Soma Medical SM 767A air purifier User manual
The Soma Medical SM 767A air purifier is designed to remove harmful pollutants, such as dust, smoke, bacteria, pollen and volatile organic compounds, from the air. It has different air purification modes, including high-speed, medium-speed, low-speed, mute and sleep mode. The machine has a HEPA filter, a normal temperature catalysis and purification screen and a nano photocatalytic screen which work together to purify the air. The device can be controlled via touch buttons or a remote control.
PDF
Download
Document
Advertisement
Advertisement
WARRANTY CERTIFICATE Product/Model SM767A Serial No. Date of purchase Buyer Contact telephone Seal of distributor Customer's name Tel. Mobile Zip code Customer's address Maintenance records: Terms and Conditions 1. Customer must produce the warranty card and purchase invoice when warranty service is requested during the 12 months warranty period from the date of original purchase. 2. Warranty: Soma Medical's products are warranted against defects in workmanship and material under normal use and conditions for a period of 12 months from date of original purchase. Soma Medical shall at its own discretion either repair or replace this product without charge subject to verification of the defect or malfunction. 3. Limited warranty. Warranty shall not apply to defects resulting from: (a) It does not apply to damage or loss caused by negligence, misuse, accident, improper installation or operation by unauthorised distributors/resellers (b) Defects caused by modifications or repairs other than through Soma Medical (c) Consumables, UV-C lamps are not warranted. (d) Any liability for failure of products as a result of Acts of Nature (including fire, flood, earthquake, storm, hurricane or any other natural disaster), war, invasion, act of foreign enemies, hostilities (whether war is declared or not), civil war, rebellion, revolution, insurrection, military or usurped power or confiscation, terrorist activities, nationalisation, government sanction, blockage, embargo, labour dispute, strike, lockout or interruption or failure of electricity [or telephone service]. 4. For any enquiries regarding your warranty, please contact us via [email protected]. Soma Medical Sdn Bhd (671166-M) No. 92A, Lorong Maarof Bangsar Park 59000 Kuala Lumpur, Malaysia Tel: +603- 2287 4790 Fax: +603-2287 6790 www.somamedical.net High efficiency * Energy saving * Low noise MA MEDICAL MEDICAL GERMICIDAL AIR PURIFICATION SYSTEM Model: SM 767A NNN IY YY / NOTE: Before the product is used for the very first time, please remove the plastic wrap from the filter screens. Thank you for choosing our product. Please read this manual carefully before use, and keep the manual for future references. 15 e PRODUCT DESCRIPTION e CONTENTS Name and structure of parts 1 Product description д Cleanature Inhalable particles, pathogenic microorganisms, Operation instruction 3 allergens, such as pollen, indoor pollutant, SM 767A atmospheric haze and its by-product (ozone) is Main characteristics of the product and effectively eliminated. With the release of anions, Air Purifier the air is purified. Schematic diagram for air purification----------------- 8 Product functions 11 Product specification and technical parameters----12 Working principle 12 Technical standards 12 Guideline for common troubleshooting -------------- 13 PURIFICA NON Safety notes 14 1 EUNGHIONS, ZZ Quality warranty 15 Q After- sale service network 15 Eliminates dust, mites, cigarette smoke and pollen “HEPA (MERV 16) CET TT Degerming HIGH EFFICIENCY CATALYSIS AND FILTER SCREEN PURIFICATION SCREEN Eliminates haze pollution and its by-product (ozone) Eliminates pollutants such as formaldehyde, benzene ss NANO ANION series, VOCs, etc. PHOTOCATALYTIC Eg UV-C LAMP ES GENERATOR Releases anion SCREEN NAME AND STRUCTURE OF PARTS Front frame CONE E] LCD screen : control panel — Air- out screen —— perature photocatalytic VA /V/ 77 GES) catalysis and screen APELICABIENO, OIDO EE a Back cover Cleanature SM767A air purifier is recommended for the following people and circumstances: HEPA purification High-efficiency screen Pull rope filter screen —— Receiving end SC of remote controller | NET) = > UV-C lamp = | | = A N DZ : = Air- out screen Handle : ZZ — Sensor = e \ VA ar > 3 Back LS = cover |= Base Back frame Nameplate t—_— Panel Air- in screen — Power plug CC — Manufacturer's declaration: Actual product may differ from product illustrations PATENTED APPEARANCE DESIGN The product is an IMD injection molding technology. Water and thermal transfer printing technology are adopted to the machine surface; and the product is unique and elegant GREAT PURIFICATION