baybrook - Life Time Public BIDsite

2902 CORPORATE PLACE CHANHASSEN, MN
55317
B4
CONSULTANT
TECHNOLOGY SHEET LIST
C
##
C
C
C
AP-##
W
EM
SS
#XX
TV
#XX
TV1
#XX
TV2
#XX
TV3
#XX
TV4
#XX
TV5
#XX
#XX
#XX
#XX
#XX
TV
TV1
TV2
TV3
TV4
FM #
SAT
S
S
S
S
DEVICE WIRED BY
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
SECURITY CAMERA - CEILING MOUNT - XX DENOTES CAMERA #
(SEE CAMERA SCHEDULE FOR MORE INFORMATION).
2-GANG J-BOX WITH SINGLE-GANG MUDRING &
TILE BRIDGE, MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK CCTV PATCH PANEL. TERMINATE TO BISCUIT STYLE JACK ABOVE CEILING WITH 20'
SERVICE COIL.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
(1) CAT6 WITH 1 PORT AT 18" AFF
UNLESS OTHERWISE NOTED
2-GANG J-BOX WITH SINGLE-GANG MUDRING
PROVIDE (1) CAT6 TO NEAREST DATA RACK PATCH PANEL. PROVIDE 10' SERVICE COIL AT CONDUIT STUB OUT.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
(2) CAT6 DATA WITH 1 PORT AT 18" AFF
UNLESS OTHERWISE NOTED
2-GANG J-BOX WITH SINGLE-GANG MUDRING
PROVIDE (2) CAT6 TO NEAREST DATA RACK PATCH PANEL. PROVIDE 10' SERVICE COIL AT CONDUIT STUB OUT.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
(1) CAT6 DATA WITH 1 PORT, CEILING MOUNTED
2-GANG J-BOX WITH SINGLE-GANG MUDRING & TILE BRIDGE
PROVIDE (1) CAT6 TO NEAREST DATA RACK PATCH PANEL. PROVIDE 10' SERVICE COIL AT CONDUIT STUB OUT.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
(1) CAT6 DATA WITH 1 PORT, CEILING MOUNTED
2-GANG J-BOX WITH SINGLE-GANG MUDRING & TILE BRIDGE
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK CCTV PATCH PANEL. TERMINATE TO BISCUIT STYLE JACK ABOVE CEILING WITH 20'
SERVICE COIL.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
(1) CAT6 DATA WITH 1 PORT AT 54" AFF
2-GANG J-BOX WITH SINGLE-GANG MUDRING
PROVIDE (1) CAT6 TO NEAREST DATA RACK PATCH PANEL. PROVIDE 10' SERVICE COIL AT CONDUIT STUB OUT.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
(1) CAT6 DATA WITH 1 PORT AT 54" AFF
2-GANG J-BOX WITH SINGLE-GANG MUDRING
(STAINLESS STEEL)
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WALL MOUNT TELEVISION OUTLET AT 18" AFF, UNLESS OTHERWISE NOTED.
BLACK SINGLE GANG 4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING,
MINIMUM 3" DEEP BOX
PROVIDE (1) COAX MDF TERMINATED IN WALLPLATE BOOX AND CONDUIT PROVIIDE BY ELECTRICAL CONTRACTOR. SEE VIDEO RISER
DIAGRAM FOR WIRE TYPE AND CONFIGURATION.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WALL MOUNT TELEVISION OUTLET AT 18" AFF, UNLESS OTHERWISE NOTED.
BLACK SINGLE GANG 4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING,
MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN MDF RACK PATCH PANEL FOR VIDEO.
PROVIDE (1) COAX MDF TERMINATED IN WALLPLATE BOX AND CONDUIT PROVIIDE BY ELECTRICAL CONTRACTOR.
SEE VIDEO RISER DIAGRAM FOR WIRE TYPE AND CONFIGURATION.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WALL MOUNT TELEVISION OUTLET AT 18" AFF, UNLESS OTHERWISE NOTED.
BLACK SINGLE GANG 4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING,
MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK PATCH PANEL FOR DATA.
