ASHCROFT digital industrial gauge Operating Instructions
Below you will find brief information for digital industrial gauge. This digital gauge offers a menu-driven display for easy customization. User selectable features include 12 units of measurement, password protected calibration and disable functions, adjustable bar graph and update rate. A five-digit display for maximum resolution is standard. Optional 4-20mA output, switching and line-power add to the versatility of the gauge. With the range printed on the keypad, Ashcroft digital gauges meet ASME B40.7 specification.
PDF
Download
Document
Advertisement
Advertisement
| | I&M008-10109-DIG New 8/07 > 2/8/06 2:22 PM Page 1 Safe” WASHCROFT Digital Industrial Gauge Operating Instructions 14M008-10109-2/06 dwg. 83B234-01 Rev. B 12/04 I&M008-10109-DIG New 8/03 2/8/06 2:22 PM "ес +) Congratulations on your purchase of the Ashcrofté digital industrial gauge. This feature-packed gauge offers a menu-driven display for easy customization. User selectable features include 12 units of measure- ment, password protected calibration and disable functions, adjustable bar graph and update rate. A five digit display for maximum resolution is standard. Optional 4-20mA output, switching and line- power add to the versatility of the gauge. With the range printed on the keypad, Ashcroft digital gauges meet ASME B40.7 specification. See a complete listing of product features and specifications on pages 16. TABLE OF CONTENTS Quick Reference Keypad Functions * ON/OFF KEY * /ERO/CLEAR KEY * MIN/MAX KEY V (down arrow key) * MENU KEY * BACKLITE KEY A (up arrow key) * ENTER KEY MENU Functions (MENU Mode) * Engineering Units * CONFIG Mode * Set Password * Recalibration of Gauge * Zero Key Adjustment * Disabling Menu Options * Bar Graph Options * Auto Off Options * Update Options for Displayed Pressure * Dampening Options * Backlite Options (Backlite Optional) * Set Switch(es) Option(s) (Switches Optional) Specifications Display Messages . Wiring Diagrams Gauge Installation & Maintenance........................ 24 * Mounting * Battery Replacement & Installation 1&M008-10109-DIG New 8/03 2/8/06 2:22 PM Page 4 ; > — QUICK REFERENCE -88 “high digital display (4% ase) .60 high digital display(3” case) Bar graph % of full scale Flashing display when unit pressured below zero Press to indicate minimum or maximum pressure gauge has measured Press again to return to pressure units | Press to turn unit on or off | While in unit of measurement mode (eg: psi), press the ZERO CLEAR button to rezero the gauge. This feature functions when displayed pressure is within +5% or 10% of zero value Flashing display when unit pressurized beyond full-scale | This bar graph indicates battery level; the more segments, the closer the battery is to full charge (only dis- played on units with battery Press to turn backlite on or off (backlite optional) Range on keypad, | Press to read menu complies with ASME B40.7 + > UPDATE RATE AUTO OFF + > T UNITS (Pressure) (Pressure measurement (Turns unit off after | | ENGLISH per second) option selected) CALIBRATE | INHG 10x (100 MS)* Never Zero and span PSI* 5x (200 MS) 2 minutes adjustments, „INH2O 2х (500 М5) 5 minutes password @ 4°C, 20°C, 60°F 1х (1 Sec) 15 minutes protected fii 30 minutes METRIC BAR BACKLITE MBAR (Off options) DAMPENING KPA Never (Takes pressure reading CMH20 2 SEC and averages KG/CM2 5 SEC* process pressure DISABLE 30 MIN ОИ” О Avg 2 “lockout” of Avg 4 MENU Avg 6 options Avg 8 *Indicates Default — 4 — — 5 — T&M008-10109-DIG New 8/03 12/8/06 2:22 PM еее ©), о ON/OFF as KEYPAD FUNCTIONS Turns the gauge on and off. When pressing the ON/OFF key while in the off position, gauge start- up display first indicates the software version followed by the model number and gauge pres- sure range. The gauge will then display indicated pressure and be ready for use. Press this key for one second prior to gauge usage to rezero any initial zero shift. If zero shift is greater than programmed zero allowance, the gauge will display OFSET (blinking) for 1 sec- ond, then return to the measure mode. To clear minimum and maximum values, press ZERO/CLR button (when min/max values are indicated). Gauge will auto advance once zeroed. The Max/Min key allows review of minimum and maximum pressure values since unit start-up or last push of the clear key. Press key to: 1) Indicate maximum pressure. 