BradCommunications DRL- 111, 241, 250, 280, 281, 290 Industrial Ethernet Switch Hardware Reference Guide
Below you will find brief information for Industrial Ethernet Switch DRL-111, Industrial Ethernet Switch DRL-241, Industrial Ethernet Switch DRL-250, Industrial Ethernet Switch DRL-280, Industrial Ethernet Switch DRL-281, Industrial Ethernet Switch DRL-290. These switches are designed to provide high-speed, reliable communication between Ethernet devices in an industrial environment. They feature automatic speed and duplex detection, allowing for seamless integration with both standard and fast Ethernet devices. The switches also support automatic learning, aging, and migration of MAC addresses, ensuring efficient network management.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Hardware Reference Guide
Document Edition: 1.0
Document #: 715-0089
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Document Edition: 1.0
Date: November 22, 2006
This document applies to the following Ethernet switch products: DRL-111, DRL-241,
DRL-250, DRL-280, DRL-281 and DRL-290.
Copyright ©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
This document and its contents are the proprietary and confidential property of Woodhead
Industries Inc. and/or its subsidiaries and may not be used or disclosed to others without the express prior written consent of Woodhead Industries Inc. and/or its subsidiaries.
SST and Direct-Link are trademarks of Woodhead Industries. All other trade names are trademarks or registered trademarks of their respective companies.
At Woodhead, we strive to ensure accuracy in our documentation. However, due to rapidly evolving products, software or hardware changes occasionally may not be reflected in our documents. If you notice any inaccuracies, please contact us (see Appendix C of this document).
Written and designed at Woodhead Software & Electronics, 50 Northland Road,
Waterloo, Ontario, Canada N2V 1N3.
Hardcopies are not controlled. ii
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Preface
Preface Sections:
•
Purpose of this Guide
•
Conventions
Preface
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
iii
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Purpose of this Guide
This manual explains how to install and maintain the Direct-Link Industrial Ethernet Switches and Fiber Converter.
Conventions
This guide uses special notation to help enhance your understanding.
Special Notation
The following special notations are used throughout this guide:
Warning
Warning messages alert the reader to situations where personal injury may result. Warnings are accompanied by the symbol shown, and precede the topic to which they refer.
Caution
Caution messages alert the reader to situations where equipment damage may result. Cautions are accompanied by the symbol shown, and precede the topic to which they refer.
Note
A note provides additional information, emphasizes a point, or gives a tip for easier operation. Notes are accompanied by the symbol shown, and follow the text to which they refer. iv Preface
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Contents
Preface .......................................................................................................................... iii
Purpose of this Guide ................................................................................................................. iv
Conventions................................................................................................................................ iv
Special Notation ...................................................................................................................... iv
General Information ...................................................................................................... 7
1.1 Overview ................................................................................................................................8
1.2 Part Numbering Convention...................................................................................................8
1.3 Operation ................................................................................................................................9
1.4 Performance Specifications ....................................................................................................9
LED Indicators............................................................................................................. 11
2.1 Overview ..............................................................................................................................12
2.2 Power LED ...........................................................................................................................15
2.3 ACT / LNK LEDs ................................................................................................................15
2.4 10 / 100 LEDs.......................................................................................................................16
Installation ................................................................................................................... 17
3.1 Overview ..............................................................................................................................18
3.2 Procedure..............................................................................................................................19
Power Wiring ............................................................................................................... 23
4.1 Overview ..............................................................................................................................24
Contents
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
v
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Ethernet Wiring ........................................................................................................... 25
5.1 Overview ..............................................................................................................................26
5.2 RJ45 Ethernet Wiring ...........................................................................................................27
5.3 Ethernet Cable Pin-outs........................................................................................................28
5.4 Ethernet Connector Pin Positions.........................................................................................28
5.5 Ethernet Connector Pin-outs.................................................................................................28
5.6 Cable Distance......................................................................................................................29
5.7 Ethernet Fiber Wiring Guidelines.........................................................................................29
5.8 Full or Half Duplex Operation .............................................................................................30
Switch Features........................................................................................................... 31
6.1 Switch Features ....................................................................................................................32
Technical Specifications ............................................................................................ 35
A.1 Technical Specifications......................................................................................................36
Standards and Safety.................................................................................................. 41
B.1 Standards and Safety............................................................................................................42
B.1.1 CE Statement .................................................................................................................42
B.1.2 FCC Statement...............................................................................................................42
B.1.3 General Warnings ..........................................................................................................43
Warranty and Support................................................................................................. 45
C.1 Warranty ..............................................................................................................................46
C.2 Technical Support ................................................................................................................46
C.2.1 Getting Help ..................................................................................................................46 vi Contents
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
1
General Information
Chapter Sections:
•
Overview
•
Part Numbering Convention
•
Operation
•
Performance Specifications
General Information
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
7
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
1.1 Overview
The Direct-Link Industrial Ethernet Switches and Fiber Converter are easy to install and operate because little or no user configuration is required. Once the Ethernet connections are made and the unit is powered up, it will immediately begin to operate.