PROVIDE (1) CAT6 TERMINATED IN MDF VIDEO RACK PATCH PANEL FOR VIDEO.
PROVIDE (1) COAX MDF TERMINATED IN WALLPLATE BOX AND CONDUIT PROVIIDE BY ELECTRICAL
CONTRACTOR. SEE VIDEO RISER DIAGRAM FOR WIRE TYPE AND CONFIGURATION.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WALL MOUNT TELEVISION OUTLET AT 18" AFF, UNLESS OTHERWISE NOTED.
BLACK SINGLE GANG 4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING,
MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK PATCH PANEL FOR DATA.
PROVIDE (1) CAT6 TERMINATED IN MDF VIDEO RACK PATCH PANEL FOR VIDEO.
PROVIDE 15' SERVICE COIL.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WALL MOUNT TELEVISION OUTLET AT 18" AFF, UNLESS OTHERWISE NOTED.
BLACK SINGLE GANG 4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING,
MINIMUM 3" DEEP BOX
PROVIDE (2) CAT6 TO NEAREST DATA RACK PATCH PANEL.
PROVIDE (1) CAT6 TO NEARBY AV CABINET WITHIN STUDIO.
TERMINATE TO WALLPLATE BEHIND TV.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
TRENCH DUCT / FLOOR BOX / POKE-THROUGH MOUNT TELEVISION/DATA
OUTLET. #XX DENOTES TELEVISION NUMBER.
FLOOR BOX ACTIVATION
PROVIDE (1) CAT6 TERMINATED IN MDF RACK PATCH PANEL FOR VIDEO. PROVIDE (1) COAX MDF TERMINATED IN TRENCHDUCT / FLOORBOX.
PROVIDE (1) BLACK CAT6 JUMPER AND (1) BLACK COAX JUMPER CABLE HANGING OUT OF BOX FOR CONNECTIONS TO FITNESS EQUIPMENT.
LENGTHS VARY PER FITNESS EQUIPMENT. CABLES MUST BE INSTALLED PRIOR TO FITNESS EQUIPMENT INSTALLATION.
TRENCH DUCT / FLOOR BOX /
POKE-THROUGH
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
PROVIDE (1) COAX MDF TERMINATED IN WALLPLATE BOOX AND CONDUIT PROVIIDE BY ELECTRICAL
CONTRACTOR. SEE VIDEO RISER DIAGRAM FOR WIRE TYPE AND CONFIGURATION.
3/4" CONDUIT TO ACCESSIBLE CEILING
CEILING MOUNT TELEVISION OUTLET. WHITE SINGLE GANG
4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING &
TILE BRIDGE, MINIMUM 3" DEEP BOX
CEILING MOUNT TELEVISION OUTLET. WHITE SINGLE GANG
4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING &
TILE BRIDGE, MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN MDF RACK PATCH PANEL FOR VIDEO.
PROVIDE (1) COAX MDF TERMINATED IN WALLPLATE BOX AND CONDUIT PROVIIDE BY ELECTRICAL
CONTRACTOR. SE VIDEO RISER DIAGRAM FOR WIRE TYPE AND CONFIGURATION.
3/4" CONDUIT TO ACCESSIBLE CEILING
CEILING MOUNT TELEVISION OUTLET. WHITE SINGLE GANG
4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING &
TILE BRIDGE, MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK PATCH PANEL FOR DATA. PROVIDE (1) CAT6 TERMINATED IN MDF VIDEO RACK
PATCH PANEL FOR VIDEO. PROVIDE (1) COAX MDF TERMINATED IN WALLPLATE BOX AND CONDUIT PROVIIDE BY ELECTRICAL CONTRACTOR.
SEE VIDEO RISER DIAGRAM FOR WIRE TYPE AND CONFIGURATION.
3/4" CONDUIT TO ACCESSIBLE CEILING
CEILING MOUNT TELEVISION OUTLET. WHITE SINGLE GANG
4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING &
TILE BRIDGE, MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK PATCH PANEL FOR DATA.
