Patton electronics 2173R User manual
Patton Electronics 2173R is an industrial-grade Ethernet extender designed for long-distance transmission of Ethernet data over twisted-pair copper wire. With its ruggedized design, it's ideal for use in harsh environments, extending network connectivity up to 3,000 feet (914 meters) away from the main network switch.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
USER
MANUAL
MODEL 2173R
Ruggedized High Speed
Ethernet Extender
An ISO-9001Certified
Company
Part# 07M12173R-UM
Rev. B
Revised 2/3/12
SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
CONTENTS
Warranty Information ................................................................. 4
Compliance ................................................................................... 4
EMC Compliance:......................................................................... 4
Low-Voltage Direcive (Safety): ..................................................... 4
PSTN: ........................................................................................... 4
Radio and TV Interference (FCC Part 15) .................................... 4
CE Declaration of Conformity ....................................................... 5
Authorized European Representative ........................................... 5
Service.......................................................................................... 5
Safety When Working With Electricity .......................................... 6
General Information.................................................................... 8
Features........................................................................................ 8
Description.................................................................................... 8
Installation................................................................................... 9
Connecting the Twisted-Pair Line Interface ................................ 10
Connecting the 10/100Base-T Ethernet Interface ...................... 11
Connecting Power ...................................................................... 12
Configuration ............................................................................ 12
Configuring the hardware DIP switches...................................... 12
Configuring DIP Switch S1 ......................................................... 14
Operation................................................................................... 14
Power Up .................................................................................... 14
Front Panel LED Status Monitors ............................................... 15
Specifications ........................................................................... 16
LAN Connection ......................................................................... 16
Transmission Line ....................................................................... 16
CopperLINK Line Rate and CopperLINK Distance .................... 16
LED Status Indicators ................................................................. 16
Power Supply .............................................................................. 16
Temperature Range .................................................................... 16
Humidity ...................................................................................... 16
Dimensions ................................................................................. 16
Replacement Parts and Accessories...................................... 17
Model 2173R Interface Pin Assignment.................................. 18
10/100Base-T Interface .............................................................. 18
RJ-45 .......................................................................................... 18
CopperLINK Interface ................................................................ 18
RJ-45 .......................................................................................... 18
2
Sample Rates/Distance Chart, Based on 24 AWG (0.5 MM) . 19
3
1.0 WARRANTY INFORMATION
Patton Electronics
warrants all Model 2173R components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not performs as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall
Patton Electronics
be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product.
Patton Electronics
specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
Note
Conformity documents of all Patton products can be viewed online at www.patton.com under the appropriate product page.
1.1 COMPLIANCE
EMC Compliance:
• FCC Part 15, Class A
• EN55022, Class A
• EN55024
• A-tick
Low-Voltage Direcive (Safety):
• IEC/EN60950-1, 2nd Edition
• AS/NZS 60950-1, A-tick
PSTN:
• This device is not intended nor approved for connection to the PSTN.
1.2 RADIO AND TV INTERFERENCE (FCC PART 15)
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television
4
reception. This equipment has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, reorienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
1.3 CE DECLARATION OF CONFORMITY
We certify that the apparatus described above conforms to the requirements of Council Directive 2004/108/EC on the approximation of the laws of the member states relating to electromagnetic compatibility; and
Council Directive 2006/95/EC on the approximation of the laws of the member states relating to electrical equipment designed for use within certain voltage limits.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.
1.4 AUTHORIZED EUROPEAN REPRESENTATIVE
D R M Green, European Compliance Services Limited.
Avalon House, Marcham Road, Abingdon, Oxon OX14 1UD, UK
1.5 SERVICE
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Services at:
• Tel:
+1 (301) 975-1007
• Email:
• URL:
http://www.patton.com
Note
Packages received without an RMA number will not be accepted.
5
1.6 SAFETY WHEN WORKING WITH ELECTRICITY
• This device contains no user serviceable parts. This device can only be repaired by qualified service personnel.
WARNING
• Do not open the device when the power cord is connected. For systems without a power switch and without an external power adapter, line voltages are present within the device when the power cord is connected.
