MOV82747_EPLE04-03
EPLE04-03
WALL MOUNTED UNIT
Daikin air conditioners for your home
NEW
NEW
FTKS/FTXS-C
FTKS/FTXS-B
remote
control
(standard)
centralised
remote
control
(optional)
indoor unit FTK/XS20,25,35C
horizontal
auto
swing
vertical
auto swing
auto
restart
powerful
mode
auto cooling/
heating
changeover
(FTXS)
auto fan
speed
fan only
(FTKS)
fan speed
5 steps
photocatalytic
deodorising
filter
air
purification
filter
NEW
• Flat front panel: its stylish appearance fits easily within any interior decor and is more easy
to clean
• Lightweight and compact
• The movement sensor automatically saves power consumption in unoccupied rooms
• The home leave operation saves energy during absence
• Automatic horizontal and vertical auto swing ensures uniform air flow and temperature
distribution
• 3D-air flow (50,60,71 class only)
• Powerful mode can be selected for rapid cooling and heating
• Air purification filter with photocatalytic deodorising function:
- deodorises the air
- powerfully decomposes cigarette and pet odours
- removes house dust and pollen
- deactivates bacteria and viruses
• Indoor / outdoor* unit silent operation:
“Silent” buttons on the remote control lower the operating sound of the indoor and/or
outdoor unit by 3dB(A) each
(*only in combination with RK/XS-B outdoor units)
movement
sensor
dry
programme
self
diagnosis
night set
mode
whisper
quiet
energy
efficiency
home leave
operation
multi model
application
24 hour
timer
indoor
unit silent
operation
outdoor
unit silent
operation
(RK/XS-B)
night quiet
mode
MKS/MXS
(cooling
appl. only)
• Night quiet mode automatically reduces the operating sound of the outdoor unit by
3dB(A) at night (multi outdoors in cooling mode only)
• Up to 4 indoor units can be connected to 1 Multi outdoor unit. All
indoor units are individually controllable with a remote control
and do not need to be installed in the same room. They operate
simultaneously within the same cooling or heating mode.
• The outdoor unit can be installed on a roof or terrace or placed
against an outside wall.
• The outdoor unit is fitted with a swing compressor,
renowned for its low noise and energy efficiency.
•
•
•
•
outdoor unit
RK/XH20,25,35C
The remote control has a 24 hour timer
The indoor unit also has a start/stop button mounted on the front panel
Up to 5 indoor units can be regulated from a single centralised control
Purpose-designed holder provided for the remote control
(20,25,35 class) (50,60,71 class)
Cyan Magenta Yellow Black
MOV82747_EPLE04-03
The use of integrated inverter control ensures maximum comfort and efficiency.
• PAM inverter technology
The PAM (Pulse Amplitude Modulation) inverter technology results in better
cooling and heating performances and lower energy consumption.
With a minimum of power input you get a maximum of comfort.
Start-up time
reduced by 1/3
• Short start-up cycle
Inverter control enables the required room temperature
to be achieved quicker than with non-inverter units, in fact,
start-up time is reduced by one third.
• 30% less power consumption
The inverter controller detects changes in room or outdoor
conditions and adjusts the indoor temperature to compensate
within seconds.
Rapid response reduces power consumption to 30% lower than
that of non-inverter systems.
Standard
heat pump system
Small temperature
difference
Inverter
heat pump system
30% LESS POWER
CONSUMPTION
This filter is an anti-bacterial and deodorising filter, which powerfully decomposes cigarette and pet odours and also
restraints the reproduction of bacteria or micro-organisms caught in the filter.
NEW
The previous air purification filter and photocatlytic
deodorising filter have now been combined into 1 filter:
2 advantages:
Unlike the previous photocatalytic deodorising filter, this filter does not need to be exposed to the sun. The filter
contains active components that are regenerated by the room light and does not have to be replaced for 3 years. It is
sufficient to soke it in water once every 6 months (= long lasting effect!)
