null  User manual
farnell.com
element14.com
2913
Process Control, Timers & Counters
Process Control
Analogue Signal Conditioners . . . . . . . . . . . .
Current and Voltage Controls . . . . . . . . . . . . .
Energy - Meters . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid Level Controllers . . . . . . . . . . . . . . . . . . .
Frequency Converter. . . . . . . . . . . . . . . . . . . . .
LED Process Indicators . . . . . . . . . . . . . . . . . .
Lighting Controller . . . . . . . . . . . . . . . . . . . . . . .
Speed Controller. . . . . . . . . . . . . . . . . . . . . . . . .
Process Relays . . . . . . . . . . . . . . . . . . . . . . . . . .
Process Timers . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial Converter . . . . . . . . . . . . . . . . . . . . . . . . .
Shaft Rotation Sensing Relay . . . . . . . . . . . . .
Tachometer Relays . . . . . . . . . . . . . . . . . . . . . .
Temperature Control Relays . . . . . . . . . . . . . .
Temperature/Process Controllers . . . . . . . . .
Page
Page
Touch Panel Screen . . . . . . . . . . . . . . . . . . . . . .
2934
Universal/’SMART’ Indicator . . . . . . . . . . . . . .
2926
Valve Control Module . . . . . . . . . . . . . . . . . . . .
2933 Timers & Counters
2923
Counter and Elapsed
2925
Hour Counter Modules . . . . . . . . . . . . . . . . . . .
2922
Electromechanical Counters . . . . . . . . . . . . . .
2925
Electromechanical Elapsed Hour Counters.
2924
Electromechanical Timers . . . . . . . . . . . . . . . .
2934
Electronic Counters . . . . . . . . . . . . . . . . . . . . . .
2934
Electronic Elapsed Hour Counters. . . . . . . . .
2925
Electronic Indicators . . . . . . . . . . . . . . . . . . . . .
2925
Electronic Timer/Counter . . . . . . . . . . . . . . . . .
2924
Electronic Timers . . . . . . . . . . . . . . . . . . . . . . . .
2931
Multirange Electronic Timers . . . . . . . . . . . . .
2913
Tally Counters . . . . . . . . . . . . . . . . . . . . . . . . . . .
2922
2923
2924
Automation
Temperature/Process Controllers
2953
2953
2952
2951
2955
2953
2957
2956
2940
2942
2953
Plastics Controller
6600 Series - 1/16 DIN
Refrigeration Controller
PJ easy Compact Series
These devices are designed specifically for
the management of refrigerated units, display
cases and chilled showcases where available
space is limited.
The depth of the units is only 31mm behind
the front panel. The Monitor version has no
output control while the Controller model has
a 16A relay compressor control output.
H=36, W=81, D(OA)=78mm
Ì
Ì
Ì
Ì
Only 31mm depth behind panel
IP65 protection
Fast set up using preset configuration
Scale range -10 to +50°C
539583
PID or On-Off control
Heat / Cool operation
Process and Heater alarms
Current "Quick Transfer"
RS485 communications slot
Soft start
Ramping set-point
Current display
Thermocouple input
SPDT Relay output - 2A @ 240V ac
CE Approved and UL Recognised
40
This instrument provides control in applications requiring a heater break function or soft
start for process warm up. Heater current can also be displayed, removing the need for a
separate ammeter.
The control types available are: Full PID with Pre-tuning, Self-tune, Manual tuning or On-Off
control.
541773
Price Each
Output Type
Mftrs. List No.
Order Code
PJEZMNN0E0
173-4645●
PJEZSNP000
173-4646●
Mftrs.
1+
Monitor
Controller
1 X Relay (Compressor)
Ì NTC Thermistor inputs
Ì 3 NTC Inputs for Control, Defrost and Probe3/
DI
Ì 230V ac power supply
Ì Built in alarm buzzer
Ì Front panel mounting
Ì IP65 protection
Ì Serial data output
Ì Fast set up using preset configuration
Ì Scale range -10 to +50°C
These devices are designed specifically for the management of refrigerated units, display
cases and chilled showcases. Versions are available with 1, 2 and 3 relay outputs and
have preset configurations for the following applications:
173-4648 - 3 input monitor
173-4649 - 1 Relay output, for use with static refrigeration units (No evaporator fan) and a
single NTC sensor input
173-4650 - 2 Relay outputs, for use on static units with active defrost by heater and control and defrost NTC sensor inputs
173-4651 - 3 Relay outputs, for use on ventilated units (Compressor, Fan and Defrost
control). 2 NTC input probes and a 3rd NTC probe
539586
Price Each
Mftrs. List No.
Order Code
PJEZM0N010
173-4648●
PJEZS0P000
PJEZY0H000
PJEZC0P000
173-4649●
173-4650●
173-4651●
List No.
100-240VAC
N6600Z2100-00
Order Code
1+
174-0299
1/16 DIN - PID
Refrigeration Controller
Output Type
Power Supply
Temperature and Process Controller
PJ easy Series
H = 36, W = 81, D(OA) = 78mm
Price Each
1+
Ì
Ì
Ì
Ì
Ì
Ì
Ì
H = 48, W = 48, D = 70mm Ì
Universal Input - Thermocouple, RTD and linear DC
Full PID with auto/manual pre-tune
Heat or Heat/Cool operation
Up to 3 outputs - Relay, SSR Driver and linear DC
Programmer function
Alarms and Diagnostics
Only 70mm depth behind panel
CE Approvals
Programmer Functions
Ì 2 programs of up to 16 segments
Ì Delay timer
Ì Auto holdback function - guaranteed soak
Ì Ramp, dwell, step, events, loop
Ì Function button for profiler control (run, hold, stop, reset)
Process Control, Timers & Counters
Ì Monitor with 1 NTC control input
Ì Controller has a Control NTC input
and a Defrost NTC input
Ì 230V ac supply
Ì Front panel mounting system
H=48, W=48, D=120,
Panel cut-out 45 x 45mm
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
This controller has a reduced behind panel depth of 70mm and capability expected from
higher end products. This includes a universal input for all sensor types allowing flexible
utilisation, 2 or 3 outputs (including relay, SSR driver, linear DC), full PID control and a
simple user interface with easy to read LED display consisting of 4 digits upper and lower,
4 button membrane keypad including function button that can be configured for auto/
manual, tuning or profiler control and 3 output status LED’s.
A programmer function has the capability of 2 profiles of up to 16 segments incorporating
delay timer, auto holdback for guaranteed dwell and easy control via the controller’s function button providing easy implementation of temperature profile control. Furthermore,
alarms and diagnostics help to prevent problems before they happen: relay life, high ambient warning and absolute or deviation limit alarms allow preventative maintenance actions
to be taken instead of needing emergency replacements should a controller fail.
Monitor
Controllers
1 X Relay
2 X Relay
3 X Relay
2913
2914
farnell.com
Temperature/Process Controllers continued
element14.com
Temperature Controller
IR33 Series
Temperature and Process Controller - continued
1/16 DIN - PID - continued
600369
Price Each
Supply Voltage
Mftrs. List No.
Order Code
Relay - Outputs 1 & 2
100 to 240VAC ac
E6C0RR002
179-1025
20 to 48VAC ac
E6C0RR022
179-1026
E6C0SR002
E6C0SR022
179-1027
179-1028
E6C0RRR02
E6C0RRR22
179-1029
179-1030
1+
H = 34, W = 76, D = 56mm
Ì IP65 protection
Ì 12 - 24V ac, 12 - 30V dc supply voltage
The IR33 series temperature controllers have all of the functions of the IR32 series with extra features such as PID autotune control. The program parameters are identical to the
IR32 so the IR33 can be used as like for like replacement for an IR32..
All types have two sensor inputs, selecteable bewteen NTC, PTC and PT1000, ideal for operation over the range -50 to +150°C
For ease of setup, the unit can be programmed via a PC, IR hand held programmer.
SSR & Relay - Outputs 1 & 2
100 to 240VAC ac
20 to 48VAC ac
Relay - Outputs 1, 2 & 3
100 to 240VAC ac
20 to 48VAC ac
539343
Price Each
SSR, Relay & Relay - Outputs 1, 2 & 3
100 to 240VAC ac
20 to 48VAC ac
E6C0SRR02
E6C0SRR22
179-1031
179-1032
Relay, Relay & Linear DC - Outputs 1, 2 & 3
100 to 240VAC ac
Output Type
Mftrs. List No.
Order Code
Controllers
1 X Relay
IR33V7LR20
173-4638●
IR33W7LR20
IR33Z7LR20
173-4639●
173-4640●
IRTRUES000
173-4642●
E6C0SSR02
179-1033
2 X Relay
4 X Relay
E6C0RRL02
179-1034
Accessories
Relay - Outputs 1, 2 & 3
100 to 240V ac
Remote Control (IR hand held prgrammer)
Automation
Multifunction Counter
1+
PJ32 On/Off Temperature Controller
1/16 DIN - tico 772
Ì
Ì
Ì
Ì
Ì
Ì
The tico 772 combines the functions of a preset, batch
and shift-counter, tachometer and timer. Normal totalizing
with presets, time and speed measuring is possible using
the 4 big tactile push button switches located beneath the
large coloured display. Two display versions are available,
utalising either LCD reflective or LCD transmissive technology.
1 or 2 NTC or PTC input options
1 or 2 independent controllers
Up to 3 relay outputs
230V ac power supply
Front panel mounting system
Plug in terminals
H = 48, W = 48, D = 112mm
Panel cut-out = 45 X 45mm
40
Process Control, Timers & Counters
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Supply Voltage
Power Drain
Large 2 line display for easy reading
Easy to operate with only 4 large keys
Plain text menus
Signal duration up to 10 minutes to provide improved control
High input frequency of up to 60 kHz
Increased accuracy by the use of 4th decimal place
Single or 2 relay output options
O/P Relay contacts 250V ac / 30V dc @ 5A
Quick installation by use of pluggable connection terminals
605589
Colour
Supply
Output
Mftrs.
Price Each
Background Digits
Voltage
Relays
List No.
Order Code
Reflective LCD
Reflective Black
230V ac
2
0772132
181-4469●
Transmissive LCD
Black
White
24V dc
2
0772302
181-4474●
1+
24VAC/dc
J, K, T, R, S, C, E, B, N, U, W and Plantinel thermocouples, PT100 2/3 wire, -5 to
56mV, 0 to 10V, 0 to 20mA
Sensor Options
NTC or PTC
Accuracy
NTC ±1°C
PTC ±3°C
Outputs
V6E: 8A SPCO relay
V6P, V0P: 16A SPCO relay
W0, W1: 1 SPCO 8A and 1SPST 8A relays
Z0, Z6: 1SPST 8A and 2 SPST 5A relays
Approvals
Conforms to CE generic standards
EN50081-1 and EN50082-1 for emc
and EN61010-1 for low voltage
Ambient Temperature -10 to 50°C, <85% RH non-condensing
Weight
150g
Range
Inputs
Outputs
Mftrs. List No.
Order Code
-50 to 150°C
1 PTC
8A
PJ32V6E000
130-0211
-50 to 150°C
2 PTC
16A
PJ32V6P000
130-0212
-50 to 90°C
2 NTC
16A
PJ32V0P000
130-0215
-50 to 90°C
2 NTC
8A/8A
PJ32W00000
130-0216
450126
PID500 Temperature Controller
Mftrs.
Ì Dual display of set point and process value
Ì On demand autotuning of PID parameters
Ì Programmable thermocouple, PT100, 1mV, 0-10V
or 0-20mA inputs
Ì 2 output type, relay or SSR
Ì 1 or 2 on/off or PID control outputs + alarms
Ì Sensor break detection & error compensation
Supply Voltage24VAC/dc
or
85 to 270VAC
Inputs
Thermocouple or PT100
Outputs 1-2 5A @ 240 V ac NO relay or
18V dc 20 mA SSR drive
Output 1
Optional 0/ 4-20mA, 0-10V or 0-5V
Control Action PID (autotune) or On/Off
Price Each
List No.
Order Code
Temperature Controllers
PJ32V6E000
130-0211●
PJ32V6P000
PJ32V0P000
PJ32W00000
130-0212●
130-0215●
130-0216●
Voltage
24VAC/dc
24VAC/dc
85 to 270VAC
85 to 270VAC
Outputs
Price Each
1/2
List No.
Order Code
Relay / Relay
SSR / Relay
Relay / Relay
SSR / Relay
PID500ML-0000
PID500ML-1000
PID500MH-0000
PID500MH-1000
130-0199●
130-0201●
130-0200●
130-0202●
1+
5+
10+
Ì Dual display of set point and process value
Ì On demand autotuning of PID parameters
Ì Programmable thermocouple, PT100, mV, 0-10V or 020mA inputs
Ì NO Relay outputs, 5A @ 240V ac
Ì SSR Drive outputs, 20mA @ 18V dc
Ì 1 or 2 on / off or PID control outputs + alarm
Ì Single point ramp-soak algorithm
Ì Sensor break detection and error compensation
Outputs 1&2 Forward or Reverse action
Outputs 2&3 Absolute or Deviation alarm
Accuracy
Greater of ±0.25% FS or ±1°C
Ambient Tem- 0 to 50°C, 85% RH non-condensing
perature
Weight
195g
Mftrs.
5+
1/4 DIN - PID330
450120
Operating
1+
PID Temperature Controller
H = 48, W = 48, D = 94mm (behind panel)
Panel cut-out = 45 x 45mm
2914
Ì Simple programming of up to 4 relay or
1 SSR outputs
Ì 9 pre-set control modes
Ì On / Off or PID autotune control
Ì IR receiver and buzzer fitted as standard
Ì IR Remote Control and Programming
Keys available seperately
Ì Selectable NTC / PTC / PT1000 sensor
input options
10+
H = 96, W = 96, D = 74.5mm
539341
Supply
Outputs
Mftrs.
Voltage
Voltage
List No.
85 - 270VAC/dc
85 - 270V ac/dc
2 x Relay
3 x Relay
PID330MH-0000
PID330MH-0001
Price Each
Order Code
130-0204●
173-4637●
1+
farnell.com
Control
Alarm
Memory backup
Operating temperature
Storage temperature
UMT 500 Multiple Digital Timer
Ì
Ì
Ì
Ì
Ì
Ì
5 independent timers or relays
5 programmable timer modes
3 timing ranges
External start or reset
Large clear LED display with status indicators
Security coded program access
element14.com
2915
SPCO, 3A @ 240Vac/30Vdc
NO, 500mA @ 120Vac
Lithium battery, 5 years in storage, 10 years working
0°C to +50°C
-20°C to + 85°C
204844
Price Each
Supply Voltage
Mftrs. List No.
Order Code
Platinum Resistance (PT100)
240V ac
DTC41002240VAC
1+
5+
10+
25+
275-300
Thermocouple
Timing Ranges
Timing Modes
110V ac
240V ac
0 to 999.9 Secs, 0 to 99 mins 59 secs, 0 to 99 hrs 59 mins
DE = delay on energise
INT= interval
DD= delay on de-energise
CCT= cycle timer with cycle limiter
DODO= delay on/delay off
RLY= externally activated relay
24VAC/dc
110 to 230VAC
3VA max.
OP 1&2: SPDT relay 5A @ 240V ac resistive
OP 3-5: SPST relay 5A @ 240V ac resistive
100ms
0 to 50°C
Complies with CE directives EN50081-1
& EN50082-1 for emc and EN61010-1 for low voltage.
290g
Supply Voltage
Power Drain
Output Ratings
Reset Time
Operating Temperature
Approvals
Weight
Price Each
Order Code
UMT500-ML
UMT500-MH
130-0207●
130-0208●
1+
5+
10+
Common Features:
Ì Structured operating and programming layout
Ì Freely configurable process value input
Ì Two setpoints
Ì One binary input
Ì Two switching outputs
On/Off Control - ‘E5C’
Setting accuracy
Output contact
Contact rating
±2%
SPCO
3A @ 240V ac (res.)
Operating voltages
Operating voltage range
Temperature Range
0°C to 400°C
Scale Division
2°C
0°C to 200°C, 0°C to 400°C
5°C
Platinum resistance input sensor:
Type K thermocouple sensor:
110V ac,240V ac 50/60HZ
85% to110%
204820
Temperature
Operating
Range
Voltage
Order Code
0°C to 100°C
0°C to 200°C
0°C to 400°C
240V ac
240V ac
110V ac
170-914
175-521
175-523
Sockets
DIN rail/surface
Chassis
Price Each
1+
5+
10+
25+
330-954●
118-1272●
Digital Temperature Controller
Multirange and Input Digital, On/Off
Ì Two types, one has thermocouple inputs, the other
PT100 inputs
Ì Temperature scale ranges from -99°C to +999°C
Ì Programmable alarm output functions
Ì Other programmable features include:- °C or °F hysteresis (level 1 to 9), control action, reset & password
to prevent tampering
Ì Each unit is entered with preset parameters to enable
sensible operation on initial connection to supply
Ì Suitable for panel or DIN rail mounting
Ì
Ì
Ì
Ì
Proven self-tuning facility
Ramp function °Cmin or °C/h
Key/level inhibit
Front protection IP65 / rear IP20
Process Valve Input:
For Pt100, Pt1000, KTY11-6 resistance thermometers
Type L, J, U, T, K, N, S, R, B thermocouples
Current 0 - 20mA, 4 - 20mA
Voltage 0 - 10V, 2 - 10V
Binary Input:
Via floating contact
On type 702042/43/44: always,
On type 702040/41: configurable as an alternative to output 2
Output 1:
Relay, make (SPST-NO), contact rating 3A/250V AC with resistive load
2-state controller (inverse/direct) or 3-state controller (inverse/direct) or limit comparator
functions (lk 1 - 8) can be configured
Output 2:
On Type 702042/43/44: relay, make (SPST-NO), contact rating 3A/250 V AC with resistive
load, and in parallel: logic 0/5 V/20 mA, Rload 250Ω on Type 702040/41: logic 0/5V 20
mA, Rload 250Ω configurable as an alternative to binary input
2-state controller (inverse/direct) or 3-state controller (inverse/direct) or limit comparator
functions (lk 1 - 8) can be configured
General Controller Data:
Measuring Circuit Monitoring
Data Backup
Supply Voltage
Power Drawn
Electrical Connection
Ambient/Storage Temperature
Dimensions by Type
Housing Dimensions
Depth Behind Panel
panel Cut-Out
the outputs adopt a defined status
EEPROM
110 to 240 V AC @ 48/63 Hz
Max. 5 VA
At the back, via pluggable screw terminals
0 to 55 °C/ -40 to 70 °C
702040 702041 702042 702043 702044
48 x 24 48 x 48 48 x 96 (hoch) 96 x 48 (quer)
100 100 70 70 70
45x22,2 45 x 45 45 x 92 92 x 45 92 x 92
96 x 96
Accessories
Mounting frame for controller on DIN rail
4724100 - 48x48mm
4724112 - 48x96mm (Portrait)
4724124 - 96x48mm (Landscape)
40
Process Control, Timers & Counters
Ì Temperature controllers for On/Off control via type K &
PT100 sensors
Ì Operation of output relay and LED indicator occurs simultaneously with power supply connection
Ì When preset temperature is achieved, cooling cycle commences by reset of output relay and LED indicator is extinguished
Ì If thermocouple opens circuits, controller automatically enters safer cooling mode
Ì Controllers are cold junction compensated. Panel mounting
bracket supplied
H=48, W=48, D=85.8,
Panel cut-out=45x45
Freely programmable compact controller series with five different models. Depending on
the version, 10 or 20mm high 7-segment display for indicating process values and setpoints, or for dialogs. The instruments are configured from just 3 keys. The parameter setting is arranged dynamically, and after two seconds without any operation, the value is accepted automatically. All the usual input signals and controller structures can be programmed.
Automation
List No.
275-268
275-270
iTRON Microprocessor Controller Series
450130
Mftrs.
DTC41001110VAC
DTC41001240VAC
333877
Price Each
Type
Format
702040/...
702041/...
702043/...
702044/...
48 x 24mm
48 x 48mm
96 x 48mm (quer)
96 x 96mm
Order Code
1+
5+
10+
472-4136
472-4148
472-4161
472-4173
H=48, W=48, D=89 (behind panel)
Panel cut-out=45x45.
Supply voltage
Power consumption
24V ac/dc types
110V/240V ac types
Sensor type
Model 01
Model 02
Temperature ranges
PT100 types
Thermocouple types
Display
Offset accuracy
Histeresis
Output rating
110V ac or 240V ac, ±10%, 50/60Hz
60mA
1.5VA
J, K, T and N Thermocouples
PT100 (DIN) Platinum resistance sensors
-99°C to +400°C
J = -99°C to +700°C, K and N = -99°C to + 999°C, T = -99°C to +300°C
Three digit, seven segment LCD plus indicators for Fahrenheit and output.
Thermocouple ±5°C PT100 ±2°C
1 to 9 degrees
INTELLIGENT ONLINE BUYING
SYSTEM PROVIDING
Complete cost control, reduced
administration time, visibility of your
spend, flexibility and personalised to
your company’s needs.
farnell.com/ibuy
2915
2916
farnell.com
Thermo
Temperature/Process Controllers continued
ZEN Programmable Relay
Ì Highest control performance
Ì Improved visibility and high reliability
Ì Depth beyond front panel: 60 mm
Ì Faster sampling at 250 ms
Ì Ideal for heater control
Ì Approvals: UL 61010-1, CSA C22.2 No. 1010-1,
EN61326, EN61010-1, IEC61010-1 and VDE0106
Power 3.5 VA (100 to 240 VAC) Setting method Digital setting using front panel keys
3.5 VA (24 VAC)
Control method ON/OFF control or 2-PID control (with auto-tuning)
2.5 W (24 VDC)
Indication method 7-segment digital display and individual indicators
Operating temperature
Operating humidity
Operating voltage range
Inputs
Supply
couple
Mftrs.
Voltage
Type
List No.
12V/dc
24VAC/dc
230VAC/dc
Automation
Input, outputs
List No.
Order Code
ZEN-10C1AR-A-V2
ZEN-10C1DR-D-V2
ZEN-20C1AR-A-V2
ZEN-20C1DR-D-V2
197-3919
197-3920
197-3921
197-3922
ZEN-BAT01
ZEN-KIT01-EV4 ( AC )
ZEN-KIT02-EV4 ( DC )
ZEN-ME01
ZEN-PA03024
ZEN-SOFT01-V4
ZEN-CIF01
197-3923●
197-3924
197-3925
197-3926
197-3928
197-3929
197-3930
Programmable Relays
6 inputs, 4 outputs
6 inputs, 4 outputs
12 inputs, 8 outputs
12 inputs, 8 outputs
Relay Accessories
Batteries for ZEN relay
ZEN relay starter kit, AC
ZEN relay starter kit, DC
Memory cassette, EEPROM
PSU for ZEN relay
Software for ZEN relay
Cable 2m, ZEN relay to PC
3+
5+
Ì
Ì
Ì
Ì
Ì
Voltage
Process Control, Timers & Counters
0 to 50°C/-25 to 70°CC (with no icing)
3 VA Max.
0°C to +600°C°C
±0.5% (of full scale) ±1 digit
3 digits, 14mm, 7 parts red LED
77x34x70mm
List No.
List No.
Price Each
Order Code
1+
5+
10+
25+
230VAC
ETC1311-FE-2307 125-0481●
9 - 30VDC SMPS ETC1311-FE-SM7 125-0482●
EDT1411 NTC Thermostats
33x77mm sized
On-Off control
Single contact output
Single contact output for cooling control
NTC probe input for cold temperature
Offset value can be entered for NTC
probe
Ì Compressor protection parameters can
Ì
Ì
Ì
Ì
Ì
Ì
be entered
In case of probe failure, output state can be selected On or Off or Periodical running
Upper and lower limits of the setpoint can be adjusted
16 different warning tones
Upper and lower limits of the alarm value can be adjusted depending on setpoint value
CE marked according to European Norms
Ambient/Storage Temperature
Power Consumption
Scale
Accuracy
Indicator
Output
Hysteresis
Dimensions (WxHxD)
Price Each
Order Code
1+
5+
10+
25+
EDT1423-NTC-2307 125-0492●
Accessories
NTC Thermoplas- E-NTC-APT-1.5T7
tic Probe
NTC Plastic Probe E-NTC-APP-1.5P7
125-0501●
125-0502●
Temperature display CUB5
Ì 5-digit 7-segment display
with 12,2 mm LCD or
backlit LCD
Ì Input RTD or thermocouples
Ì Optional relay and serial output module
Ì Easy programming via buttons or software
Ì Sensor fail detection and programmable offset
Ì NEMA4X/IP65 sealed front bezel
Inputs
449935
Voltage
0 to 50°C/-25 to 70°C (with no icing)
7 VA Max.
-50°C to +100°C°C
± 1°C
250VAC, 8A
Adjustable between 0 and 20°C
85x34x70mm
Mftrs.
Ì Set value can be adjusted by using single key
Ì CE marked according to European Norms
Mftrs.
125-0501●
125-0502●
449948
33x77mm sized
On-Off control
J type thermocouple
Temperature compensation
In the case of probe failure, heating
can be selected on, off or periodical
running
Ì Upper and lower limits of the setpoint
can be adjusted
Ì
Ì
Ì
Ì
Ì
0 to 50°C/-25 to 70°CC (with no icing)
3 VA Max.
-50°C to +110°C°C
0.1°C/± 1°C
4 digits, 12mm, 7 part yellow LED
250VAC, 8A
Adjustable between 0.1 and 20°C
85x34x70mm
2-, 3- or 4-wire RTD, Ni120, Cu10; Thermocouples type: S, T, J, N, K, E, R, B
or -10 to +65 mV
1 °C/F or 0,1 °C/F
Offset and decimal point
5-digit standard LCD
Peak/Valley memory
1 programmable input for contact
Relay output: Single FORM-C relay 1 amp @ 30 VDC resistive; 0,3 amp @ 125
VAC
Serial communication: RS485 multipoint balanced
RS232 half duplex
Baud rate from 300 to 19.200 baud
Programming
Programmable with two front buttons or with Software
Operating temperature
-35°C to +75°C depending from the display colour and intensity
Power supply
+9 to +28 VDC, 125 mA max. or 85-250 VAC 50/60 Hz with additional power
supply module MLPS
Dimensions (W x H x D) 74,9 x 39,1 x 43,4 mm
Resolution
Scaling
Display
Special function
User input
Optional cards
509303
Price Each
Mftrs. List No. Function
CUB5RTR0
CUB5TCR0
Accessories
CUB5RLY0
CUB5COM1
CUB5COM2
MLPS1000
Display
Order Code
Temperature display for RTD Standard LCD
Temperature display for TC’s Standard LCD
158-2022●
158-2024●
Optional relay output card
Optional RS485 serial communication card
Optional RS232 serial communication card
Power supply 85-250 VAC
125-3412●
125-3413●
125-3415●
125-3417●
1+
5+
10+
Temperature display PAXT
449946
2916
E-NTC-APP-1.5P7
Supply
Ì
Ì
Ì
Ì
Ì
Supply
25+
E-NTC-APT-1.5T7
Ambient/Storage Temperature
Power Consumption
Scale
Accuracy
Output
Hysteresis
Dimensions (WxHxD)
ETC1311-FE Thermostats
Ambient/Storage Temperature
Power Consumption
Scale
Accuracy
Indicator
Dimensions (WxHxD)
10+
Ì 33x77mm sized
Ì On-Off control
Ì 3 contact outputs for cooling defrost and fan controls
Ì 2 probes for temperature and defrost controls
Ì Adjustable offset for probe
Ì The maximum and the minimum
values of the setpoint can be limited
Upper and lower alarm values can be entered depending on setpoint value
A buzzer warning for probe failure or alarm cases
Time and evaporator temperature dependent defrosting is possible
Fan may be operated depending on defrost and compressor
CE marked according to European Norms
230VAC/dc
40
5+
EDT1423 NTC Thermostats
Price Each
1+
1+
EDT1411-NTC-127 125-0487●
EDT1411-NTC-247 125-0488●
EDT1411-NTC-2307 125-0489●
NTC Thermoplastic
Probe
NTC Plastic Probe
642113
Mftrs.
Price Each
Order Code
Accessories
-10°C to +55°C
25% to 85%
85% to 110% of rated supply voltage
Thermocouple and Platinum resistance thermometer
No. of
element14.com
Ì 5-digit 7-segment display
with 14 mm LED
Ì Input RTD or thermocouples
Ì Option cards: 2 or 4 setpoints, analog output and
serial communication
Ì Easy programming by front buttons or software
Ì Sensor fail detection and offset
Ì NEMA4X/IP65 sealed front bezel
farnell.com
Input
2- or 3-wire RTD, Ni120; thermocouples type: S, T, J, N, K, E, R, B or
-10 to +65 mV
20 measurements per second
0,1 °C/F
Offset and decimalpoint, linearisation
5 buttons for programming/reset
Dimmable 5-digit LED with 14 mm digit height
Peak-/Valley memory, totalizer
3 inputs NPN- or PNP switching
2 Form C relays 5 A @ 120/240 VAC or 4 Form A relays 3 A @ 120/
230 VAC
RS485 or RS232
0/4 to 20 mA or 0 to 10 VDC programmable
85 to 250 VAC 50/60 Hz or 11 to 36 VDC
Robust plastic case, front IP65
Measurement rate
Resolution
Scaling
Front buttons
Display
Special functions
User inputs
Relay outputs (optional)
Serial communication (optional)
Analog output (optional)
Power supply
Housing
element14.com
On/Off and PD Control - TOS Range
2917
AUTONICS
Ì Low cost analogue on/off and PD controllers housed in flame retardant case
Ì PT100 or K Type thermocouple inputs.
Thermocouple versions include cold
junction compensation
Ì Have an LED indicator to show output
’ON’ and a large clear dial to show set
temperature
Ì Suitable for panel or DIN rail mounting
H=48, W=48, D=91 (behind panel=78),
Panel cut-out=45x45.
509328
Price Each
Mftrs. List No. Function
Supply
Order Code
PAXT0000
Temperature display
Accessories
85-250 VAC
158-2013●
PAXCDL10
PAXCDS10
PAXCDS20
Analog output card
Dual setpoint relay output card
Quad setpoint relay output card
1+
5+
10+
881-119
881-077
881-089
Supply voltage 110/240V ac @ 50/60Hz, ±10%
Power supply 3VA
Scale range
PT100
0°C to +100°C
Supply
Mftrs.
Price Each
Range
Voltage
List No.
Order Code
ON/OFF Temperature Controllers
Thermocouple and Platinum Resistance
Type K Thermocouple Controllers
0°C to +200°C
204915
Price Each
1+
5+
10+
Universal Electronic Controllers
Ì Temperature input or universal input
Ì Relay or SSR output versions
Ì 2 independent control loops
Ì Auto-tuning PID control
Ì Real time clock
Ì Infrared receiver and buzzer
Ì Plug-in terminals
25+
107-991
107-992
530-049
The IR33 universal electronic controllers replace the IR32 range, offering additional features such as auto-tuning PID control and real time clock for managing working cycles and
logging alarms. The universal versions can also accept PT100, J and K type thermocouples, DC Voltage and DC mA inputs.
The controllers feature a simple user interface, two independent control loops and are
housed in a compact panel mounting enclosure. All versions can be connected to a network for monitoring and programming, using an optional RS-485 serial interface. The IR33
controllers are powered from 12 to 24Vac/dc and optional transformers are available for
powering the controllers from 110Vac or 230Vac.
Input options
Operating range
On/Off and PD Control
Ì Housed in flame retardant DIN48 panel mounting plastic
case
Ì PT100 and Type K thermocouple types
Ì Power on & status LED indication. Facility to drive an external deviation meter on the standard 11 pin base connection
Ì Cold junction compensation and lead resistance compensation are provided
Ì Temperature setting is lockable using the hex key provided
H=48, W=48, D=100 (behind panel=87)
Panel cut-out=45x45
Supply voltage
Power consumption
Setting accuracy
Operating hysteresis
Output contact
110/240V ac + 10% -15%, Contact rating
5A 240V ac/30V dc
47-63Hz
4VA max
Cycle time (PD types) 20 s
±2% full scale
Proportional band (PD 0-20% full scale
types)
0.5% full scale
Output for external meter 50-0-50μA
SPCO
Operating temperature -10°C to +50°C
Accuracy
Supply voltage
Power consumption
Working temperature
NTC, NTC-HT, PTC, PT1000, PT100, J/K Type Thermocouples, DC Voltage, DC
Current
NTC -50 to 90°C; NTC-HT -40 to 150°C; PTC -50 to 150°C; PT1000 -50 to
150°C, -199 to 800°C;
PT100 -199 to 800°C; DC Voltage 0-1V, -0.5 to +1.3V, 0-10V, 0-5V ratiometric;
DC Current 0-20mA, 4-20mA
±0.5% of max. range
24VAC/DC
3VA
-10°C to 55°C
659097
Price Each
Output
Mftrs. List No.
Order Code
1 Relay
2 Relay
4 Relay
4 SSR
IR33V9MR20
IR33W9MR20
IR33Z9MR20
IR33A9MR20
210-0007●
210-0008●
210-0011●
210-0012●
Mftrs.
Sensor
List No.
On/Off Controller
-50° to +150°C
Order Code
Pt100
TC4810-51 177-180
0° to +100°C
0° to +200°C
0° to +400°C
0° to +800°C
Pt100
TC4810-52
Thermocouple Type KTC4810-01
Thermocouple Type KTC4810-02
Thermocouple Type KTC4810-04
177-181
177-182
177-183
177-184
PD Controller
0° to +100°C
0° to +200°C
0° to +400°C
Pt100
TC4830-52 177-186
Thermocouple Type KTC4830-01 177-187
Thermocouple Type KTC4830-02 177-188
1+
5+
5+
10+
Humidity & Air Pressure (Process)
Price Each
Range
1+
40
ON/OFF, P or PI Control -Infra-Red
204821
Temperature
275-347
Process Control, Timers & Counters
Mftrs. List No. 4801 J=107-991, 4801 K=107-992, 4801 T=107-993, 4804 A=530049
Order Code
10+
Temperature Controller
H=34.2, W=76.2, D=101
Panel cut-out = 71 x 29
Note: PT100 instrument is suitable for installation with 2 or 4 wire sensor only
Type J thermocouple
Type K thermocouple
PT100 platinum resistance
5+
275-323
110/240V ac TOS-B4RK2C
H=48, W=96, D=68.1, Panel cut-out=92x45
J: -50°C to +625°C (-60°F to +1160°F)
K: -50°C to +700°C (-60°F to +1300°F)
T: -50°C to +350°C (-60°F to +660°F)
PT100: -99.9°C to +199.9°C (-99.9°F to +199.9°F)
J, K, T: 1°, PT100: 0.1°
5A @ 250V ac/30V dc
115/230V, ±15%
0°C to +45°C
1+
Automation
Ì Large 11.2mm 31⁄2 digit LED display
Ì Standard 96x48mm DIN case
Ì Slimline design, depth behind panel only
63mm
Ì Quick-release plug-in rear terminals
Ì SPCO relay contact switches at set point
adjustable by front panel potentiometer
Ì Thermocouple instruments have automatic cold junction compensation
Resolution
Contact rating (resistive)
Operating voltage
Ambient operating temperature
0°C to +100°C or 0°C to +200°C
SPCO, 3A @ 240V
±2%
0.5% of span
204845
Temperature
Platinum Resistance Controllers (PT100)
0°C to +100°C
110/240V ac TOS-B4RP1C
Temperature range
Thermocouple
Output rating
Accuracy
Hysteresis
10+
H=33, W=75, D=64,
Panel cut-out=71 x 29
Controllers
Ì Digital green LED display, sealed to IP65
Ì Programming functions include:- set-point limits,
alarm, status, offset and control action
Ì Built-in buzzer CE marked
Ì Can accept parameters via optional infra-red remote transmitter
Ì 12V ac/dc mains supply voltage can be provided
by optional transformers
Ì Scaleable input ranges
Ì Applications include:- environment chambers,
air-conditioning, driers, etc.
Infra-Red Remote Transmitter
Ì Once enabled, programmes several controllers rapidly. Requires 2xAA batteries
Ì Each controller has a unique code. Parameters can only be changed when code is
identified
Input options
0.5VDC or 1.0VDC
Operating range Scaleable -99 to +999
Resolution
0.1 or 1 unit, according to
display value (autoranging)
Accuracy
±0.5% of max. range
Supply voltage 12 - 24V ac/dc
Power consumption
Working temperature
Output configuration
940-033
940-045
Relay rating
3VA max
0 to 50C
1 x SPDT
I x SPDT + 1 x SPST relays
8A @ 250V ac max.
2917
2918
farnell.com
element14.com
Mftrs.
Temperature/Process Controllers continued
Supply Voltage
ON/OFF, P or PI Control -Infra-Red - continued
Humidity & Air Pressure (Process) - continued
Price Each
List No.
Order Code
Temperature Controllers
100-240Vac
320000
737-227
12Vac/dc
24Vac/dc
320040
320050
737-239
737-240
301.610
737-252
1+
5+
10+
25+
204749
Panel Adaptors
Price Each
Type
Mftrs. List No.
Humidity Controller
1 Relay
IR32V4L000
0.5VDC to +1.0VDC dc
Order Code
1+
5+
10+
25+
1/16 DIN
PID Control - ’9900 1/16 DIN’
940-033
Ì Industry standard format with 48x48mm
front fascia
Ì PID autotune on warm up or at set point
Ì Selectable inputs include 9 thermocouples
and 2 or 3 wire PT100
Ì Dual output, extra heavy duty relays for
alarms or heat/cool operation
Ì Bright clear green display configurable in
1.0/0.1 digit °C or °F
Air-Pressure (process) Controller
2 Relay
0-20mA/4-20mA
IR32V4L000
940-045
Transformers
240V ac to 12V ac/dc TRA12UN100
120V ac to 12V ac/dc TRA12UN111
Humidity Probe
DPWC110000
645-400
645-412
206-8621●
PID & Autotune and Data Logging Option
H=48, W=48, D=114
3300, 9300 & 9400 Series
H=48, W=48, D=102
Type 3
H=24, W=48, D=102
Type 1
Ì
Ì
Ì
Ì
6 alarm modes with loop break alarm
Zero and span adjustment for on site calibration
Matching 1⁄4" and 1⁄8" panel adaptors for retro fit replacement for larger units
Operator lockout prevents unauthorised access
Supply voltage
Outputs
Automation
40
Power Socket option
Temperature range
Sensor types
H=48, W=48, D=114 Type 2
Process Control, Timers & Counters
Ì PID autotune automatically matches PID setting to the application
Ì Bright LED 4 digit display configurable to °C/°F and engineering units
Ì RS232 and 485 options for communication to PC or PLC. CALgrafix, Order Code 4009460
Ì 2 colour display shows setpoint and process variable. 9400/9411 versions
Ì Ramp/Soak, for controlled warm up and timed temperature soak
Ì Selectable inputs, thermocouple, RTD/PT100 and linear process
Ì Dual output
Ì Heat/Cool operation.