FUNCTION Clean Air Delivery Rate (CADR) of the SM767A model is able to reach 455 (m*/h). The combined use of HEPA, normal temperature catalysis and purification technology and photocatalysis technology improves the purifying capability significantly against pollutants, coupled with its MULTIPLE CORE TECHNICAL PATENTS The core technology of the product has been applied for multiple invention and utility model patents. HIGH EFFICIENCY AND ENERGY SAVING The brushless DC motor is equipped to the machine; the air duct design is scientific and the energy efficiency ratio is reasonably high. high disinfection function. SUPER-SILENT DESIGN It is super silent while running under sleeping mode. MICROCOMPUTER INTELLIGENT CONTROL High-tech air quality sensor, voice activation and automatic prompting for cleaning and replacement of filters have been equipped with this machine. Intelligent operation can be set to the degree of indoor air pollution, warranting good air quality. ADVANCED AIR QUALITY DISPLAY Worst Favorable CNAE GfNNNENCONOO Bad Good OEEEEEENDO] SfaONONONO) 1. Smokers (including passive smokers) 2. Those who are allergic to haze pollution 3. Those who have high requirements for healthy indoor air quality 4. Those who are sensitive to indoor pollutant 5. Pregnant women, children, old people and those who have low immune system (such as patients with chronic respiratory disease) 6. Those who live or work in places with foul or unpleasant smell 7. Places with high concentration of mobile personnel, such as private rooms of restaurant, entertainment outlets, internet cafes, hotels, meeting rooms, schools, medical institutions, sanitarians, etc. 8. Places in need of air purification, such as laboratory, computer rooms, etc. 9. Those who suffer from pollen allergy. DESCRIPTION ON OPERATION PANEL OF Automatic Display POWER KEY Power on/off of purifier Once switched on under manual mode, the machine will begin with the 4th speed. The UV-C lamp, voice and anion function will also be activated. AIR QUALITY DISPLAY GEILE] Worst SO Bad SEEN) Favorable ДЕНООООО00| Соса If back light is in 'Off mode, Air Quality Display will only be displayed for 30s when machine is activated. IN J HEPA Air Replacement/ Quality Display Cleaning . Display Display SPEED ENT GW8616B2 PURIFIER Spee à Optional UV-C Timing Display Display Display Display OPTIONAL (Cc uve =x( MODE AIR SPEED SWITCH KEY Air speed levels (1-5) can be controlled under manual mode. The actual air speed level will be displayed on the LCD screen. ANION ON/OFF KEY When the anion function is turned on, the anion icon will be displayed on the LCD screen. MODE SWITCH KEY Select the mode of operation 1) Manual mode - all functions are controlled by user 2) Automatic mode - the fan speed is automated by air quality sensor on the machine. The fan speed increases as air quality decreases. Fan speed will be displayed on the LCD screen. The air speed key will be inactive under automatic mode. 3) Night mode - The air speed will be set at mute (speed 1). All other keys, including the Voice and Back-Light functions, will be deactivated. TIMER MD NS @ VOICE ON/OFF KEY Select on or off for Voice Activation. Dynamic display screen Will show status of Voice Activation Receiving end of Remote Controller RESET HOLE Reset Keyhole: This is to re-start the clock indicating the number of hours to the next replacement of the HEPA high-efficiency filter UV-C LAMP ON/OFF KEY screens. Once the Voice Alarm sounds or the HEPA icon display lights up, the HEPA High- Select on or off for UV-C Lamp Disinfection. - Dynamic display screen will show status of the UV-C Lamp Disinfection. replaced. Efficiency Filter have clocked an accumulative 2,000 hours of air filtering and have to be Upon replacing the HEPA High- Efficiency Filters, insert a sharp pin into the Reset Keyhole to re-start the clock. This Will then deactivate the Voice Alarm and Dynamic Display. TIMING SWITCH KEY Select Timing controls to be performed in one(1) hour (1H), two(2) hours(2H), four(4) hours (4H) or eight(8) hours (8H). The timing between cycles will be displayed on the LCD screen. OH indicates the Timing control is not activated. Operation Operating Instructions Schematic Diagram Operation Operating Instructions Schematic Diagram Contents 1. Use of Remote Controller The Remote Controller comes with batteries and can be used as such. Please remove the film on the battery cover for more effective usage. To operate the Remote Controller, aim the transmitting | end of the Remote Controller to the receiving end (the display panel of the machine) at within 6-8m in distance. 