2) Indicate minimum pressure. 3) Exit MAX/MIN mode and return the unit to pressure measurement mode. To clear mini- mum and maximum values press ZERO/CLR key (must be in MAX/MIN mode). The Y (down arrow key) is used in the MENU mode, see following MENU key section. A Key for gauge with Backlite Key for gauge without Backlite displayed with A (up arrow icon only) KEYPAD FUNCTIONS This key allows for customization of the gauge. Pressing the MENU key allows cycling through the main MENU items; UNITS, CONFIG, GRAPH, OFF, UPDAT & DAMP. Any item changed in the Menu become the new default setting(s). Revised settings are saved in the event of power loss. The A (up arrow key) or Y (down arrow key) on the keypad allows for scrolling through the MENU options to increase or decrease numeric values as required. If in the menu mode, gauge Will automatically advance to measure mode once selected MENU item has been set. This key manually turns the backlite on or off. five options are available. They include NEVER, 10 sec, 30, sec, 1 min, 5 min*. With the NEVER option, the gauge BACKLITE will remain lit whenever the gauge is in the ON mode or until the BACKLITE button is pushed again. Options, 10 sec, 30 sec, 1 min, 5 min*. allow the BACK- LITE to automatically turn-off after a selected period of time. To use the BACKLITE option: Step 1: Press the MENU key. Step 2: Press the A (up arrow key) or Y (down arrow key) until the word LITE appears. Step 3: Press ENTER. Step 4: Press the A (up arrow key) or Y (down arrow key) to select the BACKLITE option. Step 5: Press the ENTER key to finalize your choice of LITE options. 1£M008-10109-DIG New 8/03 | 2:22 PM Page 8 2/8/06 KEYPAD FUNCTIONS ~) This key allows for selecting gauge features in the ENTER | menu finalizing selection. Use of the enter key is | described throughout operating instructions. MENU OPTIONS UNITS: 12 units of measurement are available: psi, mmHG, inH20 with three temperature options: 20°C, 60°F 4°C*, mBar, inHg, ftH.0, mPa, kPa, kg/cm? and bar. Step 1: Press the MENU key until the word UNITS appears. Step 2: Press Enter. Step 3: Press the À (up arrow key) or Y (down arrow key) to select the required unit of measure. Step 4: Press ENTER to finalize the UNIT selection. Note: For inH20 range with three temperature options, press the À (up arrow key) and W (down arrow key) to select the desired temperature, then press ENTER to final- ize the UNIT selection. CONFIG: This option allows access to additional Menu options. Options include: * ENTPW or enter password (this appears as a sub-menu in the CONFIG mode if a user password has been set). * RECAL (allows for zero, span and mid-scale calibra- tion of the gauge). e ObUTN or zero key (allows for adjustment of % of range that can be zeroed), e dISAb, allows for disabling MENU options. * SETPW: This feature allows for a user defined numer- ic password. If a user password is not set, all features in the CONFIG mode will be accessible without a password. If a user password is set, all items in the CONFIG menu options are accessible with or without a user password. If a user password is programmed, it will be required to access the CONFIG menu options. “Indicates default. KEYPAD FUNCTIONS MENU FUNCTIONS How to Use Your Menu Functions To set a user password (SETPW): Step 1: Press the Menu key on the keypad Step 2: Press the A (up arrow key) or Y (down arrow key) until the word CONFIG appears. Step 3: Press Enter. The word SETPW appears on the gauge display Step 4: Press Enter. A five digit numeric password is now required. Step 5: Press the A (up arrow key) or Y (down arrow key) on the keypad to select the first digit of the password. Step 6: Press ENTER. Step 7: Repeat until the five-digit password is shown on the gauge