PROVIDE (1) CAT6 TERMINATED IN MDF VIDEO RACK PATCH PANEL FOR VIDEO.
PROVIDE 15' SERVICE COIL.
3/4" CONDUIT TO ACCESSIBLE CEILING
CEILING MOUNT TELEVISION OUTLET. WHITE SINGLE GANG
4-PORT FACEPLATE. PROVIDE BLANK INSERTS WHEN
NECESSARY. X## DENOTES TELEVISION NUMBER.
2-GANG J-BOX WITH SINGLE-GANG MUDRING &
TILE BRIDGE, MINIMUM 3" DEEP BOX
PROVIDE (2) CAT6 TO NEAREST DATA RACK PATCH PANEL.
PROVIDE (1) CAT6 TO NEARBY AV CABINET WITHIN STUDIO.
TERMINATE TO WALLPLATE BEHIND TV.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 26 CONTRACTOR
DIV 26 CONTRACTOR
DIV 26 CONTRACTOR
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
DIV 27 CONTRACTOR
DIV 27 CONTRACTOR
DIV 27 CONTRACTOR
DIV 27 CONTRACTOR
FM TRANSMITTER LOCATED BEHIND TV. DIPOLE ANTENNA
MOUNTED ABOVE SOFFIT WITH CUSTOM BRACKET
NO ROUGH-IN REQUIREMENTS
SEE VIDEO RISER DIAGRAM FOR WIRE TYPE AND CONFIGURATION.
NO CONDUIT REQUIREMENTS
--
DIV 27 CONTRACTOR
SATILITE CONNECTION
PROVIDE WEATHER BOOT ON 2" CONDUIT STUB
THROUGHS
PROVIDE (7) OUTDOOR RATED RG6 COAX CABLES FROM MDF TO ROOF. LEAVE 25' EXCES CABLLE
COILED. TERMINATE BOTH SIDES WITH F-STYLE CONNECTORS. PLACE DI-ELECTRIC GREASE INSIDE
CONNECTORS WHILE TERMINATING.
(2) 2" CONTINUOUS EMT FROM MDF TO
ROOF.
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
FINISH WITH BLANK COVERPLATE
PROVIDE (1) 16-2 SPEAKER CABLE FROM SPEAKER CHAIN TO AUDIO RACK IN MDF. LEAVE 15' COILDED
FOR SPEAKER INSTALLER TO TERMINATE. LEAVE 20' NEAR AUDIO RACK IN MDF. SPEAKER INSTALLER
TO CALCULATE FULL ZONE WATTAGE. CALCULATE MAXIMUM SPEAKER WATTAGE PER SPEAKER
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
PROVIDE (1) 16-2 SPEAKER CABLE FROM SPEAKER CHAIN TO AUDIO RACK IN MDF. LEAVE 15' COILDED
FOR SPEAKER INSTALLER TO TERMINATE. LEAVE 20' NEAR AUDIO RACK IN MDF. SPEAKER INSTALLER
TO CALCULATE FULL ZONE WATTAGE. CALCULATE MAXIMUM SPEAKER WATTAGE PER SPEAKER
3/4" CONDUIT TO ACCESSIBLE CEILING
2-GANG J-BOX WITH BLANK COVERPLATE.
MINIMUM 3" DEEP BOX.
PROVIDE FIELD SOLDERED / TERMINATED PLENUM RATED SHIELDED 22 AWG MIC / LINE CABLE
PROVIDE WIRE FROM SUB TO MDF AUDIO WALL FIELD. TERMINATE TO XLR MALE CONNECTOR.
NO CONDUIT REQUIREMENTS
FLOOR SUB WOOFER SPEAKER
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (1) STRANDED 22/2 WITH DRAIN TERMINATED TO XLR STYLE MALE WALLPLATE.
WIRE SHALL BE PULLED TO LOCATION SHOWN PER PLAN.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
LOUD SPEAKER MOUNTED TO SOFFIT. (1) STRANDED 22/2
SHIELDED WITH DRAIN TERMINATED TO XLR STYLE WALLPLATE
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (1) STRANDED 22/2 WITH DRAIN TERMINATED TO XLR STYLE MALE WALLPLATE.