4 Ensure there is no obstruction between the Remote Transmitting end of Controller and the machine. Remote Control The operating buttons on the Remote Controller How to corresponds with the Touch Keys on the product. You use the may use either to activate the functions “On/Off”, “Air Speed”, “Mode” or “Timing”. remote controller 2. Maintenance of Remote Controller If the machine is not responding to the Remote Controller, please replace the batteries, using the same model as the original batteries, and try again. The discarded batteries must be wrapped securely and discarded properly, out of reach of young children. Keep the Remote Controller away from any contact with liquids and sharp objects to prevent damage or malfunction. o (e) == a A (7) UV m m DO = Le) o г = = m pe Maintenance of Machine Sensor To ensure the Machine Sensor works efficiently, please clean it immediately if the Sensor Lens is covered with dirt. Maintain a regular cleaning of the Machine Sensor once every two (2) months. Cleaning of Machine Sensor To clean the Sensor, open the plastic cap and clean delicately the lens using cotton wool tips dipped in alcohol. Sensor Lens FN Cotton wool tips Contents How to Grip the hinges on both sides remove of the panel and pull outwards the front in the direction of arrow 1. To panel on remove panel, hoist it upwards the as indicated by arrow 2. machine Place the two rotating angles into How to the two slots at the bottom of the replace front frame as indicated by arrow the panel | 1. Snap the panel into place in the direction indicated by arrow 1. Normal temperature Catalysis and Nano Purification Photocatalytic screen Screen HEPA (MERV 16) High-Efficiency N Screen How to Placement of Filter Screens install (with reference to diagram) the filter 1. Nano Photocatalytic Screen 2. Normal temperature screen Catalysis and Purification Screen 3. HEPA (MERV 16) High-Efficiency Screen TS — Operation Contents Operating Instructions Schematic Diagram Operation . . Ns Contents Operating Instructions Schematic Diagram x E, = The replacement A. Important things to take note: of filters is 1.Do not look directly at the UV-C lamp when Pull rope completed it is turned on as this may cause eyes to hs 9 i become blurry and watery. | When installing the three Filter 2.Do not touch the UV-C lamp with your bare Ц © vo = ° Screens, ensure that ne pull rope hands. To ensure efficacy of UV-C Lamps, [ o de | lo oreach Filer screen > acing always put on gloves to handle the UV-C ge о == outwards. Install the Filter Screens Lamp = 21) | || ‚ Into the machine in the following | LP re machine is able to work as rw ow oo N — —< stipulated, always ensure that the filters are © to place 1.Nano Photocatalytic Screen, Ne J RRL О . affixed before turning on the air purifier. «< © the filter 2) Normal Temperature Catalysis 9 A © O Y ® material Purification Screen, у How to ALL 3) HEPA (MERYV 16) High-Efficiency install B. Replacement of UV-C lamp © NE FN = Screen. r —, insta Please replace the UV-C lamp once the DD | the UV-C warranty period expires for the machine Once all three Filter Screens are lamp to be effective installed, rotate the handle 3 < clockwise to lock in the filters C. Installation of UV-C lamp PD (refer to diagram). Hold on to the two ends of the light tube. IL , Insert the copper terminal at both ends into the UV-C lamp base and rotate 90° to fix Rotate the handle into place. clockwise to lock the filters in place D. Install the Nano Photocatalytic, Normal Temperature Catalysis Purification and HEPA (MERV 16) High Efficiency Filter Screens and Machine Panel in the right order. Rotate the handle clockwise to unlock orm (e o the Filter Screens | we iq Itmer © RST © ee (= Removal of UV-C lamp: Switch off the machine and allow at least How to To remove the Filter Screens, first unlock remove the handle by rotating the handle How to 15 minutes for the machine to cool down the Filter clockwise as indicated in the figure on Ne _ remove for safe handling. Remove all three (3) Screens the right. Pull rope to remove each filter. 3 the UV-C | filters in the right order. To remove UV-C Lamp, hold on to both ends of the white lam Р ceramic part of the tube and rotate 90° to remove the UV-C lamp. CLEANATURE AIR PURIFIER MAIN CHARACTERISTICS S 08 92 HEPA (MERV 16) high-efficiency filter screen: Effectively removes up to 99.99% of particles with a diameter of 0.3, which includes dust (inhalable particles), cigarette smoke, bacteria, fungal spore, pollen, dust mites and radioactive particles. Normal Temperature Catalysis and Purification Screen: High-quality catalytic activated carbon effectively removes odour from air, pollutants such as formaldehyde and other volatile organic compounds (VOCs). Nano Photocatalytic Screen: Under the action of UV rays, Nano Photocatalysts sintered under high temperature produces free electrons, which react with water vapour and oxygen to form powerful oxidizing radicals. These radicals then react with harmful volatile organic compounds in the air, VOCs like formaldehyde, benzene, methylbenzene and dimethylbenzene, breaking them down into harmless carbon dioxide and water. Microcomputer Intelligent Control: Is able to intelligently control the purification of air quality. Automatic prompter for the cleaning and replacement of HEPA (MERYV 16) High Efficiency Filter Screen can be selected. 