The RuggedSwitch

®

RSG2100NC is an industrially hardened, fully managed, modular, Ethernet switch specifically designed to

ZPL embedded Rugged Operating System (ROS

®

ZPL

) provides improved system reliability and advanced cyber security and networking features making it ideally suited for creating secure Ethernet networks for mission-critical, real-time, control applications.

The RSG2100NC’s modular flexibility offers 10BaseFL

/100BaseFX /1000BaseX fiber and 10/100/1000BaseTX copper port combinations. Optional front or rear mount connectors make the RSG2100NC highly versatile for any application and can support multiple fiber connectors (ST, MTRJ, LC, SC) without loss of port density. The RSG2100NC is packaged in a rugged galvanized steel enclosure with industrial grade DIN, panel, or

19” rack-mount mounting options.

RuggedRated™ for Reliability in Harsh Environments

„ Immunity to EMI and heavy electrical surges z z z z z eRSTP

Zero-Packet-Loss™ Technology

„

Class 1 with copper ports or Class 2 with all fiber ports

Exceeds IEC 61850-3 (electric utility substations)

Exceeds IEC 61800-3 (variable speed drive systems)

Exceeds IEC 61000-6-2 (generic industrial)

„

TM

„ -40°C to +85°C operating temperature (no fans)

„

„

Rugged Operating

„ 18 AWG galvanized steel enclosure

System™

„ Hazardous Location Certification: Class 1 Division 2

Rugged Operating System (ROS

®

) Features

negotiation, and crossover detection

„

„ RSTP (802.1w) and Enhanced Rapid Spanning

Features and Benefits

Ethernet Ports

„ Up to 3-Gigabit Ethernet ports - copper and/or fiber

„

„ „ 2 port modules for tremendous flexibility

„

„ Supports many types of fiber (Multimode, singlemode, bi-directional single strand)

„ Long haul optics allow Gigabit distances up to 70km

„ Multiple connector types (ST, MTRJ, LC, SC)

Cyber Security Features

„ Multi-level user passwords

„

„ Enable/disable ports, MAC based port security

„

„ VLAN (802.1Q) to segregate and secure network traffic

„ RADIUS centralized password management

„ SNMPv3 authentication and 56-bit encryption

Tree (eRSTP™) network fault recovery (<5ms)

„

„ „ VLAN (802.1Q) with double tagging and GVRP support

„

„ „ IGMP Snooping for multicast filtering

„

„ Port configuration, status, statistics, mirroring, security

„ SNTP time synchronization (client and server)

„ Industrial automation features (eg. Modbus)

Management Tools

„ Web-based, Telnet, CLI management interfaces

„

„

„ Rich set of diagnostics with logging and alarms

Universal Power Supply Options

„ Fully integrated, dual-redundant (optional) power supplies

„

„ Popular low voltage ranges: 24VDC(10-36VDC),

48VDC (36-72VDC)

Screw or pluggable terminal blocks available

Terminal blocks for reliable maintenance free connections

CSA/UL 60950 safety approved to +85°C

RUGGEDCOM

ISO 9001

REGISTERED www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

1

Modularity:

X X

X

Up to 16 Fast Ethernet ports & 3

Gigabit ports

X X

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

RuggedSwitch

®

RSG2100NC

Modularity (8x2)

Mounting Options

X

X

Panel/Din Rail

X

X X

Fast Ethernet Ports Types:

X

X up to 16 Fast Ethernet Ports

X

X copper desired

X

X

X

10FL Multimode

X

X X

Gigabit Port Types:

X

X up to 3 Gigabit Ethernet Ports

X

X

X

1000SX Multimode

X

X

X

Pluggable Optics (SFP and GBIC)

X

Modular HMI:

X X

Integrated Power Supply

X X

X

X or 85-264VAC

Popular low voltage DC ranges: 24VDC

X

(10-36VDC), 48VDC (36-59VDC)

X

X

(Optional)

X available

Operating Temperature

X

-40 o

C to +85 o

C

X X

Critical Alarm Relay

X X

Max Voltage 250VAC,125VDC

Max Current 2A@250VAC,

0.15A@125VDC, 2A@30VDC www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

2

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

Cyber Security

Cyber security is an urgent issue in many industries where advanced automation and communications networks play a crucial role in mission critical applications and where high reliability is of paramount importance. Key ROS

®

features that address security issues at the local area network level include:

„ Passwords - Multi-level user passwords secures switch against unauthorized configuration