• For devices with an external power adapter, the power adapter shall be a listed Limited Power Source. The mains outlet that is utilized to power the device shall be within 10 feet (3 meters) of the device, shall be easily accessible, and protected by a circuit breaker in compliance with local regulatory requirements.
• For AC powered devices, ensure that the power cable used meets all applicable standards for the country in which it is to be installed.
• For AC powered devices which have 3 conductor power plugs (L1, L2 & GND or Hot, Neutral & Safety/
Protective Ground), the wall outlet (or socket) must have an earth ground.
• For DC powered devices, ensure that the interconnecting cables are rated for proper voltage, current, anticipated temperature, flammability, and mechanical serviceability.
• WAN, LAN & PSTN ports (connections) may have hazardous voltages present regardless of whether the device is powered ON or OFF. PSTN relates to interfaces such as telephone lines, FXS, FXO, DSL, xDSL,
T1, E1, ISDN, Voice, etc. These are known as “hazardous network voltages” and to avoid electric shock use caution when working near these ports. When disconnecting cables for these ports, detach the far end connection first.
• Do not work on the device or connect or disconnect cables during periods of lightning activity.
6
In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic
Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
WARNING
This device is NOT intended nor approved for connection to the PSTN. It is intended only for connection to customer premise equipment.
WARNING
When the 2173R is mounted, it shall be secured in such a way as to withstand a vertical shear force of 50N or 14 pounds.
WARNING
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermittent failures. Do the following to prevent ESD:
• Always follow ESD prevention procedures when removing and replacing cards.
• Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.
• To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.
7
2.0 GENERAL INFORMATION
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for one year for parts and labor. If any questions or problems arise during installation or use of this product, contact Patton Electronics Technical
Support at +1 (301) 975-1007.
2.1 FEATURES
• Variable rate CopperLINK extender - Easy to configure
• Auto-MDIX Ethernet
• Configurable 10/100, Full/Half, and Auto-Negotiating Ethernet
• Extends network connections up to 5,500 ft (1.6 km) over 2-wire 24-
AWG unconditioned lines
• Auto-Rate line rates up to 100 Mbps downstream/70 Mbps upstream
• Symmetric or asymmetric settings via DIP switch
• Transparent operation
• LED indicators for Power, Link, Ethernet Link & Activity, and Remote/Local
2.2 DESCRIPTION
The Patton Electronics Model 2173R Ruggedized Ethernet Extender provides high-speed LAN connections between peered Ethernet LANs, remote PCs, or any other network enabled 10/100Base-T device.
Operating in pairs, one Model 2173R or 2173 is configured as the (L) Local unit located at one end of the LAN extension and the other Model 2173R or 2173 is configured as the (R) Remote unit at the other end. These units can automatically forward LAN broadcasts, multicasts, and frames across a 2-wire voice-grade twisted-pair link. The data is passed transparently
(unmodified) through the 2173Rs or 2173s. The 2173Rs automatically add and delete MAC addresses, only passing packets across the CopperLINK link that are meant for the remote peered LAN.
8
Figure 1.
Typical application
The pair of 2173R and 2173 models work together to create a transparent extension between two peered Ethernet LANs. Figure 1 shows a typical point-to-point application.
3.0 INSTALLATION
CAUTION
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability.
To install the 2173R Ethernet Extender, do the following:
1. Connect the line interface between the units (refer to section 3.1,
“Connecting the Twisted-Pair Line Interface” on page 10)
Note
See Figure 2 for the standalone unit’s rear panel arrangements.
2. Connect the Ethernet interface (refer to section 3.2, “Connecting the
10/100Base-T Ethernet Interface” on page 11).
3. Connect the power plug (refer to section 3.3, “Connecting Power” on page 12).
9
2173R
(RJ-45)
Line
Pow er
5V; 0
.6A
Ethe rnet
2 1
Power jack
Ethernet port 1
Ethernet port 2
CopperLINK
twisted-pair
RJ-45 interface
Figure 2.
