
present, or if the Management Module is
®
Not Present at all, the fields for Intel
RMM4 LAN Configuration will not be
visible.
®
When an Intel RMM4 + DMN is
®
installed, the options for Intel RMM4
LAN Configuration will be visible. When
IPv6 is Disabled, the IPv4 configuration
fields will be visible and the IPv6
configuration fields will not be visible.
When IPv6 is Enabled, the IPv4 fields
will be grayed out and inactive, while the
IPv6 Configuration fields will be visible.
®
In either case, the Intel RMM4 section
IP Source or IPv6 Source will determine
whether the IPv4 or IPv6 address fields
132
Revision
1.4
Intel® Server Board S1600JP TPS
Setup
Item
Options
BIOS Setup Interface
Help Text
Comments
are display-only or can be edited.
IP source
Static
Dynamic
Select RMM4 IP source: If [Static], IP
parameters may be edited. If
[Dynamic], these fields are displayonly and IP address is acquired
automatically (DHCP).
This specifies the IP Source for IPv4
®
addressing for the Intel RMM4 DMN
LAN connection. There is a separate IP
Source field for the Baseboard LAN
configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC, and its setting determines whether
®
the other Intel RMM4 DMN LAN IPv4
addressing fields are display-only (when
Dynamic) or can be edited (when Static).
When IPv6 addressing is enabled, this
field is grayed out and inactive.
IP address
Entry Field
0.0.0.0, 0.0.0.0
is default
View/Edit IP address. Press <Enter>
to edit.
This specifies the IPv4 Address for the
®
Intel RMM4 DMN LAN. There is a
separate IPv4 Address field for the
Baseboard LAN configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IP Source
determines whether this field is displayonly (when Dynamic) or can be edited
(when Static).
When IPv6 addressing is enabled, this
field is grayed out and inactive.
Subnet
Mask
Entry Field
0.0.0.0, 0.0.0.0
is default
View/Edit subnet address. Press
<Enter> to edit.
This specifies the IPv4 addressing
®
Subnet Mask for the Intel RMM4 DMN
LAN. There is a separate IPv4 Subnet
Mask field for the Baseboard LAN
configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IP Source
determines whether this field is displayonly (when Dynamic) or can be edited
(when Static).
When IPv6 addressing is enabled, this
field is grayed out and inactive.
Gateway
IP
Revision 1.4
Entry Field
0.0.0.0, 0.0.0.0
is default
View Edit Gateway IP address. Press
<Enter> to edit.
This specifies the IPv4 addressing
®
Gateway IP for the Intel RMM4 DMN
LAN. There is a separate IPv4 Gateway
IP field for the Baseboard LAN
133
BIOS Setup Interface
Setup
Item
Options
Intel® Server Board S1600JP TPS
Help Text
Comments
configuration.
When IPv4 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IP Source
determines whether this field is displayonly (when Dynamic) or can be edited
(when Static).
When IPv6 addressing is enabled, this
field is grayed out and inactive.
IPv6
Source
Static
Dynamic
Auto
®
Select Intel RMM4 IPv6 source: If
[Static], IPv6 parameters may be
edited. If [Dynamic], these fields are
display-only and IPv6 address is
acquired automatically (DHCP). If
[Auto], these fields are display-only
and IPv6 address is acquired using
ICMPv6 router / neighbor discovery.
This specifies the IP Source for IPv6
®
addressing for the Intel RMM4 DMN
LAN configuration. There is a separate
IPv6 Source field for the Baseboard LAN
configuration.
This option is only visible when the IPv6
option is set to Enabled.
When IPv6 addressing is Enabled, the
initial value for this field is acquired from
the BMC, and its setting determines
whether the other Intel® RMM4 DMN
LAN IPv6 addressing fields are displayonly (when Dynamic or Auto) or can be
edited (when Static).
IPv6
Address
Entry Field
0000:0000
0000:0000
View/Edit IPv6 address. Press <Enter>
to edit. IPv6 addresses consists of
eight hexadecimal four digit numbers
separated by colons.
This specifies the IPv6 Address for the
®
Intel RMM4 DMN LAN. There is a
separate IPv6 Address field for the
Baseboard LAN configuration.
This option is only visible when the IPv6
option is set to Enabled.
0000:0000
0000:0000
When IPv6 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IPv6 Source
determines whether this field is displayonly (when Dynamic or Auto) or can be
edited (when Static).
0000:0000
0000:0000
0000:0000
0000:0000
is default
Gateway
IPv6
Entry Field
0000:0000
0000:0000
View/Edit Gateway IPv6 address.
Press <Enter> to edit. Gateway IPv6
addresses consists of eight
hexadecimal four digit numbers
134
This specifies the Gateway IPv6
®
Address for the Intel RMM4 DMN LAN.
There is a separate Gateway IPv6
Address field for the Baseboard LAN
Revision
1.4
Intel® Server Board S1600JP TPS
Setup
Item
Options
0000:0000
BIOS Setup Interface
Help Text
separated by colons.
0000:0000
When IPv6 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IPv6 Source
determines whether this field is displayonly (when Dynamic or Auto) or can be
edited (when Static).
0000:0000
0000:0000
is default
Entry Field 0 –
128, 64 is
default
configuration.
This option is only visible when the IPv6
option is set to Enabled.
0000:0000
0000:0000
IPv6 Prefix
Length
Comments
View/Edit IPv6 Prefix Length from zero
to 128 (default 64). Press <Enter> to
edit.
This specifies the IPv6 Prefix Length for
®
the Intel RMM4 DMN LAN. There is a
separate IPv6 Prefix Length field for the
Baseboard LAN configuration.
This option is only visible when the IPv6
option is set to Enabled.
When IPv6 addressing is used, the initial
value for this field is acquired from the
BMC. The setting of IPv6 Source
determines whether this field is displayonly (when Dynamic or Auto) or can be
edited (when Static).
BMC
DHCP
Host
Name
Entry Field, 2-63 View/Edit BMC DHCP host name.
characters
Press <Enter> to edit. Host name
should start with an alphabetic,
remaining can be alphanumeric
characters. Host name length may be
from 2 to 63 characters.
This field is active and may be edited
whenever at least one of the IP Source
or IPv6 Source options is set to
Dynamic. This is the name of the DHCP
Host from which dynamically assigned
IPv4 or IPv6 addressing parameters are
acquired.
The initial value for this field is supplied
from the BMC, if there is a DHCP Host
available. The user can edit the existing
Host or enter a different DHCP Host
Name.
If none of the IP/IPv6 Source fields is set
to Dynamic, then this BMC DHCP Host
Name field will be grayed out and
inactive.
User ID
anonymous
root
User3
User4
Revision 1.4
Select the User ID to configure: User1
(anonymous), User2 (root), and
User3/4/5 are supported.
These five User IDs are fixed choices
and cannot be changed. The BMC
supports 15 User IDs natively but only
the first five are supported through this
interface.
135
BIOS Setup Interface
Setup
Item
Options
Intel® Server Board S1600JP TPS
Help Text
Comments
User5
Privilege
Callback
User
View/Select user privilege. User2
(root) privilege is "Administrator" and
cannot be changed.
The level of privilege that is assigned for
a User ID affects which functions that
user may perform.
Enable/Disable LAN access for
selected user. Also enables/disables
SOL and KVM media redirection.
Note that status setting is Disabled by
default until set to Enabled.
Operator
Administrator
Enable
User
Status
Disable
User
Name
Entry Field, 4 15 characters
Press <Enter> to edit user name. User
name is string of 4 to 15 alphanumeric
characters. User name must begin
with an alphabetic character. User
Name cannot be changed for User1
(anonymous) and User2 (root).
User Name can only be edited for users
other than “anonymous” and “root”.
Those two User Names may not be
changed.
User
Password
Popup Entry
Field, 0 - 15
characters
Press <Enter> key to enter password.
Maximum length is 15 characters. Any
ASCII printable characters can be
used: case-sensitive alphabetic,
numeric, and special characters.
This field will not indicate whether there
is a password set already. There is no
display - just press <Enter> for a popup
with an entry field to enter a new
password. Any new password entered
will override the previous password, if
there was one.
Note: Password entered will override
any previously set password.
5.4.2.20
Boot Options Screen (Tab)
The Boot Options screen displays all bootable media encountered during POST, and allows the
user to configure the desired order in which boot devices are to be tried.
The first boot device in the specified Boot Order which is present and is bootable during POST
will be used to boot the system, and will continue to be used to reboot the system until the boot
device configuration has changed (that is, which boot devices are present), or until the system
has been powered down and booted in a “cold” power-on boot.
If all types of bootable devices are installed in the system, then the default boot order is
as follows:






CD/DVD-ROM
Floppy Disk Drive
Hard Disk Drive
PXE Network Device
BEV (Boot Entry Vector) Device
EFI Shell and EFI Boot paths
To access this screen from the Main screen or other top-level “Tab” screen, press the right or
left arrow keys to traverse the tabs at the top of the Setup screen until the Boot Options screen
is selected.
136
Revision
1.4
Intel® Server Board S1600JP TPS
Main
Advanced
BIOS Setup Interface
Security
Server Management
Boot Options
System Boot Timeout
<0 – 65535, 0 is default>
Boot Option #1
<Available Boot devices>
Boot Option #2
<Available Boot devices>
Boot Option #n
<Available Boot devices>
Boot Manager
► CDROM Order
► Hard Disk Order
► Floppy Order
► Network Device Order
► BEV Device Order
► Add EFI Boot Option
► Delete EFI Boot Option
EFI Optimized Boot
Enabled/Disabled
Use Legacy Video for EFI OS
Enabled/Disabled
Boot Option Retry
Enabled/Disabled
USB Boot Priority
Enabled/Disabled
Static Boot Ordering
Enabled/Disabled
Reset Static Boot Order
Yes/No Action
Figure 37. Boot Options Screen
Revision 1.4
137
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Table 47. Setup Utility – Boot Options Screen Fields
Setup Item
System Boot
Timeout
Options
Entry Field 0 –
65535, 0 is
default
Help Text
Comments
The number of seconds BIOS will
pause at the end of POST to
allow the user to press the [F2]
key for entering the BIOS Setup
utility.
Valid values are 0-65535. Zero is
the default. A value of 65535
causes the system to go to the
Boot Manager menu and wait for
user input for every system boot.
After entering the necessary
timeout, press the <Enter> key to
register that timeout value to the
system. These settings are in
seconds. The timeout value entered
will take effect on the next boot.
This timeout value is independent of
the FRB2 setting for BIOS boot
failure protection. The FBR2
countdown will be suspended during
the time that the Boot Timeout
countdown is active.
Also, if the <Pause> key is pressed
during the time that the Boot
Timeout is active, the Boot Timeout
countdown will be suspended until
the Pause state has been dismissed
and normal POST processing has
resumed.
Boot Option #x
Available boot
devices #n.
Set system boot order by
selecting the boot option for this
position.
When the Boot order has been
chosen, it will take effect on the next
boot. The system will go down the
list and boot from the first device on
the list which is available and
bootable.
This establishes the Boot Order only
with respect to the normal boot path.
This order has no effect on the Boot
Manager selection list or the <F6>
BIOS Boot Menu popup, both of
which simply list all bootable
devices available in the order in
which they were detected. Whether
or not a potential Boot Device is in
this list has no bearing on the
presence or order of Boot Devices
shown for Boot Manager or the
BIOS Boot Menu.
CDROM Order
None
Set the order of the legacy
devices in this group.
Selection only. Select this line and
press the <Enter> key to go to the
CDROM Order Screen.
This option appears when one or
more bootable CDROM drives are
available in the system. This
includes USB CDROM devices but
138
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Options
BIOS Setup Interface
Help Text
Comments
not USB Keys formatted for
CRDOM emulation, which are seen
as Hard Disk drives.
Hard Disk Order
None
Set the order of the legacy
devices in this group.
Selection only. Select this line and
press the <Enter> key to go to the
Hard Disk Order Screen.
This option appears when one or
more bootable Hard Disk drives are
available in the system. This
includes USB Hard Disk devices
and USB Keys formatted for Hard
Disk or CRDOM emulation.
Floppy Order
None
Set the order of the legacy
devices in this group.
Selection only. Select this line and
press the <Enter> key to go to the
Floppy Order Screen.
This option appears when one or
more bootable Floppy Disk drives
are available in the system. This
includes USB Floppy Disk devices
and USB Keys formatted for Floppy
Disk emulation.
Network Device
Order
None
Set the order of the legacy
devices in this group.
Selection only. Select this line and
press the <Enter> key to go to the
Network Device Order Screen.
This option appears when one or
more bootable Network Devices are
available in the system.
BEV Device Order
None
Set the order of the legacy
devices in this group.
Selection only. Select this line and
press the <Enter> key to go to the
BEV Device Order Screen.
This option appears when one or
more bootable BEV Devices are
available in the system.
Add EFI Boot
Option
None
Add a new EFI boot option to the
boot order.
Selection only. Select this line and
press the <Enter> key to go to the
Add EFI Boot Option Screen.
This option is only displayed if an
EFI bootable device is available to
the system.
Delete Boot Option
Revision 1.4
None
Remove an EFI boot option from
the boot order.
Selection only. Select this line and
press the <Enter> key to go to the
Delete EFI Boot Option Screen.
139
BIOS Setup Interface
Setup Item
Intel® Server Board S1600JP TPS
Options
Help Text
Comments
This option is only displayed if an
EFI boot path is included in the Boot
Order.
EFI Optimized Boot
Enabled
Disabled
Use Legacy Video
for EFI OS
Enabled
Boot Option Retry
Enabled
Disabled
Disabled
USB Boot Priority
Enabled
Disabled
Static Boot Ordering
Enabled
Disabled
If enabled, the BIOS only loads
modules required for booting
EFI-aware Operating Systems.
If this option is enabled, the system
will not boot successfully to a
non-EFI-aware OS.
If enabled, the BIOS uses the
legacy video ROM instead of the
EFI video ROM.
This option appears only when EFI
Optimized Boot is enabled.
If enabled, this continually retries
non-EFI-based boot options
without waiting for user input.
This option is intended to keep
retrying for cases where the boot
devices could possibly be slow to
initially respond. For example, if the
device were “asleep” and did not
wake quickly enough. However, if
none of the devices in the Boot
Order ever responds, the BIOS will
continue to reboot indefinitely.
If enabled, newly discovered
USB devices are moved to the
top of their boot device category.
If disabled, newly discovered
USB devices are moved to the
bottom of their boot device
category.
This option enables or disables the
“USB Reorder” functionality. USB
Boot Priority, if enabled, is intended
for the case where a user wants to
be able to plug in a USB device and
immediately boot to it, for example
in case of a maintenance or System
Administration operation. If a User
Password is installed, USB Boot
Priority action is suspended when a
User Password is installed.
[Disabled] - Devices removed
from the system are deleted from
Boot Order Tables.
[Enabled] - Devices removed
have positions in Boot Order
Tables retained for later
reinsertion.
When the option changes to
“Enabled” from “Disabled”, it will
enable Static Boot Ordering (SBO)
from the next boot onward, and also
the current Boot Order will be stored
as the SBO template.
When the option changes to
“Disabled” from “Enabled”, it will
disable SBO and the SBO template
will be cleared.
Otherwise it will retain the current
Enabled/Disabled state.
Reset Static Boot
Order
Yes
No Action
[Yes] Take snapshot of current
boot order to save as Static Boot
Order Template.
140
This option will allow you to save the
Boot Order list as the Static Boot
Order template without disabling
and re-enabling the Static Boot
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Options
BIOS Setup Interface
Help Text
Comments
Order option.
Select Yes to take a snapshot of the
current Boot Options list into the
Static Boot Options list on the next
boot. After saving Static Boot
Options list, this option will change
back to No Action automatically.
This option is available only when
the Static Boot Order option is
Enabled. Otherwise it will be grayed
out and unavailable.
5.4.2.21
CDROM Order
The CDROM Order screen allows the user to control the order in which BIOS attempts to boot
from the CDROM drives installed in the system. This screen is only available when there is at
least one CDROM device available in the system configuration. Note that A USB attached
CDROM device will appear in this section. However, a USB Key formatted as a CRDOM device
will not – it will be detected as a Hard Disk device and will be included in the Hard Disk Order
Screen.
To access this screen from the Main screen, select Boot Options > CDROM Order. To move
to another screen, press the <Esc> key to return to the Boot Options screen, then select the
desired screen.
Boot Options
CDROM Order
CDROM #1
<Available CDROM devices>
CDROM #2
<Available CDROM devices>
Figure 38. CDROM Order Screen
Revision 1.4
141
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Table 48. Setup Utility – CDROM Order Fields
Setup
Item
Options
Help Text
Comments
CDROM #1
Available CDROM
devices.
Set system boot order by selecting the
boot option for this position.
Choose the order of booting
among CDROM devices by
choosing which available CDROM
device should be in each position
in the order.
CDROM #2
Available CDROM
devices.
Set system boot order by selecting the
boot option for this position.
Choose the order of booting
among CDROM devices by
choosing which available CDROM
device should be in each position
in the order.
5.4.2.22
Hard Disk Order
The Hard Disk Order screen allows the user to control the order in which BIOS attempts to boot
from the hard disk drives installed in the system. This screen is only available when there is at
least one hard disk device available in the system configuration. Note that a USB attached Hard
Disk drive or a USB Key device formatted as a hard disk will appear in this section.
To access this screen from the Main screen, select Boot Options > Hard Disk Order. To move
to another screen, press the <Esc> key to return to the Boot Options screen, then select the
desired screen.
Boot Options
Hard Disk Order
Hard Disk #1
<Available Hard Disk devices>
Hard Disk #2
<Available Hard Disk devices>
Figure 39. Hard Disk Order Screen
142
Revision
1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 49. Setup Utility – Hard Disk Order Fields
Setup
Item
Options
Help Text
Comments
Hard Disk
#1
Available Hard Disk
devices.
Set system boot order by selecting
the boot option for this position.
Choose the order of booting among
Hard Disk devices by choosing which
available Hard Disk device should be in
each position in the order.
Hard Disk
#2
Available Hard Disk
devices.
Set system boot order by selecting
the boot option for this position.
Choose the order of booting among
Hard Disk devices by choosing which
available Hard Disk device should be in
each position in the order.
5.4.2.23
Floppy Order
The Floppy Order screen allows the user to control the order in which BIOS attempts to boot
from the Floppy Disk drives installed in the system. This screen is only available when there is
at least one Floppy Disk (diskette) device available in the system configuration. Note that a USB
attached diskette drive or a USB Key device formatted as a diskette drive will appear in this
section.
To access this screen from the Main screen, select Boot Options > Floppy Order. To move to
another screen, press the <Esc> key to return to the Boot Options screen, then select the
desired screen.
Boot Options
Floppy Order
Floppy Disk #1
<Available Floppy Disk devices>
Floppy Disk #2
<Available Floppy Disk devices>
Figure 40. Floppy Order Screen
Revision 1.4
143
BIOS Setup Interface
Intel® Server Board S1600JP TPS
Table 50. Setup Utility – Floppy Order Fields
Setup
Item
Options
Help Text
Comments
Floppy Disk
#1
Available Floppy devices.
Set system boot order by selecting
the boot option for this position.
Choose the order of booting among
Floppy Disk devices by choosing
which available Floppy Disk device
should be in each position in the
order.
Floppy Disk
#2
Available Floppy devices.
Set system boot order by selecting
the boot option for this position.
Choose the order of booting among
Floppy Disk devices by choosing
which available Floppy Disk device
should be in each position in the
order.
5.4.2.24
Network Device Order
The Network Device Order screen allows the user to control the order in which BIOS attempts to
boot from the network bootable devices installed in the system. This screen is only available
when there is at least one network bootable device available in the system configuration.
To access this screen from the Main screen, select Boot Options > Network Device Order. To
move to another screen, press the <Esc> key to return to the Boot Options screen, then select
the desired screen.
Boot Options
Network Device Order
Network Device #1
<Available bootable Network devices>
Network Device #2
<Available bootable Network devices>
Figure 41. Network Device Order Screen
144
Revision
1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 51. Setup Utility – Network Device Order Fields
Setup Item
Options
Help Text
Comments
Network
Device #1
Available Network
Devices.
Set system boot order by selecting
the boot option for this position.
Choose the order of booting among
Network Devices by choosing
which available Network Device
should be in each position in the
order.
Network
Device #2
Available Network
Devices.
Set system boot order by selecting
the boot option for this position.
Choose the order of booting among
Network Devices by choosing
which available Network Device
should be in each position in the
order.
5.4.2.25
BEV Device Order
The BEV Device Order screen allows the user to control the order in which BIOS attempts to
boot from the BEV Devices installed in the system. This screen is only available when there is at
least one BEV device available in the system configuration.
To access this screen from the Main screen, select Boot Options > BEV Device Order. To
move to another screen, press the <Esc> key to return to the Boot Options screen, then select
the desired screen.
Boot Options
BEV Device Order
BEV Device #1
<Available BEV devices>
BEV Device #2
<Available BEV devices>
Figure 42. BEV Device Order Screen
Table 52. Setup Utility – BEV Device Order Fields
Setup Item
BEV Device
#1
Revision 1.4
Options
Available BEV
Devices.
Help Text
Set system boot order by
selecting the boot option for this
position.
Comments
Choose the order of booting among BEV
Devices by choosing which available
BEV Device should be in each position in
the order.
145
BIOS Setup Interface
Setup Item
BEV Device
#2
Intel® Server Board S1600JP TPS
Options
Help Text
Available BEV
Devices.
5.4.2.26
Comments
Set system boot order by
selecting the boot option for this
position.
Choose the order of booting among BEV
Devices by choosing which available
BEV Device should be in each position in
the order.
Add EFI Boot Option
The Add EFI Boot Option screen allows the user to add an EFI boot option to the boot order.
This screen is only available when there is at least one EFI bootable device present in the
system configuration. The “Internal EFI Shell” Boot Option is permanent and cannot be added or
deleted.
To access this screen from the Main screen, select Boot Options > Add EFI Boot Option. To
move to another screen, press the <Esc> key to return to the Boot Options screen, then select
the desired screen.
Boot Options
Add EFI Boot Option
Add boot option label
[Enter label]
Select File system
<Available Filesystems>
Path for boot option
[Enter boot path]
Save
Figure 43. Add EFI Boot Option Screen
Table 53. Setup Utility – Add Boot Option Fields
Setup Item
Options
Add boot option
label
Enter Label
Create the label for the new boot
option.
Help Text
This label becomes an
abbreviation for this Boot Path.
Select File system
Available Filesystems
Select one filesystem from this list.
Choose the filesystem on which
this boot path resides.
146
Comments
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
BIOS Setup Interface
Options
Help Text
Comments
Path for boot option
Enter boot path
Enter the path to the boot option in
the format \path\filename.efi.
This will be the Boot Path,
residing on the filesystem
chosen, which will be entered
into the Boot Order with the Label
entered above.
Save
None
Save the boot option.
Selection only. This will save the
new Boot Option into the Boot
Order.
5.4.2.27
Delete EFI Boot Option
The Delete EFI Boot Option screen allows the user to remove an EFI boot option from the boot
order. The “Internal EFI Shell” Boot Option will not be listed, since it is permanent and cannot be
added or deleted.
To access this screen from the Main screen, select Boot Options > Delete EFI Boot Option. To
move to another screen, press the <Esc> key to return to the Boot Options screen, then select
the desired screen.
Boot Options
Delete EFI Boot Option
Delete Boot Option
<Available EFI Boot Options>
Figure 44. Delete EFI Boot Option Screen
Table 54. Setup Utility – Delete EFI Boot Option Fields
Setup Item
Delete Boot Option
5.4.2.28
Options
Available EFI Boot
Options
Help Text
Select one to delete.
Comments
This will not allow a user to delete
the EFI Shell.
Boot Manager Screen (Tab)
The Boot Manager screen allows the user to view a list of devices available for booting, and to
select a boot device for immediately booting the system. There is no predetermined order for
listing bootable devices. They are simply listed in order of discovery. Regardless of whether any
other bootable devices are available, the “Internal EFI Shell” will always be available.
To access this screen from the Main screen or other top-level “Tab” screen, press the right or
left arrow keys to traverse the tabs at the top of the Setup screen until the Boot Manager screen
is selected.
Revision 1.4
147
BIOS Setup Interface
Main
Intel® Server Board S1600JP TPS
Advanced
Security
Server Management
Boot Options
Boot Manager
Internal EFI Shell
<Boot Device #1>
<Boot Device #2>
<Boot Device #n>
Figure 45. Boot Manager Screen
Table 55. Setup Utility – Boot Manager Screen Fields
Setup Item
Options
Internal EFI
Shell
None
Boot Device #n
None
Help Text
Comments
Select this option to boot now.
Note: This list is not the system boot option
order. Use the Boot Options menu to view
and configure the system boot option order.
Select this option to boot now.
Note: This list is not the system boot option
order. Use the Boot Options menu to view
and configure the system boot option order.
The EFI Shell will always be
present in the list of bootable
devices.
These are names of bootable
devices discovered in the system.
The system user can choose any
of them from which to initiate a
one-time boot – that is, booting
from any device in this list will not
permanently affect the defined
system Boot Order.
These bootable devices are not
displayed in any specified order,
particularly not in the system Boot
Order established by the Boot
Options screen. This is just a list
of bootable devices in the order in
which they were enumerated.
5.4.2.29
Error Manager Screen (Tab)
The Error Manager screen displays any POST Error Codes encountered during BIOS POST,
along with an explanation of the meaning of the Error Code in the form of a Help Text. This is an
Information Only screen.
148
Revision
1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
To access this screen from the Main screen or other top-level “Tab” screen, press the right or
left arrow keys to traverse the tabs at the top of the Setup screen until the Error Manager screen
is selected.
Error Manager
Save&Exit
ERROR CODE
SEVERITY
INSTANCE
Description
<Post Code>
<Major/Minor>
<Instance #>>
<Description>
5224
Major
N/A
This is an example.
Figure 46. Error Manager Screen
Table 56. Setup Utility – Error Manager Screen Fields
Setup Item
Options
Help Text
Comments
ERROR CODE
Post
Code
None
This is a POST Error Code – a BIOS-originated
error that occurred during POST initialization.
SEVERITY
Minor
None
Each POST Error Code has a Severity associated
with it.
Major
Fatal
INSTANCE
Depend
on Error
Code
None
Where applicable, this field shows a value
indicating which one of a group of components
was responsible for generating the POST Error
Code that is being reported.
Description
None
Description of
POST Error Code
This is a description of the meaning of the POST
Error Code that is being reported. This text
actually appears in the screen space that is
usually reserved for “Help” messages.
5.4.2.30
Save and Exit Screen (Tab)
The Save and Exit screen allows the user to choose whether to save or discard the
configuration changes made on other Setup screens. It also allows the user to restore the BIOS
settings to the factory defaults or to save or restore them to a set of user-defined default values.
If Load Default Values is selected, the factory default settings (noted in bold in the Setup screen
images) are applied. If Load User Default Values is selected, the system is restored to
previously saved User Default Values.
Revision 1.4
149
BIOS Setup Interface
Intel® Server Board S1600JP TPS
To access this screen from the Main screen or other top-level Tab screen, press the right or left
arrow keys to traverse the tabs at the top of the Setup screen until the Exit screen is selected.
Note that there is a Legal Disclaimer footnote at the bottom of the Save & Exit screen:
*Certain brands and names may be claimed as the property of others.
This is reference to any instance in the Setup screens where names belonging to other
companies may appear. For example, “LSI*” appears in Setup in the context of Mass Storage
RAID options.
Error Manager
Save & Exit
Save Changes and Exit
Discard Changes and Exit
Save Changes
Discard Changes
Load Default Values
Save as User Default Values
Load User Default Values
*Certain brands and names may be claimed as the property of others.
Figure 47. Save & Exit Screen
150
Revision
1.4
Intel® Server Board S1600JP TPS
BIOS Setup Interface
Table 57. Setup Utility – Exit Screen Fields
Setup Item
Save Changes
and Exit
Options
None
Help Text
Exit the BIOS Setup
utility after saving
changes. The system
reboots if required.
The [F10] key can also
be used.
Comments
Selection only. Select this line and press the
<Enter> key to exit Setup with any changes in
BIOS settings saved. If there have been no
changes made in the settings, the BIOS will
resume executing POST.
If changes have been made in BIOS settings, a
confirmation pop-up will appear. If the “Save
Changes & Exit” action is positively confirmed,
any persistent changes will applied and saved to
the BIOS settings in NVRAM storage, then the
system will reboot if necessary (which is
normally the case). If the “Save Changes & Exit”
action is not confirmed, BIOS will resume
executing Setup.
The <F10> function key may also be used from
anyplace in Setup to initiate a “Save Changes &
Exit” action.
Discard Changes
and Exit
None
Exit the BIOS Setup
utility without saving
changes.
The [Esc] key can also
be used.
Selection only. Select this line and press the
<Enter> key to exit Setup without saving any
changes in BIOS settings. If there have been no
changes made in the settings, the BIOS will
resume executing POST.
If changes have been made in BIOS settings, a
confirmation pop-up will appear. If the “Discard
Changes & Exit” action is positively confirmed,
all pending changes will be discarded and BIOS
will resume executing POST. If the “Discard
Changes & Exit” action is not confirmed, BIOS
will resume executing Setup without discarding
any changes.
The <Esc> key may also be used in Setup to
initiate a “Discard Changes & Exit” action.
Save Changes
None
Save Changes made so
far to any of the setup
options.
Selection only. Select this line and press the
<Enter> key to save any pending changes in
BIOS settings.
Also, the user should be aware that most
changes require a reboot to become active. If
changes have been made and saved, without
exiting Setup, the system should be rebooted
later even if no additional changes are made.
Revision 1.4
151
BIOS Setup Interface
Setup Item
Discard Changes
Intel® Server Board S1600JP TPS
Options
None
Help Text
Comments
Discard Changes made
Selection only. Select this line and press the
so far to any of the setup <Enter> key to discard any pending unsaved
options.
changes in BIOS settings. If there have been no
changes made in the settings, the BIOS will
resume executing POST.
If changes have been made in BIOS settings
and not yet saved, a confirmation pop-up will
appear. If the “Discard Changes” action is
positively confirmed, all pending changes will be
discarded and BIOS will resume executing
POST. If the “Discard Changes” action is not
confirmed, BIOS will resume executing Setup
without discarding pending changes.
Load Default
Values
None
Load Defaults Values for
all the setup options.
Selection only. Select this line and press the
<Enter> key to load default values for all BIOS
settings. These are the initial factory settings
(“failsafe” settings) for all BIOS parameters.
There will be a confirmation popup to verify that
the user really meant to take this action.
After initializing all BIOS settings to default
values, the BIOS will resume executing Setup,
so the user may make additional changes in the
BIOS settings if necessary (for example, Boot
Order) before doing a “Save Changes and Exit”
with a reboot to make the default settings take
effect, including any changes made after loading
the defaults.
The <F9> function key may also be used from
any place in Setup to initiate a “Load Default
Values” action.
152
Revision
1.4
Intel® Server Board S1600JP TPS
Setup Item
Save as User
Default Values
BIOS Setup Interface
Options
None
Help Text
Save the changes made
so far as User Default
Values.
Comments
Selection only. Select this line and press the
<Enter> key to save the current state of the
settings for all BIOS parameters as a
customized set of “User Default Values”.
These are a user-determined set of BIOS
default settings that can be used as an
alternative instead of the initial factory settings
(“failsafe” settings) for all BIOS parameters.
By changing the BIOS settings to values that the
user prefers to have for defaults, and then using
this operation to save them as “User Default
Values”, that version of BIOS settings can be
restored at any time by using the following “Load
User Default Values” operation.
There will be a confirmation popup to verify that
the user really intended to take this action.
Loading the “factory default” values with F9 or
the “Load Default Values” – or by any other
means – does not affect the User Default
Values. They remain set to whatever values
they were saved as.
Load User Default
Values
None
Load user default values
to all the set options.
Selection only. Select this line and press the
<Enter> key to load User Default Values for all
BIOS settings. These are user-customized BIOS
default settings for all BIOS parameters,
previously established by doing a “Save User
Defaults” action (see above).
There will be a confirmation popup to verify that
the user really intended to take this action.
5.5
Loading BIOS Defaults
Different mechanisms exist for resetting the system configuration to the default values. When a
request to reset the system configuration is detected, the BIOS loads the default system
configuration values during the next POST.
You can send the request to reset the system to the defaults in the following ways:

