power quality analyzer pw3198 power quality analyzer pq3100

*For more detailed information, please refer to the individual product catalogs.
POWER QUALITY ANALYZER PQ3100
QUICK SET function
Order Code: PQ3100 (Main unit only)
PQ3100-91 (includes 600 A sensor × 2, SD card, Carrying case)
PQ3100-92 (includes 600 A sensor × 4, SD card, Carrying case)
PQ3100-94 (includes 6000 A sensor × 4, SD card, Carrying case)
POWER QUALITY ANALYZER PW3198
Transient over voltage
DMM display
Order Code: PW3198 (Main unit only)
PW3198-90 (bundled with the PQA-HiVIEW PRO 9624-50)
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
PQ3100
Model
Measurement lines
Fundamental frequency
Number of channels
Measurement range
Voltage
input
Basic accuracy
Max. rated voltage to earth
Number of channels
PW3198
Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire + CH4
DC/ 50 Hz/ 60 Hz
DC/ 50 Hz/ 60 Hz/ 400 Hz
4 (U4: Not isolated)
4 (U4: Isolated from U1 to 3)
1000 V
600 V
CAT IV 600 V
4
500.00mA AC to 5.0000kA AC
Measurement range
Current
(depends on current sensor in use)
input
±0.2% rdg.±0.1% f.s. + clamp sensor accuracy
Basic accuracy
N/A
Power supply for sensors
1/2 RMS value (half-wave offset wave calculation), RMS value, waveform peak, Voltage DC,
Unbalance factor (negative-phase, zero-phase), frequency (1 wave/ 200 ms/ 10 sec.)
Voltage
Crest factor
N/A
Inrush current (half-wave), RMS value, waveform peak, Current DC, Unbalance factor (negative-phase, zero-phase), K factor
Current
1/2 RMS value (half-wave offset wave calculation), crest factor
N/A
Measurement
Active power, Reactive power, Apparent power, Power factor, Displacement power factor, Active energy, Reactive energy
Power
parameters
Apparent energy, Electrical charges
N/A
Available in future firmware update
(simultaneous measurement of 3 channels)
Flicker
0 th (DC) to 50 th orders, voltage/current/power, Phase angle (voltage/current), Voltage-current phase angle, Total harmonic distortion factor (voltage/ current)
Harmonic
0.5 th order to 49.5 th order, voltage/ current
Inter harmonic
N/A
2 kHz to 80 kHz
High-order harmonic component
Max. 1 year
Max. 1 year (55 weeks with repeat function on)
Record
Time series
measurement Recording interval
200/ 600 ms/ 150 cycles (with 50 Hz input), 1/ 2/ 5/ 10/ 15/ 30 s to 2 h
150 cycles (with 50 Hz input), 1/ 3/ 15/ 30 s to 2 h
9999 events × 365 days of repeat operation
1000 events × 55 repeats
Maximum number of recordable events
Display of the number of events per day by event type
Event
N/A
Event statistical processing
measurement
Before
event:
Max.
1s/
At
event:
200ms/
After
event:
Max.
10s
Before
event:
N/A
/
At
event:
200ms/
After
event: Max.1 s (with series of events)
Waveform acquisition
Event
parameters
Measurable event
parameters
Transient over voltage
Setting assistance
Operating temperature and humidity
IEC 61000-4-30 standard compliance
Interfaces
Power supply
Continuous operating time
Dimensions
Mass
Accessories
CAT III 1000 V, CAT IV 600 V
4
50.000mA AC to 5.0000kA AC, 10.000A DC to 2.0000kA DC
(depends on current sensor in use)
±0.1% rdg.±0.1% f.s. + clamp sensor accuracy
RMS value/ Voltage waveform peak/ Current waveform peak/
Comparison of voltage waveforms/ Harmonics/ Unbalance factor/ Power
200 kS/s, 2.2 kV
2 MS/s, 6 kV
Quick Set
Simple Setting feature
-20
to 50
(-4 to 122 ), 80% RH
0 C to 50 C (32 to 122 ), 80% RH
Class S
Class A
SD/SDHC memory card, RS-232C, USB, LAN
AC Adapter Z1002 (100 to 240V, 50/60Hz), Battery Pack Z1003
8h
3h
300 mm (11.81 in) W × 211 mm (8.31 in) H × 68 mm (2.68 in) D
2.5 kg (88.2 oz) (including battery pack)
2.6 kg (91.7 oz) (including battery pack)
AC Adapter Z1002, Battery Pack Z1003, Strap, USB cable, Instruction manual, Measurement guide, Spiral tube
Voltage Cord L1000-05, PQ ONE (software, CD)
Voltage Cord L1000, Input Cable Labels, SD memory card 2GB Z4001
N/A