5 LCD Display: Conveniently displays the smooth operation of the machine whenitis turnedon. Anion Generator: The anion generator produces anions larger than 3 million ions making the air naturally forest-like fresh and clean. Brushless DC Motor: The energy efficiency ratio is high based on test conducted by GB/T 18801 7 in 2008. The purification rate is level 'A' in compliance with the requirements of the U.S. Energy Star standards. 8 Super-silent Design: It is super silent while running under sleeping mode.. UV-C Lamp: Disinfection principle - UV rays radiate single-cell microorganisms (cells and virus) damaging the DNA structure, thus deactivating the proteins resulting in immediate cell death and loses the capability to reproduce. CLEANATURE AIR PURIFIER DIAGRAM FOR AIR PURIFICATION Nano (3) photocatalytic screen €» 0 Bacteria Foul smell > © Benzene Formaldehyde series The air fresh and clean Anion generator UV-C Lamp Normal temperature (2) catalysis and y @ Foul smell Peculiar smell «2 smoke en 4) Pollen #5 3 =” Dust mites Inhalable and excretion i Ozone Formaldehyde xeret particles HEPA (1) high - efficiency filter screen 3 Vitiated air Bacteria, Cigarette purification screen TT 3 le 10 PRODUCT FUNCTIONS PRODUCT SPECIFICATION AND TECHNICAL PARAMETERS . The normal temperature catalysis and purification screen eliminates harmful pollutants under normal temperature. 2. The filter efficiency of the HEPA (MERYV 16) high-efficiency filter screen is 99.97%. o © x oO a SS . Nano photocatalysis + UV-C coupled with the disinfection function continuously eliminates pollutants. . The anion generated is more than 3 million ions. . LCD full display (including air quality). . Intelligent automatic function. . The air quality sensor automatically monitors the air quality. . Timing function. 9. HEPA (MERYV 16) high-efficiency filter screen has a timer to prompt replacement/cleaning of filters. 10. There are five operation modes: ultrahigh, high, medium, low and mute. 11.Remote operation: with the assistance of voice activation function, it controls various function. 12.Touch type function. Type of power plug Domestic: 220V (two- flat pin plug) + SR 2.6m Motor specification Brushless DC motor: DC 310V Applicable power supply: AC 220/ 50 HZ Five-speed operation: Ultrahigh speed: 85W (including UV-C lamp) High speed: 65W Medium speed: 43W Low speed: 32W SCHEMATIC DIAGRAM FOR ELECTRONIC CONTROL Air Quality Sensor [ФФ | [00] ee] UV-C Lamp Motor Alarm [ФФ | .e| ee | ee | © o o Power Supply o © Control and and Drive Plate e e Display Board o o Power Connection | ee | Anion Mute: 23W Removal rate of particles of above 0.3m 99.99% Purification efficiency: grade A Removal rate of total bacterial count 99.06% Purification efficiency Formaldehyde 96.57% Purification efficiency: grade A Removal rate of gas Benzene 99.62% Purification efficiency: grade A with peculiar smell Methylbenzene 97.33% Purification efficiency: grade A Dimethylbenzene 94.74% Purification efficiency: grade A TVOC 97.07% General Environment: Moderate pollution: serious pullution: Applicable area 60-80 т? 40-60 m2 30-40 m2 Nominal power 85 W CADR 266 CFM/455 m*/h Air rate 465 m’/h Specification 450X 230 X640 mm (L XW XH) Weight 12.5KG TECHNICAL STANDARDS The complete appliance must meet the following standards and requirements: GB 4706.45- 2008, GB 4706.1 2005 For reference: GB/ T 18801 2008 11 12 GUIDELINE FORCOMMON TROUBLESHOOTING SAFETY NOTES The common problems of the product are listed below. If you cannot find the solution to your problem, kindly contact the customer service center for assistance. Problem Answer Why the product cannot work normally? >There may be some problems with the connection. Inspect if the plug is properly inserted into the socket. > The on/off button of the product may not be executed. >The front panel may not be properly secured; reinstall the front panel. > If the product still does not function after conducting the above mentioned procedure, then the product may be faulty. Why the wind wheel still does not function after connection and the power is turned on? > The front panel may not be