Pressing <F9> from within the BIOS Setup utility

Moving the clear system configuration jumper

IPMI command (set System Boot options command)

Int15 AX=DA209

Choosing Load User Defaults from the Exit page of the BIOS Setup loads user set
defaults instead of the BIOS factory defaults
Revision 1.4
153
BIOS Setup Interface
Intel® Server Board S1600JP TPS
The recommended steps to load the BIOS defaults are:
1. Power down the system (Do not remove AC power)
2. Move the BIOS DFLT jumper from pins 1-2 to pins 2-3
3. Move the BIOS DFLT jumper from pins 2-3 to pins 1-2
4. Power up the system
.
154
Revision
1.4
Intel® Server Board S1600JP TPS
6.
Configuration Jumpers
Configuration Jumpers
The following table provides a summary and description of configuration, test, and debug
jumpers on the Intel® Server Board S1600JP. The server board has several 3-pin jumper blocks
that can be used.
Pin 1 on each jumper block can be identified by the following symbol on the silkscreen:
Figure 48. Jumper Blocks (J2B1, J2B3, J2B5, J2B6, J2B4, and J2B2)
Table 58. Server Board Jumpers (J6B1, J1E2, J1E3, J1E1, J1D5)
Jumper Name
J2B1: ME Force Update
J2B4: BMC Force
Update jumper
Revision 1.4
Jumper Position
Mode of
Operation
Note
1-2
Normal
Normal mode.
2-3
Update
ME in force update mode.
1-2
Normal
Normal mode.
2-3
Update
BMC in force update mode.
155
Configuration Jumpers
Intel® Server Board S1600JP TPS
Jumper Name
Mode of
Operation
Jumper Position
J2B6: Password Clear
1-2
2-3
Clear Password
BIOS password is cleared.
J2B3: BIOS Recovery
Mode
1-2
Normal
Normal mode.
2-3
Recovery
BIOS in recovery mode.
J2B2: CPLD Update
1-2
Normal
Normal mode.
2-3
Update
J2B5: BIOS Default
1-2
Normal
Normal mode.
2-3
Clear BIOS
Settings
BIOS settings are reset to factory default.
6.1.1
Normal
Note
Normal mode, password in protection.
Force Integrated BMC Update (J2B4)
When performing a standard BMC firmware update procedure, the update utility places the
BMC into an update mode, allowing the firmware to load safely onto the flash device. In the
unlikely event the BMC firmware update process fails due to the BMC not being in the proper
update state, the server board provides a BMC Force Update jumper (J6B1) which will force the
BMC into the proper update state. The following procedure should be followed in the event the
standard BMC firmware update process fails.
Table 59. Force Integrated BMC Update Jumper
Jumper Position
Mode of
Operation
Note
1-2
Normal
Normal operation.
2-3
Update
BMC in force update mode.
Steps to perform Force BMC Update:
1. Power down and remove the AC power cord.
2. Open the server chassis. See your Server Chassis Documentation for instructions.
3. Move jumper from the default operating position, covering pins1 and 2, to the enabled
position, covering pins 2 and 3.
4. Close the server chassis.
5. Reconnect the AC cord and power up the server.
6. Perform the BMC firmware update procedure as documented in the ReleaseNote.TXT
file included in the given BMC firmware update package. After successful completion of
the firmware update process, the firmware update utility may generate an error stating
the BMC is still in update mode.
7. Power down and remove the AC power cord.
8. Open the server chassis.
9. Move the jumper from the enabled position, covering pins 2 and 3 to the disabled
position, covering pins 1 and 2.
10. Close the server chassis.
11. Reconnect the AC cord and power up the server.
156
Revision
1.4
Intel® Server Board S1600JP TPS
Configuration Jumpers
Note: Normal BMC functionality is disabled with the Force BMC Update jumper is set to the
enabled position. You should never run the server with the BMC Force Update jumper set in this
position. You should only use this jumper setting when the standard firmware update process
fails. This jumper should remain in the default/disabled position when the server is running
normally.
The server board has several 3-pin jumper blocks that can be used to configure, protect, or
recover specific features of the server board.
6.1.2
Force ME Update (J2B1)
When this 3-pin jumper is set, it manually puts the ME firmware in update mode, which enables
the user to update ME firmware code when necessary.
Table 60. Force ME Update Jumper
Jumper Position
Mode of
Operation
Note
1-2
Normal
Normal operation
2-3
Update
ME in force update mode
Note: Normal ME functionality is disabled with the Force ME Update jumper is set to the
enabled position. Never run the server with the ME Force Update jumper set in this position.
Only use this jumper setting when the standard firmware update process fails. This jumper
should remain in the default/disabled position when the server is running normally.
Steps to perform the Force ME Update:
1.
Power down and remove the AC power cord.
2.
Open the server chassis. For instructions, see your Server Chassis Documentation.
3.
Move jumper from the default operating position (covering pins 1 and 2) to the enabled
position (covering pins 2 and 3).
4.
Close the server chassis.
5.
Reconnect the AC cord and power up the server.
6.
Perform the ME firmware update procedure as documented in the README.TXT file
that is included in the given ME firmware update package (same package as BIOS).
7.
Power down and remove the AC power cord.
8.
Open the server chassis.
9.
Move jumper from the enabled position (covering pins 2 and 3) to the disabled position
(covering pins 1 and 2).
10. Close the server chassis.
6.1.3
Password Clear (J2B6)
The user sets this 3-pin jumper to clear the password.
Revision 1.4
157
Configuration Jumpers
Intel® Server Board S1600JP TPS
Table 61. Password Clear Jumper
Jumper
Position
Mode of
Operation
Note
1-2
Normal
Normal mode, password in protection.
2-3
Clear Password
BIOS password is cleared.
Steps to clear the BIOS password:
1. Power down server. Do not unplug the power cord.
2. Open the chassis. For instructions, see your Server Chassis Documentation.
3. Move jumper (J1B6) from the default operating position, covering pins 1 and 2, to the
password clear position, covering pins 2 and 3.
4. Close the server chassis.
5. Power up the server, wait 10 seconds or until POST completes.
6. Power down the server.
7. Open the chassis and move the jumper back to default position, covering pins 1 and 2.
8. Close the server chassis.
9. Power up the server.
The password is now cleared and you can reset it by going into the BIOS setup.
6.1.4
BIOS Recovery Mode (J2B3)
®
The Intel Server Board S1600JP uses BIOS recovery to repair the system BIOS from flash
corruption in the main BIOS and Boot Block. This 3-pin jumper is used to reload the BIOS when
the image is suspected to be corrupted. For directions on how to recover the BIOS, refer to the
specific BIOS release notes.
Table 62. BIOS Recovery Mode Jumper
Jumper
Position
Mode of Operation
Note
1-2
Normal
Normal mode.
2-3
Recovery
BIOS in recovery mode.
You can accomplish a BIOS recovery from the SATA CD and USB Mass Storage device.
Please note that this platform does not support recovery from a USB floppy.
The recovery media must contain the following files under the root directory:
1.
2.
3.
4.
RML.ROM
UEFI iFlash32 11.0 Build 2 (including iFlash32.efi and ipmi.efi)
*Rec.CAP
Startup.nsh (update accordingly to use proper *Rec.CAP file)
158
Revision
1.4
Intel® Server Board S1600JP TPS
Configuration Jumpers
The BIOS starts the recovery process by first loading and booting to the recovery image file
(RML.ROM) on the root directory of the recovery media (USB disk). This process takes place
before any video or console is available. Once the system boots to this recovery image file
(FVMAIN.FV), it boots automatically into the EFI Shell to invoke the Startup.nsh script and start
the flash update application (IFlash32.efi). IFlash32.efi requires the supporting BIOS Capsule
image file (*Rec.CAP).
After the update is complete, a message displays, stating the BIOS has been updated
successfully. This indicates the recovery process is finished.
The user should then switch the recovery jumper back to normal operation and restart the
system by performing a power cycle.
The following steps demonstrate this recovery process:
1. Power OFF the system.
2. Insert recovery media.
3. Switch the recovery jumper. Details regarding the jumper ID and location can be obtained
from the Board EPS for that Platform.
4. Power ON the system.
5. The BIOS POST screen will appear displaying the progress, and the system automatically
boots to the EFI SHELL.
6. The Startup.nsh file executes, and initiates the flash update (IFlash32.efi) with a new
capsule file (*Rec.CAP). The regular iFlash message displays at the end of the process—
once the flash update succeeds.
7. Power OFF the system, and revert the recovery jumper position to "normal operation".
8. Power ON the system.
9. Do NOT interrupt the BIOS POST during the first boot.
6.1.5
Reset BIOS Settings (J2B5)
The former name for this jumper is CMOS Clear. It is used to be the BIOS reset jumper. Since
the previous generation, the BIOS has moved CMOS data to the NVRAM region of the BIOS
flash. The BIOS checks during boot to determine if the data in the NVRAM needs to be set to
default. (Same function as F9 in BIOS that loads BIOS by default.)
Table 63. Reset BIOS Jumper
Jumper Position
Mode of Operation
Note
1-2
Normal
Normal mode.
2-3
Clear BIOS settings
BIOS settings are reset to factory default.
Steps to clear BIOS settings:
1. Power down server. Do not unplug the power cord.
2. Open the server chassis. For instructions, see your Server Chassis Documentation.
3. Move jumper (J1D5) from the default operating position, covering pins 1 and 2, to the
reset/clear position, covering pins 2 and 3.
Revision 1.4
159
Configuration Jumpers
4.
5.
6.
7.
8.
Intel® Server Board S1600JP TPS
Wait five seconds.
Remove AC power.
Move the jumper back to default position, covering pins 1 and 2.
Close the server chassis.
Power up the server.
The BIOS settings are now cleared and you can reset it by going into the BIOS setup.
Note: Removing AC Power before performing the BIOS settings Clear operation causes the
system to automatically power up and immediately power down, after the procedure is followed
and AC power is re-applied. If this happens, remove the AC power cord again, wait 30 seconds,
and re-install the AC power cord. Power-up the system and proceed to the <F2> BIOS Setup
Utility to reset the desired settings.
160
Revision
1.4
Intel® Server Board S1600JP TPS
Connector/Header Locations and Pin-out
7.
Connector/Header Locations and Pin-out
7.1
Power Connectors
To facilitate customers who want to cable to this board from a power supply, the power
connectors are implemented through one 10-pin connector and one 8-pin connector.
Table 64. Main Power Supply Connector 10-pin 2x5 Connector Pin-Out (J4K1)
Pin
1
2
3
4
5
Signal Name
PSON
GND
GND
GND
5V
Pin
Signal Name
6
7
8
9
10
5VSB
PWROK
3.3V
3.3V
Reserved
Table 65. Main Power Supply Connector 8-pin 2x4 Connector Pin-Out (J6K1)
Pin
1
2
3
4
7.2
7.2.1
Signal Name
GND
GND
GND
GND
Pin
Signal Name
5
6
7
8
+12V
+12V
+12V
+12V
System Management Headers
Intel® Remote Management Module 4 (Intel® RMM4 Lite) Connector
A 7-pin Intel® RMM4 Lite connector (J6A2) is included on the server board to support the
optional Intel® Remote Management Module 4. There is no support for third-party management
cards on this server board.
Note: This connector is not compatible with the Intel® Remote Management Module 3
(Intel® RMM3).
Table 66. Intel® RMM4 Lite Connector Pin-out (J6A2)
Pin
1
3
5
7
Revision 1.4
Signal Description
P3V3_AUX
Key Pin
SPI_BMC_BK_DO
SPI_BMC_BK_CS_N
Pin
2
4
6
8
Signal Description
SPI_BMC_BK_DI
SPI_BMC_BK_CLK
GND
GND
161
Connector/Header Locations and Pin-out
7.2.2
Intel® Server Board S1600JP TPS
IPMB Header
Table 67. IPMB Header Pin-Out (J6A4)
Pin
1
2
3
4
7.2.3
Signal Name
SMB_IPMB_5VSB_DAT
GND
SMB_IPMB_5VSB_CLK
P5V_STBY
Power Button
The BIOS supports a front control panel power button. Pressing the power button initiates a
request that the Integrated BMC forwards to the ACPI power state machines in the chipset. It is
monitored by the Integrated BMC and does not directly control power on the power supply.

