Product Specification
Item
Specification
Voltage
Lock Relay
Environmental
Temperature
Relative Humidity
12VDC ±10%, Current 1.2A
12VDC/2A
working: 0°C~45°C;
storage: -10°C~55°C
working: 40%~90% RH,
storage: 20%~90% RH
500
Public PIN: 1, Private PIN: 500
ID model: 125KHz
IC model: 13.56MHz
ID model: EM or compatible
IC model Mifarel or compatible
ID model: 5 – 15cm
IC model: 3 – 5 cm
Relay output or level output
One interface
One interface
One interface
One level output
One weigand26 interface (only applies to certain
models)
Card Capacity
PIN Capacity
Internal Reader Frequency
Proximity Card
Card Reading Distance
Lock Interface
Exit Button
Bell
Door Contact
Alarm Interface
External Reader
Factory Defaults
Item
Value
Programming PIN
Door open mode
Private PIN
Door open time
990101
card or public PIN (1234)
0000
3 seconds
RFID Card Access Control Unit
Operating Instructions
Anti-break alarm
Door contact alarm
Lock status
Alarm delay
Modify private PIN
disabled
disabled
disabled
0 seconds
disabled
The LED and Buzzer
Normal Mode
Valid command
Invalid command
short beep
long beep
Programming mode (green LED on)
Valid command
Invalid command
two short beeps
Three beeps
Cancel Command
Press the [*] key to cancel command.
Functions and Setup
Enter the programming mode
Press [*]+[6-digit pin] (default is 990101)
Modify the programming PIN
Press [0]+[the 6-digit PIN]+[confirm the new 6-digit PIN]
Enrol card
Press [5]
+[3-digit index code](2 beeps)
+[card1](beep, 2 beeps)
+[card2](beep, 2 beeps)
+…
+[cardn](beep, 2 beeps)
+[*](2 beeps)
1
3-digit index code range from 001 – 500. Card can be deleted by this code.
When enrolling multiple cards, every card index code will be calculated in order.
For example, card one’s index code is 015, card two’s will be 016.
The default private PIN for each card is 0000.
PINs
The PIN in “Card or PIN” mode is either the public PIN or private PIN (at most
500).
Disable changing private PIN
Press [1]+[2](2 beeps)
Delete Card
Delete by index code
press [7]
+[3-digit code1](2 beeps)
+[3-digit code2](2 beeps)
+…
+[3-digit coden](2 beeps)
+[*](2 beeps)
Delete by presenting card
Press [7]
+[Present card1](beep, 2 beeps)
+[Present card2](beep, 2 beeps)
+…
+[Present cardn](beep, 2 beeps)
+[*](2 beeps)
Delete all cards – please restore the factory default.
The private PIN will be deleted when the card is deleted.
Exit programming mode
Press [*](2 beeps)
Enable changing private PIN
Press [1]+[3](2 beeps)
Change private PIN
Press [#](2 beeps)
+[present card](beep, 2 beeps)
+[4-digit old PIN](2 beeps)
+[4-digit new PIN]
+[confirm the new PIN](2 beeps)
Change public PIN
Press [3]+[4-digit PIN](default 1234)
When the public or private PIN is 0000, the PIN is void in “Card or PIN” mode.
Change door open time
Press [2]+[TT]
TT is the time interval in seconds, For example, if the door open time is 3
seconds, then TT=03.
Anti-break
Setup door open mode
Card or PIN mode: press [1][0](2 beeps)
Card + private PIN mode: press [1][1](2 beeps)
Disable anti-break: press [4]+[0]
Enable anti-break: press [4]+[1]
Door contact sensor
Disable door contact sensor: press [6]+[0]
Enable door contact sensor: press [6]+[1]
RFID Card Access Control Unit
Operating Instructions
2
Door sensor alarm
Frequently asked questions
Disable alarm: press [8]+[0]
Enable alarm: press [8]+[1]
After turning on this function, the controller will give off a continuous long beep
when the door is not closed after normal opening, or the door is not opened
through the controller.
Symptom
Possible solutions
After the lock is opened, there are 8
short beeps
The card reading distance is short,
or the card cannot be read.
The controller needs higher voltage –
check power supply
If the controller is on a metal surface, it
should be moved to another place.
Check the power supply
It’s in card+PIN mode
[#] key is pressed, wait for 5 seconds to
present the card.
Check if the door sensor is in alarm status
Disable the door sensor alarm
Other keys are pressed before the [*] key.
Keep on pressing [*] key after long beep,
then enter the programming mode again.
Other keys are pressed before pressing
the [*] key after long beep, then press the
[*] key again.
The controller has full card capacity
This index code is in use, select another
index code.
This card is in use.
Alarm delay time
Press [8][2]+[TT]
TT is the time interval in seconds. For example, if the delay time is 3 seconds,
then TT=03.
When the door is locked TT seconds, if the door contact sensor is in alarm state,
the controller is in alarm mode. This function should be used when the door
sensor alarm is on.
Restore factory default
Press [8][6]. There will be 2 beeps, 3 beeps, and after 5 seconds a further 3
beeps, then the factory defaults are restored.
After reading card there are 3 beeps
and lock is not open
The enrolled card cannot open the
door
Press [*]+[programming PIN] there
is long beep and cannot enter the
programming mode.
Press [#] key, there is a long beep,
the private PIN cannot be changed
Press [5], there are 3 beeps
Press [5]+[index code], 3 beeps
User’s instructions
Card or PIN mode
The PINs should be entered in 2 seconds.
Press [*] key to cancel PIN input.
Press [5]+[index code], 2 beeps,
+[present card](3 beeps)
The controller exits programming
mode
Card + Private PIN mode
[Reading card]+[enter 4-digit PIN] to open
Press [*] key to cancel PIN input
Wiring
Reset Programming PIN
Short the J2 on the controller to reset the programming PIN to factory default.
With normal power supply
DOOR
RFID Card Access Control Unit
In programming mode, if there is no input
for 20 seconds, the controller exits
programming mode automatically.
Operating Instructions
To door contact
3
The other end to DGND
DGND
POENSW
PUSH/NO
NC
GND
+12VDC
BELL
BELL
JP3
JP2
To exit button
To GND of the fail-safe lock
To GND of the fail-open lock
To GND of the power supply
To the +12v of power supply
To door bell
To door bell
Short JP3
Short 1,2
The other end to DGND
The other end of the lock to +12vDC
The other end of the lock to +12vDC
With access control power supply
DOOR
DGND
POENSW
PUSH/NO
NC
GND
+12vDC
BELL
BELL
JP3
JP2
To door contact
The other end to DGND
To exit button
To PUSH on power
supply
The other end to DGND
The lock should be wired to power supply’s
NC and ground
To GND of the power
supply
To the +12v of power
supply
To door bell
To door bell
Do NOT short JP3
Short 2,3
RFID Card Access Control Unit