IPR7722ESX / LR7722EX
D/N 1080P HD Vari-Focal Infrared IP Camera
Quick Installation Guide
66-IPR7722CSM
CAUTION
Do not drop or strike this equipment
Do not install the equipment near any naked flames or heat
sources
Do not expose this unit to rain, moisture, smoke or dust
environment
Do not cover the opening of the cabinet with cloth and plastic or
to install this unit in poor ventilated places. Allow 10cm between
this unit and its surroundings
Do not continue to operate the unit under abnormal conditions
such as detection of smoke, strange smell or no display on
screen while power is turned on
Do not touch the power connection with wet hands
Do not damage the power cord or leave it under pressure
Do not operate this unit near magnet, speaker system, etc., to
avoid unnecessary magnetic interference
Connection cables should be grounded properly
English
Product Overview
Unit: mm
Sun Shield
Top Cover
Bottom Chassis
Bracket
Pan Adjustment Screw
Tilt Adjustment Screw
Lens
1. Take out the bracket from the box. Put the DC12V power cable
and network cable through the bracket and then fix it to the wall
(FIG.1 & FIG.2).
2. Take out the camera body and open the top cover with screw
driver (FIG.3).
3. Put the DC12V power cable and network cable through the
bracket rubber and then pull the cables through the bottom of
camera body (FIG.4). Connect the DC12V power cable to the
terminal and connect the network cable to RJ-45 slot of the
camera (FIG.5).
English
Installation
5. Loose the pan and tilt adjustment screws on the bracket to turn
the camera body to the desired angle and then tighten the
screws (FIG.7).
6. Adjust the lens on focus and zoom for recording clear video
image. After that, tighten the screws (FIG.8).
7. Replace the top cover and tighten the screws (FIG.9 & FIG.10).
English
4. Use the provided M5.0x10 screws (2 silver ones) to fix the
camera body on the bracket with screw driver (FIG.6).
English
System Overview
Top View
Input/Output Device Component Description
Alarm In/Out & Audio In/Out Connector
SD Card Connector
RJ-45 Jack
Video Out Jack
Load Default Button
DC12V Power Input Connector
(1). Use DC12V power adapter and a network switch to connect to
the network.
HD IP CAMERA
(2). Use a PoE network switch to connect to the network.
HD IP CAMERA
(3). Use a PoE power injector and a network switch to connect to
the network.
HD IP CAMERA
English
System Architectures
For connecting HD IP cameras to the network, please follow one of
the system architectures:
NOTE: For user convenience, restoring the factory default settings
will revert to the default IP address 192.168.0.200.
Before Accessing IP Cameras
Before accessing the IP camera, make sure that the camera’s RJ-45
network, audio, and power cables are properly connected. To set the
IP address, consult your network administrator for an available IP
address. The default IP address for each IP camera is 192.168.0.200.
Users can use the default IP address for verifying the camera’s
network connection.
Software Requirements
Merit LILIN Universal ActiveX software components are required for
web interface display of JPEG or H.264 Full HD video. When you login
to the IP camera by Internet Explorer, the security warning dialog box
will prompt the installation of the LILIN Universal ActiveX. Click Install
to download it.
English
Emergency Factory Default
To restore factory default settings by hardware, please follow these
steps:
1. Hold “RESET Key” for 10 seconds, then release.
2. After about 40 seconds, the network LED light should turn off,
and the back on again.
3. This camera has completed the factory default settings, and can
then reboot.
4. Search for the IP device using the IPScan software.
5. Start the IP device via Internet browser.
6. Enter the default username “admin” and password “pass” to
operate.
English
Configuring IP Addresses by IPScan Software
To configure an IP address using the IP scan tool, you can copy the
IPScan software from the installation CD, and paste to your computer.
Alternatively, you can execute the IPScan software from the
installation CD, or download the software from the Merit LILIN
website (www.meritlilin.com). To change the settings of the IP
address, subnet mask, gateway, or HTTP port, you can follow the
steps below:
1. Run the IPScan software.
2. Click Refresh. All available devices should be listed in the device
list.
3. Select your device from the list provided.
4. Change the IP address, subnet mask, gateway, or HTTP port for
the IP camera.
5. Click Apply to submit the settings.
6. Click Refresh to verify the settings.
English
Configuring IP Addresses via Web Interface
To change an IP address via web interface, type the default IP address
(192.168.0.200) in the Internet browser and follow the steps below:
1. Login to the H.264 Full HD IP camera by the default username
“admin” and default password “pass”
2. Click Basic Mode configuration hyperlink.
3. Click Network->General hyperlink.
4. Change the IP address, subnet mask, gateway, or HTTP port for
the IP camera.
5. Click Submit to verify the settings.
Internet Browser Settings & Application Required
Make sure your Internet browser allows the signed ActiveX plug-in to
work on your computer. Set “Download Signed ActiveX plug-in
controls” to “Prompt” and “Run ActiveX control and plug-in” to
“Enable”. You can set this option via Internet Explorer-> Tools->
Options-> Security Settings.
English
Once complete, you can access the IP camera’s live video by entering
the default IP address via your Internet browser. As the security
warning dialog box appears, click OK to download the ActiveX
directly from the IP camera.
Login
There are two levels of user authentication, including admin and
guest, that can access the IP camera. Administrator is authorized to
reset basic mode settings and see live video, while the guest is
allowed to see only live video.
English
The default usernames and passwords are as follows:
Username
Administrator
admin
Viewer
guest
Password
pass
guest
To logon the H.264 FULL HD IP camera, please type username and
password in logon HTML page and click on Submit button to enter
the system.
IPR7722ESX / LR7722EX
D/N 1080P HD Vari-Focal Infrared IP Camera
Quick Installation Guide
66-IPR7722CSM-2