WIRE SHALL BE PULLED TO LOCATION SHOWN PER PLAN.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
PENDANT HANGING SPEAKER
NONE
NONE
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
LANDSCAPE BURIAL SPEAKER
REFERENCE PRINTS FOR ROUGH-IN REQUIREMENTS
REFERENCE PRINTS FOR ROUGH-IN REQUIREMENTS
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
8 OHM IN-CEILING SPEAKER WITH INDEPENDENT HOMERUN (HR)
NONE
NONE
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
PROVIDE (1) 16-2 SPEAKER CABLE FROM SPEAKER CHAIN TO AUDIO RACK IN MDF. LEAVE 15' COILDED FOR SPEAKER INSTALLER TO
TERMINATE. LEAVE 20' NEAR AUDIO RACK IN MDF. SPEAKER INSTALLER TO CALCULATE FULL ZONE WATTAGE. CALCULATE MAXIMUM
SPEAKER WATTAGE PER SPEAKER
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
SUB WOOFER SPEAKER
SUB
SUB FL
LOUD
DEVICE FURNISHED BY
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK CCTV PATCH PANEL. PROVIDE 10' SERVICE COIL AT CONDUIT STUB OUT.
NO ROUGH-IN REQUIREMENTS
S
S
CONDUIT REQUIREMENTS
2-GANG J-BOX WITH SINGLE-GANG MUDRING,
MINIMUM 3" DEEP BOX
CEILING MOUNT SPEAKER
S
WIRING REQUIREMENTS
SECURITY CAMERA - WALL MOUNT - XX DENOTES CAMERA #
(SEE CAMERA SCHEDULE FOR MORE INFORMATION).
WALL MOUNT SPEAKER/OUTLET
S
ROUGH-IN REQUIREMENTS
--
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
DIV 27 CONTRACTOR
DIV 27 CONTRACTOR
PEN
LAND
HR
S
WALL MOUNT HORN
DIV 27 CONTRACTOR
A
WALL MOUNT AUDIO SYSTEM OUTLET AT 18" AFF,
UNLESS OTHERWISE NOTED
2-GANG J-BOX WITH 2-GANG MUDRING.
MINIMUM 3" DEEP BOX
WALL PLATE FOR LINE LEVEL AUDIO TV SPEAKERS IN ROOM. PROVIDE FIELD SOLDERED / TERMINATED PLENUM RATED SHIELDED 22 AWG
MIC / LINE CABLE. PROVIDE HEAT SHRINK BOOTS AT ALL TERMINATIONS.
1" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
A1
WALL MOUNT AUDIO SYSTEM OUTLET AT 18" AFF,
UNLESS OTHERWISE NOTED
3-GANG J-BOX WITH 3-GANG MUDRING.
MINIMUM 3" DEEP BOX
WALL PLATE FOR LINE LEVEL AUDIO TO SPEAKERS IN ROOM AND HDBaseT CONNECTIONS TO DISPLAY DEVICES. PROVIDE 2-GANG PREPUNCHED STAINLESS PLATE WITH (2) XLR JACKS FOR AUDIO CABLING AND (2) CAT6 PASS THROUGH JACKS FOR VIDEO CABLING. PROVIDE
FIELD SOLDERED / TERMINATED PLENUM RATED SHIELDED 22 AWG MIC / LINE CABLE. PROVIDE HEAT SHRINK BOOTS AT ALL
TERMINATIONS AND SHIELDED CAT6 CABLING TO PLATE AT DISPLAY DEVICES.
(2) 1" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
A2
A3
WALL MOUNT AUDIO SYSTEM OUTLET AT 18" AFF,
UNLESS OTHERWISE NOTED
3-GANG J-BOX WITH 3-GANG MUDRING.
MINIMUM 3" DEEP BOX
GROMMETED WALL PLATE FOR LINE LEVEL AUDIO TO SPEAKERS IN ROOM AND DATA TO ZONE CONTROLLER IN ROOM. PROVIDE FIELD
SOLDERED / TERMINATED PLENUM RATED SHIELDED 22 AWG MIC / LINE CABLE. PROVIDE HEAT SHRINK BOOTS AT ALL TERMINATIONS.
