BEGA
BEGA
Tools Required:
Dimensions
BEGA Fixtures supplied with Round
Adaptor Plates – Kit #3
CSA certified to U.S. and Canadian standards.
Suitable for wet locations.
Weight: 4.2 lbs.
Notice to Installer for 3503LED:
1. See page 2 for specific product safety warnings.
2. BEGA luminaires may be damaged if connected to conduit systems containing water- Article 300-5G of National Electric Code requires that “Conduits or raceways through which moisture may contact energized live parts shall be sealed or plugged at either or both ends”.
3. Mounts directly to a standard octagonal 4” wiring box (by others) using BEGA mounting kit (supplied).
NOTE: Recommended that installer uses (2) screws (by others) to lock in place back housing, along with BEGA mounting kit, to wall surface for eased installation. (Fig. 3)
4. In conformance with U.L. Standards 1598, a silicone-based sealant MUST be
used between the mounting plate edge and supporting wall.
5. LEDs are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation.
3503LED - installation:
1. Loosen 3mm set screw on luminaire outer trim ring and turn ring to the stop (ccw). Remove trim ring with glass from luminaire base.
2. Loosen (2) hex screws on LED module plate and CAREFULLY remove LED module - trying not to come into direct contact with the LED chips.
3. Feed luminaire wires through fixture base, IP nipple (provided), and center hole in mounting strap.
4. Make supply wiring and luminaire wiring connections in the octagonal wiring box:
MAIN VOLTAGE SUPPLY WIRE TO BLACK LUMINAIRE WIRE
NEUTRAL (COMMON) SUPPLY WIRE TO WHITE LUMINAIRE
WIRE GREEN GROUND WIRE TO GREEN LUMINAIRE WIRE
Dimming (if applicable):
DIMMING CONTROL WIRE (+) TO POSITIVE DRIVER DIM CONTROL WIRE
DIMMING CONTROL WIRE (-) TO NEGATIVE DRIVER DIM CONTROL WIRE
5. Attach mounting strap (provided) to wiring box using outlet box screws (by others).
6. Place a small bead of silicone around the back side of the luminaire base that will come in contact with the finished wall (exterior applications only).
7. Attach 1/4” nipple to mounting strap and place luminaire over nipple.
8. Use lockwasher and nut (provided) to secure luminaire on nipple. Tighten nut. Use (2) screws (by others) to lock back housing into place for ease of trim ring installation. Refer to Figure 3 for screw hole locations.
9. Replace the LED module carefully along with luminaire lens and trim ring. Turn trim ring to the stop (cw) and tighten outer set screw to secure.
8-1/4”
B:
3-1/8”
Outlet Box
Mounting
Screws
Fixture Back
Adaptor Plate
Outlet Box
Screw
Lock
Washer
Hex Nut
Mounting
Screws
Outlet Box
Screw
Ground Screw
Note: In conformance with
UL Standard 1598, a silicone
based sealant must be used
between fixture and supporting wall.
BEGA 1000 BEGA Way, Carpinteria CA 93013 (805) 684-0533 FAX (805) 684-6682
99029 6/01
Installation
Figure 2: WallInstructions
mount
FigureBEGA
1: Ceiling mount
Installation Instructions
Outlet Box
BEGA Fixtures Supplied with Mounting
Strap and 1⁄ 4“ I.P.Nipple – Kit #2
Mounting Strap
Outlet Box
Screw
Fixture Back
1. Attach mounting strap to outlet box with outlet
box screws.
2. Connect wires from the BEGA fixture to
building wires inside outlet box. Connect black
fixture wire to black supply wire. Connect white
fixture wire to white supply
wire.
3. Secure ground wire to green ground screw
or green fixture wire.
4. Slip fixture over 1⁄4” I.P. Nipple attached to
mounting strap as shown.
5. Secure fixture to mounting strap and
building using lock washer and hex
nut provided.
Note: In conformance with
UL Standard 1598, a silicone
based sealant must be used
between fixture and supporting wall.
1
⁄4” I.P.
Lockwasher
and nut
⁄4 ” I.P.
Nipple
1
Outlet Box
Screw
Ground Screw
99029
BEGA 1000 BEGA Way, Carpinteria CA 93013 (805) 684-0533 FAX (805) 684-6682
Figure 3: Secondary
Wall Mount Screw
Holes
Accessories
Please refer to the appropriate
accessory installation sheet for
further instruction when applicable.
Lamp: 8.4W LED
A:
1. Install mounting screws into adaptor plate and
attach adaptor plate to outlet box.
2. Connect wires from the BEGA fixture to
building wires inside outlet box. Connect black
fixture wire to black supply wire. Connect white
fixture wire to white supply wire.
3. Secure ground wire to green ground screw
or green fixture wire.
4. Slip fixture over screws attached to
mounting strap.
5. Secure fixture to mounting strap and
building using lock washers and hex
nuts provided.
Protection Class: IP65
No relamping necessary.
Installation Instructions
Installation Instructions
2.5mm hex key
3mm hex key
Phillips head screw driver medium
Relamping/Maintenance
3503LED
Impact-resistant LED ceiling and wall luminaire
Installation and Technical Information
6/01
Replacement Parts
Description
Part No
Lens
Gasket
LED driver (0-10V)
LED replacement (3000K)
LED replacement (4000K)
11286411
831313
75939
LED-0338/830
LED-0338/840
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2014
3503LED
8/13/2014
Page 1 of 2
BEGA
Installation and Technical Information
Impact-resistant LED ceiling and wall luminaire
3503LED
Product Safety Warnings:
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
SUITABLE FOR WET LOCATIONS.
MIN 90°C SUPPLY CONDUCTORS.
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D’INSTALLATION PERTINENT, PAR UNE PERSONNE QUI CONNAÎT
BIEN LE PRODUIT ET SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.
CONVIENT AUX EMPLACEMENTS MOUILLÉS.
LES FILS D’ALIMENTATION 90°C MIN.
In the interest of product improvement, BEGA reserves the right to make technical changes without notice.
BEGA 1000 Bega Way, Carpinteria, CA 93013 (805)684-0533 Fax (805)566-9474 www.bega-us.com © Copyright BEGA-US 2014
3503LED
8/13/2014
Page 2 of 2