Ì Zero and span adjustments for on site calibration
Ì Sleeve mounting for easy servicing and fitting communication board
Ì Positive feel buttons and helpful menus speed set-up
Ì Full CE compliance, IP66/NEMA4 fascia, UL Recognised, CSA approved
Supply voltage
Outputs
Temperature range
Sensor types
Linear input
Calibrated accuracy
Ambient conditions
110/240Vac ±10%, 50-60Hz 3VA
Relay 2A & 1A @ 250Vac, SSR Drive 10mA @>5V dc
User selectable between 0 to 50°C
Thermocouples, Type B, E, J, K, L, N, R, S, T & RTD/PT100
0 to 50mV
± 0.25% sensor maximum ± 1c
0 to 50°C
204769
Mftrs.
Type
1
1
2
3
3
Price Each
Outputs
List No.
Order Code
2A Relay & SSR
2A Relay & 1A Relay
2A Relay & SSR
2A Relay & SSR
2A Relay & 1A Relay
3300
3311
9300
9400
9411
565-118
565-120
565-131
565-167
565-179
1+
5+
10+
25+
Ì
Ì
Ì
Ì
Ì
Outputs
Temperature range
Sensor types
Linear input
Calibrated accuracy
Ambient conditions
Mftrs.
Price Each
Voltage
List No.
Order Code
1+
5+
10+
25+
SP1-Relay and SP2-Relay Outputs
230VAC
991.12C
737-276
115VAC
991.11C
737-288
SP1-SSR and SP2-Relay Outputs
230VAC
992.12C
737-290
115VAC
992.11C
737-306
SP1-SSR and SP2-SSR Outputs
230VAC
992.22C
737-331
Panel Adaptor
1/4 DIN
737-367
904.400
Temperature Controller
E5CB Series - 1⁄16 DIN
Operating temperature
Operating humidity
Operating voltage range
Inputs
Power
Setting method
Control method
Indication method
Highest control performance
Improved visibility and high reliability
Depth beyond front panel: 60 mm
Faster sampling at 250 ms
Ideal for heater control
Approvals: UL 61010-1, CSA C22.2 No. 1010-1,
EN61326, EN61010-1, IEC61010-1 and VDE0106
-10°C to +55°C
25% to 85%
85% to 110% of rated supply voltage
Thermocouple and Platinum resistance thermometer
3.5 VA (100 to 240 VAC)
3.5 VA (24 VAC)
2.5 W (24 VDC)
Digital setting using front panel keys
ON/OFF control or 2-PID control (with auto-tuning)
7-segment digital display and individual indicators
639465
Supply
Output
Voltage
100 to 240VAC
24VDC
100 to 240VAC
24VDC
100 to 240VAC
24VDC
100 to 240VAC
24VDC
100 to 240Vac ± 10%, 50-60Hz 3VA
12V or 24V ac/dc ±20%
Relay: 2A @ 250V AC (Resistive) SSR Drive: 10mA @ 5Vdc
User selectable between -200 to 1800°C
Thermocouples, Type B, E, J, K, N, R, S, T & RTD/PT100
-10 to 50mV
± 0.25% sensor maximum ± 1c
0 to 50°C
204741
2918
204736
Supply
H= 48mm, W= 48mm, D= 60mm
Ì Ultra compact,
sealed front fascia
(24x48mm) to NEMA 4X/IP66
Ì PID autotune, automatically matches PID settings to the
application
Ì Dual output, 2A relay &; SSR drive for
alarms or heat/cool operation
Ì Bright LED 4 digit display configurable
in °C, °F and engineering units
Selectable inputs include 9 thermocouples, RTD/PT100 and linear process
Zero and span adjustment for on site calibration
Matching 1/16 DIN panel adaptors for retro-fit replacement of 1/16 DIN units
Low supply voltage versions 12/24V ac/dc available
Operator lockout, three levels for operational security
Supply voltage
Linear input
Calibrated accuracy
Ambient conditions
Ì
Ì
Ì
Ì
Ì
Ì
PID Control - ’3200 1/32 DIN’.
H=24, W=48, D=102
Dual 115/230Vac ±15% 6VA
SP1 relay 16A de-rated to 5A for continuous switching or optional
SSR drive 10mA @ 5V dc
SP2 relay 8A de-rated to 3A for continuous switching or optional
SSR drive 10mA @ 5V dc
4-20mA 500ohm max
User selectable between -200 to 1800°C
Thermocouples, Type J, K, N, R, S, T, E, L, B & RTD/PT100 2 or 3
wire
0-20mV, 4-20mV
± 0.25% sensor maximum ± 1C
0 to 50°C
Mftrs.
List No.
Voltage (For driving SSR)
Voltage (For driving SSR)
Voltage (For driving SSR)
Voltage (For driving SSR)
Relay
Relay
Relay
Relay
E5CB-Q1P AC100-240
E5CB-Q1PD AC/DC24
E5CB-Q1TC AC100-240
E5CB-Q1TCD AC/DC24
E5CB-R1P AC100-240
E5CB-R1PD AC/DC24
E5CB-R1TC AC100-240
E5CB-R1TCD AC/DC24
Price Each
Order Code
197-3872
197-3874
197-3875
197-3876
197-3877
197-3878
197-3879
197-3880
1+
3+
5+
farnell.com
Digital Temperature Controllers
E5CN-H Series - 1⁄16 DIN
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
High Resolution display with 5 digits
Layed programming menues
High speed sampling cycle of 60 ms
High Accuracy - Thermocouple/PT input:± 0.1% of PV, Analog input:±0.1% FS
Flexible contact with logic operations
Preventive maintenance for relays
Option Units can be mounted to provide
additional functions
Complete with terminal cover
CE approved, UL Recognised
H = 48, W = 48, D = 78mm
535351
Supply
Mftrs.
Voltage
Output
List No.
Price Each
Order Code
1+
element14.com
2919
Ì One-touch operation with PF Key that can be assigned to auto manual, RUN/STOP, or
other functions.
Ì Complete with terminal cover
Ì Option Units can be mounted to provide additional functions
Ì CE approved, UL Recognised
535352
Supply
Mftrs.
Voltage
Output
Price Each
List No.
Order Code
1+
Controllers - 1⁄8 DIN
100 to 240VAC None fitted, 2 slots
E5EN-HAA2HBM-500
100 to 240VAC Relay
E5EN-R3HMT-500N
100 to 240VAC Current
E5EN-Q3HMT-500N
100 to 240VAC Voltage (For driving SSR) E5EN-C3MT-500N
100 to 240VAC Voltage (For driving SSR) E5EN-C3ML-500N
24V ac/dc
None fitted, 2 slots
E5EN-HAA2HBMD-500
24V ac/dc
Relay
E5EN-R3MTD-500N
24V ac/dc
Current
E5EN-Q3HMTD-500N
24V ac/dc
Voltage (For driving SSR) E5EN-C3MTD-500N
170-8039●
197-3856
197-3858
197-3860
197-3863
170-8045●
197-3857
197-3859
197-3862
Controllers - 1⁄4 DIN
Relay
E5CN-HR2M-500
170-8014●
100 to 240VAC
100 to 240VAC
100 to 240VAC
24V ac/dc
24V ac/dc
24V ac/dc
24V ac/dc
100 to 240VAC
24V ac/dc
100 to 240VAC
24V ac/dc
100 to 240VAC
24V ac/dc
100 to 240VAC
24V ac/dc
Voltage (For driving SSR)
Current
Linear Voltage
Relay
Voltage (For driving SSR)
Current
Linear Voltage
Relay
Relay
Voltage (For driving SSR)
Voltage (For driving SSR)
Current
Current
Current
Current
E5CN-HQ2M-500
E5CN-HC2M-500
E5CN-HV2M-500
E5CN-HR2MD-500
E5CN-HQ2MD-500
E5CN-HC2MD-500
E5CN-HV2MD-500
E5CN-R2MT-500
E5CN-R2MTD-500
E5CN-Q2MT-500
E5CN-Q2MTD-500
E5CN-C2MT-500
E5CN-C2MTD-500
E5CN-C2ML-500
E5CN-C2MLD-500
170-8015●
170-8017●
170-8018●
170-8019●
170-8020●
170-8021●
170-8022●
197-3864
197-3865
197-3866
197-3867
197-3868
197-3869
197-3870
197-3871
170-8023●
170-8024●
E5EN Series -
DIN & E5AN Series
1⁄4
Accessories
Output Unit - Pulse (NPN) 12V dc
Output Unit - Linear 4-20 mA
Output Unit - Linear 0-20 mA
Output Unit - Linear 0-5 V
Communication unit - RS232C
Communication unit - RS485C
E53-Q3
E53-C3N
E53-C3DN
E53-V35N
E53EN01
E53EN03
170-8063●
170-8064●
170-8066●
170-8068●
197-3846
197-3847
Zelio姞 Temperature Controllers
40
REG-24 1⁄32 DIN, REG-48 1⁄16 DIN and REG-96 1⁄8 DIN
170-8025●
170-8026●
170-8027●
170-8029●
170-8031●
170-8032●
170-8033●
170-8034●
170-8035●
170-8036●
170-8037●
170-8038●
Digital Temperature Controllers
1⁄8
170-8050●
170-8055●
197-3849
197-3852
197-3854
197-3855
170-8056●
170-8059●
197-3851
197-3853
DIN
E5AN-H
H = 96, W = 96, D = 78mm
REG-24
H= 24mm, W= 48mm,
D= 97mm
REG-48
H=48mm, W= 48mm,
D= 77.8mm
REG-96
H= 96mm, W=48mm,
D= 78mm
Ì High luminosity LED display providing excellent clarity in all lighting conditions
Ì Modbus communication for an increase in efficiency, consistency, and the ability to interface with PCs and other automation products
Ì Flash memory
Ì Compatible with a wide range of sensors: PT100 probe, thermocouple and current or
voltage sensors
Ì Advanced functions (standard): PID, fuzzy logic, auto-tuning, soft start
Ì IP66 resistance to dust
Ì Zelio control software used to configure the parameter settings
Operating temperature
Relative humidity
Vibration Resistance
Shock Resistance
Sampling time
-10°C to +50°C
90% without condensation
1 gn (10 to 70 Hz)
5 gn
REG-24 500ms
REG-48 and REG-96 200ms
Serial Port
1 x RS-485
Flow Rate
9600 and 19200 Kbits/s
Communication Protocol Modbus slave RTU, half duplex
Approvals
EMC EN 61326-1, LVD EN 61010-1, cURus (873), CSA C22.2 n2° 4-93, Gost
Supply
Output
No. Of Mftrs.
Voltage
Type
Outputs List No.
Process Control, Timers & Counters
Option Units
RS-232C Communications
E53-CN01N2
Heater Burnout/SSR Failure/Heater overcurrent/ E53-CNH01N2
RS-232C
Control voltage 2 (for driving SSR) and RS-232C E53-CNQ01N2
Communication
RS-485 Communication
E53-CN03N2
Heater burnout/SSR Failure/Heater overcurrent E53-CNH03N2
and RS-485 Communication
Heater burnout/SSR Failure/3-Phase Heater over- E53-CNHH03N2
current and RS-485 Communication
Control voltage 2 (for driving SSR)/RS-485 Com- E53-CNQ03N2
munication
Two event input
E53-CNBN2
Two event input - Heater burnout/SSR failure/ E53-CNHBN2
Heater overcurrent detection
Control voltage 2 (For driving SSR)
E53-CNQBN2
Two event input - Transfer output
E53-CNBFN2
Control voltage 2 (for driving SSR) and 3 phase E53-CNQHHN2
heater burnout/SSR failure/Heater overcurrent
Control voltage 2 (for driving SSR) and Heater E53-CNQHN2
burnout/SSR failure/Heater overcurrent
Control voltage 2 (for driving SSR) and Transfer E53-CNQFN2
output
100 to 240VAC None fitted, 2 slots
E5AN-HAA2HBM-500
100 to 240VAC
E5AN-HPRR2BM-500
100 to 240VAC Relay
E5AN-R3HMT-500N
100 to 240VAC Current
E5AN-Q3HMT-500N
100 to 240VAC Voltage (For driving SSR) E5AN-C3MT-500N
100 to 240VAC Voltage (For driving SSR) E5AN-C3ML-500N
24V ac/dc
None fitted, 2 slots
E5AN-HAA2HBMD-500
24V ac/dc
2 x SSR
E5AN-HSS2HHBFMD-500
24V ac/dc
Relay
E5AN-R3HMTD-500N
24V ac/dc
Current
E5AN-Q3HMTD-500N
Automation
Controllers
100 to 240VAC
Price Each
Order Code 1+
3+
5+
REG-24 1⁄32 DIN
E5EN-H
H = 48, W = 96, D = 78mm
Ì High Resolution display with 5 digits/0.01°C display
Ì High Accuracy - Thermocouple input: ±0.3% of PV, PT input: ±0.2% of PV, Analog input: ±0.2% FS
Ì High speed sampling cycle of 60 ms
Ì Universal inputs
Ì A PV/SV-status display function can be set to automatically alternate between displaying the status of the Temperature Controller (auto/manual, RUN/STOP, and alarms) and
the PV or SV.
Ì Preventive maintenance for relays in the Temperature Controller using a Control Output
ON/OFF Counter.
Ì Three-level display that simultaneously displays the PV, SV, and MV.
100 to 240V
100 to 240V
100 to 240V
100 to 240V
100 to 240V
24V
100 to 240V
24V
100 to 240V
24V
100 to 240V
24V
Solid State Relay Interface
Relay
Current
Current
Solid State Relay Interface
Solid State Relay Interface
Relay
Relay
Solid State Relay Interface
Solid State Relay Interface
Relay
Relay
1
1
1
1
1
1
1
1
1
1
1
1
REG24PTP1ALHU 197-3944●
REG24PTP1ARHU 197-3945●
REG24PTP1JHU 197-3946●
REG24PTP1JLU 197-3947●
REG24PTP1LHU 197-3948●
REG24PTP1LLU 197-3949●
REG24PTP1RHU 197-3950●
REG24PTP1RLU 197-3951●
REG24PUJ1LHU 197-3953●
REG24PUJ1LLU 197-3954●
REG24PUJ1RHU 197-3955●
REG24PUJ1RLU 197-3956●
2919
2920
farnell.com
Control Modes
Temperature/Process Controllers continued
Zelio姞 Temperature Controllers - continued
Output
No. Of Mftrs.
Voltage
Type
Outputs List No.
Automation
40
1
1
1
1
1
1
1
Price Each
Order Code 1+
REG48PUN1JHU
REG48PUN1JLU
REG48PUN1LHU
REG48PUN1LLU
REG48PUN1RHU
REG48PUN1RLU
REG48PUN2LJHU
3+
5+
197-3958●
197-3959●
197-3960●
197-3961●
197-3962●
197-3963●
Outputs
1
Relay
Logic
0-20 or 4-20mA
Logic
Logic
2
2
1
1
1
1
1
1
1
1
1
REG96PUN1JHU
REG96PUN1JLU
REG96PUN1LHU
REG96PUN1LLU
REG96PUN1RHU
REG96PUN1RLU
REG96PUN2LJHU
1
2
Relay
Relay
Relay
Relay
Relay
3
Relay
Relay
Fascia
Colour
Green
Green
Green
Green
Green
Input
Thermocouple
Type K
Type K
Type K
Type K
Type K
Setpoint
Limits
0 - 1000°C
0 - 1000°C
0 - 1000°C
0 - 1000°C
0 - 1000°C
Order Code
842-9782
842-9790
842-9804
842-9812
842-9847
381035
Mftrs. List No.
Order Code
3216/CC/VH/RR/XX/X/XXX/G/ENG/K/C5/H
3216/CC/VH/LR/XX/X/XXX/G/ENG/K/C5/H
3216/CC/VH/DR/XX/X/XXX/G/ENG/K/C5/H
3216/CC/VH/LR/XX/R/XXX/G/ENG/K/C5/H
3208/CC/VH/LRR/XX/X/XXX/G/ENG/K/C5/H
REG48PUN2LJLU
197-3966●
REG48PUN1RLU 197-3963●
REG48PUN2LRHU
197-3967●
REG48PUN2LRLU
197-3968●
REG48PUN2RHU 197-3969●
REG48PUN2RLU 197-3970●
REG48PUNL1LHU 197-3971●
REG48PUNL1RHU 197-3972●
1
1
Relay: 2A, 264V ac resistive
Logic: 40mA, 12V dc
(non-isolated from PV)
DC: 0-20mA into 500Ω max.
(non-isolated from PV)
IP66, NEMA4 plug-in from front
Price Each
197-3965●
1
Output Ratings
85-264V ac
Panel Sealing
-15 to 20%. 6 Watts max.
Operating Ambient 0-55°C, 5-85%RH
Current Transformer Input 50mA ac
Inputs
Refer to the order codes
REG-48 1⁄16 DIN
100 to 240V
Current
24V
Current
100 to 240V Solid State Relay Interface
24V
Solid State Relay Interface
100 to 240V
Relay
24V
Relay
100 to 240V Solid State Relay Interface
+ Current
24V
Solid State Relay Interface
+ Current
24V
Relay
100 to 240V Solid State Relay Interface
+ Relay
24V
Solid State Relay Interface
+ Relay
100 to 240V
Relay
24V
Relay
100 to 240V Solid State Relay Interface
100 to 240V
Relay
PID or ON/OFF
Supply Voltage
REG-24 1⁄32 DIN, REG-48 1⁄16 DIN and REG-96 1⁄8 DIN - continued
Supply
element14.com
1+
5+
10+
15+
842-9782
842-9790
842-9804
842-9812
842-9847
1/32 & 1/16 DIN PID Temperature Controllers
Models 2132 & 2116
REG-96 1⁄8 DIN
Process Control, Timers & Counters
100 to 240V
Current
24V
Current
100 to 240V Solid State Relay Interface
24V
Solid State Relay Interface
100 to 240V
Relay
24V
Relay
100 to 240V Solid State Relay Interface
+ Current
24V
Solid State Relay Interface
+ Current
100 to 240V Solid State Relay Interface
+ Relay
24V
Solid State Relay Interface
+ Relay
100 to 240V
Relay
24V
Relay
100 to 240V Solid State Relay Interface
100 to 240V
Relay
197-3974●
197-3975●
197-3977●
197-3978●
197-3979●
197-3980●
H=24, W=48, D=103
H=48, W=48, D=103
197-3981●
1
REG96PUN2LJLU
1
REG96PUN2LRHU
1
REG96PUN2LRLU
2
2
1
1
197-3984●
REG96PUN2RHU 197-3985●
REG96PUN2RLU 197-3986●
REG96PUNL1LHU 197-3987●
REG96PUNL1RHU 197-3989●
197-3982●
197-3983●
639537
Description
Pack
Mftrs.
Price Per Pack
Qty
List No.
Order Code
Accessories
Support for DIN rail
4
REG24PSOC
197-3943●
Terminal Block Cover
Terminal Block Cover
2
2
REG48PCOV
REG96PCOV
197-3957●
197-3973●
1+
Bright clear LED display gives excellent visibility in high and low ambient lighting
Operation is user friendly with tactile buttons
Three alarm setpoints are configurable for high, low and deviation alarms
Any combination of the alarms can be assigned to the relay output
Latching or non-latching operation can be selected
Calibration accuracy is preserved with a self correcting input circuit
User calibration facility allows offsets to be applied to compensate for sensor and other
system errors
Miniature PID temperature controller with heating, cooling and alarm outputs. Self-tuning is
included to optimise control performance without the need for specialist knowledge or
training. A universal input is configurable for nine thermocouple types, the PT100 resistance thermometer and linear 4-20mA. Two outputs are provided, a logic output to operate
a solid state relay and a relay output to operate contactors or solenoids. Either output can
be configured for heating, cooling or alarms. A timer function is provided which can start
or stop a process at the end of a set period.
Ì
Ì
Ì
Ì
Ì
Ì
Ì
5+
10+
Temperature Controllers
Control modes
No. of digits
Display
Display resolution
Supply
Power consumption
Input sampling rate
Display Units
Calibration accuracy
Input filtering
Alarm types
Operating ambient
Panel sealing
Relay rating
Logic rating
PID or ON/OFF control
Four with up to 2 dec. places
10mm high digits in green
Up to 2 decimal places
100 to 240Vac -15%, +10%
5 watts max
5Hz
°C or °F or Kelvin
The greater of ± 0.25% of reading, or ± 1c, or ± 1LSD
0-999,9 seconds
Low, high or deviation
0-55C
IP65, plug-in from front
2A, 240Vac resistive
9Vdc, 12mA
205772
Price Each
Mftrs. List No.
3216 Series - 48x48x90mm
3208 Series - 48x96x90mm
Available in two standard DIN sizes, the innovative 3200 controllers provide precise temperature control with a host of options. The front panel ’ammeter’ on the 1⁄8 DIN size displays the heater current or output power demand.
Ì In operation every parameter is accompanied by a scrolling text message describing its
function
Ì The current transformer input provides display of the heater current and a health check
on the load
Ì Partial load failure, heater open circuit and SSR (Solid state relay) short circuit are detected and displayed as scrolling alarm messages
Ì These instruments are suited to use in the plastics industry where input type J is the
standard
Ì The inputs on the 3200 can easily be configured from the supplied ’K’ to ’J’
Ì The internal timer is configurable as an interval timer, delay timer or to provide ’soft
start’ for hot runner control
Ì Input types are configurable, and can be changed through the front panel
2920
2132VH.
2116
Order Code
1+
5+
722-9902
722-9914
PID Control - ’2300 Series’
1/32 DIN
H=25, W=49, D=100, Panel Cut-out 45x22.5
Ì Compact but large four digit LED display controller
Ì Universal input selection T/Cs, RTD, mA/mV dc
Ì Two outputs as standard (1xrelay, 1xSSR) for control and alarm
functions
Ì Selectable ’EASYTUNE’ or manual PID adjust with pre-tune
Ì Sealed front fascia IP66
Ì CE approved and UL Recognised
10+
15+
farnell.com
Sensor Types
Linear Outputs
Accuracy
Outputs
Ambient Conditions
Thermocouples, Type J, L, T, K, B, N, R, S & RTD/PT100
0-20mA, 4-20mA, 0-50mV, 10-50mV
± 0.1% of input span (0.25% for J & T T/C) ± 1 LSD (T/C CJC better than 0.7°C)
Relay 2 A resistive @ 240V AC SSR 50mA @ 10V DC
0-55°C, 20-95% RH non condensing
204767
Price Each
Power Supply
90-264Vac
90-264Vac
Display Colour
Order Code
Red
Green
988-571
988-583
1+
5+
10+
25+
Simplified Temperature Controller
6500 Series - 1/16 DIN
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Thermocouple input
Easy Tune (PID) or On / Off
On control indicator
Foolproof operation
Set-point lock
Alarm lock
CE Approved and UL Recognised
Price Each
Mftrs. List No.
100-240VAC
N6500/Z2110-240VAC
Ì Universal temperature sensor and Analogue current
/ voltage input versions
Ì Screw-less clamp terminal contact blocks
Ì Auxiliary (relay) outputs that can be used to output
alarms or processing results.
Ì Additional terminal connections to achieve greater
I/O options
Ì High Control Output Current rating (2A)
O/A - H = 35, W = 48, D = 100mm Ì Wide input temperature range of -200 to 600°C
Ì Outstanding Indication accuracy (±0.2% FS)
Ì Fast 250ms sampling period
Ì Easy-to-read display features an 11-segment display and large indication characters
Ì Easily recognize status at a glance via a display that switches between 3 colors
Control Outputs
541793
Power Supply
E5GN Series - 48mm x 24mm (1/32 DIN)
Analogue Inputs
H=48, W=48, D=120, Panel cut-out 45 x 45mm
Order Code
Auxillary Output
Ambient
Temperature
Thermocouples - K, J, T, E, L, U, N, R, S, B, W or PLII
Platinum Resistance Thermometer - Pt100, JPt100
Infrared Temperature Sensor - 10 to 70°C, 60 to 120°C, 115 to 165°C or 140 to 260°C
Voltage Input - 0 to 50 mV
Current Input - 4 to 20 mA or 0 to 20 mA
Voltage Input - 1 to 5V, 0 to 5V or 0 to 10V
Relay - SPST-NO, 250V ac 2A
Voltage (SSR) - 12V dc ±15% (PNP), 21 mA Max.
Linear Current - 4 to 20 mA DC / 0 to 20 mA DC, load 500 Ω
SPST-NO, 250V ac, 2A (Resistave)
Operating: -10 to +55°C,
Storage: -25 to +65°C to 65°CC
601904
1+
Supply
988-595
Mftrs.
Order Code
Simplified Temperature Controller
E5GN-R1T-C AC100-240
179-4200●
6500 Series
24V ac/dc
E5GN-R1TD-C AC/DC24
179-4201●
1/16 DIN controller with large 3 digit LED display
Input selection T/C & RTD
Two outputs - Relay and Alarm Relay
EASYTUNE (PID) optimises control without operator
intervention
Setpoint lock
Alarm lock
Sealed front fascia IP66
CE Approved and UL Recognised
Supply
Voltage
100 to 240VAC
Voltage Output (SSR) + 1 Auxiliary Output
100 to 240VAC
24V ac/dc
Temperature
Temperature
E5GN-Q1T-C AC100-240
E5GN-Q1TD-C AC/DC24
179-4202●
179-4203●
Linear Current Output + 1 Auxiliary Output
100 to 240VAC
Temperature
E5GN-C1T-C AC100-240
24V ac/dc
Temperature
E5GN-C1TD-C AC/DC24
24V ac/dc
Analogue
E5GN-C1LD-C AC/DC24
179-4204●
179-4205●
179-4208●
Outputs
Mftrs.
1
2
List No.
Relay Control Relay Alarm N6500/Z2110
Order
Code
988-595
E5CSV Series
Ì
Ì
Ì
Ì
Ì
Ì
Ì
204766
Price Each
Power Supply
Order Code
100-240VAC
988-595
40
1+
5+
10+
25+
Easy setting using DIP and rotary switches
1 alarm output
Multi input support for both thermocouple or PT100
Clearly visible digital display
Character height of 13.5mm
Available for 100-240Vac or 24V dc supply
Available with relay or voltage output
General Purpose Process Controller - ‘6100 Series’
1/16 DIN - On/Off or PID
Supply voltage
Sensor Types
94-256 Vac or 20-50 Vac/22-65 Vdc
Thermocouples, Type J, L, T, K, N, B, R, S & RTD/
PT100
Linear Inputs
0-20mA, 4-20mA, 0-5mV, 1.5mV, 0-10V, 2-10V
Accuracy
±0.25% of span, ±1 LSD
Outputs
Relay 2A resistive @ 240Vac, SSR 4.2V 1k Ω min
DC 0-20mA, 4-20mA, 0-10V, 2-10V
Ambient Condi- 0-55°C, 20-95% RH non condensing
tions
H=48, W=48, D=100,
Panel cut-out 45x45
Output Range
0 - 10V dc
0 - 20mA dc
0 - 5V dc
4 - 20mA dc
Link Jumper Fitted
LJ8
LJ9
LJ8
LJ9
Ì Multi-functioned programmable PID
controller
Ì Universal input for t/c, 3-wire RTD,
mA, mV and V
Ì Broken sensor detection and loopfailure alarm
Ì Select Relay or DC (4-20mA,0-10V)
for control output 1
Ì Optional output 2 - Relay or DC for heat/cool
control or alarm
Ì Optional output 3 - alarm or recorder output
Ì Optional RS485 serial communications
Ì Optional digital input for remote selection of
dual setpoint
Ì IP66/NEMA 4 plus full CE approved and UL
recognised
Supply Voltage
Inputs
Control Output
Alarm Output
Ambient Temperature
H = 48, W = 48, D = 78mm
100 - 240VAC or 24V dc
K, J, L, T, U, N, R,
Pt100, JPt100,
Relay (SPST-NO, 250V ac 3A) or Voltage (12V dc 21mA)
SPST-NO, 250V ac, 1A
Operating: -10 to 55°C Storage: -25 to 65°CC
460606
Price Each
Voltage
Output
Mftrs. List No.
Order Code
100 to 240VAC
100 to 240VAC
24 to 24VDC
24 to 24VDC
Relay
Voltage
Relay
Voltage
E5CSVR1T500AC100240V
E5CSVQ1T500AC100240V
E5CSVR1TD500ACDC24V
E5CSVQ1TD500ACDC24V
133-7266●
133-7267●
133-7268●
133-7271●
Output 1 Type
Order Code
Relay
308-0080
Optional Modules
Single C/O Relay (S1)
SSR Driver Output (S1)
Linear mA/V DC Output (S1)
Single C/O Relay (S2/3)
Linear mA/V DC Output (S2/3)
RS485 Serial (SA)
Remote Setpoint Input (SA)
979-5243
979-5251
979-5260
979-5278
979-5294
979-5316
979-5332
1+
5+
10+
25+
10+
11 segment clearly readable LCD display
3 colour change display, green, red and orange
3 phase heat monitor
The fast input sampling is 100ms for analogue and 250ms
for temperature inputs
Ì Loop break alarm and sensor break alarm
Ì Simple 2 step programmer
Ì IP 66 rated front panel
Ì
Ì
Ì
Ì
204765
90-264 Vac
5+
E5CN Series Temperature Controller
Price Each
Power Supply
1+
Process Control, Timers & Counters
Thermocouple
Temperature
1+
Temperature Controllers
H=48, W=48, D=100, Panel cut-out 45 x 45mm
Input
Input
Automation
List No.
Ì
Ì
Ì
Ì
Voltage
Price Each
Relay Output + 1 Auxiliary Output
100 to 240VAC
Temperature
Ì
Ì
Ì
Ì
2921
Temperature Controllers - Basic
Temperature
Inputs
The 6500 features a simplified operator interface and an automatic self-tune process at
start-up. Clear Go / No-go "on control" indicator and a large high visibliity 3 digit display.
element14.com
Mftrs.
Output Alarm
Voltage
List No.
Temperature Input Models (Thermocouple, PT100 and mV)
TC/Pt/mV Relay 2
100 to 240VAC or 24VDC/VAC
E5CN-R2MT 500 100/240AC
Input
Order Code
860-5548
382675
Price Each
Mftrs. List No.
Temperature Input Models
E5CN-R2MT 500 100/240AC
Order Code
1+
5+
10+
860-5548
2921
2922
farnell.com
Touch Panel Screen
element14.com
di08 / di32 Digital Indicators
Ì Configurable inputs and outputs
Ì Structured operating and programming layout
Ì Customized linearization adjustment
Ì Min/max/hold function via external contact
Ì Easy-to-read display thanks to large LED
(20 or 10mm)
Ì IP66 enclosure protection
Ì Levels can be inhibited to prevent unintentional alterations
Ì Configurable relay switch-on delay
Ì Two relay outputs and logic output 0/5V
5.7 Inch Colour Touch Panel Screen
Ease of use and single configuration software
Push-button style mounting system
Embedded Ethernet
Multi-protocol RS232 / 485 RJ45 ports
Optimum visibility
Certifications: C-Tick, CULus and UL class 1 Div2 T4A
ou T5
Ì Standards: EN 61131-2, FCC Class A, IEC 61000-6-2,
UL 1604 and UL 508
Ì
Ì
Ì
Ì
Ì
Ì
H= 129.15mm, W= 163mm,
D= 56.5mm
Operating temperature
Voltage rating
Power
IP degree protection
0°C to +50°C
24 VDC
6.8 W
IP20 (rear panel) conforming to IEC 60529
IP65 (front panel) conforming to IEC 60529
NEMA 4X front panel (indoor use)
QVGA TFT colour touchscreen
65536 colours
320 x 240 pixels
Analogue
50000 hours
16 levels
ASCII, Chinese (simplified Chinese), Japanese (ANK, Kanji), Korean
and Taiwanese (traditional Chinese)
333 MHz
Application memory - 16 MB, Back up of data - 64 kB
NEMA degree of protection
Display type
Display colour
Pixel resolution
Touch panel
Backlight lifespan
Brightness
Character font
Processor frequency
Memory
Technical Data:
Supply Voltage 110...240V AC, 48...63Hz
Inputs
di 08
Bezel Size
Display:
Outputs
Resistance Thermometers
Pt100, Pt1000, KTY11-6
Thermocouples
Typ L, J, U, T, K, N, S, R, B, D, C
Current
0...20mA, 4...20mA
di 32
Bezel Size
Display:
Display
Voltage
0...10V, 2...10V
48 x 96mm
4-digit LED, red, 20mm high
2 Relays (SPST-NO)
1 binary output 5V/20mA
24 x 48mm
4-digit LED, red, 10mm high
1 Relay (SPST-NO)
1 Binary Output 5V / 20mA
Binary Input
Floating Contact
333863
Price Each
639644
Mftrs.
Automation
40
Type
Price Each
List No.
Order Code
HMISTU855
197-3991●
1+
3+
Process Control, Timers & Counters
Ì Multi-range DC voltage/current input
Ì Front-panel key operation for easy setting
Ì Average processing function suppresses flicker
Ì Scaling, front-panel forced-zero, zerolimit functions
Ì Easy confirmation of max/min display
Ì Short 80-mm depth (measured from
edge of face plate)
Ì Finger protective cover (standard equipment) guards against electric shock
Ì Water- and dust-proof NEMA4X (IP66 equivalent) front panel
Ì Recognized to U.S. and Canadian requirements under the Component Recognition Program of UL with CE marking
Supply
Voltage
100 to 240VAC
Mftrs.
List No.
K3MAJA2100240VAC
Output
2 Relay Contact Outputs (SPST - NO)
473371
Mftrs.
Price Each
List No.
Order Code
K3MAJA2100240VAC
135-0605●
1+
5+
10+
Ì Wide input range - select from two
types of platinum-resistance thermometers and ten types of thermocouples
Ì Front-panel key operation for easy setting
Ì Average processing function suppresses flicker
Ì Temperature input shift and temperature
unit selection functions
Ì Easy confirmation of max/min display
Ì Short 80-mm depth (measured from
Supply
Voltage
100 to 240VAC
Output
1 Relay Contact Output (SPDT)
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Limit monitoring with 10A changeover (SPDT) relay
Adjustable switching differential
Configurable alarm suppression
Symbols in display for temperature unit, minutes, seconds
Parameter level protected by code
Each parameter can be individually enabled for operation
Easy mounting
Panel mounting
Electrical connection via screw terminals, 2.5mm² stranded wire or 4mm² solid wire
UL and CUL approval applied for
Programmable switch-on delay after power-on
Technical Data:
Supply Voltage
Input
Ouput
Accuracy
Bezel Size
IP Rating
Operating Temperature
Price Each
Order Code
K3MALC100240VAC
135-0607●
DC 24V
Pt100 / Pt1000 / KTY 2X6, freely adjustable
Floating changeover contact (SPDT) 10A / 250V
0,1%
76 x 36 mm
IP65 at front
0...55°C
333864
Type
Mftrs. List No. Order Code
951540/888-18 24VDC
95/00413077
1+
5+
10+
1+
5+
10+
472-4628
eTRON T
Digital thermostat with LCD display for DIN rail mounting
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Configurable heating or cooling operation
Adjustable switching differential
Simple operation from 3 keys
Mounting on DIN rail
Dimensions: 90 x 22.5 x 60 mm
Electrical connection by screw terminals
Enclosure protection: IP20
Technical Data:
Supply Voltage
Input
Output
Accuracy
Mounting
Operating Temperature
Mftrs.
List No.
K3MALC100240VAC
473376
Mftrs.
List No.
10+
Price Each
Temperature Meter
Input
Type
Platinum-resistance Thermometer or Thermocouple
5+
Digital temperature indicator, microprocessor-controlled, with 10A changeover (SPDT) relay, in 76mm x
36mm format
Process Meter
Input
Type
DC Voltage/Current
1+
472-4598
472-4604
Di Eco Indicator
LED Process Indicators
edge of face plate)
Ì Finger protective cover (standard equipment) protects against electric shock
Ì Water- and dust-proof NEMA4X (IP66 equivalent) front panel
Ì Recognized to U.S. and Canadian requirements under the Component Recognition Program of UL with CE marking
2922
Mftrs. List No. Order Code
di32 24 x 48 mm 95/00387989
di08 48 x 96 mm 95/00387993
5+
Ì UL and CUL approval
Ì 3-digit LC display with special symbols °C, °F
Ì Parameter level protected by
code
Ì 10 A load relay
Ì Limit monitoring
230VAC / 115VAC / 24VDC / 12VDC
Pt100 / Pt1000 / KTY 2X6, free adjustable
Floating changeover contact 10A / 250V
0,1%
35 x 7.5mm DIN rail to EN 50 022
0 to 55°C
333869
Price Each
Type
Mftrs. List No.
ecoTRON T 24V DC
ecoTRON T 230V AC
701050/811-31/061
701050/811-02/061
Order Code
472-4197
472-4239
1+
5+
10+
farnell.com
A panel meter that combines simplicity with versatility,
the easy to use menu structure makes this controller
suitable for simple applications while the advanced
functions make it suitable for more complicated ones.
Using the same display that was first developed for the
E5N temperature controller. the K3GN offers a high visibility reverse lit LCD display that can be configured to
change colour when the outputs are either activated or
de-activated.
Ì Configurable analogue inputs: 4-20mA, 0-20mA, 1-5VDC, 0-5VDC,-5 to +5VDC, and
-10 to +10VDC. These are fully scaleable so can be configured to represent a wide
range of engineering inputs.
Ì Non voltage and open collector inputs suitable for sensors, encoders and pulse inputs
from 0.05 to 30.00 Hz and 0.1 to 5000.0 Hz
Ì All of the inputs are simple to scale by setting the lower and upper limits and what
these are to represent the K3GN will automatically linearise these to the scale required
Ì 24x48mm DIN1/32 and panel depth of 80mm
Ì 24VDC input voltage -15%to +10%
Ì Choice of either 2 relay (3A @250VAC or 30VDC) or 3 transistor outputs (choice of
NPN or PNP), that can be configured to give a wide selection of levels including HH, H,
LL, L or band (on each output). When using transistor outputs the 3rd output is for a
pass output.
Ì Programmable display to change colour when activation or de-activation of outputs.