(1) 1" CONDUIT TO ACCESSIBLE CEILING
& (1) 1" CONDUIT TO ZONE CONTROL
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
CUSTOM 5-GANG WALLPLATE PROVIDED BY OWNER
5-GANG J-BOX WITH 5-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (4) 22/2 FROM LOCAL CABINET WITHIN STUDIO. TERMINATED TO OWNER PROVIDED 5-GANG WALLPLATE. PROVIDE (2) NETWORK DATA
CABLES TO NEAREST IDF/MDF DATA PATCH PANEL. PROVIDE 10' SERVICE COIL IN BOTH LOCAL CABINET WITHIN STUDIO AND IDF/MDF RACK.
(2) 3/4" CONDUIT TO ACCESSIBLE
CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
A4
AV SYSTEM CONTROLLER BOX AT 18" AFF,
UNLESS OTHERWISE NOTED
3-GANG J-BOX WITH 3-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (5) CAT6 CABLES FROM PROJECTOR LOCATION IN PLENUM RATED BOX DOWN TO JUNCTION BOX. INSIDE JUNCTION BOX TERMINATE
WITH MOD STYLE RJ45 PLUGS. INSIDE PLENUM BOX TERMINATE TO BISCUIT STYLE JACKS.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
A5
AUDIO EXTENSION FOR REMOTE AUDIO SYSTEM AT 18" AFF,
UNLESS OTHERWISE NOTED.
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (2) CAT6 TO AUDIO RACK IN MDF. TERMINATE TO WALLPLATE AT "A5" LOCATION. TERMINATE TO PATCH PANEL IN AUDIO RACK AND
LABEL PER INPUT DEVICE.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
Z
WALL MOUNT ZONE CONTROL OUTLET AT 46' AFF,
UNLESS OTHERWISE NOTED.
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 TERMINATED IN NEAREST DATA RACK PATCH PANEL FOR DATA. TERMINATE WITH KEYSTONE JACK INSIDE BOX. WALLPLATE
AND CONDUIT PROVIDED BY ELECTRIICAL CONTRACTOR.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
Z1
WALL MOUNT ZONE CONTROL OUTLET AT 46' AFF,
UNLESS OTHERWISE NOTED.
2-GANG J-BOX WITH 2-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (2) CAT6 TERMINATED IN NEAREST DATA RACK PATCH PANEL FOR DATA. TERMINATE WITH KEYSTONE JACK INSIDE BOX. WALLPLATE
AND CONDUIT PROVIDED BY ELECTRIICAL CONTRACTOR.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
Z2
DUAL GANG WALL CONTROLLER FOR INDEPENDANT AV CONTROL
SYSTEM AT 46" AFF, UNLESS OTHERWISE NOTED.
2-GANG J-BOX WITH 2-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (1) CAT6 CABLE FROM PROJECTOR LOCATION IN PLENUM RATED BOX DOWN TO JUNCTION BOX. INSIDE JUCTION BOX TERMINATE WITH
MOD STYLE RJ45 PLUG . INSIDE PLENUM BOX TERMINATE TO BISCUIT STYLE JACK.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
Z3
DUAL GANG WALL CONTROLLER FOR INDEPENDANT AUDIO SYSTEM
CONTROL SYSTEM AT 46" AFF, UNLESS OTHERWISE NOTED.
2-GANG J-BOX WITH 2-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (2) CAT6 CABLE FROM LOCAL AUDIO CABINET LOCATION IN PLENUM. INSIDE JUCTION BOX TERMINATE WITH MOD STYLE RJ45 PLUG .
INSIDE CABINET TERMINATE TO WALLPLATE.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
M
WALL MOUNT MICOROPHONE OUTLET AT 18' AFF,
UNLESS OTHERWISE NOTED.