display. Step 8: Press ENTER. Note: to erase password at any time while in the SETPW (set password) mode, press the ZERO/CLEAR key. The user will be prompted to reprogram the password once the five-digit password is entered. The gauge will display SAVE. Step 9: Press Enter to save the password setting. ENTPW: Once a user password has been established and entry into the CONFIG mode is required, the user will be prompted to ENTPW or enter password. Follow setup steps 4-8 ahove. REGAL: or recalibrate allows for zero, mid-scale, full-scale and factory default calibration of the gauge. The RECAL feature also allows for recalibration of gauges with 4-20mA output. “Indicates default. ISMO08-10109-DIG New 8/03 2/8/06 MENU FUNCTIONS To use RECAL option: Step 1: Press the Menu key on the keypad Step 2: Press the A (up arrow key) or Y (down arrow key) on the keypad until the word CONFIG appears. Step 3: Press Enter. Step 4: Enter user password if it has been programmed. Step 5: Press A (up arrow key) or Y (down arrow key) until the word RECAL appears. Step 6: Press Enter. Step 7: The gauge will now flash between INPUT and unit of measure on the lower line and .00 on the top line. Apply Zero pressure to the gauge. Step 8: Press Enter. Zero pressure is now set. Step 9: The gauge will display full-scale pressure. Apply full-scale pressure to the gauge. Step 10: Press Enter. Full-scale pressure is now set. Step 11: The gauge will now display mid-scale pressure. Apply mid-scale pressure to the gauge. Step 12: Press Enter. Mid-scale pressure is now set. (Note: For compound ranges this recalibration is zero, full-scale, mid-scale and full-vac.) FOR FACTORY CALIBRATED SETINGS: Step 13: To reinstate factory calibrated settings for zero, full-scale and mid-scale press the W (down arrow key) Menu key until the word FACT appears. Step 14: Press Enter. Factory calibration settings are now reinstated. Step 15: After zero, full-scale and/or mid-scale or factory default calibration have been set, the word SAVE appears on the gauge display. Step 16: Press Enter to finalize calibration. “Indicates default. — 10 — $ MENU FUNCTIONS Note: Calibration of Zero, mid-scale or span can be set inde- pendently of each other. For instance, if only full-scale cali- bration is required, press the W (down arrow key) until the gauge display indicates full-scale pressure. Press Enter and proceed as indicated above. Calibration of zero, midscale and full-scale is recommended when recalibrating the gauge. ZERO KEY (ObUTN): This feature allows the user to select percent of full-scale at which the gauge can be rezeroed using the Zero/Clear key on the keypad. Options include 5% full-scale*, 10% full-scale or DISAB (disable of the zero key). To use ZERO option: Step 1: Press the Menu key on the keypad. Step 2: Press the A (up arrow key) or Y (down arrow key) until the word CONFIG appears. Step 3: Press Enter. Step 4: Enter user password, if it has been programmed. Step 5: Press the A (up arrow key) or Y (down arrow key) until the word ODUTN (zero key) appears. Step 6: Press Enter. Step 7: Press the A (up arrow key) or Y (down arrow key) to select 5PCT (5% full-scale), dISAb (disable zero key) or 10PCT (10% full-scale). Step 8: Press Enter to finalize the selection. DISAB: or disable: This feature allows the user to dISAb (or disable) or ENAb (enable) items in the MENU. Some keypad keys can also be enabled or disabled. Any or all MENU items can be enabled or disabled. To use DISAB option: Step 1: Press the Menu key on the keypad. Step 2: Press the A (up arrow key) or Y (down arrow key) until the word dISAb appears. “Indicates default. — 11 — I&M008-10109-DIG New 8/03 2/8/06 2:22 PM esi MENU FUNCTIONS Step 3: press ENTER. The current setting (ENAB or dISAB) will be displayed. Step 4: Press the À (up arrow key) or Y (down arrow key) on the keypad to select a setting. Step 5: Press ENTER To finalize the setting. GRAPH: This option allows the user to change the BAR graph on the gauge display to correspond to any desired pressure within the pressure limits of the gauge. This