Cyan Magenta Yellow Black
MOV82747_EPLE04-03
During the occupant’s absence, the indoor temperature can be maintained at a preset level, according to user
preference. The home leave operation can be activated or deactivated via the remote control. This useful function saves
energy when the room is empty or when the occupant goes to bed. It also enables the room temperature to return
quickly to the set temperature. A lamp on the indoor unit indicates that the home leave operation has been activated.
While out of the home
One Push
Push again
When you go out push the “Home
leave operation” button, and the air
conditioner will adjust capacity to
reach the preset temperature for
“Home leave operation”.
When you return, you will be
welcomed by a comfortable
air-conditioned room.
Push the “Home leave operation”
button again, and the air conditioner
will adjust capacity to the set
temperature for normal operation.
Circulates room air all around the room evenly to decrease uneven temperature differences
(50,60,71 class only). This function can be started by pushing both horizontal and vertical swing
buttons simultaneously.
When the air flow is set to “Quiet mode” via the remote control, the operating sound of the indoor unit is reduced by
3dB(A). This function is useful when studying or sleeping.
When the “silent button” is selected on the remote control of the indoor unit , the operating sound of the outdoor unit
is reduced by 3dB(A), by lowering the revolution speed of the compressor and outdoor fan.
This is a useful means of reducing the sound level, particularly during night time operation in order not to cause local
disturbances.
Notes in case of Multi installations:
In the event that “Priority room setting” is not active, the “Outdoor unit silent mode” can be activated only if the
‘silent’ command is selected on ALL indoor units.
In case “Priority room setting” is active, the “Outdoor unit silent mode” can be activated merely by selecting the ‘silent’
command on the indoor unit in the room set as ‘priority room’.
It is possible to reduce the outdoor unit sound level automatically by removing a jumper wire in the outdoor unit. This
function only works in cooling mode.
Night quiet mode automatically starts when the outdoor temperature has dropped by 6°C or more below the maximum
temperature recorded during the day. (This function can be deactivated if the jumper wire is kept and reinstalled in
the outdoor unit).
Outside
temp.
DAY
NIGHT
Temp.
difference
(5°C)
Time
Start Night
quiet mode
Cyan Magenta Yellow Black
Stop
MOV82747_EPLE04-03
Capacity and power input
PAIR - COOLING ONLY
(air cooled)
INDOOR UNIT
OUTDOOR UNIT
Capacity (min.-nom.-max.)
Power input (min.-nom.-max.)
EER
Energy label
Annual energy consumption
cooling
cooling
kW
kW
cooling
cooling
kWh
PAIR - HEAT PUMP
(air cooled)
INDOOR UNIT
OUTDOOR UNIT
Capacity (min.-nom.-max.)
cooling
heating
cooling
heating
kW
kW
kW
kW
cooling
heating
cooling
kWh
Power input (min.-nom.-max.)
EER
COP
Energy label
Annual energy consumption
FTKS20CVMB
RKH20CVMB
FTKS25CVMB
RKH25CVMB
FTKS35CVMB
RKH35CVMB
FTKS50BVMB
RKS50BVMB9
FTKS60BVMB FTKS71BVMB
RKS60BVMB9 RKS71BVMB9
1.3~2.0~2.6
1.3~2.25~3.0 1.4~3.15~3.8 0.90~5.00~5.80 0.90~6.00~6.70 0.90~7.10~8.00
0.43~0.62~0.945 0.43~0.70~1.20 0.46~1.045~1.425 0.45~1.66~2.30 0.45~2.12~2.45 0.45~2.53~3.07
3.23
3.21
3.01
3.01
2.83
2.81
A
A
B
B
C
C
310
350
523
830
1,060
1,265
FTXS20CVMB
RXH20CVMB
1.3~2.0~2.6
1.3~2.6~4.0
0.43~0.62~0.945
0.35~0.76~1.31
3.23
3.42
A
B
310
FTXS25CVMB
RXH25CVMB
FTXS35CVMB
RXH35CVMB
FTXS50BVMB
RXS50BVMB
1.3~2.25~3.0 1.4~3.15~3.8 0.90~5.00~5.80
1.3~2.85~4.5
1.4~3.6~5.0 0.90~5.80~7.50
0.43~0.70~1.20 0.46~1.045~1.425 0.45~1.66~2.30
0.35~0.835~1.61 0.405~1.055~1.90 0.45~1.70~2.58
3.21
3.01
3.01
3.41
3.41
3.41
A
B
B
B
B
B
350
523
830
FTXS60BVMB
RXS60BVMB
FTXS71BVMB
RXS71BVMB
0.90~6.00~6.70 0.90~7.10~8.00
0.90~7.00~8.00 0.90~8.50~9.50
0.45~2.12~2.45 0.45~2.53~3.07
0.45~2.09~3.10 0.45~2.63~3.80
2.83
2.81
3.35
3.23
C
C
C
C
1,060
1,265
Note : 1) Energy label: scale from A (most efficient) to G (less efficient)
2) The energy label Directive 2002/31/EC will enter into force once the relevant measurement standard will be published in the European Official Standard.