Note
The Fiber Converter incorporates the same Layer 2 Ethernet switch technology as all the other DRL-2xx products. Throughout this manual, any mention of Ethernet Switches also applies to the Fiber Converter, unless otherwise stated.
1.2 Part Numbering Convention
Each switch’s name indicates the product brand, whether the switch is unmanaged or managed, the number of RJ ports, the number of fiber ports and the connector type.
Figure 1: Part Numbering Convention
Family Designator
1 = Media Converter
2 = Unmanaged
3 = Managed
4 = Ring/Redundant
5 = Reserved
6 = Reserved
7 = Modular
8 = Harsh Switch, Unmanaged
9 = Harsh Switch, Managed
Number of standard ports
(RJ 45 or M12 4 pole)
Number of Fiber Ports
DRL-XXX-XXX
Fiber Media Designator
(Note: only used when a fiber port is indicated in preceding digit)
M = Multi Mode
S = Single Mode
Fiber Connector Designator
SC = SC connector
ST = ST connector
LC = LC connector
RJ = MTRJ connector
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
1.3 Operation
Unlike an Ethernet hub, which broadcasts all messages out all ports, the Industrial Ethernet
Switches route Ethernet messages via only the appropriate port. The major benefits of this are increased bandwidth and speed, reduction or elimination of message collisions, and deterministic performance when tied with real-time systems.
The Direct-Link Industrial Ethernet Switches support both 10BaseT (10 Mbps) and 100BaseTx
(100 Mbps) on their RJ45 ports. Each of these ports independently auto-senses the speed, allowing you to interface to regular or fast Ethernet devices. Some models also have 100BaseFX
(100 Mbps) fiber optic port(s).
Refer to Section 6 for more information on Industrial Ethernet Switch operation and features.
1.4 Performance Specifications
The performance specifications are as follows. For complete technical specifications, including
switch dimensions, refer to Appendix A .
Table 1: Performance Specifications
Ethernet Switch Type
Ports (models vary)
Required Voltage
Ethernet Standards
Ethernet Protocols
Speed Per Port
Ethernet Isolation
Operating Temp.
Humidity
Unmanaged
10/100BaseT(x) (Shielded RJ45), 100BaseFX (SC or ST connectors)
10 - 30 VDC (see Appendix A for power consumption for each model)
IEEE 802.3 (10BaseT), 802.3u (100BaseTX), 802.3x (Full Duplex)
All standard IEEE 802.3 protocols supported
RJ45: 10 Mbps/100 Mbps
Fiber: 100 Mbps (full duplex)
1500 Volts RMS (for 1 minute)
0 to 60 °C
5 to 95% (non-condensing)
General Information
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
9
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
10 Information
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
2
LED Indicators
Chapter Sections:
•
Overview
•
Power LED
•
ACT / LNK LEDs
•
10 / 100 LEDs
LED Indicators
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
11
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
2.1 Overview
The Direct-Link Industrial Ethernet Switches all have a power LED and communication LEDs for each port. Refer to the pictures below for the typical location of these LEDs. The exact location of these LEDs may vary between the different models.
Figure 2: LEDs on DRL-111 Figure 3: LEDS on DRL-241
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Figure 4: LEDs on DRL-250 Figure 5: LEDs on DRL-280
LED Indicators
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
13
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Figure 6: LEDs on DRL-281 Figure 7: LEDs on DRL-290
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
2.2 Power LED
This LED will be on solid when proper power has been applied to the unit.
2.3 ACT / LNK LEDs
The activity (ACT) and link (LNK) functionality is combined into one LED. There is one of these LEDs per port. For switches with a fiber port, the Activity LED is located adjacent to the
Power LED. On such switches, the Activity LED behaves the same as the other Activity LEDs described in the table below.
Note
The Activity LED is only present on switches that have a fiber port.