Ì Meets all current European noise and emissions regulations and the unit is CE marked
Ì Other standards approvals include VDE, and CSA UL recognised
Ì Front Fascia protected to NEMA4X (indoor) IP66.
Universal Intelligent Panel Meter
Transfer Function Module Library
H = 48, W = 96, D = 140mm
D (Behind panel) = 131,
Cutout = 45 X 92mm
535022
Supply
Mftrs.
Voltage
90 - 264V ac
20 - 35V dc
1+
5+
424-5167
Connector types Screw terminals (supply - 2 way,
input -4 way)
Measuring rate/in- 3 per sec/80ms
Wire size
4mm2 single core, 2.5mm2 standard wire
tegration
Measuring ranges 0.2 ... 300Vdc/10 ranges
Safety
IEC 1010, class 1, over voltage
category II 264V
1.0 ... 300mAdc/8 ranges
Degree of polution 2
Zero correction/ Automatic/up to +25% or range EMC
IEC 801, VDE 871, Class B
offset
(for 4-20mA, etc.)
Operating temper- 0 to 50°C
ature
228882
Price Each
1+
5+
10+
25+
766-800
Temperature Indicators
Thermocouple and Platinum Resistance
Large 11.2mm 31⁄2 digit LED display
Standard 96x48mm DIN case
Slimline design, depth behind panel only 63mm
Quick-release plug-in rear terminals for supply and
sensor
Ì Thermocouple instruments have automatic cold
junction compensation
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Desption
Price Each
List No. Order Code
107-437
530-037
1+
5+
List No.
230 - 240VAC
24VDC
Price Each
Order Code
1+
5+
10+
72.01.8.240.0000 134-4231●
72.01.9.024.0000 134-4232●
Accessories
Stainless Steel Electrode
Electrode Connector
Suspended Electrode, 6m
Suspended Electrode, 15m
3-Way Electrode Holder
072.500
072.501
072.01.06
072.01.15
072.53
134-4193●
134-4194●
134-4196●
134-4197●
134-4198●
Zelio - Liquid Level control Relay
RM35L Series
Ì Control by resistive level probe
Ì Monitors the levels of conductive liquid or
non-conductive material
Ì Control the actuation of pumps or valves
to regulate levels
Ì Suitable for protecting submersible pumps against dry running
or protecting tanks from overflow
Ì Used to control dosing of liquids in mixing processes and to
protect heating elements in the event of non immersion
Ì Have a transparent, hinged cover on their front panel to avoid
any accidental alteration of the settings
H = 90mm, W = 35mm
and D = 72mm
228883
Type K thermocouple
4501
PT100 platinum resistance 4504A
Mftrs.
Voltage
Measuring range
Mftrs.
Low voltage on probes
LED status indication
Compact size, 35mm width
35mm rail mount
cULus approval
473033
Input
Overall dims: H=48, W=96, D=68.1
Panel cut-out=92x45
K: -50°C to +700°C (-60°F to 1300°F)
J: -50°C to +625°C (-60°F to 1160°F)
T: -50°C to +350°C (-60°F to 660°F)
PT100: -99.9°C to +199.9°C
Resolution
K, J, T: 1°, PT100: 0.1°
Accuracy
K, J, T: ±0.5% of reading ±1 digit
PT100: ±0.2% of reading ±0.2°C/0.5°F
Power supply
/ ac ± 15% 50/60Hz
Note: PT00 instrument is suitable for installation with 2 or 4 wire sensor only.
Ì
Ì
Ì
Ì
Ì
Fail to safe emptying or filling functions
Single or two point control
Adjustable sensitivity
Switch selectable time delay
Reinforced insulation
40
Process Control, Timers & Counters
Resolution/display±1999 digit/7 segment red LED
230 - 240VAC, 50/60Hz
24VDC
Output
Rated Current/Max Peak Current
16/30A
Rated Voltage/Max Switching Voltage
250/400V ac
Rated Load AC1
4000VA
Rated Load AC15 (230V ac)
750VA
Single phase motor rating (230 V ac)
0.55kW
Breaking capacity DC1: 30/110/220V
16/0.3/0.12A
Electrical life at rated load AC1
100,000 cycles
Electrode Voltage
4V ac
Electrode Current
0.2mA
Delay Time
0.5 or 7 sec (Selectable)
Sensitivity Range
5 to kΩ (adjustable)
Insulation between supply/contacts/electrodes 6kV (1.2/50ms)
Ambient Temperature
-20 to 60°C
Protection Category
IP20
Ì Configured by rear pluggable links and presets
Ì Adjustable zero offset (eg 4-20mA=0-1500 display)
Ì 230V ac supply
Ì IP65 sealed front fascia
Ì 13 or 20mm character sizes
Ì 2000 count display range
Ì 10 volt ranges and 8 current ranges (dc)
Order Code
1+
10+
31⁄2 Digit, Voltage and Current Indicator
DPM48/2000SNT20(230VAC)
Order Code
170-6804●
170-6805●
Fluid Level Controls
S Range
Mftrs. List No.
List No.
DM3600U/S1
DM3600U/S2
Nominal Supply Voltage
Input DC Voltage / Current, NPN
2 Relay, SPDT
K3GN-1001A
H = 48, W = 96, D = 151mm
Panel Cut-Out - 92.8 x 46.1mm
Price Each
Level Control Relay
Price Each
Order Code
WARRANTY
YEARS
Automation
Mftrs
5
Ì Internal Power Supply for Loop Exitation
Ì Universal Input
Ì Custom Software For Your Application Option (TFML)
Ì 6 Digit Display
Ì IP65 Sealed Front Ì Programmable Via The Front Panel Or Remote PC
Ì User Non Linear Function For Tank Level Applications
24VDC
List No
The DM3600 is an intelligent digital
panel meter that can accept inputs
from a wide variety of sensors and
display the signal digitally.
The DM3600 is available in two versions, AC supply or DC supply. All
functions are programmable via the integral front panel keys.
The DM3600 supports TFML (Transfer
Function Module Library) i.e. the ability to download custom functionality by means of standard modules available from the manufacturers web
site. This allows pre-written or custom control functions to be quickly and easily incorporated.
248524
Output
2923
Universal/SMART Indicator
Smart Panel Meter - K3GN
Supply voltage
element14.com
10+
25+
Applications:
Ì Spring, town, industrial and sea water Ì Non concentrated alcohol (< 40 %)
Ì Metallic salt, acid or base solutions
Ì Liquids in the food processing industry:
Ì Liquid fertilizers
milk, beer, coffee, etc.
Output contacts
Nominal output current
2 C/O Operating temperature
5A
Switching capacity
-20°C to +50°C
1250 VA
2923
2924
farnell.com
Fluid Level Controls - continued
Valve Control Module
Zelio - Liquid Level control Relay - continued
Weidmuller - Valve Control Modules
RM35L Series - continued
ACT20X
640473
Delay time
Range
Mftrs.
Price Each
List No.
Order Code
1+
5+
10+
25+
50+
24V - 240V AC, 50-60Hz Supply voltage
0.1s to 5s RM35LM33MW 205-6348●
Liquid Level Control
Type P48LCR
Ì PUMP UP or PUMP DOWN mode switch - Selectable
Ì 1 or 2 Probe operation
Ì Uses low voltage AC current across probes prevents
electrolysis phenomenon
Ì Adjustable sensitivity
Ì Dual voltage
Ì Output relay - SPCO 8A contact
Ì 11-Pin Plug-in
Ì Conforms to CE
H = 48, W = 48, D = 75mm
618348
Price Each
Mftrs. List No.
Order Code
1+
5+
Ì The ACT20X-SDI-HDO/2SDI-2HDO valve control
modules are controlled from the safe zone on the
input side by the switching signals (NPN, PNP) and provide digital outputs to switch actuators (solenoids, alarms) in Ex Zone 0
Ì Depending on the module, the output current is limited for the ignition protection groups IIC/IIB to 35 mA or 60 mA (only one
channel).
Ì Integrated alarm contacts issue an alert in the event of a malfunction which makes troubleshooting easier and increases the system availability
Ì The rail mounted disconnect-switch amplifiers are optionally
available in one- or two-channel versions
H = 113.6 W = 22.5, Ì With 11 mm width per channel, the devices need little space in
D = 119.2mm
the electrical cabinet
660189
Price Each
Ignition Protection Group
Mftrs. List No.
Order Code
1 Channel
IIC 35mA
8965400000
207-0755●
IIB <60mA
8965410000
207-0756●
8965420000
207-0757●
8978580000
207-0761●
5+
10+
Accessories
USB Interface
Automation
Tachometer Relays
Floatless Liquid Level Control
High Precision Tachometer Relay
Type E-FLC3
50 to 1,000 RPM
Process Control, Timers & Counters
Ì Designed to monitor the level of a liquid within a tank or
container
Ì 3 levels of monitoring - Low, High and Alarm levels
Ì Fixed Operate and Release Resistance
Ì Up to 1km distance between controller and probes
Ì Built in Surge Arrestors protect each probe input against
lightning strikes
Ì Unique LED indication of probe/tank level status
Ì Additional LED indication for supply and relay output
status
H = 85, W = 70, D = 63.5mm Ì 1 x SPDT relay output (Output 1) and 1 x SPNO relay
output (Output 2 - Alarm)
Ì DIN Rail mount
Ì Conforms to IEC and CE
618349
Price Each
Mftrs. List No.
Order Code
230V ac Supply voltage
EFLC3 240VAC 50/60HZ
185-3781●
1+
5+
10+
Contact arrangement
Contact rating
Supply voltage
Power consumption
Metering output
Sensor supply
Sensor input
Weight
SPCO
5A @ 240V ac resistive
110V ac or 240V ac, 50Hz (-15, +10%)
<3VA
1mA fsd into 75Ω
25mA/ 15Vdc 3 wire or 5mA/ 8V dc 2 wire
NPN Transistor NO, or NO contacts
200g
H=48, W=48, D=87 (behind panel) Panel cut-out = 45x45
An electronic relay for sensing pulse produced by rotating machines or other pulse counting applications. The input pulses can be from a volt-free contact, 2 or 3 wire proximity
sensor, or an NPN open collector transistor. The relay has a 15V dc supply terminal to
power solid state sensors.
Housed in a grey fire retardant ABS 48mm DIN case, the units can be panel or chassis/DIN
rail mounted using a suitable socket.
Three sensing ranges are available from 50 to 1,000 RPM with adjustment through a lockable potentiometer (Allen key supplied) over a 20:1 range. When the set speed is reached,
the output contacts change over and the green panel front LED illuminates. A 1mA fsd metering output enables continuous monitoring of the input. A further red LED indicates the
presence of mains supply. Front panel or chassis mounting via 11 pin relay base.
231485
Miniature Controller - 61FGPN
Price Each
Ì Space saving, conductive level controller
Ì Intended for single or two point level control of
conductive materials (liquid or solid)
Ì Electrical connections are via a plug-in octal base
Operating voltage
Electrode voltage
Output
Dielectric strength
Power consumption
Temperature range
110VAC or 240VAC (-15%, +10%)
8V ac
Changeover relay 5A @ 240V ac/24V dc
1500V ac 50/60Hz
3.2VA max.
-10°C to +55°C
Sensing Range
Mftrs. List No. Order Code
50 to 1000 RPM
TR480102
5+
10+
25+
Zelio - Speed control Relay
Ì Operates with either N/O or N/C sensors
Ì The power on inhibition time is adjustable from 0.6 to 60 seconds
Ì Settings are protected by a sealable cover
Applications:
Ì Monitors speed or rate of rotary or linear movements in conveyor
belts, packaging and mechanical handling
H=50, W=38, D=70
204706
Operating
1+
275-220
Speed Controller
Mftrs. List No. 61FGPN2 110Vac=177-887, 61FGPN2
240Vac=177-888, PF083AE=1340949
Price Each
Voltage
Order Code
110VAC
240Vac
Surface/DIN
177-887
177-888
rail socket
134-0949●
1+
1+
5+
25+
10+
25+
H = 90mm, W = 35mm and D = 72mm
Output contacts
1 C/O
Nominal output current
5A
Operating temperature
Switching capacity
-20°C to +50°C
1250 VA
640474
100+
Delay time
Mftrs.
Range
List No.
Price Each
Order Code
24V - 240V AC/DC, 50-60Hz Supply voltage
0.05s to 10min RM35S0MW 205-6349●
The first online technical portal for design engineers
Log on, research, refine and design
2924
1+
2 Channel
IIC 35mA
+
115 or 230V ac, 48 - 63Hz Supply voltage
P48LCR 115/230VAC
185-3768●
40
element14.com
1+
5+
10+
25+
+
farnell.com
Shaft Rotation Sensing Relay
ILPH Range
11 Pin Relay Base
An electronic relay that gives an output when the rotation of
a machine shaft ceases. Inputs from a 3-wire inductive
proximity sensor, determined by the speed of shaft rotation,
resets a timer within the sensor and prevents the output
contacts from energising.
Potentiometer control for time delay 1 to 30 secs. If a pulse
is not received within the set period the sensor energises
and an LED indicates the shaft has stopped.
The relay can be front panel or chassis mounted via an 11
pin relay base.
SPCO
Scale Range
1 to 30s
5 A @ 240V ac resistive Sense time for detection 3ms min
240VAC or 110VAC 50Hz Shaft rotation speed
10000 rpm max.
+10%/-15%
<4VA
Power Consumption
204802
Price Each
Type
Mftrs. List No.
Relay
FSRST 30SLP 110/240VAC 170-961
Order Code
1+
5+
10+
25+
Frequency Converter
In the field of industrial data transmission, various processes of data transmission and interfaces are used today. Already existing systems need to
be updated or connected to new devices for continuity of
process. When new communication functions are not
build-in, ABB propose a range of converters to be able to
use from the standard RS232 or RS485, to the Ethernet open products or the Optical Fiber.
636883
Mftrs.
Description
Voltage
List No.
Order Code
IFMA0035
IFMA0065
125-3405●
125-3406●
9 - 32VDC
85 - 250VAC
Price Each
1+
5+
Ì
Ì
Ì
Ì
Ì
Ì
Single Output
Miniature
H = 81, W = 37,
D = 36.8mm
Single Output
Leaded
Head - H = 48.1,
Dia. = 80.5mm
Sensitivity adjustment from 1 to 80 lux
Electronic circuit - transformer isolated
Light feedback compensation innovative principle
230V ac supply
Compatible with slow starting gas discharge lamps (up to 10 minutes)
For the first 3 working cycles the delay time is reduced to zero to aid installation
Type
Mftrs.
List No.
Price Each
Order Code
1+
25+
100+
Single output for live switching
1NO - 16A @ 230V ac 10.41.8.230.0000 188-9066●
RS232
RXD: max. ±30V dc, mark condition: <0.8V dc, space condition: >2.4V dc
TXD: mark condition -8V dc Typ., space condition +8V dc Typ.
RS485
Differential output voltage: ±5V dc max. ohne last;
Differential input voltage ±5V dc mac., mark condition <0.2V dc, Space condition:
>0.2V dc
RS485 Drive CapatibilityUp to 32 RS485 receivers connected in parallel
Baud Rate
9600 min, 19200 max.
Operating Temperature 0 - 50°C
Power supply
9 to 32V dc @ 75mA Max.
Dimensions (WxHxD) 25x79x90.5mm
443141
Mftrs.
Price Each
Order Code
10 Series
Double Output for live and neutral switching
2NO - 16A @ 230V ac 10.32.8.230.0000 188-9065●
Ì Converter between RS232 control equipment
and products with RS485
Ì Wide DC input power range (+9 - +32V dc)
Ì Half duplex (RS485) and full duplex (RS422)
Ì LED indication for RXD, TX and power
Ì Universal mounting foot for Din Rail installation
125-3394●
Light Dependent Relays
Output
Serial Converter Module
List No.
189-5960●
627493
10+
Serial Converter
ICM40030
5+
1+
5+
10+
Two independent outputs
2NO - 16A @ 230V ac 10.42.8.230.0000 188-9067●
Single output - Miniature
1NO - 12A @ 230V ac 10.51.8.230.0000 188-9068●
Single output - Circular with lead wires
1NO - 16A @ 230V ac 10.61.8.230.0000 188-9069●
Light Dependent Relays
40
Process Control, Timers & Counters
Mftrs.
1+
Integral light sensor with relays for automatic control of lighting according to ambient light
level. For pole or wall mounting.
443159
Supply
Order Code
189-5950●
189-5951●
189-5952●
189-5954●
189-5955●
189-5956●
189-5957●
189-5958●
189-5959●
Lighting Controller
Double Output
H = 110.6,
W = 58.6,
D = 40mm
DIP-switch selectable for switch contacts,
CMOS, TTL circuits, magnetic pickups, NPN, PNP
±90V dc, 2.75mA Max.
From 0Hz - 25kHz; User selectable
0 - 5V dc, 0 - 10V dc, 0 - 20mA, 4 - 20mA
±0.1% of full scale range (±0.2% for 0 - 5V dc range)
Voltage: 3.5mV min, Current; 5μA min.
5ms. +1 period to 10 sec. + 1 period; user selectable
0 - 50°C
(AC Version Only) +12V dc ±25% @ 60mA Max.
9 - 32VDC, 2.5W Max. or - , - , 6.5VA
27.5x79.2x106.7mm
Max. Input Signal
Input Frequency Range
Signal Output
Accuracy
Resolution
Response Time
Operating Temperature
Sensor Supply
Power Supply
Dimensions (WxHxD)
List No.
Automation
Simple on-line range setting
User settable full scale frequency from 1 Hz to 25 kHz
Four output operating ranges
Programmable input circuit accepts outputs from a variety of
sensors
Ì Low frequency cut-out and overrange indication
Ì 3-way electrical isolation
Ì Universal mounting foot for Din Rail installation
Ì
Ì
Ì
Ì
Price Each
RS422 to RS485 (Isolated)
1SNA684212R2200
RS232 to RS422-485 (Non-isolated)
1SNA684231R2500
RS232 to RS422-485 (Isolated)
1SNA684233R2700
RS232 to RS232 (3 Way Isolated)
1SNA684234R2000
RS232 to FO-S (3 Way Isolated)
1SNA684236R2200
RS232 to FO-P (3 Way Isolated)
1SNA684238R0400
RS485 to FO-S (3 Way Isolated)
1SNA684246R0400
RS485 to FO-P (3 Way Isolated)
1SNA684248R1600
RS232 to RS485/Ethernet (3 Way Isolated) 1SNA684252R0200
RS232 to RS422-485/Ethernet (3 Way Iso- 1SNA684333R2300
lated)
Frequency to Analogue Converter
Signal Input
2925
Serial Data Converters
Rotation Sensing Relay
Contact arrangement
Contact Rating
Supply Voltage
element14.com
11 Series
Relays for automatic control of
lighting according to ambient light
level, supplied with seperate light
sensor. For DIN Rail mounting.
Ì LED Status indication
Ì SELV separation between contact and supply circuit
Ì Double insulation between supply and light sensor
Ì 230V ac supply. 24V ac/dc model available
Ì For the first 3 working cycles the delay time is reduced to zero to aid installation
IMPROVED BACK ORDER DELIVERY
Receive email updates with the exact status, due
date and despatch information of all your back
order items farnell.com
2925
2926
farnell.com
Lighting Controller - continued
element14.com
Zelio Control - Voltage Control Relays
Light Dependent Relays - continued
11 Series - continued
Supply frequency
Output Current
Operating temperature
Relative humidity
IP degree of protection
627497
Output
Mftrs.
Type
List No.
Price Each
Order Code
1+
25+
100+
Single Output - 24V ac/dc Supply
1NO - 16A @ 250V ac
11.31.0.024.0000 188-9070●
Approvals
Electrical durability
Power consumption
Single Output
1NO - 16A @ 250V ac
50/60 Hz @ ±10%
5A
-20°C to +50°C
95% at 55°C conforming to IEC 60068-2-30
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
CSA, C-Tick, GL, GOST and UL
100000 cycles
RM17 U: ≤ 1W
RM35 U: ≤ 0.6W
11.31.8.230.0000 188-9071●
Single Output - Zero Hysteresis with 4 Position selector
1CO - 16A @ 250V ac
11.41.8.230.0000 188-9073●
Ì Monitors both a.c. and d.c. voltages
Ì Monitors their own supply voltage, measured as true rms value
Ì Protection of electronic or electromechanical devices against overvoltage and undervoltage
Ì Adjustable time delay prevents spurious triggering of the output relay
Ì Selection between overvoltage and undervoltage
Ì Fault signalling is by LED
Two independent Outputs. Two Individual Lux settings. 4 Position selector
1NO / 1CO - 12A @ 250V ac
11.42.8.230.0000 188-9074●
Light Dependent Relay + Time Switch - 1 Output + 1 Auxillary Output
1CO - 16A @ 250V ac
11.91.8.230.0000 188-9075●
Accessories
Connecting Link for 11.91
011.19
640461
Supply
Measurement
Output Mftrs.
Power Relay Module
Voltage
Range
Contacts List No.
19 Series
110 to 240 V AC/DC 65 to 260 V
110 to 240 V AC/DC 65 to 260 V
24 to 240 V AC/DC 15 to 600 V
Automation
Ì
Ì
Ì
Ì
Ì
Ì
Suitable for lamp loads
Heavy duty, high inrush current loads
12V dc supply
LED Indicator
Reinforced insulation between supply and contacts
35mm DIN Rail mounting
Mftrs.
List No.
Price Each
Order Code
1+
10+
50+
Single Output - 24V dc Supply
1CO - 16A @ 250V ac
19.91.9.012.4000 188-9076●
Process Control, Timers & Counters
Accessories
Connecting Link for 19.91
011.19
Supply frequency
Output Current
Operating temperature
Relative humidity
IP degree of protection
188-9077●
Current and Voltage Controls
Approvals
Electrical durability
Hysteresis
Power consumption
Ì
Ì
Ì
Ì
24 to 240 V AC/DC
50/60 Hz @ ±10%
5A
-20°C to +50°C
95% at 55°C conforming to IEC 60068-2-30
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
CSA, C-Tick, GL, GOST and UL
100000 cycles
RM17 JC: 15% fixed of threshold setting
RM35 JA: 5 to 50% of threshold setting
RM17 JC: ≤ 1W
RM35 JA: ≤ 0.6W
Supply
Output Mftrs.
Voltage
Contacts List No.
208 to 440 VAC
2
220 to 480 VAC
208 to 480 VAC
208 to 480 VAC
208 to 480 VAC
120 to 277 VAC
220 to 480 VAC
2
1
1
1
1+1
1+1
2 to 20 A
2 to 500 mA
0.15 to 15 A
Output
Mftrs.
Contacts List No.
1
2
2
RM17JC00MW
RM35JA31MW
RM35JA32MW
1+
5+
10+
Complete cost control, reduced
administration time, visibility of your
spend, flexibility and personalised to
your company’s needs.
farnell.com/ibuy
1+
5+
10+
25+
205-6304●
Order Code
1+
5+
10+
25+
RM35TF30
RM17TA00
RM17TE00
RM17TU00
RM35HZ21FM
RM35UB330
205-6305●
205-6339●
205-6340●
205-6341●
205-6345●
205-6351●
50+
The CM-PVE is used to monitor supply voltages
for over- and undervoltage and phase failure. If
all phases (and the neutral) are present with correct voltage, the output relay energizes after the
start-up delay ts is complete. If the voltage exceeds or falls below the
fixed threshold value or if a phase failure occurs, the tripping delay tv
starts. When timing is complete, the output relay de-energizes. As
soon as the voltage returns to the tolerance range, timing of ts starts.
When timing is complete, the output relay re-energizes automatically.
The yellow LED glows when the output relay is energized.
25+
205-6338●
205-6346●
205-6347●
INTELLIGENT ONLINE BUYING
SYSTEM PROVIDING
Order Code
RM17TG20
CM-PVE
Price Each
Order Code
Price Each
Phase Sequence Monitor
640430
Range
10+ 25+
640462
Ì Selectable memory function
Integrated current transformer
Ì Measurement as true rms value
Choice of action on the output relay
Control status is indicated by a LED
Designed to monitor overcurrent and undercurrent
Measurement
5+
50/60 Hz @ ±10%
5A
-20°C to +50°C
95% at 55°C conforming to IEC 60068-2-30
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
CSA, C-Tick, GL, GOST and UL
100000 cycles
RM35HZ21FM: 40 to 70 Hz
Approvals
Electrical durability
Measurement range
Zelio Control - Current Control Relays
Supply volatge
Supply frequency
Output Current
Operating temperature
Relative humidity
IP degree of protection
Order Code 1+
RM17UAS15 205-6342●
RM17UBE15 205-6344●
RM35UA13MW 205-6350●
Ì The relay monitors:
- The correct sequence of phases L1, L2 and L3
- Phase failure, including in the case of voltage regeneration
- Undervoltage from - 2 to - 20% of the supply voltage
- Overvoltage from 2 to 20% of the supply voltage
- Asymmetry from 5 to 15% of the supply voltage
Ì Monitors its own supply voltage, measured as a true rms value
Ì Control status is indicated by a LED
627501
Output
1
1
2
Price Each
Zelio Control - Phase Control relays
H = 88.8, W = 17.5, D = 60.8mm
Type
40
188-9077●
H = 78, W = 22.5,
D = 78.5mm
Ì
Ì
Ì
Ì
1 n/o contact
Startup and trip delays
Yellow LED for relay status indication
GOST Approved, UL Recognised
Ì Monitoring of three-phase and singlephase supply voltage for overvoltage,
undervoltage and phase loss
Ì Neutral monitoring option
Ì No phase sequence monitoring
Ì Voltage monitoring range: L1-L2-L3: 3 x
320 - 460 V AC. L-N: 185 - 265 V AC
636801
Mftrs.
List No.
Price Each
Order Code
1+
5+
10+
With Neutral Monitoring - Supply / Measuring Voltage = 3 x 320 - 460V ac, 185 - 265V ac
1SVR550870R9400
189-5999●
Without Neutral Monitoring - Supply / Measuring Voltage = 3 x 320 - 460V ac
1SVR550871R9500
189-6000●
2926
farnell.com
Phase Sequence Monitor
element14.com
2927
Sensing & Monitoring Relays
CM-PFE
The CM-PFE is used to monitor three-phase
mains for incorrect phase sequence and phase
failure. If all phases are present with the correct
phase sequence, the output relay energizes after
the start-up delay ts is complete. If a phase failure or a phase sequence error occurs, the tripping delay tv starts. When timing is complete, the output relay de-energizes. The yellow LED glows when the
output relay is energized.
In case of motors which continue running with only two phases, the
CM-PFE detects phase failure if the reverse fed voltage is less than 60
% of the originally applied voltage.
H = 78, W = 22.5,
Ì Monitors 3-Phase supply voltage for inD = 78.5mm
correct phase sequence and phase failÌ Rated supply voltage 110-130V ac
ure
Ì Continuous voltage range covering 3 x
Ì Without delay on "ON"
208-440V, 50/60Hz
Ì 1 c/o contact
Ì GOST Approved, UL Recognised
Ì Yellow LED to indicate state of relay
636800
Mftrs.
Price Each
List No.
Order Code
1SVR550824R9100
189-5998●
1+
5+
Ì Monitoring of voltage (1 and 3 phase), temperature and
current
Ì Variable supply voltage by power module or width range
supply
Ì 2 changeover contacts
Ì Width: 22.5mm
443593
Mftrs.
Price Each
Description
List No.
Order Code
3-Phase Voltage Monitoring
3-Phase Voltage Monitoring
Voltage Monitoring, Multi-Function
Current Monitoring, Multi-Function
Current Monitoring, Multi-Function
G2PM400VSY20
G2PF400VS02
G2UM300VL20
G2IM5AL20
G2IM10AL20
125-0678●
125-0679●
125-0680●
125-0682●
125-0683●
1+
5+
10+
10+
Single-Phase Current Relay
K8AB-AS Series
1 and 3-phase monitoring Relays
The CM-PVE is used to monitor supply voltages
for over and undervoltage and phase failure. If all
phases (and the neutral) are present with correct
voltage, the output relay energizes after the startup delay ts is complete. If the voltage exceeds or falls below the fixed
threshold value or if a phase failure occurs, the tripping delay tv starts.
When timing is complete, the output relay de-energizes. As soon as
the voltage returns to the tolerance range, timing of ts starts. When
timing is complete, the output relay re-energizes automatically. The
yellow LED glows when the output relay is energized.
H = 78, W = 22.5, D = 78.5mm
Ì
Ì
Ì
Ì
Powered by the measuring circuit
1 n/o contact
1 Yellow LED for status indication
GOST Approved, UL Recognised
Measuring
Current
0.1 - 1A AC/DC, 0.5 - 5A AC/DC,
0.8 - 8A AC/DC
413880
Mftrs.
1+
5+
Current Relay, 0.1-8A
10+
With Neutral Monitoring - Supply / Measuring Voltage = 3 x 320-460V ac, 185-265V ac
1SVR550881R9400
189-6001●
24 V ac/dc, 50/60Hz
24 to 240V ac/dc 50/60Hz
0.1 to 20s
0.1 to 20s
1 CO contact
22.5x110x86mm
478174
Range
Hystersis
0.05 to 10 A AC/DC
0.05A to 10A AC/DC
0.01 to 5A
0.01 to 5A
List No.
Price Each
Order Code
1+
5+
10+
Monitoring of DC and AC currents
TRMS measuring principle
Over- or undercurrent monitoring configurable
Precise adjustment by front-face operating
controls
Ì Housing material for highest fire protection
Ì
Ì
Ì
Ì
Ì Digital adjustable, with LCD display
Ì Display of actual value and status messages
Ì Monitoring of single-phase AC currents and DC currents
against the set threshold value of overshoot and undershoot
Ì Screw connection
Ì Automatic/Manual RESET
Ì Monitoring the functionality of electrical loads
Mftrs.
1+
990-0071
Electronic current monitoring relay that
protects single-phase mains (DC or AC)
from over- and undercurrent from 3 mA
to 15 A
1-Phase Current Monitoring Relay
Measuring
Order Code
K8ABAS2200230VAC
Current Monitoring Relays
Without Neutral Monitoring - Supply / Measuring Voltage = 3 x 320-460V ac
1SVR550882R9500
189-6002●
Rated Control Supply Voltage
1AA30
1AW30
Tripping Delay, Freely adjustable
ON-delay, freely adjustable
Contacts
Dimensions (WxHxD)
Price Each
List No.
Price Each
Order Code
Mftrs. List
Order
No.
Code
K8ABAS2200230VAC 990-0071
Mftrs.
636811
List No.
Supply
Voltage
200 - 230VAC
5+
3UG4622-1AW30 431-9898
3UG4622-1AA30 139-0506●
INTELLIGENT ONLINE BUYING
SYSTEM PROVIDING
Complete cost control, reduced
administration time, visibility of your
spend, flexibility and personalised to
your company’s needs.
farnell.com/ibuy
10+
classification UL 94 V-0
Ì Tool-free mounting on DIN rail as well as demounting
Ì 3 LEDs for status indication
Supply Voltage Max Power Consumption Supply Current Contact Configuration
240V
750mW
30mA
SPDT
240V
750mW
30mA
SPDT
240V
750mW
30mA
SPDT
130VAC
2.6VA
24mA
SPDT
240VAC
2.6VA
12mA
SPDT
240V
750mW
30mA
SPDT
130VAC
2.6VA
24mA
SPDT
240VAC
2.6VA
12mA
SPDT
240V
750mW
30mA
DPDT
130VAC
2.6VA
24mA
DPDT
240VAC
2.6VA
12mA
DPDT
240V
750mW
30mA
DPDT
130VAC
2.6VA
24mA
DPDT
240VAC
2.6VA
12mA
DPDT
240V
750mW
30mA
DPDT
240V
750mW
30mA
DPDT
Supply Current
1SVR730760R0400
1SVR730760R0500
1SVR730840R0200
1SVR730841R0200
1SVR730841R1200
1SVR730840R0300
1SVR730841R0300
1SVR730841R1300
1SVR730840R0400
1SVR730841R0400
1SVR730841R1400
1SVR730840R0500
1SVR730841R0500
1SVR730841R1500
1SVR730840R0600
1SVR730840R0700
40
Process Control, Timers & Counters
Ì Monitoring of single and three-phase mains for
phase failure
Ì Device with possibility of neutral monitoring
available
Ì Device with suitability for monitoring singlephase mains available
Automation
Ì Monitor for overcurrents and undercurrents
Ì Manual resetting and automatically resetting supported
by one relay
Ì Startup lock and operating time can be set seperately
Ì One SPDT output relay, 6A @ 250V ac (resistive load)
Ì Switch the output relay between normaly ON and normally OFF operation
Ì Process control signal (4 to 20mA) and commercial CT
input (0 to 1A or 0 to 5A) supported
Ì Relay warning status easily monitoring using LED indicator
Ì Easy wiring with ferrules, 2 x 2.5mm2 solid or 2 x
1.5mm2 standard ferrules
Ì Ideal for current monitoring for industrial heaters and
motors
CM-PVE Series
659462
Mftrs.
Price Each
List No.
Order Code
1SVR730760R0400
1SVR730760R0500
1SVR730840R0200
1SVR730841R0200
1SVR730841R1200
1SVR730840R0300
210-2337●
210-2338●
210-2339●
210-2340●
210-2342●
210-2343●
1+
5+
+
2927
2928
farnell.com
Supply voltage U:
Power consumption:
Monitoring range
Current and Voltage Controls - continued
Current Monitoring Relays - continued
Mftrs.
Price Each
List No.
Order Code
1SVR730841R0300
1SVR730841R1300
1SVR730840R0400
1SVR730841R0400
1SVR730841R1400
1SVR730840R0500
1SVR730841R0500
1SVR730841R1500
1SVR730840R0600
1SVR730840R0700
210-2344●
210-2345●
210-2346●
210-2347●
210-2348●
210-2349●
210-2350●
210-2351●
210-2352●
210-2354●
1+
5+
Hysteresis:
Time delay:
Latch:
Ambient temperature:
Output:
Output rating:
Electrical Life
+
Mftrs. List No.
element14.com
18 to 240VAC
à3VA
1. 20 - 500mA AC / DC
2. 0.2 - 5A AC / DC (for higher AC currents,
use suitable C.T.)
both ranges protected to 10A overload for 60 seconds
Ú2 or 10% of set level
100mS or 1S from fault
Can be enabled or disabled on the front of the relay
-20°C to 60°C
SPDT Relay
[email protected] 250 Vac
≥ 150,000 ops
Price Each
Order Code
M3MCR
1+
5+
248294
10+
100-0075
3 Phase monitoring Relays
CM Series
ABB’s new generation of three-phase
monitoring relays feature additional
functions making the application field
for the devices considerably larger.
Isolating Signal Convertor for Voltage/Current
Ì 3 way isolation for analog signals
Ì Voltage or current inputs and outputs selected via DIP
switch selectable
Ì Small 6.2mm wide housing
Ì High 14 bit resolution
Ì Power supply over bus or terminal connection
Ì Universal mounting foot for Din Rail installation
Voltage: 0-5V, 1-5V, 0-10V, 10-0V, 0-15V, 0-30V
Current: 4-20mA, 0-20mA
Voltage: 0-5V, 1-5V, 0-10V, 10-0V
Current: 4-20mA, 20-4mA, 0-20mA, 20-0mA
Resolution
1mV, 2μA
Accuracy
±0.1% transmission error
Operating Temp.
-20 to 65°C
Isolation
1.5kV (50Hz, 1 min) over digital optocoupler
Power Supply
19.2 to 30V dc, 25mA Max.
Power up to 75 modules over power supply
module WKSUPPLY and 2 slot bus connector
Dimensions (WxHxD)6.2x93.1x102.5mm
Ì
Ì
Ì
Ì
Ì
Ì
Input Ranges
Ì Wide-range operating voltage guarantees world-wide operation
Output Ranges
Automation
443371
Mftrs.
40
Price Each
Description
List No.
Galvanic Isolator Analogue Module
2 Slot Connector
WK109UI0 125-3422●
WKBUS000 125-3424●
Order Code
1+
5+
10+
Process Control, Timers & Counters
Single Phase Current Relay
Ì Adjustable fault delay, 0.1 to 3 seconds
Ì Adjustable start up, delay, 0.1 to 10 seconds
Ì ‘Normal’ or ’inverted’ operation selectable
Ì Adjustable hysteresis
Ì Latching possible
The unit monitors single phase current through a load and
changes state when the adjustable trip level is exceeded. Once
the current drops below this level, minus hysteresis, the relay
changes back unless latching is selected. An adjustable ‘On Delay’ time value allows motor start up currents to be ignored
Contact rating
Monitoring range
Hysteresis
Power consumption
SPDT
AC1 250V ac 10A
DC1 24V dc 10A
AC15 250V ac 6A
Y2: 5-100mA ac/dc
Y3: 50mA-1A AC/DC
Y4: 500mA-10A AC/DC
5-50% of trip level
3VA max.
Overload 1.5A cont. or 5A for 1s
Overload 6A cont. or 17A for 1s
Overload 15A cont. or 55A for 1s
204797
Price Each
Supply Voltage
Supply Voltage
230 Vac
45.150 230V
Order Code
1+
5+
10+
941-9314
Adjustable phase unbalance threshold value
Adjustable ON-delay/OFF-delay time
Dual frequency measuring 50/60 Hz
Powered by the measuring circuit
LED status indication
Phase loss monitoring
Supply Voltage
160 to 300VAC
300 to 500VAC
3 x 380VAC
3 x 400VAC
160 to 300VAC
300 to 500VAC
160 to 300VAC
300 to 500VAC
300 to 500VAC
90 to 170VAC
180 to 280VAC
180 to 280VAC
350 to 580VAC
450 to 720VAC
530 to 820VAC
200 to 500V
Power Consumption
10VA
18VA
18VA
18VA
10VA
18VA
10VA
18VA
4VA
10VA
18VA
4VA
41VA
52VA
59VA
Supply Current
25mA
25mA
25mA
25mA
25mA
25mA
25mA
25mA
5mA
25mA
25mA
5mA
29mA
29mA
29mA
Supply Current
1SVR730774R1300
1SVR730774R3300
1SVR730784R2300
1SVR730784R3300
1SVR730794R1300
1SVR730794R3300
1SVR730884R1300
1SVR730884R3300
1SVR730884R4300
1SVR730885R1300
1SVR730885R3300
1SVR730885R4300
1SVR750487R8300
1SVR750488R8300
1SVR750489R8300
1SVR730824R9300
659454
Mftrs.
Price Each
List No.