3) Annual energy consumption: based on average use of 500 running hours per year at full load (=nominal conditions)
MULTI - COOLING ONLY
(air cooled)
Max. n° of
indoor units
Max. cooling
capacity (kW)
Max. PI
cooling (kW)
Max. heating
capacity (kW)
Max. PI
heating (kW)
2MKS40BVMB
3MKS50BVMB
4MKS58BVMB
4MKS75BVMB
4MKS90BVMB
MULTI - HEAT PUMP
(air cooled)
2
3
4
4
4
4.20
6.46
6.60
9.47
9.40
1.49
2.18
2.22
3.52
3.35
-
-
2MXS40BVMB
3MXS52BVMB
4MXS68BVMB
4MXS80BVMB
2
3
4
4
4.20
6.50
8.67
9.45
1.49
2.42
3.47
3.04
4.70
7.34
10.64
11.00
1.42
2.44
3.07
3.04
Note : For more detailed information about capacities and power input, please refer to our Multi Model catalogue or check with your local dealer.
FTK/XS20,25,35CVMB
FTK/XS50BVMB
FTK/XS60,71BVMB
Specifications indoor units
COOLING ONLY
Dimensions
Weight
Front panel colour
Air flow rate
Fan speed
Sound pressure level
Sound power level
Piping connections
HxWxD
cooling (H/L/SL)
cooling (H/L/SL)
cooling (H)
liquid
gas
drain
mm
kg
m3/min
steps
dB(A)
dB(A)
mm
mm
mm
Heat insulation
HEAT PUMP
Dimensions
Weight
Front panel colour
Air flow rate
Fan speed
Sound pressure level
Sound power level
Piping connections
HxWxD
cooling (H/L/SL)
heating (H/L/SL)
cooling (H/L/SL)
heating (H/L/SL)
cool./heat. (H)
liquid
gas
drain
Heat insulation
Cyan Magenta Yellow Black
mm
kg
m3/min
m3/min
steps
dB(A)
dB(A)
dB(A)
mm
mm
mm
FTKS20CVMB
FTKS25CVMB
7.5
273x784x195
7.5
7.7/4.2/3.6
7.7/4.2/3.6
38/25/22
56
38/25/22
56
ø6.4
ø9.5
ø18.0
FTXS20CVMB
FTXS25CVMB
7.5
273x784x195
7.5
7.7/4.2/3.6
7.8/5.3/4.6
7.7/4.2/3.6
7.8/5.3/4.6
38/25/22
38/28/25
56/56
38/25/22
38/28/25
56/56
ø6.4
ø9.5
ø18.0
FTKS35CVMB
FTKS50BVMB
290x795x238
7.5
9
white
7.7/4.4/3.8
11.4/8.0/7.1
5 steps, silent and auto
39/26/23
44/35/32
57
63
FTKS60BVMB
FTKS71BVMB
290x1,050x238
12
12
16.2/11.4/10.2 16.7/11.6/10.6
45/36/33
63
ø6.4
ø12.7
46/37/34
63
ø15.9
ø18.0
both liquid and gas pipes
FTXS35CVMB FTXS50BVMB
290x795x238
7.5
9
white
7.7/4.4/3.8
11.4/8.0/7.1
8.1/5.3/4.6
12.6/8.9/7.7
5 steps, silent and auto
39/26/23
44/35/32
39/29/26
42/33/30
57/57
63/60
FTXS60BVMB
16.2/11.4/10.2 16.7/11.6/10.6
17.4/12.7/11.4 18.5/13.5/12.1
45/36/33
44/35/32
63/62
ø6.4
ø12.7
46/37/34
46/37/34
63/63
ø15.9
ø18.0
both liquid and gas pipes
FTXS71BVMB
290x1,050x238
12
12
MOV82747_EPLE04-03
Control systems
FTK/XS-C/B
20
25
35
Wiring adapter for time clock/ normal open contact
remote control (1)
normal open pulse contact
Centralised control board
up to 5 rooms (2)
Central remote control
Unified ON/OFF control
Schedule timer
Interface adapter (3)
50
60
71
KRP413A1S
KRP413A1S
KRC72
DCS302B51
DCS301B51
DST301B51
KRP928A2S
(1) Wiring adapter is supplied by Daikin. Timer and other devices: field supply.