Table 2: ACT / LNK LEDs
LED State
Off
On Solid (not flashing)
Flashing
Meaning
There is not a proper Ethernet connection (link) between the port and another Ethernet device. Make sure the proper cable type is in use and that it has been plugged securely into the ports at both ends.
For Ethernet wiring directions, refer to Chapter 5,
There is a proper Ethernet link between the port and another Ethernet device, but no communications activity is detected.
There is a proper Ethernet link between the port and another Ethernet device, and there is communications activity.
LED Indicators
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
15
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
2.4 10 / 100 LEDs
These LEDs indicate the communications speed detected on the port. There is one of these LEDs per RJ45 port.
Note
The fiber optic port does not have a 10 / 100 LED because its speed is fixed at 100 Mbps.
Table 3: 10 / 100 LEDs
LED State
Off
On
Meaning
A 10 Mbps (10BaseT) connection is detected.
A 100 Mbps (100BaseTx) connection is detected.
Note
On the DRL-280, DRL-281 and 290, the ACT/LNK and 10/100 LEDs are combined into a single bicolor LED. It behaves as described in Table
2, but the speed is indicated by a yellow state for 10mbps, and a green state for 100mbps.
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
3
Installation
Chapter Contents:
•
Overview
•
Procedure
Installation
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
17
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
3.1 Overview
The Direct-Link Industrial Ethernet Switches can be snapped onto a standard DIN rail
(EN50022) or screwed directly to a flat panel. Refer to the photos below.
Note
•
The Ethernet connections for all models are located on the face of the unit. The power connections for all models are located at the top.
•
Make sure you allow enough room to route your Ethernet cables.
Warning
Install the Direct-Link Industrial Ethernet Switch in accordance with local and national electrical codes.
18 Installation
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
3.2 Procedure
The Industrial Ethernet Switches are designed to snap tightly to a standard 35mm DIN rail. This is done by first moving the tabs to an Open position, placing the switch against the rail and then moving the tabs to a Closed position. Refer to Figures 8 and 9 for views of the tabs in the Open and Closed positions.
Figure 8: Switch in Open Position
Installation
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
19
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Figure 9: Switch in Closed Position
If the switch is to be mounted using the screw mount, make sure the tabs are in a Closed position, see Figure 9. A #8-32 pan head sheet metal screw is recommended for attaching the switch to the flat panel.
20 Installation
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Figure 10: Screw Mount Position
Installation
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
21
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
22 Installation
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
4
Power Wiring
Chapter Contents:
•
Overview
Power Wiring
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
23
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
4.1 Overview
The switches can be powered from the same DC source that is used to power your I/O devices. 10 to 30 VDC needs to be applied between the P1 terminal and the Common terminal (Figure 11).
The chassis ground terminal should be tied to the panel on chassis ground. To reduce downtime resulting from power loss, the switch can be powered redundantly with a second power supply.
Figure 11: Wiring for Unmanaged Switch
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
5
Ethernet Wiring
Chapter Contents:
•
Overview
•
RJ45 Ethernet Wiring
•
Ethernet Cable Pin-outs
•
Ethernet Connector Pin Positions
•
Ethernet Connector Pinouts
•
Cable Distance
•
Ethernet Fiber Wiring Guidelines
•
Full or Half Duplex Operation
Ethernet Wiring
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
25
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
5.1 Overview
These switches provide connections to Ethernet devices on the factory floor. Typically, the uplink port or fiber port is used to connect to another Ethernet switch or hub, which is connected to the main Ethernet backbone. The other Ethernet ports are then connected to Ethernet devices such as PLCs, Ethernet I/O, or industrial computers. For increased reliability, electrical isolation is provided on the Ethernet ports.
Note
Follow normal Ethernet wiring practices when installing the Direct-Link
Industrial Ethernet Switch and Fiber Converter.
The following figure illustrates the typical switch installation.
Figure 12: Typical Switch Installation
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
5.2 RJ45 Ethernet Wiring
Use data-quality (not voice-quality) twisted pair cable rated category 5, with standard RJ45 connectors. For best performance, use shielded cable.
Note
These cables are available as straight-thru or cross-over configurations.
All Direct-Link Industrial Ethernet switches have auto-mdi/mdi-x (auto-crossover) ports that will work with either cable type.
