M
N
O
11/10/2011
P
Q
200 240
Rack
OnLine 13
4
11
17
27
5
NEMA,
Mil*
na
Serial,
Ethernet
Powerstar UPS -Model PS10000i
10000
8000
200/41
5
Rack
OnLine 13
4
11
17
27
5
IEC, Mil*
na
Serial,
Ethernet
PS10000-GXT
NEW!!
10000
8000 208/220
rack
online
14
5
11
17
26
6
IEC, Mil,
na
serial,
Ethernet
Powerstar UPS
PS6006rm3U
NEW!!
6000
4200
160280
Rack
Online
16 5.3 5.3
17
26
4
(2) NEMA
L6-20R &
(2) L6-30R
or 5-20r
and L6-30
or MIL.
480 j
Serial,
Ethernet
Powerstar UPS -Model PS6005rm3u
5000
4000
155257
Rack
Online
26
9
5.1
17
26
6
(4)5-20,
(1) L1430r, (1)L630r or
MIL.
365j
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
Powerstar UPS -Model PS6005rm7uGlups© Shallow
depth
Powerstar UPS -Model PS6003RM-2u
5000
4000
155257
Rack
Line
26
Interacti
ve
9
12
17
16
4
2@6-20 480 joules
2@6-30 ,
Mil*, IEC*
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
3000
2700
82-144
Rack
Line
11
Interacti
ve
3
3.5
17
26
8
NEMA 5- 480 joule
15R and
5-20R, Mil
*
Serial,
*Ethernet
Display, Alarms,
Bypass, Hotswap
Powerstar UPS -Model PS6003Tower
NEW!!
3000
2700
82-144
Tower
Line
15
Interacti
ve
4
17
7.7
22
10
NEMA 5- 480 joule
15R and
5-20R, Mil
*
USB, Serial,
*Ethernet
2
3
4
Other Features
8000
Control
connections
10000
Input Voltage
Range
Powerstar UPS -Model PS-10000
1
R
Notes
L
"Backed Up"
Electrical Outlets
K
Depth
J
Width (17" fits
19" rack)
I
Height
H
Full Load runtime
G
Rated AC Energy
Absorption
F
Half Load runtime
E
Unit Type
901 Grade A
D
Mounting Options
Product name
C
Watt Rating @ PF
B
Volt-Amp Rating
A
Other Outlets
Powerstar model lineup chart
1 of 5
Display,
Expandable,
Alarms, Bypass
Display,
Expandable,
Alarms, Bypass
Dual pole circuit breaker, intelligent UPS, 1 or 2 phase
input delta power, 1 phase output, 2000W@32 minutes,
steel case
6u x26.5"d 10kva 8000w output This can be connected to
1 or 3 phase Ysystem input with 1 phase output. For
shipboard applications. Extend the temperature range to 25 to +60°C with our premium battery pack
Display,
Dual pole circuit breaker, intelligent UPS, 1 or 2 phase
Expandable,
input delta power, 2 phase output, 110 and 220 can both
Alarms, Bypass be delivered on outputs Add additional battery packs , steel
case
Display,
Dual pole circuit breaker, Dual 120/220 outputs, or single V
Expandable,
output. Steel case intelligent UPS, 1 phase input
Alarms, internal Shipboard delta power 120Lb.Net weight 1040.00 BTU/hr
Bypass (Auto and Emergency Power Off EPO, mounting rails included ,
Manual)
1200watts @32 minutes. (Opt. Add-on up to 10ea. 3Ux26"
battery trays, 200Lb Ea. 1920 VA/Hr.) NEW!!!
5
6
7
8
9
www.powerstarinc.com
www.globalspec.com/powerstar
Features: The new PS6005 UPS is loaded with features,
and packed with power performance protection. FCC
class A and UL approved. Shipboard ready, Built in internal
auto /manual bypass, Outputs both 120V and 208V.
outlets on back for both voltages.Extend the temperature
range with our premium battery pack
Global Power, Dual pole circuit breaker, intelligent UPS, 1
phase input delta power (5u) 8.75x19x22"D, 2u 240/110v
transformer *, International version
3kva 2700W shipboard UPS in low profile 2u x26"d
chassis.This unit can be ordered to MIL810F transport and
temp ratings with our Premium or N series battery. Install
an Ethernet card and use Powerchute software to control
this unit from afar.