(2) Wiring adapter is also required for each indoor unit.
(3) For DIII-NET adapter
Accessories indoor units
FTK/XS-C/B
20
25
Air purification filter with
photocatalytic deodorising function (with frame)
Air purification filter with photocatalytic deodorising function (without frame)
Anti-theft protection for remote control
35
50
60
71
KAF918A43
KAF918A44
KKF917A4
KKF910A4
RKS50,60,71BVMB9
RXS50,60,71BVMB
RK/XH20,25,35CVMB
Specifications outdoor units
PAIR - COOLING ONLY
Dimensions
HxWxD
Weight
Casing colour
Sound pressure level
cooling (H/L)
Sound power level
cooling (H)
Compressor
Refrigerant type
Amount of additional charge
Maximum piping length
Maximum level difference
Standard operation range cooling
from~to
PAIR - HEAT PUMP
Dimensions
Weight
Casing colour
Sound pressure level
HxWxD
dB(A)
dB(A)
from~to
from~to
RKH20CVMB
RKH25CVMB
31
560x695x265
31
46/*
61
46/*
61
RXH20CVMB
15
15
10~46
RXH25CVMB
31
560x695x265
31
g/m
m
m
°CDB
mm
kg
cooling (H/L)
heating (H/L)
cooling/heating (H)
Sound power level
Compressor
Refrigerant type
Amount of additional charge
Maximum piping length
Maximum level difference
Standard operation range cooling
heating
mm
kg
dB(A)
dB(A)
dB(A)
g/m
m
m
°CDB
°CWB
46/*
47/*
61/62
RKH35CVMB
33
RKS50BVMB9 RKS60BVMB9
55
49/*
64
52/*
66
49
ivory white
48/*
47/*
63
63
hermetically sealed swing type
R-410A
20 (for piping length exceeding 10m)
RXH35CVMB
33
RKS71BVMB9
735x825x300
53
30
20
-10 (-15**) ~46
RXS50BVMB RXS60BVMB
735x825x300
53
49
ivory white
46/*
48/*
47/*
49/*
47/*
48/*
48/*
49/*
61/62
63/63
63/64
64/64
hermetically sealed swing type
R-410A
20 (for piping length exceeding 10m)
15
30
15
20
10~46
-10~46
-10~20
-15~18
RXS71BVMB
55
52/*
52/*
66/66
* This information was not available at the time of publication
** Possibility to extend the operation range down to -15°C by turning ON the switch on the outdoor unit PCB. In this case, the unit will stop operation at -20°C or lower and will
recover when temperature rises again.