Order Code
1SVR730774R1300
1SVR730774R3300
1SVR730784R2300
1SVR730784R3300
1SVR730794R1300
1SVR730794R3300
1SVR730884R1300
1SVR730884R3300
1SVR730884R4300
1SVR730885R1300
1SVR730885R3300
1SVR730885R4300
1SVR750487R8300
1SVR750488R8300
1SVR750489R8300
1SVR730824R9300
210-2310●
210-2311●
210-2312●
210-2313●
210-2314●
210-2315●
210-2317●
210-2318●
210-2319●
210-2320●
210-2321●
210-2322●
210-2323●
210-2324●
210-2325●
210-2326●
1+
5+
+
Multifunction Current Relay - DIN Rail Mounting
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
H=89, W=35, D=59
2928
Detects under or over current condition (selectable)
Automatically selects for AC or DC supply
Multi Voltage supply
Selectable monitoring range
Selectable hysteresis
Selectable time delay
Selectable latching facility
SPDT relay output (8A)
LED indication of supply status
LED indication of "fault" condition
DIN Rail or surface mounting
35mm wide
UL recognised and CUL approved
The first online technical portal for design engineers
Log on, research, refine and design
farnell.com
Voltage Monitoring Relays
element14.com
2929
Phase Failure Relay
Phase Sequence, Under and Over Voltage plus Time Delay
Electronic voltage monitoring relay that
provides reliable monitoring of voltages
as well as detection of phase loss
Ì Monitoring of DC and AC voltages
Ì TRMS measuring principle
Ì One device includes 4 measuring ranges
Ì Over- or undervoltage monitoring configurable
Ì Precise adjustment by front-face operating controls
Ì Housing material for highest fire protection classification
UL 94 V-0
Ì Tool-free mounting on DIN rail as well as demounting
Ì 3 LEDs for status indication
Supply Voltage Max
240V
240V
130VAC
240VAC
240V
130VAC
130VAC
240VAC
240V
Power Consumption
750mW
750mW
2.6VA
2.6VA
750mW
2.6VA
2.6VA
2.6VA
750mW
Contact Configuration
SPDT
SPDT
SPDT
SPDT
DPDT
DPDT
DPDT
DPDT
SPDT
Supply Current
1SVR730750R0400
1SVR730830R0300
1SVR730831R0300
1SVR730831R1300
1SVR730830R0400
1SVR730831R0400
1SVR730830R0500
1SVR730831R1400
1SVR730760R0400
659458
Mftrs.
Price Each
Order Code
1SVR730750R0400
1SVR730830R0300
1SVR730831R0300
1SVR730831R1300
1SVR730830R0400
1SVR730831R0400
1SVR730830R0500
1SVR730831R1400
210-2327●
210-2329●
210-2331●
210-2332●
210-2333●
210-2334●
210-2336●
210-2335●
1+
5+
+
618350
Price Each
Mftrs. List No.
Order Code
1+
5+
10+
17.5mm DIN Width
Automation
List No.
W = 35mm
W = 17.5mm
Ì Monitor own supply and detects if one or more phases exceed the set Under or Over
Voltage trip levels
Ì 3 Wire versions measure phase to phase voltage and 4 Wire versions measures phase
to neutral voltage
Ì Detects incorrect phase sequence, phase loss and neutral loss (4-wire only)
Ì Adjustments for under and over voltage trip level
Ì Adjustment for time delay (from under or over voltage condition)
Ì 1 x SPDT relay output 8A - 17.5mm DIN Rail housing models
Ì 1 x DPDT relay output 8A - 35mm DIN Rail housing models
Ì Intelligent LED indication for supply and relay status
Ì Terminal protection to IP20
Ì Conforms to IEC and CE
3 - Wire
MXPRC/S 400VAC
185-3775●
MXPRT
185-3777●
4 - Wire
M1PRC/S-4W 230VAC
M1PRF-4W 161-300VAC
Battery Voltage Alarm Relay
185-3769●
185-3770●
35mm DIN Width
H=89, W=17.5, D=59
Monitors own DC supply
Detects under voltage condition
Wide supply and monitoring range
Adjustable time delay (from fault)
SPDT relay output (8A)
LED indication of supply and relay status
DIN Rail or surface mounting
17.5mm wide
Supply voltage U:
Power consumption:
Monitoring range
Hysteresis:
Time delay:
Accuracy:
Ambient temperature:
Output:
Output rating:
Electrical Life
12 to 24VDC
à1.8W
9 - 28Vdc
Ú5%
1S to 30S from fault
±10% trip level. ±20% time delay
-20°C to 60°C
SPDT Relay
[email protected] 250 Vac
≥ 150,000 ops
3 - Wire
M3PRT/2 280-520VAC
185-3771●
M3PRC/S/2 400VAC
185-3773●
4 - Wire
M3PRC/S/2-4W 230VAC
M3PRT/2-4W 161-300VAC
185-3774●
185-3772●
40
Phase Failure/Loss Relay
Incorrect Phase Sequence / Rotation
Ì 17.5mm DIN Rail housing
Ì 1 x CO relay output 10A
Ì Conforms to UL, CUL, CSA, IEC and CE
248300
Price Each
Mftrs. List No.
Order Code
M1BVR 12-24V
100-0077
1+
5+
H = 78, W = 45 D = 99mm
10+
185-3778 and 185-3779
185-3780
Ì Incorrect Phase Sequence / Rotation Ì Incorrect Phase Angle - Adjustable
Ì Phase Failure / Loss
Ì Phase Failure / Loss
Ì Under Voltage
Ì Incorrect Phasae Sequence / Rotation
Ì Delay from Fault - Adjustable
Phase Relay
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
H = 89, W = 17.5,
D = 59
17.5mm DIN rail housing
True R.M.S.
Microprocessor based (self checking)
Monitors own supply and detects an Under voltage condition on one or more
phases
Measures phase to phase voltages
Detects incorrect phase sequence and phase loss
Fixed under voltage trip level
Fixed time delay
1 x SPDT relay output 8A
Intelligent LED indication for supply and relay status
Time delay
Operating temperature
Isolation
Frequency Range
Response time
Contact configuration
618352
Price Each
Mftrs. List No.
Order Code
45080 230VAC (400VAC)
45080 400VAC (400VAC)
45095 400VAC
185-3778●
185-3779●
185-3780●
1+
5+
10+
Process Control, Timers & Counters
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Earth Leakage Relay
Type A - Variable
100ms
-20°C to +60°C
Over voltage cat. III
48Hz - 63Hz
50ms
SPDT 204798
Price Each
Order Code
207-6503●
1+
5+
10+
H = 48, W = 48, D = 76mm
H =85, W = 44, D = 63.5mm
Ì
Ì
Ì
Ì
Ì
Ì
Monitors and detects true RMS earth fault currents up to 30A
LED Bar graph provides constant indication of any leakage current
Microprocessor controlled with constant internal monitoring
Adjustable Sensitivity - 30mA to 30A
Adjustable Time Delay - 0 to 10sec
Separate Test and Reset push buttons
2929
2930
farnell.com
Current and Voltage Controls - continued
Under & Over Voltage plus Timer Delay
Earth Leakage Relay - continued
Ì Monitors own single -phase supply
Ì Microprocessor controlled with internal
monitoring (self-checking)
Ì Detects under or over voltage condition
Ì Adjustable under and over voltage trip levels
Ì Adjustable time delay (from under or over voltage condition only)
Ì SPDT relay output (8A)
Ì Intelligent LED indication of supply and relay status
Ì DIN rail or surface mounting
Ì 17.5mm wide
Type A - Variable - continued
Ì
Ì
Ì
Ì
Connection facility for remote Test and Reset push buttons
Toroid open circuit detection
2 Relay outputs - Standard Output and Positive Safety Output
LED indication of Supply status and fault condition after unit has tripped
618337
Mounting
Price Each
Style
Mftrs. List No.
DIN Rail
Panel
ELRM44V30 115/230VAC 185-3734●
ELRP48V30 230VAC
185-3735●
Order Code
1+
5+
element14.com
10+
Accessories - Circular Toroids
70mm Int. Dia. BZCT 070
120mm Int. Dia. BZCT 120
185-3736●
185-3737●
H = 89, W = 17.5, D = 59
Supply/monitoring voltage Un
Power consumption
Impulse withstand voltage
Isolation
Trip levels
Phase Sequence / Failure Relay plus Time Delay
Ì Monitor three phase supply for phase loss, neutral
loss (4 wire version), under voltage and incorrect
phase sequence
Ì Time delay adjustable from 0.2 to 10 seconds to
avoid nuisance tripping
Ì LED indication of supply - extinguished at failure and
power loss
Automation
Voltage range:
Power consumption:
Hysteresis:
Impulse withstand voltage:
Temperature range:
Contact rating:
300V ac to 500V ac
4VA max per phase
2% of set voltage
4kV (1.2/50μS)
-20°C to +60°C
SPDT
AC1 8A/250V ac
DC1 8A/25V dc
AC15 N/O 5A
N/C 3A/250V ac
H=90, W=35, D=59
Type
Order Code
1+
5+
Ambient temperature
Output
Output rating
381713
Price Each
204799
Relay
Relay - 4 wire
Hysteresis
Time delay
Electrical life
Housing (UL94-V0)
Weight
Terminal conductor size
Mftrs. List No.
Order Code
10+
941-9241
941-9250
1+
5+
10+
210-0006●
851-9480
MXCVR 230VAC
M1CVR 115V
Price Each
40
115, 230V ac 48 - 63Hz
4VA Max.
4kV (1.2/50μS)
Over voltage Cat. III (IEC 60664)
Under (fixed): 70% of Un
Under (adjustable): 75 - 95% of Un
Over (adjustable): 105 - 125% of Un
2% (factory set)
0.2 - 10S (± 5%) - from under or over voltage condition
Note: Time delay is cancelled and relay de-energises if supply
is allowed to fall below the "fixed" trip level.
100mS - from loss of supply
1S - from application of supply (power on delay)
-20 to +60°C
SPDT relay
AC1 - 250V ac 8A (2000VA)
AC15 - 250V ac 5A (no), 3A (nc)
DC1 - 25V dc 8A (200W)
≥150,000 ops @ rated load
Orange flame retardant
70g
≤ 2x 2.5mm2 solid or stranded
Monitoring Relay
1-Phase, AC Over Current
Process Control, Timers & Counters
Phase Sequence/Failure Relays
Two devices for monitoring three phase
power supplies. The orange ABS housings conform to the dimensional requirements of DIN43880 and can either be
mounted on symmetric 35mm DIN rail
or screw mounted, using 2xM4 screws.
The phase sequence/failure relay is energised when all three phases are present and in the correct rotation, it is released on failure of any phase. A potentiometer on the module allows the trip
Phase sequence/failure relay
Three phase indicator voltage to be set and there are LED’s for
H=90, W=35, D=59
H=90, W=35, D=59 power supply and when all phases are
correct.
The three phase indicator module shows phase presence by means of a red LED for each
energised phase. A green LED is illuminated when all phases are present and in sequence,
another red LED indicates breakdown of phase sequence.
Phase Sequence/Failure Relay
Three Phase Indicator
Temperature range
250V ac 8A
300 to 500V ac phase to phase
48 to 63Hz
-20°C to +60°C
—
300 to 500V phase to phase
48 to 63Hz
-20°C to +60°C
Approvals
Terminal protection
Flame retard. rating
CSA / UL Recognised
IP20
UL94V-0
CSA / UL Recognised
IP20
UL94V-0
Contact rating max
Supply voltage monitored
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
H = 81, W = 17.5, D = 67.2mm
Small current monitoring relay with built-in current transformer, adjustable setpoint and integrated solid state output. Self-powered and 2-wire connection for easy use.
12 mm hole for insulated current carrying wire makes it suitable for most applications. Designed for mounting on DIN-rail, the 17.5 mm wide housing is suitable both for back and
front panel mounting.
609861
Mftrs.
Current Range
List No.
Order Code
DIA53S72420A
182-4777●
Order Code
1+
5+
10+
DC Under Voltage
Measuring if power supply is below the set level
Measures on own power supply
Measuring ranges: 8-28V dc
Adjustable hysteresis: 4 to 50%
Output: 5A SPDT NE relay
For mounting on DIN rail in accordance with DIN/EN 50
022
Ì 17.5mm housing (DIN 43880)
Ì LED indication for relay and power supply ON
Ì Dimensions: W=17.5mm H=81.5mm D=67mm
Ì
Ì
Ì
Ì
Ì
Ì
25+
941-9217
941-9225
Input
Output
Hysteresis
Operating Temperature
TROUBLESHOOTING TIPS
12 to 24VDC
Relay, SPDT, 5A @ 250VAC
4 - 50%
-20 to 60°C, R.H. <95%
Chat online to one of our
technical engineers at farnell.com
346932
Price Each
Mftrs. List No.
DUA52C724
2930
1+
Monitoring Relay
204814
Sequence/ failure relay
Three phase indicator
Price Each
DIA53
Price Each
Description
2-Wire connection
Self powered
2 - 20A ac Input range
Adjustable set-point
Normally open, 100mA output
LED Indication of output status
DIN Rail mounting in accordance with DIN / EN 50 022
17.5mm DIN-Rail housing (DIN 43880)
Order Code
733-0782
1+
5+
10+
25+
farnell.com
Temperature Control Relays
Temperature Monitor Relay
K8AB-TH
Ì Excessive temperature increases can be prevented and abnormal temperatures can be monitored
Ì Temperature monitoring in slim design with a width of just
22.5mm
Ì Multi input support for both thermocouple or PT100
Ì Multi-input support for thermocouple or Pt100 sensor input
Ì Selectable output relay: Non-fail safe/fail safe
Ì Alarm status identification with LED indicator
Ì
Ì
Ì
Ì
Ì
Ì
Ì
element14.com
2931
3 way isolation of thermocouples type S, T, J, N, K, E, R and B
Settable alarm threshold/hysteresis
Outputs selected via DIP switch settings
Small 6.2mm wide housing
High 14 bit resolution
Power supply over bus or terminal connection
Universal mounting foot for Din Rail installation
443356
Price Each
Description
Mftrs. List No.
Glavanic Isolator Module for
Thermocouples
2 Slot Connector
WK109TC0
WKBUS000
Order Code
1+
5+
10+
125-3421●
125-3424●
Temperature Transmitter
Input Temperature
Type Setting Range
0°C to +399°C°C/°F
0°C to +399°C°C/°F
0°C to +1700°C°C
0 to 3200°F
Setting
Unit
1°C/°F
1°C/°F
10°C/°F
Supply
Voltage
100 to 240VAC
24VAC/dc
100 to 240VAC
Mftrs.
List No.
K8AB-TH11S AC100-240
K8AB-TH11S AC/DC24
K8AB-TH12S AC100-240
Order Code
134-3840
134-3842
2 Wire - DIN Rail Mount
Temperature sensor inputs
2 Wire (4 - 20mA) output
Simple push button configuration
Advanced user configuration with
56 pre-set temperature ranges
Ì User push button trim
Ì Programmable burnout
Ì
Ì
Ì
Ì
134-3843
462327
Price Each
Mftrs. List No.
Order Code
K8AB-TH11S AC100-240
K8AB-TH11S AC/DC24
K8AB-TH12S AC100-240
134-3840●
134-3842●
134-3843●
1+
5+
10+
5
WARRANTY
YEARS
Motor Protection Relay - Thermistor
H = 75, W = 12.5, D = 60mm
535088
Price Each
Input Type
Mftrs. List No.
Order Code
SEM213P
SEM213TC
170-6806●
170-6807●
PT100
Thermocouple
Thermostat Relay
Ì Thermostat relay for 2/3 wire Pt-100 probe
Ì -50 to 300°C in two ranges
Ì Adjustable setpoints and hysteresis on the front
panel
Ì Inversion (inv) of relay operation on connection
of jumper
Ì LED indication on probe failure
Ì Analogue outputs for setpoints and measured
temperature
636797
Mftrs.
Price Each
List No.
Order Code
1SVR550800R9300
189-5997●
1+
5+
10+
H=80, D=104, W=22.5
Isolating Signal Converter for Pt100/Pt1000
Input Ranges
Output Ranges
Accuracy
Operating Temperature
Power Supply
Dimensions (WxHxD)
Ì 3 way isolation of Pt100 or Pt1000 resistant thermometers
Ì Connection by 2, 3 or 4 wire technique
Ì Outputs selected via DIP switch settings
Ì Small 6.2mm wide housing
Pt100: Range -150 to 650°C, minimum span 50°C
Pt1000: Range -200 to 210°C, minimum span 30°C
Voltage: 0-5V, 1-5V, 0-10V, 10-0V
Current: 4-20mA, 20-4mA, 0-20mA, 20-0mA
±0.1% transmission error max.
-20 to 65°C
19.2 to 30V dc, 25mA Max.
Power up to 75 modules over power supply
module WKSUPPLY and 2 slot bus connector
6.2x93.1x102.5mm
Ì High 14 bit resolution
Ì Power supply over bus or terminal
connection
Ì Universal mounting foor for Din Rail
installation
443353
Mftrs.
Description
List No.
Galvanic Isolator Module for Pt100 WK109PT0
Galvanic Isolator Module for Pt1000 WK109PT1
2 Slot Connector
WKBUS000
Price Each
Order Code
1+
5+
10+
125-3419●
125-3420●
125-3424●
Isolating Signal Converter for Thermocouples
Input Ranges
Thermocouples type S, T, J, N, K, E, R, B: Minimum
span 100°C
Output Ranges
Voltage: 0-5V, 1-5V, 0-10V, 10-0V
Current: 4-20mA, 20-4mA, 0-20mA, 20-0mA
Accuracy
±0.1% transmission error max.
Operating Temperature -20 to 65°C
Isolation
1.5kV (50Hz, 1 min) over digital optocoupler
Digital Output
Static alarm output, nominal voltage 24V ac/dc, current 60mA
Power Supply
19.2 to 30V dc, 25mA Max.
Power up to 75 modules over power supply
module WKSUPPLY and 2 slot bus connector
Dimensions (WxHxD) 6.2x93.1x102.5mm
1+
Input Signal
Output Signal
-50-50°C
-50°C
0-100°C
100-200°C
200-300°C
Relay SPDT 8A/240V ac
0-10V dc (relative to setpoint)
0-10V dc (relative to temperature)
231512
Price Each
Supply Voltage
Mftrs. List No.
230VAC/24V ac
MXT-10.230
Order Code
1+
5+
10+
25+
723-3670
Universal Signal Conditioner
Programmable Output - DIN Rail Mount
This new generation of signal conditioner has been designed to accept most common process and temperature
sensor inputs and provide the user with a programmable
current or voltage output signal plus dual relays with a programmable delay function. 3 way isolation is provided and all temperature
ranges are linear to temperature. Both
WARRANTY
input and output loop excitation is proYEARS
vided as well as a fully universal power
supply.
A USB interface is fitted for quick and
easy configuration. Connect a standard USB cable between the device and a PC and using the configuration
software the PC will automatically upload the existing conH = 106, W = 22.5, D = 120mm figuration data and then guide the user through any changes that are required. No external power for the device is required during this process as the
power is supplied via the PC USB interface.
40
Process Control, Timers & Counters
This relay operates with a rated control supply
voltage of 110-130 V AC and has a 1 n/o output
contact rated at 250 V / 4 A. It features one sensor circuit for monitoring of PTC temperature sensors or bimetals. This relay offers automatic reset and works according
to the closed-circuit principle.
The CM-MSE thermistor motor protection relay is used to control motors equipped with PTC temperature sensors. The PTC temperature
sensors are incorporated in the motor windings to measure the motor
heating. This enables direct control and evaluation of the following operating conditions:
H = 78, W = 22.5, Ì Heavy duty starting
Ì Insufficient cooling
D = 78.5mm
Ì Increased switching frequency Ì Break operation
Ì Single-phase operation
Ì Unbalance
Ì High ambient temperature
Automation
CM-MSE
5
Ì Simple configuration via USB port
Ì Universal RTD, Thermocouple, mV, V, mA
and potentiometer inputs
Ì Isolated universal voltage or current output
Ì Dual change over relay trip outputs
Ì Universal AC DC power supply, 3 port
isolation
Ì User Trim and User Configuration
push buttons
535091
Input Type
Mftrs. List No.
Order Code
Price Each
1+
Type
List No.
Order Code
RTD, T/C, Potentiometer, Current or Voltage
USB Cable
SEM1700
88732-8602
170-6808●
122-1071●
2931
2932
farnell.com
Temperature Control Relays - continued
Universal Transmitter
Current or Voltage Output - DIN Rail Mount
5
WARRANTY
Ì Process and Temperature Sensor
YEARS
inputs
Ì 2 Wire (4 - 20mA) output and 3
Wire (Programmable) output versions
Ì Simple push button configuration
Ì Advanced user configuration with 56 pre-set temperature ranges
Ì USB Configuration port
Ì User push button trim
Ì Programmable burnout
element14.com
Probe
Mftrs.
Length
List No.
Order Code
Price Each
100mm
150mm
HTR201/2/100
HTR201/2/150
186-6764●
186-6765●
USB-CONFIG-MKII
186-6766●
1+
5+
Accessories
USB Powered Configurator Kit
Universal Temperature Transmitter
SEM710 with Display
Ì Simple configuration via USB port
Ì Isolated PT100, thermocouple input
Ì Display - Temperature in °C / °F
or Output Drive in mA
Ì Push-button user trim
Ì (4 to 20) mA two wire output
Ì 24V dc supply voltage
H = 90, W = 17.5, D = 56.4mm
535093
5
WARRANTY
YEARS
Price Each
Output Type
Mftrs. List
No.
(4 - 20mA)
0V to 10V, 0V to 5V, 2V to 10V, 1V to 5V and 0V to 1V
USB Cable
Order Code
1+
H = 21.5, Dia.(overall) = 74.8, Dia. = 66.25mm
The SEM710 is a head mounted temperature transmitter with display feature. It has been
designed to accept most common temperature sensor inputs and provide the user with a
standard two wire (4 to 20) mA output signal. Isolation is provided between input and output and all temperature ranges are linear to temperature. The addition of a display provides
the user with instant information of the loop condition at the point of measurement. Designed for ease of use, the latest USB interface is fitted for quick and easy configuration.
Just connect a standard USB cable between the SEM710 and a PC. Using the free configuration software, the PC will automatically upload the existing configuration data and guide
the user through any changes required. To further help save time, the SEM710 does not
need to be wired to a power supply during the configuration process, it is powered via the
USB interface from the PC.
SEM1610 170-6811●
SEM1620 170-6812●
88732-8602 122-1071●
DIN Rail Temperature Transmitter
SEM1603 Series
Automation
Ì Configured by using the USB Port Powered
Configurator
Ì PT100 or Thermocouple / mV
Ì Isolated input
Ì Input linear to temperature
Ì (4 to 20) mA two wire output
Ì 24V dc powered
40
622571
5
Mftrs.
WARRANTY
YEARS
H = 90, W = 17.5, D = 56.4mm
Process Control, Timers & Counters
The SEM1603 series is a DIN rail mounted temperature transmitter from Status Instruments. The range consists of two versions, the SEM1603P accepts PT100 inputs, the
SEM1603TC accepts seven common thermocouple types plus mV input. Designed for
ease of use, this range is configured with the USB port powered configuration module. The
module interfaces a PC USB port to the SEM1603, using the (4 to 20) mA loop to communicate. Using the free configuration software, you will be able to read the current configuration data, and then perform any changes you wish to make to the configuration. To further
help save time, the SEM1603 and configuration module do not need to be wired to a power
supply during the configuration process, both are powered by the USB interface on the PC.
622563
Input
Mftrs.
Price Each
Type
List No.
Order Code
PT100
Thermocouple
SEM1603/P
SEM1603/TC
186-6762●
186-6763●
Accessories
USB Powered Configurator Kit
USB-CONFIG-MKII
186-6766●
1+
5+
List No.
Order Code
Without Probe
SEM710/4/C/2420
186-6767●
1+
5+
Wireless Signal Conditioner
WRX900 Series DIN Rail Receiver
Ì Receives signals for up to 16 WTX700
Transmitters
Ì ISM BAND 868.4 MHz for European use
Ì Up to 300 m range
Ì Programmable current or voltage and 2
relay output
Ì RS485 Mobus output
Ì Push-button or PC programmable
Ì LCD Display
H(Body) = 110, W = 22.5, Ì Low transmitter battery warning / alarm
5
WARRANTY
YEARS
D = 124.3mm
HTR201 Series
5
WARRANTY
YEARS
H = 52, W = 60, D = 48.8mm
The HTR200 is a cost effective SMART transmitter integrated into an MAA type connection
head that accepts resistance signals including RTD sensors and converts them to a standard industrial (4 to 20) mA transmission signal over a user programmed range. There are
two versions available with either a 100mm or a 150mm probe fitted. Its small size (52mm
swing diameter), allows for installations where space is critical. Temperature probes are
sold separately and style 1 and 2 are the most popular with this product. A flexible approach has been taken with this design in that, the standard product will accept over 30 resistance sensors, including Pt100, Pt500 Pt1000, Ni100, Ni1000 and variable resistance.
The design also allows for custom sensors to be accommodated. It is also possible to
generate your own linearisation curve for resistance or slide wire inputs. PC configuration
allows the user to select Sensor type, Range, Units and error signal without requiring calibration equipment. Configuration is performed quickly using our USB port driven configurator by simply connecting two clips to the HTR200 loop terminals and following the software instructions. Additionally, the user may read live process data when connected to the
PC, allowing for sensor offset calibration, where the user can enter an offset value to correct for any sensor offset.
622564
2932
Type
The WRX900 receiver is used together with the WTX700 in head temperature transmitter
for wireless temperature measurement. The product converts the measured temperature
values received into isolated current or voltage signals (0) 4 to 20 mA, (0 to 10V) as well
as making them available via a digital RS485 interface. The WRX900 will accept wireless
signals from up to 16 WTX700 in head transmitters. Any one of the temperature values received can be linked to any one of the analogue or relay outputs and all are available via
the RS485 digital interface. The product operates using the ISM (Industrial Scientific and
Medical) band of 868.4 MHz. This frequency is virtually insensitive to external interferences
and allows transmission even in a harsh industrial environment. The antenna screws into
the top of the DIN rail module but for use in cabinets or to gain a better signal. Programming is possible by using the Wireless configuration kit. Alternatively it is possible to programme the product manually using the push buttons and information on the LCD screen.
SMART Head Temperature Transmitter
Ì MAA Type aluminium head with integral
transmitter
Ì Light weight and robust design
Ì 52mm Swing diameter
Ì RTD, Slide Wire or Resistance inputs
Ì User linearisation
Ì PC Programmable
Ì (4 to 20) mA Output
Ì 8 to 30V dc Supply
Price Each
622540
Supply
Mftrs.
Voltage
List No.
Price Each
Order Code
For Analogue output types - 4 x Current or Voltage signals
240VAC
WRX900/04/S1/A
186-6751●
24VDC
186-6752●
WRX900/04/S2/A
1+
5+
For Relay output types - 2 x NO (Configurable as NC) 3A @ 230V ac resistive load
240VAC
WRX900/22/S1/A
186-6753●
24VDC
WRX900/22/S2/A
186-6754●
Accessories
PC Interface with USB/TTL Converter WLESS/CNFG/KIT
186-6761●
Wireless in-head Temperature Transmitters
WRX700 Series
Ì ISM Band 868.4MHz for European use
Ì RTD, Thermocouple, Slidewire or mV Inputs
Ì 3.6V, AA size, lithium battery powered
Ì 300m Line of Sight range
Ì Supplied fitted with Status Instruments Head
5
WARRANTY
YEARS
farnell.com
The WTX700 series in head temperature transmitter is a new generation of wireless temperature measurement solutions from Status Instruments. It has been designed to accept
most common temperature sensors including those from RTD and thermocouple sensors
as well as slidewire and mV signals. The measured value is transmitted to the DIN Rail
mounted base station (WRX900), this can accept signals from up to 16 WTX700 transmitters. A 3.6 V Lithium battery is provided for the transmitter power supply and is fitted in a
specially designed antenna housing which screws into the cable entry of the connecting
head. The connecting head is supplied with the product and can be sensor mounted. This
is particularly useful when used with a flying lead sensor such as our style 4 sensor type
and allows for a wider range of applications. The measured signal is transmitted on the
ISM band (Industrial Scientific and Medical Band) of 868.4 MHz. This frequency is virtually
insensitive to external interferences and allows transmission even in a harsh industrial environment. The maximum open air range is 300 m. Configuration is carried out by using the
Wireless Configuration kit. This allows configuration of all parameters including transmitter
address, transmission interval, sensor type etc.
622558
Input
Mftrs.
Price Each
Style
List No.
Order Code
Without Probe
M24 Process Entry
WTX700/SCH11
186-6755●
M16 Cable Entry
WTX700/SCH4/B
186-6756●
1+
5+
M24 Process Entry
M16 Sensor Cable Entry
WTX700/SCH11/2/150 186-6757●
WTX700/SCH4/B/4/150 186-6759●
Accessories
PC Interface with USB/TTL Converter WLESS/CNFG/KIT
186-6761●
Trip Amplifier
Dual Relay Outputs - DIN Rail Mount
Type EM21 72D - Removable Display Unit
Three-phase energy meter with removable front LCD
display unit. The same unit can be used either as a
DIN-rail mounting or a panel mounting energy meter.
This general purpose three-phase energy meter is
suitable for both active and reactive energy metering
for cost allocation but also for main electrical parameter measurement and retransmission (transducer
H = 71.7, W = 71.5, D = 64.6mm
function). Housing for DIN-Rail mounting with IP50
(front) protection degree. Current measurements carried out by means of external current
transformers and voltage measurements carried out either by means of direct connection
or by means of potential transformers. The unit is provided, as standard, with a pulsating
output for active energy retransmission. In addition a 2-wire RS485 communication port
version is available.
Retrofit version with a miniature splitcore current transformer allows quick and easy installation
Class B (kWh) according to EN50470-3
Class 1 (kWh) according to EN62053-21
Class 2 (kvarh) according to EN62053-23
Accuracy ±0.5 RDG (current/voltage)
Instantaneous variables readout: 3 DGT
Energies readout: 6+1 DGT
System variables: W, var, PF, Hz, Phase-sequence.
Single phase variables: VLL, VLN, A, PF
Energy measurements: total kWh and kvarh
TRMS measurements of distorted sine waves (voltages/currents)
Self power supply
Protection degree (front): IP50
Application adaptable display and programming procedure (Easyprog function)
Easy connections management
Detachable display
Multi-use housing: for both DIN-rail and panel mounting applications
609862
Price Each
Current Output 1
Output 2 Mftrs. List No.
Single static (opto-MOSFET)None EM21-72D.AV5.3.X.0.XX
Single static (opto-MOSFET)RS485 EM21-72D.AV5.3.X.0.SX
Retrofit Versions
90A Single static (opto-MOSFET)RS485 EM2172RVV23X0SX
150A Single static (opto-MOSFET)RS485 EM2172RVV33X0SX
250A Single static (opto-MOSFET)RS485 EM2172RVV53X0SX
Order Code
1+
182-4774●
182-4775●
194-7810●
194-7811●
194-7812●
Automation
Ì Process and Temperature Sensor
inputs
Ì Isolated input
Ì Dual 250V ac 1A Relay, change
over contact outputs
Ì Relays isolated from each other
Ì Simple configuration via USB port
Ì 24V dc supply
2933
3-Phase Energy Management Meter
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
With Probe
element14.com
40
H = 90, W = 17.5, D = 56.4mm
Type
2
USB Cable
Mftrs. List No.
Order Code
Price Each
List No.
Order Code
1+
SEM1630
88732-8602
170-6813●
122-1071●
3-Phase Energy Management Meter
Type EM24 DIN - Energy Analyser
Energy - Meter
efergy E2 Energy Monitoring Meter
Wireless
Display - H = 185, W = 185, D = 24mm
The Efergy 2 + Elink wireless electricity display device is a wireless energy monitor that
displays at a glance how much electricity your equipment is using. Elink technology allows
data to be transferred to your computer to help you spot money saving opportunities and
to assist with the reduction of carbon footprints.
You can view instant, average and historical information (daily, weekly and monthly totals
are stored in the memory) on the portable display unit. Download stored data to your PC
for more detailed analysis and see your energy use clearly displayed in bar charts and line
graphs.
Radiated frequency 433.52MHz with a range of 40 to 70m depending on the environment.
The Portable Display Unit and the Transmitter/Sender Unit require 3 X AAA batteries each
(6 in total). Lithium or rechargeable cells are recommended.
Ì Simple and quick to install and use
Ì PC connectivity, sensor, transmitter/sender and Elink energy monitoring software CD
included
Ì Program up to 4 tariffs - set start/end times and p/kWhr to match your supply
Ì Instant, Average and Historical data shown on portable wireless display
549871
Price Each
Mftrs. List No.
Order Code
EFERGY E2-METER
177-4541●
1+
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Three-phase energy analyzer with
built-in configuration joystick and LCD
data displaying; particularly indicated
for active and reactive energy metering and for cost allocation. Housing
for DIN-rail mounting with IP50 (front) protection degree.
Direct connection up to 65A and by means of external
current and potential transformers. Moreover the meter
can be provided with digital outputs that can be either for
pulse proportional to the active and reactive energy being
measured or for alarm outputs. In alternative the RS485
communication port and 3 digital inputs or Dupline port
and 3 digital inputs are available as an option.
Class 1 (kWh) according to EN62053-21
Class B (kWh) according to EN50470-3
Class 2 (kvarh) according to EN62053-23
Accuracy ±0.5 RDG (current/voltage)
Energy analyzer
Instantaneous variables readout: 4 DGT
Energies/gas/water readout: 7+1 DGT
System variables: VLL, VLN, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd
max, var, PF, Hz, Phase-sequence.
Single phase variables: VLL, VLN, A, VA, W, var, PF
Energy measurements: total and partial kWh and kvarh or based on 4 different tariffs;
single phase measurements
Gas, cold water, hot water, kWh remote heating measurements
Hour counter (6+2 DGT)
TRMS measurements of distorted sine waves (voltages/currents)
Dimensions: 4-DIN modules
Protection degree (front): IP50
Application adaptable display and programming procedure
Easy connections management
Process Control, Timers & Counters
535095
Output Type
659687
Price Each
Type
Mftrs. List No.
Order Code
CT Connection
3 Digital Inputs
EM24-DIN.AV5.3D.IS.P
194-7814●
Dual Open Collector
EM24-DIN.AV5.3D.02.P
194-7815●
Direct Connection
3 Digital Inputs
Dual Open Collector
EM24-DIN.AV9.3X.IS.P
EM24-DIN.AV9.3X.02.P
194-7816●
194-7817●
1+
5+
2933
2934
farnell.com
Process Relays
element14.com
Analogue Signal Conditioners
Thermostat Relay
3 Way Isolating Amplifier - Single Channel
Analogue Current - 4 to 20mA
Ì Thermostat relay for 2/3 wire Pt-100 probe
Ì -50 to 300°C in two ranges
Ì Adjustable setpoints and hysteresis on the front
panel
Ì Inversion (inv) of relay operation on connection
of jumper
Ì LED indication on probe failure
Ì Analogue outputs for setpoints and measured
temperature
H=80, D=104, W=22,5
pro519/205786
Mftrs.
Price Each
Supply Voltage
List No.
Order Code
230V ac/24V ac
MXT-10.230
723-3670
1+
5+
10+
25+
Automation
Ì Threshold relay for process signal
Ì Relay output
Ì Adjustable setpoints and hysteresis on the front
panel
Ì Hysteresis adjustable: ±0.5-20%
Ì Inversion (inv) of relay function on attachment
of jumper
Ì Automatic locking (latch) on connection of
jumper
Input Signal
0-5Vdc
0-10Vdc
-10 - +10Vdc
0-20mA dc
4-20mA
Output Signal
Relay SPDT 8A/240Vac
205776
Price Each
40
Supply Voltage
Mftrs. List No.
Order Code
24VDC dc
230V ac/24V ac
PXL-10.924
PXL-10.230
723-3334
723-3358
535123
Price Each
Threshold Relays
H=80, D=104, W=22.5
Ì DIN rail mounting in accordance with EN 50 022
Ì M3 screw terminals - Solid/flexible wires 0.2 - 2.5mm
Ì Supply voltage 20V dc to 30V dc
Ì Single channel current signals 0(4) to 20 mA
Ì UL Recognised
This 3-way isolator amplifier provides electrical isolation
and processing of analog 4 to 20 mA standard current signals. The module input and output are supplied via integrated DC/DC converters which are electrically isolated
from the mains. The device ensures the safe decoupling of
a sensor circuit from the evaluation circuit and also prevents the negative effects of several sensor circuits conH = 99, W = 12.5, D = 114.5mm nected with one another.
1+
5+
10+
25+
Input and Output Currents
Mftrs. List No.
Order Code
Current - Isolated - Current
MCR-C-1-1-00-DC
170-6195●
1+
3 Way Isolating Amplifier - Single Channel
Configurable Current and voltage input and output
Ì
Ì
Ì
Ì
Ì
Ì
DIN rail mounting in accordance with EN 50 022
M3 screw terminals - Solid/flexible wires 0.2 - 2.5mm
Supply voltage 18V dc to 30V dc
Unconfigured
Configurable inputs and outputs via DIP switches
UL Recognised
This 3-way isolator amplifier is used to provide electrical
isolation and conversion of analog signals. The module input and output are supplied via integrated DC/DC converters which are electrically isolated from the mains. The required auxiliary voltage is indicated via a green power LED.
This clearly indicates whether or not auxiliary voltage is
H = 99, W = 17.5, D = 114.5mm available. 3-way isolation enables the universal use of
modules both locally and close to the control system for signal conversion and electrical
isolation, as well as on the transmission path for jumpering high load resistors. Conversion
is carried out by an inductive transmission method. In addition a filter connected downstream of the transmitter reducing possible interference.
535127
Process Control, Timers & Counters
Price Each
Process Signal Converter
Ì Linear process signal converter
Ì Input selection via switch on the front panel
Ì Offset/gain (zero/span) adjustable on the front
panel ±0.5%
Input Signal
0-5Vdc
0-10Vdc
-10 - +10Vdc
0-20mA dc
4-20mA
Output Signal
4-20mA dc (max. 500 Ohm)
0-20mA dc (max. 500 Ohm)
0-10Vdc (via internal 500 Ohm shunt)
Input and Output Circuits
Mftrs. List No.