Enable/Disable Ports - Capability to disable ports so that traffic can not pass

802.1Q VLAN - Provides the ability to logically segregate traffic between predefined ports on switches

MAC Based Port Security - The ability to secure ports on a switch so only specific Devices / MAC addresses can communicate via that port

„ lock down ports on a switch so that only authorized clients can communicate via this port

„ providing centralized password management

„ SNMPv3 - encrypted authentication access security and data encryption (CBC-DES with 56-bit encryption key)

„ Secure Socket Layer - Web-based management using SSL with data encryption (56-bit encryption key)

„ RSA – 1024 bit key for key management and key exchange

„

Client provides cleartext authentication and authorization

„ Point to Point (PPP) - using CHAP (MD5 Hash) authentication service

The ROS

®

cyber security features are included to help address the various industry specific security standards such as NERC CIP, ISA S99, AGA 12, IEC 62443, ISO 17799:2005 and PCSRF SPP-ICS.

Enhanced Rapid Spanning Tree Protocol (eRSTP™)

RuggedCom eRSTP™ allows the creation of fault-tolerant ring and mesh Ethernet networks that incorporate redundant links that are ‘pruned’ to prevent loops. eRSTP™ yields worstcase fault recovery

1

of 5ms times the ‘bridge diameter’ and allows rings of up to 160 switches. For example, a ring of ten switches will have fault recovery times under 50ms. eRSTP™ implements both STP and RSTP to ensure interoperability with commercial switches unlike other proprietary ‘ring’ solutions.

Quality of Service (IEEE 802.1p)

Some networking applications such as real-time control or VoIP

(voice over IP) require predictable arrival times for Ethernet frames.

Switches can introduce latency in times of heavy network traffic due to the internal queues that buffer frames and then transmit on a first come first serve basis. ROS

®

supports ‘Class of Service’ in accordance with IEEE 802.1p that allows time critical traffic to jump ahead to the front of the queue thus minimizing latency and

ROS

®

Features

reducing jitter to allow such demanding applications to operate correctly. ROS

®

allows priority classification by port, tags, MAC address, and IP type of service (ToS).

A configurable “weighted fair queuing” algorithm controls how frames are emptied from the queues.

VLAN (IEEE 802.1Q)

Virtual local area networks (VLAN) allow the segregation of a physical network into separate logical networks with independent broadcast domains. A measure of security is provided since hosts can only access other hosts on the same VLAN and traffic storms are isolated. ROS

®

supports 802.1Q tagged Ethernet frames and VLAN trunks. Port based classification allows legacy devices to be assigned to the correct VLAN. GVRP support is also provided to simplify the configuration of the switches on the

VLAN.

Link Aggregation (802.3ad)

The link aggregation feature provides the ability to aggregate several Ethernet ports into one logical link (port trunk) with higher bandwidth. This provides an inexpensive way to set up a high speed backbone to improve network bandwidth. This feature is also known as “port trunking”, “port bundling”, “port teaming”, and “Ethernet trunk”.

IGMP Snooping

ROS

®

uses IGMP snooping (Internet Group Management

Protocol v1&v2) to intelligently forward or filter multicast traffic streams (e.g. MPEG video) to or from hosts on the network.

This reduces the load on network trunks and prevents packets from being received on hosts that are not involved. ROS a very powerful implementation of IGMP snooping that:

®

has

Can be enabled on a per VLAN basis.

„ subscribers exist.

Supports “router-less” operation by supporting an “active” mode.

„ topology change.

SNMP (Simple Network Management Protocol)

SNMP provides a standardized method for network management stations the ability to interrogate devices from different vendors. SNMP versions supported by ROS v2c, and v3.

SNMPv3 in particular provides security features such as authentication, privacy with data encryption (CBC-DES with 56-bit encryption key) and access control not present in earlier SNMP versions.

ROS

®

®

are v1,

also supports numerous standard

MIBs (Management Information Base) allowing for easy integration with any network management system (NMS).

1 eRSTP™ fault recovery times may be approximated as follows:

For 100 Mbps, fault recovery performance is <5ms/hop

For 1,000 Mbps, fault recovery performance is <5ms/hop + 20ms www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

3

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

SNMP (Simple Network Management Protocol) (cont’d)

A feature of SNMP supported by ROS

®

is the ability to generate

“traps” upon system events. RuggedNMS™, the RuggedCom management solution, can record traps from multiple devices providing a powerful network troubleshooting tool. It also provides a graphical visualization of the network and is fully integrated with all RuggedCom products.

