FENGER HDLT 1801, 2801, 4802 HD Digital Encoder / Modulator User Guide and Installation Manual

FENGER HDLT 1801, 2801, 4802 HD Digital Encoder / Modulator User Guide and Installation Manual

Below you will find brief information for HD Digital Encoder / Modulator HDLT 1801, HD Digital Encoder / Modulator HDLT 2801, HD Digital Encoder / Modulator HDLT 4802. These devices convert digital video broadcasting (DVB-T) high-definition video and audio signals to COFDM, offering single, dual, and quad inputs, respectively. The HDLT series encoders come with features like programmable channel and network names, adjustable output and logic channel numbering (LCN), front-mounted LCD display for easy configuration, and rack mountability.

advertisement

Assistant Bot

Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.

HD Digital Encoder / Modulator HDLT 1801, HDLT 2801, HDLT 4802 User Guide and Installation Manual | Manualzz

HDLT Series Encoder/Modulators

HDLT-1801, HDLT-2801, HDLT-4802

User Guide and Installation Manual

FENGER

®

Distributed by

KOSMOSAT SA

1 Nireos Str. Paleo Faliro | Attica 17561 | Greece

Tel +30 210 98 48 058 | Fax +30 210 98 83 730 [email protected]

| www.kosmosat.gr

1 HDLT Series Manual V1.0

Content

Safety Precautions .......................................................................................................................................... 3

Package Contents ........................................................................................................................................... 3

Product Description........................................................................................................................................ 4

Features .......................................................................................................................................................... 4

Specifications ................................................................................................................................................. 5

Installation ...................................................................................................................................................... 6

Hardware Installations and Connections ...................................................................................................6

DEVICE Programming and Setup ............................................................................................................7

Connecting to the GUI Interface: ................................................................................................................... 7

Encoder Programming and Setup via GUI Interface: .................................................................................... 7

Overview Page of Fenger Encoder ............................................................................................................8

Common Setup ..........................................................................................................................................9

RFSetup ..................................................................................................................................................10

Encoder Setup ......................................................................................................................................... 11

IP Streaming Setup ..................................................................................................................................12

Network Configuration ...........................................................................................................................13

Administration .........................................................................................................................................14

Saving your configuration files .................................................................................................................... 15

Front Panel LCD Encoder Menu Map ......................................................................................................... 16

Modulator Configuration via Front Panel LCD ........................................................................................... 17

Product Notes: .............................................................................................................................................. 24

FENGER

®

2 HDLT Series Manual V1.0

Safety Precautions

The presence of this symbol is to alert the installer and user to the presence of uninsulated dangerous voltages within the product’s enclosure that may be of sufficient magnitude to produce a risk of electric shock.

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS DEVICE

TO RAIN OR MOISTURE. DO NOT OPEN THE UNIT. REFER SERVICING TO QUALIFIED

PERSONNEL ONLY.

 DO NOT apply power to the unit until all connections have been made, all components have been installed and all wiring has been properly terminated.

 DO NOT terminate, change or uninstall any wiring without first disconnecting the unit’s power adapter from the device.

 This device is supplied with the appropriately rated power supply. The use of any other power supply could cause damage and invalidate the manufacturer’s warranty.

 DO NOT connect the power cord to the device if the power cord is damaged.

 DO NOT cut the power cord.

 DO NOT plug the power cord into an AC outlet until all cables and connections to the device have been properly connected.

 The device should be installed in an environment consistent with its operating temperature specifications. Placement next to heating devices and ducts is to be avoided as doing so may cause damage. The device should not be placed in areas of high humidity.

 DO NOT cover any of the device’s ventilation openings.

 DO NOT cover or obstruct the device’s fan or fan openings.

If the device has been in a cold environment allow it to warm to room temperature for at least 2 hours before connecting to an AC outlet.

Package Contents

This package contains:

 One HDLT-1801, or HDLT-2801, or HDLT-4802 RF / IP Encoder / Modulator

 One Power Cable

 One Installation / Configuration Manual

Inspect the package before starting installation to ensure there is no damage and all supplied contents are present. Contact your distributor or dealer should the device be damaged or package contents are incomplete.

FENGER

®

3 HDLT Series Manual V1.0

Product Description

Fenger's

HDLT series digital Encodulators convert Digital Video Broadcasting (DVB-T) High

Definition video and audio signals to COFDM. The Dual Mode HDLT series Encodulators provide single, dual, and quad inputs, respectively. All units feature programmable channel and network names. Adjustable output and adjustable logic channel numbering (LCN) are standard features. The unit's front-mounted LCD display and controls allow for easy configuration and adjustments.