Model 2173R panel
3.1 CONNECTING THE TWISTED-PAIR LINE INTERFACE
CAUTION
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability.
The Model 2173R supports communication between two peer Ethernet
LAN sites over a distance of up to 5,500 ft (1.6 km) over 24 AWG
(0.5 mm) twisted-pair wire.
Note
Actual distance and link performance may vary depending on the environment and type/gauge of wire used.
Follow the steps below to connect the Model 2173R CopperLINK Interfaces.
Note
The Model 2173R units work in pairs. One of the units must be configured as a (L) Local unit, and the other unit must be configured as a (R) Remote unit. It does not matter which end is the L and which is the R. The link is always initiated by the R unit. As long as the L unit is powered on, the R unit can establish a link by being powered on or by having its power reset.
1. To function properly, the two Model 2173Rs must be connected together using twisted-pair, unconditioned, dry, metal wire, between
19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
10
2. The Model 2173R is equipped with either an RJ-45 interface jack that can be used on the CopperLINK interface. These CopperLINK interfaces are a two-wire interface. Observe the signal/pin relationships on the Model 2173R's CopperLINK interface jacks.
The RJ-45 connector on the Model 2173R's twisted pair interface is polarity insensitive and is wired for a two-wire interface. The signal/pin
relationship is shown in Figure 3.
1
2
3
4
5
6
7
8
1 (no connection)
2 (no connection)
3 (no connection)
4 (RING)
5 (TIP)
6 (no connection)
7 (no connection)
8 (no connection)
Figure 3.
Model 2173R (RJ-45) twisted pair line interface.
3.2 CONNECTING THE 10/100BASE-T ETHERNET INTERFACE
CAUTION
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability.
The shielded RJ-45 port labeled
Ethernet
is the Auto-MDIX10/100Base-
T interface. This port is designed to connect directly to a 10/100Base-T
network. Figure 4 shows the signal/pin relationships on this interface.
You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.
11
1
2
3
4
5
6
7
8
1 TX+/RX+
2 TX-/RX-
3 RX+/TX+
4 (no connection)
5 (no connection)
6 RX-/TX-
7 (no connection)
8 (no connection)
Figure 4.
Model 2173R 10/100Base-T RJ-45 Connector Pinout.
3.3 CONNECTING POWER
CAUTION
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability.
The Model 2173R does not have a power switch, so it powers up as soon as it is plugged in.
An external AC or DC power supply is available separately. This connection is made via the barrel jack on the rear panel of the Model 2173R. No configuration is necessary for the power supply (See Appendix B for domestic and international power supply and cord options).
DC power (supplied via the power supply jack to the 2173R) must meet the following requirements; DC power supplied must be regulated
+5VDC ±5%, 1.0A minimum. Center pin is +5V. The barrel type plug has a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.
4.0 CONFIGURATION
The Model 2173 has four DIP switches (S1) for configuring the unit for a wide variety of applications. This section describes switch locations and explains the different configurations..
4.1 CONFIGURING THE HARDWARE DIP SWITCHES
Using a small flat-tip screwdriver, remove the protective cover located on the underside of the Model 2173R (see Figure 5).
12
Hig h-S
Eth ern pe ed et E xte nd er
Figure 5.
Removing protective cover
Figure 6 on page 13 shows the orientation of the DIP switches in the On and Off positions.
Ruggedized High Speed Ethernet Extender
S1
ON
OFF
S1
ON
Switch toggle
1 2
3 4
Push toggle up for ON position
Push toggle down for
OFF position
ON
1 2 3 4
Figure 6.
DIP switch orientation
13
4.2 CONFIGURING DIP SWITCH S1
DIP switch S1 is where you configure the CopperLINK line. The following tables describe the configuration for the 2173.