ROS

®

Features

Port Mirroring

ROS

®

can be configured to duplicate all traffic on one port to a designated mirror port. When combined with a network analyzer, this can be a powerful troubleshooting tool.

SNTP (Simple Network Time Protocol)

SNTP automatically synchronizes the internal clock of all ROS

® devices on the network. This allows for correlation of time stamped events for troubleshooting.

Port Configuration and Status

ROS

®

allows individual ports to be ‘hard’ configured for speed, duplex, auto-negotiation, flow control and more. This allows proper connection with devices that do not negotiate or have unusual settings. Detailed status of ports with alarm and SNMP trap on link problems aid greatly in system troubleshooting.

SCADA and Industrial Automation

ROS

®

contains features that optimize network performance and simplify switch management based on the unique requirements found in SCADA and industrial automation applications. Features such as Modbus TCP management for retrieval of switch data using the ubiquitous Modbus protocol and DHCP Option 82, a Rockwell Automation ODVA requirement for IP address assignment based on the location of the end device, provide capabilities not found in typical “commercial” or “office grade”

Ethernet switches.

Port Based Network Access Control (802.1x)

ROS

®

supports the IEEE 802.1x standard that defines a mechanism for port-based network access control which provides a means of authenticating and authorizing devices attached to LAN ports.

Port Statistics and RMON (Remote Monitoring)

ROS

®

provides continuously updating statistics per port that provide both ingress and egress packet and byte counters as well as detailed error figures. Also provided is full support for the RMON statistics, history, alarms, and event groups.

RMON allows for very sophisticated data collection, analysis and detection of traffic patterns.

Event Logging and Alarms

ROS

®

records all significant events to a non-volatile system log allowing forensic troubleshooting. Events include link failure and recovery, unauthorized access, broadcast storm detection, and self-test diagnostics among others.

Alarms provide a snapshot of recent events that have yet to be acknowledged by the network administrator. An external hardware relay is de-energized during the presence of critical alarms allowing an external controller to react if desired.

Port Rate Limiting

ROS

®

supports configurable rate limiting per port to limit unicast and multicast traffic. This can be essential to managing precious network bandwidth for service providers. It also provides edge security for denial of service (DoS) attacks.

HTML Web Browser and Telnet User Interfaces

ROS

®

provides a simple, intuitive user interface for configuration and monitoring via a standard graphical web browser or via

Telnet. All system parameters include detailed on-line help to make setup a breeze. ROS

®

, presents a common look and feel and standardized configuration process allowing easy migration to other RuggedCom managed products.

Broadcast Storm Filtering

Broadcast storms wreak havoc on a network and can cause attached devices to malfunction. This could be disastrous on a network with mission critical equipment. ROS

®

limits this by filtering broadcast frames with a user-defined threshold.

Loss of Link Management

Some intelligent electronic devices (IEDs) have dual fiber optic ports with automatic failover to a backup port should the primary fail. ROS

®

ensures this mechanism works reliably under all failure modes by appropriately disabling link signals when required. ROS

®

also flushes learned MAC addresses to ensure the failover occurs quickly.

Configuration via ASCII Text File

All configuration parameters are stored in an ASCII formatted text file that can easily be transferred via TFTP or Xmodem.

The configuration file can be saved for backup purposes and easily manipulated by a text editor. The same text file can be downloaded to the switch at a later date in order to re-configure or restore a previous configuration.

Command Line Interface (CLI)

A command line interface can be used in conjunction with remote shell to automate data retrieval, configuration updates, and firmware upgrades. A powerful SQL-like capability allows expert users the ability to selectively retrieve or manipulate any parameters the device has to offer.

www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

4

TEST

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-8

IEC 61000-4-29

IEC 61000-4-11

IEC 61000-4-12

IEC 61000-4-16

IEC 61000-4-17

IEC 60255-5

IEC 60255-5

Test

IEEE C37.90.3

IEEE C37.90.2

IEEE C37.90.1

IEEE C37.90.1

IEEE C37.90

IEEE C37.90

Test

IEC 60068-2-1

IEC 60068-2-2

IEC 60068-2-30

IEC 60255-21-1

IEC 60255-21-2

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

EMI and Environmental Type Tests

IEC 61850-3 EMI TYPE TESTS

ESD

Radiated RFI

Description

Burst (Fast Transient)