The HDLT Encodulators are perfect for multi-video distribution solutions in the commercial market (hotels, motels, sports bars, restaurants, hospitals, casinos, business and university campuses, digital signage, etc.) as well as home entertainment systems.

Features

HDMI, Component, and Composite inputs with auto detection

Dual Mode MPEG4/H.264 AVC and MPEG2 selectable

Video resolution: 1080i/720p/576p/576i/480p/480i for both MPEG2 and MPEG4/H.264, while

1080p for MPEG4/H.264 only

Perfect, clean, and clear picture on fast moving video, sports, text crawls/rolls, etc.

GigE output port

Front Panel LCD for easy setup

Rack Mountable for easy installation

Easily replacing an Analogue Modulator installation with

Fenger

s Digital Encodulator

FENGER

®

4 HDLT Series Manual V1.0

Specifications

DVB-T (COFDM)

HDLT-1801 HDLT-2801 HDLT-4802

Input

1-Input, 1-RF Output 2-Input, 1-RF Output 4-Input, 2-RF Output

Input Connectors

Input Impedance

RF Output

Standard

HDMI input (Video + Audio)

YPbPr component input (Video)

Composite input (Video)

Left and Right channel input (Audio)

75 Ohm

DVB-T according to EN 300 744

Frequency Range

Channel Bandwidth

MER

Output Level

Output Level

Adjustment

Output Impedance

Output Connector

IP Output

Streaming Method

Output Connector

Modulation

E2 (50.5MHz) ~ S20 (296.5MHz) with 7 MHz interval

S21 (306MHz) ~ E69 (858MHz) with 8 MHz interval

7 MHz, 8 MHz

>42dB typical

105 dBuV typical

0 to -20dB (1dB step)

75 Ohm

"F" female

RTP/UDP Unicast, RTP/UDP Multicast

RJ-45, 1Gbps

Video Resolution

1080i/720p/576p/576i/480p/480i for both MPEG-2 and MPEG-4/AVC H.264,

1080p for MPEG-4/AVC H.264 only

Video Compression

Audio Compression

LCN

Carrier (OFDM Mode)

Guard Intervals

MPEG-2, MP@HL / MPEG-4/AVC H.264, MP@Level4

MPEG-1 Layer II / AAC, AC3 Pass through

Yes

2K, 8K

1/32

7/8 Code Rate (FEC) 1/2, 2/3, 3/4, 5/6, 7/8

Constellations

Interface

Local Setup

Remote Management

General

Language

Power Supply

7/8

64 QAM

LCD Display + keypad via Web Browser from any PC

English

100 to 240 VAC, 50/60 Hz

Consumption

Temperature Rating

Dimensions

Weight

15.6 Watts

3.50 Kilograms

21.0 Watts

0ºC to +45ºC

482.7mm x 240mm x 44.4mm, 1RU

3.70 Kilograms

26.4 Watts

4.00 Kilograms

*Subject to change without notifications

FENGER

®

5 HDLT Series Manual V1.0

Installation

System Installer must adhere to Article 820-40 of the NEC that provides guidelines for proper grounding and specifies that the cable ground shall be connected to the grounding system of the

building, as close to the point of cable entry as possible.

Unpacking and Inspection

Each unit is shipped factory tested. Ensure all items are removed from the container prior to discarding any packing material.

Thoroughly inspect the unit for shipping damage with particular attention to connectors and controls. If there is any sign of damage to the unit or damaged or loose connectors contact your distributor immediately. Do not put the equipment into service if there is any indication of defect or damage.

Hardware Installations and Connections

It is highly recommended that quality cables and connectors be used for all video and audio source connections.

1. The unit is designed to be rack mounted in a standard EIA 19” rack.

2. The unit comes standard with HDMI, Component, and Composite video inputs. The HDLT encoder / modulator are intelligently designed to detect the video input from the video source.

HDMI Connection: Connect the HDMI cable(s) from the video source(s) into the HDMI input(s). If using a Component Video Cable, connect the Y (Green), Pb (Blue), and Pr (Red) video source cable to the unit’s Component input ports. If using a Composite Video source, use a

75Ω coaxial cable with RCA connectors to connect the video source (e.g., CATV, DVD, VCR,

Camera) to the unit’s CVBS port (IN1…IN2, IN3, IN4 depending on your model).

Repeat this step for each video source connection.

3. Component / Composite Audio inputs: Connect A/V audio input (Left / Right Audio) use RCA cables to connect the audio source to the red / white AUDIO L and AUDIO R INPUT jacks

(IN1…IN2, IN3, IN4 depending on your model). Repeat this step for each audio source connection.