Power Button — Off to On
The Integrated BMC monitors the power button and the wake-up event signals from the
chipset. A transition from either source results in the Integrated BMC starting the powerup sequence. Since the processor is not executing, the BIOS does not participate in this
sequence. The hardware receives the power good and reset signals from the Integrated
BMC and then transitions to an ON state.

Power Button — On to Off (operating system absent)
The System Control Interrupt (SCI) is masked. The BIOS sets up the power button event
to generate an SMI and checks the power button status bit in the ACPI hardware
registers when an SMI occurs. If the status bit is set, the BIOS sets the ACPI power state
of the machine in the chipset to the OFF state. The Integrated BMC monitors power
state signals from the chipset and de-asserts PS_PWR_ON to the power supply. As a
safety mechanism, if the BIOS fails to service the request, the Integrated BMC
automatically powers off the system in four to five seconds.

Power Button — On to Off (operating system present)
If an ACPI operating system is running, pressing the power button switch generates a
request through SCI to the operating system to shutdown the system. The operating
system retains control of the system and the operating system policy determines the
sleep state into which the system transitions, if any. Otherwise, the BIOS turns off
the system.
7.2.4
Reset Button
The platform supports a front control panel reset button. Pressing the reset button initiates a
request forwarded by the Integrated BMC to the chipset. The BIOS does not affect the behavior
of the reset button.
7.2.5
Chassis Identify Button
The front panel Chassis Identify button toggles the state of the chassis ID LED. If the LED is off,
pushing the ID button lights the LED. It remains lit until the button is pushed again or until a
Chassis Identify or a Chassis Identify LED command is received to change the state of
the LED.
162
Revision
1.4
Intel® Server Board S1600JP TPS
7.2.6
Connector/Header Locations and Pin-out
Power LED
The green power LED is active when the system DC power is on. The power LED is controlled
by the BIOS. The power LED reflects a combination of the state of system (DC) power and the
system ACPI state. The following table identifies the different states that the power LED
can assume.
Table 68. Power LED Indicator States
State
Power off
Power on
S5
S1 Sleep
S0
7.2.7
ACPI
No
No
Yes
Yes
Yes
Power LED
Off
Solid on
Off
~1 Hz blink
Solid on
System Status LED
Note: The system status LED state shows the state for the current, most severe fault. For
example, if there was a critical fault due to one source and a non-critical fault due to another
source, the system status LED state would be solid on (the critical fault state).
The system status LED is a bicolor LED. Green (status) shows a normal operation state or a
degraded operation. Amber (fault) shows the system hardware state and overrides the
green status.
The Integrated BMC-detected state and the state from the other controllers, such as the
SCSI/SATA hot-swap controller state, are included in the LED state. For fault states monitored
by the Integrated BMC sensors, the contribution to the LED state follows the associated sensor
state, with the priority going to the most critical state currently asserted.
When the server is powered down (transitions to the DC-off state or S5), the Integrated BMC is
still on standby power and retains the sensor and front panel status LED state established prior
to the power-down event.
The following table maps the system state to the LED state:
Figure 49. System Status LED (A), 5V StandBy LED (B), and ID LED (C)
Revision 1.4
163
Connector/Header Locations and Pin-out
Intel® Server Board S1600JP TPS
Table 69. System Status LED
Color
State
System Status
Green
Green
Solid on
~1 Hz blink
Ok
Degraded
Amber
~1 Hz blink
Non-Fatal
Amber
Solid on
Fatal
Off
N/A
Not ready
Description
System ready
BIOS detected

Unable to use all of the installed memory (more than one
1
DIMM installed).

In a mirrored configuration, when memory mirroring takes
place and system loses memory redundancy. This is not
1
covered by (2).

PCI Express* correctable link errors.
Integrated BMC detected

Redundancy loss such as a power supply or fan. Applies
only if the associated platform subsystem has redundancy
capabilities.

CPU disabled – if there are two CPUs and one CPU is
disabled.

Fan alarm – Fan failure. Number of operational fans should
be more than minimum number needed to cool the system.

Non-critical threshold crossed – Temperature, voltage,
power nozzle, power gauge, and PROCHOT2 (Therm Ctrl)
sensors.

Battery failure.

Predictive failure when the system has redundant power
supplies.
Non-fatal alarm – system is likely to fail:
BIOS Detected

In non-mirroring mode, if the threshold of ten correctable
1
errors is crossed within the window.

PCI Express* uncorrectable link errors.
Integrated BMC Detected

Critical threshold crossed – Voltage, temperature, power
nozzle, power gauge, and PROCHOT (therm Ctrl) sensors.

VRD Hot asserted.

Minimum number of fans to cool the system are not present
or have failed.
Fatal alarm – system has failed or shutdown:
BIOS Detected

DIMM failure when there is one DIMM present and no good
1
memory is present.

Run-time memory uncorrectable error in non-redundant
1
mode.

CPU configuration error (for instance, processor stepping
mismatch).
Integrated BMC Detected

CPU CATERR signal asserted.

CPU 1 is missing.

CPU THERMTRIP.

No power good – power fault.

Power Unit Redundancy sensor – Insufficient resources
offset (indicates not enough power supplies are present).
Main power off
Notes:
1.
2.
The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to
provide the contribution to the system status LED.
Support for an upper, non-critical threshold limit is not provided in default SDR configuration. However if a
user does enable this threshold in the SDR, then the system status LED should behave as described.
164
Revision
1.4
Intel® Server Board S1600JP TPS
7.2.8
Connector/Header Locations and Pin-out
Chassis ID LED
The chassis ID LED provides a visual indication of a system being serviced. The state of the
chassis ID LED is affected by the following:

Toggled by the chassis ID button

Controlled by the Chassis Identify command (IPMI)

Controlled by the Chassis Identify LED command (OEM)
Table 70. Chassis ID LED Indicator States
State
LED State
Identify active through button
Identify active through command
Off
Solid on
~1 Hz blink
Off
There is no precedence or lock-out mechanism for the control sources. When a new request
arrives, all previous requests are terminated. For example, if the chassis ID LED is blinking and
the chassis ID button is pressed, then the chassis ID LED changes to solid on. If the button is
pressed again with no intervening commands, the chassis ID LED turns off.
7.3
I/O Connectors
7.3.1
PCI Express* Connectors
®
The Intel Server Board S1600JP uses three PCI Express* slots physically with different pint out
definition. Each riser slot has dedicated usage and cannot be used for normal PCIe based addin card.

