DA - 11359 - Worldwide

QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Overview
1. 1.44MB Floppy Drive
5. Front Bezel
2. High Speed IDE CD-ROM
6. 5.25-inch Removable Media Bays
3. Diagnostic Lighting
7. Seven PCI-X slots
4. Wide Ultra3/Ultra4 Hot Plug Drive Bays (12 x 1" Standard)
8. Memory Board
1. Rack Handles
4. Diagnostic Lighting
2. 1.44MB Floppy Drive
5. Wide Ultra3/Ultra4 Hot Plug Drive Bays (12 x 1" Standard)
3. High Speed IDE CD-ROM
6. 5.25-inch Removable Media Bays
What's New
Intel® Xeon 3.0GHz Processors with 400MHz system bus
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 1
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Overview
At A Glance
Designed for maximum application performance and user workload, the ML530 Generation 2 (G2) offers customers the first 2P expansion server with
Mirrored Memory
Intel Xeon 3.0 GHz, 2.80GHz or 2.40GHz Processors with 400MHz system bus
512-KB level 2 cache per processor
Enterprise Class chipset: ServerWorks GC HE
PC 1600 ECC SDRAM memory expandable to 16 GB (Advanced ECC memory standard)
2:1 interleaved memory
Seven 64-Bit/100 MHz PCI-X slots; 4 Hot Plug Slots
Two Ultra3 SCSI Drive Cages standard support up to 12 1" hot plug hard drives
Internal mass storage capacity up to 2.055 TB (12 x 145.8 GB + 2 x 145.8 GB 1" hot plug drives) with optional ML5xx Internal Two Bay Hot Plug
SCSI Drive Cage (with fan)
Compaq Advanced Memory Protection including Mirrored Memory and Online Spare Memory
600-Watt Hot Plug Power Supply with optional 1+ 1 redundancy
Hot Plug System Fans with optional redundancy
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 WOL (Wake On LAN) and PXE support
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Protected by Compaq Services, including a three-year, Next Business Day on-site, limited, Global warranty and extended Pre-Failure Warranty that
covers processors, memory and disk drives — Certain restrictions and exclusions apply. Consult the Compaq Customer Support Center at 1-800-3451518 for details.
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 2
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Standard Features
Intel Xeon 3.0 GHz/512 KB Processor (with 400 MHz system bus)
NOTE: 1P Models ship with one processor standard. 2P Models ship with two processors standard.
Processor
Intel Xeon 2.80 GHz/512 KB Processor (with 400 MHz system bus)
NOTE: 1P Models ship with one processor standard. 2P Models ship with two processors standard.
Intel Xeon 2.40 GHz/512 KB Processor (with 400 MHz system bus)
NOTE: 1P Models ship with one processor standard. 2P Models ship with two processors standard.
Cache Memory
512-KB level 2 cache per processor
Upgradability
Upgradable to dual processing
NOTE: 1P Models only.
Enterprise Class chipset: ServerWorks GC HE
Chipset
NOTE: For more information regarding ServerWorks, please see the following URL:
http://www.serverworks.com/products/overview.html.
Memory
Network Controller
Expansion Slots
Standard
1024 MB (2 x 512 MB) PC1600-MHz Registered ECC SDRAM
Maximum
16,384 MB
Embedded NC3163 Fast Ethernet NIC PCI 10/100 with full WOL (Wake On LAN) and PXE support
Bus Number
Hot Plug
PCI Voltage
Notes
1
64-bit/100MHz PCI-X
Bus Speed
1
Yes
3.3V
-
2
64-bit/100MHz PCI-X
1
Yes
3.3V
-
3
64-bit/100MHz PCI-X
5
Yes
3.3V
-
4
64-bit/100MHz PCI-X
5
Yes
3.3V
-
5
64-bit/100MHz PCI-X
9
No
3.3V
-
6
64-bit/100MHz PCI-X
9
No
3.3V
-
7
64-bit/100MHz PCI-X
13
No
3.3V
Preferred RILOE slot
NOTE: For more information regarding PCI-X, please see the following URL: http://www.HP.com/pci-x.
NOTE: All slots can accept universal keyed PCI cards.
Storage Controllers
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Storage
Diskette Drives
1.44 MB
CD-ROM
40x IDE CD-ROM Drive
Hard Drives
None
Internal Storage
2.055 TB (with optional ML5xx Internal Two Bay Hot Plug Wide SCSI Drive Cage (with fan)
(12 x 146.8-GB 1" + 2 x 146.8-GB 1")
Half Height Bays
2 bays for optional tape backup, DVD, or SCSI devices
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 3
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Standard Features
Interfaces
Parallel
1
Serial
2
Pointing Device (Mouse)
1
Graphics
1
Keyboard
1
Network RJ-45
1
USB
2
NOTE: Please see the following URL for additional information regarding USB support:
http://h18004.www1.hp.com/products/servers/platforms/usb-support.html.
External SCSI
1
Graphics
Integrated Rage XL Video Controller with 8 MB SDRAM Video Memory
Form Factor
Tower or Rack (7U)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 4
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Standard Features
ProLiant Essentials
Foundation Pack
Software
Insight Manager 7 andf HP
Systems Insight Manager
Insight Manager 7 and HP's new HP Systems Insight Manager help maximize system
uptime and performance and reduce system maintenance costs by providing proactive
notification of problems before those problems result in unplanned downtime or reduced
productivity. Insight Manager 7 and HP Systems Insight Manager are both easy to set up
work with the Insight Management Agents, integrated Light-Out and Remote Insight LightOut Edition, and Version Control Agents to deliver robust fault, configuration, and asset
management as well as remote administration. With HP Systems Insight Manager
customers will also be able to take advantage of role-based security; the ability to manage
ProLiant, Integrity, and HP 9000 systems; and plug-ins for storage, client, printer, and
power management as well as server rapid deployment, performance management, and
workload management. For more details on HP Systems Insight Manager visit
http://www.hp.com/go/hpsim.
Management Agents
The Management Agents form the foundation for HP's Intelligent Manageability strategy.
They provide direct, browser-based access to in-depth instrumentation built into HP servers,
workstations, desktops, and portables, and send alerts to Insight Manager 7 and other
enterprise management applications in case of subsystem or environmental failures. For
additional information about the Management Agents and other management products
from HP, please visit the management Web site at http://www.hp.com/servers/manage.
SmartStart
SmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable
and consistent server configurations. For more information, please visit the SmartStart Web
site at http://www.hp.com/servers/smartstart.
SmartStart version supported (minimum): SmartStart 6.0
ActiveUpdate
ActiveUpdate is a web-based application that keeps IT managers directly connected to HP
for proactive notification and delivery of the latest software updates.
ROMPaq, support software,
and configuration utilities
The latest software, drivers, and firmware fully optimized and tested for your ProLiant server
and options.
Survey Utility and diagnostics
utilities
The most advanced configuration analysis, reporting and troubleshooting utilities used by
Compaq and at your fingertips.
Optional ProLiant Essentials
Value Packs
Optional software offerings that selectively extend the functionality of an Adaptive
Infrastructure to address specific business problems and needs:
Rapid Deployment Pack – an automated solution for multi-server deployment and
provisioning, enabling companies to quickly and easily adapt to changing
business demands.
Workload Management Pack – provides easier management of complex
environments, improving overall server utilization and enabling Windows 2000
customers for the first time to confidently deploy multiple applications on a single
multiprocessor ProLiant Server.
Performance Management Pack – a performance management solution that
identifies and explains hardware performance bottlenecks on ProLiant servers and
attached options enabling users to better utilize their valuable resources..
NOTE:
NOTE Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to
http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more
information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL:
http://www.hp.com/servers/proliantessentials.
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 5
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Standard Features
Industry Standard
Compliance
ACPI 1.0b Compliant
PCI 2. 2 Compliant
PCI-X 1.0 Compliant
WOL Support
Microsoft® Logo certifications
Novell certified
Availability
Compaq Advanced Memory Protection Technology – delivers unsurpassed memory protection and server availability:
Advanced ECC Memory
ECC protection provides the ability to detect and correct single bit memory errors while Advanced ECC extends this
coverage to include protection against multiple simultaneous errors on a DIMM. Advanced ECC detects and
corrects 4bit memory errors that occur within a single DRAM chip on a DIMM. Advanced ECC algorithms work in
combination with industry standard ECC DIMMS.
Advanced Memory Protection Configurations
Online Spare Memory
Offers a higher level of memory protection than Advanced ECC alone. The system is configured with a spare bank
of memory. If the number of single-bit correctable errors on a bank exceeds the pre-defined error threshold, the
failing bank will fail over to the Online Spare bank without intervention or server interruption. The failed memory
can then be replaced at the user's convenience during a scheduled maintenance window.
Single-Board Mirrored Memory
Single-board mirrored memory provides a higher level of availability than Advanced ECC and Online Spare
Memory because it protects against multi-bit errors. Single-board Mirrored Memory uses a single memory board that
is configured with a mirrored/redundant set of memory. The system writes to both sets of memory, but reads from
one. If a memory bank has a multi-bit error or full DIMM failure, the system simply reads from the mirrored bank
instead. This process occurs without intervention or server interruption, and the failed DIMM can be replaced during
a regularly scheduled shutdown.
NOTE: All Compaq Advanced Memory Protection modes are configured in the ROM-Based Setup Utility (RBSU) and
viewable through Insight Manager 7 (CIM 7) and the Integrated Management Log (IML).
PCI-X Hot Plug Technology (Four 64bit/100MHz PCI-X hot plug slots available)
One 600W Hot Plug Power Supply standard
Two Hot Plug System Fans standard
Intelligent Manageability Insight Manager 7
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM Utility
Remote Lights-Out Edition (optional)
Automatic Server Recovery-2 (ASR-2)
Integrated Management Log
Server Health Logging
Drive Parameter Tracking (with Smart Array Controller)
Dynamic Sector Repairing (with Smart Array Controller)
Pre-Failure Warranty (covers processors, hard drives and memory)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 6
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Standard Features
Security
Power-on password
Hot plug keyboard password
Diskette drive control
Diskette boot control
QuickLock, Network Server Mode
Parallel and serial interface control
Administrator's password
Disk configuration lock
Server Power Cords
One Lowline power cord ships standard
Power Supply
One 600W Hot Plug Power Supply standard
Optional 2nd Power Supply for 1+ 1 redundancy
NOTE: Redundant Hot Plug Power Supplies standard on 2P servers.
NOTE: North American variants ship with IEC320-C13 to Nema 5-15P detachable power cord. (Rack models only).
System Fans
Two Hot Plug System Fans standard
Optional Hot Plug Redundant Fan kit includes two more
NOTE: Hot Plug Redundant Fans standard on 2P servers.
Required Cabling
For required cabling information, refer to the HP Web site at
http://h18000.www1.hp.com/products/servers/proliantML530/.
OS Support
Microsoft Windows NT® Server
Microsoft Windows NT Enterprise Edition
Microsoft Windows 2000
Windows Server 2003
Novell NetWare
SCO UnixWare
LINUX (Red Hat, SuSE)
Sun Solaris Intel Platform Edition
Caldera OpenUnix
OS/2 e-Business
NOTE: For a more complete and up-to-date listing of supported OS's and versions, please visit our OS Support Matrix at:
ftp://ftp.compaq.com/pub/products/servers/os-support-matrix-310.pdf.
NOTE: For an up-to-date listing of the latest drivers available for the HP ProLiant ML530 G2, please see:
http://h18023.www1.hp.com/support/files/server/us/index.html.