Alphanumeric Text 3kva 2700W shipboard UPS in vertical format. Hull
Display for setup mounting kit available. Large internal Battery supply. New
and Alarms,
Text readout of status and alarms on front panel.Increase
Hotswap batteries temp ratings with our Premium or N series battery. Install
an Ethernet card and use Powerchute software to reset
units by flashing their power with the Switchable Outlet
Group Feature.
Powerstar model lineup chart
2
Line
11
pieces Interacti
can be
ve
racked
separate
ly
3
3.5
17
18
8
Powerstar UPS -- yes 3000
Model PS6003RM4u-18A,
The 2+2 grade A
NEW!!
2700
82-144
2
Line
11
pieces Interacti
can be
ve
racked
separate
ly
3
3.5
17
18
8
Powerstar UPS -Model PS-6003RM3uXL Obsolete
3000
2700
82-144
Line
15 5.4 5.3
Interacti
ve
17
26
11
Powerstar UPS -Model PS6003RM2uXL
NEW!
3000
2700
82-144
Rack
Line
15 5.4 3.5
Interacti
ve
17
26
11
PS-6003RM-3uISO
3000
2700
82-144
Rack
Line
15 5.4 5.3
Interacti
ve
17
26
11
Powerstar UPS -Model PS6003RM-5u
Shallow Depth
Powerstar UPS -Model
PS3300rm2u
IMPROVED!!
Powerstar UPS -Model
PS3300rm3uISO ELGAR
3000
2700
82-144
Rack
Line
14 4.5 8.8
Interacti
ve
17
19
8
3000
2700
120
Rack
OnLine 9.5
4
3.5
17
24
3000
2700
60-140
Rack
OnLine 9.5
4
5.3
17
24
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass,
Hotswap batteries
Only 18" deep, 3.5" tall- Battery tray is separate from 3.5"
Electronics tray- great if you are tight for space, shutdown
software, delta power dual pole breaker, EPO, MIL or
NEMA connectors , 220V model*
480 joule
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass,
Hotswap
Now being built to MIL901D-A specs. Only 18" deep, 3.5"
tall- Battery tray is separate from 3.5" Electronics tray,
Daisychain on more trays for Runtimes. delta power dual
pole breaker, EPO, MIL or NEMA connectors , 220V model
available
880 joule
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
See PS6003rm2uXL Powerchute shutdown software, 3Ux19x26"D, delta power
880 joule
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
New higher efficiency now 98% ; Very similar runtimes to
the old PS6003rm3uXL Powerchute shutdown software,
2Ux19x26.9"D, delta power dual pole breaker, EPO, mil or
NEMA connectors, add up to 10 additional 2U battery trays
880 joule
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
Powerchute shutdown software, 3Ux19x26"D, delta power
dual pole breaker, EPO, mil or NEMA connectors, Internal
Isolation transformer. Battery is similar to PS6003rm2u
performance. Stainless steel or Galvaneel chassis
880 joule
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
Powerchute shutdown software, 8.75x17x18.5"D, delta
power dual pole breaker, EPO, mil or NEMA connectors
Steel case. Shallow depth problem solver
4
L5-15, L5- IEEE 587
30, *MIL
A,B
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
Delta, Intelligent, modular, rugged welded packaging
3.5"X19X25"d, Elgar PDU connector optional Improved
motherboard now supports up to 2700W loads
4
L5-15, L5- IEEE 587
30, *MIL
A,B
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
Delta, Isolation transformer, Intelligent, modular, Stainless
steel rugged welded packaging, 5.25"X19X25"d Wired to
be controlled by Elgar 2000 PDU
11
Rack
12
13
14
15
16
17
R
480 joule
10
NEMA 515R and
5-20R, *
separate
breakers
for each
outlet
pair, *Mil