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE FIELD SOLDERED / TERMINATED PLENUM RATED SHIELDED 22 AWG MIC / LINE CABLE PROVIDE WIRE FROM AMBIENT NOISE
MICROPHONE TO MDF AUDIO WALL FIELD.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
V
WALL MOUNT VOLUME CONTROL OUTLET AT 46' AFF,
UNLESS OTHERWISE NOTED.
2-GANG J-BOX WITH SINGLE-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (1) RG58 MICROPHONE ANTENNA CABLING. TERMINATE BOTH ENDS WITH BNC. LEAVE 10' COILED IN RACK AND 10' SERVICE COIL
ABOVE CEILING.
3/4" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
CEILING MOUNT AMBIENT NOISE MICROPHONE
4x4x6 SURFACE MOUNT BOX WITH BLANK
COVERPLATE.
NONE
NO CONDUIT REQUIREMENTS
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WIRELESS MICROPHONE REMOTE ANTENNA
NONE
NONE
NO CONDUIT REQUIREMENTS
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
DOORBELL AT 46' AFF,
UNLESS OTHERWISE NOTED.
PROVIDE LOW VOLTAGE CABLING PATHWAY THROUGH CURTAIN WALL
SYSTEM. DRILL 3/4" HOLE AT 46" AFF, UNLESS OTHERWISE NOTED.
PROVIDE (2) 18-2 BELL WIRE TO TONE GENERATOR IN MDF.
1/2" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WALL MOUNT PROJECTOR
2-GANG J-BOX WITH 2-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (2) DATA CABLES TO NEAREST DATA CLOSET. TERMINATE TO A/V PATCH PANEL IN NETWORK RACK. PROVIDE (1) SHIELDED CAT6 CABLE
FOR LOCAL VIDEO (SHIELDED CAT6) FROM PROJECTOR TO WALLPLATE PROVIDED BY AV INSTALLER.
(2) 1" CONDUIT TO ACCESSIBLE CEILING
BY OTHERS
DIV 27 CONTRACTOR
CEILING MOUNT PROJECTOR
UNIVERSAL PROJECTOR CEILING MOUNT KIT PROVIDED BY OWNER.
ELECTRICAL OUTLET MOUNTED INSIDE BOX ABOVE CEILING.
PROVIDE (2) DATA CABLES TO NEAREST DATA CLOSET. TERMINATE TO A/V PATCH PANEL IN NETWORK RACK. PROVIDE (1) SHIELDED CAT6 CABLE
FOR LOCAL VIDEO (SHIELDED CAT6) FROM PROJECTOR TO WALLPLATE PROVIDED BY AV INSTALLER. IN CEILING TERMINATE TO BISCUIT STYLE
CONNECTION INSIDE PLENUM RAATED BOX PROVIDED BY A/V INSTALLER.
NO CONDUIT REQUIREMENTS
BY OTHERS
DIV 27 CONTRACTOR
WALL MOUNT DIGITAL SIGNAGE PROJECTOR
2-GANG J-BOX WITH 2-GANG MUDRING.
MINIMUM 3" DEEP BOX
PROVIDE (2) DATA CABLES TO NEAREST DATA CLOSET. TERMINATE TO A/V PATCH PANEL IN NETWORK RACK. PROVIDE BISCUIT IN CEILING SPACE
HIDDEN FROM VIEW
(2) 1" CONDUIT TO ACCESSIBLE CEILING
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
CEILING MOUNT DIGITAL SIGNAGE PROJECTOR
UNIVERSAL PROJECTOR CEILING MOUNT KIT PROVIDED BY OWNER.
ELECTRICAL OUTLET MOUNTED INSIDE BOX ABOVE CEILING.
PROVIDE (2) DATA CABLES TO NEAREST DATA CLOSET. TERMINATE TO A/V PATCH PANEL IN NETWORK RACK. PROVIDE BISCUIT IN CEILING SPACE
HIDDEN FROM VIEW
NO CONDUIT REQUIREMENTS
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WK
WALL MOUNT SPECIAL EFFECTS LIGHTING (PROVIDED BY OWNER)
2-GANG SPLIT BOX AS SPECIFIED ON PLAN
PROVIDE 110 OHM DMX CONTROL CABLE, BELDEN 1801B. PULL FROM 5-GAMNG BOX NEAR PLATFORM TO FIRST LIGHT LOCATION; DAISY CHAIN
BETWEEN FIXTURES AS SHOWN ON PLAN.