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 7
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Standard Features
Rack Airflow Requirements
Rack 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rackmounted servers. The 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these racks to
be fully loaded with servers using the latest processors.
CAUTION:
CAUTION If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to
prevent damage to the equipment:
Front and rear doors: If your 42U server rack includes closing front and rear doors, you must allow 830 square
inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow (equivalent to the
required 64 percent open area for ventilation).
Side: The clearance between the installed rack component and the side panels of the rack must be a minimum of
2.75 inches (7 cm).
CAUTION: Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE: For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the
server, or to the server documentation located in the Support section at the following URL:
http://h18000.www1.hp.com/products/servers/ProLiantml530/index.html.
Installation of Compaq
servers into Third Party
Round Hole Racks
If a Third Party rack is used, an additional rack kit will need to be used with the rack kit that comes with the server. The
additional rack kit part number is Compaq part number 274739-B21. The rack kit comers with all necessary brackets,
hardware and installation instructions.
NOTE: Third party square-holed racks are supported using the standard rack rail kit that ships with the rack server models.
Installation of Compaq
servers into Telco Racks
If a Telco is used, an additional rack kit and brackets will need to be used with the rack kit that comes with the server
(optional Third Party Rack Kit (PN: 274739-B21)). Please see the following URL to purchase the brackets (rack kit and
brackets come with all necessary brackets, hardware, and installation instructions:
http://www.racksolutions.com/compaq/products.htm.
HP Factory Express
Capabilities
HP Factory Express gives you the flexibility to choose from a full menu of factory capabilities all in one manufacturing
facility, in one process, with one touch giving you full control and access to HP's World class manufacturing facility
anytime. This approach provides you the speed to deploy your IT needs, with total quality assurance, reliability, and
predictability to lower your total cost of ownership by letting HP install, rack, and customize your software and hardware
options for you.
Service and Support
HP Services provides a three-year, limited warranty, including Pre-Failure Warranty (coverage of hard drives, memory and
processors) fully supported by a worldwide network of resellers and service providers and lifetime toll-free 7 x 24 hardware
technical phone support. In addition, available service offerings include:
NOTE: Limited Warranty includes 3 year Parts, 3 year Labor, 3-year on-site support.
A full range of HP Care Pack packaged hardware and software services:
Installation and start up
Extended coverage hours and enhanced response times
System management and performance services
Availability and recovery services
NOTE: For more information, visit http://www.hp.com/services/carepack.
Please see the following URL regarding Warranty Information For Your HP Products:
http://h18004.www1.hp.com/products/servers/platforms/warranty/index.html.
For additional information regarding Worldwide Limited Warranty and Technical Support, please see the following URL:
ftp://ftp.compaq.com/pub/supportinformation/ejourney/176738.pdf.
NOTE: Certain restrictions and exclusions apply. Consult the Customer Support Center at 1-800-345-1518 for details.
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 8
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Models
ML530T02 X3000-512KB, Processor
1024MB, 1P
Processor System Bus
271243-xx1
Processor Memory
One Intel Xeon 3.0 GHz Processor standard (up to 2 supported)
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
One 600W Hot Plug Power Supply
System Fan
Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Tower
ML530T02 X3000-512KB, Processor
1024MB, 2P
Processor System Bus
271245-xx1
Processor Memory
Two Intel Xeon 3.0 GHz Processor standard
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
Redundant 600W Hot Plug Power Supplies (1+ 1 redundancy)
System Fan
Redundant Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Tower
ML530T02 X2800-512KB, Processor
1024MB, 1P
Processor System Bus
306487-xx1
Processor Memory
One Intel Xeon 2.80 GHz Processor standard (up to 2 supported)
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
One 600W Hot Plug Power Supply
System Fan
Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Tower
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 9
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Models
ML530T02 X2800-512KB, Processor
1024MB, 2P
Processor System Bus
306489-xx1
Processor Memory
Two Intel Xeon 2.80 GHz Processor standard
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
Redundant 600W Hot Plug Power Supplies (1+ 1 redundancy)
System Fan
Redundant Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Tower
ML530T02 X2400-512KB, Processor
1024MB, 1P
Processor System Bus
180285-xx1
Processor Memory
One Intel Xeon 2.40 GHz Processor standard (up to 2 supported)
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
One 600W Hot Plug Power Supply
System Fan
Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Tower
ML530T02 X2400-512KB, Processor
1024MB, 2P
Processor System Bus
226608-xx1
Processor Memory
Two Intel Xeon 2.40 GHz Processors standard
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
Redundant 600W Hot Plug Power Supplies (1+ 1 redundancy)
System Fan
Redundant Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Tower
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 10
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Models
ML530R02 X3000-512KB, Processor
1024MB, 1P
Processor System Bus
271244-xx1
Processor Memory
One Intel Xeon 3.0 GHz Processor standard (up to 2 supported)
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
One 600W Hot Plug Power Supply
System Fan
Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Rack (7U)
ML530R02 X3000-512KB, Processor
1024MB, 2P
Processor System Bus
271246-xx1
Processor Memory
Two Intel Xeon 3.0 GHz Processor standard
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
Redundant 600W Hot Plug Power Supplies (1+ 1 redundancy)
System Fan
Redundant Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Rack (7U)
ML530R02 X2800-512KB, Processor
1024MB, 1P
Processor System Bus
306488-xx1
Processor Memory
One Intel Xeon 2.80 GHz Processor standard (up to 2 supported)
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
One 600W Hot Plug Power Supply
System Fan
Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Rack (7U)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 11
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Models
ML530R02 X2800-512KB, Processor
1024MB, 2P
Processor System Bus
306490-xx1
Processor Memory
Two Intel Xeon 2.80 GHz Processor standard
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
Redundant 600W Hot Plug Power Supplies (1+ 1 redundancy)
System Fan
Redundant Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Rack (7U)
ML530R02 X2400-512KB, Processor
1024MB, 1P
Processor System Bus
180286-xx1
Processor Memory
One Intel Xeon 2.40 GHz Processor standard (up to 2 supported)
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
One 600W Hot Plug Power Supply
System Fan
Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Rack (7U)
ML530R02 X2400-512KB, Processor
1024MB 2P
Processor System Bus
226609-xx1
Processor Memory
Two Intel Xeon 2.40 GHz Processors standard
400 MHz system bus
512-KB level 2 cache per processor
Memory
1024 MB (Standard) 16,384 MB (Maximum) PC1600 Advanced ECC SDRAM; 2:1
interleaved memory
NOTE: Maximum memory achieved using 2048 MB DIMMs.
Network Controller
Embedded Compaq NC3163 Fast Ethernet NIC PCI 10/100 with WOL (Wake On LAN)
Storage Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Hard Drive
None ship standard
Internal Storage
12 1" hot plug hard drive bays standard
Power Supplies
Redundant 600W Hot Plug Power Supplies (1+ 1 redundancy)
System Fan
Redundant Hot Plug System Fans
Drive Cages
Two 6 x 1" Drive Cages standard
Optical Drive
40x or higher IDE CD-ROM Drive
Form Factor
Rack (7U)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 12
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Models
Country Code Key
Tower Code Key
Rack Code Key
XX=00
U.S. English
U.S. English
XX=01
Australia
N/A
XX=03
UK
N/A
XX=04
Germany
N/A
XX=05
France
N/A
XX=37
APD
APD
XX=29
Japan
Japan
XX=42
Europe
Europe
XX=AA
PRC
PRC
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 13
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
ProLiant ML530 G2
Unique Options
ProLiant Essentials
Value Pack Software
Intel Xeon 3.0 GHz/512 KB Processor Option Kit
316898-B21
Intel Xeon 2.80 GHz/512 KB Processor Option Kit
306504-B21
Intel Xeon 2.40 GHz/512 KB Processor Option Kit
191224-B21
512 MB (2 x 256 MB) PC1600 ECC SDRAM Memory Kit
187418-B21
1024 MB (2 x 512 MB) PC1600 ECC SDRAM Memory Kit
187419-B21
2048 MB (2 x 1024 MB) PC1600 ECC SDRAM Memory Kit
187420-B21
4096 MB (2 x 2048 MB) PC1600 ECC SDRAM Memory Kit
187421-B21
ProLiant ML5xx G2 Tower to Rack Conversion Kit
253699-B21
ProLiant ML5xx G2 Rack to Tower Conversion Kit
271258-B21
Rapid Deployment Pack, 1 User, V1.x
NOTE: This license allows 1 server to be managed and deployed via the Deployment Server.
NOTE
267196-B21
Rapid Deployment Pack, 1 User, V1.x (Japan)
NOTE: This license allows 1 server to be managed and deployed via the Deployment Server.
267196-291
Rapid Deployment Pack, 10 Users, V1.x
NOTE: This license allows 10 servers to be managed and deployed via the Deployment Server.
NOTE
269817-B21
Rapid Deployment Pack, 10 Users, V1.x (Japan)
NOTE: This license allows 10 servers to be managed and deployed via the Deployment Server.
NOTE
269817-291
ProLiant Essentials Workload Management Pack 2.0 (Featuring Compaq Resource Partitioning
Manager version 2.0)
303284-B21
ProLiant Essentials Performance Management Pack Flexible License
306697-B21
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs.
Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack
product QuickSpecs for more information.
NOTE: For more information regarding ProLiant Essentials Software, please see the following URL:
http://www.hp.com/servers/proliantessentials.
Software
HP digital asset protection
302316-001
Processor
Intel Xeon 3.0 GHz/512 KB Processor Option Kit
316898-B21
Intel Xeon 2.80 GHz/512 KB Processor Option Kit
306504-B21
Intel Xeon 2.40 GHz/512 KB Processor Option Kit
191224-B21
512MB PC1600 Registered ECC SDRAM Memory Kit (2 x 256 MB)
187418-B21
1024MB PC1600 Registered ECC SDRAM Memory Kit (2 x 512 MB)
187419-B21
2048MB PC1600 Registered ECC SDRAM Memory Kit (2 x 1024 MB)
187420-B21
4096MB PC1600 Registered ECC SDRAM Memory Kit (2 x 2048 MB)
187421-B21
16X DVD-ROM Drive Option Kit (Carbon)
NOTE: This drive is supported in the CD-ROM bay and in the removable media bay.
217053-B21
CD-RW/DVD ROM Combo Drive Option Kit
NOTE: This drive is supported in the CDROM bay and in the removable media bay.
331346-B21
ML5xx Two Bay Hot Plug SCSI Drive Cage
NOTE: The drive cage option kit (PN 244058-B21) has one 1" drive bay and one 1.6" drive bay.
244058-B21
Memory
(DIMMs; 2:1 interleaved)
Optical Drives
Internal Storage
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 14
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
Hard Drives
Ultra320 SCSI – Universal Hot Plug
36.4-GB 10,000 rpm U320 Universal Hard Drive (1")
286713-B22
72.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286714-B22
146.8-GB 10,000 rpm U320 Universal Hard Drive (1")
286716-B22
18.2-GB 15,000 rpm U320 Universal Hard Drive (1")
286775-B22
36.4-GB 15,000 rpm U320 Universal Hard Drive (1")
286776-B22
72.8-GB 15,000 rpm U320 Universal Hard Drive (1")
286778-B22
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives
require an optional U320 Smart Array Controller or U320 SCSI HBA to support U320 transfer rates.