Cyan Magenta Yellow Black
MOV82747_EPLE04-03
3MKS50BVMB / 4MKS58,75BVMB
3MXS52BVMB / 4MXS68BVMB
2MK(X)S40BVMB
4MKS90BVMB
4MXS80BVMB
Specifications outdoor units
2MKS40BVMB
MULTI - COOLING ONLY
Dimensions
HxWxD
Weight
Casing colour
Sound pressure level
cooling (H/L)
Sound power level
cooling (H)
Compressor
Refrigerant type
Amount of additional charge
Maximum
for total of each room
piping length
for one room
Maximum
between indoor and outdoor
level difference
between indoor units
Standard operation range cooling
from~to
MULTI - HEAT PUMP
Dimensions
Weight
Casing colour
Sound pressure level
Sound power level
47/43
62
dB(A)
dB(A)
g/m
m
m
m
m
°CDB
3MKS50BVMB** 4MKS58BVMB**
640x685x285
39
mm
kg
20(20m or more)
30
20
10
7.5
10~46
2MXS40BVMB**
640x685x285
39
HxWxD
mm
kg
cooling (H/L)
heating (H/L)
cooling (H)
heating (H)
dB(A)
dB(A)
dB(A)
dB(A)
47/43
48/44
60
61
g/m
m
m
m
m
°CDB
°CWB
20(20m or more)
30
20
10
7.5
10~46
-10~15.5
Compressor
Refrigerant type
Amount of additional charge
Maximum
for total of each room
piping length
for one room
Maximum
between indoor and outdoor
level difference
between indoor units
Standard operation range cooling
from~to
heating
from~to
4MKS75BVMB**
735x936x300
59
55
58
ivory white
46/43
46/*
48/*
59
59
61
hermetically sealed swing type
R-410A
chargeless
45
45
60
25
15
7.5
-10~46
3MXS52BVMB**
4MXS68BVMB**
735x936x300
735x936x300
55
59
ivory white
46/*
48/*
47/*
49/*
59
61
60
62
hermetically sealed swing type
R-410A
20(30m or more)
20(30m or more)
45
60
25
15
7.5
-10~46
-15~15.5
4MKS90BVMB**
908x900x320
66
48/*
61
70
4MXS80BVMB**
908x900x320
73
48/*
49/*
61
62
20(40m or more)
70
*This information was not available at the time of publication.
**At least 2 indoor units should be connected to this Multi outdoor unit.
Accessories outdoor units
Air direction adjustment grille
Note: 1)
2)
3)
4)
5)
6)
7)
PAIR (20,25,35 class) / MULTI (40 class)
PAIR (50,60,71 class) / MULTI (50~90 class)
KPW937A4
KPW945A4
VM = 1~,220~240/220-230V,50Hz/60Hz
Nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB • outdoor temperature 35°CDB • refrigerant piping length 7.5m • level difference 0m.
Nominal heating capacities are based on: indoor temperature 20°CDB • outdoor temperature 7°CDB/6°CWB • refrigerant piping length 7.5m • level difference 0m.
Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
Units should be selected on nominal capacity. Max. capacity is limited to peak periods.
The sound pressure level is measured via a microphone at a certain distance from the unit (for measuring conditions: please refer to the technical databooks).
The sound power is an absolute value indicating the “power” which a sound source generates.
Daikin products are distributed by:
Daikin Europe N.V. is approved by LRQA for its
Quality Management System in accordance with the
ISO9001 standard. ISO9001 pertains to quality assurance
regarding design, development, manufacturing as
well as to services related to the product.
ISO14001 assures an effective environmental
management system in order to help protect human
health and the environment from the potential
impact of our activities, products and services and to
assist in maintaining and improving the quality of the
environment.
Daikin units comply with the European regulations
that guarantee the safety of the product.
Specifications are subject to change without prior notice.
Zandvoordestraat 300
B-8400 Oostende, Belgium
Internet: http://www.daikineurope.com
Cyan Magenta Yellow Black
Daikin Europe N.V. is participating in the EUROVENT
Certification Programme. Products are as listed in the
EUROVENT Directory of Certified Products. Multi units
are certified by Eurovent for combinations up to two
indoor units.
EPLE04-03 / 4.000 / 11/03 / La Movida
Printed on non-chlorinated paper / Printed in Belgium
Daikin’s unique position as a manufacturer of air conditioning equipment,
compressors and ozone-friendly refrigerants has led to its close involvement in
environmental issues.
For several years Daikin has had the intention to become a leader in the provision
of environmental friendly products. This challenge demands the eco design and
development of a wide range of products and an energy management system;
which involves energy conservation and reduction of waste.