Be sure the video and audio connections for each source are consistent with the unit’s inputs

(IN1…IN2, IN3, IN4 depending on your model).

4.

Use a quality 75Ω coaxial cable with “F” connectors from the unit’s RF OUT jack to the

distribution system (combiner or reverse splitter) or directly to a television.

5. If your device is equipped with an IP output- connect the Ethernet cable to the IP output RJ-45 connector.

6.

Connect the included power cord to the unit’s POWER plug.

7. Connect the power cord to an appropriately rated AC power outlet.

FENGER

®

6 HDLT Series Manual V1.0

DEVICE Programming and Setup

To setup and program the Encoder you can use the GUI interface or the LCD Front Panel

Connecting to the GUI Interface:

1. Connect an Ethernet cable directly (no Cross Over cable required) to the Web Management Port on the rear panel of the encoder or connect the Ethernet cable to an Ethernet switch. Connect an

Ethernet Cable to your PC.

2. Using a Windows-based PC Select Windows Icon

3. Go to My Computer

4. Select Network

5. Allow UPnP to locate and list the device(s) in the right panel

6. Right Click and Select “View device Webpage”.

Note: To setup the encoder using the Front Panel LCD see “Modulator Configuration via

Front Panel LCD”.

Encoder Programming and Setup via GUI Interface

:

After connecting the device to the “Web Management” port located on the rear of the device and locating the device via the 'Network' tool in 'My Computer'

Step 1:

Right Click and Select “View device Webpage”

Overview Page of Fenger Encoder

FENGER

®

7 HDLT Series Manual V1.0

Welcome page showing overview status of the Encoder when fully functioning.

Alternate between viewing status of RF Output 1 and RF Output 2 (Quad Version) by selecting the RF

Output section of the device you want to monitor.

Note: Image displays the Quad version of the super LS HD Encoder.

Step 2: Login

Select Common Setup

Once the Common Setup Tab is selected you will be prompted to enter the user name and password for device.

Login Password:

Default User Name: admin

Default Password: Admin123

Note: To change the Password for the GUI go to the Administration Tab

Step 3: Common Setup Tab

Common Setup

Use the Common Setup Page to set the Output channel, Attenuation, Enable VCN Mode, and Device Address.

FENGER

®

8 HDLT Series Manual V1.0

Step 4: Local Save

Perform a Local Save once all parameters are set.

Notes on Changes:

Changes made to an individual setup tab may require the installer to perform a Local Save AND Upload

and Reboot to the device if you are only making changes to one parameter of the encoder.

Example: Installer is required to change only the output channel for the device (No other changes to the device are required). Once the channel has been changed, the installer is required to perform 1) Local

Save AND 2) Upload and Reboot.

Notes on Channel Selection:

The image below shows the Output Channel is set to CH # E21.

RF1 will output 1 QAM signal carrying up to 2 digital audio/video channels (within your device's

Bandwidth settings). The device will automatically set RF2 to Ch # E22 for a Quad unit.

The below diagram depicts how each input on the Quad Encoder is placed in RF1 or RF2.

Note: The RF2 Physical Channel Output is determined by the selection of output channel of RF1.

RF1 RF2

IN-1

IN-2

CH # E21

IN-3

IN-4

CH # E22

Note: The Quad Encoder prevents you from selecting the last channel in the device as the first physical channel for the device's output channel. For 7MHz bandwidth, select CH # S19(289.5MHz) for the output channel and the device will automatically set RF2 as CH # S20 (296.5MHz). For 8MHz, select CH # E68

(850MHz) for the output channel and the device will automatically set RF2 as CH # E69 (858MHz).

Setting the Output Channel to CH# S19 / CH#E68 would result in the following RF1/RF2 configuration.

RF1 RF2

IN-1

IN-2

IN-3

IN-4

CH # S19 CH # S20

CH # E68 CH # E69

FENGER

®

9 HDLT Series Manual V1.0

Step 5: RF Setup

RF Setup

Use the RF Setup Page to setup each RF Output.

Select RF Output 1 or RF Output 2 (Quad Unit shown).

Select and set the required parameters you require for your installation.

Step 6: Local Save

Perform a Local Save once all parameters are set.

Step 7: Encoder Setup

Encoder Setup

Select the Encoder 1, 2, 3, 4 tab to program an individual encoder. Select and change all desired parameters.

NOTE: There will be an Encoder tab present for each input on the device.

FENGER

®

10 HDLT Series Manual V1.0

Step 8: Local Save for each Encoder tab

Perform a Local Save on EACH Encoder Tab where changes were performed.