NEMA 515R and
5-20R, *
separate
breakers
for each
outlet
pair, *Mil
NEMA 515R and
520R,
battery,
*MIL
NEMA 515R and
520R,
battery,
*MIL
NEMA 515R and
520R,
battery,
*MIL
2@L6-20,
2@L6-30,
*MIL
Q
Notes
82-144
P
Other Features
2700
Powerstar UPS -Model PS6003RM-4u,
The 2+2 Shallow
depth
11/10/2011
O
Control
connections
3000
1
N
Rated AC Energy
Absorption
M
Other Outlets
L
"Backed Up"
Electrical Outlets
K
Depth
J
Width (17" fits
19" rack)
I
Height
H
Full Load runtime
G
Half Load runtime
F
Unit Type
E
Mounting Options
D
Input Voltage
Range
901 Grade A
C
Watt Rating @ PF
B
Volt-Amp Rating
A
Product name
2 of 5
www.powerstarinc.com
www.globalspec.com/powerstar
dual pole breaker, EPO, mil or NEMA connectors, add up to 10 additional battery trays
L
M
N
O
Rated AC Energy
Absorption
K
11/10/2011
P
Q
R
60-140
Rack
OnLine 9.5
4
5.3
17
24
4
MS3102r1 IEEE 587
6-10s, L5A,B
15
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass
Delta, Mil 901D, 167, 1399* accepted, Isolation
transformer, Beautiful Stainless steel fully welded chassis ,
5.25"X19X25"d, EMI/RFI gaskets & window included, ext.
Batt connector for extended runtime, EPO, Add EMI
internal filter if you need it. 4 high performance fans inside.
PS-6002rm3uXL
Obsolete see
below
2200
1980
82-147
Rack
Line
29 8.2 5.3
Interacti
ve
17
26
11
NEMA 515R and
5-20R
880
Serial,
*Ethernet
Display, Alarms,
Bypass, Hotswap
PS-6002rm2uXL
NEW!
2200
1980
82-147
Rack
Line
29 8.2 5.3
Interacti
ve
17
26
11
NEMA 515R and
5-20R
880
Serial,
*Ethernet
Display, Alarms,
Bypass, Hotswap
Powerstar UPS -Model PS-2200
2200
1980
82-144
tower
Line
24 6.5
Interacti
ve
17
8
22
6
NEMA 5- 459 joules
15, L515, *MIL
Serial,
*Ethernet
Display, Alarms,
Bypass
Powerstar UPS -- yes 2200
Model PS-2201
Grade A
1980
82-144
tower
Line
24 6.5
Interacti
ve
17
8
22
6
MS3102r1
6-10s or
NEMA
459
Serial,
*Ethernet
Display, Alarms,
Bypass
Powerstar UPS -Model PS6002rm2u
Powerstar UPS -Model
PS3200rm2u or
PS3200rm2ui
NEW!
2200
1980
82-147
Rack
17
26
11
Serial,
*Ethernet
Display, Alarms,
Bypass, Hotswap
1800
85140,
200260
Rack
17
24
6
NEMA 515R and
5-20R
L5-15,
*Mil
880
2000
Line
29 8.2 3.5
Interacti
ve
OnLine 16 5 3.5
IEEE 587
A,B
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass,
HotSwap
OBsolete This rugged 2.2 kva 1980 watt rackmount 3U x
26" deep UPS .Battery connector for external battery
packs. Extend the temperature range with our premium
battery pack
Similar specs to the discontinued PS6002rm3uXL (above)
in a 3.5" height. This rugged 2.2 kva 1980 watt rackmount
2U x 26.9" deep UPS is the new price/performance leader
with 98% efficiency for shipboard or mission critical
applications. Can also be supplied as PS6002rm2uxli
230VAC model. Modular "all-in-one" construction can have
Web-intelligent Network card added. 830W for 30
minutes. Battery connector for external 2Ux 27" battery
packs. Extend the temperature range with our Premium
battery pack
PS2200 floor standing or hull mount. with steel case. Large
battery pack gives long runtimes. Optional hull mounting kit
with steel straps and mounting plate. Also available with
208 or 230VAC in/out. NEMA 5-15r but other output
connectors available Extend the temperature range with
our premium battery pack . Same as our PS2201SS grade
A without the stainless top cover and additional
ruggedization.
