Cube Air System Reciprocating Compressor

Cube Air System Reciprocating Compressor
Installation
Guide
Notice: Air compressors should only be installed trained installation personnel
call 800-531-9656 to find a local trained air compressor service technician.
Warning: Read all installation steps, compressor package operation manual,
notices and warnings prior to beginning compressor package installation.
Failure to do so can result in personal injury or damage to compressor package.
Warning: Always wear proper protective eye wear, hearing
protection, and other mandated safety clothing and devices
when installing compressor packages
Notice: Compressor package should not be mounted to
a moving piece of equipment that will be moving while
the compressor package is in operation. The compressor
package should not be mounted to a piece of equipment
that adds additional vibration to the compressor package.
The compressor package is only designed to handle its own
organic vibration during operation. Failure to follow either
one of these guidelines may result in pre-mature failure of
compressor package, components and/or personal injury.
ATTENTION: All incoming electrical power connections are
to be made on the main motor contactor(s) DO NOT attach
incoming power wires to package pressure switch. This will
result in electrical component damage not covered under
warranty.
NOTICE: To ensure full compressor tank warranty all tank
mounted compressor packages must be mounted on
factory supplied vibration isolation pads.
Warning: Before beginning steps 6-17 verify power supply is
off to compressor disconnect, and compressor package
Notice: All compressor air receivers should be inspected by a certified pressure vessel technician at least once per year, to check
for leaks, weak points in the metal or any other deformity of the air receiver. If at any time a receiver appears out of conformance
with ASME/CRN certification or a deformity is believed to have developed no matter how minor it may appear the tank should
be locked out of service immediately
Quality Air Compressor at a Great Price.
2626 Skyway Drive
Grand Prairie, TX, 75052
417-206-6353
800-531-9656
NEC (National Electric Code) Guide Lines
1 Phase Motor Requirments (Copper wire must be THW, THHN-THWN, XHHW) No solid core wire
NOTE: Wire size is based on being within 30ft of main electrical panel installation further would need a qualified electrian to properly
size the wire to account for voltage drop
Horse Power
Voltage
Instantaneous Trip Circuit Breaker Rating
Circuit Breaker Trip Rating
Minimum Wire Size
1.5
115
30
40
12
1.5
230
15
20
14
2
115
50
50
10
2
230
30
30
14
3
115
50
70
8
3
230
30
40
12
5
230
50
60
10
7.5
230
70
80
8
10
230
90
100
4
NOTE: Some rotary screw compressors have additional drive motors for the coolings fans these need to be taken into account when sizing the electrical system
3 Phase Motor Requirments (Copper wire must be THW, THHN-THWN, XHHW) No solid core wire
NOTE: Wire size is based on being within 30ft of main electrical panel installation further would need a qualified electrian to properly
size the wire to account for voltage drop
Horse Power
Voltage
Circuit Breaker
Trip Rating
Minimum Wire
Size
Horse Power
Voltage
Circuit Breaker
Trip Rating
Minimum Wire
Size
3
200
20
14
30
200
150
2
3
230
20
14
30
230
125
3
3
460
15
14
30
460
80
8
3
575
15
14
30
575
60
8
5
200
35
12
40
200
200
1/O
5
230
30
14
40
230
175
1
5
460
15
14
40
460
100
6
5
575
15
14
40
575
80
6
7.5
200
50
10
50
200
200
3/O
7.5
230
45
10
50
230
200
2/O
7.5
460
20
14
50
460
125
4
7.5
575
20
14
50
575
100
6
10
200
60
8
60
200
250
4/O
10
230
60
10
60
230
225
3/O
10
460
35
14
60
460
125
3
10
575
25
14
60
575
125
4
15
200
90
6
75
200
300
300
15
230
80
6
75
230
300
250
15
460
45
10
75
460
150
1
15
575
40
12
75
575
125
3
20
200
100
4
100
200
400
500
20
230
90
4
100
230
400
350
20
460
60
10
100
460
200
2/O
20
575
50
10
100
575
175
1
25
200
125
3
25
230
125
4
25
460
70
8
25
575
60
10
NOTE: Some rotary screw compressors have additional drive motors for the coolings fans these need to be taken into account when sizing the electrical system
Proper Installation Electric Reciprocating Compressor
Warning: Always wear proper protective eye ware, hearing protection and safety clothing when working around the
compressor package. No loose or baggy clothing should be worn around compressor package at any time.