Table 1:
2173 Firmware Configuration
Position
ON
OFF
S1-1
Master/
Slave
Slave
(CPE)
Master
(CO)
S1-2
Mode
Fast
Interleave
S1-3
Rate
Auto
25/25
S1-4
SNR
6dB
9dB
S1-2: Impulse Noise Protection
•
Fast Mode:
Direct data transmission with latency less than 1ms
•
Interleave Mode:
Provides data transmission protection for up to 250 ms impulse noise with latency less than 6 ms
S1-3: Rate Limit
S1-3
OFF
ON
Rate
25/25
Auto
S1-4: General Protection (Signal to Noise Ratio)
•
6dB:
Original line noise protection with 6dB SNR
•
9dB
: Better line noise protection with SNR up to 9dB
5.0 OPERATION
Once the Model 2173Rs are properly installed, they should operate transparently. No user settings required. This section describes reading the LED status monitors.
5.1 POWER UP
Before applying power to the Model 2173R, please review section 3.3,
“Connecting Power” on page 12 to verify that the unit is connected to the
appropriate power source.
14
5.2 FRONT PANEL LED STATUS MONITORS
The Model 2173R features six front panel LEDs that monitor power, the
Ethernet signals, the CopperLINK connection, and the remote/local setting. Figure 7 shows the front panel location of each LED. Table 2 on page 15 describes the LED functions.
Power LED
Link LED
Ethernet 1 LED
Ethernet 2 LED
Remote LED
Link
Power
Local LED
Ethernet 1
Ethernet 2
Local
Remote
C op pe rL in k 21 d E
R ug ge dize
73
R th ern et E xte nd er
Line
Power
5V
; 0.6A
Ethernet
2 1
Figure 7.
Model 2173R front panel
Table 2:
Front panel LED description
LED Status Description
Power
Green
Off
The device is powered on.
The device is powered off.
CopperLink
Green The port is connected.
Blinking Green Data transceiving.
Ethernet
Off
Green
*
Blinking Green
No valid link on this port.
The port is connected.
Data transceiving.
Local
Remote
Green
Off
Green
Off
The device acts in Local mode.
Local mode is off.
The device acts in Remote mode.
Remote mode is off.
*.
Once the unit connects to a power source, the Link LED will blink as the 2173R automatically looks for the other unit in the pair.
15
APPENDIX A
SPECIFICATIONS
A.1 LAN CONNECTION
• Two shielded RJ-45, 10/100Base-T, IEEE 802.3 Ethernet
• CopperLINK Connection: Shielded RJ-45
A.2 TRANSMISSION LINE
Two-wire unconditioned twisted pair.
A.3 COPPERLINK LINE RATE AND COPPERLINK DISTANCE
• Line Rate: Up to 155 Mbps aggregate (upstream/downstream) via
Auto Rate; and 25/25 Mbps via DIP switch settings.
• Distance: Up to 5,500 ft (1.6 km)
Note
Distances depend on line rate and line conditions.
A.4 LED STATUS INDICATORS
• Power (Green)
• CopperLINK: Link (Green)
• Ethernet: Link (Green) & Activity (Flashing Green)
• Remote (Green)
• Local (Green)
A.5 POWER SUPPLY
External AC and DC options:
• AC: 120 VAC, 220 VAC, and UI (120–240 VAC)
• DC: 12 VDC, 24 VDC and 48 VDC
• Power consumption: 860mA at 5V
A.6 TEMPERATURE RANGE
-40 to 85°C
A.7 HUMIDITY
Standard
:Up to 90% non-condensing
A.8 DIMENSIONS
1.5H x 4.13W x 3.75D in.(3.81H x 10.5W x 9.53D cm)
16
APPENDIX B
MODEL 2173R FACTORY
REPLACEMENT PARTS AND ACCESSORIES
Patton Model #
Base Models
2173R/E
Description
2173R/E-2PK
2173R/EUI-2PK
07M2173R-UM
Power Supplies
08055DCUI
08055-120-5-1
12V-PSM
24V-PSM
48V-PSM
Power Cords*
0805US
0805EUR
0805UK
0805AUS
0805DEN
0805FR
0805IN
0805IS
0805JAP
0805SW
CopperLINK Multi Rate 100 Mbps Ethernet Extender;
No power supply
CopperLINK Multi Rate 100 Mbps Ethernet Extender Kit (2 units preset to local and remote); No power supply
CopperLINK Multi Rate 100 Mbps Ethernet Extender Kit (2 units preset to local and remote); 110-240VAC
User Manual
100-240VAC (+5V reg. DC/2A) Universal Input Adapter.
120 VAC (+5V reg. DC/1A) Input Adapter
12 VDC Input Adapter
24 VDC Input Adapter
48 VDC Input Adapter
American Power Cord
European Power Cord CEE 7
United Kingdom Power Cord
Australian Power Cord
Denmark Power Cord
France/Belgium Power Cord
India Power Cord
Israel Power Cord
Japan Power Cord
Switzerland Power Cord
*Only required with optional UI power supply (08055DCUI)
17
APPENDIX C
MODEL 2173R INTERFACE PIN ASSIGNMENT
C.1 10/100BASE-T INTERFACE
RJ-45
• Pin 1: TX+
• Pin 2: TX-
• Pin 3: RX+
• Pin 6: RX-
• Pins 4, 5, 7, 8: no connection
C.2 COPPERLINK INTERFACE
RJ-45
• Pin 4: RING
• Pin 5: TIP
• Pins 1, 2, 3, 6, 7, 8: no connection
18
APPENDIX D
SAMPLE RATES/DISTANCE CHART, BASED ON 24 AWG (0.5 MM)
Rate Mode
Distance in
Feet (km)
4/1
4/1
100/70
100/70
25/25
*
50/50
50/50
70/70
70/70
Fast
Interleave
Fast
Interleave
Interleave
Fast
Interleave
Fast
Interleave
5,500
(1.6 km)
5,500
(1.6 km)
500 ft
(0.15 km)
250
(0.07 km)
2,250
(0.6 km)
1,750
(0.5 km)
1,750
(0.5 km)
1,750
(0.5 km)
1,750
(0.5 km)
*. For the 25/25 rate, set S1-3 to the OFF position.
Throughput at Max
Distance
(megabits per second)
4.00 (DS)
1.00 (US)
4.00 (DS)
1.00 (US)
83 (DS)
69.5 (US)
83 (DS)
69.5 (US)
24.89 (DS)
24.89 (US)
49.78 (DS)
49.78 (US)
49.78 (DS)
49.78 (US)
51 (DS)
51 (US)
51 (DS)
51 (US)
Note
The actual distance and link performance may vary depending on the environment and type/gauge of wire used.
Note
DS = downstream, US = upstream
19
Copyright © 2012
Patton Electronics Company
All Rights Reserved.
20
advertisement
Frequently Answers and Questions
What is the distance limit for copper link at 10Mbps?
What is this Patton device intended for?
What are the temperature and humidity range for the device to operate?
Does this device have warranty?
What are the safety precautions to follow when working with this device?
Related manuals
advertisement
Table of contents
- 4 Warranty Information
- 4 Compliance
- 4 EMC Compliance
- 4 Low-Voltage Direcive (Safety)
- 4 Radio and TV Interference (FCC Part 15)
- 5 CE Declaration of Conformity
- 5 Authorized European Representative
- 5 Service
- 6 Safety When Working With Electricity
- 8 General Information
- 8 Features
- 8 Description
- 9 Installation
- 10 Connecting the Twisted-Pair Line Interface
- 11 Connecting the 10/100Base-T Ethernet Interface
- 12 Connecting Power
- 12 Configuration
- 12 Configuring the hardware DIP switches
- 14 Configuring DIP Switch S
- 14 Operation
- 14 Power Up
- 15 Front Panel LED Status Monitors
- 16 Specifications
- 16 LAN Connection
- 16 Transmission Line
- 16 CopperLINK Line Rate and CopperLINK Distance
- 16 LED Status Indicators
- 16 Power Supply
- 16 Temperature Range
- 16 Humidity
- 16 Dimensions
- 17 Replacement Parts and Accessories
- 18 Model 2173R Interface Pin Assignment
- 18 10/100Base-T Interface
- 18 CopperLINK Interface