Grade A -Mil 901D, 167, vibration and shock approved,
non magnetic, hull mount avail. Low smoke cable, EMI
filter, Hi-G Breaker, Tower shaped UPS, Optional
connectors
Powerchute shutdown software, 2Ux19x26"D, delta power
dual pole breaker, EPO, mil or NEMA connectors, steel
case
New increased PF! Rugged shipboard, global, or mission
critical UPS 3.5x17x19.7"d, steel case, All our true online
double conversion units can change the output frequency if
you need it. International voltage range "I" model avail.
Powerstar UPS -Model
PS3200rm-3uISO
2000
1800
85-140
or 200260v
Rack
OnLine 16
17
24
6
L5-15,
*Mil
IEEE 587
A,B
Serial,
*Ethernet
Notes
2700
Other Features
Powerstar UPS -- yes 3000
Model
PS3300rm3uLCS Grade A
1
Control
connections
"Backed Up"
Electrical Outlets
J
Depth
I
Width (17" fits
19" rack)
H
Height
G
Full Load runtime
Volt-Amp Rating
F
Half Load runtime
901 Grade A
E
Unit Type
Product name
D
Mounting Options
C
Input Voltage
Range
B
Watt Rating @ PF
A
Other Outlets
Powerstar model lineup chart
3 of 5
18
19
20
21
22
23
24
25
5
5.3
www.powerstarinc.com
www.globalspec.com/powerstar
Display, Alarms, Isolation transformer, Rugged shipboard, global, or
Bypass, HotSwap mission critical UPS, 5.25x19x23.5"d Galvaneal (zinc/iron
alloy) Steel enclosure, Delta power
Powerstar model lineup chart
F
11/10/2011
P
Q
R
1550
1350
85-140
or 200260v
Rack
OnLine 13
4
3.5
17
18
4
L5-15,
*Mil
IEEE 587
A,B
Serial,
*Ethernet
Expandable,
Alarms, Bypass
Intelligent, modular, rugged steel packaging,
3.5x16.9x19.7"d
Powerstar UPS -Model
PS3150rm-3uISO
Powerstar UPS -Model PS1504
SMT
1550
1350
60-140
Rack
OnLine 13
4
5.3
17
21
4
L5-15,
*Mil
IEEE 587
A,B
Serial,
*Ethernet
Galvanic Isolation Transformer, Galvaneal steel rugged
packaging 5.25x17x21 , countersunk top and bottom
retaining screws.
1500
980
82-144
tower
Line
23 6.5 8.5
Interacti
ve
6.75
17
8
NEMA,
*Mil
459
Serial,
*Ethernet
Display,
Expandable,
Alarms, Bypass,
HotSwap
Display, Alarms,
Bypass
Powerstar UPS -- yes 1500
Model PS1503
Grade A
980
82-144
tower
Line
23 6.5 8.5
Interacti
ve
6.75
17
6
Mil, L5-15
459
Serial,
*Ethernet
Display, Alarms,
Bypass
Powerstar UPS -Model PS1503
AVD GLUPS©
1500
980
82-144
/ 165280
tower
Line
23 6.5 8.5
Interacti
ve
6.75
17
6
Mil,
*NEMA
459
Serial,
*Ethernet
Display, Alarms,
Bypass
Powerstar UPS -- yes 1500
Model
PS6000isoA
grade A
980
82-144
Rack
Line
16
Interacti
ve
5
5.3
17
22
2
MS3102r1
6-10s
Powerstar UPS -Model
PS6000rm3uISO
Powerstar UPS -Model
PS6000rm3u220
Powerstar UPS -Model PS6000-1
rm3u
Powerstar UPS -Model PS-5021500LCD
Powerstar UPS -Model PS1501rm
Powerstar UPS -Model