Warning: On Electric motor powered air compressors make sure electrical system is up to National Electric Code (NEC) prior
to installing compressor system. Failure to install a compressor with a proper NEC electrical system can cause personal injury,
compressor package damage and void compressor package warranty.
Notice: To ensure full compressor tank warranty all tank mounted compressor packages must be mounted on factory approved
vibration isolation pads. A compressor should NEVER be installed while still on or in its original packaging. Failure to properly
install the compressor system with approved vibration isolation pads will result in the compressor tank warranty being void.
Notice: Compressed Air Systems compressors can operate at pressures from 0-250psi depending on the compressor package
design and build specifications. Always verify that the system the compressor is installed into can handle the maximum
operational pressure the compressor. NEVER install a compressor in a system that can not handle the compressors maximum
operating pressure.
Notice: Compressed air is extremely dangerous when not properly used or installed. Always make sure a trained compressed air
professional has looked over the air system prior to use. Improper installation or use of compressed air can cause bodily injury or
death. NEVER pressurize an object that was not designed to be pressurized. Pressurizing objects not properly engineered for the
Step
maximum operating pressure of the compressor system can cause bodily injury or death.
1
Verify compressor package install site can handle weight load of compressor package.
(Note: this should have been done prior to the sale of the compressor package)
Notice: Installing compressors on the roof, mezzanine, 2nd story or higher of a building can result in higher DBA readings
for the compressor package as well as additional vibration
Step
2
Make sure compressor installation site is clear of debris and has adequate space around were the compressor will sit for
service (minimum of 24in.) and ventilation (must be able to get clean fresh air through oil/air cooler during operation,
without recirculating cooler hot air discharge) If site is excessively dusty or dirty due to grinding, sanding, or due to the
nature of the selected application site a new site should be sought out.
Step
3
Make sure site voltage for compressor installation is correct
(When reading voltage read across the lines to get and exact voltage. On single phase units read across L1 (Line 1) and
L2 (Line 2) to get the operational voltage. On 3 phase units read across L1 to L2, then L2 to L3 (Line 3), then from L1 to L3
this gives the most accurate reading of the voltage. It is also recommended to read the voltage at both the main electrical
panel and at the compressor disconnect to check for voltage drops prior to installation)
A. 208-230 volt compressors can operate on voltages from 207-253 volts
B. 460-480 volt compressor can operate on voltage from 420-505 volts
C. On either 208-230 or 460-480 volt compressor packages; the lower the site voltage, the more amps the compressor
motor will draw. (See electric motor MFG. website for amp draw at 208 volt if applicable)
D. If voltage is lower than 207 on 208-230 or higher than 505 on 460-480 volt package then, a special low or high voltage motor is required as well as a different motor contactor and controls (this should be confirmed prior to compressor sale)
E. If compressor package is being powered by a generator verify generator has enough power to start the compressor
package. An easy calculation for the amount of power require to start a compressor is below.
Max running amps X operating voltage = running kilowatts (then) Running Kilowatts x 4= Starting Kilowatts required to
start the compressors drive motor.
Notice:
Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained
air compressor service technician
Proper Installation Electric Reciprocating Compressor
Warning: Always wear proper protective eye ware, hearing protection and safety clothing when working around the
compressor package. No loose or baggy clothing should be worn around compressor package at any time.
Warning: On Electric motor powered air compressors make sure electrical system is up to National Electric Code (NEC) prior
to installing compressor system. Failure to install a compressor with a proper NEC electrical system can cause personal injury,
compressor package damage and void compressor package warranty.
Notice: To ensure full compressor tank warranty all tank mounted compressor packages must be mounted on factory approved
vibration isolation pads. A compressor should NEVER be installed while still on or in its original packaging. Failure to properly
install the compressor system with approved vibration isolation pads will result in the compressor tank warranty being void.
Notice: Compressed Air Systems compressors can operate at pressures from 0-250psi depending on the compressor package
design and build specifications. Always verify that the system the compressor is installed into can handle the maximum
operational pressure the compressor. NEVER install a compressor in a system that can not handle the compressors maximum
operating pressure.
Notice: Compressed air is extremely dangerous when not properly used or installed. Always make sure a trained compressed air
professional has looked over the air system prior to use. Improper installation or use of compressed air can cause bodily injury or
death. NEVER pressurize an object that was not designed to be pressurized. Pressurizing objects not properly engineered for the
maximum operating pressure of the compressor system can cause bodily injury or death.