Order Code
- Isolated -
MCR-C-UI-UI-DCI-NC
170-6197●
Programmable Universal Frequency
Transducer
3-Way Isolated
Ì DIN rail mounting in accordance with EN 50 022
Ì Suitable for Class 1 Division 2, Groups A, B, C and D
Hazardous locations
Ì Also suitable for non-hazardous applications
Ì Programmable using membrane keypad
Ì LCD display of the input or output signal
Ì Displays and converts frequencies from 0.1 Hz to 120
kHz
Ì Output voltage 0-10V / 10-0V, 0-5V / 5-0V or
Ì Output current 0-20 mA / 20-0 mA
Ì Supply 20 - 30V dc
Ì UL Recognised
H=80, D=104, W=22.5
205778
Price Each
Supply Voltage
24Vdc
230Vac
Mftrs. List No.
Order Code
PXU-20.924
PXU-20.230
723-3395
723-3425
1+
5+
10+
1+
25+
Process Timer
H = 75, W = 45, D = 110mm
Multifunction Timer
Ì Multifunction timer with 5 functions
and 4 time ranges
Ì The function and time range are selectable via 2 front
mounted rotary switches
Ì Time ranges cover 0.6sec-60min or 0.6min-60hrs
Ì Can be directly connected to the supply in the range of
10.5-265Vac/dc
Ì Single or double relay output with LED induction of energised relay
Ì 11-pole plug-mounting
The frequency transducer module accepts frequencies between 0.1 Hz and 120 kHz. The
input frequency can be easily selected within this range and displayed on the front face of
the module.
All common frequency signal (2, 3 and 4 wire) can be accepted at the input. The input options are as follows:
NAMUR sensors, Frequency generators, Dry contacts and Incremental encoder signals.
In addition to the analog output a transistor switching output (For alarm processing) is
available. The input frequencies (lower and upper range) can be programmed in via the
membrane keypad, as revolutions per minute (rpm) or as Hz. Analog voltage and current
inputs can also be converted and isolated. The LC Display can show both input and output
measurement values.
535131
Functions
On delay
Release delay
On pulse (without control switch)
On pulse (with control switch)
Symmetrical recycler with pause start
Time Ranges
0.6 sec - 60 min
0.6 sec - 60 hrs
(Time range sub-divided in 4)
Supply Voltage
10.5-265VAC/ dc
Price Each
205787
Price Each
2934
Output
Mftrs. List No.
Order Code
SPDT
DPDT
XMW-S1
XMW-S2
723-3681
723-3693
1+
5+
10+
25+
Mftrs. List No.
Order Code
MCR-F-UI-DC
170-6198●
1+
farnell.com
Signal Multiplier
element14.com
2935
Voltage Transducer
4-way Isolation
3-Way Isolated - DC Voltages
Ì Signal conversion and amplification
Ì DIN rail mounting
Ì Suitable for Class 1 Division 2, Groups A, B, C and D
Hazardous locations
Ì Also suitable for non-hazardous applications
Ì Configurable inputs and outputs
Ì Adjustable signal combinations
Ì Supply 20 - 30V dc
Ì M3 screw terminals - Solid/flexible wires 0.2 - 2.5mm
Ì UL Recognosed
H = 99, W = 17.5, D = 114.5mm
This module is used to multiply and electrically isolate analog signals.
The inputs, outputs and power supply are electrically isolated from one another (4 - Way
isolation). This enables the unit to be used for electrical isolation, signal conversion and
amplification both locally and close to the control system. The auxiliary voltage required is
indicated by a green power LED.
DIP switches can be used to switch between a signal a signal selected within the limits of
the order key or the for the fixed signal conversions.
535143
Price Each
Input and Output Currents
Mftrs. List No.
Order Code
Isolated
MCR-FL-C-UI-2UI-DCI-NC
170-6199●
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
The voltage transducer measures DC voltages in ranges
from 0 - ±10V to 0 - 660V and converts them to standardized analog signals. DC voltages with both negative and
positive polarity can be processed.
H = 99, W = 22.5, D = 114.5mm The input voltage ranges listed at the input terminal block
can be varied by ±20% using a calibrated potentiometer.
The transducer is calibrated by default to 0 to ±24V input and 0 to ±10V output and is
ready for operation when delivered. To use the device with other input or output variables,
carry out a ZERO / SPAN adjustment using the potentiometer on the front.
535216
Price Each
Mftrs. List No.
Order Code
MCR-VDC-UI-B-DC
170-6203●
3 Way Isolating Amplifier
Standard Signal
3-way isolation
Safe isolation in accordance with EN 61 0100
DIN rail mounting
Configurable inputs and outputs
Adjustable cut-off frequency ≤10 Hz / 10 kHz
Supply 20 - 253V ac/dc
M3 screw terminals - Solid/flexible wires 0.2 - 2.5mm
UL Recognosed
535145
H = 93.1, W = 6.2, D = 102.5mm
535217
Mftrs. List No.
Order Code
MINI MCR-SL-1-1
170-6204●
Mftrs. List No.
Order Code
Isolated
MCR-FL-C-UI-UI-DCI-24/230
170-6200●
Temperature Transducer - Thermocouple
MCR temperature transducer for J or K type thermocouples, can be configured via DIP switches, with
screw connection, not pre-configured
1+
Input
Output - Signal Current
Output - Singal Voltage
Supply
Operating Temperature Range
Approvals
Programmable Current Transducer
3-Way Isolated - 55 Amp.
Ì DIN rail mounting
Ì Suitable for Class 1 Division 2, Groups A, B, C and D
Hazardous locations
Ì Also suitable for non-hazardous applications
Ì Progressive adjustment of measuring range
Ì True rms value measurement
Ì 3-way electrical isolation according to EN 61010
Ì Unconfigured with through connection
Ì Supply voltage 20 to 30V dc
Ì CE Approved, UL Recognised
605492
Rrice Each
Mftrs. List No.
Best.-Nr.
MINI MCR-SL-TC-UI-NC
+
+
Temperature Transducer - PT100
MCR temperature transducer for Pt 100 temperature
sensors, configured via DIP switch, with screw connection, not pre-configured
Input
Output - Current Signal
Output - Voltage Signal
Supply
Operating Temperature Range
Approvals
535215
Price Each
Order Code
1+
170-6206●
MINI MCR-SL-PT100-UI-NC
This 3-way isolated transducer has a DIP switch configuration option to set the input signals, progressively, from 0 - 0.2A to 0 - 11A as well as standard 1A and 5A.
With a measuring range of 0 - 9.5A to 0 - 55A the unit is ideal for measuring higher motor
currents. AC, DC and distorted currents can equally well be measured.
170-6201●
Thermocouples Type J or K (IEC 584-1)
0(4) to 20 mA, 20 to 0(4) mA
0 to 10V, 10 to 0V, 0 to 5V, 1 to 5V
24V dc @ 25 mA
-20°C to 65°C
ATEX, CE, GL, UL Recognised
H = 93.1, W = 6.2, D = 102.5mm
H = 99, W = 22.5, D = 114.5mm
MCR-S10-50-UI-DCI-NC
1+
MINI MCR-SL-TC-UI-NC
Price Each
Input and Output Currents
40
Price Each
1+
Process Control, Timers & Counters
The 3-way standard signal isolator/amplifier can process
input signals 0-20 mA, 4-20 mA and 0-10V.
The 3-way isolation between signal input, output and supply is set up as "safe isolation" with a test voltage of 4 kV.
H = 99, W = 12.5, D = 114.5mm The transmission cut-off frequency can be set, depending
on application, as either 10 kHz or as a ≤10 Hz filter.
The output has any of of 3 standard signals available. Adjustment after configuration is not
necessary as each transmission variant is calibrated and stored in the device.
This standard signal 3-way isolating amplifier is used to
electrically isolate, condition, amplify and normalize standard signals.
Automation
Ì Suitable for Class 1 Division 2, Groups A, B, C and D
Hazardous locations
Ì Also suitable for non-hazardous applications
Ì M3 screw terminals - Solid/flexible wires 0.2 - 2.5mm
Ì Supply voltage 19.2V dc to 30V dc
Ì CE Approved, UL Recognised
Wide Supply Voltage Range
Mftrs. List No.
1+
1+
Isolation Amplifier - Configurable
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
DIN rail mounting
Adjustable voltage ranges
True rms value measurement
Zero/ Span adjustment ±20%
3-way electrical isolation
Safe isolation according to EN 50178
Supply voltage 18.5 to 30.2V dc
CE Approved, UL Recognised
PT100: 2, 3 or 4 Wire
0(4) to 20 mA, 20 mA to 0(4) mA
0 - 10V, 10 - 0V, 0 - 5V, 1 - 5V
24V dc @ 21 mA
-20°C to 65°C
ATEX, CE, GL, UL Recognised
H = 93.1, W = 6.2, D = 102.5mm
605482
INTELLIGENT ONLINE BUYING
SYSTEM PROVIDING
Complete cost control, reduced
administration time, visibility of your
spend, flexibility and personalised to
your company’s needs.
farnell.com/ibuy
Price Each
Mftrs. List No.
Order Code
MINI MCR-SL-PT100-UI-NC
181-5287●
1+
+
+
IMPROVED BACK ORDER DELIVERY
Receive email updates with the exact status, due
date and despatch information of all your back
order items farnell.com
2935
2936
farnell.com
Analogue Signal Conditioners - continued
element14.com
Signal Converter / Supply Isolator
ACT20M-CI
3-way Isolating Amplifier
Standard Analog Input and Output Signals
Ì Externally supplied ACT20M-CI-CO signal converters/supply isolators can transmit, isolate and convert normalised DC current signals
Ì Input and output circuits are completely electrically isolated, as is
the power supply.
Ì Input signal is converted into a DC current/voltage value
Ì 24 VDC supply voltage can be cross-connected on the module
side via the CH20M BUS profile
Ì International approvals (such as ATEX Zone 2, UL C1D2 and FM
Div2) permit use in explosion-risk zones
Ì DIN Rail mount
Ì Suitable for Class 1 Division 2, Groups A, B, C and D
Hazardous locations
Ì Also suitable for non-hazardous applications
Ì M3 screw terminals - Solid/flexible wires 0.2 - 2.5mm
Ì Supply voltage 19.2V dc to 30V dc
Ì CE Approved, UL Recognised
The 3-way Isolating Amplifier is used to electrically isolate, condition and amplify standard normalized analog
signals.
H = 112.5, W = 6.1, D = 114.3mm
H = 93.1, W = 6.2, D = 102.5mm
660181
Price Each
535223
Price Each
Mftrs. List No.
Order Code
MINI MCR-SL-U-U
170-6208●
1+
Order Code
1175980000
1175990000
207-0743●
207-0746●
Signal Converter / Supply Isolator
Configurable
ACT20M-AI
Automation
Ì DIN Rail mount
Ì Suitable for Class 1 Division 2, Groups A, B, C and D
Hazardous locations
Ì Also suitable for non-hazardous applications
Ì M3 screw terminals - Solid/flexible wires 0.2 - 2.5mm
Ì Supply voltage 19.2V dc to 30V dc
Ì CE Approved, UL Recognised
The 3-way Isolator is a configurable amplifier used to electrically isolate, condition, amplify and filter analog signals.
DIP switches are accessible on the side of the unit and are
used to configure the input and output signal ranges.
H = 93.1, W = 6.2, D = 102.5mm
535222
Mftrs. List No.
Order Code
MINI MCR-SL-UI-UI-NC
170-6207●
1+
Signal Conditioner - PT100 RTD
1+
Process Control, Timers & Counters
H = 97.8, W = 6.1, D = 88mm
5+
10+
Ì ACT20M AI-AO universal U/I- DC- converter/supply isolator and ACT20M-AI-2AO signal multiplier
Ì external power supply for transmitting and isolating analogue DC
current and voltage signals.
Ì The input and output parameters can be configured as required
using the DIP switches
Ì The input/output channel(s) and power supply have 2.5 kV of
electrical isolation
Ì The universal ACT20M-AI-AO-S supply isolator can feed power
directly from the input loop signal to passive sensors
Ì The ACT20M-AI-2AO-S with 4-way isolation is designed as a
signal splitter
Ì The input signal is doubled on the output side
Ì It can be transmitted simultaneously to a controller and an external display
H = 112.5, W = 6.1, Ì International approvals (cULus, ATEX Zone2, FM Div2, GL, DNV).
Ì The power supply can be easily and quickly installed using the
D = 114.3mm
CH20M DIN rail bus. The power can be supplied using any
ACT20M module (up to 20 devices) or a separate ACT20 supply
module (up to 200 devices)
660183
MAS PT100 0 to 100°C
Ì The MAS/MAZ PT100 signal isolating
converters are built into a compact 6.1
mm MICROSERIES housing
Ì 2/3-wire PT100 sensors can be connected on the input side
Ì Calibrated DC current/voltage signals are available on
the output and can be selected using DIP switches
Ì The signal isolating converters are designed with a
two-way isolation of 0.5 kV between the input and
output
Ì The 24 VDC power is supplied over the output circuit
Ì International approvals (such as ATEX Zone 2 and cULusEX C1D2) allow user to use this signal isolating
converter in explosion-risk zones
Price Each
Number of Outputs
Mftrs. List No.
Order Code
Standard Version
1
1176010000
207-0745●
ATEX Versions
1
2
1176000000
1176020000
207-0744●
207-0747●
Mftrs. List No.
Order Code
207-0738●
1+
5+
Signal Conditioner - Thermocouple
J & K Themocouples
660167
Price Each
Thermocouple Type
Mftrs. List No.
Order Code
J 0 to 700°C
K 0 to 1000°C
8615210000
8594830000
207-0739●
207-0740●
1+
5+
10+
10+
Ì ACT20X isolating switch amplifiers are specially
designed for recording NAMUR sensor signals and
digital switching signals which originate from the Ex zone 0
Ì The rail mounted disconnect-switch amplifiers are optionally
available in one- or two-channel versions. With 11 mm width per
channel, the devices need little space in the electrical cabinet
Ì Relay or transistor outputs are used to transmit the signals to the
save zone
Ì Integrated alarm contacts issue an alert in the event of a malfunction which makes troubleshooting easier and increases the system availability
10+
Ì The MAS/MAZ PT100 signal isolating
converters are built into a compact 6.1
mm MICROSERIES housing
Ì Conventional thermocouples can be connected to the
input side, in accordance with IEC 584 type K or J
Ì Calibrated DC current/voltage signals are available on
the output and can be selected using DIP switches
Ì The signal isolating converters are designed with a
two-way isolation of 0.5 kV between the input and
output
Ì The 24 VDC power is supplied over the output circuit
Ì International approvals (such as ATEX Zone 2 and cULusEX C1D2) allow user to use this signal isolating
converter in explosion-risk zones
5+
ACT20X
660163
8594820000
1+
Isolating Switch Amplifiers
Price Each
H = 97.8, W = 6.1, D = 88mm
2936
Mftrs. List No.
1
2
3-way Isolating Amplifier
Price Each
40
Number of Outputs
H = 113.6 W = 22.5, D = 119.2mm
660188
Price Each
Number of Channels
Mftrs. List No.
NO Relay Output
1
Order Code
8965340000
207-0748●
2
8965370000
207-0751●
NC Relay Output
1
2
8965350000
8965380000
207-0749●
207-0752●
NPN Transistor Output
1
2
8965360000
8965390000
207-0750●
207-0754●
Accessories
USB Interface
8978580000
207-0761●
1+
5+
10+
farnell.com
element14.com
Temperature Transducers
USB Interface for Signal Converters
ACT20X
CBX200 USB
Ì The ACT20X-HTI-SAO / 2HTI-2SAO temperature
transducers record temperatures from PT100 sensors and thermocouples from Ex Zone 0 areas
Ì Current loops from 0(4) to 20 mA can also be connected on the
input side
Ì On the output side, there are active and passive current loops
available for the safe area
Ì Integrated alarm contacts issue an alert in the event of a malfunction; this makes troubleshooting easier and increases the system
availability
Ì The rail-mounted current output isolators are optionally available
in one- or two-channel versions
H = 113.6 W = 22.5, Ì With 11 mm width per channel, the devices need little space in
D = 119.2mm
the electrical cabinet
2937
The CBX 100/CBX 200 USB interfaces for PC-based configuring and
calibrating of the ITXPlus universal signal isolating converters, WAVE
TTA and the ACT20 series. The CBX 100/200 USB interface converters have a status LED to display the transmit/receive mode. The driver software is available for download.
660190
Price Each
Number of Channels
Mftrs. List No.
Order Code
1
2
8965470000
8965480000
207-0758●
207-0759●
1+
5+
Price Each
Accessories
USB Interface
8978580000
660192
10+
Mftrs. List No.
Order Code
8978580000
207-0761●
1+
5+
10+
207-0761●
Isolators - ‘Minicoupler’Range
Universal Measurement & Signal Isolating
Converters
Compact
Ì Universal measurement and signal isolating converters can be configured individually
Ì Temperature signals from PT100 sensors and thermocouples as
well as analogue DC current and voltage signals can be recorded
from the Ex Zone 0
Ì On the output side, optional current/voltage or 20 mA current
loop signals are provided for the safe zone
Ì The ACT20X-HUI-SAO-S also has a relay output for configuring
its switching threshold
Ì An integrated alarm contact is available on this device for issuing
an alert in the event of a malfunction which makes troubleshooting easier and also increases system availability
H = 113.6 W = 22.5,
Ì The power supply of the signal isolating converter is either done
D = 119.2mm
using the integrated power supply
Ì The rail mountable devices are designed with one channel and
available in 22.5mm width
Number of Channels
Mftrs. List No.
Order Code
1
8965490000
207-0760●
Accessories
USB Interface
8978580000
207-0761●
1+
5+
10+
± 0.05%
0.1%
1ms (typ.)
1kVdc
Supply voltage range
Operating temperature
Din Rail
20V DC to 28V DC
0°C to 55°C
TS232/TS35
H=89, W=10, D=68
767-270
I to I
4-20mA
50Ω
50mA
4-20mA
Type
Input
Input resistance (typ.)
Maximum over-range
Output
Mftrs. List Nos:
767-281
I to V
4-20mA
50Ω
30mA
0-10V
8594810000=767-270
980681=767-281
40
767-300
V to V
0-10V
500kΩ
15V
0-10V
980683=767-300
FOR SUITABLE POWER SUPPLIES SEE ORDER CODES 767-311 & 767-323
204742
Price Each
Type
Signal Converter - Temperature and Voltage
ACT20M-UI-AO-S
Ì Universal signal isolating converter
Ì For recording, isolating and converting analogue
current/voltage signals and 2/3/4-wire PT100 or TC temperature
sensors
Ì The 3-way electrical isolation of 2.5 kV and an accuracy of up to
0.05% both help to ensure a high degree of process reliability
Ì International approvals (cULus, ATEX Zone2, FM Div2, GL, DNV)
.&nbsp;
Ì External 24VDC power supply is simply snapped onto the
CH20M DIN rail bus for fast and easy installation
Ì The power can be supplied using any ACT20M module (for up to
20 devices) or a separate ACT20 supply module (for up to 200
devices)
Ì The ACT20M-UI-AO signal isolating converter can be configured
with FDT/DTM software
H = 112.5, W = 6.1,
D = 114.3mm
Ì The CBX200 USB interface is used to connect to the PC
Order Code
4-20mA/4-20mA Isolator
4-20mA/0-10V Isolator
0-10V/0-10V Isolator
1+
5+
10+
767-270
767-281
767-300
Process Signal Isolator
This loop powered analogue signal isolator is suitable for most applications,
regardless of whether the loop power is available at the input or output side
of the isolator.
Ì High accuracy at 0.05%
Ì High packing density
Ì Small, compact fitting
Ì Input and output power version
Ì 5 Years manufacturer’s warranty
Ì Made in the EEC
Process Control, Timers & Counters
660191
Price Each
Linearity
Accuracy
Response time
Isolation
Automation
Ì Din Rail mounting, offer cost effective solution to
isolation & signal conversion
Ì 1kV 3 port isolation - input, output to power
Ì Employ surface mount technology for reliability
Ì Ultra compact, 10mm wide
ACT20X-HUI-SAO-S
660169
Price Each
Mftrs. List No.
Order Code
1176030000
207-0742●
1+
5+
10+
Isolation
Accuracy
Stability
Ambient Temperature
Time Constant
Cable Size
Material
Flammability
Mounting
Dimensions
Input
4-20 mA
Output
4-20 mA
1000VAC RMS (Flash tested to 3kV)
0.05% (including hysteresis and linearity)
100 ppm/°C
0 to 70°C;
10 to 95% TH Non-condensing
0.1Sec (to 63% of final value)
4mm2 solid / 2.5mm2 stranded
Polyamide (Grey)
To UL94-V 0, VDE0304 Part 3 Level IIIA
Top hat rail to DIN EN50022-35
12.5 x 60 x 67.5mm
Power
Mftrs.
Requirements
List No.
Input & Output
SEM1020
Order Code
489-4881
381847
Price Each
The first online technical portal for design engineers
Log on, research, refine and design
Mftrs. List No.
SEM1020
Order Code
1+
5+
10+
25+
489-4881
2937
2938
farnell.com
Analogue Signal Conditioners - continued
Limit Value Switch
MINI MCR-SL-UI-REL
Powered Isolating Convertor
The DIP switches located on the side of the housing
have the following functions:
Ì Configuration of the switching hysteresis
Ì Configuration of the operating and closed circuit
current behavior
Ì Setting of relay pickup times
Ì Setting of dropout delay
This powered isolating convertor accepts
most common high level process signals
(current and voltage), isolates them electrically and physically, and converts them to have
voltage and current outputs simultaneously
from a single input.
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Input
Current
Voltage
Protection
Loop supply
Output
Current1
Voltage1
Automation
40
High accuracy at 0.05%
Powers both loops
Drives current into 1KΩ
3 port galvanic isolation
DIN rail or surface mounting
Selectable input and output
5 Years manufacturer’s warranty
H = 93.1, W = 6.2, D = 102.5mm
This 6.2 mm wide configurable 3-way threshold value switch is used to control and monitor analogue standard signals. On the input side, the analogue standards signals 0 to 20
mA or 0 to 10 V per DIP switch can be set. On the output side, a relay with SPDT contact
is available. The switching thresholds are set via potentiometer.
The relay status is indicated by a yellow LED on the front of the housing. Power (19.2 V dc
to 30 V dc) can be supplied through connection terminal blocks on the modules or in conjunction with the DIN rail connector.
4-20, 0-20mA Active or passive (40mA max)
0-100mV, 0-1, 0-5, 0-10V or
20-100mV, 0.2-1, 1-5, 2-10V (20V max)
Internal switches
Voltage: >1MΩ
Current: < 50Ω
Reverse connection/over voltage
25V @ 25mA Nominal (available for input transmitter 27V max)
Selection
Impedance
Linearity
Stability
Adjustment4
0(4) to 20 mA, 0 to 10 V
Output
Supply
SPST Relay - 250V ac @ 2A
24V dc @ 14 mA
Mftrs. List No.
Order Code
MINI MCR-SL-UI-REL
181-5288●
Order Code
851-9943
1+
+
+
Ì Accepts process signals, isolates them electrically and
WARRANTY
converts them to any other
YEARS
process signal
Ì Powers both loops
Ì Compact size
Ì CE approved
Ì High accuracy 0.05%
Ì 3 port galvanic isolation
Ì Accepts powered or unpowered input signals
5
381849
Mftrs. List No.
1+
Mains Powered Isolating Converter
Price Each
SEM1100/S2
Operating Temper- -20°C to 65°C
ature Range
Approvals
ATEX, CE, GL, UL Recognised
605494
5+
10+
25+
Process Signal Isolators
Process Control, Timers & Counters
Ì High accuracy - 0.05%
Ì 500V ac Isolation, flash tested @
WARRANTY
1 kV
YEARS
Ì Compact size
Ì Front entry span and zero potentiometers
Ì CE approved
Ì Can be mounted on 35mm top hat DIN rail
Loop Powered Isolator (898-089)
Ì 4 - 20mA input, 4 - 20mA output
Ì 5V loop drop
Isolator (898-107)
Ì 4 - 20mA input, 4 - 20mA outputs (x 2)
Ì 5V loop drop output
Ì Requires 24V dc power supply on output
5
898-089
Isolated
Current
Powered from Input
H=60, W=12.5, D=60
Input
Output(s)
Power Requirements
Dimensions
898-107
Isolated
Current x 2
Outputs require external power
H=75, W=12.5, D=60
204747
Mftrs.
Type
Loop Powered Isolator
Isolating Signal Splitter
Price Each
List No.
Order Code
SEM1000
SEM1200
898-089
898-107
1+
5+
10+
Ì Small size/high packing density, 21mm wide
WARRANTY
Ì Relays rated at 2A @ 250V ac
YEARS
Ì LED trip indicator
Ì Can be mounted on 35mm top
hat DIN rail
Single Trip Amplifier - Loop Powered
Ì 4 - 20mA input, single 2A @ 250V ac relay output
Ì 5V loop drop
Dual Trip Amplifier - Loop Powered
Ì 4 - 20mA input, dual 2A @ 250V ac relay outputs
Ì 5V loop drop
5
H=60, W=21, D=60
204746
Mftrs.
Type
List No.
Single Trip Amplifier
Dual Trip Amplifier
SEM1401
SEM1402
Price Each
Order Code
898-119
898-120
1+
5+
10+
H=82, W=22, D=100
Input
Output
Loop supply
Supply
Isolation (Input/Output)
Current / Voltage
Current / Voltage
25V @ 25mA
90-253V ac 50/60Hz
500VDC(Flash tested @ 3kV)
204763
Price Each
Mftrs. List No.
Order Code
SEM1100-S1
930-751
1+
5+
10+
25+
Isolation Units - ATEX
DIN Rail Mounting
Compact modular design
DIN Rail mounting
Full input / output / power supply isolation
Broken line and earth fault protection
Simple installation and maintenance using plug-in connectors
Ì No high integrity earth needed
Ì
Ì
Ì
Ì
Ì
25+
Loop Powered Trip Amplifiers
2938
Input
Price Each
4-20, 0-20mA Active or Passive
0-1, 0-5, 0-10 Volts
0.2-1, 1-5, 2-10 Volts
Internal switches
Current 0 to 1KΩ
Voltage Max current 5 mA
0.05% FRO
200 ppm/°C
Zero span potentiometer
plus internal switches
Selection
Load
element14.com
25+
The MTL Series of isolating Intrinsic Safe (IS) interface units offer a compact and easy to
use means for communicating safely with process measurement, indicating, actuating and
local control equipment in hazardous areas. The range of models handle analogue and binary signals in both directions, amplifying or otherwise conditioning them as required and
at the same time providing certified explosion protection for equipment and wiring in all
zones and all explosive atmospheres.
MTL5501-SR - Located in the hazardous area can control an isolated fail-safe electronic
output. Also provides line fault detection alarm contacts.
MTL5511 - Enables a safe area load to be controlled by a switch or proximity detector located in a hazardous area. Also provides a line fault detect facility.
MTL5513 - Enables two solid-state outputs in the safe area to be controlled by two switches or proximity detectors located in the hazardous area. Independent output phase reversal
and line fault detection are available.
MTL5516C - Enables two safe area loads to be controlled by a switch or proximity detector
located in a hazardous area. Line fault detect facility and phase reversal of each channel
are available.
MTL5018AC - Enables two safe area loads to be controlled by two switches or proximity
detectors located in a hazardous area. Independent phase reversal control provided.
MTL5521 - Loop powered module which enables a device located in the hazardous area to
be controlled from the safe area. Can drive a certified intrinsically safe low power load as
well as non-energy storing simple device such as an LED.
MTL5541 - Provide fully floating dc supplies for energising conventional 2-wire or 3-wire
4/20mA or "smart" transmitters located in a hazardous area and repeats the current in other circuits to drive safe area loads. For "smart" 2-wire transmitters, bi-directional communications signals can be superimposed on the 4/20mA signal.
MPA5500 - Enables any MTL5500 Series module that is normally powered from a nominal
farnell.com
24V DC supply (i.e. those that are not looppowered) to be powered from a high-voltage AC
supply. It plugs into the power socket (terminals 13 and 14) of an MTL5500 module and
clips securely onto the module housing. The 25V DC power output from the adaptor is sufficient to supply a single module and can be connected to any normal AC power source.
542093
Price Each
Type
Mftrs. List No.
Digital Input Modules
1 Ch. Failsafe Switch/Proximity Detector Interface
Order Code
MTL5501-SR
174-9533
1 Ch. Switch/Proximity Detector Interface
2 Ch. Switch/Proximity Detector Interface
2 Ch. Switch/Proximity Detector Interface
2 Ch. Switch/Detector Interface
MTL5511
MTL5513
MTL5516C
MTL5018AC
174-9524
174-9525
174-9526
174-9534
MTL5521
174-9527
1+
Mode of operation
Operating temperature
213398
Type
Single Channel
Dual channel
List No.
Order Code
KFD2-SR2-EX-1.W
KFD2-SR2-EX-2.W
730-701
730-713
MTL5541
174-9529
MPA5500
186-2615●
Ì
Ì
Ì
Ì
Ì
DC Standard Zener Barrier
Zener
Ì
Ì
Ì
Ì
1+
5+
10+
25+
KFD2-CD-EX1.32
Accessories
AC Power Adaptor
Price Each
Analogue Output Barrier
Anologue Input Modules - Repeater Power Supply Units
1 Ch. Repeater Power Supply - 2 or 3 Wire Tx
2939
24Vdc ±15%
23ma (single channel), 50ma (dual channel) with energised relay(s)
Open circuit 8Vdc, short circuit 8mA
Single channel - 1 x changeover contacts
2A @ 250Vac, cos ø>0.7, 2A @ 40Vdc (res)
10Hz
Green - power on
Yellow - relay status
Red - sensor condition (lead breakage, short circuit monitoring)
Selected by slide switch(es) on front plate
-20°C to +60
Mftrs.
Digital Output Modules
Solenoid/Alarm Driver - Loop-powered
Supply Voltage
Current consumption (approx)
Intrinsic safe circuit (nom.)
Relay output
Contact rating
Switching speed (max)
LED indication
element14.com
This barrier is used to drive 4-20mA signals from a safe
area into a hazardous area. Typically to drive I/P converters or as an interface to a hazardous area display.
The input and output are isolated from each other and
both are isolated from the power supply
Intrinsically safe EEx ia IIC
Positive polarity
Single channel
DIN rail mounting
28V, 300Ω
28V
301Ω
93 mA
EEx ia IIC
Ex93C2412
Power supply
Safety parameters
Voltage V o
Current I o
Power P o
BASEEFA No.
Calibrated accuracy
Temperature drift
EMC tested
Weight
Ambient temperature
Automation
Commonly used zener barrier which can transmit
both analogue and digital signals bi-directionally
Zener Barrier
Nominal data
Uz
Rmin.
Ik
BASEEFA certified
Certificate no.
Intrinsically safe EEx ia IIC
DIN rail mounting
Accuracy 0.1%
Power supply 20V...35V DC
Single channel
20 to 35V dc
28V 300 Ohms
28V
95mA
660mW
EX-88B2373
≤±0.1% inclusive of non-linearity and hysterisis at 20°C
≤±0.01%
per EN 50 081-2/EN 50 082-2, NAMUR NE21
100g
-20°C to 60°C
214197
40
Price Each
213395
Price Each
Order Code
Z728
710-4157
1+
5+
10+
KFD2-CD-EX1.32.1
Order Code
1+
5+
10+
25+
721-9738
25+
Analogue Signal Converters
CC-E Range
3 Way Isolating Amplifier
MINI MCR-SL-UI-UI-NC
3-way isolating amplifier for the electrical isolation of
analogue signals, I/O can be configured via DIP
switches, with screw connection.
Input - Signal Current
Input - Signal Voltage
Output
Supply
Operating Temperature Range
Approvals
0(4) to 20 mA
0 - 10V, 0 - 5V, 1 - 5V, 2 -10V
0(4)...20 mA; 0...10 V; 0(1)...5 V
24V dc @ 19 mA
-20°C - 65°C
ATEX, CE, GL, UL Recognised
H = 93.1, W = 6.2, D = 102.5mm
605479
Price Each
Mftrs. List No.
Order Code
MINI MCR-SL-UI-UI-NC
170-6207●
1+
+
+
Isolation Amplifiers
Ì Provide galvanic isolation in transferring signals
from a hazardous area
Ì Inputs suitable for DIN19234/NAMUR proximity
sensors
Ì Inputs also suitable for appropriately wired mechanical contacts
Ì Inputs, relay outputs and 240Vdc supply are galvanically isolated from each other
Ì Approved to category EEx ia IIC T4
Ì Certified under PTB Certificate of Conformity No.
Ex94.C.2086 Copy of PTB certificate available on
request
Intrinsically safe barriers are designed to transfer digital signals away from the hazardous
area. Available as a single channel or dual channel unit. The Makrolon modular housing is
rated to UL94V-O, and is for surface or 35mm DIN rail mounting
These devices allow the required input and output
ranges to be configured by means of directly accessible DIP switches positioned on the side of
the unit. Due to the wide input range of the gain
and offset stages all input
signals between the minimum and the maximum input value can be
universally converted to all common output signals.
They provide signal conversion where available signals cannot be
processed by the controller or actuator because the signals are not in
the correct format.
They filter the signals which, particularly on long lines, that are subjected to interference. They are also designed to provide protection against overvoltage and
ground loops.
Ì Universally configurable devices and single-function devices
Ì Adjustment and operating elements on the front side
Ì Safe operation by electrical 3-way isolation
Ì Unambiguous and clear connecting terminal markings
Ì Conversion, measurement and separation of standard signals (0-5 V, 0-10 V, 0-20 mA,
4-20 mA)
Ì temperature signals of RTD sensors (PT 100)
Ì thermocouple signals (types J and K)
Ì current measurement signals (0-5 A, 0-20 A AC/DC)
Ì single-function devices no adjustment or balancing necessary.
Ì universal devices the required input and output ranges can be configured by means DIP
switches
Ì Gain adjustment of ± 5 % by means of an adjustment potentiometer on the front-side
Ì Offset adjustment of ±5 % by means of adjustment potentiometers on the front-side
Ì UL Recognised
Process Control, Timers & Counters
Mftrs. List No.
Mftrs. List No.
636419
Mftrs.
Channels - Description
List No.
Price Each
Order Code
Loop Powered
1 x Current/Current Isolator 1SVR010200R1600
189-5961●
2 x Current/Current Isolator 1SVR010201R0300
189-5962●
24V dc Supply Voltage
1 x Universal Signal
1 x Universal Temperature
1 x Universal Temperature
1 x Single Function Signal
1 x Single Function Signal
1 x Single Function Signal
189-5963●
189-5964●
189-5966●
189-5970●
189-5971●
189-5972●
1SVR011700R0000
1SVR011701R2500
1SVR011702R2600
1SVR011710R2100
1SVR011711R1600
1SVR011712R1700
1+
5+
10+
2939
2940
farnell.com
Analogue Signal Conditioners - continued
Analogue Signal Converters - continued
CC-E Range - continued
Mftrs.
Price Each
Channels - Description
List No.
Order Code
24V dc Supply Voltage
1 x Single Function Signal
1SVR011713R1000
189-5973●
1 x Single Function Signal
1 x Single Function Signal
1 x Single Function Signal
1 x Single Function Signal
1SVR011714R1100
1SVR011716R1300
1SVR011717R1400
1SVR011718R2500
189-5974●
189-5975●
189-5976●
189-5978●
1SVR011705R2100
1SVR011706R2200
1SVR011707R2300
189-5967●
189-5968●
189-5969●
1+
5+
10+
110 - 240V ac Supply
1 x Universal Signal
1 x Universal Temperature
1 x Universal Temperature
ON-delay
OFF-delay
Flicker (2 types)
Differential (2 types)
One-shot
One-cycle
Time Range
0.1s - 500h (16 time ranges)
Input
Start, Stop, Reset, Lock
Input Signal
Potential-free contact, start in case of power-on
Output
Relay 2c, 5A 250V ac
Life
2.0 x 107 operation (Mech), 1.0 x 105 operation (Elec.)
Operating Voltage
24VAC/dc, 24VAC or 100-240V ac
(Range: 85-110%)
Protective Construction
IP50
Dimensions
48x48x62mm
Front Mounting
Screw terminal or 11pin type + socket AT78051J
+ mounting frame AT8DA4J
DIN-Rail Mounting
11 Pin type + Socket ATC180041J
Mounting frame is only included at screw terminal type.
475756
Analogue Signal Converters
Automation
40
8 Operation Types (Multi-function)
Price Each
CC-U Range
These devices allow the required input and output ranges to be
configured by means of directly accessible DIP switches positioned
on the side of the unit. Due to the wide input range of the gain and
offset stages all input
signals between the minimum and the maximum input value can be
universally converted to all common output signals.
They provide signal conversion where available signals cannot be
processed by the controller or actuator because the signals are not
in the correct format.
They filter the signals which, particularly on long lines, that are subjected to interference. They are also designed to provide protection
against overvoltage and ground loops.
Ì
Ì
Ì
Ì
Ì
Ì
Ì
element14.com
Voltage
Terminal
Mftrs. List No.
24VDC24VAC/
dc
24VDC24VAC/
dc
100 - 240VAC
100 - 240VAC
11 Pin Type
PM4HA-H-24V
Process Control, Timers & Counters
Input
List No.
Output
24V to 48V dc Supply Voltage
Signal - DIP switches
1SVR040000R1700
RTD Sensors - DIP switches
Thermocouples - DIP switches
RMS Values (0-5A) - DIP
switches
RMS Values (0-600V) - DIP
switches
Analogue Signal - 2 x Relay
RTD Sensors - Relay
Thermocouples - Relay
110 - 240V ac Supply
Signal - DIP switches
RTD Sensors - DIP switches
Thermocouples - DIP switches
RMS Values (0-5A) - DIP
switches
RMS Values (0-600V) - DIP
switches
Analogue Signal - 2 x Relay
RTD Sensors - Relay
Thermocouples - Relay
1SVR040002R0500
1SVR040004R0700
1SVR040006R0100
1+
5+
Accessories
Rear Terminal Socket
DIN-Rail Socket
Mounting Frame
AT78051
ACT180041
AT8-DA4
Nominal Supply Voltage
24 - 230VAC/dc
Output
Rated Current/Max Peak Current
8/15A
Rated Voltage/Max Switching Voltage 250/250 V ac
Rated Load AC1
2000 VA
Rated Load AC15
400 VA
Time Scale Selector
0.5, 1, 5, 10
Unit of Time Selector
Sec, Min, Hrs, 10 Hrs
Repeatability
±1%
Recovery Time
300 ms
Minimum Control Impulse
50 ms
Setting Accuracy Full Range
±3%
Electrical Life at Rated Load AC1
100,000
Cycles
Ambient Temperature
-10 to 55°C
Protection Category
IP40
189-5979●
189-5985●
137-3681●
137-3683●
137-3684●
Multi-Function 11 Pin Plug In or
Panel Mounting Timer
10+
189-5981●
189-5983●
10+
137-3676●
11 Pin Type
PM4HA-H-AC240V 137-3677●
Screw Terminal PM4HA-HAC240VS 137-3678●
Price Each
Order Code
5+
137-3674●
636639
Mftrs.