PS6000rm2u
1500
980
82-144
Rack
Line
16
Interacti
ve
5
5.3
17
15
6
5-15, L5-15
1500
980
82-144
Rack
Line
16
Interacti
ve
5
5.3
17
18
4
1500
980
82-144
Rack
5
5.3
17
15
1500
865
100128
tower
10 5.3 8.7
5.1
1440
980
82-144
Rack
23 6.5 5.3
1440
980
82-144
Rack
Line
Interacti
ve
Line
Interacti
ve
Line
Interacti
ve
Line
Interacti
ve
26 7.4 3.5
Notes
Powerstar UPS -Model PS3150
1
Input Voltage
Range
Other Features
O
Control
connections
N
Rated AC Energy
Absorption
M
Other Outlets
L
"Backed Up"
Electrical Outlets
K
Depth
J
Width (17" fits
19" rack)
I
Height
H
Full Load runtime
G
Half Load runtime
E
Unit Type
D
Mounting Options
901 Grade A
C
Watt Rating @ PF
B
Volt-Amp Rating
A
Product name
4 of 5
26
27
28
This low cost UPS is the leader with power range of
1500va, 1050W output. This is a tower shaped unit. 8.5"h
x6.75"w x16.75" d. A Deck Mounting kit is available.
NEW!Text Readout on Front panel to change parameters
or read back Status or Alarms.
Best seller! Rugged stainless steel, non-magnetic, delta
power, shipboard proven 8.5x6.75x16.75"D, Mil 901D, 167,
Barge tested, AVR
29
Global power, AVD-Auto Voltage Input Detection for
CONUS and OCONUS, Rugged stainless steel, delta
power, shipboard proven 8.5x6.75x16.75"D, AVR, GLUPS
30
Serial,
*Ethernet
Display, Alarms, Best Seller! Tested for Mil901d, 461, Grade A, Isolation
Bypass, HotSwap transformer, Rugged shipboard, global, or mission critical
UPS, Mil input & output 5.25x17x21.5"d Stainless Steel
enclosure, Delta, Let us know what connectors you want.
459
Serial,
*Ethernet
Display, Alarms, Isolation Transformer, Rugged shipboard, global, or
Bypass, HotSwap mission critical UPS, 5.25x19x15"d Stainless Steel
enclosure, Delta, USB
2@ IEC
C14/13, 2
@L6-20r
459
Serial,
*Ethernet
Display, Alarms, Output Transformer, 220V output 110V input, Rugged
Bypass, HotSwap shipboard, global, or mission critical UPS, 5.25x19x18"d
Stainless Steel enclosure, Delta, USB
6
5-15, L515
459
Serial,
*Ethernet
14
6
5-15
340
USB
17
18
2
Mil,
*NEMA
459 joules
Serial,
*Ethernet
17
18
6
5-15, L515
459
Serial,
*Ethernet
Display, Alarms, Rugged shipboard, global, or mission critical UPS,
Bypass, HotSwap 5.25x19x15"d Stainless Steel enclosure, Delta, USB no
isolation transformer
LCD Display,
Low Cost unit, Hi-temp battery with 8-10 year life, Auto
Alarms
Voltage regulator. 8.7x5.1x13.8”. Wired for shipboard
power, dual pole breaker Stepped Full Sinewave output
Display, HotSwap, Stainless steel chassis Dual pole circuit breaker, delta
Alarms, Bypass power, modular design non-magnetic, SNMP ready,
Isolation Transformer opt., Hi temp batteries avail.