option is useful when identifying a select portion of the full-scale range of the gauge. The default setting for the GRAPH is zero and full-scale pressure. For compound gauges, the default setting for zero is set at full-scale vacu- um. Full-scale pressure is set at the positive pressure as displayed on the gauge keypad. For gauges supplied with the 4-20mA output option, the default is 4mA equals 0% of the bar graph and 20 mA equals 100% of the bar graph. Changing the bar graph to a pressure other than 0 and 100% of range will also change the 4-20mA output to cor- respond with the new bar graph pressures for 0 and 100%. To use GRAPH option: Step 1: Press the MENU key. Step 2: Press the À (up arrow key) or W (down arrow key) on the keypad until the word until the word GRAPH appears. Step 3: Press ENTER . The gauge display will indicate the set full scale pressure range setting on the top line. The middle line indicates the bar graph at 100% of full-scale. The bottom line of the display will indicate SETFS to set the full-scale range as displayed by the bar graph and 4- 20mA. Step 4: Press the A (up arrow key) or Y (down arrow key) on the keypad to increase or decrease gauge value at 100% of range. “Indicates default. -12 — MENU FUNCTIONS Step 5: Press the ENTER key to finalize your choice. The gauge display will now display SET. After two seconds the screen will display the pressure value for 0% on the top line. The middle line indicates the bar graph at 100% of fullscale. The bottom line will display SET 0. Step 6: Press the À (up arrow key) or W (down arrow key) on the keypad to increase or decrease gauge value at 0% of range. Step 7: Press the ENTER key to finalize your choice. The new values for the bar graph and 4/20mA settings have now been saved. OFF: This option sets the amount of time before the gauge will turn itself off. Offerings are Never*, 30MIN,10MIN, 5MIN, 2 MIN. To use the OFF option: Step 1: Press the MENU key. Step 2: Press the À (up arrow key) or W (down arrow key) until the word OFF appears. Step 3: Press ENTER. Step 4: Press the À (up arrow key) or W (down arrow key) to select the desired OFF time. Step 5: Press the Enter key to finalize the OFF setting. UPDATE: This option allows for changing the rate at which pressure is updated on the display screen. This feature is useful with rapid changes in process pressure that may cause flutter of the display. Options are 100ms*, 1 sec, 500ms and 200ms, updates per second or 100ms*. since customer processes vary, update rates should be selected based on the application. To use the UPDATE option: Step 1: Press the MENU key. “Indicates default. — 13— I&M008-10109-DIG New 8/03 2/8/06 2:22 PM "ese ts MENU FUNCTIONS Step 2: Press the A (up arrow key) or Y (down arrow Key) until the word UPDATE appears. Step 3: Press Enter. Step 4: Press the A (up arrow key) or Y (down arrow key) to select an update rate. Step 5: Press ENTER to finalize the selection. DAMP or dampening: with five different options, this mode allows for taking process pressure readings and averaging them. This option is particularly useful to stabilize minor process fluctuations. The options are NONE*, AVG 8, AVG 6, AVG 4, AVG 2. Step 1: Press the MENU key until the word dAMP appears. Step 2: Press Enter Step 3: Press the A (up arrow key) or Y (down arrow key) to select a dampening option. Step 4: Press the ENTER key to finalize your Damp option. (This Menu item is only seen on units with the switch option) SWSET: Allows for setting switch setpoints. The gauge is offered with one or two SPDT switches. If (one) SPDT switch is ordered the menu option is SW1. If (two) SPDT switches are ordered, the MENU options are SW1 and SW2. Step 1: Press the MENU key. Step 2: Press the A (up arrow key) or Y (down arrow Key) on the keypad to select the switch to be set. (If two switches are present.) Step 3: Press ENTER. The top line of the gauge display will indicate pressure at 60% of the fullscale gauge range* or the most recent switch setpoint. The middle line of the dis- play will indicate a bar graph