Step
4
Verify that main power wires leading to compressor disconnect are proper size per National Electric Code (NEC) and local
applicable standards. Failure to have properly sized wire can cause damage to the electrical components of the compressor
package. Incorrect wire size for the compressor package may also result in the loss of electric component warranty.
Step
5
Verify that the breaker for the compressor is properly sized for the compressor total full load amps. NEC and local applicable standards should be followed. Failure to do so will result in damage to electrical components. Incorrect breaker size
STOP
Warning: Before beginning steps 6-17 verify power supply is off to compressor disconnect, and
compressor package
6
for the compressor package may also result in the loss of electric component warranty.
Step
Uncrate compressor package (verify package is intact and not missing parts).
Step
7
Remove compressor shipping pallet.
(Warning: Only use forklift or approved lifting device to remove compressor from shipping pallet)
Step
8
Set compressor into place on vibration isolation pads.
Step
9
Drill holes in floor through vibration pads and mounting location on compressor package to set compressor package
anchors in place.
Notice:
Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained
air compressor service technician
Proper Installation Electric Reciprocating Compressor
Warning: Always wear proper protective eye ware, hearing protection and safety clothing when working around the
compressor package. No loose or baggy clothing should be worn around compressor package at any time.
Warning: On Electric motor powered air compressors make sure electrical system is up to National Electric Code (NEC) prior
to installing compressor system. Failure to install a compressor with a proper NEC electrical system can cause personal injury,
compressor package damage and void compressor package warranty.
Notice: To ensure full compressor tank warranty all tank mounted compressor packages must be mounted on factory approved
vibration isolation pads. A compressor should NEVER be installed while still on or in its original packaging. Failure to properly
install the compressor system with approved vibration isolation pads will result in the compressor tank warranty being void.
Notice: Compressed Air Systems compressors can operate at pressures from 0-250psi depending on the compressor package
design and build specifications. Always verify that the system the compressor is installed into can handle the maximum
operational pressure the compressor. NEVER install a compressor in a system that can not handle the compressors maximum
operating pressure.
Notice: Compressed air is extremely dangerous when not properly used or installed. Always make sure a trained compressed air
professional has looked over the air system prior to use. Improper installation or use of compressed air can cause bodily injury or
death. NEVER pressurize an object that was not designed to be pressurized. Pressurizing objects not properly engineered for the
maximum operating pressure of the compressor system can cause bodily injury or death.
Warning: Before beginning steps 6-17 verify power supply is off to compressor disconnect, and compressor package
Step
10
Tighten compressor package anchor nuts to set anchors in floor.
Step
11
Back anchor nuts off to ½ to ¾ turn past hand tight.
Step
12
Set compressor tank into install position (if compressor tank is already installed skip steps 12-14)
Step
13
Drill mounting holes for compressor tank feet
Step
14
Set anchors for compressor tank mounting feet
Step
15
Install new compressor air reciever pressure gauge, make sure it is clearly visable to operator of compressor package.
Step
16
Install new air reciever safety valve (Ensure tank safety valve pressure is correct for the conpressor tank pressure rating and
flow of safety valve exceeds flow of compressor package)
Step
17
Install air lines connection fitting to compressor air reciever
Notice:
Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained
air compressor service technician
Proper Installation Electric Reciprocating Compressor
Warning: Always wear proper protective eye ware, hearing protection and safety clothing when working around the
compressor package. No loose or baggy clothing should be worn around compressor package at any time.
Warning: On Electric motor powered air compressors make sure electrical system is up to National Electric Code (NEC) prior
to installing compressor system. Failure to install a compressor with a proper NEC electrical system can cause personal injury,
compressor package damage and void compressor package warranty.
Notice: To ensure full compressor tank warranty all tank mounted compressor packages must be mounted on factory approved
vibration isolation pads. A compressor should NEVER be installed while still on or in its original packaging. Failure to properly
install the compressor system with approved vibration isolation pads will result in the compressor tank warranty being void.
Notice: Compressed Air Systems compressors can operate at pressures from 0-250psi depending on the compressor package
design and build specifications. Always verify that the system the compressor is installed into can handle the maximum
operational pressure the compressor. NEVER install a compressor in a system that can not handle the compressors maximum
operating pressure.
Notice: Compressed air is extremely dangerous when not properly used or installed. Always make sure a trained compressed air
professional has looked over the air system prior to use. Improper installation or use of compressed air can cause bodily injury or
death. NEVER pressurize an object that was not designed to be pressurized. Pressurizing objects not properly engineered for the
maximum operating pressure of the compressor system can cause bodily injury or death.