NOTE: Please see the Hard Drive QuickSpecs for Technical Specifications such as capacity, height,
width, interface, transfer rate, seek time, physical configuration, and operating temperature: U320
Hard Drive QS:
http://h18000.www1.hp.com/products/quickspecs/11531_div/11531_div.HTML (Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11531_na/11531_na.HTML
(North America)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 15
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
Storage Controllers
Smart Array 532 Controller
225338-B21
Smart Array 532 Controller (Japan)
225338-291
Smart Array 5302/128 Controller
283552-B21
Smart Array 5302/128 Controller (Japan)
283552-291
Smart Array 6402/128 Controller
273915-B21
256MB DDR, Battery-Backed Cache Upgrade Kit for SA-6400
NOTE: This 256-MB Battery-Backed Cache upgrade kit supports the Smart Array 6400 series
controller only.
273913-B21
Smart Array 5304/256 Controller
283551-B21
Smart Array 5304/256 Controller (Japan)
283551-291
Smart Array 6402/128 Controller
273915-B21
Smart Array 6404/256 Controller
273914-B21
Smart Array 641 Controller
291966-B21
Smart Array 642 Controller
291967-B21
128-MB Cache Module for Smart Array 5302 Controller
153506-B21
RAID ADG Upgrade for Smart Array 5302
288601-B21
Ultra3 Channel Expansion Module for Smart Array 5300 Controller
153507-B21
256-MB Battery-Back Cache Module
NOTE: This 256-MB Battery-Backed Cache Module supports the Smart Array 5300 series controllers,
HP StorageWorks Modular Smart Array 1000 and the HP StorageWorks Modular Smart Array 500.
254786-B21
64 MB Battery Backed Write Cache Enabler
NOTE: This 64 MB BBWC supports the Smart Array 641 Controller and Smart Array 642 Controller.
291969-B21
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
268351-B21
Ultra320 Expansion Module for SA-6402
273911-B21
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
284688-B21
NOTE: Please see the following Controller or SCSI Adapter QuickSpecs for Technical Specifications
such as PCI Bus, PCI Peak Data Transfer Rate, SCSI Protocols supported, SCSI Peak Data Transfer
Rate, Channels, SCSI Ports, Drives supported, Cache, RAID support, and additional information:
http://h18000.www1.hp.com/products/quickspecs/10851_div/10851_div.HTML
(Smart Array 532)
http://h18000.www1.hp.com/products/quickspecs/10640_div/10640_div.HTML
(Smart Array 5300 Series)
http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.HTML (Smart Array 6400
Series)
http://h18000.www1.hp.com/products/quickspecs/11563_div/11563_div.HTML
(Smart Array 641)
http://h18000.www1.hp.com/products/quickspecs/11563_div/11563_div.HTML
(Smart Array 642)
http://h18000.www1.hp.com/products/quickspecs/10429_div/10429_div.HTML
(SCSI Adapter)
http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.HTML
(U320 Adapter)
Communications
HP NC6770 PCI-X Gigabit Server Adapter, 1000-SX
244949-B21
NC7770 PCI-X Gigabit Server Adapter
244948-B21
NC7771 PCI-X Gigabit Server Adapter
290563-B21
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 16
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
Redundant Options
Management Options
Security
Tape Drives
Hot-plug Redundant Fan Kit
NOTE: Included in 2P models.
128284-B21
Hot Plug Redundant Power Supply
NOTE: Included in 2P models.
NOTE
236845-001
Hot Plug Redundant Power Supply (Australia)
NOTE: Included in 2P models.
236845-011
Hot Plug Redundant Power Supply (Int'l)
NOTE: Included in 2P models.
236845-021
Hot Plug Redundant Power Supply (UK)
NOTE: Included in 2P models.
236845-031
Hot Plug Redundant Power Supply (Japan)
NOTE: Included in 2P models.
NOTE
236845-291
Remote Insight Lights-Out Edition II (NA, LA)
227251-001
Remote Insight Lights-Out Edition II (EMEA)
227251-021
Remote Insight Lights-Out Edition II (ROW)
227251-371
HP/Atalla AXL600L SSL Accelerator Card for ProLiant Servers
524545-B21
Compaq AXL300 Accelerator PCI Card for ProLiant Servers
227933-B21
NOTE: In order to install certain tape drives internally, you may need to remove the rails that come
standard on the drives and then re-insert the screws in the mounting holes. Mounting screws are
shipped standard with server.
NOTE: External tape devices, including both tape drives and tape arrays/enclosures, can be directly
connected to the VHDCI SCSI port located on the back of the server. Use of a SCSI adapter to connect
these devices is optional, not required.
Internal, External and Hot Plug DAT 72 Tape Drives
HP StorageWorks DAT 72 Tape Drive for ProLiant, External (Carbon) US
Q1527A
HP StorageWorks DAT 72 Tape Drive for Open Connect, External (Carbon) WW
Q1523A
HP StorageWorks DAT 72 Tape Drive for ProLiant, External (Carbon) Int'l
Q1528A
HP StorageWorks DAT 72 Tape Drive for ProLiant, Internal (Carbon) WW
Q1525A
HP StorageWorks DAT 72 Tape Drive for Open Connect, Internal (Carbon) WW
Q1522A
HP StorageWorks DAT 72 Tape Drive for ProLiant, Internal Hot Plug (Carbon) WW
Q1529A
NOTE: Please see the DAT 72 Tape Drive QuickSpecs for additional options such as adapters,
controllers, and media, and for an up-to-date listing of the latest O/S Support details, please see the
following:
http://h18000.www1.hp.com/products/quickspecs/11597_div/11597_div.HTML (Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11597_na/11597_na.HTML (North America)
Internal, External and Rackmount DLT Tape Drives
HP StorageWorks DLT 80 Tape Drive, External (Carbon) Japan
146197-293
HP StorageWorks DLT 80 Tape Drive, 3U Rackmount (Single Drive) WW
274332-B21
HP StorageWorks DLT 80 Tape Drive, 3U Rackmount (Two Drives) WW
274335-B21
HP StorageWorks DLT 80 Tape Drive, 5U Rackmount (Four Drives) WW
274337-B21
NOTE: Please see the DLT 80 Tape Drive QuickSpecs for additional options such as host bus
adapters, controllers, media, and for an up-to-date listing of the latest O/S Support details, please see
the following:
http://h18006.www1.hp.com/products/quickspecs/10658_div/10658_div.HTML (Worldwide)
http://h18006.www1.hp.com/products/quickspecs/10658_na/10658_na.HTML (North America)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 17
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
Tape Autoloaders
HP StorageWorks 1/8 Autoloader
HP StorageWorks 1/8 Autoloader, Tabletop, Ultrium 230
C9572CB
HP StorageWorks 1/8 Autoloader, Tabletop, DLT VS80
C9264CB
HP StorageWorks 1/8 Autoloader, Rackmount kit
C9268R
NOTE: Required to install the unit in a standard 19-inch rack; includes rails and rackmount
instructions.
SSL1016 Tape Autoloader
SSL1016 DLT1 tape autoloader (includes two 8-cartridge magazines and a barcode reader)
330815-B21
NOTE: Please see the SSL1016 DLT1 tape autoloader Quick Specs for additional information:
http://www5.compaq.com/products/quickspecs/11626_na/11626_na.HTML
(North America)
http://www5.compaq.com/products/quickspecs/11626_div/11626_div.HTML (Worldwide)
SSL1016 SDLT160/320 tape autoloader (includes 2 8-cartridge magazines and a barcode reader)
330816-B21
NOTE: Please see the SSL1016 SDLT160/320 tape autoloader Quick Specs for additional
information:
http://www5.compaq.com/products/quickspecs/10609_na/10609_na.HTML
(North America)
http://www5.compaq.com/products/quickspecs/10609_div/10609_div.HTML (Worldwide)
SSL 1016 SDLT160/320 drive upgrade kit
330818-B21
NOTE: Please see the SSL1016 SDLT160/320 tape autoloader Quick Specs for additional
information:
http://www5.compaq.com/products/quickspecs/10609_na/10609_na.HTML
(North America) http://www5.compaq.com/products/quickspecs/10609_div/10609_div.HTML
(Worldwide)
SSL1016 Ultrium 460 tape autoloader
330821-B21
NOTE: Please see the SSL1016 Ultrium 460 tape autoloader Quick Specs for additional
information:
http://h18006.www1.hp.com/products/quickspecs/11704_na/11704_na.HTML
(North America) http://h18006.www1.hp.com/products/quickspecs/11704_div/11704_div.HTML
(Worldwide)
Tape Libraries
StorageWorks MSL6000 and MSL5000 Departmental Midrange Tape Libraries
MSL6060L1 - LTO Ultrium 1 based mainstream library up to 4 drives and 60 slots
MSL6060, 0 DRV, Ultrium 460, RM Library
331196-B23
MSL6060, 2 DRV, Ultrium 460, RM Library
331195-B21
MSL6060, 2 DRV, Ultrium 460, embedded Fibre, RM Library
331196-B22
MSL6060, 2 DRV, Ultrium 460, LVDS, TT Lib
331195-B21
NOTE: Please see the StorageWorks MSL6060 LTO Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11608_na/11608_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/11608_div/11608_div.HTML
(Worldwide)
MSL5060L1 - LTO Ultrium 1 based mainstream library up to 4 drives and 60 slots
MSL5060L1, 0 DRV, Ultrium 230, RM Library
301899-B21
MSL5060L1, 2 DRV, Ultrium 230, RM Library
301899-B22
MSL5060L1, 2 DRV, Ultrium 230, embedded Fibre, RM Library
301899-B23
MSL5060, 2 DRV, Ultrium 230, TT Library
301900-B21
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 18
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11438_na/11438_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/11438_div/11438_div.HTML
(Worldwide)
MSL5052S2 - SDLT160 based mainstream library up to 4 drives and 52 slots
MSL5052S2, 0 DRV, SDLT 160/320, RM Library
255102-B21
MSL5052S2, 2 DRV, SDLT 160/320, RM Library
293474-B21
MSL5052S2, 2 DRV, SDLT 160/320, RM Library with embedded Fibre
293474-B24
MSL5052S2, 2 DRV, SDLT 160/320, TT Library
293476-B22
NOTE: Please see the StorageWorks MSL5052S2 Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11442_na/11442_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11442_div/11442_div.HTML (Worldwide)
MSL6030 - LTO Ultrium 1 based mainstream library up to 4 drives and 60 slots
MSL6030, 0 DRV, RM Library
330731-B21
MSL6030, 1 DRV, LTO Ultrium 460, RM Library
330731-B22
MSL6030, 2 DRV, LTO Ultrium 460, RM Library
330731-B23
MSL6030, 1 DRV, LTO Ultrium 460, embedded Fibre, RM Library
330731-B24
MSL 6030, 2 DRV, LTO Ultrium 460, embedded Fibre, RM Library
330731-B25
MSL6030, 1 DRV, LTO Ultrium 460, LVDS TT Library
330788-B21
MSL6030, 2 DRV, LTO Ultrium 460, LVDS TT Library
330788-B22
NOTE: Please see the StorageWorks MSL6030 LTO Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11625_na/11625_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11625_div/11625_div.HTML (Worldwide)
MSL5030L1 - LTO Ultrium 1 mid-range library up to 2 drives and 30 slots
MSL5030L1, 0 DRV, RM Library
301897-B21
MSL5030L1, 1 DRV, LTO Ultrium 230, RM Library
301897-B22
MSL5030L1, 2 DRV, LTO Ultrium 230, RM Library
301897-B23
MSL5030L1, 1 DRV, LTO Ultrium 230, embedded Fibre, RM Library
301897-B24
MSL 5030L1, 2 DRV, LTO Ultrium 230, embedded Fibre, RM Library
301897-B25
MSL5030, 1 DRV, LTO Ultrium 230, TT Library
301898-B21
MSL5030, 2 DRV, LTO Ultrium 230, TT Library
301898-B22
NOTE: Please see the StorageWorks MSL5030 LTO Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11439_na/11439_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11439_div/11439_div.HTML (Worldwide)
MSL5026S2 - SDLT160 based mid-range library up to 2 drives and 26 slots
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 19
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