Ethernet Wiring
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
27
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
5.3 Ethernet Cable Pin-outs
Table 4: Straight-thru Cable Wiring
Pin 1
Pin 2
Pin 3
Pin 6
Pin 1
Pin 2
Pin 3
Pin 6
Table 5: Cross-over Cable Wiring
Pin 1
Pin 2
Pin 3
Pin 6
Pin 3
Pin 6
Pin 1
Pin 2
5.4 Ethernet Connector Pin Positions
Figure 13: Ethernet Connector Pin Positions
5.5 Ethernet Connector Pin-outs
Table 6: Ethernet Connector Pinouts
Pin # MDI-X Port
1 TX+
2 TX-
3 RX+
6 RX-
MDI Port
(typical for uplink)
RX+
RX-
TX+
TX-
Auto-MDI / MDI-X Ethernet Device Port
TX/RX+
TX/RX-
RX/TX+
RX/TX-
RX+
RX-
TX+
TX-
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
5.6 Cable Distance
The maximum cable length for 10/100BaseT(x) is typically 100 meters (328 ft.).
Table 7: Cable Distance
From
Switch
Switch or Hub
To
Switch or Hub
PLC, Ethernet I/O, PC, etc.
Maximum Distance
100 meters (328 feet)
100 meters (328 feet)
Note
Hubs and Switches are different devices. Hubs broadcast all messages out all ports. Switches route messages out of the appropriate port only.
5.7 Ethernet Fiber Wiring Guidelines
The DRL-111, DRL-241 and DRL-281 has one multi-mode or single-mode port. The multimode port supports a maximum segment length of 2 km each. The single-mode port supports a maximum segment length of 15 km.
Each fiber optic port on the switch is comprised of a pair of SC or ST connectors. When making your fiber optic connections, make sure that the transmit (TX) port of the switch connects to the receive (RX) port of the other device, and the receive (RX) port of the switch connects to the transmit (TX) port of the other device. See Figure 13 below.
The ACTIVTY LED will be ON solid when you have made a proper connection and will blink to show activity.
Figure 14: 100BaseT Fiber Ports (SC Style)
Ethernet Wiring
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
29
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
5.8 Full or Half Duplex Operation
The RJ45 ports will auto-sense for Full or Half duplex operation. The fiber optic port is fixed at
Full duplex operation.
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
6
Switch Features
Chapter Contents:
•
Switch Features
Switch Features
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
31
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
6.1 Switch Features
Here’s a brief explanation of the features found in the Direct-Link Industrial Ethernet Switches.
10BaseT and 100BaseTx Auto-Detection
Standard Ethernet (10BaseT) has a maximum speed of 10 Mbps. Fast Ethernet (100BaseTx) has a maximum speed of 100 Mbps. The RJ45 ports on the switches automatically select the appropriate speed.
100BaseFX (Multi-mode and Single-mode) Fiber Optic Port
The fiber optic port found on some models is classified as 100BaseFX and supports 100 Mbps operation only. Both multi-mode and single-mode models are available. Multi-mode fiber has a large core diameter relative to a wavelength of light, and is typically 62.5 microns.
Light injected into the fiber travels through many different paths, causing multiple modes to occur at the receiving end. This dispersion of light limits the distance for multi-mode to about
2km. Single-mode fiber has a thin core diameter of typically 10 microns, which eliminates multi-mode dispersion and allows distances of more than 15km.
1K or 2K MAC Addresses with Automatic Learning, Aging and Migration
Each Ethernet device inserts its unique “MAC” address into each message it sends out. The port on the switch used for a given MAC address is automatically learned when a frame is received from that address. Once an address is learned, the switch will route messages to the appropriate port only, instead of broadcasting messages out all ports like a hub. A timestamp is also placed in memory when a new address is learned. This timestamp is used with the aging feature, which will remove unused MAC addresses from the table after 300 seconds. If a device moves, the associated port on the switch will be changed (migrated) as needed. Up to 1,024 MAC addresses can be stored and monitored at any time on the DRL-111, DRL-241 and DRL-250. For the
DRL-280, DRL-281 and DRL-290 this increases to 2, 048 MAC addresses.
Auto-Crossover (Auto-mdi/mdi-x)
The RJ45 ports will automatically detect the cable type (straight-thru vs. cross-wired) and re-configure themselves accordingly.
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Auto-Sensing or Auto-Negotiating Speed
The RJ45 ports will auto-negotiate with the connected device to determine the optimal speed
(10 Mbps vs. 100 Mbps).
Automatic Power Saving
If there is no cable on a port, most of the circuitry for that port is disabled to save power.
Backoff Operation
The switches will drop a packet after 16 collisions.