***** Ensure all Encoder tab changes have been locally saved

FENGER

®

11 HDLT Series Manual V1.0

Step 9: IP Streaming

IP Streaming Setup

** Your device may not be IP Streaming capable- if not move to the next step.

Use the IP Streaming setup page to set your device's IP streaming IP Address, and select your streaming method protocol and Destination IP, Port, and TTL settings.

The Quad Encoder allows the integrator to create 2 Destination IP Addresses. Two (2) video streams will be carried on each Destination IP address (Shown below).

Step 10: Local Save

Perform a Local Save once all parameters are set.

***** Ensure all Encoder changes have been locally saved before performing Step 11.

FENGER

®

12 HDLT Series Manual V1.0

Step 11: Upload and Reboot

Once all the encoder's settings are changed and a Local Save performed for each Setup tab Select

Upload and Reboot” on the IP Streaming page. This function will upload and save all parameters set in the Common, RF, Encoder, IP Streaming sections of the device. Your device will quickly reboot.

Reminder: If changing only a setting on a specific setup page- remember to perform a Local Save and

Upload and Reboot.

We highly recommend you save your encoder configuration files. See Administration tab for how to back up your settings.

Step 12: Network Configuration Tab

Network Configuration

Use the Network Setup Tab to configure the device’s IP address, Subnet Mask, Gateway, Enable/Disable

DHCP, and set Host Name.

Step 13: Save Network Configuration

Save Config: Once all parameters are set you are required to select Save Config. This function will reboot and save the changes setting for the Network Configuration.

Note: Only the Network Configuration changes will be saved.

FENGER

®

13 HDLT Series Manual V1.0

Step 14: Administration

Administration

Administration Page Functions

Reboot

Reset to Default

Backup

Upload

New Password

FENGER

®

Actions

Reboot device. All unsaved settings will be lost.

Reset all settings back to original factory settings

Download all settings of device

Upload a saved config file

Create and save new password for GUI

14 HDLT Series Manual V1.0

****Caution****

Selecting “Reset to Default” will automatically reset all saved settings back to factory default

settings. All saved settings will be lost.

****Caution****

Step 15:

If required- change GUI Password and Submit.

Note: When setting a new password you must use the Submit button.

This password is for access to the GUI only. The LCD front Panel Password will not be changed and is set to prevent unauthorized users access to your device.

Saving your configuration files

We highly recommend you save your encoder configuration files. Simply Click the “Backup” button and the config files will be saved to your computer.

To upload a configuration file- simply click “Choose File” then locate the file you want to upload. Click

Upload” to install the configuration files. This function is helpful to the installer when installing a large number of encoders in a single system.

FENGER

®

15 HDLT Series Manual V1.0

Front Panel LCD Encoder Menu Map

Common

Setup

Output

Channel

Attenuation

LCN Mode

Device

Address

Default

Config

Back to Main

RF Setup

Select RF

Enable RF

Constellation

FEC

Guard

Interval

OFDM Mode

RF Output

Cell ID

RF TS ID

Network ID

Org Network

ID

Network

Name

Back to Main

Main Menu

Encoder

Setup

Select

Encoder

Video Input

Program

Num

Channel

Name

Provider

Name

LCN

Aspect Ratio

Video Output

HDCP

Audio Input

Audio

Output

Closed

Caption

Brightness

Contrast

Saturation

Hue

Back to Main

IP Streaming

Setup

Network

Setup

Streaming

Setup

Back to Main

(IP Streaming Sub Menus)

Network

Setup Menu

DHCP

IP Address

Subnet Mask

Gateway

Back to IP

Streaming

Web Mngt

Setup

DHCP

IP Address

Subnet Mask

Gateway

Back to Main

Streaming

Setup Menu

Select IP

Output

Enable

Streaming

Streaming

Method

Destination

IP

Destination

Port

Time to Live

Back to IP

Streaming

FENGER

®

16

Exit

HDLT Series Manual V1.0

Modulator Configuration via Front Panel LCD

Once the encoder is powered up it will go through its initial booting process. Once the unit has completed its initial “Booting” up process the LCD will display IN-1..., Bit Rate information, Channel-1...., and other information in the LCD Display Window. When visible the unit is ready for programming or operation.

The LCD will display data as it cycles through the available information.

Screen Views:

1: Inputs, Mbps, Channel Names, Video Output Type, Audio Output type

IN-1 8.573Mbps CHANNEL-1 MPEG2 MP2

IN-2 8.573Mbps CHANNEL-2 MPEG2 MP2

Note: If your device is a QUAD version the below screen will display all input data as is cycles through the data available.