Step
18
Install discharge air line from cube air system compressor package to reciever
Step
19
Verify all airline fittings are tightened properly and all gauges and safety valves are sized properly
for the compressor package
Step
20
Connect airline to compressor package air discharge. (Note: It is recommended to use a flexible line between the compressor package and the system piping to avoid damage due to compressor vibration)
Step
21
Remove knock out on compressor operation panel or drill/cut hole for main electrical power wires for compressor. (No connections are to be made on the pressure switch during standard installation. Pressure switch's are pre-set from the factory)
Step
22
Attach incoming compressor package wire conduit to compressor operation panel.
Step
23
Install compressor package incoming power wires to proper terminal on main motor contactor.
A. On single phase compressor packages ports L1(line 1) and L2 (line 2)
B. On 3 phase compressor packages ports L1 L2 L3 (line 3)
Note: Make sure incoming power wires are properly torqued into place. This is also a good time to verify all electrical
power wires are torqued properly.
Step
24
Install ground wire in compressor panel.
Notice:
Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained
air compressor service technician
Proper Installation Electric Reciprocating Compressor
Warning: Always wear proper protective eye ware, hearing protection and safety clothing when working around the
compressor package. No loose or baggy clothing should be worn around compressor package at any time.
Warning: On Electric motor powered air compressors make sure electrical system is up to National Electric Code (NEC) prior
to installing compressor system. Failure to install a compressor with a proper NEC electrical system can cause personal injury,
compressor package damage and void compressor package warranty.
Notice: To ensure full compressor tank warranty all tank mounted compressor packages must be mounted on factory approved
vibration isolation pads. A compressor should NEVER be installed while still on or in its original packaging. Failure to properly
install the compressor system with approved vibration isolation pads will result in the compressor tank warranty being void.
Notice: Compressed Air Systems compressors can operate at pressures from 0-250psi depending on the compressor package
design and build specifications. Always verify that the system the compressor is installed into can handle the maximum
operational pressure the compressor. NEVER install a compressor in a system that can not handle the compressors maximum
operating pressure.
Notice: Compressed air is extremely dangerous when not properly used or installed. Always make sure a trained compressed air
professional has looked over the air system prior to use. Improper installation or use of compressed air can cause bodily injury or
death. NEVER pressurize an object that was not designed to be pressurized. Pressurizing objects not properly engineered for the
maximum operating pressure of the compressor system can cause bodily injury or death.
Step
25
Verify all wire terminal connections in compressor package are torqued to proper specs,
Step
26
Turn power on to the compressor package
Step
27
Verify voltage of incoming power on the main drive motor starter
Step
28
Turn compressor package on for 1-3 seconds to verify for proper compressor rotation (When facing the front of the compressor pump opposite the motor shaft, the compressor should turn clockwise) (Notice: Do not allow compressor to run for
more than 3 seconds on this step doing so may cause damage to compressor)
Step
29
If rotation is incorrect, turn power off to compressor package.
A. O
n 3 phase compressors; once power is confirmed to be off, switch incoming power wire from L1 to L3 position and
place L3 incoming power wire in L1 position.
B. On single phase compressor packages; if rotation is incorrect, check motor wiring diagram for proper rotation wiring
diagram.
Step
30
Close ball valve on compressor storage tank discharge.
Step
31
Turn power back on to compressor package.
Notice:
Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained
air compressor service technician
Proper Installation Electric Reciprocating Compressor
Warning: Always wear proper protective eye ware, hearing protection and safety clothing when working around the
compressor package. No loose or baggy clothing should be worn around compressor package at any time.
Warning: On Electric motor powered air compressors make sure electrical system is up to National Electric Code (NEC) prior
to installing compressor system. Failure to install a compressor with a proper NEC electrical system can cause personal injury,
compressor package damage and void compressor package warranty.
Notice: To ensure full compressor tank warranty all tank mounted compressor packages must be mounted on factory approved
vibration isolation pads. A compressor should NEVER be installed while still on or in its original packaging. Failure to properly
install the compressor system with approved vibration isolation pads will result in the compressor tank warranty being void.
Notice: Compressed Air Systems compressors can operate at pressures from 0-250psi depending on the compressor package
design and build specifications. Always verify that the system the compressor is installed into can handle the maximum
operational pressure the compressor. NEVER install a compressor in a system that can not handle the compressors maximum
operating pressure.