Back Pressure for Half-Duplex
The switches will apply “back pressure” when necessary with half-duplex operation. This will reduce congestion on busy networks.
Buffering
SRAM is used for buffering the messages. The DRL-111, DRL-241 and DRL-250 has 512 KB.
The DRL-280, DRL-281 and DRL-290 have 1 MB of SRAM for buffering.
Unmanaged Operation
The switches require no supervisory processor to operate properly.
Flow Control
The switches automatically support flow control frames on both the transmit and receive sides.
Switch Features
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
33
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Forwarding
The switches support store and forward mode. They forward messages with known addresses out the appropriate port only. Messages with unknown addresses, broadcast messages, and multicast messages get forwarded out all ports, except the source port. The switches will not forward error packets, 802.3x pause frames, or “local” packets.
Full/half-Duplex Operation
The switches’RJ45 ports support both full and half duplex flow control. The fiber optic port supports full duplex only.
Illegal Frames
Illegal frames, as defined by IEEE 802.3, will be dropped. This includes short frames, long frames and FCS error frames.
IEEE 802.3 Compliant
The switches abide to the IEEE 802.3 standard for 10BaseT, 100BaseTX, and 100BaseFX
Ethernet communications.
Late Collision
If a packet experiences collisions after 512 bit times of transmission, it will be dropped.
Latency
The typical latency of a message is 5 microseconds or faster. The latency is the time it takes a message to be routed internally to a switch from one port to another.
Plug and Play
This means that most of the switches’ functions or features are automatic and that no optional parameters need to be set. Just plug in your Ethernet cables, apply power, and the unit will immediately begin to operate.
Protocol Independent
The switches simultaneously support all popular Ethernet protocols and networks, such as
TCP/IP, the Internet (IP), UD and NetBEUI that run over standard Ethernet (IEEE 802.3).
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
A
Technical Specifications
Appendix Contents:
•
Technical Specifications
Technical Specifications
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
35
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
A.1 Technical Specifications
The hardware technical specifications for the Direct-Link Industrial Ethernet Switches are as follows.
Table 8: 10/100BaseT(x) Ports:
10/100BaseT(x) ports
Protocols supported
Ethernet compliancy
Auto-crossover
(Auto-mdi/mdi-x)
Auto-negotiating
Flow control
Ethernet isolation
Plug and play
Cable requirements
Max. cable distance
Shielded RJ45
All standard IEEE 802.3
IEEE 802.3, 802.3u, 802.3x
Supported on all ports
10BaseT or 100BaseTX
Half or full duplex
1500 VRMS 1 minute
Yes
Twisted pair (Cat. 5) (shielded recommended)
100 meters
Table 9: Fiber Port: (multi-mode)
100BaseFX ports
Fiber port mode
Fiber port connector
Optimal fiber cable
Center wavelength
TX output power
RX input sensitivity
Maximum distance
Half and full duplex
Ethernet compliance
Eye safety
1
Multi-mode
Duplex SC or ST
50/125, 62.5/125 µm
1300 nm
Contact WSE for optical details.
4 km (see web for details)
Full duplex
100BaseFX
IEC 60825-1, Class 1; FDA 21 CFR 1040.10 and 1040.11
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Table 10: Fiber Port: (Single-mode)
100BaseFX ports
Fiber port mode
Fiber port connector
Optimal fiber cable
Center wavelength
TX output power
RX input sensitivity
Maximum distance
Half and full duplex
Ethernet compliance
1
Single-mode
Duplex SC or ST
9/125, 10/125 µm
1300 nm
Contact WSE for optical details.