+/- 8kV

+/- 15kV

20 V/m

+/- 4kV @ 2.5kHz

+/- 4kV

+/- 4kV

Test Levels

Enclosure Contact

Enclosure Air

Enclosure ports

Signal ports

D.C. Power ports

A.C. Power ports

Surge

Induced (Conducted) RFI

8 Magnetic Field

Voltage Dips & Interrupts

Damped Oscillatory

Mains Frequency Voltage

Ripple on D.C. Power Supply

Dielectric Strength

H.V. Impulse

Earth ground ports

Signal ports

D.C. Power ports

A.C. Power ports

Signal ports

D.C Power ports

A.C. Power ports

Earth ground ports

Enclosure ports

D.C. Power ports

A.C. Power ports

Signal ports

D.C. Power ports

A.C. Power ports

Signal ports

D.C. Power ports

D.C. Power ports

Signal ports

D.C. Power ports

A.C. Power ports

Signal ports

D.C. Power ports

A.C. Power ports

+/- 4kV

+/- 4kV line-to-earth, +/- 2kV line-to-line

+/- 2kV line-to-earth, +/- 1kV line-to-line

+/- 4kV line-to-earth, +/- 2kV line-to-line

10V

10V

10V

10V

40 A/m continuous, 1000 A/m for 1 s

1000 A/m for 1 s

30% for 0.1s, 60% for 0.1s, 100% for 0.05s

30% for 1 period, 60% for 50 periods

100% for 5 periods, 100% for 50 periods

2.5kV common, 1kV diff. mode@1MHz

2.5kV common, 1kV diff. mode@1MHz

2.5kV common, 1kV diff. mode@1MHz

30V Continuous, 300V for 1s

30V Continuous, 300V for 1s

10%

2kVac (Fail-Safe Relay output)

1.5kV DC

2kVac

5kV (Fail-Safe Relay output)

5kV

5kV

ESD

Radiated RFI

Fast Transient

Oscillatory

H.V. Impulse

Dielectric Strength

IEEE 1613 (C37.90.x) EMI IMMUNITY TYPE TESTS

2

Description

Enclosure Contact

Enclosure Air

Enclosure ports

Signal ports

D.C. Power ports

A.C. Power ports

Earth ground ports3

Signal ports

D.C. Power ports

A.C. Power ports

Signal ports

D.C. Power ports

A.C. Power ports

Signal ports

D.C. Power ports

A.C. Power ports

Test Levels

+/-2kV, +/-4kV, +/- 8kV

+/-4kV, +/-8kV, +/-15kV

35 V/m

+/- 4kV @ 2.5kHz

+/- 4kV

+/- 4kV

+/- 4kV

2.5kV common mode @1MHz

2.5kV common, 1kV diff. mode@1MHz

2.5kV common, 1kV diff. mode@1MHz

5kV (Fail-Safe Relay output)

5kV

5kV

2kVac

1.5kV DC

2kVac

Cold Temperature

Dry Heat

Environmental Type Tests

Description

Test Ad

Test Bd

Test Levels

-40°C, 16 Hours

+85°C, 16 Hours

Test Db Humidity (Damp Heat, Cyclic)

Vibration

Shock

95% (non-condensing), 55°C , 6 cycles

2g @ (10 - 150) Hz

30g @ 11mS

Severity Levels

4

4

Note 1

Note 1

4

4

3

3

3

Note 1

5

N/A

4

4

3

4

3

N/A

N/A

4

3

N/A

N/A

N/A

N/A

3

4

3

3

N/A

N/A www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

5

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

Power Supply

Power Consumption: 28W Max

24VDC: 10-36 VDC, 1.2A

48VDC: 36-72 VDC, 0.6A

HI Voltage AC/DC: 88-300VDC or 85-264VAC

Critical Alarm Relay

Form-C contact ratings:

„ Max Voltage 250VAC,125VDC

„

„ 2A@30VDC

Physical

Height: 4.42cm / 1.74”

Width: 46.48cm / 18.3”

Depth: 31.5cm / 12.4”

Weight: 5.2kg / 11.5 lbs

Ingress Protection: IP40 (1mm objects)

Enclosure: 18 AWG galvanized steel enclosure

Mounting: DIN rail or panel mounted

Switch Properties

Switching method: Store & Forward

Switching latency: 7 us

Switching bandwidth: 9.2 Gbps

MAC addresses: 8192

„ „ MAC address table size: 64kbytes

Priority Queues: 4

Frame buffer memory: 2 Mbit

Simultaneous VLANs: 255

VLAN ID Range: 1 to 4094

IGMP multicast groups: 256

Port rate limiting

No head of line blocking

Approvals

ISO: Designed and manufactured using a ISO9001: 2000 certified quality program

CE Marking

Emissions: FCC Part 15 (Class A),

EN55022 (CISPR22 Class A)

Safety: cCSAus (Compliant with CSA C22.2 No. 60950, UL

60950, EN60950)

Laser Eye Safety (FDA/CDRH): Complies with 21

CFR Chapter1, Subchapter J.