Notice: Compressed air is extremely dangerous when not properly used or installed. Always make sure a trained compressed air
professional has looked over the air system prior to use. Improper installation or use of compressed air can cause bodily injury or
death. NEVER pressurize an object that was not designed to be pressurized. Pressurizing objects not properly engineered for the
maximum operating pressure of the compressor system can cause bodily injury or death.
Step
32
(If rotation was incorrect) Turn compressor back on for 1-3 seconds to verify that rotation is now correct if needed.
Step
33
(Read 25A, 25B, 25C prior to starting Step 25)
Turn compressor package on with correct rotation and allow package to build to maximum operating pressure, and unload.
A. Check voltage on main motor contactor prior to starting.
B. Continue to check voltage on motor contactor as compressor package starts.
C. If voltage drops more than 5% or below 207 on 208-230 volt packages or below 420 on 460-480 volt packages; and
does not immediately return to original voltage, then check power supply.
(A drop of 5% or more; or below the minimum operating voltage of the electric motor can cause damage to the electrical
components of the compressor package resulting in loss of electrical component warranty. If drop occurs, contact electrician and compressor package owner to notify them of power issues that need to be corrected for proper operation.)
Step
34
Allow compressor package to run and reach maximum operating pressure then shut down (Compressor package will shut
down automatically at maximum operating pressure. Compressor package pressure switch has been pre-set at factory during testing. Do not adjust compressor package pressure switch without consulting the factory.)
Step
35
Open tank ball valve to pressurize air piping system (Note: This is a good time to listen and check for
leaks in the piping system)
Step
36
Using either compressor tank safety relief valve or tank discharge drain, release air pressure until compressor package re-
Notice:
Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained
air compressor service technician
Proper Installation Electric Reciprocating Compressor
Warning: Always wear proper protective eye ware, hearing protection and safety clothing when working around the
compressor package. No loose or baggy clothing should be worn around compressor package at any time.
Warning: On Electric motor powered air compressors make sure electrical system is up to National Electric Code (NEC) prior
to installing compressor system. Failure to install a compressor with a proper NEC electrical system can cause personal injury,
compressor package damage and void compressor package warranty.
Notice: To ensure full compressor tank warranty all tank mounted compressor packages must be mounted on factory approved
vibration isolation pads. A compressor should NEVER be installed while still on or in its original packaging. Failure to properly
install the compressor system with approved vibration isolation pads will result in the compressor tank warranty being void.
Notice: Compressed Air Systems compressors can operate at pressures from 0-250psi depending on the compressor package
design and build specifications. Always verify that the system the compressor is installed into can handle the maximum
operational pressure the compressor. NEVER install a compressor in a system that can not handle the compressors maximum
operating pressure.
Notice: Compressed air is extremely dangerous when not properly used or installed. Always make sure a trained compressed air
professional has looked over the air system prior to use. Improper installation or use of compressed air can cause bodily injury or
death. NEVER pressurize an object that was not designed to be pressurized. Pressurizing objects not properly engineered for the
maximum operating pressure of the compressor system can cause bodily injury or death.
starts. (Note: In most cases pressurizing the air piping system releases enough air from the system to re-start the compressor) (Warning: When releasing air from compressor safety relief valve or tank drain DO NOT look at valve or drain)
Step
37
Perform function test on compressor package operating system. Using STEP 28 allow the compressor package to build up
to maximum operating pressure and shut down or unload (dual control units only). Once shut down or unloaded (dual
control units only), release air from the system to cause the compressor package to restart or re-load (dual control units
only) and compress air. Repeat this process a minimum of 6 times.
Step
38
Check all compressor air lines for leaks, tighten fittings as needed.
Step
39
Check compressor tank drain for proper function. If drain has a timer feature, set timer to appropriate setting. Timer operated drains have a test button, use this to check for proper function. (Warning: Never look directly at compressor drain
when testing or during drain operation)
Step
40
Make sure compressor installation sheet is properly filled back out to be sent in for warranty registration
Step
41
Go over general operation and maintenance instructions of compressor package with owner and other personal that work
around the compressor package. Verify if a maintenance agreement has already been set up or if one needs to be established.
Step
42
Turn compressor back on wipe down surfaces and make sure installation sheet is complete. Compressor is now ready for
full operation.