that displays the pressure position within the pressure range. The bottom line will display SETPT (blinking). “Indicates default. — 14 — MENU FUNCTIONS Note: Setpoints are limited to the full-scale pressure range of the gauge. Step 4: Press the À (Up arrow key) or W (down arrow key) on the keypad to increase or decrease switch set-point Step 5: Press the ENTER key to finalize switch setpoint. The gauge will display SET. After two seconds, the top line will indicate RETRP pressure. The bottom line will read SET. Step 6: Repeat above to set RETRP (retrip value) If the gauge is supplied with (one) setpoint, the screen will advance to the measurement mode. If (two) switches are supplied the display will advance to SW2. Repeat the aforementioned if the gauge is supplied with two switches. Notes: The bar graph will increase or decrease as any setpoint pressure is adjusted. The bar graph indicates switch setpoint position within the full-scale pressure range of the gauge. The switch setpoint unit of pressure measurement corre- sponds with the current set unit of measure of the gauge. If gauge unit of measurement is changed after switch(es) is set, switch setpoint(s) will automatically be updated to correspond with revised unit of measurement. Switch deadband is the difference between the SETPT (setpoint) and the RETRP (retrip) pressure. — 15 — | 1eM008-10109-DIG New 8/03 2/8/06 DIGITAL INDUSTRIAL GAUGE SPECIFICATIONS: aluminum Mor others on is not available with the polypropylene case, SPDT switch option(s) (XUT, or Backlite (XBL) turns on or max. max arrow Arrow thru menu items access to menu turns Arrow arrow key allows for five menu options. A (up) arrow key allows for thru menu menu 10 of measurement are three temp. options: 20°C, 60°F, 4°C*), Ft. H,0, mPa, mBar. kPa, Bar, and gauge to Zero feaure to auto gauge, 2 min., 5 min., 15 min., 30 min. 100 200 500 ms, 1 sec sec, sec, max. contact amp Switches to 100% of — 16 — 2:22 PM Page Hy DIGITAL INDUSTRIAL GAUGE RANGES: Comp. | mmHg in.Hg In. mm psi (psi) | (press.)| (press.) H20 HD mBar DISPLAY MESSAGES: ft. H20 mPa kPa Display/Problem Description Action No Battery Icon Display (applicable to gauges with batteries Gauge has <10% battery life left Replace batteries OFSET (blinking) Zero/Clear button pushed when pressure displayed is beyond set rezero pressure limit Only rezero the gauge within limits of setting in Menu Menu button disabled Gauge is in Max/Min mode Push Max/Min button until unit of measure is displayed on keypad Unit of measure selected in Menu displays N/A Resolution at full scale pressure range exceeds 50,000 counts Choose another unit of measure | can’t set the password | want 00000 is not a valid passward Select a different password | can't access items in the main Menu items that cannot be accessed have been disabled Enable item(s) in the Menu. See Menu/CONFIG and diSAb or DISABLE — 17 — | TeM00B-10109-DIG New 8/03 12/8/06 2:22 PM Page | WIRING DIAGRAM Line Powered (Type 2274) 2 conductor, 20 AWG shielded „и — Sensor Input и Battery input Keypad input DOT - Shield o Ви | Loop Powered 4-20mA (Type 2174) 2 conductor, 20 AWG shielded Red rire Black Shield E ape va 4 Ea 110 . и | - LT fa 9% y EE - Sensor Input Battery Input Keypad Input —18— WIRING DIAGRAM Line Powered/Loop Powered 4-20mA (Type 2274 XAO) 4 conductor, 20 AWG shielded tr J gs pis LE Lt. br —— Sensor Input 7 Battery input Shield Green Line Powered with (1) SPDT switch (Type 2274 XU1) 5 conductor, 22 AWG shielded не — (N.O) White er (N.C) Green | р - (COM) Brown À a" — Sensor Input vd Battery Input Keypad input vo — Shield I&M008-10109-DIG New 8/03 2/8/06 2:22 PM WIRING DIAGRAM Line Powered/Loop Powered 4-20mA with (1) SPDT switch (Type 2274 XAOU1) 7 conductor, 22 AWG shielded Red Black — (NO) Blue — (NC) Orange (COM) Brown da $ o bd no 5 uE: Battery Input Line Powered with (2) SPDT switches (Type 2274 XU2) 8 conductor, 22 AWG shielded ree (NO) White — (NC.) Green —— (COM) Brown Switch 1 (N.C, Yellow (N.C.)Blue Switch 2 (COM) Orange — Sensor Input Battery Input Keypad Input т — Shield ee Black