properly secured; please reinstall the front panel. >The product may be faulty. Shut off the power supply and pull out the plug. Why fresh air is not flowing out smoothly from the air outlet? >You may have forgotten to remove the entire plastic wrap from the new filters. Completely remove them. > The air in your room may be of low quality. Under such circumstances, open the windows to ventilate the room. > The space of your room may be larger than the effective service area of the machine. Why the deodorization effect is not favourable? > The normal temperature catalysis and purification screen and nano photocatalytic screen may be ineffective due to environmental factors. If necessary, replace the temperature catalysis and purification screen. > The room where the productis placed has very poor air ventilation. Under such circumstances, open the windows to ventilate the room. > The room this machine serves exceeds the effective service area of it. Please read this manually before using the product, and keep the manual safely for future reference. > Inspect if all the filter materials provided for purification have been properly installed. > Confirm the voltage indicated at the back of the product is consistent with the local voltage. > If the power line is damaged and to avoid any mishap, it must be replaced by an authorized full-time personnel or its Repair Department authorized personnel of the manufacturer. > |f the power line or power plug is damaged, do not use the product. > The product must not be handled/operated by the disabled, mentally disordered person or children, unless supervised by an experienced adult for safety purposes. > Keep the product out of reach of children. > If the socket connecting the product has poor contact, the plug will be heated up. Ensure that the socket has proper connection. >The air inlet and outlet must not be blocked by any objects. Do not place objects at or in front of the air inlet and outlet. > Do not insert foreign objects into the air inlet and outlet. > Keep the air outlet away from any type of liquids and foreign objects. > Do not use the product in the presence of fogging, residual grease, burning incense, lighted cigarette or chemical gases. > Using this machine near liquefied petroleum gas device, heating system, furnace or stove is strictly prohibited. > Be sure to pull out the plug after use and before cleaning the product. >Do not use the product in the room with high temperature change, as it may cause internal condensation. > To prevent interference, ensure that the product is placed at least 2m away from any electrical appliance using radio wave (like TV, radio and wireless control clock). > Safety device is equipped. The machine will not turn on if the panel is not installed correctly. > The product can only be used indoors under normal running conditions. > Do not use the product in humid or high temperature environment (such as bathroom or kitchen). ANNEXES Why is there an abnormal sound during the operation of the product? >The air inlet or outlet may be blocked by foreign objects. Remove all foreign objects from the air inlet and outlet. > The product may be faulty. Contact the local customer service center for assistance. HEPA high - efficiency filter screen 1 (installed into the machine) Normal temperature catalysis and . . purification screen 1 (installed into the machine) Nano photocatalytic screen 1 (installed into the machine) Remote controller and battery 1 (battery installed) User manual (with Quality warranty card) 1 copy 13 Conformity certificate 1 copy 14 ">
Advertisement
Key features
- HEPA filter
- Normal Temperature Catalysis and Purification Screen
- Nano Photocatalytic Screen
- UV-C Lamp
- Anion Generator
- Microcomputer Intelligent Control
- Remote control
- Voice activation
- LCD display
- 5 speeds
Frequently asked questions
The Soma Medical SM 767A air purifier uses three filters: a HEPA filter, a normal temperature catalysis and purification screen and a nano photocatalytic screen.
To clean the air purifier, first unplug it from the power outlet. Then, remove the front panel and clean the filters. You can use a vacuum cleaner to remove dust from the filters, or you can wash them with water and let them dry completely. Once the filters are clean, replace the front panel and plug the machine back in.
The HEPA filter should be replaced every 2,000 hours of use. The other filters, normal temperature catalysis and purification screen and nano photocatalytic screen, should be replaced as needed.
To use the remote control, point the remote at the air purifier and press the desired button. The remote control has buttons for power, air speed, mode, timer and UV-C lamp.