MSL5026S2, 0 DRV, SDLT 160/320, RM Library
293472-B21
MSL5026S2, 1 DRV, SDLT 160/320, RM Library
293472-B22
MSL5026S2, 2 DRV, SDLT 160/320, RM Library
293472-B23
MSL5026S2, 1 DRV, SDLT 160/320, RM Library with embedded Fibre
293472-B24
MSL5026S2, 2 DRV, SDLT 160/320, RM Library with embedded Fibre
293472-B25
MSL5026S2, 1 DRV, SDLT 160/320, TT Library
293473-B21
MSL5026S2, 2 DRV, SDLT 160/320, TT Library
293473-B22
NOTE: Please see the StorageWorks MSL5026SL Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11453_na/11453_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11453_div/11453_div.HTML (Worldwide)
MSL5026SL Graphite - SDLT110 based mid-range library up to 2 drives and 26 slots
MSL5026SL, 1 DRV SDLT RM, graphite
302512-B21
MSL5026SL, 2 DRV SDLT RM, graphite
302512-B22
MSL5026SL, 1 DRV SDLT TT Library, graphite
302511-B21
MSL5026SL, 2 DRV SDLT TT Library, graphite
302511-B22
NOTE: Please see the StorageWorks MSL5026SL Graphite Library QuickSpecs for additional
information including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed
for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11440_na/11440_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/11440_div/11440_div.HTML
(Worldwide)
MSL5026DLX- 40/80GB DLT based mid-range library up to 2 drives and 26 slots
MSL5026DLX, 1 40/80GB DLT, LVD, RM
231891-B21
MSL5026DLX, 2 40/80GB DLT, LVD, RM
231891-B22
MSL5026DLX, 1 40/80GB DLT, LVD, TT Library
231821-B21
MSL5026DLX, 2 40/80GB DLT, LVD, TT Library
231821-B22
NOTE: Please see the StorageWorks MSL5026DLX Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/10860_na/10860_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/10860_div/10860_div.HTML
(Worldwide)
MSL6000 and MSL5000 Add-on drives & accessories
MSL5000 SDLT 160/320 Upgrade DRV (MSL5052S2 & MSL5026S2 only)
293475-B21
MSL5000 LTO Ultrium 1 Upgrade DRV (MSL5060L1 & MSL5030L1 only)
301901-B21
MSL5000 SDLT 110/220 Upgrade DRV
231823-B22
MSL5000 40/80GB DLT Upgrade DRV
231823-B21
MSL5000 Dual Magazine LTO (2 X 15 slot magazines)
301902-B21
MSL5000 Dual Magazine DLT (2 X 13 slot magazines)
232136-B21
MSL Universal Pass-Through mechanism
304825-B21
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 20
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
Magento-Optical
Jukeboxes
Tape Automation
MSL Tape Library Rack Mount Kit
304826-B21
MSL5026 Rack Mount Kit, ProLiant Servers
231894-B22
MSL e1200-160 External Fibre Channel
330728-B21
MSL5026, 5U Pass-Through extender (required one for each unit connected to the stack, for third and
additional units) - for MSL5026 & MSL5030
231824-B22
MSL5052, 10U Pass-Through Extender (required one for each unit connected to the stack, for third
and additional units) - for MSL5052 & MSL5060
231824-B23
MSL6000, Utrium 460 Drive Upgrade Kit
330729-B21
Midrange Jukebox
StorageWorks Optical 300mx, 2 drive, 32 slot jukebox
C1150M
StorageWorks Optical 600mx, 4 drive, 64 slot jukebox
C1160M
StorageWorks Optical 700mx, 2 drive, 76 slot jukebox
C1170M
SSL2020 – AIT50 based library with up to 2 drives and 20 slots
SSL2020 AIT Mini-Library 1 drive, 20 slot Table Top
175195-B21
SSL2020 AIT Mini-Library 2 drive, 20 slot Table Top
175195-B22
SSL2020 AIT Mini-Library 1 drive, 20 slot Rackmount
175196-B21
SSL2020 AIT Mini-Library 2 drive, 20 slot Rackmount
175196-B22
SSL2020 AIT Library Pass Thru with Transport
175312-B21
Add-on drives and accessories
SSL2020 AIT Library Pass Thru Extender
175312-B22
AIT 50GB Drive Add-On LVD Drive for SSL2020 AIT Library
175197-B21
19 Slot Magazine for SSL2020 AIT Library
175198-B21
AIT 50-GB Data Cassette (5 pack)
152841-001
AIT Cleaning Cassette
402374-B21
NOTE: Please see the SSL2020 Automated AIT Tape Library Solution QuickSpecs for additional
information including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed
for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/10580_na/10580_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/10580_div/10580_div.HTML
(Worldwide)
MSL5060L1 – LTO Ultrium 1 based departmental library up to 4 drives and 60 slots
MSL5060L1, 0 DRV LTO1 RM Library
301899-B21
MSL5060L1, 2 DRV LTO1 RM Library
301899-B22
MSL5060L1, 2 DRV LTO1 TT Library
301900-B21
MSL5060L1FC, 2 DRV LTO1 RM-with integrated FC router
301899-B23
NOTE: Please see the StorageWorks MSL5060 LTO Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11438_na/11438_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/11438_div/11438_div.HTML
(Worldwide)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 21
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
MSL5052S2 – SDLT160 based departmental library up to 4 drives and 52 slots
MSL5052S2, RM 0 DRV SDLT ALL
255102-B21
MSL5052S2, 2 DRV SDLT2 TT LIB
293476-B21
MSL5052S2, 2 DRV SDLT2 RM LIB
293474-B21
MSL5052S2FC 2 DRV SDLT2 RM- with integrated FC router
293474-B24
NOTE: Please see the StorageWorks MSL5052S2 Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11442_na/11442_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11442_div/11442_div.HTML
(Worldwide)
StorageWorks MSL5000 mid-range libraries
MSL5030L1 – LTO Ultrium 1 mid-range library up to 2 drives and 30 slots
MSL5030L1, 0 DRV LTO1 RM Library
301897-B21
MSL5030L1, 1 DRV LTO1 RM Library
301897-B22
MSL5030L1, 2 DRV LTO1 RM Library
301897-B23
MSL5030L1, 1 DRV LTO1 TT Library
301898-B21
MSL5030L1, 2 DRV LTO1 TT Library
301898-B22
MSL5030L1FC, 1 DRV LTO1 RM- with integrated FC router
301897-B24
MSL5030L1FC, 2 DRV LTO1 RM- with integrated FC router
293472-B25
NOTE: Please see the StorageWorks MSL5030 LTO Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11439_na/11439_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11439_div/11439_div.HTML
(Worldwide)
MSL5026S2 – SDLT160 based mid-range library up to 2 drives and 26 slots
MSL5026S2, 0 DRV SDLT2 RM Library
293472-B21
MSL5026S2, 1 DRV SDLT2 RM Library
293472-B22
MSL5026S2, 2 DRV SDLT2 RM Library
293472-B23
MSL5026S2, 1 DRV SDLT2 TT Library
293473-B21
MSL5026S2, 2 DRV SDLT2 TT Library
293473-B22
MSL5026S2FC, 1 DRV SDLT2 RM- with integrated FC router
293472-B24
MSL5026S2FC, 2 DRV SDLT2 RM- with integrated FC router
293472-B25
NOTE: Please see the StorageWorks MSL5026SL Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11453_na/11453_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/11453_div/11453_div.HTML
(Worldwide)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 22
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
MSL5026SL Graphite – SDLT110 based mid-range library up to 2 drives and 26 slots
MSL5026SL, 1 DRV SDLT TT, graphite
302511-B21
MSL5026SL, 2 DRV SDLT TT, graphite
302511-B22
MSL5026SL, 1 DRV SDLT RM, graphite
302512-B21
MSL5026SL, 2 DRV SDLT RM, graphite
302512-B22
NOTE: Please see the StorageWorks MSL5026SL Graphite Library QuickSpecs for additional
information including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed
for a complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11440_na/11440_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11440_div/11440_div.HTML
(Worldwide)
MSL5026SL Opal – SDLT110 based mid-range library up to 2 drives and 26 slots
MSL5026, 0 DR, LVD, RM
DA - 11359
231979-B21
Worldwide — Version 40 — January 15, 2004
Page 23
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
MSL5026DLX– 40/80GB DLT based mid-range library up to 2 drives and 26 slots
MSL5026DLX, 1 40/80GB DLT, LVD, TT
231821-B21
MSL5026DLX, 2 40/80GB DLT, LVD, TT
231821-B22
MSL5026DLX, 1 40/80GB DLT, LVD, RM
231891-B21
MSL5026DLX, 2 40/80GB DLT, LVD, RM
231891-B22
NOTE: Please see the StorageWorks MSL5026DLX Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/10860_na/10860_na.HTML
(North America) http://h18000.www1.hp.com/products/quickspecs/10860_div/10860_div.HTML
(Worldwide)
MSL5000 Add-on drives & accessories
MSL5000 SDLT 160/320 Upgrade DRV (MSL5052S2 & MSL5026S2 only)
293475-B21
MSL5000 LTO Ultrium 1 Upgrade DRV (MSL5060L1 & MSL5030L1 only)
301901-B21
MSL5000 SDLT 110/220 Upgrade DRV
231823-B22
MSL5000 40/80GB DLT Upgrade DRV
231823-B21
MSL5000 Dual Magazine LTO (2 X 15 slot magazines)
301902-B21
MSL5000 Dual Magazine DLT (2 X 13 slot magazines)
232136-B21
MSL5000 pass through mechanism 10 U (required for multi-unit scalability)
231824-B21
MSL5000, Pass through mechanism 10U (includes elevator mechanism and router, required to
connect first two units in a stack)
231824-B21
MSL5026, 5U Pass through extender (required one for each unit connected to the stack, for third and
additional units) – for MSL5026 & MSL5030
231824-B22
MSL5052, 10U Pass-Through Extender (required one for each unit connected to the stack, for third
and additional units) – for MSL5052 & MSL5060
231824-B23
MSL6000 Libraries
MSL6030 LTO Library
MSL6030, Rackmount, 0 Drive Library
330731-B21
MSL6030, Rackmount, 1 Drive, LTO2 Library
330731-B22
MSL6030, Rackmount, 2 Drive, LTO2 Library
330731-B23
MSL6030, Rackmount, embedded Fibre, 1 Drive, LTO2 Library
330731-B24
MSL6030, Rackmount, embedded Fibre, 2 Drive, LTO2 Library
330731-B25
MSL6030, Tabletop, 1 Drive, LTO2 Library
330788-B21
MSL6030, Tabletop, 2 Drive, LTO2 Library
330788-B22
NOTE: Please see the StorageWorks MSL6030 LTO Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11625_na/11625_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11625_div/11625_div.HTML
(Worldwide)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 24
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
MSL6060 LTO Library
MSL6060, Rackmount, 0 Drive Library
331196-B23
MSL6060, Rackmount, 2 Drive, LTO2 Library
331196-B21
MSL6060, Rackmount, embedded Fibre, 2 Drive, LTO2 Library
331196-B22
MSL6060, Tabletop, 2 Drive, LTO2 Library
331195-B21
NOTE: Please see the StorageWorks MSL6030 LTO Library QuickSpecs for additional information
including Upgrade Kits, Accessories, and SCSI Cable Kits and additional options needed for a
complete solution at:
http://h18000.www1.hp.com/products/quickspecs/11608_na/11608_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11608_div/11608_div.HTML (Worldwide)
MSL6000 series Libraries Options
External Storage – Tower
& Rack
MSL Ultrium 460 upgrade drive in hot plug canister
330729-B21
MSL Universal passthrough mechanism
304825-B21
MSL 10U passthrough extender
231824-B23
HP StorageWorks Modular Smart Array 30 SB
302969-B21
HP StorageWorks Modular Smart Array 30 DB
302970-B21
StorageWorks Enclosure Model 4314T (tower)
190210-001
StorageWorks Enclosure Model 4314T (tower) (Int'l)
190210-B31
StorageWorks Enclosure Model 4314T (tower) (Japan)
190210-291
StorageWorks Enclosure Model 4314R (rack-mountable)
190209-001
StorageWorks Enclosure Model 4314R (rack-mountable) (Int'l)
190209-B31
StorageWorks Enclosure Model 4314R (rack-mountable) (Japan)
190209-291
StorageWorks Enclosure Model 4354R (rack-mountable)
190211-001
StorageWorks Enclosure Model 4354R (rack-mountable) (Int'l)
190211-B31
StorageWorks Enclosure Model 4354R (rack-mountable) (Japan)
190211-291
NOTE: The StorageWorks Enclosure 4300 Family support the Wide Ultra2/Ultra3 1" Hot Plug Hard
Drives.