NO CONDUIT REQUIREMENTS
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WK
CEILING MOUNT SPECIAL EFFECTS LIGHTING (PROVIDED BY OWNER)
2-GANG SPLIT BOX AS SPECIFIED ON PLAN
PROVIDE 110 OHM DMX CONTROL CABLE, BELDEN 1801B. PULL FROM 5-GAMNG BOX NEAR PLATFORM TO FIRST LIGHT LOCATION; DAISY CHAIN
BETWEEN FIXTURES AS SHOWN ON PLAN.
NO CONDUIT REQUIREMENTS
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
WALL MOUNT ROOM SCHEDULE
2-GANG RECESSED BACK BOX. ARLINGTON #TVBS505. BOX ALSO
HOUSES ELECTRICAL OUTLET. REFER TO POWER PLANS
PROVIDE (2) DATA CABLES TO NEAREST DATA RACK PATCH PANEL. TERMINATE WITH KEYSTONE CONNECTOR TO WALLPLATE. CONDUIT / BACKBOX
PROVIDED BY ELECTRICAL CONTRACTOR.
3/4" CONDUIT
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
FLOOR MOUNT ROOM SCHEDULE
FLOOR BOX
PROVIDE (2) DATA CABLES TO NEAREST DATA RACK PATCH PANEL. TERMINATE WITH JACKS INSIDEE PODIUM BASE. CONDUIT PROVIDED BY
ELECTRICAL CONTRACTOR. CABLING FROM BENEATH.
3/4" CONDUIT
DIV 26 CONTRACTOR
DIV 27 CONTRACTOR
M
MA
P
P
P1
P1
RS
RS
ELECTRICAL ABBREVIATIONS
A, AMP
AMPERES
MC
MOMENTARY CONTACT
AA
AUDIBLE ALARM
MCB
MAIN CIRCUIT BREAKER
AC
ABOVE COUNTER
MLO
MAIN LUG ONLY
ADD
ADDENDUM
MRS
MOTOR RATED SWITCH
AFC
AVAILABLE FAULT CURRENT
MSB
MAIN SWITCHBOARD
AFCI
ARC FAULT CIRCUIT INTERRUPTER
MT
EMPTY
AFF
ABOVE FINISHED FLOOR
NC
NORMALLY CLOSED
AHU
AIR HANDLING UNIT
NEC
NATIONAL ELECTRICAL CODE
AL
ALUMINUM
NIC
NOT IN CONTRACT
ANT
ANTENNA
NO
NORMALLY OPEN
ATS
AUTOMATIC TRANSFER SWITCH
NTS
NOT TO SCALE
BAS
BUILDING AUTOMATION SYSTEM
OC
ON CENTER
BFC
BELOW FINISHED CEILING
PB
PULL BOX
BPS
BOLTED PRESSURE SWITCH
PB
PUSHBUTTON
C
CONDUIT OR CONTROLLED RECEPT
PE
PNEUMATIC ELECTRIC
CAB
CABINET
PF
POWER FACTOR
CB
CIRCUIT BREAKER
PH
PHASE
CCTV
CLOSED CIRCUIT TV
PNL
PANEL
CKT
CIRCUIT
PRI
PRIMARY
CU
COPPER
RECEPT
RECEPTACLE
DN
DOWN
REFG
REFRIGERATOR
EC
ELECTRICAL CONTRACTOR
RTU
ROOF TOP UNIT
ELEC
ELECTRIC OR ELECTRICAL
SEC
SECONDARY
EM
EMERGENCY
SPKR
SPEAKER
EMT
ELECTRICAL METALLIC TUBING
SW
SWITCH
ENCL
ENCLOSURE
SWBD
SWITCHBOARD
EP
ELECTRIC PNEUMATIC
TEL
TELEPHONE
EPO
EMERGENCY POWER OFF
TR
TAMPER RESISTANT
EWC
ELECTRIC WATER COOLER
TSTAT
THERMOSTAT
F
FUSE OR FUSED
TYP
TYPICAL
FA
FIRE ALARM
UC
UNDER COUNTER
FACP
FIRE ALARM CONTROL PANEL
UG
UNDERGROUND
FSD
FIRE-SMOKE DAMPER
UH
UNIT HEATER
FV
FILM VIEWER
UNO
UNLESS NOTED OTHERWISE
G, GND
GROUND
USB
UNIVERSAL SERIAL BUS
GFI
GROUND FAULT INTERRUPTER
V
VOLT
IG
ISOLATED GROUND
VA
VOLT-AMP
JBOX
JUNCTION BOX
VAC
VOLTS ALTERNATING CURRENT
KV
KILOVOLT
VDC
VOLTS DIRECT CURRENT
REV
KVA
KILOVOLT-AMP
W
WATT OR WIRE
B4
KW
KILOWATT
WP
WEATHERPROOF
KWH
KILOWATT-HOUR
XFMR
TRANSFORMER
DUNHAM PROJECT NUMBER: 0417177-000
FIRM LICENSE NUMBER: F-1115
PROJECT INFORMATION
DRAWING LOG
DATE
COMMENT
9/15/17 BULLETIN #4
CONFIDENTIALITY NOTICE
BY ACCEPTING THIS MATERIAL, THE
RECIPIENT ACKNOWLEDGES AND
AGREES THAT THE INFORMATION
CONTAINED HEREIN IS OF A
CONFIDENTIAL NATURE AND THAT
THE RECIPIENT WILL NOT COPY,
DISCLOSE, DISTRIBUTE OR
OTHERWISE TRANSMIT IN ANY WAY
ANYTHING HEREIN, EITHER IN
WHOLE OR IN PART, WITHOUT THE
PRIOR WRITTEN PERMISSION OF
LIFE TIME FITNESS, INC. OR ITS
SUBSIDIARIES (THE "COMPANY"),
COMPLETING THE POTENTIAL
TRANSACTION CONTEMPLATED BY
EXCEPT FOR THE SPECIFIC
PURPOSE OF ANALYZING AND THIS
MATERIAL.THIS MATERIAL REMAINS
THE SOLE PROPERTY OF THE
COMPANY AND THE COMPANY
RESERVES THE RIGHT TO REQUIRE
ITS RETURN AT ANY TIME.
TECHNOLOGY TITLE SHEET
##
DESCRIPTION
19250 GULFBROOK DRIVE
FRIENDSWOOD, TX 77546
SYMBOL
Sheet
Number
Sheet Name
T0.1
TECHNOLOGY TITLE SHEET
T1.1
DATA/ PHONE PLAN - FIRST FLOOR
T1.2
DATA/ PHONE PLAN - SECOND FLOOR
T2.1
CCTV PLAN - FIRST FLOOR
T2.2
CCTV PLAN - SECOND FLOOR
T3.1
A/V PLAN - FIRST FLOOR
T3.2
A/V PLAN - SECOND FLOOR
T3.3
WORKOUT FLOOR SPEAKER PLAN - SECOND FLOOR
T3.4
TECHNOLOGY PLAN - FITNESS EQUIPMENT
T3.5
TECHNOLOGY PLAN - EXTERIOR POOL AREA
T3.6
TECHNOLOGY PLAN - EXTERIOR TENNIS AREA
T5.1
DATA/PHONE RISER DIAGRAM
T5.2
VIDEO DISTRIBUTION DIAGRAM
T6.1
TECHNOLOGY SCHEDULES AND DETAILS
T6.2
TECHNOLOGY SCHEDULES AND DETAILS
Grand total: 15
BAYBROOK
TECHNOLOGY SYMBOL SCHEDULE
ISSUE DATE
04/06/2017
SHEET NO.
T0.1
PUBLICATIONS
Issued For Permit and Bid
APP. NUMBER:
Download PDF