1+
Screw Terminal PM4HA-H-24VS
8 different standard signal outputs on one device
Input and output side universally configurable
Also available with 2 threshold relay outputs
Adjustment and operating elements on the front side
Safe operation by electrical 3-way isolation
Plug-in connecting terminals, unambiguously and clearly marked
UL Recognised
Channels - Description
Order Code
Ì
Ì
Ì
Ì
24 to 230V ac/dc operation
7 timing functions
16 time ranges 0.05 sec to 100 hrs
Pause, Start and Reset inputs
Ì LED status indicators
Ì 48x48mm front panel
Ì Panel mount fixings included
475900
1SVR040008R1300
1SVR040010R0000
1SVR040012R2600
1SVR040014R2000
1SVR040001R0400
1SVR040003R0600
1SVR040005R0000
1SVR040007R0200
189-5987●
189-5991●
189-5993●
189-5995●
189-5980●
189-5982●
189-5984●
Price Each
Supply Voltage
Mftrs. List No.
Order Code
24 - 230VAC/dc
88.02.0.230.0002
134-4239●
5+
10+
Multi-Function 11 Pin Plug In or
Panel Mounting Timer
24 to 230V ac/dc operation
6 timing functions
16 time ranges 0.05 sec to 100 hrs
2 timed or 1 timed + 1 instantaneous
contact
Ì LED status indicators
Ì 48x48mm front panel
Ì Panel mount fixings included
Ì
Ì
Ì
Ì
189-5986●
1SVR040009R1400
1SVR040011R2500
1SVR040013R2700
1SVR040015R2100
1+
189-5988●
189-5992●
189-5994●
189-5996●
Electronic Timers
Multifunction Timer DIN1/16
PM4H
Ì Robust and big set dial - set dial can easily be used
with gloves
Ì Operation can be checked by two LEDs (power and
operation)
Ì Output: 2 relays 5A 250V ac
Ì Standards: CE, UL, CSA, Lloyd
Ì Installation: front and DIN-rail mounting
Nominal Supply Voltage
24 - 230VAC/dc Unit of Time Selector
Sec, Min, Hrs,
10 Hrs
Repeatability
±1%
Recovery Time
200 ms
Setting Accuracy Full Range
±3%
Electrical Life at Rated Load AC1 100,000 Cycles
Ambient Temperature
-10 to 55°C
Protection Category
IP40
Output
Rated Current/Max Peak Current
Rated Voltage/Max Switching Voltage
Rated Load AC1
Rated Load AC15
Time Scale Selector
5/10A
250/400 V ac
1250 VA
250 VA
0.5, 1, 5, 10
475905
Supply
Voltage
24 - 230VAC/dc
2940
Mftrs.
Price Each
List No.
Order Code
88.12.0.230.0002
134-4240●
1+
5+
10+
farnell.com
Miniature 4-Pole Changeover - H3Y4
ASTRO Series - Three Phase
Order Codes
Time Range
100-120V ac 200-230V ac
0.1 - 1s
—
0.2 to 5secs
—
104-046
0.5 to 10s
104-042
1 to 30s
—
2 to 60s
104-044
104-049
0.1 to 3m
—
—
0.2-5m
—
—
0.5min to 10min
—
104-664
H=56.6, W=20.7, D=27.2 1-30m
—
2-60m
—
104-666
Operating mode
Time ranges
Repeat accuracy
Reset time
Delay on energisation
See ordering info
±2% max.
0.1s max.
Output time contacts
Contact rating
Operating voltage
Operating voltage range
12V dc
—
104-026
104-028
—
—
—
—
24V dc
104-674
104-036
104-037
104-038
104-039
104-040
104-675
—
104-677
632383
Price Each
Order Code
24/100-120/200
- 230V ac
All Order Codes
12/24V dc
All Order Codes
Sockets
Chassis
Surface/DIN rail
Ì Dynamic and accurate control based on astronomical mathematics
Ì Yearly programming with season
mode, DST, Offset, Off hours enabled
Ì Protection against under voltage and
over voltage
Ì Active Phase selection & Auto load changeover feature
H = 90.5, W = 72,
Ì Three independent channel outputs
D = 65mm
Ì 110 - 240V ac supply, 3 Phase 4 Wire (P-N)
Ì 3 NO (SPST) outputs. 8A @ 240V ac, 5A @ 30V dc (resistive)
Ì Manual override facility
Ì Includes Data-stick and Software
—
4PCO
3A @ 250V ac
See ordering information
80-110%
223116
Voltage
Timers
1+
5+
10+
1+
20+
100+
25+
50+
Mftrs.
Price Each
Description
List No.
Order Code
Astro Timer
T3DDT0
189-5463●
1+
3+
5+
10+
Accessories
GSM Module
19D20B00 189-5464●
Surge Suppressor 19D2000C 189-5465●
Comms. cable
19A1000B 189-5466●
Delay On Timer
Type M1EDO
427-342
134-0953●
424-651
103-924
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Time Switch Modules
12 Series
Automation
Retaining Clips
Chassis/PCB
Surface/DIN rail
17.5mm Width DIN Rail housing
Delay On Energisation
Supply indication
Output relay - 8A SPCO contact
Relay indication
Dual voltage
UL and CUL Approved
Conforms to CSA, IEC and CE
618341
Timer
Range
12.71
H = 90, W = 17.8,
D = 63mm
627512
Output
Mftrs.
Type
List No.
Price Each
Order Code
Mechanical - 230V ac Supply
1CO - 16A @ 250V ac - Daily
12.31.8.230.0000 188-9078●
1CO - 16A @ 250V ac - Weekly
12.31.8.230.0007 188-9079●
Digital - 24V ac/dc Supply
1CO - 16A @ 250V ac - Weekly
12.71.0.024.0000 188-9080●
Digital - 230V ac Supply
1CO - 16A @ 250V ac - Weekly
1CO - 16A @ 250V ac - Weekly
1CO - 16A @ 250V ac - Weekly (P)
2CO - 16A @ 250V ac - Weekly
2CO - 16A @ 250V ac - Weekly (P)
12.71.8.230.0000 188-9081●
12.91.8.230.0000 188-9082●
12.91.8.230.0090 188-9083●
12.92.8.230.0000 188-9085●
12.92.8.230.0090 188-9086●
Accessories
Programming Kit - 12.91(P) and 12.92(P)
012.90
1+
10+
2s to 60s
0.5s to
10min
2min to
60min
Mftrs.
Mono-function - 230V ac Supply
1NO - 16A @ 230V
14.91.8.230.0000
Price Each
188-9088●
185-3741●
185-3745●
185-3744●
185-3743●
185-3742●
17.5mm Width DIN Rail housing
Delay Off - Switch initiated
Supply indication
Output relay - 8A SPCO contact
Relay indication
Dual voltage
UL and CUL Approved
Conforms to CSA, IEC and CE
618343
Timer
Range
Price Each
Mftrs. List No.
Order Code
1+
5+
10+
24V ac/dc, 230V ac - Supply voltage
0.5s to 10s M1ESW 24VAC/DC//230VAC 10SECS 185-3749●
627514
Order Code
10+
M1EDO 24VAC/DC//230VAC 60SECS
185-3748●
M1EDO 24VAC/DC//230VAC .5-10MINS
185-3747●
M1EDO 24VAC/DC//230VAC 2-60MINS
185-3746●
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
188-9087●
Time setting from 30s to 20min
Zerocrossing load switching
Can be used with illuminated push-buttons
DIN Rail mount
3 terminals on the same side
Controls can be operated by blade or cross head screw drivers
35mm DIN Rail mounting
List No.
5+
Delay Off Timer
H = 88.8, W = 17.5, D = 60.8mm
Type
1+
Type M1ESW
Staircase Timer
Output
Order Code
24V ac/dc, 110V ac - Supply voltage
0.5s to 10s M1EDO 24VAC/DC//110VAC .5-10SECS
2s to 60s M1EDO 24VAC/DC//110VAC 2-60SECS
0.5s to
M1EDO 24VAC/DC//110VAC .5-10MINS
10min
2min to
M1EDO 24VAC/DC//110VAC 2-60MINS
60min
14 Series
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Mftrs. List No.
24V ac/dc, 230V ac - Supply voltage
0.5s to 10s M1EDO 24VAC/DC//230VAC 10SECS
12.9 Series
H = 90, W = 35.8, D = 63mm
40
Price Each
Process Control, Timers & Counters
12.31 Series
H = 72, W = 72, D = 51.4mm
2941
Astronomical Time Switch
Miniature adjustable timer
Compatible with Omron LY and MY relays
Connection by 14 pin socket
Panel adaptor available for panel mounting
Ì
Ì
Ì
Ì
element14.com
1+
25+
100+
2s to 60s
M1ESW 24VAC/DC//230VAC 60SECS 185-3757●
0.5s to 10min M1ESW 24VAC/DC//230VAC 10MINS 185-3756●
2min to 60min M1ESW 24VAC/DC//230VAC 60MINS 185-3755●
24V ac/dc, 110V ac - Supply voltage
0.5s to 10s M1ESW 24VAC/DC//110VAC 10SECS
2s to 60s
M1ESW 24VAC/DC//110VAC 60SECS
0.5s to 10min M1ESW 24VAC/DC//110VAC 10 MINS
2min to 60min M1ESW 24VAC/DC//110VAC 60MINS
185-3754●
185-3753●
185-3751●
185-3750●
2941
2942
farnell.com
Electronic Timers - continued
Multirange Electronic Timers
Interval Timer
Digital Twin Timer
Type M1EIN
LT4H-W
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
element14.com
Ì Twin timer: two independent timing functions
available simultaneously: TimeON - TimeOFF
Ì Wide time range: 0.01s to 9999h
Ì 2 colour backlight LCD display of elapsed and
set time
Ì Easy time setting by seesaw buttons
Ì Cover also in black (please order timer & cover
ATL58011J)
Ì Power failure memory by EEPROM
Ì Standards, CE, UL, CSA
Ì Installation: front & DIN-Rail mounting
17.5mm Width DIN Rail housing
Interval (Single shot) timer
Supply indication
Output relay - 8A SPCO contact
Relay indication
Dual voltage
UL and CUL Approved
Conforms to CSA, IEC and CE
6 Operation Types (Multi-function)
618344
Timer
Range
Price Each
Mftrs. List No.
Order Code
24V ac/dc, 230V ac - Supply voltage
0.5s to 10s M1EIN 24VAC/DC//230VAC 10SECS
1+
5+
10+
185-3758●
2s to 60s
M1EIN 24VAC/DC//230VAC 2-60SECS 185-3760●
0.5s to 10min M1EIN 24VAC/DC//230VAC .5-10MINS 185-3759●
24V ac/dc, 110V ac - Supply voltage
0.5s to 10min M1EIN 24VAC/DC//110VAC .5-10MINS 185-3761●
0.5s to 10s M1EIN 24VAC/DC//110VAC .5-10SECS 185-3763●
2s to 60s
M1EIN 24VAC/DC//110VAC 2-60SECS 185-3762●
Pulse input & Integrating Input: Delayed on shot
OFF-start flicker
ON-Start flicker
Time Range
0.01s - 9999h (16 time ranges)
Input
Start, Stop, Reset, Lock
Input Signal
Potential-free contact, start in case of power-on
Output
Relay c, 5A 250V ac
Life
2.0 x 107 operation (Mech), 1.0 x 105 operation (Elec.)
Operating Voltage
12/24VDC, 24VAC or 100-240V ac
(Range: 85-110%)
Protective Construction
IP66
Dimensions
48x48x65mm
Front Mounting
Screw terminal o. 11pin type + socket AT78051J
DIN-Rail Mounting
11 Pin type + Socket ATC180041J
Mounting frame, rubber gasket and instruction manual (in six languages) are included.
475643
Automation
Mftrs.
Voltage
True Delay Off Timer
40
Accessories
Rear Terminal Socket
DIN-Rail Socket
Flexible Protective Cover
17.5mm Width DIN Rail housing
True Delay Off (Delay On Release)
Supply indication
Output relay - 8A SPCO contact
Dual voltage
UL and CUL Approved
Conforms to CE
1+
5+
10+
Process Control, Timers & Counters
Ì
Ì
Ì
Ì
Ì
Ì
Ì
618346
Order Code
24V ac/dc, 110V ac - Supply voltage
2s to 60s
M1EDF 24VAC/DC//110VAC 60SECS
185-3766●
0.5s to 10min M1EDF 24VAC/DC//110VAC 10MINS
185-3765●
AT78051
ACT180041
AQM4803
137-3681●
137-3683●
137-3685●
PM5S
Price Each
Mftrs. List No.
Order Code
Multifunction Timer for DIN-Rail
Timer
Range
List No.
12 - 24VDC or 24VAC 11 Pin Type LT4HW-DC24V 137-3668●
12 - 24VDC or 24VAC Screw Terminal LT4HW-DC24VS 137-3669●
100 - 240VAC
11 Pin Type LT4HW-AC240V 137-3670●
100 - 240VAC
Screw Terminal LT4HW-AC240VS 137-3671●
Type M1EDF
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Terminal
Price Each
1+
5+
10+
Free-voltage input 24 - 240V AC/ DC
Built-in screw terminals
Multiple time ranges 1s - 500h
Output: 2 relays 5A 250V AC
Instruction manual in six languages
Standards: CE, UL, CSA
Installation: DIN-rail mounting
Asymmetrical Recycler
Type M1ARM
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
17.5mm Width DIN Rail housing
Asymmetrical Recycling Off/On or On/Off (selectable)
Multi-voltage supply: 24 - 240V AC / DC
Selectable time ranges for ON and OFF periods (up to 60mins)
Separate adjustments for ON and OFF periods
Output relay - SPCO 8A Contact
LED indication of supply and output relay status
Conforms to IEC and CE
6 Operation Types (Multi-function)
ON-delay
OFF-delay
Flicker (2 types)
One-shot
One-cycle
1s - 500h (16 time ranges)
Potential-free contact, start in case of power-on
Relay 2c, 5A 250V ac
2.0 x 107 operation (Mech), 1.0 x 105 operation (Elec.)
24 - 240VAC /dc (range: 85-110%)
IP40
22.5x75x98mm
Time Range
Input Signal
Output
Life
Operating Voltage
Protective Construction
Dimensions
475761
618347
Timer
Range
Mftrs.
Price Each
Mftrs. List No.
Order Code
24 to 240V ac/dc - Supply voltage
2min to 60min M1ARM 24-240VAC/DC 60MINS
1+
5+
185-3767●
10+
Voltage
24 - 240VAC/dc
Terminal
List No.
Price Each
Order Code
1+
5+
10+
Screw terminal PM5S-A-24-240V 137-3679●
ON-delay Timer DIN 1/16
QM4H
INTELLIGENT ONLINE BUYING
SYSTEM PROVIDING
Complete cost control, reduced
administration time, visibility of your
spend, flexibility and personalised to
your company’s needs.
farnell.com/ibuy
2942
Ì Easy and fast set of time and time range with mechanical time switches - also during power off
Ì Digital 7-Segment-display of elapsed time
Ì All settings at the front
Ì Output: 2 relays 5A 250V AC
Ì Selectable contact arrangement: 2x relays delayed or
1x relay delayed and 1x relay instantaneous
Ì Instruction manual in six languages
Ì Standards: CE, UL, CSA
Ì Installation: front and DIN-rail mounting
farnell.com
1 Operation Type (Mono-function)
Time Range
Input
Input Signal
Output
Life
Operating Voltage
ON-delay
0.1s - 9990h (8 time ranges)
Stop, Reset
Potential-free contact, start in case of power-on
Relay 2c, 5A 250V ac
2.0 x 107 operation (Mech), 1.0 x 105 operation (Elec.)
12-48V ac/dc, or 100-240V ac
(Range: 85-110%)
Protective Construction
IP50
Dimensions
48x48x72mm
Front Mounting
Pin type + socket AT78041J
DIN-Rail Mounting
Pin type + Socket ATC180031J
Mounting frame and instruction manual (in six languages) are included
element14.com
2943
Price Each
Description
Mftrs. List No.
Push-in Terminals
ON-delay
CT-ERS.22P
OFF-delay
OFF-delay
OFF-delay
OFF-delay
475763
Order Code
1+
5+
10+
189-6024●
189-6025●
189-6026●
189-6028●
189-6029●
CT-AHS.22P
CT-ARS.11P
CT-ARS.21P
CT-APS.12P
Zelio Time - Timing Relays
Price Each
Voltage
12 - 48VDC
100 - 240VAC
Terminal Mftrs. List No.
Order Code
1+
5+
10+
8 Pin Type QM4HS-U2C-48V 137-3672●
8 Pin Type QM4HS-U2C-240V 137-3673●
Accessories
Rear Terminal Socket
DIN Rail Socket
Flexible Protective Cover
AT78041
ATC180031
AQM4803
137-3680●
137-3682●
137-3685●
Modular Solid State Timer
80 Series
RE11
DIN rail mounted relays (RE8, RE9, RE11) designed for mounting on DIN rails in an enclosure. These relays have one, two or four outputs. Sometimes the second output can be either timed or instantaneous. If the power is switched off during the timing period, the relay
reverts to its initial position.
Application: Opening of automatic doors, alarm, lighting in toilets and car park barriers
Output Current
Operating temperature
Relative humidity
IP degree of protection
Approvals
Electrical durability
H = 88.8, W = 17.5, D = 60.8(OA)mm
538343
Price Each
Nominal Supply
Voltage
Switching Output
240V ac/dc
1A / 240V ac
Mftrs. List No.
Order Code
80.71.0.240.0000
171-8979●
1+
CT-D and CT-S Ranges
Ì
Ì
Ì
Ì
Ì
Tool-free mounting/dismounting DIN Rail mount range of timers
Can be fitted in standard distribution cabinets
Output contact(s) - CT-D Range 250V ac / 24V dc 6A
Output contact(s) - CT-S Range 250V ac / 24V dc 4A
CSA, GL, GOST and CCC Approved. UL Recognised
383590
Price Each
Description
Mftrs. List No.
Order Code
Screw Type Terminals
CT-D Range
Multi Function Timer CT-MFD.12
864-1994
ON-Delay Timer
OFF-Delay Timer
CT-ERD.12
CT-AHD.12
864-2001
864-2010
CT-S Range
Multifunction
Multifunction
Multifunction
Multifunction
Multifunction
Multifunction
ON-delay
ON-delay
OFF-delay
OFF-delay
OFF-delay
OFF-delay
CT-MFS-21S
CT-MBS.22S
CT-MVS.21S
CT-MVS.23S
CT-MXS.2S
CT-WBS.22S
CT-ERS.12S
CT-ERS.22S
CT-AHS.22S
CT-ARS.11S
CT-ARS.21S
CT-APS.12S
189-6004●
189-6005●
189-6006●
189-6007●
189-6008●
189-6009●
189-6010●
189-6011●
189-6012●
189-6013●
189-6014●
189-6016●
Push-in Terminals
Multifunction
Multifunction
Multifunction
Multifunction
Multifunction
Multifunction
ON-delay
CT-MFS.21P
CT-MBS.22P
CT-MVS.21P
CT-MVS.23P
CT-MXS.22P
CT-WBS.22P
CT-ERS.12P
189-6017●
189-6018●
189-6019●
189-6020●
189-6021●
189-6022●
189-6023●
1+
5+
10+
5A
-20°C to +60°C
15 to 85% (3K3) conforming to IEC 60721-3-3
IP20 (terminals)
IP50 (housing)
CSA, GL and UL
> 100000000 cycles
Timing
Supply
Range
Voltage
On delay timing relay
1s to 100h
24 to 240 V AC/DC
1s to 100h
24 V AC/DC to 240 VAC
1s to 100h
24 V AC/DC to 240 VAC
1s to 100h
24 V AC/DC to 240 VAC
1s to 100h
24 V AC/DC to 240 VAC
3s to 300s
24 V AC/DC, 110 to 240 V AC/DC
3s to 300s
24 to 240 V AC/DC
0.3s to 30s
24 V AC/DC, 110 to 240 V AC/DC
20s to 30m
24 V AC/DC, 110 to 240 V AC/DC
0.1s to 10s
24 to 240 V AC/DC
0.3s to 30s
24 to 240 V AC/DC
Off delay timing relay
1s to 100h
24 to 240 V AC/DC
3s to 300s
24 to 240 V AC/DC
0.3s to 30s
24 to 240 V AC/DC
20s to 30m
110 to 240 VAC
0.1s to 10s
24 V AC/DC, 110 to 240 V AC/DC
0.1s to 10s
24 V AC/DC, 110 to 240 V AC/DC
0.1s to 10s
24 to 240 VAC
0.3s to 30s
24 to 240 VAC
10 functions delay timing relay
1s to 100h
12 to 240 V AC/DC
1s to 100h
24 to 240 V AC
1s to 100h
24 VDC, 24 to 240 VAC
8 functions delay timing relay
1s to 10h
24 VDC, 24 to 240 VAC
9 functions delay timing relay
1s to 100h
24 VDC, 24 to 240 VAC
Impulse, one shot timing relay
1s to 100h
24 VDC, 24 to 240 VAC
Industrial, pulse on timing relay
0.1s to 10s
24 V AC/DC, 110 to 240 VAC
Star delta timing relay
0.3s to 30s
24 V AC/DC
0.1s to 10s
24 V AC/DC, 110 to 240 VAC
0.3s to 30s
24 V AC/DC, 110 to 240 VAC
Rated
Current
Mftrs.
List No.
Order Code
0.7 A
8A
8A
8A
8A
8A
5A
8A
8A
0.7 A
0.7 A
RE11LAMW
RE11RAMU
RE11RCMU
RE11RHMU
RE11RLMU
RE8TA21BU
RE8TA21BUTQ
RE8TA31BUTQ
RE8TA41BUTQ
RE9TA11MW
RE9TA31MW
205-6303
205-6307
205-6312
205-6313
205-6314
205-6326
205-6327
205-6328
205-6329
205-6336
205-6337
0.7 A
8A
8A
8A
8A
8A
0.7 A
0.7 A
RE11LCBM
RE8RA21BTQ
RE8RA31BTQ
RE8RA41FUTQ
RE8RB11BUTQ
RE8TA11BUTQ
RE9RA11MW7
RE9RA31MW7
205-6309
205-6321
205-6322
205-6323
205-6324
205-6325
205-6334
205-6335
8A
0.7 A
8A
RE11RMMW
RE11LMBM
RE11RMMU
205-6308
205-6310
205-6316
5A
RE11RMEMU
205-6315
8A
RE11RMXMU
205-6317
8A
RE11RBMU
205-6311
8A
RE8PE11BUTQ
205-6319
8A
8A
8A
RE8YA32BTQ
RE8YG11BUTQ
RE8YG31BUTQ
205-6330
205-6332
205-6333
40
Process Control, Timers & Counters
Electronic Timers
RE8
Automation
Multi-function, multi-voltage solid state output
Six time scales from 0.1s to 24h
High input/output isolation
Multi-voltage output - 24 to 240V ac/dc independent from input voltage
Ì IP20 protection level
Ì CE Marked
Ì
Ì
Ì
Ì
RE9
640486
Mftrs.
Price Each
List No.
Order Code
On delay timing relay
RE11LAMW
RE11RAMU
RE11RCMU
RE11RHMU
RE11RLMU
RE8TA21BU
RE8TA21BUTQ
RE8TA31BUTQ
RE8TA41BUTQ
RE9TA11MW
RE9TA31MW
205-6303●
205-6307●
205-6312●
205-6313●
205-6314●
205-6326●
205-6327●
205-6328●
205-6329●
205-6336●
205-6337●
1+
5+
10+
25+
50+
2943
2944
farnell.com
Multirange Electronic Timers - continued
Multi Function, Multi Voltage Timer
Type M1MFM
Zelio Time - Timing Relays - continued
Mftrs.
element14.com
Price Each
List No.
Order Code
1+
5+
10+
25+
50+
RE8RA21BTQ
RE8RA31BTQ
RE8RA41FUTQ
RE8RB11BUTQ
RE8TA11BUTQ
RE9RA11MW7
RE9RA31MW7
17.5mm Width DIN Rail housing
Delay On Operate, Interval, Symmetrical Recycling Off/On or On/Off
Multi-voltage supply: 24 - 240V ac / dc
Two time ranges available: 0.5secs - 60mins or 5secs to 10hours
DIP Switch facility allows one of 4 ranges to be selected
1 x SPDT relay output 8A
LED indication for relay status
Conforms to UL, CUL, CSA and IEC
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Off delay timing relay
RE11LCBM
205-6309●
205-6321●
205-6322●
205-6323●
205-6324●
205-6325●
205-6334●
205-6335●
618340
Price Each
10 functions delay timing relay
RE11RMMW
RE11LMBM
RE11RMMU
205-6308●
205-6310●
205-6316●
8 functions delay timing relay
RE11RMEMU
Mftrs. List No.
Order Code
M1MFM 60MINS
185-3738●
Ì
Ì
Ì
Ì
Ì
Ì
Ì
205-6317●
Impulse, one shot timing relay
205-6311●
Industrial, pulse on timing relay
RE8PE11BUTQ
10+
38 Series
9 functions delay timing relay
RE11RBMU
5+
Timed Relay Interface Modules
205-6315●
RE11RMXMU
1+
205-6319●
Automation
SPDT Electromechanical output relay or
SPST-NO 2A DC or AC Solid State Relay output
Multi function timer, AI: DI: GI & SW
4 Time scales from 0.1s to 6h
Instant relay ejection
35mm rail (EN 60715) mount
CE, Gost Approved, UL Recognised
Star delta timing relay
RE8YA32BTQ
RE8YG11BUTQ
RE8YG31BUTQ
205-6330●
205-6332●
205-6333●
H = 87.9, W = 6.2, D = 75.6(OA)mm
538341
Price Each
Nominal Supply Voltage
Micron姞 Electronic Timer
Multi-voltage - Multi-function
Ì
Ì
Ì
Ì
Ì
40
Process Control, Timers & Counters
Ì
Ì
H = 89, W = 17.5, Ì
D = 76mm
Ì
Slim 18mm wide enclosure
35mm rail mount
Wide time range (0.1s to 100h)
Highly accurate
Multi-function (10 different functions - Signal
and non-signal)
Multi-voltage (12 - 240V ac/dc)
8A @ 240V ac, 5A @ 24V dc SPDT relay output
Separate indicators for power and relay status
Low power consumption
Switching Output
Functions - Output List No.
6A / 250V ac
38.21.0.012.0060
171-8974●
6A / 250V ac
38.21.0.024.0060
171-8975●
SSR Relay
24V ac/dc
2A / 240V ac
38.21.0.024.8240
171-8978●
1+
3+
5+
Ì Standard multiple time ranges and multiple operating modes
Ì Compatable with Omron G2R relays and
sockets
Ì SPCO or SPNO contact outputs available
Ì Conforms to VDE0435/P2021 and EMC
standards
Ì UL recognised and CSA approved
10+
10 Modes - SPDT 1CMDT0 189-5467●
ELIRO Digital Timer
Multi-voltage - Multi-function
H=47.4, W=12.8, D=28.8
Ì Multi-voltage (24 -240V ac/dc)
Operating modes
Ì Multi-function(8 or 17)
Ì 3 digit LCD for Preset time and Run time
Ì Option to select Up/Down counting
Ì
Ì
Ì
Ì
Time ranges
Voltage
Price Each
Functions - Output List No.
Order Code
8 - SPDT
8 - DPST
17 - SPDT
17 - DPST
189-5458●
189-5459●
189-5460●
189-5462●
V0DDTS
V0DDTD
VODDTS1
V0DDTD1
1+
5+
C : Recycling OFF start
D : Recycling ON start
0.1-1s, 1-10s, 0.1m-1m, 1-10m
0.1-1m, 1-10m, 0.1-1h,1-10h
Price Each
632381
Mftrs.
A : ON delay
B : Interval timing
Short range models
Long range models
223067
Tamper proof with key lock function
All settings accomplished with only two keys
Slim 17.5mm wide enclosure
35mm rail mount
H = 89, W = 17.5,
D = 76mm
10+
25+
Mftrs. List No.
Order Code
Short Range Timer - SPCO
12VDC
H3RN-1 12VDC
734-391
24VDC
H3RN-1 24VDC
734-408
Short Range Timer - DPNO
12VDC
H3RN-2 12VDC
24VDC
H3RN-2 24VDC
734-421
734-433
Long Range Timer - SPCO
12VDC
H3RN-11 12VDC
24VDC
H3RN-11 24VDC
Sockets
SPCO Surface/DIN rail
DPCO Surface/DIN rail
DPCO PCB
1+
5+
10+
1+
20+
100+
734-457
734-469
134-0954●
134-0956●
992-082
TROUBLESHOOTING TIPS
Chat online to one of our
technical engineers at farnell.com
The first online technical portal for design engineers
Log on, research, refine and design
2944
1+
Ultra-Slim, Multifunction - H3RN Series
Price Each
Order Code
Order Code
24V ac/dc
632385
Mftrs.
Mftrs. List No.
Electromechanical Relay
12V ac/dc
50+
farnell.com
Miniature 4 Pole Changeover - H3YN Series
Ì
Ì
Ì
Ì
Ì
Pin compatible with Omron MY relays
Standard multiple operating modes and multiple time ranges
DPDT or 4PDT contact outputs available
Conforms to VDE 0435/P2021
UL recognised and CSA approved
Coil Operating
Mftrs.
Voltage
List No.
2 Pole Change Over
12V ac/dc
85.02.0.012.0000
426-8908
24V ac/dc
85.02.0.024.0000
426-8910
85.04.0.012.0000
85.04.0.024.0000
85.04.0.125.0000
85.04.8.240.0000
426-8829
426-8830
426-8842
426-8854
H=56.6, W=21.5, D=28
C : Recycling OFF start
D : Recycling ON start
0.1-1s, 1-10s, 0.1-1m, 1-10m
0.1-1m, 1-10m, 0.1-1h,1-10h
94.04SMA
426-9081
For 2 & 4 Pole Versions
223079
Mftrs. List No.
Order Code
Short Range Timer - DPCO
24VAC
H3YN-2-24AC
986-800
24VDC
230VAC
986-811
986-835
H3YN-2-24DC
H3YN-2-200/230AC
1+
5+
10+
H3DS, with Smart Locking Function
Ì Unique ability to be able to lock off individual settings from either accidental or malicious change.
Ì Lock can only be unlocked and locked with locking
tool sold separately (377-4181)
Ì Only 17.5mm wide.
Ì 6 units to the family, 2 general-purpose multi-function models, and 4 more dedicated mono function
units.
Price Each
Voltage
Price Each
Order Code
94 Series Sockets (IP20)
A : ON delay
B : Interval timing
Short range models
Long range models
Time ranges
2945
4 Pole Change Over
12V ac/dc
24V ac/dc
125V ac/dc
240V ac/dc
Operating modes
element14.com
1+
5+
10+
25+
Long Range Timer - DPCO
230VAC
H3YN-21-200/230AC
986-872
H=80, W=17.5, D=68
Short Range Timer - 4PCO
H3YN-4-24DC
H3YN-4-100/120AC
H3YN-4-200/230AC
986-896
986-902
986-914
1+
DPCO PCB
4PCO Surface/DIN rail
4PCO Chassis
118-1252●
134-0953●
427-342
Retaining Clips
Surface/DIN rail
Chassis/PCB
103-924
424-651
20+
100+
250+
Twin Timer
Voltage range
Time setting range
Multifunction/
H3DS-AL/H3DS-XL
H3DS-FL
H3DS-GL
Contact rating
12 to 240V ac/dc operation
Adjustable transfer time 0.05 to 1 sec
4 time range scales 0.1 sec to 20 min
High input/output isolation
LED status indicator
Slim 17.5mm wide enclosure
35mm rail mount
40
234843
Price Each
12 - 240VAC/dc Transfer Time
2NO (SPDT)
Repeatability
6/10A
Recovery Time
250/400 V ac Setting Accuracy Full Range
0.05 to 1 Sec
±1%
50ms Max.
±5%
1500 VA
300 VA
0.1 to 2 sec
1 to 20 sec
0.1 to 2 min
1 to 20 min
60,000 Cycles
-10 to 50°C
IP20
Electrical Life at Rated Load AC1
Ambient Temperature
Protection Category
Terminal Type
Mftrs. List No.
Order Code
Multifunction- 4 mode
Screw
H3DS-SL
377-4168
Multifunction- 8 mode
Screw
H3DS-ML
377-4156
Delay on Energisation
Screw
H3DS-AL
377-4170
Y92-S38
377-4181
1+
Locking Tool
Time Relays
475898
Price Each
Supply Voltage
Mftrs. List No.
Order Code
12 - 240VAC/dc
80.82.0.240.0000
134-4238●
1+
5+
10+
5+
10+
Process Control, Timers & Counters
Nominal Supply Voltage
Output
Rated Current/Max Peak Current
Rated Voltage/Max Switching Voltage
Rated Load AC1
Rated Load AC15
Time Ranges
A: ON delay, B2: Recycling ON start, E: Interval, J: One shot
A: ON delay, B: Recycling OFF start, B2: Recycling ON start
C: Signal ON/OFF, D: Signal OFF delay, E: Interval, G: Signal ON/OFF delay
J: One shot
B: Recycling OFF start, B2: Recycling ON start
24 to 230Vac, 24 to 48Vdc
0.1s - 1.2s to 10hr - 120hr
1.0s to 12hr
up to 120s
SPDT 5A @ 250Vac/30Vdc, Star Delta 2XSPST-NO,
Two Wire in line SCR 0.7A max
Operating temperature -10°C to +55°C
Multi-Range Multi-Voltage Star Delta Timer
Ì
Ì
Ì
Ì
Ì
Ì
Ì
4 Mode
8 Mode
Automation
24VDC
110VAC
230VAC
sockets
Ì Each unit features a wide supply voltage range and large capacity outputs
Ì Available with standard screw terminals or Screw-less Clamp connections.
Ì Clamp terminal connections offer fast, repeatable connections which double for major
terminals to allow for parallel operation.
Minature plug-in Timers
86 Series
Controls
Indicators (LED’s)
Functions
2 Time Function
Time Ranges
Ì 4 Timing functions
Ì 7 Overlapping time scales - 0.05s to 100h
Ì Three stat LED indicator
Ì High output switching capacity
Ì 94 Series sockets available separately
621888
Adjustment Range
Control Input
Remote Potentiometer
Supply
Output
Width
Certificates
1250704
1250707
G2ZIF20 24-240VAC/DC
Time1 - Time2 - Function
U/t1 - t2 - R
lp - li - ER - EWu
EWs - WsWa - Wt
Yes
1 - 3 - 10 - 30s
1 - 3 - 10 - 30min
1 - 10h
5% - 100%
Terminals Y1-Y2
Galvanic Seperated
Time1: Terminals Z1-Y2
Time2: Terminals Z2-Y2
24 to 240V ac/dc
Terminals A1-A2
2 CO contacts
250V, 5A ac
22.5mm
CE - UL - cUL - GOST
G2ZI20 12-240VAC/DC
Time1 - Time2 - Function
U/t - R
lp - li - ER - EWu
EWs - WsWa
Yes
1 - 10s
1 - 10min
1 - 10 - 100h
5% to 100%
Terminals A1-B1
Loadable
12 to 240V ac/dc
Terminals A1-A2
2 CO contacts
250V, 5A ac
22.5mm
CE - UL - cUL
2945
2946
farnell.com
Ì Multi voltage, Multi function
Ì Six time scales, from 0.1s to 10h
Ì 4 functions with supply start, 3 with signal start Ì 35mm rail (EN 50022) mount
Multirange Electronic Timers - continued
Time Relays - continued
445138
Price Each
Mftrs. List No.
Order Code
G2ZIF20 24-240V
G2ZI20
Remote Potentiometer
125-0704●
125-0707●
125-0708●
1+
5+
element14.com
10+
Coil operating voltage
Contact configuration
Rated current/Max. peak current
Rated voltage/Max.switching voltage
Rated load - AC1
Rated load - AC15 (230V ac)
Single phase motor rating (230V ac)
Breaking capacity - DC1: 30/110/220VA
Minimum switching load
Contact material
12 to 230V ac/dc
SPCO
16/30A
250/400V
4000 VA
750 VA
0.55 kW
16/0.3/0.12
500 mW (10V/5mA)
AgCdO
246409
Mftrs.
Multifunction, D6 Series
Price Each
List No.
DIN Rail Mounting
Order Code
81.01.0.230.0000
Multifunction
Ì 8 functions
Ì 8 time ranges
Ì Indication of timing period
Ì Integrated voltage selector
Ì 1 C/O contact
Ì Operating voltage 24V ac/dc or 110-240V ac
True Off-delay
Ì 4 time ranges
Ì Integrated voltage selector
Ì 1 C/O contact
Ì Operating voltage 24V ac/dc or 110-240V ac
H = 64, W = 22.5, D = 75
Operating Modes:
Automation
40
Time ranges:
Contact arrangement:
Contact rating:
Temperature:
Multifunction
E On DelayD6DM
R Off Delay
1,10 Secs, mins, hrs, days
SPCO
8A @ 240Vac
-25°C to +55°C
25+
Modular - DIN rail mount
Ì
Ì
Ì
Ì
Ì
80.01, 80.11, 80.21, 80.41
1,10 secs 1, 3 mins
SPCO
5A @ 240Vac
-2555
Mono and Multi function versions available
6 time scales, from 0.1s to 20h
Rotary selector
High input/output insulation
35mm rail (EN 50022)mount
5+
10+
25+
80.91
Series Functions
80.01
223063
1+
10+
80 Series
Price Each
List No. Order Code
5+
True OFF-Delay
True off delayD6DA
Mftrs.