Redundant Power Supply Option
338296-B21
Ultra3 Single Bus I/O Module Option
190212-B21
Ultra3 Dual Bus I/O Module Option
190213-B21
StorageWorks Enclosure Tower to Rack Conversion Kit
150213-B21
Ultra320 Dual Bus I/0 Module for Modular Smart Array 30
287483-B21
Ultra320 Single Bus I/0 Module for Modular Smart Array 30
287484-B21
HP StorageWorks Modular HP StorageWorks Modular Smart Array 1000
Smart Array 1000
Modular Smart Array 1000 Controller
201723-B22
218231-B22
Modular Smart Array Fibre Channel I/O Module
218960-B21
Modular Smart Array 1000 Fibre Channel Adapter (FCA) 2101
245299-B21
Modular Smart Array hub 2/3
286763-B21
NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options and
configuration information at
http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML (Worldwide)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 25
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
StorageWorks Options
StorageWorks SAN Switch 2/8-EL
322120-B21
StorageWorks SAN Switch 2/16
322118-B21
UPS Power Cord Matrix
Please see the UPS Power Cord Matrix for cable descriptions, requirements, and specifications for UPS
units:
ftp://ftp.compaq.com/pub/products/servers/proliantstorage/power-protection/powercordmatrix.pdf.
Uninterruptible Power
Systems – Tower Supply
Compaq UPS T1000 XR (1000 VA, 700 Watts), Low Voltage (NA)
204155-001
Compaq UPS T1000 XR (1000 VA, 700 Watts), High Voltage (Int'l)
204155-B31
UPS T1000 XR (1000VA, 700Watts) 100 VAC (JPN)
312803-291
Compaq UPS T1500 XR (1440 VA, 1050 Watts) (NA)
204155-002
Compaq UPS T1500 XR (1500 VA, 1050 Watts) (Int'l)
204155-B32
Compaq UPS T1500 XR (1500 VA, 1050 Watts) (Japan)
204155-292
Compaq UPS T2200 XR (1920 VA, 1600 Watts) Low Voltage (NA)
204451-001
Compaq UPS T2200 XR (2200 VA, 1600 Watts) High Voltage (NA)
204451-002
Compaq UPS T2200 XR (2200 VA, 1600 Watts) (Int'l)
204451-B31
Compaq UPS T2200 XR (2200 VA, 1600 Watts) (Japan)
204451-291
Compaq UPS R1500 XR (100 to 127) (NA)
204404-001
Compaq UPS R1500 XR (208 to 480) (Int'l)
204404-B31
Compaq UPS R1500 XR (100 to 127) (Japan)
204404-291
Compaq UPS R3000 XR (120V) (NA)
192186-001
Compaq UPS R3000 XR (208V) (NA)
192186-002
Compaq UPS R3000 XR (100V) (Japan)
192186-291
Compaq UPS R3000 XR (208V) (Japan) Compaq UPS R3000 XR (200V) (Japan)
192186-292
Compaq UPS R3000 XR (230V) (Int'l - detachable cord)
192186-B31
Compaq UPS R3000 XR (230V) (16A IEC309 Plug)
192186-B32
Uninterruptible Power
Systems – Rack
Compaq UPS R3000 XR (230V) (16A CEE 7/7 SCHUKO Plug)
192186-B33
Compaq UPS R3000 XR (230V) (16A BS-546 Plug)
192186-AR1
Rack-Mountable UPS R6000 (208V) (NA)
347207-001
Rack-Mountable UPS R6000 (230V) (Int'l)
347207-B31
Rack-Mountable UPS R6000 (200V) (Japan)
347207-291
UPS R12000 XR N+ x (200-240V) (WW-hardwired)
207552-B22
NOTE: UPS R6000 has a hardwired input; and the UPS R12000 XR has a hardwired input and
output connection.
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 26
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
UPS Options
Modular PDUs 1U/0U
(Up to 32 outlets)
SNMP Serial Port Card
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA
NOTE
192189-B21
Six Port Card
NOTE: Supports tower and rack UPS XR models ranging from 1000 – 3000VA.
NOTE
192185-B21
High to Low Voltage Transformer (250VA)
NOTE: Supports R6000 UPS series only. 2.5A @ 125 Volts max output across two NEMA 5-15.
NOTE
388643-B21
Extended Runtime Module, T1000 XR
218967-B21
Extended Runtime Module, T1500 XR/T2200 XR
218969-B21
Extended Runtime Module, R1500 XR
NOTE:
NOTE 2U each, two ERM maximum.
218971-B21
Extended Runtime Module, R3000 XR
NOTE: 2U each, one ERM maximum.
NOTE
192188-B21
Extended Runtime Module, R6000
NOTE: 3U each, two ERM maximum.
NOTE
347224-B21
Extended Runtime Module, R12000 XR, 4U each, two ERMs maximum
217800-B21
R12000 XR BackPlate Receptacle Kit, (2) L6-30R (NA)
NOTE: The R12000 XR BackPlate Kit has a hardwired input.
325361-001
R12000 XR BackPlate Receptacle Kit, (2) IEC-309R (WW)
NOTE: The R12000 XR BackPlate Kit has a hardwired input.
325361-B21
SNMP-EN Adapter
NOTE: Supports R6000 UPS series only.
NOTE
347225-B21
Multi-Server UPS Card
NOTE: Supports R6000 UPS series only.
NOTE
123508-B21
Scalable UPS Card
NOTE: Supports R6000 UPS series only.
NOTE
123509-B21
Cable, 1xC13-C14, Y-Cable (WW)
310782-B21
Cable, 1xIECC19-C20, 16A, 2.5m (WW)
295633-B22
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan)
252663-D71
NOTE: The above mPDU may also be used to connect to the low volt model of the UPS R3000 XR.
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC) (NA, Japan)
252663-D72
NOTE: L6-30 input.
HP Modular Power Distribution Units (mPDU), High Volt Model, 32A (200-240 VAC) (Int'l)
252663-B31
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC) (WW)
252663-B21
NOTE: The 40A model has a hardwired input.
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC) (WW)
252663-B24
NOTE: This PDU has a detachable input power cord and allows for adaptability to country specific
power requirements. This model may also be used with the high volt UPSs R3000 XR and R6000.
Cable P/N 340653-001 required if connecting to UPS R3000 XR (192186-002 NA -High Volt model
only).
NOTE: Please see the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs)
QuickSpecs for additional options including shorter jumper cables and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML
(North America)
http://h18000.www1.hp.com/products/quickspecs/11041_div/11041_div.HTML (Worldwide)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 27
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
PDU Options
1U PDU Mounting Brackets Kit
215852-B21
NOTE: The 1U PDU Mounting Brackets are required when mounting PDUs PN 207590-xxx series in
1U configurations.
Third Party Modular PDU Mounting Kit
310777-B21
NOTE: This kit allows you to mount the Modular PDUs in racks other than the 9000/10000 Series
racks (any racks using the standard 19² rail). For more details please refer the Modular PDU
QuickSpecs.
USB Options
USB Optical Scroll Mouse (Carbonite)
DD441B
USB 1.44-MB External Diskette Drive (Carbonite)
DC141B
USB Easy Access Keyboard (Carbonite/Silver)
DC168B#
USB Easy Access Keyboard (Carbonite/Silver) Country Key Code
Dash #
Description
Dash #
Description
A2M
ICELAND
ABT
HE
AB0
TAWA
ABU
UK
AB1
KOR
ABV
ARA
AB2
PRC
ABX
FIN
AB6
FRA
ABY
DEN
AB7
GRK
ABZ
ITL
AB8
TURK
AC0
BEL
AB9
PORT
AC4
BRZ
ABA
US
ACB
RUSS
ABB
EURO
AKB
CZE
ABC
FCAN
AKC
HUNG
ABD
GR
AKD
POL
ABE
SP
AKL
THAI
ABF
FR
AKN
BHCSY
ABH
NL
AKR
SLOV
ABJ
Japan
ARK
ICELAND
ABM
LA
B15
KAZ
ABN
NOR
UUZ
SWISS
ABS
SW
Rack Builder
Please see the Rack Builder for configuration assistance at http://www.compaq.com/rackbuilder/.
Rack Conversion Kit
ProLiant ML5xx G2 Tower to Rack Conversion Kit
253699-B21
ProLiant ML5xx G2 Rack to Tower Conversion Kit
271258-B21
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 28
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
HP Rack 10000 Series
(Graphite Metallic)
HP Rack S10614 (14U) Rack Cabinet - Shock Pallet
292302-B22
HP Rack 10842 (42U, 800mm wide) – Pallet
257415-B21
HP Rack 10842 (42U, 800mm wide) – Shock Pallet
257415-B22
HP Rack 10647 (47U) – Pallet
245160-B21
HP Rack 10647 (47U) – Crated
245160-B23
HP Rack 10642 (42U) – Pallet
245161-B21
HP Rack 10642 (42U) – Shock Pallet
245161-B22
HP Rack 10642 (42U) – Crated
245161-B23
HP Rack 10636 (36U) – Pallet
245162-B21
HP Rack 10636 (36U) – Shock Pallet
245162-B22
HP Rack 10636 (36U) – Crated
245162-B23
HP Rack 10622 (22U) – Pallet
245163-B21
HP Rack 10622 (22U) – Shock Pallet
245163-B22
HP Rack 10622 (22U) – Crated
245163-B23
NOTE: -B21 (pallet) used to ship empty racks shipped on a truck
-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and
Channels)
-B23 (crated) used for air shipments of empty racks
NOTE: Please see the Rack 10000 QuickSpecs for Technical Specifications such as height, width,
depth, weight, and color:
http://h18000.www1.hp.com/products/quickspecs/10995_div/10995_div.HTML
(Worldwide)
http://h18000.www1.hp.com/products/quickspecs/10995_na/10995_na.HTML
(North America)
NOTE: For additional information regarding Rack Cabinets, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/racks/index.html.