20 km
Full duplex
100BaseFX
Table 11: General Specifications:
Forwarding mode
Latency (typical)
MAC addresses
Address learning
Address aging
Address migration
Backoff operation
Back pressure
Buffer memory
Store and forward
5 usec (time to route a message from one port to another internally to switch)
1K or 2K
Automatic
Remove old address after 300s
Automatic
Drops after 16 collisions
Automatic for half-duplex
512KB (DRL-111, -241 & -250) or 1MB (DRL-280, -281 & -290)
Buffer size
Illegal frames
Late collisions
Required supply voltage
Power consumption (typical)
128 bytes per buffer (all models)
Dropped per 802.3
Dropped after 512 bit times
10 – 30 VDC
2W (DRL-111); 2.16W (DRL-250); 3.16W (DRL-241);
336W (DRL-280); 4.36W (DRL-281), 4W (DRL-290)
Automatic Power saving
Mounting
Environmental
Operating temperature range
Storage temperature range
Humidity
DIN rail or panel direct
0 to 60 C
-40 to 85 C
5 to 95 % (non-condensing)
Vibration IEC68-2-6
Electrical safety EN61010-1
EMI emissions
EMC immunity
FCC part 15, ICES 003, EN550
11
EN61326
Packaging IP30 protection
Technical Specifications
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
37
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
Figure 15: Unmanaged Switch, Side View
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Figure 16: Unmanaged Switch,
Front View (DRL-280, DRL-281 & DRL-290)
Figure 17: Unmanaged Switch,
Front View (DRL-111, DRL-241 & DRL-250)
Technical Specifications
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
39
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
B
Standards and Safety
Appendix Sections:
•
Standards and Safety
Standards and Safety
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
41
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
B.1 Standards and Safety
The applicable standards and certifications are:
European Directives US Emissions
B.1.1 CE Statement
Electrical safety - EN61010-1 (IEC61010)
EMI emissions - FCC part 15, ICES 003, EN55011; Class A
EMC immunity – EN61326
B.1.2 FCC Statement
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Note
This equipment has been tested and found to comply with the limits for a
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense.
Warning
Changes or modifications not expressly approved by Woodhead
Industries could void the user’s authority to operate the equipment.
42 Standards and Safety
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
B.1.3 General Warnings
Caution
This equipment is neither designed for, nor intended for operation in installations where it is subject to hazardous voltages and hazardous currents.
Note
To maintain compliance with the limits and requirements of the EMC
Directive, it is required to use quality interfacing cables and connectors when connecting to this device.
Note
The supply voltage for this equipment must be delivered as Separated
Extra Low Voltage (SELV).
Standards and Safety
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
43
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
44 Standards and Safety
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
C
Warranty and Support
Appendix Sections:
•
Warranty
•
Technical Support
Warranty and Support
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
45
Hardware Reference Guide Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter
C.1 Warranty
For warranty information pertaining to the switch, refer to http://www.mysst.com/warranty.asp
.
C.2 Technical Support
Please ensure that you have the following information readily available before calling for technical support:
•
Switch type and serial number
•
Details of the problem you are experiencing: switch type and version, target network, and circumstances that may have caused the problem
C.2.1 Getting Help
Technical support is available during regular business hours by telephone, fax or email from any
Woodhead Software & Electronics office, or from http://www.woodhead.com
. Documentation and software updates are also available on the Web site.
North America
Canada:
Tel: 1-519-725-5136
Fax: 1-519-725-1515
Email: [email protected]
Europe
France:
Tel: 33-(0)2-32-96-04-22
Fax: 33-(0)2-32-96-04-21
Email: [email protected]
Germany:
Tel: 49-711-782-374-22
Fax: 49-711-782-374-11
Email: [email protected]
46 Warranty and Support
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
Direct-Link™ Industrial Ethernet Unmanaged Switches and Fiber Converter Hardware Reference Guide
Italy:
Tel: 39-010 595 4052
Fax: 39-010-595 6925
Email: [email protected]
Other countries:
Tel: 33-(0)2-32-96-04-23
Fax: 33-(0)2-32-96-04-21
Email: [email protected]
Asia-Pacific
Japan:
Tel: 81-3-5791-4621
Fax: 81-3-5791-4688
Email: [email protected]
Singapore:
Tel: 65-6261-6533
Fax: 65-6261-3588
Email: [email protected]
China:
Tel: 86-21-5835-9885
Fax: 86-21-5835-9980
Email: [email protected]
For the most current contact details, please visit http://www.woodhead.com/ .
Warranty and Support
©2006 Woodhead Software & Electronics, Division of Woodhead Canada Limited
Document Edition: 1.0, Document #: 715-0089, Template Edition: 1.1, Template #: QMS-06-045
Use, duplication or disclosure of this document or any of the information contained herein is subject to the restrictions on page ii of this document.
47
advertisement
Key Features
- Auto-Sensing or Auto-Negotiating Speed
- Automatic Power Saving
- 100BaseFX (Multi-mode and Single-mode) Fiber Optic Port
- Automatic Power Saving
- 1K or 2K MAC Addresses with Automatic Learning, Aging and Migration
- Auto-Crossover (Auto-mdi/mdi-x)
- Unmanaged Operation
- Flow Control
- Back Pressure for Half-Duplex