Red — 20 — = 4 3 WIRING DIAGRAM Line Powered/Loop Powered 4-20mA with (2) SPDT switches (Type 2274 XA0U2) 10 conductor, 22 AWG shielded Red — Black TU (NO) Blue —"(NC) Orange Swiich1 | fr (COM) Brown Ss J us вн : 10 fs с E a | “| |) Ног —— (N.C) Violet ~{NO)Yellow — Switch 2 — (COM) Grey >— Sensor Input и Sensor Inp | > Battery Input Keypad Input DT ——— Shield —21— [&M008-10109-DIG New 8/03 2/8/06 2:22 PM Page GE _ WIRING DIAGRAM POWER SUPPLY SF PIN A (+) Va GAUGE — || + PINB (=) ve METER 4-20mA (seperate power supply required when switch(s) is/are ordered) Load Limitations 4-20mA Output Only A É £ 1000 - © с Ре E DA 8 750 A — > ) © © wn ® 500- o © 3 + 250- = X 0 fs я 0 10 20 30 36 Loop Supply Voltage (Vdc) Vdc MIN = 12V + [0.022A* X (RL) ] В, = Rs + Rw RL = Loop Resistance (ohms) Rs = Sense Resistance (ohms) В, = Wiring Resistance (ohms) “Includes a 10% safety factor. — 22 — — 23 — T&M008-10109-DIG New 3/02], 2/8/06 2:22 PM Page 24 | | GAUGE INSTALLATION: The Ashcroft digital industrial gauge comes standard with either À or % NPT connection. Good piping practices recommend using teflon tape or a pipe sealant on the gauge threads. Utilize a %:" (3" case), 4” (47 case) wrench on the wrench flat of the gauge to tighten the gauge to the process. NEVER TIGHTEN GAUGE THREADS BY HOLDING THE BODY OF THE GAUGE. DOING SO MAY DAMAGE THE GAUGE AND MAKE THE GAUGE INOPERABLE. PANEL MOUNTING DIMENSIONS 3" CASE HER AY CASE Battery Installation and Replacement: The Type 2074 comes standard with batteries installed. The 3” case uses qty (2) AA alka- line batteries, the 4%” case uses qty (2) C alkaline batteries. Use either Duracell MN2400, MX2400 or Energizer E92BP, X92RP AAA alkaline, non-rechargeable batteries. Batteries have a life of approximately 1500 hours (3” case). 3600 hours (4% case). Battery life is dependent on gauge usage, backlite settings and power off settings. When A the lower bar of the battery icon of the gauge display flashes, the gauge has approxi- + 7 mately 7 hours of life remaining. | To replace the batteries (3 case): To replace the batteries (4%” case): 1) Remove the single screw on the back of 1) Remove the ring on the front of the the gauge case. gauge case. 2) Hold the keypad in the palm of hand. 2) Looking at the gauge case, carefully 3) Carefully remove the two batteries from pull the front face out of the case. the holder and replace batteries. Use only — 3) Lay the gauge, face down on a flat sur- AA alkaline non-rechargeable batteries. face. To provide maximum battery life, replace 4) Carefully remove the two batteries from both batteries. the holder and replace the batteries. Use only C alkaline non-rechargeable Pipe to which gauge is attached batteries. To provide maximum battery must be properly grounded. life, replace both batteries. Asheroft Inc. Notes: 250 Main $ Stratford, oasis 45 1) Do not mix ages or brands of batteries. Tel: 203-378-8281 2) Do not replace batteries in hazardous Fax: 203-385-0602 areas. e-mail: [email protected] www.ashcroft.com © Ashcroft Inc. 2/06 14M008-10109-GBE dwg. 83B234-01 Rev. B 12/04 — 24 — <b- ">
Advertisement
Key features
- Menu-driven display
- 12 units of measurement
- Password protected calibration
- Adjustable bar graph
- 5-digit display
- Optional 4-20mA output
- Optional switching
- Optional line-power
- Meets ASME B40.7 specification
Frequently asked questions
The gauge offers 12 units of measurement: psi, mmHG, inH20 with three temperature options: 20°C, 60°F 4°C*, mBar, inHg, ftH.0, mPa, kPa, kg/cm? and bar.
Press the BACKLITE key to turn the backlite on or off.
Press the ZERO/CLR button for one second prior to gauge usage to rezero any initial zero shift. If zero shift is greater than programmed zero allowance, the gauge will display OFSET (blinking) for 1 second, then return to the measure mode.
The 3” case uses qty (2) AA alkaline batteries, the 4%” case uses qty (2) C alkaline batteries. Batteries have a life of approximately 1500 hours (3” case). 3600 hours (4% case). Battery life is dependent on gauge usage, backlite settings and power off settings.