2: Use the Scroll Up/Down button to display RF-1 / RF-2 data, Physical Output Channel, Constellation,

FEC setting, OFDM Mode Selection.

RF-1 E21 (474 MHz) QAM 64 7/8 1/32 8K

RF-2 E22 (482 MHz) QAM 64 7/8 1/32 8K

3: Use the Scroll Up/Down button to display IP address

1st DESTINATION IP 192.168. 1. 20

1st DESTINATION PORT 10000

Main Menu

– To access the Main Menu first enter the password by pressing the OK button. Use the Scroll

Up/Down buttons to enter the password. Once the password is entered press the OK button again and the

LCD Screen will display “Main Menu Common Setup”.

Password –

Use the Scroll Up/Down buttons to enter the password. Password is 0000. Press the OK button for each number to enter the password. Press OK again after the display shows …... HD Series.

PASSWORD=?

0

FENGER

®

17 HDLT Series Manual V1.0

Common Setup Menu

Output Channel – Use the Scroll Up/Down button to change the output channel. Use the

Scroll Up/Down buttons to select the desired output channel. Once the desired output channel is selected press the OK button to set the channel.

The LCD Display will show both the channel number and the frequency number of the output channel (example: E21 474 MHz)

Note: The RF2 Channel Physical output is determined by the selection of output channel of RF1

The Quad Encoder prevents you from selecting the last channel in the device. **See Notes

on Channel Selection for more information on this topic

Attenuation – Use the Scroll Up/Down button to select Attenuation. Press the OK button to enter the Attenuation menu. Use the Scroll/Up down button to select the desired attenuation in 1dB increments from 0 to minus 20 dB. Once the desired attenuation level is found press the OK button to set.

LCN

– Use the Scroll Up/Down button to select LCN MODE. Press the OK button to enter the LCN menu. Menu options are APN, NORDIG, ITC, EACEM, AU, and NZ.

Factory default: ITC. Use the Scroll Up/Down button to select the desired LCN and press the OK button to set.

Device Address – Use the Scroll Up/Down button to select Device Address. Press the OK button to enter the Device Address menu. Use the Scroll Up/Down to select the Desired

Address ranging from 1 to 255 then press OK to set. A unique device address is required if setting up more than 1 encoder per site. This allows the user to distinguish each device.

Default Configuration –To reset the Encoder/Modulator back to the factory default select the Default Configuration Menu. Press OK to enter the Default Configuration Menu.

Using the Up/Down button select YES to reset all programmed settings back to the factory default setting. Factory Default: NO.

Caution: Once the “YES” button is pressed the unit will automatically reset to the factory default settings. All settings or changes to the encoder/modulator will be lost. 

Back to Main- Select Back to Main to escape the Common Setup Menu.

RF Setup Menu

Select RF- Press the OK button to enter the Select RF menu. Use the Scroll Up/Down button to Select the RF section of the Encoder. Select 1 or Select 2.

The Single and Dual versions of this product will have Select 1 only.

RF SETUP

SELECT RF

1

Enable RF – Use the Scroll Up/Down button to select Enable RF. Press the OK button to enter the Enable RF menu. Select Enable/Disable, then press the OK button to set. Factory default is Enable.

Constellation – Use the Scroll Up/Down button to select Constellation. Press the OK button to enter the Constellation menu. Select the desired Constellation / QAM setting then press the OK button to set.

FENGER

®

18 HDLT Series Manual V1.0

FEC

-

Use the Scroll Up/Down button to select the FEC menu. Press the OK button to enter the FEC menu. Use the Scroll Up/Down button to select the desired FEC setting and press the OK button to set.

GUARD INTERVAL

– Use the Scroll Up/Down button to select Guard Interval. Press the

OK button to enter the Guard Interval menu. Use the Scroll Up/Down button to select the desired Guard Interval and press the OK button to set.

OFDM - Use the Scroll Up/Down button to select the OFDM menu. Press the OK button to enter the OFDM menu. Use the Scroll Up/Down to select the OFDM 2K or 8K. Press

OK to set.

RF Output

Use the Scroll Up/Down button to select RF Output. Press the OK button to enter the RF Output menu. Menu options are Normal, Inverted and C.W. The factory default is Normal. Use the Scroll Up/Down button to select the desired RF Output and press the OK button to set.

CELL ID

– Use the Scroll Up/Down button to select CELL ID. Press the OK button to enter the CELL ID menu. Use the Scroll Up/Down button to select the desired CELL ID ranging from 0 to 65535 then press the OK button to set. Factory default is 0.

RF TS ID – Use the Scroll Up/Down button to select TS ID. Press the OK button to enter the TS ID menu. Use the Scroll Up/Down button to select the desired Stream ID ranging from 0 to 65535 then press the OK button to set.