Notice:
Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained
air compressor service technician
INDUS
C
E R T I F I C A T E
TRIAL GOLD
O F
Reciprocating Compressors
All component parts on this compressor installed by the
manufacturer are warranted to be free of defects, workmanship and material for a period of one year. Transportation charges are the responsibility of the purchaser.
This warranty extends to the original purchaser of the
compressor only. The purchaser must use Compressed
Air Systems synthetic reciprocating compressor oil in
the compressor for the duration of the compressor warranty.
L
I M I T E D
W
A R R A N T Y
Specialty compressor-any compressor package with options other than those that apply to the standard model
number in the catalog
BEFORE WARRANTY SERVICE IS PERFORMED
CONTACT MANUFACTURER TECH SUPPORT
FOR FASTEST SOLUTION
Warranty labor for the first year is only covered for
work performed Monday-Friday 8am-5pm excluding
all major US holidays
There are NO express warranties except other than
those contained in this limited warranty statement
Optional 6 year Industrial reciprocating pump
only warranty
Covered in the one year period of the warranty are defective parts due to defects in the original part only.
To be applicable for this option purchaser must purchase the Full Year reciprocating compressor maintenance kit at the same time as the compressor. A subsequent kit must be purchased every 12 months from the
date of the original purchase for a total of 6 kits during
the warranty of the period of the pump. The purchaser
must use only Compressed Air Systems synthetic
reciprocating compressor oil in the compressor for the
duration of the compressor warranty.
The compressor warranty is void in the case of abuse,
lack of proper service, in correct application, in correct
installation, and neglect
Standard compressor warranty covers defective parts
and labor for the one year period.
Industrial Electric stationary compressors may be
repaired on site as long as the compressor is not located
further than 50 miles from the service center. The purchaser is responsible for any additional travel expense
past 50 miles from the service center.
Gas/Diesel engine driven, Single stage stationary, and
Contractor series compressors must be repaired at the
closest service center to the compressor. The purchaser
is responsible for any travel expense if they do not wish
to bring the compressor to the service center.
ALL “SPECIALTY COMPRESSOR” WARRANTY
SERVICE MUST BE PERFORMED AT THE CLOSEST SERVICE CENTER TO THE COMPRESSOR
The warranty covers the Industrial reciprocating pump
for a period of 6 years parts replacement only for any
part with a defect from the manufacturer, excluding the
compressor valves which carry the same 1 year standard warranty. The warranty does not cover standard
wear and tear on parts, abuse, neglect, improper service,
misapplication, and improper installation. The purchaser is responsible for any freight/shipping expense
incurred.
BEFORE WARRANTY SERVICE IS PERFORMED
CONTACT MANUFACTURER TECH SUPPORT
FOR FASTEST SOLUTION
Proper Installation Electric Reciprocating Compressor
Reciprocating Compressor Installation Sheet
Date of Installation ________________________________ Compressor Model# ____________________________________
Installation Company ______________________________
Compressor Serial # __________________________ __________
Installation Technician _____________________________
Compressor Voltage __________________________ __________
Site Electrical Phase _______________________________
Site Voltage L1 _______ L2 _______ L3 _______
Compressor Electrical breaker size____________________
Incoming Voltage at motor start up L1 _______ L2 _______ L3 _______
Incoming Voltage at max operating pressure L1 _______ L2 _______ L3 _______
Incoming power connected to Magnetic Starter ________
Breaker size for the compressor _________________AMPS
Wire size for the compressor ______________________ _______
Distance from main electric panel ____________________
Disconnect installed at the compressors site _________ _______
If Duplex compressor separate disconnects for each drive motor:
Compressor Rotation Correct
N Yes N No
N Yes N No
Motor amps at max operating Pressure L1 _______ L2 _______ L3 _______
Compressor Max Operating Pressure _________________
Compressor tank drain functional _________________________
Unit inspected for Air leaks _________________________
Unit inspected for Oil leaks ______________________________
Unit location:
N Indoors N Outdoors
Unit tank fill time 0-125psi _________________________ (Put N/A if pressure not applicable to installed unit)
Unit tank fill time 0-150psi _________________________ (Put N/A if pressure not applicable to installed unit)
Unit tank fill time 0-175psi _________________________ (Put N/A if pressure not applicable to installed unit)
_
Vibration Pads properly installed: N Yes N No
N Yes N No
All installation steps completed: N Yes N No If no, reason: ____________________________________________________
Belt tension checked:
_________________________________________________________________________________________________________
_________________________________________________________________________________________________________