Hazardous Locations: Class 1 Division 2

Network Management

„ HTTP graphical web-based, SSL (56-bit encryption)

„

„ Telnet, VT100, TFTP

„

„ RSA Key Management (1024 bit key)

„ Authentication and Accounting - TACACS+ (cleartext),

RADIUS client, PPP

Technical Specifications

Warranty

5 Years - Applicable to design and manufacturing related product defects.

EMI Immunity and Environmental Compliance

IEC 61000-6-2 Industrial (Generic)

„

„

IEC 61850-3 Electric Utility Substations

„

„

IEEE Compliance

802.3-10BaseT

„

„

„

„ 802.3ab-1000BaseTX

„

„

„

„ 802.1p-Class of Service

„

„

„

„

IETF RFC Compliance

RFC768-UDP

„

„

RFC791-IP

„

„

RFC793-TCP

„

„

RFC854-Telnet

„

„

RFC1112-IGMP v1

„

„

RFC1541-DHCP (client)

„

„

RFC2068-HTTP

„

„

RFC2284-EAP

„

„

RFC2865-RADIUS

„

„

IETF SNMP MIBS

„

„

RFC1907-SNMPv2-MIB

„

„

RFC2013-UDP-MIB

„

„

RFC2579-SNMPv2-TC

„

„

RFC2863-IF-MIB

„

Draft-ietf-bridge-bridgemib-smiv2-03-RSTP-MIB

„ www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

6

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

Dimensions

www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

7

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

Mounting Options

www.RuggedCom.com

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 9

Slot 10

RuggedSwitch

®

RSG2100NC

8

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

Order Codes

RSG2100NC

- ____ - _____ - ____ - ____ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - ___ - _____

Main Mount PS1 PS2 S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 MOD

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 9

Slot 10

Main: Ethernet and Power Connectors

R = Ethernet on rear; LED panel on front; power connector on rear

„

B = Ethernet on rear; LED panel on top; power connector on rear

„

Mount: Mounting Options

„ RM = 19” Rack Mount Kit

„

„

„ 00 = No Mounting Option

PS1 and PS2: Power Supply 1 and 2

(5)

„ 24 = 24VDC (10-36VDC), screw terminal block

„

„ HI = 88-300VDC or 85-264VAC, screw terminal block

„

„ 48P = 48VDC (36-72VDC), pluggable terminal block

„ HIP = 88-300VDC or 85-264VAC, pluggable terminal block

„ XX = No Power Supply (PS2 Only)

S1, S2, S3, S4, S7, S8, S9 and S10:

Ethernet Modules for Slots 1, 2, 3, 4, 7, 8, 9 and 10

„ XXXX = Empty

„

„

„

„ „ FX02 = 2 x 100FX - Multimode, 1300nm, SC

„

„

„

„ „ FX05 = 2 x 100FX - Singlemode, 1310nm, SC, 20km

„

„

„

„ FX09 = 2 x 100FX - Singlemode, 1310nm, SC, 90km

„ FX10 = 2 x 100FX - Singlemode, 1310nm, LC, 90km

S5: Gigabit Ethernet Modules for slot 5

„ XXXX = Empty

„ CG01 = 2 x 10/100/1000Tx RJ45

„

FG01 = 2 x 1000SX - Multimode, 850nm, LC, 500m

„ FG02 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 10km

„

„ FG04 = 2 x 1000LX - Singlemode, 1310nm, SC connectors, 25km

„ FG05 = 2 x 1000LX - Singlemode, 1310nm, LC connectors, 25km

„ „

„

FG50 = 2 x 1000LX SFP - Blank (no optical transceiver)

FG51 = 2 x 1000SX SFP - Multimode, 850nm, LC, 500m

(3)

„ FG52 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 10km

„ „

(3)