Riser Slot 1: Riser to support PCIe x16 add-in card

Riser Slot 2: Riser to support PCIe x8 Intel® IOM card

Riser Slot 3: Riser to support PCIe x16 add-in card or double width PCI Express* card
The pin-outs for the slots are shown in the following tables.
Table 71. PCI Express* x16 Riser Slot 1 Connector (J6B1)
Pin
Pin Name
B1
12V
B2
12V
B3
12V
B4
B5
GND
SMBUS_R4
CLK
SMBUS_R4
DAT
GND
3.3V
B6
B7
B8
Revision 1.4
Description
66W for double width
PCI Express*card
66W for double width
PCI Express*card
66W for double width
PCI Express*card
Pin
Pin Name
A1
Present1
A2
12V
A3
12V
A4
A5
GND
Description
66W for double width PCI
Express*card
66W for double width PCI
Express*card
3.3V
For wake on LAN
A6
A7
A8
spare
spare
3.3V
165
Connector/Header Locations and Pin-out
Pin
B9
B10
B11
Pin Name
Spare
3.3VAUX
WAKE#
Description
For wake on LAN
For wake on LAN
Intel® Server Board S1600JP TPS
Pin
Pin Name
A9
A10
A11
3.3V
3.3V
PERST#
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32
A33
A34
A35
A36
A37
A38
GND
REFCLK1+
REFCLK1GND
PERxP0
PERxN0
GND
3.3V
GND
PERxP1
PERxN1
GND
GND
PERxP2
PERxN2
GND
GND
PERxP3
PERxN3
GND
REFCLK2+
REFCLK2GND
PERxP4
PERxN4
GND
GND
A39
A40
A41
A42
A43
A44
A45
A46
A47
A48
A49
A50
A51
A52
A53
A54
A55
A56
A57
A58
PERxP5
PERxN5
GND
GND
PERxP6
PERxN6
GND
GND
PERxP7
PERxN7
GND
Riser ID 1
GND
PERxP8
PERxN8
GND
GND
PERxP9
PERxN9
GND
Description
KEY
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
B30
B31
B32
B33
B34
B35
B36
B37
B38
3.3V
GND
PETxP0
PETxN0
GND
Present2
GND
PETxP1
PETxN1
GND
GND
PETxP2
PETxN2
GND
GND
PETxP3
PETxN3
GND
3.3V
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B50
B51
B52
B53
B54
B55
B56
B57
B58
GND
GND
PETxP6
PETxN6
GND
GND
PETxP7
PETxN7
GND
Riser ID 0
GND
PETxP8
PETxN8
GND
GND
PETxP9
PETxN9
GND
GND
PETxP10
GND
PETxP4
PETxN4
GND
GND
PETxP5
PETxN5
Tx Lane 0+
Tx Lane 0+
Tx Lane 1+
Tx Lane 1‐ Tx Lane 2+
Tx Lane 2-
Tx Lane 3+
Tx Lane 3-
Tx Lane 4+
Tx Lane 4-
Tx Lane 5+
Tx Lane 5‐ Tx Lane 6+
Tx Lane 6-
Tx Lane 7+
Tx Lane 7-
Tx Lane 8+
Tx Lane 8-
Tx Lane 9+
Tx Lane 9-
Tx Lane 10+
166
Clock pair 1
Clock pair 1
Rx Lane 0+
Rx Lane 0-
Rx Lane 1+
Rx Lane 1-
Rx Lane 2+
Rx Lane 2-
Rx Lane 3+
Rx Lane 3Clock pair 2
Clock pair 2
Rx Lane 4+
Rx Lane 4-
Rx Lane 5+
Rx Lane 5-
Rx Lane 6+
Rx Lane 6-
Rx Lane 7+
Rx Lane 7-
Rx Lane 8+
Rx Lane 8-
Rx Lane 9+
Rx Lane 9-
Revision
1.4
Intel® Server Board S1600JP TPS
Pin
B59
B60
B61
B62
B63
B64
B65
B66
B67
B68
B69
B70
B71
B72
B73
B74
B75
B76
B77
B78
B79
B80
B81
B82
Connector/Header Locations and Pin-out
Pin Name
Description
PETxN10
GND
GND
PETxP11
PETxN11
GND
GND
PETxP12
PETxN12
GND
GND
PETxP13
PETxN13
GND
GND
PETxP14
PETxN14
GND
GND
PETxP15
PETxN15
GND
REFCLK3+
REFCLK3-
Tx Lane 10-
Pin
A59
A60
A61
A62
A63
A64
A65
A66
A67
A68
A69
A70
A71
A72
A73
A74
A75
A76
A77
A78
A79
A80
A81
A82
Tx Lane 11+
Tx Lane 11-
Tx Lane 12+
Tx Lane 12-
Tx Lane 13+
Tx Lane 13-
Tx Lane 14+
Tx Lane 14-
Tx Lane 15+
Tx Lane 15Clock pair 3
Clock pair 3 Pin Name
GND
PERxP10
PERxN10
GND
GND
PERxP11
PERxN11
GND
GND
PERxP12
PERxN12
GND
GND
PERxP13
PERxN13
GND
GND
PERxP14
PERxN14
GND
GND
PERxP15
PERxN15
GND
Description
Rx Lane 10+
Rx Lane 10-
Rx Lane 11+
Rx Lane 11-
Rx Lane 12+
Rx Lane 12-
Rx Lane 13+
Rx Lane 13-
Rx Lane 14+
Rx Lane 14-
Rx Lane 15+
Rx Lane 15-
Table 72. PCI Express* x8 Riser Slot 2 Connector (J1A2)
Pin
B1
B2
B3
B4
Pin Name
SMCLK
B6
3.3V Aux
GND
TXD_0
B9
TXD_1
B10
TXD_2
B11
TXD_3
Pin
A1
12V
12V
12V
12V
B5
B7
B8
Description
A2
A3
A4
for rIOM temp
sensor
For DNM & IOM
wake on LAN
RGMII txmit
data
RGMII txmit
data
RGMII txmit
data
RGMII txmit
data
Pin Name
3.3V
3.3V
3.3V
SMDATA
A5
5VAUX
Description
for use by IB rIOM
for rIOM temp sensor
For DNM & IOM wake on
LAN
A6
A7
A8
PRESENT#
RIOM_ACT#
rIOM function present
Drive generic Activity LED
RGMII receive data
RXD_3
A9
RGMII receive data
RXD_2
A10
RGMII receive data
RXD_1
A11
RGMII receive data
RXD_0
KEY
B12
B13
GND
TX_CLK
B14
TX_CTL
Revision 1.4
RGMII txmit
Clock
RGMII txmit
Cntrl
A12
A13
RX_CTL
GND
A14
RGMII receive Cntrl
RGMII receive Clock
RX_CLK
167
Connector/Header Locations and Pin-out
Pin
Pin Name
Intel® Server Board S1600JP TPS
Description
Pin
Pin Name
B15
B16
MDIO
PERST#
A15
A16
MDC
GND
B17
B18
B19
WAKE#
PETxP0
PETxN0
A17
A18
A19
REFCLK+
REFCLKGND
B20
B21
B22
B23
B24
B25
GND
GND
PETxP1
PETxN1
GND
GND
A20
A21
A22
A23
A24
A25
PERxP0
PERxN0
GND
GND
PERxP1
PERxN1
B26
B27
B28
B29
B30
B31
PETxP2
PETxN2
GND
GND
PETxP3
PETxN3
A26
A27
A28
A29
A30
A31
GND
GND
PERxP2
PERxN2
GND
GND
B32
B33
B34
B35
B36
B37
GND
GND
PETxP4
PETxN4
GND
GND
A32
A33
A34
A35
A36
A37
PERxP3
PERxN3
GND
GND
PERxP4
PERxN4
B38
B39
B40
B41
B42
B43
PETxP5
PETxN5
GND
GND
PETxP6
PETxN6
A38
A39
A40
A41
A42
A43
GND
GND
PERxP5
PERxN5
GND
GND
B44
B45
B46
GND
GND
PETxP7
A44
A45
A46
PERxP6
PERxN6
GND
B47
PETxN7
A47
GND
B48
B49
GND
GND
A48
A49
PERxP7
PERxN7
Description
Clock pair 1
Clock pair 1
Table 73. PCI Express* x16 Riser Slot 3 Connector (J1B1 and J1D1)
Side
Even
Pin Name
Side
Odd
12V
60
58
56
54
GND
3.3V
3.3V
59
57
55
53
52
50
gnd
PETxP0
51
49
168
Pin Name
12V
12V
GND
REFCLK1+*
REFCLK1-*
GND
Revision
1.4
Intel® Server Board S1600JP TPS
Side
Even
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2
60
58
56
54
52
50
48
46
44
42
40
38
36
34
32
30
28
26
24
22
20
18
Revision 1.4
Connector/Header Locations and Pin-out
Pin Name
PETxN0
GND
PETxP1
PETxN1
GND
PETxP2
PETxN2
GND
PETxP3
PETxN3
GND
PETxP4
PETxN4
GND
PETxP5
PETxN5
GND
PETxP6
PETxN6
GND
PETxP7
PETxN7
GND
3.3VAUX
WAKE#
PERST#
GND
PETxP8
PETxN8
GND
PETxP9
PETxN9
GND
PETxP10
PETxN10
GND
PETxP11
PETxN11
GND
PETxP12
PETxN12
GND
PETxP13
PETxN13
GND
PETxP14
Side
Odd
47
45
43
41
39
37
35
33
31
29
27
25
23
21
19
17
15
13
11
9
7
5
3
1
59
57
55
53
51
49
47
45
43
41
39
37
35
33
31
29
27
25
23
21
19
17
Pin Name
PERxP0
PERxN0
GND
PERxP1
PERxN1
GND
PERxP2
PERxN2
GND
PERxP3
PERxN3
GND
PERxP4
PERxN4
GND
PERxP5
PERxN5
GND
PERxP6
PERxN6
GND
PERxP7
PERxN7
GND
GND
REFCLK2+*
REFCLK2-*
GND
PERxP8
PERxN8
GND
PERxP9
PERxN9
GND
PERxP10
PERxN10
GND
PERxP11
PERxN11
GND
PERxP12
PERxN12
GND
PERxP13
PERxN13
GND
169
Connector/Header Locations and Pin-out
Intel® Server Board S1600JP TPS
Side
Even
Pin Name
Side
Odd
15
13
11
9
7
6
PETxN14
GND
PETxP15
PETxN15
GND
SMBUS_R4
CLK
4
2
Spare
Spare
3
1
16
14
12
10
8
Pin Name
PERxP14
PERxN14
GND
PERxP15
PERxN15
5
GND
SMBUS_R4
DAT
Riser ID
Notes: There are 2 PCIe clock references from the riser slot: REFCLK1 and REFCLK2. If the riser is designed as 1
x16 PCIe, BIOS will only enable REFCLK1 and disable REFCLK2. If the riser is split to 2 x8 PCIe, both REFCLK1
and REFCLK2 will be enabled for PCIe lane 0~7 and PCIe lane 8~15 respectively.
7.3.2
VGA Connector
The following table details the pin-out definition of the external VGA connector (J5A1) and so on.
Table 74. VGA External Video Connector Pin-Out (J5A1)
Pin
7.3.3
Signal Name
Description
1
CRT_RED
Red (analog color signal R)
2
CRT_GREEN
Green (analog color signal G)
3
CRT_BLUE
Blue (analog color signal B)
4
NC
No connection
5
GND
Ground
6
GND
Ground
7
GND
Ground
8
GND
Ground
9
NC
No connection
10
GND
Ground
11
NC
No connection
12
CRT_DDCDATA
DDCDAT
13
CRT_HSYNC
HSYNC (horizontal sync)
14
CRT_VSYNC
VSYNC (vertical sync)
15
CRT_DDCCLK
DDCCLK
Internal Video for the front video
The following table details the pin-out of the internal video for front connector (J6A1) found on
the back edge of the server board.
Table 75. Internal Video Connector Pin-Out (J6A1)
Pin
1
Signal Name
Red
Pin
2
Signal Name
R_RTN (Red Return)
170
Revision
1.4
Intel® Server Board S1600JP TPS
Pin
7.3.4
Connector/Header Locations and Pin-out
Signal Name
Pin
Signal Name
3
Green
4
G_RTN (Green Return)
5
Blue
6
B_RTN (Blue Return)
7
Vsync
8
GND
9
Hsync
10
KEY
11
DDC_SDA
12
VIDEO_IN_USE signal
13
DDC_SCL
14
+5V (fused, not populated)
NIC Connectors
The server board provides four RJ-45 connectors on the back edge of the board (JA4A1 and
JA3A1). The pin-out for NIC connectors are identical and are defined in the
following table.
Table 76. RJ-45 10/100/1000 NIC Connector Pin-out (JA4A1 and JA3A1)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
7.3.5
Signal Name
NIC_0_0_DP
NIC_0_0_DN
NIC_0_CT1
NIC_0_1_DP
NIC_0_1_DN
NIC_0_CT2
NIC_0_2_DP
NIC_0_2_DN
NIC_0_CT3
NIC_0_3_DP
NIC_0_3_DN
NIC_0_CT4
LED_NIC_LINK0_100_N
LED_NIC_LINK0_1000_R_N
LED_NIC_LINK0_LNKUP_N
LED_NIC_LINK0_ACT_R_N
SATA Connectors
The server board provides six SATA port connectors which including two 6Gb/s SATA ports with
white connectors (J6E1 and J2E2) and four 3Gb/s SATA ports with black connectors (J2E1,
J2E3, J1E3, and J2D3).
SATA_0 (J6E1) can support SATA DOM. The SATA_1 (J2E2) cannot support SATA DOM from
the mechanical fitting with the board.
The pin configuration for each connector is identical and defined in the following table.
Table 77. SATA Connectors Pin-Out (J6E1, J2E2, J2E1, J2E3, J1E3, and J2D3)
Pin
1
Revision 1.4
Signal Name
GND
171
Connector/Header Locations and Pin-out
Intel® Server Board S1600JP TPS
Pin
2
3
4
5
6
7
7.3.6
Signal Name
SATA_TX_DP
SATA_TX_DN
GND
SATA_RX_DN
SATA_RX_DP
GND
Mini SAS Connector
The server board provides one mini SAS port connector (J2D2).
Table 78. Mini SAS Connector Pin-Out (J2D2)
Pin
Signal Name
Pin
Signal Name
A1
GND
B1
GND
A2
RX0_P
B2
TX0_P
A3
RX0_N
B3
TX0_N
A4
GND
B4
GND
A5
RX1_P
B5
TX1_P
A6
RX1_N
B6
TX1_N
A7
GND
B7
GND
A8
BP_TYPE
B8
SGPIO_SAS_CLOCK
A9
GND
B9
SGPIO_SAS_LOAD
A10
SGPIO_SAS_DATAOUT
B10
GND
A11
SGPIO_SAS_DATAIN
B11
CNTRL_TYPE
A12
GND
B12
GND
A13
RX2_P
B13
TX2_P
A14
RX2_N
B14
TX2_N
A15
GND
B15
GND
A16
RX3_P
B16
TX3_P
A17
RX3_N
B17
TX3_N
A18
GND
B18
GND
7.3.7
SATA SGPIO Connector
The server board provides one SATA SGPIO connector (J1E1).
Table 79. SATA SGPIO Connector Pin-Out (J1E1)
Pin
Signal Name
1
SCLOCK
2
SLOAD
3
GND
4
SDOUT0
5
SDOUT1
172
Revision
1.4
Intel® Server Board S1600JP TPS
7.3.8
Connector/Header Locations and Pin-out
Hard Drive Activity (Input) LED Header
Table 80. SATA HDD Activity (Input) LED Header (J6F1)
Pin
Description
1
2
7.3.9
LED_HD_ACTIVE_L
NC
Storage Upgrade Key Connector
The server board provides one SATA/SAS storage upgrade key connector (J3E1) on board.
The Storage Upgrade Key is a small PCB board that has up to two security EEPROMs that are
read by the system ME to enable different versions of LSI* RAID 5 software stack and/or
upgrade from SATA to SAS storage functionality.
The pin configuration of connector is identical and defined in the following table and so on.
Table 81. Storage Upgrade Key Connector Pin-Out (J3E1)
Pin
Signal Description
1
2
3
4
7.3.10
GND
FM_PBG_DYN_SKU_KEY_R
GND
FM_SSB_SAS_SATA_RAID_KEY_R
Serial Port Connectors
The server board provides one internal 9-pin serial A header (J5A2). The following tables define
the pin-outs and so on.
Table 82. Internal Serial Port Connecter Pin-Out (J5A2)
Pin
1
3
5
7
9
7.3.11
Signal Name
SPA_DCD
SPA_SIN_N
SPA_SOUT_N
SPA_DTR
GND
Pin
2
4
6
8
Signal Name
SPA_DSR
SPA_RTS
SPA_CTS
SPA_RI
USB Connectors
The server board provides one two external USB headers, two internal USB connectors and
one type A USB connector.
The following table defines the pin-out of the external USB port connectors (J1A1 and J2A1)
found on the back edge of the server board.
Table 83. External USB port Connector Pin-Out (J1A1 and J2A1)
Pin
1
2
3
Revision 1.4
Signal Name
P5V_AUX
USB2_Px_REAR_DN
USB2_Px_REAR_DP
173
Connector/Header Locations and Pin-out
Intel® Server Board S1600JP TPS
Pin
4
Signal Name
GND
One Type A USB connector on the server board provide an option to support UBS device. The
pin-out is detailed in the following table.
Table 84. Type A USB connector Pin-Out (J1D2)
Pin
Signal Name
1
2
3
4
+5V
USB_N
USB_P
GND
Two 2x5 connectors on the server board provide an option to support four additional internal
USB ports (J6E2 and J2D1). The pin-out is detailed in the following table and so on.
Table 85. Internal USB Connector Pin-Out (J6E2 and J2D1)
Pin
1
3
5
7
9
7.3.12
Signal Name
+5V
USB_N
USB_P
GND
Key Pin
Pin
2
4
6
8
10
Signal Name
+5V
USB_N
USB_P
GND
NC
TPM Connector
The server board provides one TPM connector (J6B2) to support the TPM module. The pin-out
is defined in the following table and so on.
Table 86. TPM Connector Pin-Out (J6B2)
Pin
Signal Name
Pin
Signal Name
1
Key Pin
2
LPC_LAD<1>
3
LPC_LAD<0>
4
GND
5
IRQ_SERIAL
6
LPC_FRAME_N
7
P3V3
8
GND
9
RST_IBMC_NIC_N
10
CLK_33M_TPM
11
LPC_LAD<3>
12
GND
13
GND
14
LPC_LAD<2>
174
Revision
1.4
Intel® Server Board S1600JP TPS
7.3.13
Connector/Header Locations and Pin-out
SSI Front Panel Header
The server board provides one front panel header (J6H1) to support the standard Scythe pin-out
is defined in the following table and so on.
Table 87. SSI Front Panel Header Pin-Out (J6H1)
Pin
7.3.14
SSI Signal name
Pin
SSI Signal Name
1
3
5
7
9
11
13
15
17
19
21
23
SB3.3V
Key
Power LED Cathode
3.3V
HDD Activity LED Cathode
Power Switch
GND (Power Switch)
Reset Switch
GND (Reset/ID/NMI Switch)
System ID Switch
Pull Down
NMI to CPU Switch
2
4
6
8
10
12
14
16
18
20
22
24
SB3.3V
SB5V
System ID LED Cathode
System Fault LED Anode
System Fault LED Cathode
NIC#1 Activity LED
NIC#1 Link LED
2
I C SDA
2
I C SCL
Chassis Intrusion
NIC#2 Activity LED
NIC#2 Link LED
1
3
NIC#3 Activity LED
NIC#3 Link LED
2
4
NIC#4 Activity LED
NIC#4 Link LED
SMB PMBus* Connector
The server board provides one SMB PMBus* Connector (J6H2). The pin-out is defined in the
following table and so on.
Table 88. PMBus* Connector Pin-Out (J6H2)
Pin
7.3.15
Signal Name
1
SMB_PWR_CLK
2
SMB_PWR_DAT
3
SMB_PWR_ALRT
4
GND
5
3.3V RS
HSBP I2C Connector
The server board provides one HSBP I2C connector (J1E2). The pin-out is defined in the
following table and so on.
Table 89. HSBP I2C Connector Pin-Out (J1E2)
Pin
Revision 1.4
Signal Name
1
SMB_HSBP_3V3STBY_DATA
2
GND
3
SMB_HSBP_3V3STBY_CLK
175
Connector/Header Locations and Pin-out
7.4
Intel® Server Board S1600JP TPS
Fan Headers
The server board provides six 8 pin fan headers (J1K1, J1K2, J3K1, J4K2, J6K2, and J6K3).
The following table defined the pin-out.
Table 90. Baseboard Fan Connector Pin-Out (J1K1, J1K2, J3K1, J4K2, J6K2, and J6K3)
Pin
Signal Name
1
7.5
GND
2
12V
3
Tachx
4
PWMy
5
GND
6
12V
7
Tachz
8
PWMy
Fan Domain Mapping
S1600JP has six system fan connector can connector 12 fans. Those system fan connectors
belongs to four fan domains. S1600JP BMC FW can control the fan speed by the fan domain.
Table 91. S1600JP Fan Connctor and Fan Domain Mapping Table
Connector
System Fan
1A
System Fan
1B
System Fan
2A
System Fan
2B
System Fan
3A
System Fan
3B
System Fan
4A
System Fan
4B
System Fan
5A
System Fan
5B
System Fan
6A
System Fan
6B
Layout
Description
Ref.
Description
#
Pins
SYS
FAN_1
J1K1(A)
8
SYS
FAN_2
J1K2(A)
SYS
FAN_3
J3K1(A)
SYS
FAN_4
J4K2(A)
SYS
FAN_5
J6K2(A)
SYS
FAN_6
J6K3(A)
Fan
Domain
Tach
Meter
Sensor
Number
_SDR_Tag
Expected
Max RPM
2
8
30
OTHER_FAN_1A
25000
2
9
31
OTHER_FAN_1B
25000
2
6
32
OTHER_FAN_2A
25000
2
7
33
OTHER_FAN_2B
25000
0
4
34
OTHER_FAN_3A
25000
0
5
35
OTHER_FAN_3B
25000
0
2
36
OTHER_FAN_4A
25000
0
3
37
OTHER_FAN_4B
25000
1
0
38
OTHER_FAN_5A
25000
1
1
39
OTHER_FAN_5B
25000
3
10
3A
OTHER_FAN_6A
25000
3
11
3B
OTHER_FAN_6B
25000
8
8
8
8
8
176
Revision
1.4
Intel® Server Board S1600JP TPS
7.6
Connector/Header Locations and Pin-out
Chassis Intrusion
The Chassis Intrusion header is connected through a two wire cable to a switch assembly that is
mounted just under the chassis cover on systems that support this feature. When the chassis
cover is removed, the switch and thus the electrical connection between the pins on this header
become open allowing the Emulex* PILOT III BMC’s CHASIS_N pin to be pulled LOW. The
Emulex* PILOT III BMC’s CHASIS_N pin is used by Firmware to note the change in the chassis
cover status. Header on baseboard can be unstuffed by default a shorting resistor will be
needed to close the circuit.
Table 92. Chassis Intrusion Header (J6A3)
Header state
PINS 1 and 2 CLOSED
PINS 1 and 2 OPEN
Revision 1.4
Description
BMC CHASIS_N is pulled HIGH. Chassis cover is closed. Default
position.
BMC CHASIS_N is pulled LOW. Chassis cover is removed.
177
Intel® Light-Guided Diagnostics
8.
Intel® Server Board S1600JP TPS
Intel® Light-Guided Diagnostics
Intel® Server Board S1600JP has several onboard diagnostic LEDs to assist in troubleshooting
board-level issues. This section provides a description the location and function of each LED on
the server board.
8.1
Front Panel Support
The Intel® Server Board S1600JP supports the front panel and control signals which are
provided through bridge board.
Each Mini-FP provides the following switch and LED features:
 Power switch with integrated power LED (green): Includes clear button lens but
painted black with laser etched power icon for light to shine through.
 Chassis ID switch with integrated ID LED (blue) Includes clear button lens but
painted black with laser etched ID icon for light to shine through.
 Recessed resets switch with black actuator.
 Bi-color Status/Fault LED (green/amber): Includes a status/fault icon printed on
cosmetic front panel label. Icon should be translucent (only shows when LED is on).
 Single network activity/link LED, hardware baseboard ORs Ethernet and Infiniband*
activity signals together into just one global signal. Includes a network activity/link
icon printed on cosmetic front panel label. Icon should be translucent (only shows
when LED is on).
8.1.1
System ID LED
The server board supports a blue system ID LED on the front panel, which is used to visually
identify a specific server installed among many other similar servers. There are two options
available for illuminating the System ID LED:
1. The front panel ID LED Button is pushed, which causes the LED to illuminate to a solid
on state until the button is pushed again.
2. An IPMI Chassis Identify command is remotely entered, which causes the LED to blink.
The System ID LED on the server board is tied directly to the System ID LED on system front
panel if present.
8.1.2
System Status LED
The server board supports status LED on the front panel, which acts similar to the status of the
LED on the server board.
178
Revision
1.4
Intel® Server Board S1600JP TPS
8.1.3
Intel® Light-Guided Diagnostics
Network Link/Activity LED
The server board provides LED on the front panel for Network Link/Activity. The following table
shows the LED details:
Table 93. Network link/activity LED
LED
Color
LAN Link/Activity
8.2
Green
Green
Condition
On
Blink
Off
What It Means
LAN link/no access
LAN access
Idle
POST Code Diagnostic LEDs
Eight amber POST code diagnostic LEDs are located on the back-left-edge of the server board
in the rear I/O area of the server board by the QSFP connector.
During the system boot process, the BIOS executes a number of platform configuration
processes, each of which is assigned a specific hex POST code number. As each configuration
routine is started, the BIOS displays the given POST code to the POST code diagnostic LEDs
on the back edge of the server board. To assist in troubleshooting a system hang during the
POST process, you can use the Diagnostic LEDs to identify the last POST process executed.
For a complete description of how these LEDs are read and a list of all supported POST codes,
refer to Appendix A.
Figure 50. Rear Panel Diagnostic LEDs (Block A)
Revision 1.4
179
Environmental Limits Specifications
9.
Intel® Server Board S1600JP TPS
Environmental Limits Specifications
Operation of the server board at conditions beyond those shown in the following table may
cause permanent damage to the system. Exposure to absolute maximum rating conditions for
extended periods may affect long term system reliability.
Note: The Energy Star compliance is at the systems level and not the board level. Use of Intel®
boards alone does not guarantee Energy Star compliance.
Table 94. Server Board Design Specifications
1
Operating Temperature
0ºC to 55ºC (32ºF to 131ºF) at product airflow
specification
Non-Operating Temperature
-40ºC to 70ºC (-40ºF to 158ºF)
DC Voltage
± 5% of all nominal voltages
Shock (Unpackaged)
Trapezoidal, 50 G, 170 inches/sec
Shock (Packaged)
<20 pounds
>= 20 to <40 pounds
>= 40 to <80 pounds
>= 80 to <100 pounds
>= 100 to <120 pounds
>= 120 pounds
36 inches
30 inches
24 inches
18 inches
12 inches
9 inches
Vibration (Unpackaged)
5 Hz to 500 Hz 3.13 g RMS random
Note:
®
®
Chassis design must provide proper airflow to avoid exceeding the Intel Xeon processor maximum case temperature.
Disclaimer Note: Intel® ensures the unpackaged server board and system meet the shock
requirement mentioned above through its own chassis development and system configuration. It
is the responsibility of the system integrator to determine the proper shock level of the board
and system if the system integrator chooses different system configuration or different chassis.
Intel Corporation cannot be held responsible, if components fail or the server board does not
operate correctly when used outside any of its published operating or non-operating limits.
180
Revision
1.4
Intel® Server Board S1600JP TPS
9.1
Environmental Limits Specifications
Processor Thermal Design Power (TDP) Support
To allow optimal operation and long-term reliability of Intel® processor-based systems, the
processor must remain within the defined minimum and maximum case temperature (TCASE)
specifications. Thermal solutions not designed to provide sufficient thermal capability may affect
the long-term reliability of the processor and system. The server board is designed to support
the Intel® Xeon® Processor E5-2600 product family TDP guidelines up to and including 135W or
Intel® Xeon® Processor E5-1600 product family TDP guidelines up to and including 130W.
Disclaimer Note: Intel Corporation server boards contain a number of high-density VLSI and
power delivery components that need adequate airflow to cool. Intel® ensures through its own
chassis development and testing that when Intel® server building blocks are used together, the
fully integrated system will meet the intended thermal requirements of these components. It is
the responsibility of the system integrator who chooses not to use Intel® developed server
building blocks to consult vendor datasheets and operating parameters to determine the amount
of airflow required for their specific application and environmental conditions. Intel Corporation
cannot be held responsible, if components fail or the server board does not operate correctly
when used outside any of their published operating or non-operating limits.
Revision 1.4
181
Power Supply Specification Guidelines
Intel® Server Board S1600JP TPS
10. Power Supply Specification Guidelines
This section provides power supply specification guidelines recommended for providing the
specified server platform with stable operating power requirements. And the introduction of how
to power ON the server with standard SSI ATX or EPS power supply.
Note: The power supply data provided in this section is for reference purposes only. It reflects
Intel®’s own AC power out requirements for a 750W power supply as used in an Intel® designed
1U server platform. The intent of this section is to provide customers with a guide to assist in
defining and/or selecting a power supply for custom server platform designs that utilize the
server boards detailed in this document.
10.1 Power Supply DC Output Connector
To facilitate customers who want to cable to this board from a power supply, the power
connectors are implemented through one 10-pin connector and one 8-pin connector.
Table 95. Main Power Supply Connector 1 (10-pin 2x5) Connector Pin-Out
Pin
Signal Name
1
2
3
4
5
PSON
GND
GND
GND
5V
Pin
Signal Name
6
7
8
9
10
5VSB
PWROK
3.3V
3.3V
Reserved
Table 96. Main Power Supply Connector 2 (8-pin 2x4) Connector Pin-Out
Pin
Signal Name
1
2
3
4
Pin
GND
GND
GND
GND
Signal Name
5
6
7
8
+12V
+12V
+12V
+12V
10.2 Power Supply DC Output Specification
10.2.1
Output Power/Currents
The following tables define the minimum power and current ratings. The power supply must
meet both static and dynamic voltage regulation requirements for all conditions.
Table 97. 750W Minimum Load Ratings
Parameter
12V main
12Vstby
Min
0.0
0.0
Max.
Peak 1, 2
62.0
2.1
70.0
2.4
Unit
A
A
Notes:
1.
12Vstby must provide 4.0A with two power supplies in parallel. The Fan may work when stby
current >1.5A.
182
Revision
1.4
Intel® Server Board S1600JP TPS
2.
10.2.2
Power Supply Specification Guidelines
Length of time peak power can be supported is based on thermal sensor and assertion of the SMBAlert#
signal. Minimum peak power duration shall be 20 seconds without asserting the SMBAlert# signal at
maximum operating temperature.
Standby Output
The standby output shall be present when an AC input greater than the power supply turn on
voltage is applied. There should be load sharing in the standby rail.
10.2.3
Voltage Regulation
The power supply output voltages must stay within the following voltage limits when operating at
steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.
These shall be measured at the output connectors.
Table 98. 750W Voltage Regulation Limits
Parameter
+12V
+12V stby
10.2.4
Tolerance
- 5%/+5%
- 5%/+5%
Min
Nom
+11.40
+11.40
+12.00
+12.00
Max
Units
+12.60
+12.60
Vrms
Vrms
Dynamic Loading
The output voltages shall remain within limits specified for the step loading and capacitive
loading specified in the following table. The load transient repetition rate shall be tested between
50Hz and 5kHz at duty cycles ranging from 10%-90%. The  load transient repetition rate is only
a test specification. The step load may occur anywhere within the MIN load to the MAX
load conditions.
Table 99. 750W Transient Load Requirements
Output
 Step Load Size
Load Slew Rate
+12VSB
1.0A
+12V
60% of max load
Note: For dynamic condition +12V min loading is 1A.
10.2.5
0.25 A/sec
0.25 A/sec
Test capacitive Load
20 F
2000 F
Capacitive Loading
The power supply shall be stable and meet all requirements with the following capacitive loading
ranges.
Table 100. 750W Capacitive Loading Conditions
Output
+12VSB
+12V
10.2.6
MIN
20
500
MAX
3100
25000
Units
F
F
Grounding
The output ground of the pins of the power supply provides the output power return path. The
output connector ground pins shall be connected to the safety ground (power supply enclosure).
This grounding should be well designed to ensure passing the max allowed Common Mode
Noise levels.
Revision 1.4
183
Power Supply Specification Guidelines
Intel® Server Board S1600JP TPS
The power supply shall be provided with a reliable protective earth ground. All secondary
circuits shall be connected to protective earth ground. Resistance of the ground returns to
chassis shall not exceed 1.0 m. This path may be used to carry DC current.
10.2.7
Closed loop stability
The power supply shall be unconditionally stable under all line/load/transient load conditions
including specified capacitive load ranges. A minimum of 45 degrees phase margin and 10dBgain margin is required. Closed-loop stability must be ensured at the maximum and minimum
loads as applicable.
10.2.8
Residual Voltage Immunity in Standby mode
The power supply should be immune to any residual voltage placed on its outputs (typically a
leakage voltage through the system from standby output) up to 500mV. There shall be no
additional heat generated, nor stressing of any internal components with this voltage applied to
any individual or all outputs simultaneously. It also should not trip the protection circuits during
turn on.
The residual voltage at the power supply outputs for no load condition shall not exceed 100mV
when AC voltage is applied and the PSON# signal is de-asserted.
10.2.9
Common Mode Noise
The Common Mode noise on any output shall not exceed 350mV pk-pk over the frequency
band of 10Hz to 20MHz.
10.2.10
Soft Starting
The Power Supply shall contain control circuit which provides monotonic soft start for its outputs
without overstress of the AC line or any power supply components at any specified AC line or
load conditions.
10.2.11
Zero Load Stability Requirements
When the power subsystem operates in a no load condition, it does not need to meet the output
regulation specification, but it must operate without any tripping of over-voltage or other fault
circuitry. When the power subsystem is subsequently loaded, it must begin to regulate and
source current without fault.
10.2.12
Hot Swap Requirements
Hot swapping a power supply is the process of inserting and extracting a power supply from an
operating power system. During this process the output voltages shall remain within the limits
with the capacitive load specified. The hot swap test must be conducted when the system is
operating under static, dynamic, and zero loading conditions. The power supply shall use a
latching mechanism to prevent insertion and extraction of the power supply when the AC power
cord is inserted into the power supply.
10.2.13
Forced Load Sharing
The +12V output will have active load sharing. The output will share within 10% at full load. The
failure of a power supply should not affect the load sharing or output voltages of the other
supplies still operating. The supplies must be able to load share in parallel and operate in a hot184
Revision
1.4
Intel® Server Board S1600JP TPS
Power Supply Specification Guidelines
swap/redundant 1+1 configurations. The 12VSB output is not required to actively share current
between power supplies (passive sharing). The 12VSB output of the power supplies are
connected together in the system so that a failure or hot swap of a redundant power supply
does not cause these outputs to go out of regulation in the system.
10.2.14
Ripple/Noise
The maximum allowed ripple/noise output of the power supply is defined in the following table.
This is measured over a bandwidth of 10Hz to 20MHz at the power supply output connectors. A
10F tantalum capacitor in parallel with a 0.1F ceramic capacitor is placed at the point
of measurement.
Table 101. 750W Ripples and Noise
10.2.15
+12V main
+12VSB
120mVp-p
120mVp-p
Timing Requirement
These are the timing requirements for the power supply operation. The output voltages must rise
from 10% to within regulation limits (Tvout_rise) within 5ms to 70ms. For 12VSB, it is allowed to
rise from 1.0ms to 25ms. All outputs must rise monotonically. The following table shows the
timing requirements for the power supply being turned on and off through the AC input, with
PSON held low and the PSON signal, with the AC input applied.
Table 102. 750W Timing Requirements
Item
Tvout_rise
Tsb_on_delay
Tac_on_delay
Tvout_holdup
Tpwok_holdup
Tpson_on_delay
Tpson_pwok
Tpwok_on
Tpwok_off
Tpwok_low
Tsb_vout
T12VSB_holdup
Description
Output voltage rise time.
Delay from AC being applied to 12VSB being within
regulation.
Delay from AC being applied to all output voltages being
within regulation.
Time 12Vl output voltage stay within regulation after loss
of AC.
Delay from loss of AC to de-assertion of PWOK.
Delay from PSON# active to output voltages within
regulation limits.
Delay from PSON# deactivate to PWOK being deasserted.
Delay from output voltages within regulation limits to
PWOK asserted at turn on.
Delay from PWOK de-asserted to output voltages
dropping out of regulation limits.
Duration of PWOK being in the de-asserted state during
an off/on cycle using AC or the PSON signal.
Delay from 12VSB being in regulation to O/Ps being in
regulation at AC turn on.
Time the 12VSB output voltage stays within regulation
after loss of AC.
Min
5.0 *
Max
70 *
1500
ms
ms
3000
ms
13
12
5
100
Units
ms
400
ms
ms
5
ms
500
ms
1
ms
100
ms
50
70
1000
ms
ms
Note:
* The 12VSB output voltage rise time shall be from 1.0ms to 25ms.
Revision 1.4
185
Power Supply Specification Guidelines
Intel® Server Board S1600JP TPS
AC Input
Tvout_holdup
Vout
Tpwok_low
TAC_on_delay
Tsb_on_delay
Tpwok_on
PWOK
12Vsb
Tpwok_off
Tsb_on_delay
Tpwok_on
Tpwok_holdup
Tsb_vout
Tpwok_off
Tpson _pwok
T5Vsb_holdup
Tpson_on_delay
PSON
AC turn on/off cycle
PSON turn on/off cycle
Figure 51. 750W Turn On/Off Timing (Power Supply Signals)
10.3 Power ON the Server Board with ATX or EPS Power Supply
S1600JP has two main power connectors and one PMbus* connector for PSU management.
Figure 52. Main Power Connector 1, 2 and PMbus Connector
S1600JP can work with the power supply which follows the standard SSI specification. The
power supply can be ATX or EPS form factor, and need one power adapter cable to convert
186
Revision
1.4
Intel® Servver Board S16
600JP TPS
Power Suppply Specificatioon Guidelines
power ssupply P1 Conn(2X12p
C
in baseboarrd power co
onnector) to 2X5 pin connector which can
be conn
nected to S1
1600JP main power connector 1. The
T other 2X
X4 pin powe
er connecto
or from
power ssupply can connect
c
to S
S1600JP ma
ain power connector 2 directly.
Figure 53. 2X12pin to 2X5 pin Power
P
Adap
pter Cable