Network ID – Use the Scroll Up/Down button to select Network ID. Press the OK button to enter the Network ID menu. Use the Scroll Up/Down button to select the desired

Network ID ranging from 0 to 65535 then press the OK button to set.

ORG Network ID – Use the Scroll Up/Down button to select ORG Network ID. Press the

OK button to enter the ORG Network ID menu. Use the Scroll Up/Down button to select the desired ID ranging from 0 to 65535 then press the OK button to set.

Network Name – Use the Scroll Up/Down button to select Network Name. Press the OK button to enter the Network Name menu. Use the Scroll Up/Down button to select the first character for the desired Network Name then press the OK button to set. Repeat the process for each character in the desired Network Name. A Network Name can consist up to 16 characters.

Back to Main- Select Back to Main to escape the RF Setup Menu.

Encoder Setup Menu

 Select Encoder

Use the Scroll Up/Down button to select Select Encoder. Press the

OK button to enter the Select Encoder menu. Use the Scroll Up/Down button to select the desire encoder 1,2,3,4. Press the OK button to set.

 Video Input

Use the Scroll Up/Down button to select Video Input. Press the

OK button to enter the Video Input menu. Use the Scroll Up/Down button to select the Video Input option: Auto, HDMI, Component, or Composite. Factory default: Auto. Press the OK button to set.

Program Num -

Use the Scroll Up/Down button to set 1 Program Num (Number).

Press the OK button to enter the Program Num menu. Use the Scroll Up/Down to select the

Program Num ranging from 1 to 65535 then press OK to set. 

Channel Name

– Use the Scroll Up/Down button to select Channel Name. Press the OK

FENGER

®

19 HDLT Series Manual V1.0

FENGER

® button to enter the Channel Name menu. Use the Scroll Up/Down menu to select the first character of the desired Channel Name then press the OK button to set. Repeat the process until the Channel Name is completed.

The Channel Name can be 7 characters long. Factory Default: CHANNEL-1, CHANNEL-

2, CHANNEL-3, CHANNEL-4.

PROVIDER NAME – Use the Scroll Up/Down button to select Provider Name. Press the

OK button to enter the Provider Name menu. Use the Scroll Up/Down menu to select the first character of the desired Provider Name then press the OK button to set. Repeat the process until the Provider Name is completed. The Provider Name can be 16 characters long.

LCN-Use the Scroll Up/Down button to set LCN. Press the OK button to enter The Source

ID menu. Use the Scroll Up/Down to set the Source ID. Range: 1 to 999. Press OK to set.



Aspect Ratio – Use the Scroll Up/Down button to select Aspect Ratio. Press the OK button to enter the Aspect Ratio menu. Use the Scroll Up/Down button to select the desired

Aspect Ratio option of 4:3 or 16:9 then press the OK button to set.

Video Output – Encoder / Modulators may be Dual MODE Capable. The user may select to output video in either MPEG2 or H.264 (MPEG4). Use the Scroll Up/Down button to select Video Output. Press the OK button to enter the Video Output menu. Use the Scroll

Up/Down button to select the Video Output option: MPEG2 CBR or H.264 CBR. Press the

OK button to set.

Note: The Dual and Quad Input allows the installer to select a combination of Video

Output formats. Some versions of this device will allow the user to have both outputs broadcasting in either MPEG2 or H.264 (MPEG4) or a combination of both MPEG2 and

H.264 (MPEG4).

Note: The H.264 version of this device is set to H.264 Video Output.

HDCP- Use the Scroll Up/Down button to select the HDCP menu- Use the Scroll

Up/Down button to select the HDCP menu. Press the OK button to enter the HDCP menu.

Select Enable / Disable. Each Encoder will require you to Enable the HDCP option.

NOTE: It is the installers / property owner / integrator's responsibility to contract with the service provider regarding content authorization and the use of HDCP. 

Audio Input – Use the Scroll Up/Down button to select. Press the OK button to enter the

Audio Input menu. Use the Scroll Up/Down button to select the Audio Input option: Auto, or Analog. Factory Set: Auto.

Audio Output

Use the Scroll Up/Down button to select Audio Output. Press the OK button to enter the Audio Output menu. Use the Scroll Up/Down button to select the Audio

Output option: MP2 (MPEG2 Layer I Audio), AAC, or AC3. Factory default: MP2. Press the OK button to set.

Some versions of the HDLT Encoder will not allow you to select AC3 as an option.

Contact your Distributor if you require an AC3 version of this device.