Rack Options for HP
Rack 10000 Series
Rack Blanking Panels – Graphite (Multi)
253214-B26
NOTE: Contains one each of 1U, 2U, 4U and 8U.
Rack Blanking Panels – Graphite (1U)
253214-B21
NOTE: The Rack Blanking Panels (PN 253214-B21) contains 10 each of (1U).
Rack Blanking Panels – Graphite (2U)
253214-B22
NOTE: The Rack Blanking Panels (PN 253214-B21) contains 10 each of (2U).
Rack Blanking Panels – Graphite (3U)
253214-B23
NOTE: The Rack Blanking Panels (PN 253214-B21) contains 10 each of (3U).
Rack Blanking Panels – Graphite (4U)
253214-B24
NOTE: The Rack Blanking Panels (PN 253214-B21) contains 10 each of (4U).
Rack Blanking Panels – Graphite (5U)
253214-B25
NOTE: The Rack Blanking Panels (PN 253214-B21) contains 10 each of (5U).
800mm Wide Stabilizer Kit (Graphite)
255488-B21
NOTE: Supported by the Rack 10842 cabinet only.
600mm Stabilizer Kit – Graphite
246107-B21
Baying Kit for Rack 10000 series (Carbon)
248929-B21
42U Side Panel – Graphite Metallic
246099-B21
110V Fan Kit (Graphite)
257413-B21
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 5-15P.
220V Fan Kit (Graphite)
257414-B21
NOTE: Roof Mount Includes power cord with IEC320-C13 to Nema 6-15P.
36U Side Panel – Graphite Metallic
246102-B21
47U Side Panel – Graphite Metallic
255486-B21
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 29
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
9000/10000 Series Offset Baying Kit (42U)
248931-B21
NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together.
Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of
the two racks.
NOTE: For additional information regarding Rack Options, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html.
Ballast Option Kit
120672-B21
9000/10000 Series Offset Baying Kit (42U)
248931-B21
NOTE: This kit can be used to connect 9000 and 10000 series racks of the same U height together.
Kit contents include hardware for connecting racks and a panel to cover the 100mm gap at the rear of
the two racks.
NOTE: For additional information regarding Rack Cabinets, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html
Rack Rail Adapter Kit (25" depth)
120675-B21
100 kg Sliding Shelf
234672-B21
Monitor/Utility Shelf - Graphite
253449-B21
Depth Adjustable Fixed Rail
332558-B21
Cable Management D-Rings Kit
168233-B21
Console Management Controller (CMC) Option Kit
203039-B21
Console Management Controller (CMC) Sensors Option Kit
203039-B22
Console Management Controller (CMC) Locking Option Kit
203039-B23
Console Management Controller (CMC) Smoke Sensors Option Kit
203039-B24
KVM USB Interface Adapter
336047-B21
Server Console Switch 1 x 4 port (100-230 VAC)
400336-001
Server Console Switch, 0 x 1 x 8 port
336044-B21
Server Console Switch, 0 x 2 x 16 port
336045-B21
Server Console Switch 1 x 4 port (100-230 VAC) (Int’l)
400336-B31
Server Console Switch 1 x 4 port (100-230 VAC) (Japan)
400336-291
IP Console Switch Box, 1 x 1 x 16
262585-B21
IP Console Switch Box, 3 x 1 x 16
262586-B21
IP Console Interface Adapter, 8 pack
262587-B21
IP Console Interface Adapter, 1 pack
262588-B21
IP Console Expansion Module
262589-B21
CPU to Server Console Cable, 12’
110936-B21
CPU to Server Console Cable, 3’
110936-B24
CPU to Server Console Cable, 7’
110936-B25
IP CAT5 Cable 3’, 4 pack
263474-B21
IP CAT5 Cable 6’, 8 pack
263474-B22
IP CAT5 Cable 12’, 8 pack
263474-B23
IP CAT5 Cable 20’, 4 pack
263474-B24
IP CAT5 Cable 40’, 1 pack
263474-B25
Switch Box Connector Kit (115V)
144007-001
Switch Box Connector Kit (230V)
144007-002
Switch Box Connector Kit (high voltage) (Int'l)
144007-B33
TFT5600 Rack Keyboard Monitor
221546-xx1
Country Code Key (for TFT5600 RKM Rack Keyboard Monitor (PN 221546-xx1))
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 30
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
XX = 001
US
XX = 091
Norway
XX = 031
UK
XX = 101
Sweden/Finland
XX = 041
Germany
XX = 111
Switzerland
XX = 051
France
XX = 131
Portugal
XX = 061
Italy
XX = 181
Belgium
XX = 071
Spain
XX = 291
Japan
XX = 081
Denmark
XX = B31
International
Local Access Cable Kit
232985-B21
1U Rack Keyboard & Drawer (Carbon)
NOTE: The 1U Rack Keyboard & Drawer (PN 257054-xx1) is to be used with the Keyboards for Racks
with Trackball (PN 158649-xxx).
257054-xx1
Country Code Key (for 1U Rack Keyboard & Drawer (PN 257054-xx1))
XX = 001
US
XX = 091
Norway
XX = 031
UK
XX = 101
Sweden/Finland
XX = 041
Germany
XX = 111
Switzerland
XX = 051
France
XX = 131
Portugal
XX = 061
Italy
XX = 181
Belgium
XX = 071
Spain
XX = 291
Japan
XX = 081
Denmark
XX = B31
International
Input Device Adjustable Rails
287139-B21
NOTE: Input Device Adjustable Rails (287139-B21) are for use with the TFT5110R, TFT5600RKM and
integrated keyboard/drawer which is used in mounting into third party racks.
Input Device Telco Rail
287138-B21
NOTE: Input Device Adjustable Rails (287138-B21) are for use ONLY with the TFT5110R,
TFT5600RKM and integrated keyboard/drawer which is used in mounting into third party racks.
Keyboard/Monitor/Mouse extension cables
169989-001
NOTE: For additional information regarding Rack Options, please see the following URL:
http://h18000.www1.hp.com/products/servers/proliantstorage/rack-options/index.html.
Rack Options for Third
Party Cabinet Racks
Third Party Rack Kit
NOTE: This supports the ProLiant ML530 Generation 2 (G2).
DA - 11359
Worldwide — Version 40 — January 15, 2004
274739-B21
Page 31
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
HP Factory Express
Factory Installation, Racking, and Customization Services
Factory Express Server Configuration Level 1
293355-888
NOTE:
NOTE Free Installation of HP Options - Installation of HP Options memory, NICs, hard drives,
controllers, processors, I/O cards, pre-install standard OEM OS image, and tape drives. Installation
fees will apply to all non-HP certified hardware and asset tags.
Factory Express Server Configuration Level 2
266326-888
NOTE:
NOTE Includes Level 1 Customer Intent of a ProLiant server and options configuration, OS
installation, custom image download, IP addressing, network setting, and custom packaging.
Customer unique requirements (quick restore creation, cd duplication, test reports, real-time reporting
of server MAC address, password, and RILOE). Customer access, validation and control through VPN
(price/server).
Factory Express Rack Integration Level 3 with 1 – 3 servers or storage enclosures
325736-888
Factory Express Rack Integration Level 3 with 4 – 9 servers or storage enclosures
232539-888
Factory Express Rack Integration Level 3 with 10 or more servers or storage enclosures
325735-888
NOTE: Includes Level 1 Customer Intent for standard mounted servers and storage units plus
standard cable mgmt, RAID configuration, servers & storage, power distribution, networking gear and
accessories (price/rack).
NOTE:
NOTE Available on ProLiant rack models only.
Factory Express Rack Integration Level 4 with 1 – 3 servers or storage enclosures
325734-888
Factory Express Rack Integration Level 4 with 4 – 9 servers or storage enclosures
232540-888
Factory Express Rack Integration Level 4 with 10 or more servers or storage enclosures
325733-888
NOTE: Includes Level 2 Customer Intent plus customer defined cable management and naming
convention, customer furnished image download, IP addressing, cluster configurations (SQL, External
storage RAID). Quick restore creation, cd duplication, test reports, real-time reporting of server MAC
address, password, RILOE). Customer access and validation through VPN (price/rack).
NOTE:
NOTE Available on ProLiant rack models only.
Factory Express Rack Integration Level 5 with 1 – 3 servers or storage enclosures
325732-888
Factory Express Rack Integration Level 5 with 4 – 9 servers or storage enclosures
232541-888
Factory Express Rack Integration Level 5 with 10 or more servers or storage enclosures
325731-888
NOTE:
NOTE Includes Level 4 Customer Intent plus Custom SW layering and extended test, Customer
access, validation and control through VPN, Clustered racks with networking gear and / or external
storage array, Start-up installation services custom quote. (price/rack).
NOTE:
NOTE Available on ProLiant rack models only.
NOTE:
NOTE Factory Express Engineered Solution Level 6 is a custom solutions available through Factory
Express. Please contact your local reseller or Account Manager.
Service and Support
Offerings (HP Care Pack
Services)
Hardware Services 4-Hour On-site Service
4-Hour On-site Service, 9-Hour x 5-Day Coverage, 3 Years (2-5-2 Part Number for Canada)
FP-MI4HR-36
4-Hour On-site Service, 9-Hour x 5-Day Coverage, 3 Years (6-3 Part Number for US)
401783-002
4-Hour On-site Service, 9-Hour x 5-Day Coverage, 3 Years (6-3 Part Number for EMEA)
324418-002
4-Hour On-site Service, 24 Hour x 7 Day Coverage, 3 Years (6-3 Part Number for US)
4-Hour On-site Service, 24 Hour x 7 Day Coverage, 3 Years (2-5-2 for Canada)
4-Hour On-site Service, 24-Hour x 7-Day Coverage, 3 Years (2-5-2 Part Number for EMEA)
DA - 11359
Worldwide — Version 40 — January 15, 2004
401782-002
FP-MI724-36
376911-022
Page 32
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
Installation & Start-up Services
Hardware Installation (2-5-2 Part Number for Canada)
FP-MIINS-IN
Hardware Installation (6-3 Part Number for US)
401793-002
Hardware Installation (6-3 Part Number for EMEA)
Quote
Pre-installation planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information provided; Install &
configure basic functionality of Win NT Operating System plus up to 1 day start-up activity, configure
print & network access services, and orientation (2-5-2 Part Number for Canada.)
FM-MSTEC-03
Pre-installation planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information provided; Install &
configure basic functionality of Win NT Operating System plus up to 1 day start-up activity, configure
print & network access services, and orientation (6-3 Part Number for U.S.)
240015-002
Pre-installation planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information provided; Install &
configure basic functionality of Novell NetWare Operating System plus up to 1 day start-up activity,
configure print & network access services, and orientation (2-5-2 Part Number for Canada)
FM-NSTEC-03
Pre-installation planning; unpack equipment, install most current Compaq HW options internal to
server at same time of server installation; assemble & test; basic user information provided; Install &
configure basic functionality of Novell NetWare Operating System plus up to 1 day start-up activity,
configure print & network access services, and orientation (6-3 Part Number for U.S.)
240010-002
Server Installation and Set-Up (Installation of the server, installation of the appropriate service tools,
check to ensure device SW and firmware is loaded and installation of the operating system software
(6-3 Part Number for EMEA.)
204564-022
HP Care Pack Priority Services for ProLiant Servers – Priority Level
9x5 4-hour H/W, 9x5 2-hour O/S (NT & NetWare), 3 Years (6-3 Part Number for EMEA)
179836-022
9 x 5 HW, 4-hr response, Next Available HW engineer; 9 x 5 Bronze Software Support 2-hr response
for Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System, Next
Available Specialist (2-5-2 Part Number for Canada)
FM-M01E3-36
9 x 5 HW, 4-hr response, Next Available HW engineer; 9 x 5 Bronze Software Support 2-hr response
for Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System, Next
Available Specialist (6-3 Part Number for U.S.)
239936-002
9 x 5 HW, 4-hr response, Next Available HW engineer; 9 x 5 Bronze Software Support 2-hr response
for Novell NetWare Operating System, Next Available Specialist (2-5-2 Part Number for Canada)
FM-N01E3-36
9 x 5 HW, 4-hr response, Next Available HW engineer; 9 x 5 Bronze Software Support 2-hr response
for Novell NetWare Operating System, Next Available Specialist (6-3 Part Number for U.S.)
239976-002
HP Care Pack Priority Services for ProLiant Servers – Priority 24 Level
24x7 4-hour H/W, 24x7 2-hour O/S (NT & NetWare), 3 years (6-3 Part Number for EMEA)
179841-002
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Bronze Software Support, 2-hr response for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System, Next
Available Specialist (6-3 Part Number for U.S.)
239938-002
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Bronze Software Support, 2-hr response for
Novell NetWare Operating System, Next Available Specialist (6-3 Part Number for U.S.)
239978-002
HP Care Pack Priority Services for ProLiant Servers - Priority Silver
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr response,
Monday – Friday, 8AM – 5PM local time, 2-hr response after hours for Windows NT, Windows 2000,
Professional, Server or Advanced Server Operating System, Technical Account Manager, Technical
Newsletter, SW activity review (2-5-2 Part Number for Canada)
FM-M04E3-36
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr response,
Monday – Friday, 8AM – 5PM local time, 2-hr response after hours for Windows NT, Windows 2000,
Professional, Server or Advanced Server Operating System Operating System, Technical Account
Manager, Technical Newsletter, SW activity review (6-3 Part Number for U.S.)
239940-002
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System (6-3 Part
Number for U.S.)
239942-002
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 33
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System (2-5-2 Part
Number for Canada)
FM-M24E3-36
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr response,
Monday – Friday, 8AM – 5PM local time, 2-hr response after hours for Novell NetWare Operating
System, Technical Account Manager, Technical Newsletter, SW activity review (2-5-2 Part Number for
Canada)
FM-N04E3-36
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Software Support, 1-hr response,
Monday – Friday, 8AM – 5PM local time, 2-hr response after hours for Novell NetWare Operating
System, Technical Account Manager, Technical Newsletter, SW activity review (6-3 Part Number for
U.S.)
239980-002
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support for Novell
NetWare Operating System (2-5-2 Part Number for Canada.)
FM-N24E3-36
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Silver Subsequent System Support for Novell
NetWare Operating System (6-3 Part Number for U.S.)
239982-002
HP Care Pack Priority Services for ProLiant Servers – Priority Gold
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Windows NT, Windows 2000, Professional, Server or
Advanced Server Operating System, Technical Account Manager, Technical Newsletter, SW activity
review, proactive revision management, Upgrade impact planning, 2 System Healthcheck per year
(2-5-2 Part Number for Canada)
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Windows NT, Windows 2000, Professional, Server or
Advanced Server Operating System, Technical Account Manager, Technical Newsletter, SW activity
review, proactive revision management, Upgrade impact planning, 2 System Healthcheck per year (63 Part Number for U.S.)
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System (2-5-2 Part
Number for Canada)
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System (6-3 Part
Number for U.S.)
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Novell NetWare Operating System, Technical Account
Manager, Technical Newsletter, SW activity review, Upgrade impact planning (2-5-2 Part Number for
Canada)
FM-M08E3-36
239944-002
FM-M28E3-36
239946-002
FM-N08E3-36
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Novell NetWare Operating System, Technical Account
Manager, Technical Newsletter, SW activity review, Upgrade impact planning (6-3 Part Number for
U.S.)
239984-002
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for Novell
NetWare Operating System (2-5-2 Part Number for Canada)
FM-N28E3-36
24 x 7 HW, 4-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for Novell
NetWare Operating System (6-3 Part Number for U.S.)
239986-002
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Windows NT, Windows 2000, Professional, Server or
Advanced Server Operating System, Technical Account Manager, Technical Newsletter, SW activity
review, proactive revision management, Upgrade impact planning, 2 System Healthcheck per year
(2-5-2 Part Number for Canada)
FM-M09E3-36
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Windows NT, Windows 2000, Professional, Server or
Advanced Server Operating System, Technical Account Manager, Technical Newsletter, SW activity
review, proactive revision management, Upgrade impact planning, 2 System Healthcheck per year (63 Part Number for U.S.)
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System (2-5-2 Part
Number for Canada)
DA - 11359
Worldwide — Version 40 — January 15, 2004
239948-002
FM-M29E3-36
Page 34
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Options
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for
Windows NT, Windows 2000, Professional, Server or Advanced Server Operating System (6-3 Part
Number for U.S.)
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Novell NetWare Operating System, Technical Account
Manager, Technical Newsletter, SW activity review, Upgrade impact planning (2-5-2 Part Number for
Canada.)
239950-002
FM-N09E3-36
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Software Support, 30 minute response
(critical), 1-hr response (non-critical), for Novell NetWare Operating System, Technical Account
Manager, Technical Newsletter, SW activity review, Upgrade impact planning (6-3 Part Number for
U.S.)
239988-002
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for Novell
NetWare Operating System (2-5-2 Part Number for Canada)
FM-N29E3-36
24 x 7 HW, 2-hr response, Named HW engineer; 24 x 7 Gold Subsequent System Support for Novell
NetWare Operating System (6-3 Part Number for U.S.)
239990-002
NOTE: For more information, customer/resellers can contact http://www.compaq.com/services.
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 35
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Memory
HP ProLiant ML530 Generation 2 (G2)
Advanced ECC Memory Standard
1024 MB (2 x 512-MB) PC1600- ECC SDRAM installed
Advanced ECC Memory Standard Plus Optional Memory
Up to 13,312-MB memory is available with the optional installation of PC1600- ECC SDRAM memory kits
Advanced ECC Memory Standard Replaced with Optional Memory
Up to 16,384-MB of memory is available with the removal of the standard 1024-MB of memory and the optional installation of PC1600-MHz ECC SDRAM
memory kits.
NOTE: This chart does not represent all possible memory configurations.
Standard
Optional
Maximum
1024MB
13,312MB
16,384MB
Bank A
Slot 1
Slot 2
512 MB
512 MB
512 MB
512 MB
2048 MB
2048 MB
Bank B
Slot 3
Slot 4
Empty
Empty
2048 MB
2048 MB
2048 MB
2048 MB
Bank C
Slot 5
Slot 6
Empty
Empty
2048 MB
2048 MB
2048 MB
2048 MB
Bank D
Slot 7
Slot 8
Empty
Empty
2048 MB
2048 MB
2048 MB
2048 MB
Bank C
Slot 5
Slot 6
Empty
Empty
512 MB
512 MB
Bank D
Slot 7
Slot 8
512 MB
512 MB
256 MB
256 MB
Optional Compaq Advanced Memory Protection Configurations
NOTE:
NOTE
-Online Spare Memory: Bank D is the Online Spare Bank.
-Mirrored Memory: Bank C mirrors Bank A, Bank D mirrors Bank B.
NOTE: This chart does not represent all possible memory configurations.
Online
Mirrored
2560MB
3072MB
Bank
Slot 1
512 MB
512 MB
A
Slot 2
512 MB
512 MB
Bank
Slot 3
256 MB
256 MB
B
Slot 4
256 MB
256 MB
Following are memory options available from HP:
512-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 256 MB)
187418-B21
1024-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 512 MB)
187419-B21
2048-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 1024 MB)
187420-B21
4096-MB PC1600-MHz Registered ECC SDRAM Memory Option Kit (2 x 2048 MB)
187421-B21
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 36
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Storage
2X 0 - 5
Two 6 x1 inch Wide Ultra3 SCSI Hard Drive Cages
A
1.44-MB Diskette Drive
B
40x IDE CD-ROM
C, D
2X 0 - 5
Two available half height bays for tape backup, DVD, SCSI storage, or optional
ML5xx Internal Two Bay Hot Plug Wide SCSI Drive Cage (with fan)
Two 6 x1 inch Wide Ultra3 SCSI Hard Drive Cages
A
1.44-MB Diskette Drive
B
40x IDE CD-ROM
C, D
Two available half height bays for tape backup, DVD, SCSI storage, or optional
ML5xx Internal Two Bay Hot Plug Wide SCSI Drive Cage (with fan)
Drive Support
Quantity
Supported
Position
Supported
Controller
1.44-MB Diskette Drive
Up to 1
A
Integrated
IDE CD-ROM Drive
Up to 1
B
Integrated IDE
DVD-ROM Drive Option Kit
Up to 1
B, C, D
Integrated IDE
ML5xx Internal Two Bay Hot
Plug Wide SCSI Drive Cage
(with fan)
Up to 1
C, D
Integrated SCSI
Removable Media
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 37
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Storage
Hard Drives
Ultra320 Hot Pluggable Drives
Quantity
Supported
1-inch Drives
146.8-GB 10,000 rpm
72.8-GB 10,000 rpm
36.4-GB 10,000 rpm
72.8-GB 15,000 rpm
36.4-GB 15,000 rpm
18.2-GB 15,000 rpm
Position
Supported
Up to 12
2X 0-5
Up to 14 (With
optional Drive Cage 2X 0-5, C, D
and ML5xx Internal
Two Bay Hot Plug
Wide SCSI Drive
Cage)
Controller
Integrated Dual Channel Wide Ultra3 SCSI Adapter
Smart Array 532 Controller
Smart Array 5302/128 Controller
Smart Array 5304/256 Controller
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 641 Controller
Smart Array 642 Controller
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
NOTE: All U320 Universal Hard Drives are backward compatible to U2 or U3 speeds. U320 drives require an optional U320 Smart Array Controller or
U320 SCSI HBA to support U320 transfer rates
External Storage
Quantity
Supported
Modular Smart Array 30 Family Up to 28
Modular Smart Array 1000
Position
Supported
External
Host Controller or Adapter
Smart Array 5302/128 Controller
Smart Array 5304/256 Controller
Smart Array 6402/128 Controller
Smart Array 6404/256 Controller
Smart Array 642 Controller
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
Please see the
External
Modular Smart Array
1000 QuickSpecs
below to determine
configuration
requirements
Please see the Modular Smart Array 1000 QuickSpecs (URL below) for the latest
list of supported HBAs
Modular Smart Array 1000: http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.HTML (Worldwide)
http://h18000.www1.hp.com/products/quickspecs/11033_na/11033_na.HTML (North America)
Maximum Storage Capacity – (Ultra3 Drive Cage, ML5xx Two Bay Hot Plug SCSI Drive Cage, 4channel controller in all 7 slots & MSA30 enclosures)
Internal
2.055 TB (14 x 146.8-GB Ultra320 1" Drives)
External
49.324 TB (24 StorageWorks Enclosures each with 14 x 146.8-GB Ultra320 1" Drives)
Total
51.380 TB
Tape Drives
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Drives listed below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/North_America/10233.html (North America)
http://h18000.www1.hp.com/products/quickspecs/Division/10233.html (Worldwide)
NOTE: For an up-to-date listing of the latest O/S Support details for each of the Tape Storage Systems listed below, please see the following:
http://h18000.www1.hp.com/products/quickspecs/North_America/10809.html (North America)
http://h18000.www1.hp.com/products/quickspecs/Division/10809.html (Worldwide)
NOTE: For an up-to-date listing of the latest controllers supported for each of the Tape Drives listed below, please see the following:
http://www.hp.com/products1/storage/compatibility/tapebackup/proliant/index.html.
Quantity
Supported
Position
Supported
DA - 11359
Controller
Worldwide — Version 40 — January 15, 2004
Page 38
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Storage
Internal 20/40-GB DAT DDS-4 Up to 2
Internal 12/24-GB DAT
Internal DAT 72 Tape Drive
C, D
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
20/40-GB DDS-4 8 Cassette
Autoloader
Up to 2
C, D
Integrated Dual Channel Wide Ultra3 Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
Ultrium 215, External
Ultrium 230, External
Ultrium 460, External
Up to 2
External
Integrated Dual Channel Wide Ultra3 Adapter
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
Ultrium 230, Internal
Ultrium 460, Internal
Up to 1
C+D
(two bays)
Integrated Dual Channel Wide Ultra3 Adapter
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133Mhz Dual Channel Ultra320 SCSI Adapter
Internal 40/80-GB DLT
1
C, D
(two bays)
Integrated Dual Channel Wide Ultra3 Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
Internal DLT VS 40/80
Up to 2
C, D
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
External DAT 72 Tape Drive
Up to 2
External
Integrated Dual Channel Wide Ultra3 Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
HP StorageWorks AIT 35 GB
Autoloader
Up to 1 (for a single External
HBA)
Up to 2 (for a dual
HBA)
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
Internal SDLT 110/220-GB
Tape Drive
Internal SDLT 160/320-GB
Tape Drive
1
C+D
(two bays)
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
SDLT 110/220-GB, External
LTO Ultrium 230,
External
Up to 3
External
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
SDLT 160/320-GB, External
LTO Ultrium 460,
External
Up to 3
External
64-bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
External DLT VS 40/80
External DLT 40/80-GB
Up to 3
External
Integrated Dual Channel Wide Ultra3 Adapter
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
SSL2020 AIT Mini-Library
Up to 5
External
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
SSL1016 tape autoloader
Up to 2 drives
External
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
MSL5026DLX (40/80GB DLTbased)
MSL5026SL (SDLT-based)
Library
MSL5052SL (SDLT-based)
Library
MSL5030 (LTO-based) Library
MSL5060 (LTO-based) Library
MSL6030 (LTO-based) Library
MSL6060 (LTO-based) Library
2 drives per SCSI
channel
External
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
DLT1 1280 SuperLoader
Up to 2
External
64-Bit/66-MHz Dual Channel Wide Ultra3 SCSI Adapter, Alternate OS
64-Bit/133-MHz Dual Channel Ultra320 SCSI Adapter
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 39
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Power Specifications
Part Number
230822-001
Spare Kit
231782-001
Operational Input Voltage Range (V
rms)
90 to 264
Frequency Range (Nominal) (Hz)
47 to 63 (50/60)
Nominal Input Voltage (Vrms)
Max Rated Output Wattage Rating
Nominal Input Current (A rms)
Max Rated Input Wattage Rating (Watts)
Max. Rated VA (Volt-Amp)
Efficiency (%)
Power Factor
Leakage Current (mA)
Maximum Inrush Current (A peak)
Maximum Inrush Current duration (mS)
100
600
9.4
923
942
65
115
600
8.1
909
928
66
208
600
4.4
914
914
67
0.31
15
0.36
17
0.65
30
220
600
4.1
882
900
68
230
600
3.9
870
887
69
240
600
3.6
857
875
70
0.69
32
0.72
34
0.75
35
0.98
20
System Specifications
Processor
Memory
HDD
PCI
PS
2
16
12
7
2
Fully Loaded System Input Wattage (W)
902
888
875
862
850
Fully Loaded System Input Current (A rms)
9.2
7.9
4.3
4.0
3.8
3.6
3076
3029
2984
2940
2898
2856
920
906
893
880
867
855
ML530 G2 Fully Configured
Fully Loaded System Thermal (BTU-Hr)
Fully Loaded System VA (Volt-Amp)
Power cord requirements
838
Nema 5-15P to IEC320-C13
Option no./Spare no.: See Power Cord chart
IEC320-C13 to IEC320-C14
Option no. /Spare no.: 142259-001/142258-B21
NOTES:
ActiveAnswers Power Calculation
Power calculator is LIVE on ActiveAnswers website. This is an external link.
Follow this link: http://h30099.www3.hp.com/configurator/powercalcs.asp.
To drill down to calculators:
- Click on: "ProLiant Servers"
Click on the Server of interest. Example: ML530 G2
Click on: "Power Calculator" link (You may need to scroll down to see it.)
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 40
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
Power Specifications
Power Cords (13 Cord Sets)
Power Cord Part Number
Country
APD
139867-006
APD
100613-003
APD
100614-003
Australia
100611-007
Europe
100614-003
France
100614-003
Germany
100614-003
Japan
139867-006
PRC
139867-006
PRC
100613-003
PRC
100661-007
UK
100613-003
US
163719-002
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 41
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
TechSpecs
System Unit – Tower
Dimensions (HxWxD)
(with feet/bezel)
20.0 x 12.8 x 27.8 in (50.8 x 32.5 x 70.6 cm)
Weight
100 lb (45.36 kg)
No hard drives installed, one power supply
Input Requirements
(per power supply)
Range Input Voltage
100 to 127 VAC/200 to 240 VAC
Rated Input Frequency
47 to 63 Hz
Input Power
690W @ 110 VAC
Rated Input Current
7.6A
BTU Rating
2400 BTU/hr
SCSI Connectors
Two internal HD68 connectors (supporting Wide Ultra3)
One external VHDCI connector (supporting Wide Ultra3)
One SCSI knockout
Power Supply Output
Power (per power supply)
Rated Steady-State Power
Acoustic Noise
Idle
(Fixed Disk Drives Spinning)
600W
Maximum Peak Power
L WAd (BELS)
7.0
Operating
(Random Seeks to Fixed Disks)
L WAd (BELS)
System Unit Rack
7.1
Dimensions (HxWxD)
12.8 x 17.5 x 25.6 in (32.5 x 44.4 x 65.0 cm)
Weight (approximate)
100 lb (45.36 kg)
No hard drives installed, one power supply
Input Requirements
(per power supply)
Range Input Voltage
100 to 127 VAC/200 to 240 VAC
Rated Input Frequency
47 to 63 Hz
Input Power
690W @ 110 VAC
Rated Input Current
7.6A
BTU Rating
2400 BTU/hr
SCSI Connectors
Two internal HD68 connectors (supporting Wide Ultra3)
One external VHDCI connector (supporting Wide Ultra3)
One SCSI knockout
Power Supply Output
Power (per power supply)
Rated Steady-State Power
Acoustic Noise
Idle
(Fixed Disk Drives Spinning)
600W
Maximum Peak Power
L WAd (BELS)
6.7
Operating
(Random Seeks to Fixed Disks)
L WAd (BELS)
DA - 11359
6.8
Worldwide — Version 40 — January 15, 2004
Page 42
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
TechSpecs
1.44-MB Diskette Drive
40X Max IDE
CD-ROM Drive
Diskette Size
3.5 in (8.89 cm)
LED Indicators
(front panel)
Green
Read/Write Capacity per
Diskette (high/low density)
1.44 MB/720 KB
Drive Supported
One
Drive Height
One-third
Drive Rotation
300 rpm
Transfer Rate
(high/low)
500 K/250 K bits/s
Bytes/Sector
512
Sectors/Track (high/low)
18/9
Tracks/Side (high/low)
80/80
Access Times
Track-to-Track (high/low)
3/6 ms
Average (high/low)
169/94 ms
Settling Time
15 ms
Latency Average
100 ms
Cylinders (high/low)
80/80
Read/Write Heads
Two
Disk
Applicable Disk
CD-ROM, CD-XA, CD-DA (Mode 1, Mode 2, Form 1
and 2)
Photo CD (Single and Multi-session)
Mixed Mode (Audio and Data combined)
CD-R
Capacity
540 MB (Mode 1, 12 cm)
650 MB (Mode 2, 12 cm)
Block Size
Mode 1
2,048 bytes
Mode 2
2,340 bytes, 2,336 bytes
CD-DA
2,352 bytes
CD-XA
2,328 bytes
Interface
IDE (ATAPI)
Access Times (typical)
Random
100 ms
Full-Stroke
150 ms
Audio Output Level
Line-Out
0.7 VRMS at 47 kOhms
Data Transfer Rate
Sustained
150 KB/s (1X audio)
Burst
16.67 Mbytes/sec
Cache Buffer
128 KB
Start-up Time (typical)
< 7 seconds
Stop Time
< 4 seconds
Laser Parameters
Type
Semiconductor Laser GaA1As
Wave Length
780 ± 25 nm
Temperature
41° to 113° F (5° to 45° C)
Humidity
10% to 80%
(HxWxD, maximum)
1.7 x 5.85 x 8.11 in (4.29 x 14.86 x 20.60 cm)
Weight
2.09 lb (0.95 kg)
Operating Conditions
Dimensions
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 43
QuickSpecs
HP ProLiant ML530 Generation 2 (G2)
TechSpecs
Integrated Dual Channel Drives Supported
Wide Ultra3 SCSI Adapter Data Transfer Method
Compaq NC3163 Fast
Ethernet NIC Embedded
10/100 WOL
(Wake On LAN)
Video Controller
Up to 15 SCSI devices per channel
64-bit PCI bus-master
SCSI Channel Transfer
Rate
160 MB/s per channel
Maximum Transfer Rate
per PCI Bus (peak)
267 MB/s
SCSI Termination
Active Termination
SCSI Connectors
1 external, 2 internal (68-pin)
Network Interface
10Base-T/100Base-TX
Compatibility
IEEE 802.3/802.3u compliant
Data Transfer Method
32-bit bus-master PCI
Network Transfer Rate
10Base-T (Half-Duplex)
10 Mb/s
10Base-T (Full-Duplex)
20 Mb/s
100Base-TX (Half-Duplex)
100 Mb/s
100Base-TX (Full-Duplex)
200 Mb/s
Connector
10Base-T
Categories 3, 4 or 5 UTP; up to 328 ft (100 m)
Cable Support
100Base-TX
Category 5 UTP; up to 328 ft (100 m)
Controller Chip
ATI RAGE XL
Video DRAM
8 MB Video SDRAM
Data Transfer Method
32-bit PCI
Support Resolution
Supported Color Depths:
640 x 480
16.7M, 64K, 256, 16
800 x 600
16.7M, 64K, 256, 16
1024 x 768
16.7M, 64K, 256, 16
1152 x 864
16.7M, 64K, 256, 16
1280 x 1024
16.7M, 64K, 256, 16
1600 x 1200
64K, 256, 16
Connector
VGA
© Copyright 2004 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice.
Microsoft and Windows NT are US registered trademarks of Microsoft Corporation. Intel is a US registered trademark of Intel Corporation.
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein
should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.
DA - 11359
Worldwide — Version 40 — January 15, 2004
Page 44
Download PDF