2X1
12 pin conne
ector pin-ou
ut
Figure 54. 2X12 Power Conn
nector Pin Number
N
Revision 1.4
18
87
Power Supply Specificattion Guideliness
Intel® S
Server Board S
S1600JP TPS
Table
e 103. 2X12 Pin Power C
Connector P
Pin-Out
Pin
Signal Name
18 AWG Co
olor
Pin
12
24
11
23
10
22
9
5VSB
Purple
21
8
PWROK
Gray
20
7
GND
Black
19
6
18 AW
WG Color
PSON
Greenn
+3.3V
Orang
ge
18
5
GND
Black
17
4
+5V
Red
16
3
GND
Black
15
2
+3.3V
Orange
14
1

Signal Naame
13
5 pin connecctor pin-out
2X5
Figure 55. 2X5 Pin
n Number
T
Table 104. 2X5 Pin Conn
nector Pin-O
Out
Pin
Sig
gnal Name
18 AWG coolor
Pin
Signal Naame
18 AWG color
1
PS
SON
Green
6
5VSB
Purple
2
GN
ND
Black
7
PWROK
Gray
3
GN
ND
Black
8
+3.3V
Orange
4
GN
ND
Black
9
+3.3V
Orange
5
+5
5V
Red
10
188
Revision
1.4
Intel® Servver Board S16
600JP TPS

Power Suppply Specificatioon Guidelines
2X1
12 connecto
or to 2X5 co
onnector ma
apping tab
Table 105.. 2X12 Pin to
o 2X5 Pin Co
onnector Ma
apping Table
e
Connecct the powerr adapter ca
able 2X12 piin connecto
or to power ssupply P1 Conn(2X12p
C
pin
baseboa
ard power cconnector) and
a connectt the other side
s
to S160
00JP main p
power 1. Co
onnect
power ssupply P2 C
Conn (2X4 p
pin processo
or/memory p
power connector) to S1
1600JP main power 2,
and then the serverr board is re
eady to be power
p
ON.
an be powerr ON/OFF by momentary short the front panell Pin 11 and
d Pin 13.
S1600JP server ca
Figure 56. F
Front Panel Pin 11 and 1
13
Revision 1.4
18
89
Appendix A: Integration and Usage Tips
Intel® Server Board S1600JP TPS
Appendix A: Integration and Usage Tips

When adding or removing components or peripherals from the server board, AC power
must be removed. With AC power plugged into the server board, 5-V standby is still
present even though the server board is powered off.

This server board supports the Intel® Xeon® Processor E5-2600 product family with a
Thermal Design Power (TDP) of up to and including 135 Watts or Intel® Xeon®
Processor E5-1600 product family with a Thermal Design Power (TDP) of up to and
including 130 Watts. Previous generations of the Intel® Xeon® processors are not
supported.

The server board includes a pre-installed CPU power cable harness. The cable harness
must be installed and fully seated in each connector for the server board to operate.

On the back edge of the server board are eight diagnostic LEDs that display a sequence
of amber POST codes during the boot process. If the server board hangs during POST,
the LEDs display the last POST event run before the hang.

This server board only supports registered DDRIII DIMMs (RDIMMs) and unbuffered
DDRIII DIMMs (UDIMMs). Mixing of RDIMMs and UDIMMs is not supported.

The Intel® Remote Management Module 4 (Intel® RMM4) connector is not compatible
with any previous versions of the Intel® Remote Management Module (Product Order
Code – AXXRMM, AXXRMM2, and AXXRMM3).

Clear the CMOS with AC power cord plugged. Removing the AC power before
performing the CMOS clear operation causes the system to automatically power up and
immediately power down after the CMOS clear procedure is followed and AC power is
re-applied. If this happens, remove the AC power cord, wait 30 seconds, and then reconnect the AC power cord. Power up the system and proceed to the <F2> BIOS Setup
utility to reset the desired settings.

Normal Integrated BMC functionality is disabled with the BMC Force Update jumper set
to the “enabled” position (pins 2-3). The server should never be run with the BMC Force
Update jumper set in this position and should only be used when the standard firmware
update process fails. This jumper should remain in the default (disabled) position (pins 12) when the server is running normally.
When performing a normal BIOS update procedure, the BIOS recovery jumper must be
set to its default position (pins 1-2).

190
Revision
1.4
Intel® Server Board S1600JP TPS
Appendix B: Integration BMC Sensor Tables
Appendix B: Integrated BMC Sensor Tables
This appendix lists the sensor identification numbers and information about the sensor type,
name, supported thresholds, assertion and de-assertion information, and a brief description of
the sensor purpose. See the Intelligent Platform Management Interface Specification, Version
2.0, for sensor and event/reading-type table information.

Sensor Type
The Sensor Type values are the values enumerated in the Sensor Type Codes table in
the IPMI specification. The Sensor Type provides the context in which to interpret the
sensor, such as the physical entity or characteristic that is represented by this sensor.

Event/Reading Type
The Event/Reading Type values are from the Event/Reading Type Code Ranges and
Generic Event/Reading Type Codes tables in the IPMI specification. Digital sensors are
a specific type of discrete sensor, which have only two states.

Event Offset/Triggers
Event Thresholds are event-generating thresholds for threshold types of sensors.
[u,l][nr,c,nc]: upper non-recoverable, upper critical, upper non-critical, lower nonrecoverable, lower critical, lower non-critical
- uc, lc: upper critical, lower critical
Event Triggers are supported event-generating offsets for discrete type sensors. The
offsets can be found in the Generic Event/Reading Type Codes or Sensor Type Codes
tables in the IPMI specification, depending on whether the sensor event/reading type is
generic or a sensor-specific response.
-

Assertion/De-assertion Enables
Assertion and de-assertion indicators reveal the type of events the sensor generates:

- As: Assertions
- De: De-assertion
Readable Value/Offsets

Readable Value indicates the type of value returned for threshold and other nondiscrete type sensors.
- Readable Offsets indicate the offsets for discrete sensors that are readable with the
Get Sensor Reading command. Unless otherwise indicated, all event triggers are
readable; Readable Offsets consist of the reading type offsets that do not generate
events.
Event Data
-
Event data is the data that is included in an event message generated by the sensor. For
threshold-based sensors, the following abbreviations are used:
-
R: Reading value
T: Threshold value
Revision 1.4
191
Appendix B: Integration BMC Sensor Tables

Intel® Server Board S1600JP TPS
Rearm Sensors
The rearm is a request for the event status for a sensor to be rechecked and updated
upon a transition between good and bad states. Rearming the sensors can be done
manually or automatically. This column indicates the type supported by the sensor. The
following abbreviations are used to describe a sensor:

- A: Auto-rearm
- M: Manual rearm
Default Hysteresis
The hysteresis setting applies to all thresholds of the sensor. This column provides the
count of hysteresis for the sensor, which can be 1 or 2 (positive or negative hysteresis).

Criticality
Criticality is a classification of the severity and nature of the condition. It also controls the
behavior of the Control Panel Status LED.