Timing Function
1+
426-9020
50+
Multifunction
D6DM 325-6509
Asymmetric flasher, 1 CO D6DI 125-0709●
Star-Delta, 2 NO
D6DS 125-0710●
Single Function Electronic Staircase Timer
80.11 80.21 80.41 80.91
A1 ON delay
D1 ON pulse
SW Symmetrical recycler, ON start
BE Signal OFF delay
CE Signal ON and OFF delay
DE Signal ON pulse
A1
Contact configuration
Rated current/Max. peak current
Rated voltage/Max.switching voltage
Rated load - AC1
Rated load - AC15 (230V ac)
SPCO
Single phase motor rating (230V ac)
16/30A Breaking capacity - DC1:
250/400V 30/110/220VA
4000 VA Minimum switching load
750 VA Contact material
D1
BE
L1 Asymmetrical recycler (ON starting)
LE Signal asymmetrical recycler (ON starting)
0.55 kW
16/0.3/0.12
500 mW (10V/5mA)
AgCdO
246413
Process Control, Timers & Counters
Nominal Supply Voltage
Output
Rated Current/Max Peak Current
Rated Voltage
Rated Load AC1
Rated Load AC15
Nominal Lamp Rating (230V ac)
230VAC, 50/60 Hz
1NO SPST
16/30A (120A 5ms)
230VAC
3700 VA
750 VA
3000W Incandescent
1000W Compensated Fluorescent
1000W Uncompensated Fluorescent
3000W Halogen
Electrical Life at Rated Load AC1
100,000 Cycles
Delay Time Setting
30 sec to 20 min adjustable
Max. No. of Illuminated Pushbuttons 30
Ambient Temperature
-10 to 60°C
Protection Category
IP20
Ì
Ì
Ì
Ì
Ì
Ì
Coil Operating
Mftrs.
Voltage
List No.
Price Each
Order Code
1+
5+
10+
25+
100+
Multi function - Multi voltage
12 to 240V ac/dc80.01.0.240.0000426-8945
Mono function -Mono voltage
24 to 240V ac/dc80.21.0.240.0000134-4235●
Mono function - Multi voltage
12 to 240V ac/dc80.91.0.240.0000426-9019
Multifunction - DIN rail mount
87 Series
30 sec to 20 min time setting
Zero crossing load switching
Can be used with illuminated pushbuttons
LED status indicators
Slim 17.5mm wide enclosure
35mm rail mount
Ì
Ì
Ì
Ì
Multi function
Time scales from 0.05s to 60h
LED indicator
35mm rail (EN 50022) mount
475780
Mftrs.
Price Each
List No.
Order Code
14.71.8.230.0000
134-4200●
1+
5+
10+
Multifunction - DIN rail mount
81 Series
Series Functions
87.01
Series Functions
A1 ON delay
D1 ON pulse
SW Symmetrical recycler, ON start
SP Symmetrical recycler, OFF start
BE Signal OFF delay
DE Signal ON pulse
EE Signal OFF pulse
87.91
A1 ON delay
D1 ON pulse
G1 Fixed pulse delayed
SW Symmetrical recycler, ON start
BE Signal OFF delay
CE Signal ON and OFF delay
DE Signal ON pulse
EE Signal OFF pulse
L1 Asymmetrical recycler (ON starting)
P1 Asymmetrical recycler OFF starting
LE Signal asymmetrical recycler (ON starting)
PE Signal asymmertical recycler OFF starting
246491
Price Each
Mftrs. List No.
87.01.0.240.0000
87.91.0.240.0000
2946
Order Code
418-1323
418-1414
1+
5+
10+
25+
farnell.com
Multifunction/Monofunction
DIN Rail Mounting 17.5mm/22.5mm-Chronos 2
Ì 17.5 slimline or 22.5mm DIN
rail mounting
Ì Multi-function, Dual-function or
Mono-function
Ì Multi-range (0.1s to 100 hours)
Ì Multi-voltage by 2 terminals
Ì Output: 1 or 2 changeover relays 8 A @ 250V
Ì LED Status indicators
Ì Possible to connect external
power supply to the control input
Ì 3 wire sensor control option
Ì Precision timing by micro-controller
223100
Price Each
Voltage
Function Order Code
U
120-6976●
24VDC, 24 to 240 VAC
24VDC, 24 to 240 VAC
24V, 24 to 240 VAC
24V, 24 to 240 VAC
24VDC, 24 to 240VAC
24V dc, 24 to 240VAC
24VDC, 24 to 240VAC
U
A/At
B
C
U
A/At
L/Li
120-6978●
120-6979●
120-6980●
120-6981●
120-6969●
120-6971●
120-6972●
22.5mm-DPCO
24VDC, 24 to 240VAC
24VDC, 24 to 240VAC
24VDC, 24 to 240VAC
K
U
X
120-6973●
120-6974●
120-6975●
5+
10+
20+
Ì A wide AC/DC power supply ranges
Ì Finger-safe terminal block and captive screws according to EN 50274
Ì EMC (EN 61812-1) compliance for application in heavy industrial, residual, commercial
or light industrial environments
Ì CE and LR Approved, UL Recognised
623927
Supply Voltage
Mftrs.
Range
List No.
24V AC to 240V AC, 24V H3DK-G AC/DC24-240
DC to 240V DC
12V DC
H3DK-GA DC12
240V AC to 440V AC
H3DK-GE AC240-440
621891
Price Each
Order Code
88 867 105
120-6966●
11 Pin plug-in base
12 to 240V ac/dc
24VDC / 24 to 240VAC
Solid State Timers
H3DK Series
10+
187-0016●
187-0017●
187-0018●
187-0019●
187-0020●
Power OFF-delay Timer
Timer Range - 0.1s to 12s
24V DC to 48V DC
H3DK-HBS AC/DC24-48
187-0022●
100V AC to 120V AC
200V AC to 240V AC
187-0024●
187-0027●
H3DK-HCS AC100-120V
H3DK-HDS AC200-240V
Timer Range - 1s to 120s
24V DC to 48V DC
100V AC to 120V AC
200V AC to 240V AC
H3DK-HBL AC/DC24-48
H3DK-HCL AC100-120V
H3DK-HDL AC200-240V
187-0021●
187-0023●
187-0025●
Multi-range, Multi-mode Timer
4 Mode Timer - SPDT Output
24V AC to 240V AC, 24V H3DK-S1 AC/DC24-240
DC to 240V DC
12V DC
H3DK-S1A DC12
187-0032●
187-0033●
4 Mode Timer - DPDT Output
24V AC to 240V AC, 24V H3DK-S2 AC/DC24-240
DC to 240V DC
12V DC
H3DK-S2A DC12
187-0034●
187-0035●
8 Mode Timer - SPDT Output
24V AC to 240V AC, 24V H3DK-M1 AC/DC24-240
DC to 240V DC
12V DC
H3DK-M1A DC12
187-0028●
187-0029●
8 Mode Timer - DPDT Output
24V AC to 240V AC, 24V H3DK-M2 AC/DC24-240
DC to 240V DC
12V DC
H3DK-M2A DC12
187-0030●
187-0031●
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
H = 45, W = 35, D = 87mm
Mftrs. List No.
5+
40
Programmable Time Switch
Precision timing by micro-controller
8 or 11 pin plug in modules available
Multi, Dual or Mono - Function
7 Timing ranges from 0.1s to 100h
Output relay 8A @ 250V
LED Status indicator
3-wire sensor control option
8 Pin plug-in base
24VDC / 24 to 240VAC
1+
Star-delta Timer
8 and 11 Pins - Chronos 2
Voltage
Order Code
Twin Timer - Flicker OFF start or Flicker ON start
24V AC to 240V AC, 24V H3DK-F AC/DC24-240
DC to 240V DC
12V DC
H3DK-FA DC12
Plug-in Electronic Timers
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Price Each
1+
5+
10+
Supply Voltage
Power Consumption
Channel (potential-free)
Contact Material
Switching Capacity
Minimum Interval
Power Back-Up (at 20°C)
Display
Permissible Ambient Temp.
Enclosure
Type of Connection
Type of Protection
1 or 2 Channels
Switching capacity 16 A per channel
Permanent by date-mode(holiday function)
Manual override
Elapsed time and pulse counter for each channel
Security by PIN-Coding
Unlimited program security by E2-Prom
Can be programmed with supply disconnected
>6 years power back up
Din-rail mounting
Daily and Weekly program
60 memory locations
Automatic sorting of switching times on readout
Unrestricted block programming of days
Fully automatic daylight saving time (European, North
American or Australian standard adjustable)
250V, 50-60Hz
1.5VA
Change-over, contact gap < 3 mm (μ)
AgSnO2
16A / 250V
1 min.
approx. 6 years (depends on the Lithium-battery life)
high resolution LCD (visible area 7.5 cm2)
-10°C to 55°C
Self-extinguishing thermoplastic
Screw Terminals (pull-up type)
IP 20 to DIN EN 60529
Process Control, Timers & Counters
17.5mm-SPCO
12 to 240VAC/dc
1+
2947
Automation
17.5mm: H=81, W=17.5, D=60
22.5mm: H78, W=22.5, D=95
Multi - function U:
10 function (A, At, B, C, H Ht, Di D, Ac Bw)
Multi - function X:.
8 function (N, O, P W, Ad, Ah, T Tt)
Function A:
Delay on energisation
Function At:
Timing on energisation with memory
Function B:
Timing on impulse one shot
Function C:
Timing after impulse
Function Di:
Symmetrical flip flop, pulse start
Function D:
Symmetrical flip flop. pause start
Function Ac:
Timing after closing and opening of a control contact
Function Bw:
Timing at the closing and opening of the control contact
Function Li:
Asymmetrical flip flop, pulse start
Function L:
Asymmetrical flip flop, pause start
Function K:
Delay on de-energisation
Function N:
Safe-guard
Function O:
Delayed safe-guard
Function P:
Delayed fixed length pulse
Function W:
Timing after pulse on control contact
Function Ad;
Timing on impulse
Function Ah:
Single flip flop on impulse, pause start
Function T:
On/off latch after pulses
Function Tt:
Timed on/off latch after pulses
Operating Temperatre -20°C to +60°C
Mftrs. List No.
88 826 125 = 120-6980,
88 865 155 = 120-6972,
88 826 103 = 120-6976,
88 826 135 = 120-6981,
88 865 265 = 120-6973,
88 826 105 = 120-6978,
88 865 105 = 120-6969,
88 865 305 = 120-6974,
88 826 115 = 120-6979,
88 865 115 = 120-6971,
88 865 385 = 120-6975,
element14.com
512325
Price Each
88 867 303
88 867 455
120-6967●
120-6968●
Description
Order Code
1 Channel
2 Channel
160-7155●
160-7156●
1+
3+
5+
IMPROVED BACK ORDER DELIVERY
Receive email updates with the exact status, due
date and despatch information of all your back
order items farnell.com
2947
2948
farnell.com
Ì
Ì
Ì
Ì
Multirange Electronic Timers - continued
Multifunction (4) Timer
Ì 4 supply initiated functions:- Delay On Operate, Interval, Symmetrical Recycling On/Off, Symmetrical
Off/On
Ì Dual voltage
Ì Multi time range (to 60 minutes)
Ì SPDT relay output (8A)
Ì LED indication of supply and relay status
Ì DIN rail or surface mounting
Ì 17.5mm wide
Supply voltage Un
H = 89, W = 17.5, D = 59
24V ac/dc / 110V ac 48 - 63Hz
24V ac/dc / 230V ac 48 - 63Hz
Supply variation
85 - 115% of Un
Power consumption (@ 1.15 x Un) AC: 3VA (110V), 13VA (230V)
DC: 0.6W (24V)
Time delay
Seconds: 0.5 - 15, 2 - 60
Minutes: 0.2 - 8, 2 - 60
Repeat accuracy
±0.5% at constant conditions
Reset time
100mS
Ambient temperature
-20 to +60°C
Output
SPDT relay
Output rating
AC1 - 250V ac 8A (2000VA)
AC15 - 250V ac 5A (no), 3A (nc)
DC1 - 25V dc 8A (200W)
Electrical life
≥150,000 ops @ rated load
Housing (UL94-V0)
Orange flame retardant
Weight
66g
Terminal conductor size
≤ 2x 2.5mm2 solid or stranded
element14.com
Single function
Dual voltage
Single time range
SPDT relay output (8A)
Ì
Ì
Ì
Ì
LED indication of supply status
DIN rail or surface mount
17.5mm wide
UL recognised and CUL approved
381710
Time
Price Each
Delay
0.5 - 10 sec
2 - 60 sec
0.5 - 10 min
0.5 - 10 sec
Mftrs. List No.
Order Code
M1EDF24/230V 10SECS
M1EDF24/230V 60SECS
M1EDF24/230V 10MINS
M1EDF 24/110V 10SECS
851-9536
851-9544
851-9552
851-9560
1+
5+
10+
Zelio Time Tamper-proof ON-delay Timer
(RE7T)
Ì ON-delay timer
Ì Protection of settings with sealable transparent
cover
Ì Wide time range
Ì 8A relay outputs (1 or 2)
Ì Option for second output to be instantaneous
Ì LEDs indicating relay energisation and time delay
Ì Wide-range supply voltage
Ì External setting of time delay with potentiometer
(RE7TP)
Ì Printed timing and wiring diagrams on side
Ì Very compact
H=78, W=22.5, D=80
381711
Automation
Price Each
Mftrs. List No.
Order Code
M1MFT 24/230V
M1MFT 24/110V
1+
5+
Supply Voltage
24V - 110VAC to 240VAC
Relay output
1 or 2 (8A) c/o relays
Adjustable time delay 0.05s - 300hrs over 10 time ranges
Contact material
AgNi
10+
851-9498
851-9501
Ambient temperature -20°C to 50°C
Ingress protection IP50
Standards
IEC 61812-1
Approvals
UL Recognised, CSA and
CE approved
247968
Multifunction (6) Timer
Price Each
Supply Voltage Un
Supply variation
Power consumption (@
1.15 x Un)
40
Time delay
Process Control, Timers & Counters
Repeat accuracy
Reset time
Ambient temperature
Output
Output rating
Electrical life
Housing (UL94-V0)
Weight
Terminal conductor size
Output
24V ac/dc / 110V ac 48 - 63Hz
24V ac/dc / 230V ac 48 - 63Hz
85 - 115% of Un
AC: 0.4VA (24V), 2.3VA (110V),
4.8VA (230V)
DC: 0.58W (24V)
Seconds: 0.5 - 60
Minutes: 0.5- 60
±0.5% at constant conditions
100mS
-20 to +60°C
SPDT relay
AC1 - 250V ac 8A (2000VA)
AC15 - 250V ac 5A (no), 3A (nc)
DC1 - 25V dc 8A (200W)
≥150,000 ops @ rated load
Orange flame retardant
70g
≤ 2x 2.5mm2 solid or stranded
1 c/o relay
Mftrs. List No.
Order Code
RE7TL11BU
423-3086
1+
5+
10+
Zelio Time Economic - ON-delay Timer
(RE8T)
ON-delay timer
Protection of settings with sealable transparent cover
One 8A relay output
LEDs indicating relay energisation and time delay
Printed timing and wiring diagrams on side
Very compact
Ì
Ì
Ì
Ì
Ì
Ì
H = 89, W = 17.5, D = 59
Ì 2 supply / 4 switch initiated functions:- Delay On Operate (2 switch / 1 supply initiated), Interval (1 switch or 1 supply initiated), Delay Off (switch only initiated)
Ì LED indication of supply and relay status
Ì Dual voltage
Ì DIN rail or surface mounting
Ì Multi time range (to 60 minutes)
Ì 17.5mm wide
Ì SPDT relay output (8A)
381712
H = 78,
W= 22.5,
248137
Price Each
Mftrs. List No.
M1SMT 24/230V
Order Code
1+
5+
D = 80
Supply Voltage
24V, , 110VAC to 240VAC Ingress protection IP50
Relay output
8A c/o relay
Standards
IEC 61812-1
Contact material
AgNi
Approvals
UL Recognised, CSA and CE approved
Ambient temperature -20°C to 50°C
Mftrs.
10+
851-9510
Price Each
Time Range
List No.
Order Code
0.1 - 10secs
0.3 - 30secs
RE8TA11BU
RE8TA31BU
423-3232
423-3244
1+
5+
10+
True Delay Off (Delay On Release)
Supply / monitoring voltage Un
24V ac/dc / 110V ac 48-63Hz
24V ac/dc / 230V ac 48-63Hz
Supply variation
85 - 115% of Un
Power consumption (@ 1.15 x Un) AC: 1.3VA (24V), 2.7VA (110V),
12.8VA (230V)
DC: 0.62W (24V)
Time Delay
Seconds: 0.5 - 10, 2 - 60
Minutes: 0.5 - 10
Repeat accuracy
± 0.5% at constant conditions
Reset Time
100mS
Ambient temperature
-20 to +60°C
Output
SPDT relay
Output rating
AC1 - 250V ac 8A (2000VA)
AC15 - 250V ac 5A (no), 3A (nc)
DC1 - 25V dc 8A (200W)
Electrical life
100,000 ops @ rated load
Housing (UL94-V0)
Orange flame retardant
Weight
73g
Terminal conductor size
≤ 2x 2.5mm2 solid or stranded
H = 89, W = 17.5, D = 59
2948
RTMA miniature 2 & 4 Pole Plug-In Timer
Ì Mono-function delay on energisation
Ì Multi-range (0.1s to 100 hours in 7 selectable ranges)
Ì Excellent noise resistance
Ì Output: 2 or 4 timed changeover relay 5A @ 230V
Ì Option to select instantaneous relay output
Ì 2 LED status indicators
Ì Precision timing by micro-controller
Ì cUL approved and UL recognised
Dimensions
Operating Temperature
21x27x69mm
-20 to 60°C
Weight
Supply Voltages
55g
12V dc, 24V dc, 24V ac,
110V ac, 240V ac
7 ranges from 0.1s to 100Hr
Time Ranges
Dimensions
Contacts
21x27x69mm
2 or 4 x SPDT 5A
@ 230V ac resistive
Max Reset Time 250 ms
Electrical Life
>100,000 ops
@ 5A/240V ac resistive
farnell.com
Relay
Outputs
2 Timed Changeover
2 Timed Changeover
4 Timed Changeover
4 Timed Changeover
4 Timed Changeover
Type
RTMA2
RTMA2
RTMA4
RTMA4
RTMA4
Supply
Voltage
12VDC
24VAC
24VDC
110VAC
230VAC
Mftrs.
List No.
88 895 201
88 895 203
88 896 202
88 896 206
88 896 207
Order Code
790-8482
790-8504
790-8547
790-8563
790-8571
348893
Mftrs.
Price Each
Voltage
List No.
Timers
12VDC
Order Code
88 895 201
790-8482
24VAC
24VDC
110VAC
230VAC
88 895 203
88 896 202
88 896 206
88 896 207
790-8504
790-8547
790-8563
790-8571
1+
5+
10+
25+
DIN rail mounting base
14 pin for RTMA4
26 532 706
790-8598
Electronic timer in 48 DIN housing with rear connections compatible with standard 8-pin relay socket. Can
be panel mounted, base and DIN rail mounted using relay socket accessories.
Delay on energisation
Repeat Accuracy
12 to 240VDC /
24 to 240VAC
14 ranges from 0.2s to 300Hr
2 x SPDT 5A
@ 230V ac resistive
Max Reset Time 100ms
Supply Voltage
Electrical Life
Time Ranges
Contacts
Operating Temperature
Weight
348895
Price Each
Description
Mftrs. List No.
TMR48L
88 886 516
±0.5% of
set value @ 25°C
100000 ops
@ 5A/240V ac resistive
-20°C to 50°C
140g
790-8644
25 622 080
790-8679
88 886 106
790-8652
Accessories
8 Pin Relay Base
25 622 130
790-8660
Order Code
1+
5+
10+
25+
10+
25+
Supply Voltage
Functions
8 functions (A, B, C, H, W, G, Ac, Bw)
Delay on energisation
Timing on impulse one shot
Timing after impulse
Timing on energisation (select function B and link pins 2 and 6)
Timing after pulse on control contact
Repetitive cycle percentage timer pause start
Timing after closing & opening of control contact
Timing at the closing & opening of control contact
12 to 240VDC /
24 to 240VAC
14 ranges from 0.02s to
300Hr
2 x SPDT 5A
@ 230V ac resistive
100ms
Repeat Accuracy
Operating Temperature
±0.5%
of set value @ 25°C
100000 ops
@ 5A/240V ac resistive
-20°C to 50°C
Weight
140g
Electrical Life
Connections
Pin 1 Common for contact A
Pin 2 Supply (negative if DC)
Pin 3 N/O contact A
Pin 4 N/C contact A
Pin 5 Timing inhibit gate (negative if DC)
Pin 6 Control input (negative if DC)
Connections
Pin 7
Reset input (negative if DC)
Pin 8
N/C contact B
Pin 9
N/O contact B
Pin 10 Supply (positive if DC)
Pin 11 Common for contact B
348896
Price Each
Description
TMR48L Analogue Panel Mounting
Electronic Timer
Electronic timer in 48 DIN housing with rear
connections compatible with standard 11pin relay socket. Can be panel mounted,
base and DIN rail mounted using relay socket accessories.
48x48 DIN case, 45 x 45 cut-out, D. Bezel &
Knob 16.8, D. behind bezel 80
Multi Function
Function L
Function Li
Function G
Function Gi
Supply Voltage
Multi Function
Function A
Function B
Function C
Function H
Function W
Function G
Function Ac
Function Bw
Max Reset Time
348894
Mftrs. List No.
5+
Electronic timer in 48 DIN housing with
rear connections compatible with standard 11-pin relay socket. Can be panel
mounted, base and DIN rail mounted using relay socket accessories.
Ì Multi-function (8 functions with optional timing inhibit gate)
Ì Multi-range (0.02s to 300 hours in 14
ranges)
Ì 12 to 240V dc, 24V ac to 240V ac
multi-voltage on 2 pins
Ì Output: 2 timed changeover relay 5A
@ 230V
Ì 2 LED status indicators
48x48 DIN case, 45 x 45 cut-out, D. Bezel & Knob 16.8,
Ì Gate inhibit on all timing functions
D. behind bezel 80
Ì Precision timing by micro-controller
Contacts
Price Each
TMR48A
1+
Accessories
Time Ranges
Connections
Pin 5
N/C contact B
Pin 6
N/O contact B
Pin 7
Supply (positive if DC)
Pin 8
Common for contact B
Description
Order Code
Contacts
2 x SPDT 5A
@ 230V ac resistive
Max Reset Time 100ms
Connections
Common for contact A
Supply (negative if DC)
N/O contact A
Pin 4
Pin 5
Pin 6
Order Code
790-8628
25 622 080
790-8679
Repeat Accuracy
Operating Temperature
±0.5%
of set value @ 25°C
100000 ops
@ 5A/240V ac resistive
-20°C to 55°C
Weight
140g
Electrical Life
Connections
N/C contact A
Timing inhibit gate (negative if DC)
Connect to pin 2 for pulse start
1+
5+
10+
25+
TMR48X Analogue Panel Mounting
Electronic Timer
Ì Multi-function (4 functions with optional
timing inhibit gate)
Ì Multi-range (0.02s to 300 hours in 14
ranges)
Ì 12 to 240V dc, 24V ac to 240V ac multivoltage on 2 pins
Ì Output: 2 timed changeover relay 5A @
230V
Ì 2 LED status indicators
Ì Gate inhibit on all timing functions
Ì Precision timing by micro-controller
Functions
4 functions (L, Li, G, Gi)
Asymmetrical recycler pause start
Asymmetrical recycler pulse start
Repetitive cycle percentage timer pause start
Repetitive cycle percentage timer pulse start
12 to 240VDC /
24 to 240VAC
14 ranges from 0.02s to 300Hr
Accessories
11 Pin Relay Base
Mftrs. List No.
88 886 016
Electronic timer in 48 DIN housing with rear
connections compatible with standard 8-pin
socket. Can be panel mounted, base and DIN
rail mounted using relay socket accessories.
48x48 DIN case, 45 x 45 cut-out, D. Bezel &
Knob 16.8, D. behind bezel 80
40
Process Control, Timers & Counters
Connections
Pin 1
Common for contact A
Pin 2
Supply (negative if DC)
Pin 3
N/O contact A
Pin 4
N/C contact A
Connections
Supply (positive if DC)
Common for contact B
Automation
Ì Mono-function delay on energisation
Ì Multi-range (0.02s to 300 hours in 14 ranges)
Ì 12 to 240V dc, 24V ac to 240V ac multi-voltage on
2 pins
Ì Output: 2 timed changeover relay 5A @ 230V
48x48 DIN case, 45 x 45 cut-out, D. Ì 2 LED status indicators
Bezel & Knob 16.8, D. behind bezel 80 Ì Precision timing by micro-controller
Function A
Pin 10
Pin 11
2949
TMR48U Analogue Panel Mounting
Electronic Timer
TMR48A Analogue Panel Mounting
Electronic Timer
Pin 1
Pin 2
Pin 3
Connections
Connect to pin 2 for function G
N/C contact B
N/O contact B
11 Pin Relay Base
Accessories
Time Ranges
Pin 7
Pin 8
Pin 9
element14.com
Ì Multi-function (8 functions with optional
timing inhibit gate)
Ì Multi-range (0.02s to 300 hours in 14
ranges)
Ì 12 to 240V dc, 24V ac to 240V ac multivoltage on 2 pins
Ì Output: 1 timed & 1 instantaneous changeover relay 5A @ 230V
Ì 2 LED status indicators
Ì Precision timing by micro-controller
Functions
Multi Function
7 functions (A1, A2, H1, H2, Q1, Q2, D, Di)
Function A1
Delay on energisation, with instantaneous contact
Function A2
Delay on energisation, 2 contacts
Function H1
Timing on energisation, with instantaneous contact
Function H2
Timing on energisation, 2 contacts
Function Q1
Star-delta, type 1
Function Q2
Star-delta, type 2
Function D
Symmetrical recycler pause start
Function Di
Symmetrical recycler pulse start
Supply Voltage 12 to 240VDC /
Repeat Accuracy ±0.5% of
24 to 240VAC
set value @ 25°C
Time Ranges
14 ranges from 0.02s to 300Hr Electrical Life
100000 ops
Contacts
2 x SPDT 5A
@ 5A/240V ac resistive
@ 230V ac resistive
Operating Temp. -20°C to 55°C
Max Reset Time 100ms
Weight
140g
2949
2950
farnell.com
Timer
Multirange Electronic Timers - continued
Price Each
Plug-in Analogue Timer
88 886 116
790-8636
Order Code
25 622 130
790-8660
1+
5+
10+
25+
Accessories
8 Pin Relay Base
Order Code
On Delay - 0.05s to 300h H3CR-A8 100-240AC/100125VDC
On Delay - 0.05s to 300h H3CR-A8E 24-48VAC/VDC
On Delay - 0.05s to 300h H3CR-A8E 100-240VAC/100125VDC
348919
Mftrs. List No.
Mftrs. List No.
8-Pin Versions
On Delay - 0.05s to 300h H3CR-A8 24-48VAC/12-48VDC
Connections
Pin 5
N/C contact B
Pin 6
N/O contact B
Pin 7
Supply (positive if DC)
Pin 8
Common for contact B
Description
Price Each
Function - Range
TMR48X Analogue Panel Mounting
Electronic Timer - continued
Connections
Pin 1
Common for contact A
Pin 2
Supply (negative if DC)
Pin 3
N/O contact A
Pin 4
N/C contact A
element14.com
1+
5+
10+
313-7983
313-7971
313-7995
313-8008
11-Pin Versions
Multifunction - 0.05s to
300h
Multifunction - 0.05s to
300h
Recycling - 0.05s to 30h
Recycling - 0.05s to 30h
H3CR-A 24-48VAC/12-48VDC
313-7960
H3CR-A 100-240VAC/100125VDC
H3CR-F8 24AC/DC
H3CR-F8 100-240AC
313-7958
560-558
560-560
P2CF08
Y92F-30
330-954●
104-636
Accessories
Digital Multifunction - H3CAA
Ì DIN48 body size
Ì Eight operating modes and selectable time range
between 0.1s and 9.99 hours
Ì Programmed via five front panel ’fold down’ push
rotary switches
Ì LCD bar display indicates remaining time and
control output status
Ì Separate mounting adaptor available for front
panel mounting
Ì CSA and SEV approved
Ì UL Recognised
Automation
Operating mode
Time ranges
Eight selectable
Contact rating
Selectable between 0.1s Operating voltage
to 9990hr full scale
±0.3%
0.5s max.
SPCO
Operating voltage range
Repeat accuracy
Reset time
Contact
Price Each
40
TimerH3CA-A-306
Chassis socket
Panel mounting adaptor
1+
5+
10+
175-532
118-1273●
104-636
Process Control, Timers & Counters
On-Delay - H3AM
Large Display
Ì Large easy to read display
Ì Wide supply voltage 100 to 240Vac
Ì Different coloured moving pointers indicates both set and remaining times
Ì Wide time ranges (three units cover 0.2s
to 60h)
Ì User configurable output configuration
Ì Sealed to IP65
Ì Manual setting knob
Ì Conforms to IEC61812-1, IEC60664-1
Ì UL Recognised and CSA approved
H = 96, W = 96, D = 85 behind bezel
Operating modes ON delay
Time ranges
186-041 (30s, 3 min, 30 min, 3h, 30h)
186-053 (60s, 6 min, 60 min, 6h, 60h)
186-065 (12s, 120s, 12 min, 120 min, 12h)
-
Operating voltage
Operating temperature
Contact rating
Reset input time
Power reset time
contact arrangement
Digital, Programmable
LED Display
3A @ 250V ac resistive
24 to 240V ac or
12 to 240V dc across
same input terminals
2+10
90-110%
223094
Order Code
8-pin Socket
Panel Mount Adaptor
H=33, W=75, D=69, Panel cut-out=71x29
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì 9 programmable modes of operation
Ì Bright green LED display ensures
clarity of view, even at distance
Ì 5 timing ranges from 1 sec. to
100 hrs., including a 24 hr. range
Ì Two tier access code for program security plus tamper proofing
Ì Selectable up/down timing
Ì Programmable buzzer on output
option
LED indication of timing ranges and output status
2 independent output relays
Programmable reset functions
Remote hold and reset functions
IP65 water and dust protection
CE compliance for both EMC and Low voltage directives
12V ac/dc supply voltage can be provided by optional transformer
Supply Voltage
Power consumption
Contact rating
Reset time
Ambient temperature
CE approvals
12/24V ac/dc ±10%
3VA max.
0/P1 : 8A @ 240Vac resistive, O/P: 5A @ 240Vac resistive
100ms max.
Working : 0 to 50°C, Storage : -10°C to 70°C
Complies with EMC EN50081-1, EN50082-1 & low voltage
EN61010-1 standards
223167
Mftrs.
Timer
Transformers
240Vac to 12Vac
Price Each
List No.
Order Code
TT32ML
767-074
TRA12UN100
645-400
1+
5+
10+
25+
Digital Multifunction - UDT
LCD
100 - 240Vac 50/60Hz
-10°C to + 55°C
5A, 250Vac
0.5 sec
0.5 sec
SPCO
H=48, W=48, D=75,
Panel cut-out=45 sq.
223090
Price Each
Time range
1s to 60hrs
0.2s to 12hrs
Mftrs. List No.
Order Code
H3AM-NS-B300
H3AM-NS-C300
186-053
186-065
1+
5+
10+
Solid-state Timer - H3CR
DIN 48 x 48 Multifunction
Ì Lloyds/NK approvals
Ì Conforms to EN61812-1 and EN60664-1 (VDE0110)
4kV/2 for Low Voltage and EMC Directives
Ì UL Recognised and CSA Approved
Ì Six-language instruction manual provided
621914
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Six operating modes and six time ranges between 0.1s and 99.9hrs
Programming via two front panel switches, includes battery backup
Digital LCD displays up or down count
Enable input may be used to trigger timing
Tamper proof range and mode settings
Cyclic mode on and off settings can be set independently
Accepts wide ac or dc input voltage range and has 7A SPCO relay output
Supplied with panel mounting bracket
Operating Modes
Time ranges
Repeat accuracy
Reset time
Contact
Contact rating
Operating voltage
Operating temperature
Delay on energise, interval, delay on de - energise, delayed cycle
immediate cycle, delayed pulse
9.99s, 99.9s, 9.99m, 99.9m, 9.99hr, 99.9hr.
±0.3% of set time
10ms max.
SPCO
7A @ 240V/30V dc resistive
18 to 264V ac, 47-440Hz, 18-300V dc
-10°C to +60°C
223136
2950
farnell.com
Price Each
Order Code
TimerUDT
DIN rail/surfaceCDRS11
Free, solder (with cover)EDS11F
2951
Operational modes
1+
5+
10+
25+
1+
25+
50+
100+
177-473
Sockets
element14.com
177-177
170-963
Digital Multifunction - 814
ON-delay (5 types)
OFF-delay
One-shot
Flicker
Time Ranges
0.001s - 999.9h (16 time ranges are selectable)
Input
Start, Stop, Reset, Lock
Input Signal
Potential-free contact, start in case of power-on
Output
Relay 1c, 5A 250V ac
Life
2.0x107 operation (mech.),
1.0x105 operation (elec.)
Operating Voltage
12-24V dc/ 24V ac or 100-240V ac
(Range: 84 - 110%)
IP Rating
IP66
Dimensions
48x48x65mm
Operating Temperature
-10°C to +55°C
Front mounting
screw terminal o. 11 pin type + socket AT78051J
DIN-rail mounting
11 pin type + socket ATC180041J
Mounting frame, rubber gasket and instruction manual (in six languages) are included
223084
Price Each
Voltage
Panel cut-out=45 sq.
H=48, W=48, D=79 (behind bezel)
Ì
Ì
Ì
Ì
Ì
Ì
Note: Correct as indicated by dotted links when
using 24V ac/dc supply voltage
Six operating modes and eleven time ranges between 0.01 sec and 9999hrs
Four digit LCD indicates set time, time remaining and output contact status
8A SPCO relay output
Connection is by standard 8 or 11 pin socket
Panel mounting bracket supplied
Sealed to IP64
Operating modes
184-986●
11-pin
Screw
11-pin
184-998●
185-000●
185-012●
AT78051J
ATC180041J
AQM4803J
137-3681●
137-3683●
137-3685●
Rear Terminal Socket
DIN-Rail Socket
Flexible Protective Cover
The Time Cube modules are electronic timers that are designed to be inserted between a standard plug-in relay and
its socket, enabling the relay to be operated as a timer relay.
The CT modules are able to accept any standard 8 or 11 pin
RELECO series C2 or C3 relay as well as those from any
other supplier.
NB - The relay coil voltage must be in the supply voltage
range shown for each model.
223130
Order Code
1+
5+
10+
25+
478-490
478-507
LED Display
Ì Push button rotary switch setting
Ì 4 digit LED display indicates time elapsed
Ì 0.1s to 999.9s or 1s to 99m59s time ranges
available
Ì Memory backup prevents reset on momentary interruption of supply (105-003) and up to 10mins
loss (105-976)
Ì Panel mounting using separate adaptor or surface
mounting using surface/DIN rail socket
Ì UL Recognised and CSA approved
Control Output
Operating Voltage
Y92F-30=104-636
P2CF08=330-954
Mftrs. List No.
0.2s to 30min - ON Delay
20 - 65V ac/dc
CT3-E30/L
279-730
90 - 265V ac/dc
279-742
CT3-E30/H
Timers
Order Code
1s to 99m 59s
105-976
Sockets
Chassis (for 105-003)
Chassis (for 105-976)
Surface/DIN rail
(for 105-003)
Panel mounting adaptor
1+
5+
10+
50+
100+
118-1272●
118-1273●
330-954●
104-636
Digital Multifunction Timer DIN 1/16
LT4H
H=48, W=48, D
(behind bezel)=77
Panel cut-out=45 sq
25+
Ì Synchronous motor operation
Ì Five time ranges selectable via screwdriver slot recessed into timer face
Ì 50/60Hz operation, selectable
Ì Fixed and moving pointers and time out neon indicator
Ì Reset activated by removal of supply voltage
Ì Panel mounting using separate adaptor or 11pin plug-in
mounting
Ì CSA and SEV approved
Ì UL Recognised
Operating Mode
Delay on energisation
Repeat accuracy
±0.5% max.
Reset time
0.5s max.
Contact
SPCO(timed)+SPCO(instantaneous)
Contact rating
3A @ 240V ac
Operating Voltage
110, 230V ac, 50/60Hz
Operating Voltage Range
85-110%
Adjustable time range (selectable)
104630/1:
0-6s, 0-60s, 0-6m, 0-60m, 0-6hr
104632/3:
0-30s, 0-3m, 0-30m, 0-3hr, 0-30hr
223105
Time Range
Ì 2-colour backlight LCD display of elapsed and set time
Ì Easy time setting by seesaw buttons
Ì Cover also in black (please order: timer + cover
ATL58011J)
Ì Power failure memory by EEPROM
Ì Standards: CE, UL, CSA
Ì Installation: front and DIN-rail mounting
10+
Multirange - H2C
SPCO, timed,[email protected]
100VAC-240V, 50/60Hz
PL08=118-1272
PL11=118-1273
Price Each
1+
Electromechanical Timers
223087
Time Range
Order Code
Process Control, Timers & Counters
Price Each
Digital - H5CNLED
Mftrs. List No.
H5CN-XCNM =105-976
40
621927
Supply Voltage
H=48, W=48, D=86 (behind bezel).
Panel cut-out=45sq
25+
Time Cube - CT2 and CT3
Price Each
Connection
10+
Relay Timer Base
Mftrs. List No. 88.857.005=478-490, 88.857.105=478-507
8-pin
11-pin88.857.105
5+
Automation
Repeat Accuracy:
Reset time
Contacts
Operating Temperature
Operating Voltage
Screw
12VDC to 24VDC / 24V ac
100V to 240V
100V ac to 240V ac
1+
Accessories
A: delay on energise, B: single shot (timing on impulse)
C: delay on de-energise, D: recycling (off start),
DI: recycling (on start), A1(H) timing on energise (interval)
11 ranges - 99.99s, 999.9s, 9999s, 99m 59s, 99.99m,
999.9m, 9999m, 99hr 59m, 99.99hr, 999.9hr, 9999hr.