Closed Caption-

Use the Scroll Up/Down button to select the Closed Caption Menu. Press the OK button to enter the Closed Caption menu. Enable / Disable Closed Caption control.

Each Encoder will require you to Enable the Closed Caption option if you require Closed

Captioning Support on a particular video output.

NOTE: WHEN USING CLOSED CAPTIONING- USER MUST CONNECT FROM THE

20 HDLT Series Manual V1.0

CONTENT SOURCE THE COMPOSITE OUTPUT OR CC OUTPUT SOURCE TO THE

ENCODER'S CVBS INPUT CONNECTOR.

Brightness – Use the Scroll Up/Down button to select Brightness. Press the OK button to enter the Brightness menu. Use the Scroll Up/Down button to select the desired Brightness value (0 to 255) and press the OK button to set. Factory default: 128.

Contrast – Use the Scroll Up/Down button to select Contrast. Press the OK button to enter the Contrast menu. Use the Scroll Up/Down button to select the desired Contrast value (0 to 255) and press the OK button to set. Factory default: 128.



Saturation

– Use the Scroll Up/Down button to select Saturation. Press the OK button to enter the Saturation menu. Use the Scroll Up/Down button to select the desired Saturation value (0 to 255) and press the OK button to set. Factory default: 128.

Hue – Use the Scroll Up/Down button to select Hue. Press the OK button to enter the Hue menu. Use the Scroll Up/Down button to select the desired Hue value (0 to 255) and press the OK button to set. Factory default: 128.

Back to Main- Select Back to Main to escape the Encoder Setup Menu.

IP Streaming Setup

-Network Setup

DHCP – Use the Scroll Up/Down button to select DHCP. Press the OK button to enter the

DHCP menu. Use the Scroll Up/Down button to Enable/Disable. Press the OK button to set.

IP Address – Use the Scroll Up/Down button to select IP Address. Press the OK button to enter the IP Address menu. Use the Scroll Up/Down button to enter the IP Address. Use the

Scroll Up/Down menu to select the desired IP Address then press the OK button to set.

Repeat the process until the IP Address is completed. Press the OK button to set. Note: If

DHCP is enabled you will not be able to set an IP address. Select DHCP disabled if Static

IP Address required.

Subnet Mask – Use the Scroll Up/Down button to select Subnet Mask. Press the OK button to enter the Subnet Mask menu. Use the Scroll Up/Down button to enter the Subnet

Mask. Use the Scroll Up/Down menu to select the first number of the desired Subnet Mask then press the OK button to set. Repeat the process until the Subnet Mask is completed.

Press the OK button to set.

Gateway – Use the Scroll Up/Down button to select Gateway Address. Press the OK button to enter the Gateway Address menu. Use the Scroll Up/Down button to enter the

Gateway Address. Use the Scroll Up/Down menu to select the first number of the desired

Gateway Address then press the OK button to set. Repeat the process until the Gateway

Address is completed. Press the OK button to set.

Back to Main- Select Back to Main to escape the Web Management Network Setup

Menu.

FENGER

®

21 HDLT Series Manual V1.0

Streaming Setup

Select IP Output – Use the Scroll Up/Down button to select IP Output. Press the OK button to enter the IP Output menu. Use the Scroll Up/Down button to Select the IP

Output. Select 1 ~ 4. Press the OK button to set.

Enable Streaming –Use the Scroll Up/Down button to select Enable Streaming. Press the

OK button to enter the Enable Streaming menu. Use the Scroll Up/Down button to

Enable/Disable. Press the OK button to set.

Streaming Method – Use the Scroll Up/Down button to select Streaming Method. Press the OK button to enter the Streaming Method menu. Use the Scroll Up/Down button to select the Streaming Method required. Select: UDP UNICAST, RTP UNICAST, UDP

MULTICAST, or RPT MULTICAST. Press the OK button to set.

1

st

Destination IP – Use the Scroll Up/Down button to select 1 st

Destination IP (Address).

Press the OK button to enter the 1 st

Destination IP Address menu. Use the Scroll Up/Down button to set the Destination IP Address. Note: By selecting Unicast in the Streaming

Method Menu the default address begins at 192.168.1.20. Use the Scroll Up/Down button to set the Destination IP Address. Press the OK button to set. Multicast begins at

224.1.1.1. Press the OK button to set.

Destination IP Address Range(s):

Unicast: 0.0.0.0 ~ 223.255.255.255

Multicast: 224.0.0.0 ~ 239.255.255.255

1

st

Destination Port – Use the Scroll Up/Down button to select DES Port Number

(Destination Port Number). Press the OK button to enter the 1 st

Destination Port Number menu. Use the Scroll Up/Down button to set. Press the OK button to set.