FG53 = 2 x 1000LX SFP - Singlemode, 1310nm, LC, 25km

(3)

„

„

FG54 = 2 x 1000LX SFP - Singlemode, 1550nm, LC, 70km

FG70 = 2 x 1000LX GBIC - Blank (no optical transceiver)

(2)(3)

„ FG71 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 10km

„ „

(4)

FG72 = 2 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km

(4)

„ FG73 = 2 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km

(2)(4)

S6: Gigabit Ethernet Modules for slot 6

„ XXXXX = Empty

„

„ „ 1FG01 = 1 x 1000SX - Multimode, 850nm, LC, 500m

„

„ „ 1FG03 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 10km

„

„ „ 1FG05 = 1 x 1000LX - Singlemode, 1310nm, LC connectors, 25km

„

„ „ 1FG51 = 1 x 1000SX SFP - Multimode, 850nm,LC, 500m

(3)

„

„

(3)

„ 1FG53 = 1 x 1000LX SFP - Singlemode, 1310nm, LC, 25km

(3)

„

„

(2)(3)

„ 1FG70 = 1 x 1000LX GBIC - Blank (no optical transceiver)

„

„

(4)

„ 1FG72 = 1 x 1000LX GBIC - Singlemode, 1310nm, SC, 25km

(4)

„ 1FG73 = 1 x 1000LX GBIC - Singlemode, 1550nm, SC, 70km

(2)(4)

MOD: Manufacturing Modifications

„ XX = None

„ C01 = Conformal Coating

Notes:

1 Distance ratings are typical but will depend on type of cabling, number of connectors and splices.

2 These transceivers have an operating temperature range of -20 °C to +85°C.

All other transceivers have an operating temperature range of -40°C to +85°C

3 SFP plugable optics that consist of a blank cage (FG50 for dual, 1FG50 for single) plus specified fiber optic interface(s) installed

4 GBIC plugable optics that consist of a blank cage (FG70 for dual, 1FG70 for single) plus specified fiber optic interface(s) installed

5 Power Supply 1 and 2 must be either both screw terminal block or both pluggable terminal block www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

9

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

Example Order Codes:

RSG2100NC-R-RM-24-48-TX01-TX01-XXXX-XXXX-XXXX-

XXXXX-XXXX-XXXX-XXXX-XXXX-XX

19” Rack mounted, 24VDC power supply, 48VDC power supply,

4 10/100 RJ45 Ethernet Ports, with Ethernet ports on the rear.

RSG2100NC-F-RM-48-48-TX01-TX01-FX01-FX01-XXXX-

XXXXX-XXXX-XXXX-XXXX-XXXX-XX

19” Rack mounted, 48VDC power supply, 48VDC, 4 10/100 RJ45

Ethernet Ports, 4 100FX (Multi Mode 1300nm Fiber) Ethernet ports, with Ethernet ports on the front.

RSG2100NC-R-RM-HI-HI-TX01-TX01-FX01-FX01-FG02-

XXXXX-FX01-FX01-FX01-FX01-C01

19” Rack mounted, HI power supply, HI power supply, 4 10/100

RJ45 Ethernet Ports, 12 100FX (Multi Mode 1300nm Fiber)

Ethernet ports, 2 1000LX (Gigabit) Ethernet ports, with Ethernet ports on the front, conformal coating.

Accessories/Options

41-11-0011 - Cable support bracket (one)

43-10-0007 - Power cable

(North America three prong connector -> beau) www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

10

RuggedSwitch

®

RSG2100NC

19-Port Modular Managed Ethernet Switch with Gigabit Uplink Ports, 56-bit Encryption

RuggedCom Inc.

300 Applewood Crescent, Unit 1,

Concord, Ontario, Canada L4K 5C7

Tel: +1 (905) 856-5288 Fax: +1 (905) 856-1995

Toll Free: 1 (888) 264-0006

Technical Support Center

Toll Free (USA & Canada): 1 (866) 922-7975

International: +1 (905) 856-5288

USA: +1 (954) 922-7975

E-mail: [email protected]

© 2010 RuggedCom Inc.

RuggedSwitch is a registered trademark of RuggedCom Inc.

Ethernet is a trademark of the Xerox Corporation.

Patent Pending

All specifications in this document are subject to change without notice.

Rev 3b — 04/27/10 www.RuggedCom.com

For additional information on our products and services, please visit our web site at: www.RuggedCom.com

RuggedSwitch

®

RSG2100NC

11

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement