G2 Optima Plus 8137 Specification Sheet

Model
8137
Battery Powered Flushometers
Buy
Ac t •
t
n
n
om
C
plia
•
Ac t •
u
om
£ Model 8137-1.6 Low Consumption (1.6 gpf/6.0 Lpf)
£ Model 8137-2.4 (2.4 gpf/9.0 Lpf)
£ Model 8137 Water Saver (3.5 gpf/13.2 Lpf)
plia
n
Specifications
Quiet, Exposed, Diaphragm Type, Chrome Plated Closet Flushometer for either left or right
hand supply with the following features:
• PERMEX® Synthetic Rubber Diaphragm with Dual Filtered Fixed Bypass
• Flex Tube Diaphragm designed for improved life and reduced maintenance
• ADA Compliant OPTIMA Plus® Battery Powered Infrared Sensor for automatic “No
Hands” operation
• Infrared Sensor with Multiple-focused, Lobular Sensing Fields for high and low target
detection
• Latching Solenoid Operator
• Engineered Metal Cover with replaceable Lens Window
• User friendly three (3) second Flush Delay
• Courtesy Flush® Override Button
• Four (4) Size AA alkaline Batteries included: Duracell® with DURALOCK Power
Preserve Technology™-guaranteed for up to 10 years in storage
• “Low Battery” Flashing LED
• Infrared Sensor Range Adjustment Screw
• Initial Set-up Range Indicator Light (first 10 minutes)
• 1” I.P.S. Screwdriver Bak-Chek® Angle Stop
• Free Spinning, Vandal Resistant Stop Cap
• Adjustable Tailpiece
• High Back Pressure Vacuum Breaker Flush Connection with One-piece Bottom Hex
Coupling Nut
• Sweat Solder Adapter with Cover Tube and Cast Set Screw Wall Flange
• High Copper, Low Zinc Brass Castings for Dezincification Resistance
• Fixed Metering Bypass and No External Volume Adjustment to Ensure Water
Conservation
• Flush Accuracy Controlled by CID Technology
• Diaphragm, Stop Seat and Vacuum Breaker to be molded from PERMEX® Rubber
Compound for Chloramine resistance
• 100% of the energy used in manufacturing is offset with Renewable Energy Sources
– Wind Energy
Valve Body, Tailpiece and Control Stop shall be in conformance with ASTM Alloy
Classification for Semi-Red Brass. Valve shall be in compliance with the applicable sections
of ASSE 1037, ANSI/ASME A112.19.2. Installation conforms to ADA requirements.
u
n
Flush Cycle
C
u
•
u
e r i ca
Am
e r i ca
Am
Description
Exposed, Battery Powered, Sensor Operated G2® Model Water Closet Flushometer for back
inlet squat toilets.
Buy
u
t
OPTIMA SYSTEMS
Made with
Renewable Energy
u
u
u
ADA Compliant
Automatic
Sloan G2 Optima Plus® Flushometers activate via multi-lobular
sensor detection to provide the ultimate in sanitary protection and
automatic operation. A battery powered infrared sensor sets the
flushing mechanism after the user is detected and completes the
flush when the user steps away.
Functional & Hygienic
Made with
Touchless, sensor operation eliminates the need for Renewable
user contact
to
Energy
help control the spread of infectious diseases. The G2 Optima Plus
Flushometer is provided with an Override Button to allow a
"courtesy flush" for individual user comfort.
u
Economical
Sloan installed batteries speed installation and provide years of
metered flushing to control the use of water and energy. Batteries
can be changed without turning off the water.
u
Warranty
3 year (limited)
Variations
£U
£ XYV
£ YJ
£ YK
1¼” Flush Connection
Less Vacuum Breaker
Split Ring Pipe Support
Solid Ring Pipe Support
C
Special Finishes
£ PB
Polished Brass (PVD Finish)
£ BN
Brushed Nickel (PVD Finish)
£ SF
Satin Chrome
NOTE: Bak-Chek™ Angle Stop available with 1” Whitworth Thread (please specify).
This space for Architect/Engineer approval
Job Name
Date
Model Specified
Quantity
Variations Specified
Customer/Wholesaler
Contractor
Architect
G2 Optima Plus 8137 12-13
The information contained in this document is subject to change without notice.
Model
8137
u
Description
Exposed, Battery Powered, Sensor Operated G2® Model Water Closet Flushometer for back inlet
squat toilets.
u
Flush Cycle
£ Model 8137-1.6 Low Consumption (1.6 gpf/6.0 Lpf)
£ Model 8137-2.4 (2.4 gpf/9.0 Lpf)
£ Model 8137 Water Saver (3.5 gpf/13.2 Lpf)
ELECTRICAL SPECIFICATIONS
Control Circuit
Solid State
6 VDC Input
8 Second Arming Delay
3 Second Flush Delay
u
u
OPTIMA Sensor Type
Active Infrared
u
u
OPTIMA Sensor Range
Nominal 22” - 42” (559 mm -1067 mm),
Adjustable ± 8” (203 mm)
u
u
u
u
Battery Type
(4) Size AA Alkaline: Duracell® with
DURALOCK Power Preserve Technology™
Battery Life
3 Years @ 4,000 Flushes/Month
Indicator Lights
Range Adjustment/Low Battery
Operating Pressure
15 - 100 psi (104 - 689 kPa)
Sentinel Flush
Once Every 24 Hours After the Last Flush
OPERATION
1. A continuous, invisible light
beam is emitted from the
OPTIMA Plus Sensor.
2. As the user enters the beam’s
effective range (22” to 42”)
the beam is reflected into the
OPTIMA
Plus Scanner
Window and transformed into
a low voltage electrical circuit.
Once activated, the Output
Circuit continues in a “hold”
mode for as long as the user
remains within the effective
range of the Sensor.
3. When the user steps away
from the OPTIMA Plus Sensor,
the circuit waits 3 seconds (to
prevent false flushing) then
initiates an electrical signal
that operates the Solenoid.
This initiates the flushing
cycle to flush the fixture. The
Circuit then automatically
resets and is ready for the
next user.
VALVE ROUGH-IN
Model 8137
The Model 8137 no longer requires the
use of a Beam Deflector to properly target
the user.
SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloanvalve.com
Copyright © 2013 Sloan Valve Company
G2 Optima Plus 8137 12-13