Display, Alarms, Rugged shipboard UPS, 3.5x19x18"d Steel enclosure,
Bypass, HotSwap Delta,USB
31
32
33
34
35
36
37
16
www.powerstarinc.com
www.globalspec.com/powerstar
Powerstar model lineup chart
11/10/2011
6.9
15
4
5-15, L515, *Mil
IEEE 587
A,B
USB,
*Ethernet
2.3 3.5
7.1
14
5
5-15
365
USB
3.5
17
17
4
5-15, L515, *Mil
IEEE 587
A,B
USB,
*Ethernet
6
3.5
17
17
4
5-15, L515, *Mil
IEEE 587
A,B
USB,
*Ethernet
OnLine 17
6
5.3
17
17
4
5-15, L515, *Mil
IEEE 587
A,B
USB,
*Ethernet
OnLine 17
6
3.5
17
15
1
NEMA,
*mil
IEEE 587
A,B
Serial
12.6
7
4
5-15
365
USB
750
450
Powerstar UPS -Model PS503
Convertible
Powerstar UPS -Model
PS3070rm2u
Powerstar UPS -Model
PS3070rm3uISO
Powerstar UPS -Model PS-700VI
Powerstar UPS -Model PS-502650
700
630
60-140 Rack or OnLine 17
tower
6
700
630
60-140
Rack
OnLine 17
700
630
60140,
240
Rack
700
630
95 to
255
Rack
650
390
105128
STRIP
Line
Interacti
ve
6
Q
R
Notes
P
Other Features
O
Control
connections
Half Load runtime
N
Rated AC Energy
Absorption
Unit Type
M
8.9
900
STRIP
L
4
1000
105128
K
Other Outlets
Mounting Options
60-140 Rack or OnLine 12
tower
J
"Backed Up"
Electrical Outlets
I
Depth
H
Width (17" fits
19" rack)
G
Height
F
Full Load runtime
E
Input Voltage
Range
901 Grade A
D
Powerstar UPS -Model PS5031000 Tower
Powerstar UPS -Model PS-502750G
1
38
C
Watt Rating @ PF
B
Volt-Amp Rating
A
Product name
5 of 5
Expandable,
Alarms, Bypass,
HotSwap
Alarms
Delta, Auto and Manual bypass, Full sine, all the features
of a Much more expensive UPS in a lower power level.
Expandable,
Alarms, Bypass,
HotSwap
Expandable,
Alarms, Bypass,
HotSwap
Expandable,
Alarms, Bypass,
HotSwap
Delta, Auto and Manual bypass, 3.5x19x17"d Full sine
output, USB, All the features of the larger High powered
UPS with the Low Cost Solution
Delta, Auto and Manual bypass, 3.5x19x17"d Full sine
Expandable,
Alarms, Bypass,
HotSwap
Alarms
Delta, All metal shell for rugged operation, shielded
connectors Global UPS (GLUPS) Rack Mount
Low cost, 3.48x7.09x13.49" 3 outlets have hibernate state
'Master control' Dual breaker Delta power wired, for PC,
Brick shape thick shock resistant plastic case. This will
connect directly to USB and Windows will recognize it with
no additional software for controlled shutdown during
Power Failure. Great for a PC and Display. Quasi Sine
39
40
41
42
43
44
Most See
units notes
can
col. R
also
be
built in
Euro
voltag
es
230V.
Line
Interacti
ve
8
4.2 3.5
Standard
outlets
listed.
Most units
can be
optioned
with Mil
Spec
connectors
.
USB is
provided on
most all units.
Some contain
DB9 Serial as
well. Ethernet
is optional on
most units.
SNMP, HTTP,
45
www.powerstarinc.com
www.globalspec.com/powerstar
Galvanic isolation transformer, auto and manual bypass,
5.25x19x 17"d, 240 or 120V GLUPS©
Low Cost, Delta wired Dual pole breaker, USB cable
included , shutdown PC Software , Brick shaped plastic
case.Windows knows this UPS if connected with USB.
Features; Full
, All Rack units come with Steel mounting rail kits for
Sinewave output, installing into a 19" 4 post equipment rack. The Floor
Internal
mount towers can be purchased with a steel weldable
Diagnostics ,
foundation plate with padded metal straps to securely
Remote shutdown hold the unit in place.
capability,
Software to
monitor and adjust
UPS included. ,
Audible or visual
or remote alarm
outputs. Display
means LED or LCD
indicators
showing unit
status