Standby
Some sensors operate on standby power. These sensors may be accessed and/or
generate events when the main (system) power is off, but AC power is present.
192
Revision
1.4
Intel® Server Board S1600JP TPS
Appendix B: Integration BMC Sensor
Tables
Note: All sensors listed as follows may not be present on all platforms. Please check platform EPS section for platform applicability and platform chassis section
for chassis specific sensors. Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or
power supply).
Table 106. BMC Core Sensors
Full Sensor
Name
Sensor
#
Platform
Applicability
Sensor
Type
(Sensor name
in SDR)
Power Unit
Status
(Pwr Unit
Status)
01h
All
Power
Unit
09h
Event/
Reading
Type
Sensor
Specific
6Fh
Event Offset
Triggers
Contrib. To
System Status
00 - Power
down
OK
02 - 240 VA
power
down
Fatal
04 - A/C lost
OK
05 - Soft power
control
failure
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
As and De
–
Trig Offset
A
X
As
–
Trig Offset
M
X
Fatal
06 - Power unit
failure
00 - Fully
Redundant
01 -
OK
Degraded
Redundan
cy lost
Power Unit
Redunda
Note1
ncy
(Pwr Unit
Redund)
Revision 1.4
02 02h
Chassisspecific
Power
Unit
09h
Generic
0Bh
Degraded
Redundan
cy
degraded
03 - Nonredundant:
sufficient
resources.
Transition
from full
redundant
state.
Degraded
193
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
04 – Nonredundant:
sufficient
resources.
Transition
from
insufficient
state.
Degraded
05 - Nonredundant:
insufficient
resources
Fatal
06 –
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Degraded
Redundant
: degraded
from fully
redundant
state.
07 –
Degraded
Redundant
: Transition
from nonredundant
state.
00 - Timer
expired,
status only
IPMI
Watchdog
(IPMI
Watchdog)
03h
All
Watchdog
2
23h
01 - Hard reset
Sensor
Speci 02 - Power
fic
down
6Fh
03 - Power
cycle
OK
As
–
Trig Offset
08 - Timer
interrupt
194
Revision 1.4
A
X
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Physical
Security
(Physical
Scrty)
FP Interrupt
(FP NMI Diag
Int)
04h
05h
Chassis
Intrusion is
chassisspecific
Chassis specific
System Event
Log
(System Event
Log)
System Event
(System
Event)
Button Sensor
(Button)
Revision 1.4
06h
07h
All
All
All
09h
All
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
00 - Chassis
Sensor
intrusion
Speci
fic
04 - LAN leash
6Fh
lost
Degraded
OK
As and De
–
Trig Offset
A
X
Critical
Interr
upt
13h
00 - Front
Sensor
panel
Speci
NMI/diagn
fic
ostic
6Fh
interrupt
OK
As
–
Trig Offset
A
–
Fatal
As and De
–
Trig Offset
A
–
OK
As
–
Trig Offset
A
X
OK
As
-
Trig Offset
A
X
OK
AS
_
Trig Offset
A
X
Time
out
F3h
Event
Loggi
ng
Disa
bled
10h
System
Event
08h
Event Offset
Triggers
Physical
Secu
rity
05h
SMI
SMI Timeout
(SMI Timeout)
Event/
Reading
Type
12h
utton/Switch
14h
Digital
Discr
ete
03h
Sensor
Speci
fic
6Fh
Sensor
Specific
01 – State
asserted
02 - Log area
reset/clear
ed
– PEF action
6Fh
Sensor
Specific
6Fh
– Power Button
02 – Reset
Button
195
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
BMC
Watchdog
Voltage
Regulator
Watchdog
(VR
Watchdog)
0Ah
0Bh
All
All
Mgmt
Syste
m
Healt
h
28h
Voltage
02h
Event/
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Event Offset
Triggers
Contrib. To
System Status
Digital
Discr
ete
03h
01 – State
Asserted
Degraded
As
–
Trig Offset
A
-
Digital
Discr
ete
03h
01 – State
Asserted
Fatal
As and De
–
Trig Offset
M
X
As and De
–
Trig Offset
A
–
Reading
Type
00 - Fully
redundant
OK
01 Redundan
cy lost
Degraded
Redundan
cy
degraded
Degraded
02 -
Fan
Redunda
1
ncy
(Fan
Redundancy)
0Ch
Chassisspecific
Fan
04h
Generic
0Bh
03 - Nonredundant:
Sufficient
resources.
Transition
from
redundant
Degraded
04 - Nonredundant:
Sufficient
resources. Degraded
Transition
from
insufficient.
196
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
SSB Thermal
Trip
(SSB Therm
Trip)
IO Module
Presence
(IO Mod
Presence)
0Dh
All
Event/
Reading
Type
Temperat
ure
Digital
Discrete
01h
03h
Event Offset
Triggers
Contrib. To
System Status
05 - Nonredundant:
insufficient
resources.
Non-Fatal
06 – NonRedundant
: degraded
from fully
redundant.
Degraded
07 - Redundant
degraded
from nonredundant
Degraded
01 – State
Asserted
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Fatal
As and De
–
Trig Offset
M
X
0Eh
Platformspecific
Module/B
oard
15h
Digital
Discrete
08h
01 –
Inserted/Pr
esent
OK
As and De
–
Trig Offset
M
-
SAS Module
Presence
(SAS Mod
Presence)
0Fh
Platformspecific
Module/B
oard
15h
Digital
Discrete
08h
01 –
Inserted/Pr
esent
OK
As and De
–
Trig Offset
M
X
BMC
Firmware
Health
(BMC FW
Health)
10h
All
Mgmt
Health
28h
Sensor
Specific
6Fh
As
-
Trig Offset
A
X
System
Airflow
(System
Airflow)
11h
All
Other
Units
0Bh
Threshold
01h
–
Analog
–
–
–
Revision 1.4
04 – Sensor
Failure
Degraded
–
–
197
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
FW Update
Status
12h
All
Event/
Reading
Type
Version
Change
2Bh
OEM
defined
x70h
Event Offset
Triggers
00hUpdate
started
01hUpdate
completed
successfully.
02hUpdate
failure
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
OK
As
_
Trig Offset
A
_
OK
As and De
–
Trig Offset
M
-
IO Module2
Presence
(IO Mod2
Presence)
13h
Platformspecific
Module/B
oard
15h
Digital
Discrete
08h
Baseboard
Temperat
ure 5
(Platform
Specific)
14h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Baseboard
Temperat
ure 6
(Platform
Specific)
15h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
IO Module2
Temperat
ure
(I/O Mod2
Temp)
16h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
PCI Riser 3
Temperat
ure
(PCI Riser 5
Temp)
17h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
198
01 –
Inserted/Pr
esent
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
PCI Riser 4
Temperat
ure
(PCI Riser 4
Temp)
18h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Baseboard
+1.05V
Processor
3 Vccp
(BB
+1.05Vccp
P3)
19h
Platformspecific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.05V
Processor
4 Vccp
(BB
+1.05Vccp
P4)
1Ah
Platformspecific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
Temperat
ure 1
(Platform
Specific)
20h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Front Panel
Temperat
ure
(Front Panel
Temp)
21h
All
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
22h
All
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
SSB
Temperat
ure
(SSB
Temp)
Revision 1.4
199
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Baseboard
Temperat
ure 2
(Platform
Specific)
23h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Baseboard
Temperat
ure 3
(Platform
Specific)
24h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Baseboard
Temperat
ure 4
(Platform
Specific)
25h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
IO Module
Temperat
ure
(I/O Mod
Temp)
26h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
PCI Riser 1
Temperat
ure
(PCI Riser 1
Temp)
27h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
IO Riser
Temperat
ure
(IO Riser
Temp)
28h
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
200
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Hot-swap
Backplan
e1
Temperature
(HSBP 1
Temp)
29h
Chassisspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Hot-swap
Backplan
e2
Temperature
(HSBP 2
Temp)
2Ah
Chassisspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Hot-swap
Backplan
e3
Temperature
(HSBP 3
Temp)
2Bh
Chassisspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
PCI Riser 2
Temperat
ure
(PCI Riser 2
Temp)
2Ch
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
SAS Module
Temperat
ure
(SAS Mod
Temp)
2Dh
Platformspecific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
2Eh
Chassis
and
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Exit Air
Temperat
ure
(Exit Air
Temp)
Revision 1.4
201
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Platform
Intel® Server Board S1600JP TPS
Sensor
Type
Fan
Tachomet
er
Sensors
(Chassis
specific
sensor
names)
Fan Present
Sensors
(Fan x
Present)
Power Supply
1 Status
Note2
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
[l] [c,nc]
nc = Degraded
c = NonNote3
fatal
As and De
Analog
R, T
M
-
01 - Device
inserted
OK
As and De
-
Triggered
Offset
Auto
-
As and De
–
Trig Offset
A
X
As and De
–
Trig Offset
A
X
Applicability
2Fh
All
Temperat
ure
01h
Threshold
01h
[u,l] [c,nc]
30h–3Fh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
40h–4Fh
Chassis
and
Platform
Specific
Fan
04h
Generic
08h
(Sensor name
in SDR)
Network
Interface
Controller
Temperat
ure
(LAN NIC
Temp)
Event/
Sensor
#
50h
Chassisspecific
(PS1 Status)
Power
Supply
08h
Reading
Type
Sensor
Specific
6Fh
Event Offset
Triggers
00 - Presence
OK
01 - Failure
Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost
Degraded
Note2
Rearm
Stand
-by
06 –
Configurati
on error
Power Supply
2 Status
Contrib. To
System Status
51h
(PS2 Status)
202
Chassisspecific
Power
Supply
08h
Sensor
Specific
6Fh
OK
00 - Presence
OK
01 - Failure
Degraded
02 – Predictive
Failure
Degraded
03 - A/C lost
Degraded
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
06 –
Configurati
on error
OK
Power Supply
1
AC Power
Input
(PS1 Power
In)
54h
Chassisspecific
Other
Units
0Bh
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Power Supply
2
AC Power
Input
(PS2 Power
In)
55h
Chassisspecific
Other
Units
0Bh
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Power Supply
1 +12V %
of
Maximum
Current
Output
(PS1 Curr
Out %)
58h
Chassisspecific
Current
03h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Power Supply
2 +12V %
of
Maximum
Current
Output
(PS2 Curr
Out %)
59h
Chassisspecific
Current
03h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
X
Revision 1.4
203
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Power Supply
1
Temperat
ure
(PS1
Temperature)
Power Supply
2
Temperat
ure
(PS2
Temperature)
5Ch
5Dh
Chassisspecific
Chassisspecific
Temperat
ure
01h
Temperat
ure
Event/
Reading
Type
Threshold
01h
Threshold
01h
Event Offset
Triggers
60h
–
68h
Chassisspecific
[u] [c,nc]
Hot Swap
Controller
1-3
Status
(HSC 1 - 3
Status)
69h
6Bh
Chassisspecific
Processor 1
Status
(P1 Status)
70h
All
Processor 2
Status
(P2 Status)
71h
Processor 3
Status
(P3 Status)
72h
204
All
Platformspecific
Readable
Event
Rearm
De-assert
Value/
Offsets
Data
As and De
Analog
R, T
A
X
As and De
Analog
R, T
A
X
As and De
–
Trig Offset
A
X
X
As and De
–
Trig Offset
A
X
As and De
–
Trig Offset
M
X
As and De
–
Trig Offset
M
X
As and De
–
Trig Offset
M
X
Stand
-by
nc = Degraded
c = Non-fatal
[u] [c,nc]
OK
Sensor
Specific
6Fh
01- Drive Fault
Microcont
roller 16h
Discrete
0Ah
04- transition to
Off Line
Processor
07h
Sensor
Specific
6Fh
01 - Thermal
trip
Fatal
07 - Presence
OK
Processor
07h
Sensor
Specific
6Fh
01 - Thermal
trip
Fatal
Processor
07h
Sensor
Specific
6Fh
01 - Thermal
trip
Fatal
07 - Presence
OK
Drive Slot
0Dh
Assert/
nc = Degraded
c = Non-fatal
00 - Drive
Presence
Hard Disk
Drive 17 23 Status
(HDD 17 - 23
Status)
Contrib. To
System Status
Degraded
07 Rebuild/Re
map in
progress
07 - Presence
Degraded
Degraded
OK
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Processor 4
Status
(P4 Status)
73h
Processor 1
Thermal
Margin
(P1 Therm
Margin)
Event/
Reading
Type
Event Offset
Triggers
01 - Thermal
trip
Fatal
07 - Presence
OK
Platformspecific
Processor
07h
Sensor
Specific
6Fh
74h
All
Temperat
ure
01h
Threshold
01h
-
Processor 2
Thermal
Margin
(P2 Therm
Margin)
75h
All
Temperat
ure
01h
Threshold
01h
Processor 3
Thermal
Margin
(P3 Therm
Margin)
76h
Platformspecific
Temperat
ure
01h
Processor 4
Thermal
Margin
(P4 Therm
Margin)
77h
Platformspecific
Processor 1
Thermal
Control %
(P1 Therm
Ctrl %)
Processor 2
Thermal
Control %
(P2 Therm
Ctrl %)
Revision 1.4
78h
79h
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
As and De
–
Trig Offset
M
X
-
-
Analog
R, T
A
–
-
-
-
Analog
R, T
A
–
Threshold
01h
-
-
-
Analog
R, T
A
–
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
All
Temperat
ure
01h
Threshold
01h
As and De
Analog
Trig Offset
A
–
All
Temperat
ure
01h
As and De
Analog
Trig Offset
A
–
Threshold
01h
nc = Degraded
c = Non-fatal
[u] [c,nc]
nc = Degraded
c = Non-fatal
[u] [c,nc]
205
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Processor 3
Thermal
Control %
(P3 Therm
Ctrl %)
7Ah
Event/
Reading
Type
Platformspecific
Temperat
ure
01h
Threshold
01h
Threshold
01h
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
Rearm
De-assert
Value/
Offsets
Data
As and De
Analog
Trig Offset
A
–
As and De
Analog
Trig Offset
A
–
Stand
-by
nc = Degraded
c = Non-fatal
[u] [c,nc]
nc = Degraded
c = Non-fatal
Processor 4
Thermal
Control %
(P4 Therm
Ctrl %)
7Bh
Platformspecific
Temperat
ure
01h
Processor 1
ERR2
Timeout
(P1 ERR2)
7Ch
All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and De
–
Trig Offset
A
–
Processor 2
ERR2
Timeout
(P2 ERR2)
7Dh
All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and De
–
Trig Offset
A
–
Processor 3
ERR2
Timeout
(P3 ERR2)
7Eh
Platformspecific
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and De
–
Trig Offset
A
–
Processor 4
ERR2
Timeout
(P4 ERR2)
7Fh
Platformspecific
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and De
–
Trig Offset
A
–
Catastrophic
Error
(CATERR)
80h
All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and De
–
Trig Offset
M
–
Processor1
MSID
Mismatch
(P1 MSID
Mismatch)
81h
All
Processor
07h
Digital
Discrete
03h
01 – State
Asserted
Fatal
As and De
–
Trig Offset
M
–
206
[u] [c,nc]
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Platform
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
Event/
Sensor
#
Applicability
Processor
Populatio
n Fault
(CPU Missing)
82h
All
Processor
07h
Digital
Discrete
03h
Processor 1
DTS
Thermal
Margin
(P1 DTS
Therm Mgn)
83h
All
Temperat
ure
01h
Threshold
01h
Processor 2
DTS
Thermal
Margin
(P2 DTS
Therm Mgn)
84h
All
Temperat
ure
01h
Processor 3
DTS
Thermal
Margin
(P3 DTS
Therm Mgn)
85h
All
Processor 4
DTS
Thermal
Margin
(P4 DTS
Therm Mgn)
86h
Processor2
MSID
Mismatch
(P2 MSID
Mismatch)
87h
(Sensor name
in SDR)
Revision 1.4
Reading
Type
Event Offset
Triggers
01 – State
Asserted
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Fatal
As and De
–
Trig Offset
M
–
-
-
-
Analog
R, T
A
–
Threshold
01h
-
-
-
Analog
R, T
A
–
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
All
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
All
Processor
07h
Digital
Discrete
03h
Fatal
As and De
–
Trig Offset
M
–
01 – State
Asserted
207
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Processor 1
VRD
Temperat
ure
(P1 VRD Hot)
90h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
Processor 2
VRD
Temperat
ure
(P2 VRD Hot)
91h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
92h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
93h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
94h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
Processor 3
VRD
Temperat
ure
(P3 VRD Hot)
Processor 4
VRD
Temperat
ure
(P4 VRD Hot)
Processor 1
Memory
VRD Hot
0-1
(P1 Mem01
VRD Hot)
Processor 1
Memory
VRD Hot
2-3
(P1 Mem23
VRD Hot)
95h
208
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Processor 2
Memory
VRD Hot
0-1
(P2 Mem01
VRD Hot)
Processor 2
Memory
VRD Hot
2-3
(P2 Mem23
VRD Hot)
Processor 3
Memory
VRD Hot
0-1
(P3 Mem01
VRD Hot)
Processor 3
Memory
VRD Hot
2-3
(P4 Mem23
VRD Hot)
Processor 4
Memory
VRD Hot
0-1
(P4 Mem01
VRD Hot)
Revision 1.4
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
96h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
97h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
99h
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
9Ah
All
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
98h
209
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Processor 4
Memory
VRD Hot
2-3
(P4 Mem23
VRD Hot)
Power Supply
1 Fan
Tachomet
er 1
(PS1 Fan
Tach 1)
Power Supply
1 Fan
Tachomet
er 2
(PS1 Fan
Tach 2)
Power Supply
2 Fan
Tachomet
er 1
(PS2 Fan
Tach 1)
Power Supply
2 Fan
Tachomet
er 2
(PS2 Fan
Tach 2)
Processor 1
DIMM
Aggregat
e Thermal
Margin 1
(P1 DIMM
Thrm Mrgn1)
9Bh
All
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Temperat
ure
01h
Digital
Discrete
05h
01 - Limit
exceeded
Non-fatal
As and De
–
Trig Offset
A
–
A0h
Chassisspecific
Fan
04h
Generic –
digital
discrete
01 – State
Asserted
Non-fatal
As and De
-
Trig Offset
M
-
A1h
Chassisspecific
Fan
04h
Generic –
digital
discrete
01 – State
Asserted
Non-fatal
As and De
-
Trig Offset
M
-
A4h
Chassisspecific
Fan
04h
Generic –
digital
discrete
01 – State
Asserted
Non-fatal
As and De
-
Trig Offset
M
-
A5h
Chassisspecific
Fan
04h
Generic –
digital
discrete
01 – State
Asserted
Non-fatal
As and De
-
Trig Offset
M
-
As and De
Analog
R, T
A
–
nc = Degraded
c = Non-fatal
B0h
210
All
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Processor 1
DIMM
Aggregat
e Thermal
Margin 2
(P1 DIMM
Thrm Mrgn2)
Processor 2
DIMM
Aggregat
e Thermal
Margin 1
(P2 DIMM
Thrm Mrgn1)
Processor 2
DIMM
Aggregat
e Thermal
Margin 2
(P2 DIMM
Thrm Mrgn2)
Processor 3
DIMM
Aggregat
e Thermal
Margin 1
(P3 DIMM
Thrm Mrgn1)
Revision 1.4
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
As and De
Analog
R, T
A
–
As and De
Analog
R, T
A
–
As and De
Analog
R, T
A
–
As and De
Analog
R, T
A
–
Rearm
Stand
-by
nc = Degraded
c = Non-fatal
B1h
All
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
B2h
All
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
B3h
All
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
B4h
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
211
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Processor 3
DIMM
Aggregat
e Thermal
Margin 2
(P3 DIMM
Thrm Mrgn2)
Processor 4
DIMM
Aggregat
e Thermal
Margin 1
(P4 DIMM
Thrm Mrgn1)
Processor 4
DIMM
Aggregat
e Thermal
Margin 2
(P4 DIMM
Thrm Mrgn2)
Fan
Tachomet
er
Sensors
(Chassis
specific
sensor
names)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
Rearm
De-assert
Value/
Offsets
Data
As and De
Analog
R, T
A
–
As and De
Analog
R, T
A
–
As and De
Analog
R, T
A
–
As and De
Analog
R, T
M
-
Stand
-by
nc = Degraded
c = Non-fatal
B5h
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
B6h
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
nc = Degraded
c = Non-fatal
B7h
BAh–
BFh
212
Platform
Specific
Temperat
ure
01h
Threshold
01h
[u] [c,nc]
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc = Degraded
2
c = Non-fatal
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Platform
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
Event/
Event Offset
Triggers
Contrib. To
System Status
Sensor
#
Applicability
C0h
All
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtempe
rature
Fatal
As and De
–
Trig Offset
M
-
C1h
All
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtempe
rature
Fatal
As and De
–
Trig Offset
M
-
C2h
All
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtempe
rature
Fatal
As and De
–
Trig Offset
M
X
C3h
All
Memory
0Ch
Sensor
Specific
6Fh
0A- Critical
overtempe
rature
Fatal
As and De
–
Trig Offset
M
X
(Sensor name
in SDR)
Processor 1
DIMM
Thermal Trip
(P1 Mem
Thrm Trip)
Processor 2
DIMM
Thermal Trip
(P2 Mem
Thrm Trip)
Reading
Type
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Processor 3
DIMM
Thermal Trip
(P3 Mem
Thrm Trip)
Processor 4
DIMM
Thermal Trip
(P4 Mem
Thrm Trip)
Revision 1.4
213
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Platform
Intel® Server Board S1600JP TPS
Sensor
Type
Global
Aggregat
e
Temperat
ure
Margin 2
(Agg Therm
Mrgn 2)
Global
Aggregat
e
Temperat
ure
Margin 3
(Agg Therm
Mrgn 3)
Global
Aggregat
e
Temperat
ure
Margin 4
(Agg Therm
Mrgn 4)
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Applicability
C8h
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
C9h
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
CAh
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
CBh
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
(Sensor name
in SDR)
Global
Aggregat
e
Temperat
ure
Margin 1
(Agg Therm
Mrgn 1)
Event/
Sensor
#
214
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Revision 1.4
Stand
-by
Intel® Server Board S1600JP TPS
Full Sensor
Name
Platform
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
Global
Aggregat
e
Temperat
ure
Margin 6
(Agg Therm
Mrgn 6)
Global
Aggregat
e
Temperat
ure
Margin 7
(Agg Therm
Mrgn 7)
Global
Aggregat
e
Temperat
ure
Margin 8
(Agg Therm
Mrgn 8)
Revision 1.4
Event Offset
Triggers
Contrib. To
System Status
Applicability
CCh
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
CDh
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
CEh
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
CFh
Platform
Specific
Temperat
ure
01h
Threshold
01h
-
-
-
Analog
R, T
A
–
(Sensor name
in SDR)
Global
Aggregat
e
Temperat
ure
Margin 5
(Agg Therm
Mrgn 5)
Event/
Sensor
#
Reading
Type
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
215
Rearm
Stand
-by
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Baseboard
+12V
(BB +12.0V)
Baseboard
+5V
(BB +5.0V)
Baseboard
+3.3V
(BB +3.3V)
Baseboard
+5V
Stand-by
(BB +5.0V
STBY)
Event/
Reading
Type
Event Offset
Triggers
Readable
Event
Rearm
De-assert
Value/
Offsets
Data
As and De
Analog
R, T
A
–
Stand
-by
D0h
All
D1h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
D2h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
As and De
Analog
R, T
A
X
As and De
Analog
R, T
A
X
All
Voltage
02h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
Assert/
Voltage
02h
D3h
Threshold
01h
Contrib. To
System Status
Threshold
01h
nc = Degraded
c = Non-fatal
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
Baseboard
+3.3V
Auxiliary
(BB +3.3V
AUX)
D4h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
Baseboard
+1.05V
Processor
1 Vccp
(BB
+1.05Vccp
P1)
D6h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.05V
Processor
2 Vccp
(BB
+1.05Vccp
P2)
D7h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
216
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Baseboard
+1.5V P1
Memory
AB VDDQ
(BB +1.5
P1MEM AB)
D8h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.5V P1
Memory
CD
VDDQ
(BB +1.5
P1MEM CD)
D9h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.5V P2
Memory
AB VDDQ
(BB +1.5
P2MEM AB)
DAh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.5V P2
Memory
CD
VDDQ
(BB +1.5
P2MEM CD)
DBh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.8V
Aux
(BB +1.8V
AUX)
DCh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Revision 1.4
217
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Baseboard
+1.1V
Stand-by
(BB +1.1V
STBY)
DDh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
CMOS
Battery
(BB +3.3V
Vbat)
DEh
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.35V
P1 Low
Voltage
Memory
AB VDDQ
(BB +1.35
P1LV AB)
E4h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.35V
P1 Low
Voltage
Memory
CD
VDDQ
(BB +1.35
P1LV CD)
E5h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.35V
P2 Low
Voltage
Memory
AB VDDQ
(BB +1.35
P2LV AB)
E6h
All
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
218
Revision 1.4
Intel® Server Board S1600JP TPS
Full Sensor
Name
Sensor
#
Platform
Applicability
Appendix B: Integration BMC Sensor
Tables
Sensor
Type
(Sensor name
in SDR)
Baseboard
+1.35V
P2 Low
Voltage
Memory
CD
VDDQ
(BB +1.35
P2LV CD)
E7h
Baseboard
+3.3V
Riser 1
Power
Good
(BB +3.3
RSR1 PGD)
EAh
Baseboard
+3.3V
Riser 2
Power
Good
(BB +3.3
RSR2 PGD)
Event/
Reading
Type
Event Offset
Triggers
Contrib. To
System Status
Assert/
Readable
Event
De-assert
Value/
Offsets
Data
Rearm
Stand
-by
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
EBh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+0.9V
(BB 0.9V Core
IB)
ECh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.8V
(BB 1.8V IB
I/O)
EDh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Baseboard
+1.1V
(BB 1.1V
PCH)
EEh
Platform
Specific
Voltage
02h
Threshold
01h
[u,l] [c,nc]
nc = Degraded
c = Non-fatal
As and De
Analog
R, T
A
–
Revision 1.4
All
219
Appendix B: Integration BMC Sensor Tables
Full Sensor
Name
Sensor
#
Platform
Applicability
Intel® Server Board S1600JP TPS
Sensor
Type
(Sensor name
in SDR)
Baseboard
+1.2V
(BB +1.2V IB)
Hard Disk
Drive 0 14 Status
(HDD 0 - 14
Status)
Notes:
1.
2.
3.
EFh
Platform
Specific
Voltage
02h
Event/
Reading
Type
Threshold
01h
Event Offset
Triggers
[u,l] [c,nc]
00 - Drive
Presence
F0h
FEh
Chassisspecific
Drive Slot
0Dh
Sensor
Specific
6Fh
01- Drive Fault
07 Rebuild/Re
map in
progress
Contrib. To
System Status
nc = Degraded
c = Non-fatal
Assert/
Readable
Event
Rearm
De-assert
Value/
Offsets
Data
As and De
Analog
R, T
A
–
As and De
–
Trig Offset
A
X
Stand
-by
OK
Degraded
Degraded
Redundancy sensors will be only present on systems with appropriate hardware to support redundancy (for instance, fan or power supply).
This is only applicable when the system does not support redundant Power supplies. When redundancy is supported, then the contribution to system
state is driven by the power unit redundancy sensor.
This is only applicable when the system does not support redundant fans. When fan redundancy is supported, then the contribution to system state is
driven by the fan redundancy sensor.
220
Revision 1.4
Intel® Server Board S1600JP TPS
Appendix C: BIOS Sensors and SEL Data
Appendix C: BIOS Sensors and SEL Data
BIOS owns a set of IPMI-compliant Sensors. These are actually divided in ownership between
BIOS POST (GID = 01) and BIOS SMI Handler (GID = 33). The SMI Handler Sensors are
typically for logging runtime error events, but they are active during POST and may log errors
such as Correctable Memory ECC Errors if they occur.
It is important to remember that a Sensor is uniquely identified by the combination of Sensor
Owner plus Sensor Number. There are cases where the same Sensor Number is used with
different Sensor Owners – this is not a conflict. For example, in the BIOS Sensors list there is a
Sensor Number 83h for Sensor Owner 01h (BIOS POST) as well as for Sensor Owner 33h (SMI
Handler), but these are two distinct sensors reporting the same type of event from different
sources (Generator IDs 01h and 33h).
On the other hand, each distinct Sensor (GID + Sensor Number) is defined by one specific
Sensor Type describing the kind of data being reported, and one specific Event Type describing
the type of event and the format of the data being reported.
Table 107. BIOS Sensor and SEL Data
Sensor Name
Mirroring
Redundancy State
Sensor
Number
01h
Sensor
Owner
(GID)
33h (SMI
Handler)
Sensor Type
0Ch
(Memory)
Event/Reading Type
Event Data 2
Offset Values
Event Data 3
0Bh (Discrete,
Redundancy State)
0h = Fully Redundant
2h = Redundancy
Degraded
ED2 =[7:4] =
Mirroring
Domain
0-1 =
Channel Pair
for Socket
[3:2] =
Reserved
[1:0] = Rank
on DIMM
0-3 = Rank
Number
ED3 =
[7:5]= Socket ID
0-3 = CPU1-4
[4:3] = Channel
0-3 = Channel AD for Socket
[2:0] = DIMM
0-2 = DIMM 1-3
on Channel
Revision 1.4
221
Appendix C: BIOS Sensors and SEL Data
Sensor Name
Memory RAS
Configuration
Status
Sensor
Number
02h
Sensor
Owner
(GID)
01h (BIOS
POST)
Intel® Server Board S1600JP TPS
Sensor Type
0Ch
(Memory)
Event/Reading Type
Event Data 2
Offset Values
Event Data 3
09h (Digital Discrete)
0h = RAS Configuration
Disabled
1h = RAS Configuration
Enabled
ED2 =
[7:4] =
Reserved
[3:0] Config
Err
0 = None
3 = Invalid
DIMM Config
for RAS Mode
ED3 =
[7:4] = Reserved
[3:0] = RAS Mode
0 = None
1 = Mirroring
2 = Lockstep
4 = Rank Sparing
Memory ECC
Error
02h
33h (SMI
Handler)
0Ch
(Memory)
6Fh (Sensor Specific
Offset)
0h = Correctable Error
1h = Uncorrectable
Error
ED2 =
[7:2] =
Reserved
[1:0] = Rank
on DIMM
0-3 = Rank
Number
ED3 =
[7:5]= Socket ID
0-3 = CPU1-4
[4:3] = Channel
0-3 = Channel AD for Socket
[2:0] = DIMM
0-2 = DIMM 1-3
on Channel
Legacy PCI Error
03h
33h (SMI
Handler)
13h (Critical
Interrupt)
6Fh (Sensor Specific
Offset)
4h = PCI PERR
5h = PCI SERR
222
ED2 =
[7:0] = Bus
Number
ED3 =
[7:3] = Device
Number
[2:0] = Function
Number
Revision
1.4
Intel® Server Board S1600JP TPS
Sensor Name
Sensor
Number
PCIe Fatal Error
(Standard AER
Errors)
(see Sensor 14h
for continuation)
04h
PCIe Correctable
Error
(Standard AER
Errors)
05h
BIOS POST Error
06h
Revision 1.4
Appendix C: BIOS Sensors and SEL Data
Sensor
Owner
(GID)
33h (SMI
Handler)
33h (SMI
Handler)
01h (BIOS
POST)
Sensor Type
13h (Critical
Interrupt)
13h (Critical
Interrupt)
0Fh (System
Firmware
Progress)
Event/Reading Type
Event Data 2
Offset Values
Event Data 3
70h (OEM Discrete)
0h = Data Link Layer
Protocol Error
1h = Surprise Link Down
Error
2h = Completer Abort
3h = Unsupported
Request
4h = Poisoned TLP
5h = Flow Control
Protocol
6h = Completion Timeout
7h = Receiver Buffer
Overflow
8h = ACS Violation
9h = Malformed TLP
Ah = ECRC Error
Bh = Received Fatal
Message From
Downstream
Ch = Unexpected
Completion
Dh = Received
ERR_NONFATAL
Message
Eh = Uncorrectable
Internal
Fh = MC Blocked TLP
71h (OEM Discrete)
0h = Receiver Error
1h = Bad DLLP
2h = Bad TLP
3h = Replay Num
Rollover
4h = Replay Timer
timeout
5h = Advisory Nonfatal
6h = Link BW
Changed
7h = Correctable
Internal
8h = Header Log
Overflow
6Fh (Sensor Specific
Offset)
0h = System Firmware
Error (POST Error
Code)
ED2 =
[7:0] = Bus
Number
ED3 =
[7:3] = Device
Number
[2:0] = Function
Number
ED2 =
[7:0] = Bus
Number
ED3 =
[7:3] = Device
Number
[2:0] = Function
Number
ED2 =
[7:0] = LSB of
POST Error
Code
ED3 =
[7:0] MSB of POST
Error Code
223
Appendix C: BIOS Sensors and SEL Data
Sensor Name
Sensor
Number
QPI Correctable
Errors
(reserved for
Validation)
06h
QPI Fatal Error
(see Sensor 17h
for continuation)
07h
Sensor
Owner
(GID)
Intel® Server Board S1600JP TPS
Sensor Type
33h (SMI
Handler)
13h (Critical
Interrupt)
33h (SMI
Handler)
13h (Critical
Interrupt)
Event/Reading Type
Event Data 2
Offset Values
Event Data 3
72h (OEM Discrete)
Offset Reserved
ED2 =
[7:0] = Node
ID
0-3 = CPU1-4
ED3 = Reserved
Chipset
Proprietary
(reserved for
Validation)
08h
QPI Link Width
Reduced
09h
33h (SMI
Handler)
19h (Chipset)
01h (BIOS
POST)
13h (Critical
Interrupt)
73h (OEM Discrete)
0h = Link Layer
Uncorrectable ECC Error
1h = Protocol Layer
Poisoned Packet
Reception Error
2h = Link/PHY Init
Failure with resultant
degradation in link width
3h = PHY Layer detected
drift buffer alarm
4h = PHY detected
latency buffer rollover
5h = PHY Init Failure
6h = Link Layer generic
control error (buffer
overflow/underflow,
credit underflow and so
on.)
7h = Parity error in link or
PHY layer
8h = Protocol layer
timeout detected
9h = Protocol layer failed
response
Ah = Protocol layer
illegal packet field, target
Node ID Error, and so
on.
Bh = Protocol Layer
Queue/table
overflow/underflow
Ch = Viral Error
Dh = Protocol Layer
parity error
Eh = Routing Table Error
Fh = (unused)
ED2 =
[7:0] = Node
ID
0-3 = CPU1-4
ED3 = No Data
75h (OEM Discrete)
ED2 = Reserved
Offset Reserved
ED3 = Reserved
77h (OEM Discrete)
ED2 =
[7:0] = Node
ID
0-3 = CPU1-4
1h = Reduced to ½ width
2h = Reduced to ¼
width
ED3 = No Data
224
Revision
1.4
Intel® Server Board S1600JP TPS
Sensor Name
Sensor
Number
Memory Error
Extension
(reserved for
Validation)
10h
Sparing
Redundancy State
11h
Appendix C: BIOS Sensors and SEL Data
Sensor
Owner
(GID)
Sensor Type
33h (SMI
Handler)
0Ch
(Memory)
33h (SMI
Handler)
0Ch
(Memory)
Event/Reading Type
Event Data 2
Offset Values
Event Data 3
7Fh (OEM Discrete)
ED2 = Reserved
Offset Reserved
ED3 = Reserved
0Bh (Discrete,
Redundancy State)
ED2 =
[7:4] = Sparing
Domain
0-3 =
Channel A-D
for Socket
[3:2] =
Reserved
[1:0] = Rank
on DIMM
0-3 = Rank
Number
0h = Fully Redundant
2h = Redundancy
Degraded
ED3 =
[7:5]= Socket ID
0-3 = CPU1-4
[4:3] = Channel
0-3 = Channel AD for Socket
[2:0] = DIMM
0-2 = DIMM 1-3
on Channel
Memory RAS
Mode Select
12h
01h (BIOS
POST)
0Ch
(Memory)
09h (Digital Discrete)
0h = RAS Configuration
Disabled
1h = RAS
Configuration
Enabled
ED2 = Prior Mode
[7:4] =
Reserved
[3:0] = RAS
Mode
0 = None
1 = Mirroring
2 = Lockstep
4 = Rank
Sparing
ED3 = Selected
Mode
[7:4] = Reserved
[3:0] = RAS Mode
0 = None
1 = Mirroring
2 = Lockstep
4 = Rank Sparing
Revision 1.4
225
Appendix C: BIOS Sensors and SEL Data
Sensor Name
Memory Parity
Error
Sensor
Number
13h
Sensor
Owner
(GID)
33h (SMI
Handler)
Intel® Server Board S1600JP TPS
Sensor Type
0Ch
(Memory)
Event/Reading Type
Event Data 2
Offset Values
Event Data 3
6Fh (Sensor Specific
Offset)
2h = Address Parity Error
ED2 = Validity
[7:5] =
Reserved
[4] = Channel
Validity Check
0 = ED3
Chan # Not
Valid
1 = ED3
Chan # Is
Valid
[3] = DIMM
Validity Check
0 = ED3
DIMM # Not
Valid
1 = ED3
DIMM # Is
Valid
[2:0] = Error
Type
0 = Not
Known
2 = Address
Parity Error
ED3 = Location
[7:5]= Socket ID
0-3 = CPU1-4
[4:2] = Channel
0-3 = Channel AD for Socket
[1:0] = DIMM
0-2 = DIMM 1-3
on Channel
PCIe Fatal Error#2
(Standard AER
Errors)
(continuation of
Sensor 04h)
14h
33h (SMI
Handler)
13h (Critical
Interrupt)
226
76h (OEM Discrete)
0h = Atomic Egress
Blocked
1h = TLP Prefix Blocked
Fh = Unspecified NonAER Fatal Error
ED2 =
[7:0] = Bus
Number
ED3 =
[7:3] = Device
Number
[2:0] = Function
Number
Revision
1.4
Intel® Server Board S1600JP TPS
Sensor Name
QPI Fatal Error
(continuation of
Sensor 07h)
System Event
Sensor
Number
17h
83h
Appendix C: BIOS Sensors and SEL Data
Sensor
Owner
(GID)
33h (SMI
Handler)
01h (BIOS
POST)
Sensor Type
13h (Critical
Interrupt)
12h (System
Event)
Event/Reading Type
Event Data 2
Offset Values
Event Data 3
74h (OEM Discrete)
0h = Illegal inbound
request
1h = IIO Write
Cache
Uncorrectable Data
ECC Error
2h = IIO CSR
crossing 32-bit
boundary Error
3h = IIO Received
XPF physical/logical
redirect interrupt
inbound
4h = IIO Illegal SAD or
Illegal or non-existent
address or memory
5h = IIO Write Cache
Coherency Violation
6Fh (Sensor Specific
Offset)
1h = System Boot Event
5h = Time Synch (EPSD)
ED2 =
[7:0] = Node
ID
0-3 = CPU1-4
ED3 = No Data
ED2 = (only for
Time Synch)
[7:0] Synch #
00h = 1st in
pair
80h = 2nd in
pair
ED3 = No Data
System Event
83h
33h (SMI
Handler)
12h (System
Event)
6Fh (Sensor Specific
Offset)
5h = Time Synch (EPSD)
ED2 = (only for
Time Synch)
[7:0] Synch #
00h = 1st in
pair
80h = 2nd in
pair
ED3 = No Data
Revision 1.4
227
Appendix D: POST Code LED Decoder
Intel® Server Board S1600JP TPS
Appendix D: POST Code LED Decoder
During the system boot process, the BIOS executes several platform configuration processes,
each of which is assigned a specific hex POST code number. As each configuration routine is
started, the BIOS displays the POST code on the POST code diagnostic LEDs found on the
back edge of the server board. To assist in troubleshooting a system hang during the POST
process, the diagnostic LEDs can be used to identify the last denote POST process to be
executed.
Each POST code is represented by the eight amber diagnostic LEDs. The POST codes are
divided into two nibbles, an upper nibble and a lower nibble. The upper nibble bits are
represented by diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented by
diagnostics LEDs #0, #1, #2, and #3. If the bit is set in the upper and lower nibbles, then the
corresponding LED is lit. If the bit is clear, then the corresponding LED is off.
The diagnostic LED #7 is labeled as “MSB” (Most Significant Bit), and the diagnostic LED #0 is
labeled as “LSB” (Least Significant Bit).
Figure 57. Diagnostic LED Placement Diagram
In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The
LEDs are decoded as follows:
Table 108. POST Progress Code LED Example
Upper Nibble LEDs
LEDs
Lower Nibble LEDs
MSB
LSB
LED #7
LED #6
LED #5
LED #4
LED #3
LED #2
LED #1
LED #0
8h
4h
2h
1h
8h
4h
2h
1h
Status
ON
OFF
ON
OFF
ON
ON
OFF
OFF
Results
1
Ah
0
1
0
1
Ch
1
0
0
Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated
as ACh.
228
Revision
1.4
Intel® Server Board S1600JP TPS
Appendix D: POST Code LED Decoder
Table 109. Diagnostic LED POST Code Decoder
Diagnostic LED Decoder
= On, 0=Off
Checkpoint
Upper Nibble
Lower Nibble
Description
MSB
LED
LSB
8h
4h
2h
1h
8h
4h
2h
1h
#7
#6
#5
#4
#3
#2
#1
#0
Host Processor
0x10h
0
0
0
1
0
0
0
0
0x11h
0x12h
0x13h
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
0
0
0
0
1
1
1
0
1
Power-on initialization of the host processor
(bootstrap processor)
Host processor cache initialization (including AP)
Starting application processor initialization
SMM initialization
0x21h
0
0
1
0
0
0
0
1
Initializing a chipset component
0x22h
0x23h
0x24h
0x25h
0x26h
0x27h
0x28h
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
0
1
1
1
1
0
1
1
0
0
1
1
0
0
1
0
1
0
1
0
0xE4h
1
1
1
0
0
1
0
0xE6h
0xE8h
0xE9h
0xEAh
0xEBh
0xECh
0xEDh
0xEBh
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
0
1
0
0
1
1
0
0
1
0xA0h
0xA1h
0xA2h
0xA3h
0xA4h
0xA5h
0xA6h
0xA7h
0xA8h
0xA9h
0xAAh
0xABh
0xACh
0xADh
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
Chipset
Memory
Revision 1.4
Reading configuration data from memory (SPD on FBDIMM)
Detecting presence of memory
Programming timing parameters in the memory controller
Configuring memory parameters in the memory controller
Optimizing memory controller settings
Initializing memory, such as ECC in it
Testing memory
BIOS cannot communicate with DIMM (serial channel
0
hardware failure)
0
DIMM(s) failed Memory iBIST or Memory Link Training failure
0
No memory available (system halted)
1
Unsupported or invalid DIMM configuration (system halted)
0
DIMM training sequence failed (system halted)
1
Memory test failed (system halted)
0
Unsupported or invalid DIMM configuration (system halted)
1
Unsupported or invalid DIMM configuration (system halted)
1
DIMM with corrupted SPD data detected (system halted)
QuickPath Interconnect (QPI)
0
QPI Initialization
1
QPI Initialization
0
QPI Initialization
1
QPI Initialization
0
QPI Initialization
1
QPI Initialization
0
QPI Initialization
1
QPI Initialization
0
QPI Initialization
1
QPI Initialization
0
QPI Initialization
1
QPI Initialization
0
QPI Initialization
1
QPI Initialization
229
Appendix D: POST Code LED Decoder
Intel® Server Board S1600JP TPS
Diagnostic LED Decoder
= On, 0=Off
Checkpoint
Upper Nibble
Lower Nibble
Description
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
#7
#6
#5
#4
#3
#2
#1
#0
0xAEh
0xAFh
1
1
0
0
1
1
0
0
1
1
1
1
0xB0h
0xB1h
0xB2h
0xB3h
0xB4h
0xB5h
0xB6h
0xB7h
0xB8h
0xB9h
0xBAh
0xBBh
0xBCh
0xBDh
0xBEh
0xBFh
PCI Bus
0x50h
0x51h
0x52h
0x53h
0x54h
0x55h
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
1
0
QPI Initialization
1
1
QPI Initialization
Integrated Memory Controller (IMC)
0
0
Memory Initialization of Integrated Memory Controller
0
1
Memory Initialization of Integrated Memory Controller
1
0
Memory Initialization of Integrated Memory Controller
1
1
Memory Initialization of Integrated Memory Controller
0
0
Memory Initialization of Integrated Memory Controller
0
1
Memory Initialization of Integrated Memory Controller
1
0
Memory Initialization of Integrated Memory Controller
1
1
Memory Initialization of Integrated Memory Controller
0
0
Memory Initialization of Integrated Memory Controller
0
1
Memory Initialization of Integrated Memory Controller
1
0
Memory Initialization of Integrated Memory Controller
1
1
Memory Initialization of Integrated Memory Controller
0
0
Memory Initialization of Integrated Memory Controller
0
1
Memory Initialization of Integrated Memory Controller
1
0
Memory Initialization of Integrated Memory Controller
1
1
Memory Initialization of Integrated Memory Controller
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
0
0
LED
0
1
0
1
0
1
Enumerating PCI buses
Allocating resources to PCI buses
Hot Plug PCI controller initialization
Reserved for PCI bus
Reserved for PCI bus
Reserved for PCI bus
QuickPath Interconnect (QPI)
0xA0h
0xA1h
0xA2h
0xA3h
0xA4h
0xA5h
0xA6h
0xA7h
0xA8h
0xA9h
0xAAh
0xABh
0xACh
0xADh
0xAEh
0xAFh
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
QPI Initialization
Integrated Memory Controller (IMC)
230
Revision
1.4
Intel® Server Board S1600JP TPS
Appendix D: POST Code LED Decoder
Diagnostic LED Decoder
= On, 0=Off
Checkpoint
Upper Nibble
Lower Nibble
Description
MSB
LED
0xB0h
0xB1h
0xB2h
0xB3h
0xB4h
0xB5h
0xB6h
0xB7h
0xB8h
0xB9h
0xBAh
0xBBh
0xBCh
0xBDh
0xBEh
0xBFh
LSB
8h
4h
2h
1h
8h
4h
2h
1h
#7
#6
#5
#4
#3
#2
#1
#0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
Memory Initialization of Integrated Memory Controller
PCI Bus
0x50h
0x51h
0x52h
0x53h
0x54h
0x55h
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
0
0
0
1
0
1
0
1
0x56h
0x57h
0x58h
0x59h
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
0
0
1
1
1
1
0
0
1
1
0
0
0
1
0
1
0x5Ah
0x5Bh
0x5Ch
0x5Dh
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
1
1
1
1
0
0
1
1
1
1
0
0
0
1
0
1
0x5Eh
0x5Fh
0
0
1
1
0
0
1
1
1
1
1
1
1
1
0
1
0x61h
0
1
1
0
0
0
0
1
0x63h
0
1
1
0
0
0
1
1
0x70h
0x71h
0x72h
0
0
0
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
1
0
1
0
Enumerating PCI buses
Allocating resources to PCI buses
Hot Plug PCI controller initialization
Reserved for PCI bus
Reserved for PCI bus
Reserved for PCI bus
USB
Initializing USB host controllers
Detecting USB devices
Resetting USB bus
Reserved for USB devices
ATA/ATAPI/SATA
Resetting SATA bus and all devices
Detecting the presence of ATA device
Enable SMART if supported by ATA device
Reserved for ATA
SMBUS*
Resetting SMBUS*
Reserved for SMBUS*
I/O Controller Hub
Initializing I/O Controller Hub
uper I/O
Revision 1.4
Initializing Super I/O
Local Console
Resetting the video controller (VGA)
Disabling the video controller (VGA)
Enabling the video controller (VGA)
231
Appendix D: POST Code LED Decoder
Intel® Server Board S1600JP TPS
Diagnostic LED Decoder
= On, 0=Off
Checkpoint
Upper Nibble
Lower Nibble
Description
MSB
LSB
8h
4h
2h
1h
8h
4h
2h
1h
#7
#6
#5
#4
#3
#2
#1
#0
0x73h
0
1
1
1
0
0
1
0x78h
0x79h
0x7Ah
0x7Bh
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
1
1
0x90h
0x91h
0x92h
0x93h
0x94h
0x96h
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
0
0
1
1
0
1
0x98h
0x99h
0x9Ah
0x9Bh
0x9Ch
1
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
0
0
0
0
0
0
0
1
1
0
1
1
1
1
1
0xA8h
0xA9h
0xAAh
0xABh
0xACh
0xADh
1
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
0
0
1
1
1
1
1
1
0
0
0
0
1
1
0
0
1
1
0
0
0xB0h
0xB1h
1
1
0
0
1
1
1
1
0
0
0
0
0
0
0xB2h
1
0
1
1
0
0
1
0xB3h
0xB4h
1
1
0
0
1
1
1
1
0
0
0
1
1
0
0xB8h
0xB9h
1
1
0
0
1
1
1
1
1
1
0
0
0
0
0xBAh
1
0
1
1
1
0
1
0xBCh
0xBDh
1
1
0
0
1
1
1
1
1
1
1
1
0
0
0xD0
0xD1
0xD2
0xD3
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
0
0
0
0
0
0
0
1
1
LED
1
Reserved for video controller (VGA)
Remote Console
0
Resetting the console controller
1
Disabling the console controller
0
Enabling the console controller
1
Reserved for console controller
Keyboard (only USB)
0
Resetting the keyboard
1
Disabling the keyboard
0
Detecting the presence of the keyboard
1
Enabling the keyboard
0
Clearing keyboard input buffer
0
Reserved for keyboard
Mouse (only USB)
0
Resetting the mouse
1
Detecting the mouse
0
Detecting the presence of mouse
1
Enabling the mouse
0
Reserved for mouse
Serial Port
0
Resetting the serial port
1
Disabling the serial port
0
Detecting the presence of the serial port
1
Clearing serial port buffer
0
Enabling serial port
1
Reserved for serial port
Fixed Media
0
Resetting fixed media device
1
Disabling fixed media device
Detecting presence of a fixed media device (SATA hard drive
0
detection, and so forth)
1
Enabling/configuring a fixed media device
0
Reserved for fixed media
Removable Media
0
Resetting removable media device
1
Disabling removable media device
Detecting presence of a removable media device (SATA
0
CDROM detection, and so forth)
0
Enabling/configuring a removable media device
1
Reserved for removable media device
Boot Device Selection (BDS)
0
Entered the Boot Device Selection phase (BDS)
1
Return to last good boot device
0
Setup boot device selection policy
1
Connect boot device controller
232
Revision
1.4
Intel® Server Board S1600JP TPS
Appendix D: POST Code LED Decoder
Diagnostic LED Decoder
= On, 0=Off
Checkpoint
Upper Nibble
Lower Nibble
MSB
Description
LSB
8h
4h
2h
1h
8h
4h
2h
1h
#7
#6
#5
#4
#3
#2
#1
#0
0xD4
0xD5
0xD6
0xDF
1
1
1
1
1
1
1
1
0
0
0
0
1
1
1
1
0
0
0
1
1
1
1
1
0
0
1
1
0xE0h
0xE1h
0xE2h
0xE3h
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0xF0h
0xF1h
0xF2h
0xF3h
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0xE4h
0xE5h
0xE6h
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0xE7h
0xE8h
0xE9h
0xEAh
0xEBh
0xECh
0xEDh
0xEEh
0xEFh
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
0x30h
0x31h
0x34h
0x35h
0x36h
0x3Eh
0
0
0
0
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
1
0x3Fh
0
0
1
1
1
LED
Revision 1.4
0
Attempt flash update boot mode
1
Transfer control to EFI boot
0
Trying to boot device selection
1
Reserved for boot device selection
Pre-EFI Initialization (PEI) Core
0
0
0
Entered Pre-EFI Initialization phase (PEI)
0
0
1
Started dispatching early initialization modules (PEIM)
0
1
0
Initial memory found, configured, and installed correctly
0
1
1
Transfer control to the DXE Core
PEI Modules
0
0
0
Install PEIM for Platform Status Codes
0
0
1
Detecting Platform Type
0
1
0
Early Platform Initialization
0
1
1
PEI Modules initialized
Driver eXecution Environment (DXE) Core
1
0
0
Entered EFI driver execution phase (DXE)
1
0
1
Started dispatching drivers
1
1
0
Started connecting drivers
DXE Drivers
1
0
1
Waiting for user input
0
0
0
Checking password
0
0
1
Entering BIOS setup
1
0
0
Flash Update
1
0
1
Legacy Option ROM initialization
0
0
0
DXE Drivers initialized
0
0
1
Transfer control to Boot Device Selection (BDS)
1
0
0
Calling Int 19. One beep unless silent boot is enabled.
1
0
1
Unrecoverable boot failure
Pre-EFI Initialization Module (PEIM)/Recovery
0
0
0
Crisis recovery initiated because of a user request
0
0
1
Crisis recovery initiated by software (corrupt flash)
1
0
0
Loading crisis recovery capsule
1
0
1
Handing off control to the crisis recovery capsule
1
1
0
Begin crisis recovery
1
1
0
No crisis recovery capsule detected
Crisis recovery capsule failed integrity check of capsule
1
1
1
descriptors
233
Appendix E: Video POST Code Errors
Intel® Server Board S1600JP TPS
Appendix E: Video POST Code Errors
Whenever possible, the BIOS outputs the current boot progress codes on the video screen.
Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class,
subclass, and operation information. The class and subclass fields point to the type of hardware
being initialized. The operation field represents the specific initialization activity. Based on the
data bit availability to display progress codes, a progress code can be customized to fit the data
width. The higher the data bit, the higher the granularity of information that can be sent on the
progress port. The progress codes may be reported by the system BIOS or option ROMs.
The Response section in the following table is divided into three types:



No Pause: The message is displayed on the local Video screen during POST or in the
Error Manager. The system continues booting with a degraded state. The user may want
to replace the erroneous unit. The setup POST error Pause setting does not have any
effect with this error.
Pause: The message is displayed on the Error Manager screen, and an error is logged
to the SEL. The setup POST error Pause setting determines whether the system pauses
to the Error Manager for this type of error, where the user can take immediate corrective
action or choose to continue booting.
Halt: The message is displayed on the Error Manager screen, an error is logged to the
SEL, and the system cannot boot unless the error is resolved. The user needs to replace
the faulty part and restart the system. The setup POST error Pause setting does not
have any effect with this error.
Table 110. POST Error Messages and Handling
Error Code
Error Message
Response
0012
CMOS date/time not set.
Major
0048
Password check failed.
Major
0108
Keyboard component encountered a locked error.
Minor
0109
Keyboard component encountered a stuck key error.
Minor
0113
Fixed Media The SAS RAID firmware cannot run properly. The user should attempt to reflash
the firmware.
Major
0140
PCI component encountered a PERR error.
Major
0141
PCI resource conflict.
Major
0146
PCI out of resources error.
Major
0192
Processor 0x cache size mismatch detected.
Fatal
0193
Processor 0x stepping mismatch.
Minor
0194
Processor 0x family mismatch detected.
Fatal
0195
Processor 0x Intel(R) QPI speed mismatch.
Major
0196
Processor 0x model mismatch.
Fatal
0197
Processor 0x speeds mismatched.
Fatal
0198
Processor 0x family is not supported.
Fatal
019F
Processor and chipset stepping configuration is unsupported.
Major
5220
CMOS/NVRAM Configuration Cleared.
Major
5221
Passwords cleared by jumper.
Major
234
Revision
1.4
Intel® Server Board S1600JP TPS
Error Code
Appendix E: Video POST Code Errors
Error Message
Response
5224
Password clear Jumper is Set.
Major
8160
Processor unable to apply microcode update.
Major
8180
Processor microcode update not found.
Minor
8190
Watchdog timer failed on last boot.
Major
8198
OS boot watchdog timer failure.
Major
8300
Baseboard management controller failed self-test.
Major
84F2
Baseboard management controller failed to respond.
Major
84F3
Baseboard management controller in update mode.
Major
84F4
Sensor data record empty.
Major
84FF
System event log full.
Minor
8500
Memory component could not be configured in the selected RAS mode.
Major
8501
DIMM Population Error.
Major
8502
CLTT Configuration Failure Error.
Major
8520
DIMM_A1 failed Self-Test (BIST).
Major
8521
DIMM_A2 failed Self-Test (BIST).
Major
8522
DIMM_B1 failed Self-Test (BIST).
Major
8523
DIMM_B2 failed Self-Test (BIST).
Major
8524
DIMM_C1 failed Self-Test (BIST).
Major
8525
DIMM_C2 failed Self-Test (BIST).
Major
8526
DIMM_D1 failed Self-Test (BIST).
Major
8527
DIMM_D2 failed Self-Test (BIST).
Major
8540
DIMM_A1 Disabled.
Major
8541
DIMM_A2 Disabled.
Major
8542
DIMM_B1 Disabled.
Major
8543
DIMM_B2 Disabled.
Major
8544
DIMM_C1 Disabled.
Major
8545
DIMM_C2 Disabled.
Major
8546
DIMM_D1 Disabled.
Major
8547
DIMM_D2 Disabled.
Major
8560
DIMM_A1 Component encountered a Serial Presence Detection (SPD) fail error.
Major
8561
DIMM_A2 Component encountered a Serial Presence Detection (SPD) fail error.
Major
8562
DIMM_B1 Component encountered a Serial Presence Detection (SPD) fail error.
Major
8563
DIMM_B2 Component encountered a Serial Presence Detection (SPD) fail error.
Major
8564
DIMM_C1 Component encountered a Serial Presence Detection (SPD) fail error.
Major
8565
DIMM_C2 Component encountered a Serial Presence Detection (SPD) fail error.
Major
8566
DIMM_D1 Component encountered a Serial Presence Detection (SPD) fail error.
Major
8567
DIMM_D2 Component encountered a Serial Presence Detection (SPD) fail error.
Major
85A0
DIMM_A1 Uncorrectable ECC error encountered.
Major
85A1
DIMM_A2 Uncorrectable ECC error encountered.
Major
85A2
DIMM_B1 Uncorrectable ECC error encountered.
Major
85A3
DIMM_B2 Uncorrectable ECC error encountered.
Major
85A4
DIMM_C1 Uncorrectable ECC error encountered.
Major
85A5
DIMM_C2 Uncorrectable ECC error encountered.
Major
85A6
DIMM_D1 Uncorrectable ECC error encountered.
Major
Revision 1.4
235
Appendix E: Video POST Code Errors
Error Code
Intel® Server Board S1600JP TPS
Error Message
Response
85A7
DIMM_D2 Uncorrectable ECC error encountered.
Major
8604
Chipset Reclaim of non-critical variables complete.
Minor
9000
Unspecified processor component has encountered a nonspecific error.
Major
9223
Keyboard component was not detected.
Minor
9226
Keyboard component encountered a controller error.
Minor
9243
Mouse component was not detected.
Minor
9246
Mouse component encountered a controller error.
Minor
9266
Local Console component encountered a controller error.
Minor
9268
Local Console component encountered an output error.
Minor
9269
Local Console component encountered a resource conflict error.
Minor
9286
Remote Console component encountered a controller error.
Minor
9287
Remote Console component encountered an input error.
Minor
9288
Remote Console component encountered an output error.
Minor
92A3
Serial port component was not detected.
Major
92A9
Serial port component encountered a resource conflict error.
Major
92C6
Serial Port controller error.
Minor
92C7
Serial Port component encountered an input error.
Minor
92C8
Serial Port component encountered an output error.
Minor
94C6
LPC component encountered a controller error.
Minor
94C9
LPC component encountered a resource conflict error.
Major
9506
ATA/ATPI component encountered a controller error.
Minor
95A6
PCI component encountered a controller error.
Minor
95A7
PCI component encountered a read error.
Minor
95A8
PCI component encountered a write error.
Minor
9609
Unspecified software component encountered a start error.
Minor
9641
PEI Core component encountered a load error.
Minor
9667
PEI module component encountered an illegal software state error.
Fatal
9687
DXE core component encountered an illegal software state error.
Fatal
96A7
DXE boot services driver component encountered an illegal software state error.
Fatal
96AB
DXE boot services driver component encountered invalid configuration.
Minor
96E7
SMM driver component encountered an illegal software state error.
Fatal
0xA000
TPM device not detected.
Minor
0xA001
TPM device missing or not responding.
Minor
0xA002
TPM device failure.
Minor
0xA003
TPM device failed self-test.
Minor
0xA022
Processor component encountered a mismatch error.
Major
0xA027
Processor component encountered a low voltage error.
Minor
0xA028
Processor component encountered a high voltage error.
Minor
0xA421
PCI component encountered a SERR error.
Fatal
0xA500
ATA/ATPI ATA bus SMART not supported.
Minor
0xA501
ATA/ATPI ATA SMART is disabled.
Minor
0xA5A0
PCI Express* component encountered a PERR error.
Minor
0xA5A1
PCI Express* component encountered a SERR error.
Fatal
0xA5A4
PCI Express* IBIST error.
Major
236
Revision
1.4
Intel® Server Board S1600JP TPS
Error Code
Appendix E: Video POST Code Errors
Error Message
Response
0xA6A0
DXE boot services driver. Not enough memory available to shadow a legacy option ROM.
Minor
0xB6A3
DXE boot services driver Unrecognized.
Major
Revision 1.4
237
Glossary
Intel® Server Board S1600JP TPS
Glossary
This appendix contains important terms used in the preceding chapters. For ease of use,
numeric entries are listed first (for example, “82460GX”) with alpha entries following (for
example, “AGP 4x”). Acronyms are then entered in their respective place, with non-acronyms
following.
Table 111. Glossary
Term
Definition
ACPI
Advanced Configuration and Power Interface
AP
Application Processor
APIC
Advanced Programmable Interrupt Control
ARP
Address Resolution Protocol
ASIC
Application Specific Integrated Circuit
BIOS
Basic Input/Output System
BIST
Built-In Self Test
BMC
Baseboard Management Controller
Bridge
Circuitry connecting one computer bus to another, allowing an agent on one to access the other
BSP
Bootstrap Processor
Byte
8-bit quantity
CATERR
On a catastrophic hardware event the core signals CATERR to the uncore. The core enters a halted
state that can only be exited by a reset
CBC
Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they
bridge the IPMB buses of multiple chassis.)
CEK
Common Enabling Kit
CHAP
Challenge Handshake Authentication Protocol
CMOS
In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes
of memory, which normally resides on the server board
DCMI
Data Center Management Interface
DHCP
Dynamic Host Configuration Protocol
DPC
Direct Platform Control
EEPROM
Electrically Erasable Programmable Read-Only Memory
EHCI
Enhanced Host Controller Interface
EMP
Emergency Management Port
EPS
External Product Specification
FBD
Fully Buffered DIMM
F MB
Flexible Mother Board
FRB
Fault Resilient Booting
FRU
Field Replaceable Unit
FSB
Front Side Bus
GB
1024 MB
GPIO
General Purpose I/O
GTL
Gunning Transceiver Logic
GPA
Guest Physical Address
HSC
Hot-Swap Controller
238
Revision
1.4
Intel® Server Board S1600JP TPS
Term
HPA
Hz
2
Definition
Host Physical Address
Hertz (1 cycle/second)
IC
Inter-Integrated Circuit Bus
IA
Intel Architecture
IBF
Input Buffer
®
ICH
I/O Controller Hub
IC MB
Intelligent Chassis Management Bus
IFB
I/O and Firmware Bridge
ILM
Independent Loading Mechanism
IMC
Integrated Memory Controller
INTR
Interrupt
IP
Internet Protocol
IPMB
Intelligent Platform Management Bus
IPMI
Intelligent Platform Management Interface
IR
Infrared
ITP
In-Target Probe
KB
1024 bytes
KCS
Keyboard Controller Style
LAN
Local Area Network
LCD
Liquid Crystal Display
LED
Light Emitting Diode
LPC
Low Pin Count
LSB
Least Significant Bit
LUN
Logical Unit Number
MAC
Media Access Control
MB
1024KB
ME
Management Engine
MD2
Message Digest 2 – Hashing Algorithm
MD5
Message Digest 5 – Hashing Algorithm – Higher Security
ms
Milliseconds
MTTR
Memory Type Range Register
Mux
Multiplexor
NIC
Network Interface Controller
NMI
Nonmaskable Interrupt
OBF
Output Buffer
OEM
Original Equipment Manufacturer
Ohm
Unit of electrical resistance
PECI
Platform Environment Control Interface
PEF
Platform Event Filtering
PEP
Platform Event Paging
PIA
Platform Information Area (This feature configures the firmware for the platform hardware)
PLD
Programmable Logic Device
PMI
Platform Management Interrupt
POST
Power-On Self Test
Revision 1.4
Glossary
239
Glossary
Term
Intel® Server Board S1600JP TPS
Definition
PSMI
Power Supply Management Interface
PWM
Pulse-Width Modulation
QPI
QuickPath Interconnect
RAM
Random Access Memory
RASUM
Reliability, Availability, Serviceability, Usability, and Manageability
RISC
Reduced Instruction Set Computing
ROM
Read Only Memory
RTC
Real-Time Clock (Component of ICH peripheral chip on the server board)
RMM3
Remote Management Module 3
SDR
Sensor Data Record
SECC
Single Edge Connector Cartridge
SEEPROM
Serial Electrically Erasable Programmable Read-Only Memory
SEL
System Event Log
SIO
Server Input/Output
SMBUS*
System Management BUS
SMI
Server Management Interrupt (SMI is the highest priority nonmaskable interrupt)
SMM
Server Management Mode
SMS
Server Management Software
SNMP
Simple Network Management Protocol
TBD
To Be Determined
TDP
Thermal Design Power
TIM
Thermal Interface Material
UART
Universal Asynchronous Receiver/Transmitter
UDP
User Datagram Protocol
UHCI
Universal Host Controller Interface
URS
Unified Retention System
UTC
Universal time coordinate
UUID
Universally Unique Identifier
VID
Voltage Identification
VRD
Voltage Regulator Down
VT
Virtualization Technology
Word
16-bit quantity
ZIF
Zero Insertion Force
240
Revision
1.4
Intel® Server Board S1600JP TPS
Reference Documents
Reference Documents

ACPI 3.0: http://www.acpi.info/spec.htm

IPMI 2.0

Data Center Management Interface Specification v1.0, May 1, 2008:
www.intel.com/go/dcmi

PCI Bus Power Management Interface Specification 1.1: http://www.pcisig.com/

PCI Express* Base Specification Rev 2.0 Dec 06: http://www.pcisig.com/

PCI Express* Card Electromechanical Specification Rev 2.0: http://www.pcisig.com/

PMBus*: http://pmbus.org

SATA 2.6: http://www.sata-io.org/

SMBIOS 2.4

SSI-EEB 3.0: http://www.ssiforum.org

USB 1.1: http://www.usb.org

USB 2.0: http://www.usb.org

Windows* Logo/SDG 3.0

Intel® Dynamic Power Technology Node Manager 1.5 External Interface
Specification using IPMI, 2007. Intel Corporation.

Node Power and Thermal Management Architecture Specification v1.5, rev.0.79.
2007. Intel Corporation.

Intel® Server System Integrated Baseboard Management Controller Core External
Product Specification, 2007. Intel Corporation.

Intel® Thurley Server Platform Services IPMI Commands Specification 2007. Intel
Corporation.

Intel® Server Safety and Regulatory, 2011. Intel Corporation. Intel® order number
G68018-003.

Intelligent Platform Management Bus Communications Protocol Specification,
Version 1.0, 1998. Intel Corporation, Hewlett-Packard* Company, NEC* Corporation,
Dell* Computer Corporation.

Platform Environmental Control Interface (PECI) Specification, Version 2.0. Intel
Corporation.

Platform Management FRU Information Storage Definition, Version 1.0, Revision 1.2,
2002. Intel Corporation, Hewlett-Packard* Company, NEC* Corporation, Dell*
Computer Corporation. http://developer.intel.com/design/servers/ipmi/spec.htm.