±0.03%±20ms (with constant parameters)
50ms
SPCO(timed) 8Aac/dc250V
-10°Cto +60°C
110 to240Vac 50/60Hz24VDC(+10-15%)
Timing Ranges:
Connection Type Order Code
Relay Output
12VDC to24VDC / 24V ac
Voltage
Timers
Price Each
Order Code
0-6s, 0-60s, 0-6m, 0-60m, 0-6hr
110Vac
0-6s, 0-60s, 0-6m, 0-60m, 0-6hrH2C-SB 240AC 230Vac
0-30s, 0-3m, 0-30m, 0-3hr, 0-30hr
110Vac
0-30s, 0-3m, 0-30m, 0-3hr, 0-30hrH2C-SA 240AC230Vac
104-630
104-631
104-632
104-633
Sockets
Panel mounting adaptorY92F-30
104-636
1+
5+
10+
H=48, W=48,
D=64.5 (screw),
70.1 (11 pin)
2951
2952
farnell.com
Electromechanical Elapsed Hour Counters
Hour Meter
TH6 Series
Supply voltage
Frequency
Counting Range
Min. counting unit
Ambient temperature
Panel thickness
Protection
Dimensions (WxHxD)
Size 24 x 48mm
Digit height 5mm
Conservation of value at power break down
Counting range 0 to 99999,9h and 0 to
9999,9h
Ì With and without reset button
Ì
Ì
Ì
Ì
220V AC ±15%
50/ 60 Hz (switchable)
0 to 99999,9h / 0 to 9999,9h
0,1 hours (6 min)
-10°C to 50°C
1 - 9 mm
IP30, IP40
48 x 24 x 66mm
element14.com
Price Each
Voltage
Order Code
115Vac
240Vac
233-225
233-237
1+
10+
25+
Non-Reset
DIN 43700 Standard
H=48, W=48, D=34
(behind panel)
Ì With rotary indicator
Ì Easy and fast to install with mounting
spring
Ì Frequency 50/ 60 Hz can be selected
Ì For panel thickness of 1 to 9mm
179-379
72x72
514387
Mftrs.
Counting
List No.
TH638CEJ
TH648CEJ
50+
Price Each
Range
Display
With Reset
Order Code
0 to 99999,9h
0 to 9999,9h
-digit
5-digit
Without
With
161-4686●
161-4687●
1+
3+
Panel cut-out=46x46
5+
Panel cut-out using either bezel=51 dia or 46x46
Ì Non-resettable 7-digit motor driven elapsed
hour counters
Ì Housed in Noryl and Makrolon panel
mounting case
Ì Resolution is 0.01hrs for AC types and
0.1hrs for DC types
Ì Decimal digits in red, others in white
Non-Reset - Type 633
Miniature PCB and Panel Mounting
179-378
55x55
Ì Frequency of DC type is controlled by
quartz crystal
Ì 2 bezels available
Ì Supplied with panel mounting bracket
Ì connection by screw or 6.35 (0.25")
fast-on-terminals
223144
Automation
40
PCB Mounting
Pins L=5.5, Dia=0.6 on 0.1" grid
H=14 (excl. pins), W=25, D=31
Connections:
1 +V dc
5 No connection
Panel Mounting
H=20, W=30, D=34 (behind bezel excl. pins)
Panel cut-out = 14.2 x 27
3 Disable output
Connections:
1 +V dc
2 Disable output
2 -0V
5 No connection
7 -0V
Mftrs.
Counters
List No.
24Vac50Hz
110VAC 50Hz
240Vac 50Hz
12-48V dc
55x55mm
72x72mm
BW40.18 24VAC
BW40.18 110VAC
BW40.18 240VAC
BG40.17 12-48VDC
FRAME 55X55
MASK 72X72
Process Control, Timers & Counters
99999.99hr
5-12Vdc ±10%
2mA average, 25mA max.
during pulsing
Pulse duration
Operating temp. Range
31ms every 36s
-10°C to +60°C
Mftrs. List Nos: 0.633.031=233-330, 0.633.831=233-341
223151
Price Each
Order Code
PCB mounting
Panel mounting
1+
10+
50+
Order Code
1+
10+
25+
100+
233-330
233-341
Non-Reset - Type 891
Ì
Ì
Ì
Ì
7-digit electromechanical hour counter
Installation by front plate
Mounting by snap fastener or fork clamp
Electrical connection by screw or 6.35 (0.26") fast-on terminals
Display
7-digit, 99999,99 (AC), 999999,9 (DC)
Approx.4mm high, white on black, red
decimal display
Bezel
55 x 55, 72 x 72 mm
Reading accuracy
AC 1 / 100h = 0,6min = 36s,
DC 1 / 10h = 6min = 360s,
Voltage
24 VAC / 50Hz
100 VAC / 50Hz
220 VAC / 50Hz
10 - 80 VDC
Panel cutout
46 x 46 mm
Panel cutout using either bazel Ø51 mm or 46 x 46 mm
Operating temp.
-20°C…+70°C
Protection
IP41
Dimensions
H = 48 mm, W = 48 mm, D = 32 mm (behind panel)
Weight
51g
247113
Price Each
Panel Mounting
Ì
Ì
Ì
Ì
Ì
Bezel A: 29x54, panel cut-out 25x50
Bezel B: 48x48, panel cut-out 45x45
Current consumption:
Operating temp. Range
Digit height
233-225
233-237
233-225
233-237
Voltage
Mftrs. List No.
Order Code
24VAC
110VAC
240VAC
48VDC
Bezel Adaptor 55 x 55mm
Bezel Adaptor 72 x 72mm
HK4624VAC
HK46110VAC
HK46240VAC
HK4648VDC
HK4655X55
HK4672X72
329-1169
329-1170
329-1194
329-1200
329-1212
329-1224
1+
10+
INTELLIGENT ONLINE BUYING
SYSTEM PROVIDING
Non-resettable 7-digit elapsed hour counters
Synchronous motor drive, resolution 0.01hrs
Polycarbonate housing with spring-fit clip
Two bezels supplied for panel mounting
Connection by screw or 6.3 (0.25") fast-on terminals
Capacity
Supply Voltage
50+
179-374
179-375
179-376
179-377
179-378
179-379
Series HK46
Miniature 7-digit non-reset elapsed hour counters
0.01 hour resolution
Low power consumption
Plastic case with magnifier window
Disable Input allows numerous brief turn-on times without accumulation of times since
last pulse errors (timing pulse = 36 seconds)
Ì PCB version sealed to IP65 and suitable for flow soldering
Ì Panel mount version sealed to IP66 and has solder pin connections
Capacity
Supply Voltage
Current Consumption
Price Each
Electro-mechanical Elapsed Hour Counters
Ì
Ì
Ì
Ì
Ì
H=24, W=48, D=39 (behind panel)
Panel cut-out=22x48 (without bezel)
Complete cost control, reduced
administration time, visibility of your
spend, flexibility and personalised to
your company’s needs.
farnell.com/ibuy
99999.99 hr
110-115Vac ±10% -6%, 50Hz
220-240V ac±10%, 50Hz
4.8mA
3.9mA
-10°C to +50°C
5mm
Mftrs. List No: 0.891.607=233-225, 0.891.606=233-237
223149
2952
Voltage
farnell.com
Electronic Elapsed Hour Counters
element14.com
2953
Electromechanical Counters
Panel Mounting - Type 231
Electromechanical miniature pulse counter
AW15.01/W15.51
Connections:
1 Reset
2 Enable
3 Supply L (common)
4 Supply N
with manual zeroing, adding, 5-digit
H=24, W=48, D=31.5 (overall)
Panel cut-out=22.2x45
Ì Elapsed hour meter housed in DIN case
sealed to IP65
Ì Finger proof protected to IP20
Ì Supply voltage connection permits permanent display
Ì Separate start input connection
Supply Voltage
Display
Operating Temperature Range
Ì Non-volatile memory allows data retention 25yrs minimum
Ì Remote electrical reset facility
Ì Wide temperature range, low power
consumption, high shock resistance
80VAC to 230VAC ±10% 50/60Hz
6 digit LCD, 99999.9hr, 5mm height
-30°C to +65°C
223159
Ì Min. power consumption 130 mW
Ì Ideal for battery operation and electronic circuits
Ì Long life (50 million pulses)
Technical data:
Connection: 2m high-flexible PVC wire radial
Size, digits: appr. 1,7 x 4 mm, Colour, digits: white, black background
Material, axis: stain resistant
Operation temperatur: -10 ... +50 °C
Mounting orientation: variable
No. of digits: 7
Life time: > 50 x 106 Impulses
Weight: AC 52 g, DC 62 g
334503
Price Each
Mftrs. List No.
Order Code
231-5E150-000A
1+
5+
10+
25+
Operation
50+
voltage
516-259
Counter and Elapsed Hour Counter Modules
PCB Mounting Modules
10 Imp/s
472-9778
10 Imp/s
10 Imp/s
472-9780
472-9791
10 Imp/s
472-9808
24V DC
230V DC
24V DC
Ì
Ì
Ì
Ì
Ì
Hours counter
Pulse Counter
40
25+
50+
Max. count frequency
Min. pulse length
[email protected]°C
10Hz
50ms
100%
Temperature Range
Power Consumption
-10°C to +50°C
5V and 12Vdc
24V dc
80mW
160mW
Mfts List No: 0.635.132=925-561, 0.635.128=925-573, 0.635.130=925-585
516-284
516-296
223074
Price Each
Tally Counter
4 Digit Reset
Voltage
Order Code
5VDC
12VDC
24VDC
925-561
925-573
925-585
1+
10+
25+
50+
100+
250+
6 Digit Non-Reset - Type 635
Miniature Panel Mounting
Ì Miniature 6-digit non-reset counters for panel
mounting
Ì Housed in translucent plastic case with magnifier
window
Ì DC types feature high shock resistance with solder
pin connections
Ì 230Vac type has screw terminal connections
H=45, W=31, D=46
Ì
Ì
Ì
Ì
Ì
dc: H=20, W=30, D=34 (behind bezel, excl. pins)
ac: H=20, W=30, D=43 (behind bezel, excl. tmls)
Panel cut-out=14.2x27
Low cost, lightweight, thumb or finger activated counter
High impact, dust and corrosion resistant
4 figures - counts to 9999. High contrast, white or black display figures
Depress thumb lever once for each count. Rotary reset knob on side
Optional mounting base in predrilled for mounting to a desk, bench etc.
223168
Price Each
Hand Tally
Mounting Base
Mftrs. List No.
Order Code
762304-001
300301-547
767-086
767-098
1+
10+
Process Control, Timers & Counters
223162
Price Each
10+
6-digit
IP65 protection
Very low power consumption
Machine solderable and washable
High shock resistance
H=14, W=25.2, D=31
Pin fixing centres=15.2 25.4
Mftrs. List No. CD701-024=516-284, CD703-025=516-296
5+
100+
PCB Mounting - Non Reset
12-48V dc (nom), 9V dc (min), 60V dc (Max.)
6 digit LCD, 99999.9hr/ 999999, 5mm Height
(Hour glass icon and D.P. on hours meter only)
500Hz (pulse counter)
-40°C to +85°C
1+
10+
Totalising Counter - Miniature
Electronic elapsed hour and pulse counters suitable for PCB mounting
Supply voltage connection permits permanent display if required
Non-volatile memory allows data retention for 25yrs
Remote electrical reset facility, wide temperature and voltage range
Low power consumption, high shock and vibration resistance
Order Code
1+
Automation
1.152.011.013
PCB: H=19, W=33, D (above PCB)=5 Pin spacing=14x28
Count Frequency
Operating Temperature
Order Code
1.150.510.013.550
1.150.510.056.550
Note: For proper mechanical support, all 4 pins should be soldered to the PCB.
Supply Voltage
Display
Imp/s
W15.51 - for in-mounting
1.150.510.012.550
12V DC
AW15.01 - for out-mounting
Pin connections
P V+
N V- (common)
I Signal/Pulse input
R Reset*
*At supply voltage for 2s (max)
Ì
Ì
Ì
Ì
Ì
Price Each
25+
dc Types
10ips
50ms
1:1
±10%
5V, 12V:80mW24V:160mW
IP66
-40°C to +85°C
Max. count speed
Min pulse time
Pulse/pause time
Voltage tolerance
Power Consumption
Front face protection
Temperature Range
ac Type
10ips
50ms
1:1
-10 +6%
230Vac: 600mW
IP65
-40°C to +85°C
223148
Price Each
Voltage
Order Code
5VDC
12VDC
24VDC
230VAC
233-262
233-274
233-286
233-298
1+
10+
100+
250+
2953
2954
farnell.com
Electromechanical Counters - continued
5 Digit Adding Preset Counters
Panel Mounting
7 Digit Non-Reset - F163-3
Maximum count speed
Minimum input time
Minimum pause time
Power Consumption
Frequency/Ripple Factor
Voltage tolerance
Count Life
ac Types
dc Types
10ips
50ms
50ms
5VA
50/60Hz
±10%
50 million
10ips
50ms
50ms
2W
≤48%
±10%
100 million
223117
Automation
Mftrs. List No.
S1-163.3 12VDC
S1-163.3 24VDC
S1-163.3 110VAC/50HZ
S1-163.3 220VAC/50HZ
Order Code
1+
25+
100+
Power Consumption
Max. count speed
Min. Pulse count
Duty Factor at 25°C
Pulse/pause ratio
Max. reset frequency
Max. reset on-time
Temperature Range
Mftrs. List No.
170-547
170-548
170-558
170-549
ac Types
count(reset)
±10%
+1-% -18%
2.75W(16W)
25Hz
50ms (200ms)
100 (10)%
1:1 (1:10)
1 per 2 secs
(1) Mins
-10°C to +50°C
2.5W(12W)
25Hz
20ms (200ms)
100 (20)%
1:1 (1:5)
1 per sec
(2) mins
-10°C to +50°C
0.886.264=925-500
0.886.290=925-524
0.886.214=925-536
223076
Voltage
Order Code
Manual Reset
24VDC
925-500
240VAC
925-524
Panel Mounting
Ì
Ì
Ì
Ì
Ì
dc Types
count(reset)
24V ±10%
Price Each
6 and 8 Digit Totalising Counters
1+
5+
10+
25+
50+
Manual/Electrical reset
6 and 8-digit indication
Manual or non-reset
Push on crimp/solder connectors supplied
Up to 25Hz count speed
Sealed to IP40
24VDC
925-536
5/6 Digit Presettable - FE514-6, FE319-55
Panel cut out=27 52, H=40, W=56
Fixing centres=31, Depth behind panel=72.5
40
Process Control, Timers & Counters
Supply Voltage
dc types
12V± 10%
Duty Factor at 25°C
Power Consumption
Max. Count Speed
Min. pulse length
Temperature Range
100%
2.5W
25Hz
20ms
-10°C to +50°C
Mftrs. List No.
ac Types
115V±10%
240V +10% -18%
100%
2.75VA
10Hz
50ms
-10°C to +50°C
0.864.189=925-858
0.864.190=925-860
H=75, W=60, D=77.5,
Panel cut-out=51 sq.,
Fixing centres=63
0.866.165=925-871
0.868.165=925-901
223078
Price Each
Voltage
Order Code
1+
5+
10+
25+
50+
100+
Ì
Ì
Ì
Ì
Manual 6 digit and electrical presettable 5 digit counters with reset facility
Counters count from zero to the preset figure
SPDT contacts (2A @ 240Vac)
Push-on solder connectors supplied
The following accessories are available:
Wiring socket: The socket plugs onto the rear of the counter, and is suitable for both
manual and electrical/manual types. Rear connections are suitable for soldering or 2.8
0.8mm push-on connectors.
Transparent cover: A dust and splashproof cover with transparent window, allowing operation of pushbuttons. The cover consists of a metal frame, gasket, flexible transparent
window and fixing hardware and gives protection to IP55
6 Digit - Manual Reset
240VAC
925-860
6 Digits - Non reset
24VDC
925-871
8 digit - Non-reset
24VDC
925-901
Manual Reset Types
Max count speed
Power
Min. pulse length
Min. pause between pulses
Duty cycle @ 25°C
Voltage tolerance
6 Digit Reset - F514-65
Ì
Ì
Ì
Ì
Ì
Maximum count speed
Minimum input line
Minimum pause time
Power Consumption
Frequency/Ripple Factor
Voltage tolerance
Count Life
Front panel mounting
Case meets DIN40050 IP41 specification
Front panel push button reset
4.5mm high, 6 digit indication
Push-on crimp/solder connectors supplied
Electrical/Manual Reset Types
H=37.4, W=60, D=77.5
Panel cut-out H=25.8, W=51 Fixing centres=31
ac Types
dc Types
10ips
20ips
50ms
25ms
50ms
25ms
4VA
3W
50Hz
≤48%
±10%
±10%
100 million
50 million
Max count speed
Power
Min. pulse length
Min. pause between pulses
Duty cycle @ 25°C
Voltage tolerance
Price Each
Voltage
Mftrs. List No.
Order Code
24VDC
110VAC
220/240Vac
F514.650AA3B
F514.650AA8B
F514.650AA9B
103-834
103-858
103-860
1+
10+
24V dc
20 ips
2.2W
25ms
25ms
100%
±10%
24V dc
Count Coil
20 ips
4W
25ms
25ms
100%
±10%
110V ac, 220/240V ac
10 ips
2.4VA
50ms
50ms
100%
±10%
Reset Coil
—
22W
250ms
9 reset pulse
*10%
±10%
110V ac, 220/240V ac
Count Coil
10 ips
5VA
50ms
50ms
100%
±10%
Reset Coil
—
25VA
250ms
9 reset pulse
*10%
±10%
*Note: Power should not be applied to reset coil for more than 1 minute.
223118
2954
Panel cut-out=52x52
H=75, W=60
Fixing centres=63
Depth behind panel=72.5
Supply Voltage
Price Each
12VDC
24VDC
110V ac
220/240Vac
Preset value continuously visible
Manual or electric reset
5-digit indication
Sealed to IP40
Push-on crimp/solder connectors supplied
Up to 25Hz count speed
Changeover output contacts 100VA
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Ì 7-digit counter with matt black plastic moulding
cover mounted on a metal base plate
Ì Counter meets environmental specification
Ì DIN40050 IP51
Ì Fitted with an anti-shock device to prevent miscounting due to severe vibration
Ì No rectifier on ac types for immunity to inverse
voltage spikes when used with solenoids etc.
Ì 4mm high digits
Ì Connection via flying leads 300mm long
H=25, W=50, D=67
Base plate H=57, W=48
Fixing centres=47.2 and 30.5
Voltage
element14.com
25+
To preset the counter, depress the reset button and key in the desired figure. Release the button. The preset buttons are then locked which prevents accidental alteration of the preset figure. No counting pulses
can be received while the counter is being reset. Reset of the manual unit is achieved by pressing the reset button, reset of the electrical/manual unit is operated by an external pulse
Mftrs. List No:
FE514.650AB3C
FE319.550AA3B
FE319.550AA9B
025.01.047
FE514.650AB8C
=
=
=
=
=
103-937
177-488
170-556
186-650
103-949
FE319.550AA8B
025.03.050
FE514.650AB9C
Z100.02A
=
=
=
=
177-489
177-492
103-974
170-559
223120
farnell.com
Price Each
Voltage
Order Code
Manual Reset Counters — 6 digit
24VDC
103-937
110V ac
220/240V ac
103-949
103-974
1+
5+
Count rates
10+
24VDC
110V ac
220/240V ac
Calibrator
Displays (LED)
Outputs, solid state
Outputs, relay
Hold time
Operating temperature
177-488
177-489
170-556
223166
Mftrs.
170-559
Price Each
Mftrs. List No.
FE319.550AA3B
FE319.550AA9B
Supply Voltage
VDC24
1+
5+
10+
25+
177-488
170-556
731-924
single preset 8 digit
731-948
V45450E3
10+
Display
Input Ranges
Reflective or dual colour backlit 8 digit LCD display
Input A - DIP switch selectable to accept pulses from a variety of sources, Vmax
= 28 V dc
Input B - Logic signals only or current sinking
User Input
Programmable input, Vmax = 28 V dc, response time
Rate Display
6 digit display, max. Frequency 0.01Hz to 20 kHz,
Count Display
Max. frequency 20 kHz for all count options without setpoint option
Optional Cards
Relay Output: Single FORM-C relay 1A @ 30V dc resistive; 0.3A @ 125V ac
Serial communication: RS485 multipoint balanced RS232 half duplex
Baud rate from 300 to 19200 baud
Programming
Programmable with two front buttons or with software
Operating Temperature -35 to 75°C
Power Supply
9 - 28VDC, 125mA Max. or 85 to 250VAC, 50/60Hz with addtional power supply
module MLPS
Dimensions (WxHxD) 74.9x39.1x43.4mm
Mftrs.
Supply voltage
Display
Count frequency
Operating temperature
3 Count
12-48V dc (nom), 9V dc (min),
60V dc (max)
6 digit LCD, 5mm height
500Hz (max)
-30°C to +65°C
223161
Price Each
Type
Mftrs. List No.
List No.
Order Code
LCD Display
Standard LCD Display - 28VDC
CUB5R000
125-3410●
Red/Green Backlit LCD Display - 28VDC
CUB5B000
125-3411●
Accessories
Optional Relay Output Card
Optional RS485 Serial Communication Card
Optional RS232 Serial Communication Card
Power Supply, 85-250V ac
CUB5RLY0
CUB5COM1
CUB5COM2
MLPS1000
125-3412●
125-3413●
125-3415●
125-3417●
1+
5+
Four levels of programme security
Relay (SPCO) and open collector outputs
Reset to zero or preset number
Accessory sensor power supply
Universal 90-264V ac power requirements
Ì IP65 sealed front panel
Ì Designed to comply with EN50081 and
EN50082 EMC specifications
Ì
Ì
Ì
Ì
Ì
10+
40
Ì Main counter with two presets
Ì 8-digit totalizer
Ì Positive and negative counting range for
main counter and totalizer
Ì Batch counter w/o preset
Ì Start value can be programmed
Ì Scaling factor can be programmed
0,0001 - 9999,99
Ì Preselection mode can be programmed
as progressive preselection or trailing preselection
Display:
4 (or 8) Digit LED Display
Full featured dual LED display counters providing simultaneous count and preset information. Both relay
and open collector outputs
are provided for easy connection to external controlled equipment. Full
configuration of the counter is made via the
front panel.
Three models offer single preset or dual preset count capability, or a single preset counter with a presettable batch counter. The
batch counter can be configured as an 8 digit
single preset up counter.
5+
Series NE216
10+
Single and Dual Preset, One Preset
+ Batch - 4545 Series
1+
Electronic LED-preselection counter with two presets
Price Each
Description
Order Code
Electrical reset only
210-1E073-001A (K01) 12/48VDC 516-260
Manual and electrical reset 210-1M073-001A (K01) 12/48VDC 516-272
Signal inputs:
Input counting rate.:
Control inputs
Signal outputs
Sensor supply
Data storage
Front dimensions:
Ambient temp:
Protection:
Mounting
7 Segment LED -display
5-digit display of real value, 7.6mm high
Decimal point can be programmed
Suppression of leading zero
Comparator inputs
PNP-, NPN-, or AC-Logic,
Voltage level 4...40 V
Can be programmed to 3 Hz, 25 Hz, 10 KHz
2 control inputs for Reset, Stop, Hold.Keylock etc.
2 floating relays to be programmed as
normally open or normally closed contact (260VAC / 1A / 150VA)
12…26 VDC / 60 mA
>10 years via EEPROM
DIN-housing 48 x 48mm
0°C…+50°C
Front IP65 to DIN 40050
Front installation
Process Control, Timers & Counters
443277
H = 24, W = 48, D = 25mm
(overall)
Panel cut-out = 22.2 x 45mm
Connections:
1 Supply +ve (common)
2 Reset 4 Supply -ve
Ì Pulse counter housed in 24x48mm DIN case sealed to
IP65 with fingerproof protected terminals to IP20
Ì Electrical reset and electrical/manual reset versions
Ì Supply voltage connection permits permanent display
if required
Ì separate input connection for monitored supply
Ì Non-volatile memory allows data retention for 25
years
Ì Wide temperature range, low power consumption and
high shock resistance
Automation
LCD, reflective or green/red backlighting
0.46" (11.7mm) high digits
Optional relay and serial output moudle
Count speeds up to 20 kHz
Programmable scaling for count and rate
Bi-directional countingm up/down control
or quadrature sensing
Ì NEMA4X/IP65 sealed front bezel
Ì Dual 4-digit LED displays for count and
preset values
Ì 10kHz count speed
Ì Add/subtract or bidirectional count inputs
Ì Digital calibrator and programmable decimal point
Ì Accepts current sinking or sourcing devices
Ì Key reset, remote reset and auto reset
modes
5+
Type 210
Ì
Ì
Ì
Ì
Ì
Ì
Panel cut-out=45x45
1+
6 Digit Totaliser
8 Digit Dual Counter and Rate Indicator
H=48, W=48, D=110 (behind panel)
Order Code
Single preset
V45450E1
One preset + 1 batch preset or
Electronic Counters
Supply voltage
Accessory power
Counter operation
Price Each
List No.
Accessories
Transparent cover
2955
High speed DC to 10kHz (5kHz for quadrature)
Medium speed DC to 200Hz
Low speed DC to 20kHz
0.001 to 9.999 common to inputs A and B
Upper : 4 digit, 10mm high, Lower : 4 digit, 7mm high
Open collector, 30V dc 100mA max,
SPCO, 5A @ 110V ac, 3A @ 240V ac (res.)
Either output may be latched or momentary, duration from
0.01 to 99.99 secs.
0°C to +55°C
25+
Electrical/Manual Reset Counters — 5 digit
element14.com
246860
Supply
Price Each
Voltage Range
Mftrs List No
Order Code
115 to 230VAC
12 to 30VDC
NE216.012AX01
NE216.013AX01
329-0712
329-0724
1+
10+
TROUBLESHOOTING TIPS
Chat online to one of our
technical engineers at farnell.com
90 to 264V ac 50/60Hz
12V dc ± 25% @ 100mA (+V)
731-924 : 1 Preset, 731-936 : 2 Preset,
731-948 : 1 Preset + 1 Batch Preset + 8 digit
Single preset mode
2955
2956
farnell.com
Electronic Counters - continued
element14.com
High Performance - H7AN
4 Digit LED Display - 72 DIN
Electronic preselection counter with two presets
Series NE134
H=72, W=72, D=115 (behind bezel)
Panel cut-out=68sq.
Ì
Ì
Ì
Ì
Ì
Ì
Ì
Main counter with 1 or 2 presets
8-digit totalizer
Positive and negative counting range for main counter and totalizer
Batch counter with or w/out preset
Start value can be programmed
Scaling factor can be programmed - 0,0001 - 9999,99
Preselection mode can be programmed as progressive preselection or trailing preselection
Display
Automation
LCD-display with two rows of digits and
background illuminations
6-digit display of real value,7mm high
6-digit display of set value, 4 mm high
Comparator inputs
PNP-, NPN-, or AC-Logic, NAMUR
Voltage level 4…40 V
3 control inputs for Reset, Stop, Hold, Keylock etc.
2 floating relays to be programmed as NO or NC contact
(260 VAC / 1A / 150 VA)
12…26 VDC / 60 mA
>10 years via EEPROM
DIN-housing48 x 48mm
0°C…+50°C
Front IP65 to DIN 40050
Front installation
Signal inputs
Control inputs
Signal outputs
Sensor supply
Data storage
Front dimensions
Ambient temp.
Protection
Mounting
Supply voltage
Operation mode
Maximum count
Count and reset inputs
Max. count speed
Control output
100-240VAC, 50/60Hz
Counts up to preset or down to zero (selectable)
9999
Contact or solid state +5V to +30V
Contact: input 30 cps. Solid-state: input 5K cps
Contact: 250V ac, 3A resistive
Solid state: open collector 30Vdc max, 100mA max
Power supply for externally
connected components
Operating temperature range
12V dc ±10%, 80mA (permissable ripple factor 5% max)
-10°C to +55°C
Mftrs. List No. H7AN-4DM
223124
Price Each
Order Code
1+
Process Control, Timers & Counters
24-48VAC
115-230VAC
12-30VDC
Mftrs. List No.
Order Code
NE134.011AX01
NE134.012AX01
NE134.013AX01
329-0621
329-0633
329-0645
25+
50+
Digital Counter - Timer
1/16 DIN - CT500
Ì
Ì
Ì
Ì
Ì
Ì
1+
10+
Dual 4-Digit LED display
5 Programmable timing modes
6 Time ranges from 0.01 sec. to 9999 hrs.
Counter range from -999 to +9999
2 Independent relay outputs rated at 5A / 230V ac
CE and CSA Approved, UL Recognised
H = 48, W = 48, D = 102mm
538744
4 and 6 Digit LCD Display - LC4H
Supply
Mftrs.
Price Each
Voltage
List No.
Order Code
24V ac/dc
90V to 270V ac
CT500ML
CT500MH
173-4634●
173-4636●
1+
Multifunction Counter
1/16 DIN - tico 732
5 input modes and 7 output modes
Ì Water and dust resistant to IP66
Bright 2 colour backlit LCD display
Ì Relay and solid state (transistor)
Seesaw buttons for easy operating (4 digit type)
output versions available
Present and preset values displayed
Ì UL Recognised and CSA apScrew (flush mounting) and 11-pin (surface
proved
mounting) connection styles available
Count range
Count speed
Contacts
Operating voltage
Operating temperature
Up, down, directive, independent or phase difference
Maintain output/held count, maintain output/over count I,
maintain output/over count II, one shot/over count,
one shot / recount I, one shot / recount II, one shot / hold count
-999 to 9999 (4 digit), -99999 to 999999 (6 digit)
30Hz, 5kHz (selectable)
3A, 250Vac (relay), 100mA, 30Vdc (transistor)
100 to 240Vac (ac type), 12 to 24Vdc (dc type)
-10°C to +55°C
223085
Connection Mftrs.
Voltage
Type
Part No.
Price Each
Order Code
Relay Output — 4 digit
12V to 24V dc
Screw
LC4H-R4-DC24VS
185-073
100V to 240Vac
100V to 240Vac
Screw
11 Pin
LC4H-R4-AC240VS
LC4H-R4-AC240V
185-097
185-103
Relay Output — 6 digit
12V to 24V dc
Screw
100 to 240Vac
Screw
LC4H-R6-DC24VS
LC4H-R6-AC240VS
185-152
185-176
1+
High-contrast LCD Display, 6 digits
Small and compact DIN dimensions 48 x 48 mm
Easy operation by one key per digit
Direct access to parameters
Available with 1 or 2 presets
Transistor and relay with changeover contact, for
each preset
Ì Integrated separate totalizer
Ì 5 basic functions easily programmable: counter,
tachometer, time counter, shift counter and batch
counter
Ì Display range from -99999 to 999999
Ì
Ì
Ì
Ì
Ì
Ì
H = 48, W = 48, D = 64.5 (screw), 70.1 (11-pin)
Ì
Ì
Ì
Ì
Ì
Operating modes
Input
Output
2956
10+
Electronic Timer/Counter
Price Each
Voltage
5+
170-561
246870
40
Ì Panel mounting DIN72 high speed electronic counter for batch or positional
control with 4-digit LED display
Ì Sensor input is either relay contact or
solid-state signal
Ì Reset is either external, manual or selfreset
Ì Battery backup retains count in case of
supply failure
Ì Counter has built-in selector switches for
programming functions such as maximum counting speed, UP or DOWN display, manual reset
Ì Connection by screw terminals
Ì UL Recognised and CSA approved
5+
10+
The Tico 732 series of multi-function counters from Hengstler are provided with extended
functions that increase their versatility and further enhance the range of possible applications.
Tico 732 models are available with LCD displays and in different versions dependent on
the supply voltage and number of outputs required.
The multi-functionality of Tico 732 is due to the fact they can be programmed as an impulse or preset counter, time meters with or without presets, as a tachometer with or without limit values, or as a shift or batch counter.
For each mode of operation there are programmable parameters which are customised according to the specific tasks.
Pulse level: the new TTL input allows the use of a much wider range of pulse generators
including RS422 line drivers.
Time Counter: now stops when the preset value has been reached.
Shift counter: now available with preset values to provide two separate preset counters in
one housing. In addition, the total value (sum) of both counters is recorded and displayed.
Batch counter: Toggles between batch counter mode and totalising counter mode; the totalising counter mode records the total (sum) value.
Hengstler Tico 732 Counters come in a compact housing, DIN size 48 x 48mm, and are
designed for easy programming via a user-convenient keyboard, easy installation by
means of a clamp-on fitting and easy connection via screw type fasteners.
621952
farnell.com
Supply
Output
Voltage
Relays List No.
Mftrs.
Price Each
Order Code
LCD Display
12V DC to 24V DC
1
0.732.002
766-926
12V DC to 24V DC
2
0.732.012
766-951
1+
5+
Mftrs.
10+
LCD Display
Ì Large 8.6mm character height
Ì Backlit models available for improved visibility in dimly
lit environments
Ì Black and light grey cases available
Ì Key protect switch prevents accidental reset
Ì Low panel depth 48.5mm
Ì Variety of input options
Ì 7 digits, time range 0 to 3,999d 29.9h
Ì Dual time range 999,999h to 3,999h23.9d or 999h
59m59 to 9,999h 59.9m
Ì Self-powered by built in battery, backlit models required
24V dc power supply
Ì UL Recognised CSA and VDE approved
H = 24, W = 48, D = 48.5
Backlight type
Without Backlight
PNP/NPN
Count input
Multivoltage
24V dc
Not required (internal battery)
High 4.5 to 30V dc
Low 0 to 2V dc
Operating temperature
Order Code
0.731.101
0.731.301
0.731.501
0.731.506
0.731.502
925-720
925-731
925-755
925-767
925-810
1+
5+
10+
25+
List No.
Order Code
H7EC-NV-BH
326-2730
Counters - Black Case
30Hz to 1kHz
NPN/PNP
20Hz
Non-voltage
H7EC-NV-B
H7EC-N-B
326-2753
326-2790
Counters - Grey Case - With Backlight
30Hz to 1kHz
NPN/PNP
H7EC-NV-H
326-2741
H7EC-NV
H7EC-NFV
H7EC-N
326-2765
326-2789
326-2807
Time Counters - Black Case
Hours/mins/sec
NPN/PNP
Hours/mins/sec
Non-voltage
H7ET-NV1-B
H7ET-N1-B
326-2911
326-2959
Time Counter - Grey Case
Hours/Days
Non-voltage
H7ET-N
326-2881
5+
10+
SPDT
DPDT
Order Code
1+
5+
+
2CSM258763R0621 210-2355●
2CSM256313R0621 210-2356●
Electronic Indicators
Universal Intelligent Panel Meter
Transfer Function Module Library
H = 48, W = 96, D = 140mm
D (Behind panel) = 131,
Cutout = 45 X 92mm
The DM3600 is an intelligent digital
panel meter that can accept inputs
from a wide variety of sensors and
display the signal digitally.
The DM3600 is available in two versions, AC supply or DC supply. All
functions are programmable via the integral front panel keys.
The DM3600 supports TFML (Transfer
5
WARRANTY
YEARS
Function Module Library) i.e. the ability to download custom functionality by means of standard modules available from the manufacturers web
site. This allows pre-written or custom control functions to be quickly and easily incorporated.
Ì Internal Power Supply for Loop Exitation
Ì Universal Input
Ì Custom Software For Your Application Option (TFML)
Ì 6 Digit Display
Ì IP65 Sealed Front Ì Programmable Via The Front Panel Or Remote PC
Ì User Non Linear Function For Tank Level Applications
Counter/Timer/Tacho/Position
Indicator - TICO 731
LED or LCD
535022
Counters with 8-digit LCD/6 digit LED displays
Bi-directional position indicator with 6-digit LED display
Time counters with 8-digit LCD displays
Tachometers with 8-digit LCD and 6-digit LED display
Display only unit for PLC serial communication, 8-digit
LCD display
Ì Bezel sealed to IP65
Ì Reset can be manual via keypad or external, and can be
locked
Ì
Ì
Ì
Ì
Ì
Bezel=24x48, Panel CutOut=22x45
Function
Counter
Counter (high voltage input)
Counter
Position Indicator
Tacho
Contact Configuration List No.
Display
LCD
LCD
LED
LED
LED
Supply
Internal Lithium Battery
Internal Lithium Battery
12-24v dc
12-24v dc
12-24v dc
Mftrs. List No.
0.731.101
0.731.301
0.731.501
0.731.506
0.731.502
Order Code
925-720
925-731
925-755
925-767
925-810
Supply
Voltage
90 - 264V ac
20 - 35V dc
Mftrs.
Price Each
List No.
Order Code
DM3600U/S1
DM3600U/S2
170-6804●
170-6805●
1+
INTELLIGENT ONLINE BUYING
SYSTEM PROVIDING
Complete cost control, reduced
administration time, visibility of your
spend, flexibility and personalised to
your company’s needs.
farnell.com/ibuy
40
Process Control, Timers & Counters
Counters - Grey Case
30Hz to 1kHz
NPN/PNP
20Hz
Multi-voltage
20Hz
Non-voltage
1+
Price Each
Automation
223102
Input
230VAC
PushbuttonVAC
659464
Price Each
Counters - Black Case - With Backlight
30Hz to 1kHz
NPN/PNP
A range of digital time switches with an exclusive design, featuring a backlit white
LCD display, plus extremely simple use
with two-line text menus and only four pushbuttons, make the D
Line products ideal for automating the functions of the installation.Thanks to the pioneering way in which vacation periods can
be managed, the new D Line allows you to override the normal
weekly program for one or more periods of the year or even
through different years. The range includes versions with 1 and
2 channels, equipped with large capacity internal batteries so
they are able to function during a blackout and an EEPROM permanent data store, to ensure that the scheduled program is followed and the date and hour settings are maintained even during
a power failure.
Mftrs.
Mftrs.
Operating temperature
Storage temperature
Electrical connection
Price Each
List No.
D Line
Input voltage
Timing Adjustment
High 24 to 240V ac/dc
Low 0 to 2.4V ac/dc
Short circuit impedance 10K Ω max.
Open impedance 750K Ω min.
-10°C to +55°C
Non-voltage
Counting Frequency
Counter LCD
Counter LCD
Counter LED
Position Indicator/LED
Tacho LED
2957
Digital Time Switches
Supply voltage
Mounting
Depth behind the panel
Pulse shape
Min. pulse length
Display
Nominal data retention
Amplitude thresholds
Supply Voltage Function/Display
Lithium Battery
Lithium Battery
12-24V dc
12-24V dc
12-24V dc
Time Counters
Range
element14.com
With clamping frame
60mm (32mm 0.731.101)
Any square wave 1:1 (for max frequency)
25ms (20Hz), 17ms (30Hz), 70s (7.5kHz)
8-digit LCD, 7mm or 6-digit LED, 7mm
Lithium battery version = 7 years, 12-24V versions >10 years
<0.7V and >5V, max. 40V ac/dc (standard modes)
<3V and >12V, max. 250V ac/dc (high input version)
max. 7.5kHz (30Hz for contact input) standard modes
max. 20kHz high input version only
0°C to +50°C
-20°C to +60°C
Screw terminals
663086
2957
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement