Contents
Cautions ..................................................2
Wireless Non-contact
Infrared Body / Surface thermometer
ADF-B38A
Special Features .....................................2
Measurement Principle ...........................2
Product scope .........................................3
The component of product ......................3
Setting .....................................................3
C / OF unit conversion formula ...............4
O
Method of measurement .........................4
Connect iOS device via Bluetooth ..........5
Memory Function ....................................6
Replacing the Batteries ...........................6
Cleaning and Care ..................................6
Display Message .................................... 7
Product Specifications .............................8
Thank you for purchasing the non-contact
electronic thermometer, Please read through this
manual before using the product.
Cautions
1. Do not drop or shock the unit.
2. Do not immerse the unit into water.
3. Keep the unit out of reach of children.
4. Avoid touching the lens with bare hand.
5. Do not use in areas with strong electromagnetic
interference.
6. Consult your physician if the reading is out of normal
body temperature range.
7. Remove the batteries from the thermometer if the
unit will not be used for an extended period of time.
This will prevent battery leakage causing damage
to the thermometer.
8. If the unit is not working properly, please contact
customer service.
9. Do not disassemble the unit, Open the battery
cover only when replacing batteries.
Connect iOS device via Bluetooth
1. Installation
Prior to first use, Download and install “Andesfit Health”
application on your device. (Bluetooth 4.0 capabilities,
e.g. iOS 7.0 or above iPhone 4S,5,6,iPad3 gen or above
Android 4.3)
2. Open “Andesfit Health” application
Pressure icon on Measurement screen.
C / OF unit conversion formula
O
Power/Measure
Method of measurement
Battery cover
Back
Front
Setting
-4-
Display Message
Display
message
Product specification
Project
Infrared measuring
Measuring mode
Surface/body temperature
Measuring distance
1~5cm
Accuracy
Situation
Solution
Ambient temperature
is out of operating
range (10-40OC)
Sensor error
Allow the thermometer
remain in room
temperature (10-40OC)
for 30 minutes.
Please contact with the
customer service.
Memory error
Please contact with the
customer service.
Temperature measured
is higher than normal
human temperature
range
(Body above 42.2OC;
Surface above 60OC)
Check the measured
object and take a
new measure.
Temperature measured
is lower than normal
human temperature
range (Body below 32OC;
Body below 20OC)
Check the measured
object and take a
new measure.
Low battery
Replace batteries.
Content
Measuring type
Measuring
Surrounding
Accuracy
32~42.2 C
16~35 C
±0.3OC
O
- 7-
O
(out)32~42.2OC (out)16~35OC
Indicator Functions
LCD display
Low voltage tip
<2V±0.1
Display resolution
0.1OC
Unit
O
Work surrounding
10OC~40OC
Storage temperature
-20OC~+55 OC
Automatic shutdown
1 minute after not being used
±0.4OC
AndesFit ltd
C , OF
Memory
50 Group memory
Battery
2 x AA
Size
159×87.5×45.5 mm
Weight
About 98g (Not including batteries)
Unit 513 Lakeside 1, No.8 Science Park West Ave.,
Hong Kong Science Park, Hong Kong
Customer Services: (852) 35951880
www.andesfit.com
Truly Instrument Ltd.
2/F., Chung Shun Knitting Centre,
1-3 Wing Yip St, Kwai Chung,
N.T., HONG KONG
EC-REPRESENTATIVE:
Wellkang Ltd t/a Wellkang Tech Consulting
Suite B, 29 Harley Street,
LONDON W1G 9QR,
United Kingdom
1. Use a soft, dry cloth to clean the exterior of the
thermometer.
- 6-
1. Pressing "Power" and display.
2. Press "MODE" key to select temperature
measurement mode (body or surface) :
(1) Thermometer is straight to the forehead, and
distance is 1~5cm.
1~5cm
Cleaning and Care
- 5-
F=1.8xOC+32
O
- 3-
Memory Function
Products use battery by 2, when a battery symbol
appears and flash in the screen, and replace the
battery as soon as possible.
• Note:
1. Open the battery cover to
replace batteries, and
place the battery is the
Pull and open the
battery cover from
location of the negative
then on
electrode correctly.
2. If not use, please take out
the battery so as to
protect instrument.
Cranium
Memory
Mode
- 2-
2. Keep the thermometer away from direct sunlight,
dust and contamination environment.
3. Store the thermometer in normal room
temperature, or within 10-40oC.
4. Don't touch the lens with the finger.
5. Can use less than 75% of the rubbing alcohol to
clean the lens.
Replacing the Batteries
Set
Surface
Measuring the temperature of the body and the
surface on forehead with infrared. Products the same
built-in infrared sensor and related hardware,
software, can sense the analyte, analysis and records
3. Press the “Temperature” button.
4. Press the “Start Measurement” button.
5. When the measurement is complete, the
temperature will display on Thermometer monitor &
press “Save”.
6. All the measurement data will be saved in the app.
1. Pressing "Power" and display and showen the last
records.
2. Pressing the "MEM" key to switch record shows
upper
* LCD display test records and record number.
3. Switch mode
* Pressing the "MODE" key to switch MODE.
LCD
Body
4. Save setting value.
Pressing the "SET" key for 4 seconds to save
the value and exit setting mode. If F-04 value is
"YES", The thermometer will be delete all records.
(2) Pressing and holding the "Measure" key and
move thermometer scaning forehead.
(3) Release the "Measure" key to finish
measurement and display the result on LCD.
(4) Turn off: The thermometer will trun off
automatically without use for 1 minute.
- 1-
• Note:
The correct method of use is the key to test the
accuracy of the product. Please follow these
instructions, so as to avoid the infrared measurement
on the surrounding.
1. Testing temperature, as the showing in the figure,
instrument and the distance from the forehead
suggested in 1cm to 5cm.
2. Keep the body's temperature as the same as the
surrounding.
3. It should be avoided cold and any disease of cool
down the temperature.
4. Keep the Instrument's temperature as the same
as the surrounding.
5. Forbidden to use this instrument in the strong
sunshine place.
6. Measure suggestion: 3 times or so, every time
when to display up to a set of data shall prevail.
The component of product
1. Pressing the “SET” Key for 4 seconds, The
thermometer will be turn on and enter the setting
mode, the LCD display F-00 and alarm temperature
value.
2. Modify the setting value
Pressing the "MODE" or "MEM" key to change the
value.
3. Switch to other setting item:
Press the "SET" key to switch to other item.
F-00: Alarm Temperature value.
Measurement Principle
Rev.01 20150823
Product scope
For measurement of body and surface temperature.
Special Features
1. Measurement range: Body: 32~42.2OC / 90~108OF
Surface: 10~60OC / 50~140OF
2. Free to set alarm temperature.
3. Non-contact measurement, avoid cross infection.
4. Memory for 50 readings.
5. Auto power off without use it.
6. Unit of Measure: OC/OF.
7. Backlight.
F-01: Offset value for body mode(-2.0~+2.0).
F-02: Temperature Unit (OC/OF).
F-03: Delete records(Yes,No)
and environmental temperature, and once the user
has to pass the instrument near certain parts of the
body (forehead), and press the measure button can
immediately active infrared radiation sensor.
- 8-