For 2 IP Version Only ( 2 nd

Destination IP / 2 nd

Destination Port) Functions

2

nd

Destination IP – Use the Scroll Up/Down button to select 2

(Address). Press the OK button to enter the 2 nd nd

Destination IP

Destination IP Address menu. Use the

Scroll Up/Down button to set the Destination IP Address. Note: By selecting Unicast in the

Streaming Method Menu the default address begins at 192.168.1.21. Use the Scroll

Up/Down button to set the Destination IP Address. Press the OK button to set. Multicast begins at 224.1.1.2. Press the OK button to set.

Time To Live – Use the Scroll Up/Down button to select Time To Live menu. Press the

OK button to enter the Time To Live .menu. Use the Scroll Up/Down button to select TTL.

Press the OK button to set. Default Settings: Unicast: 63. Multicast: 4. TTL Range: 1~ 255.

Back to Main- Select Back to Main to escape the Streaming - IP Streaming Sub Menu.

FENGER

®

22 HDLT Series Manual V1.0

Web Management Network Setup

DHCP – Use the Scroll Up/Down button to select DHCP. Press the OK button to enter the

DHCP menu. Use the Scroll Up/Down button to Enable/Disable. Press the OK button to set.

IP Address – Use the Scroll Up/Down button to select IP Address. Press the OK button to enter the IP Address menu. Use the Scroll Up/Down button to enter the IP Address. Use the

Scroll Up/Down menu to select the desired IP Address then press the OK button to set.

Repeat the process until the IP Address is completed. Press the OK button to set. Note: If

DHCP is enabled you will not be able to set an IP address. Select DHCP disabled if Static

IP Address required.

Subnet Mask – Use the Scroll Up/Down button to select Subnet Mask. Press the OK button to enter the Subnet Mask menu. Use the Scroll Up/Down button to enter the Subnet

Mask. Use the Scroll Up/Down menu to select the first number of the desired Subnet Mask then press the OK button to set. Repeat the process until the Subnet Mask is completed.

Press the OK button to set.

Gateway Address – Use the Scroll Up/Down button to select Gateway Address. Press the

OK button to enter the Gateway Address menu. Use the Scroll Up/Down button to enter the Gateway Address. Use the Scroll Up/Down menu to select the first number of the desired Gateway Address then press the OK button to set. Repeat the process until the

Gateway Address is completed. Press the OK button to set.

Back to Main- Select Back to Main to escape the Web Management Network Setup

Menu.

FENGER

®

23 HDLT Series Manual V1.0

Product Notes:

Item Value

Password

Serial Number

Installation Date

Purchase Date

Video Input 1

Video Input 2

Video Input 3

Video Input 4

************************************************************************************

DECLARATION OF CONFORMITY

Hereby, KOSMOSAT SA confirms that the products HDLT-1801, HDLT-2801, and HDLT-4802 (HD

Digital Encoder / Modulators with IP) conform to relevant EEC harmonized standards and consequently can carry CE-mark.

Relevant harmonized standards:

EN 55013:2001+A1:2003+A2:2006 Class B

EN 55020:2007+A11:2011

EN 60065:2002

FENGER

®

24 HDLT Series Manual V1.0

advertisement

Key Features

  • DVB-T (COFDM)
  • HDMI, Component, and Composite inputs
  • Dual Mode MPEG4/H.264 AVC and MPEG2 selectable
  • Video resolution: 1080i/720p/576p/576i/480p/480i
  • GigE output port
  • Front Panel LCD for easy setup
  • Rack Mountable for easy installation
  • IP Streaming

Frequently Answers and Questions

What is the purpose of the HDLT series encoder / modulator?
The HDLT series encoder / modulator converts digital video broadcasting (DVB-T) high-definition video and audio signals to COFDM, enabling distribution of video signals over RF or IP networks.
Does the HDLT series encoder / modulator support multiple input sources?
Yes, the HDLT series offers single, dual, and quad input options, allowing you to connect multiple video sources.
What are the available video output resolutions for the HDLT series encoder / modulator?
The HDLT series supports various resolutions, including 1080i/720p/576p/576i/480p/480i for both MPEG2 and MPEG4/H.264, and 1080p for MPEG4/H.264 only.
How can I configure and manage the HDLT series encoder / modulator?
The encoder features a front-mounted LCD display and controls for easy configuration and adjustments, as well as a web-based GUI interface for remote management.
Does the HDLT series encoder / modulator support IP streaming?
Yes, the HDLT series offers IP streaming capabilities, allowing you to distribute video signals over a network.

Related manuals

Download PDF

advertisement