Data Sheet - Wiegand to RS-485 Converter.cdr

Wiegand to RS-485 Converter
Specifications
Supported Formats:
Ÿ Wiegand 26
Ÿ Wiegand 34
Selectable Modes:
Ÿ ASCII Mode: Output of card ID as Serial string,
terminated by <CR><LF>. Point-to-Point only.
Ÿ Modbus RTU: Number of read Wiegand bits,
Card ID and Modbus error counter are accessible
as Holding Registers. Mul -drop support.
Baud Rates:
Ÿ 4800
Ÿ 9600
Ÿ 19200
Ÿ 38400
Overview
Interfaces equipment like
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Ÿ
Electronic Access Control Systems,
Security Systems,
Contactless Card Readers,
Keypads,
Biometric Readers,
and RFID terminals
with
Ÿ
Ÿ
Ÿ
Ÿ
Remote Terminal Units,
PLCs,
PCs,
or SCADA systems.
Supports Modbus RTU and serial ASCII output of
Wiegand card number.
Applica on include:
Ÿ Electronic Signatures (FDA regulates processes)
Ÿ Time & A endance (machine or process access)
Ÿ Equipment Security (control rooms, data centers)
Data Formats:
Ÿ 8 data bits, no parity, 2 stop bits
Ÿ 8 data bits, even parity, 1 stop bit
Ÿ 8 data bits, odd parity, 1 stop bit
Ÿ 8 data bits, no parity, 1 stop bit
Inputs (removable terminal blocks):
Ÿ Supply Voltage: 16VDC - 36VDC, 0.5A - 3A (up to
3A when reader is powered by module)
Ÿ Wiegand Signal: D0, D1, GND
Outputs (removable terminal blocks):
Ÿ 12VDC, 2.5A Reader Power
Ÿ RS-485 serial port
Indicators
Ÿ Power LED, briefly dims when valid Wiegand data
was received and processed.
Installa on
Ÿ DIN Rail
Wiegand to RS-485 Converter
Dimensions
Connections
24V DC IN
- - + +
Reader
Wiegand IN
117.2mm (4.61”)
105.7mm (4.16”)
Power
DI GND GND D0
RS-485
PC, PLC,
RTU, SCADA
A+ GND GND B-
107mm (4.21”)
22.5mm
(0.89”)
113.6mm (4.47”)
12V DC OUT
- - + +
DIP Switch Settings
Baud Rate
Data Format
1
2
Device ID
ASCII
Mode
(255)
8N2
4800
Modbus Holding Registers
3
4
1
2
3
27
26
25 24
4
5
6
7
8
23
22
21
20
Modbus RTU Mode
9600
8E1
1
2
19200
3
4
Modbus
ID = 1
8O1
1
2
38400
3
4
2
3
2
3
26
25 24
4
5
6
7
8
23
22
21
20
Descrip on
Access
0 (40001)
1 (40002)
2 (40003)
3 (40004)
Number of read Wiegand Bits
HighWord of Card ID
LowWord of Card ID
Modbus Error Counter
Read/Write
Read/Write
Read/Write
Read only
Modbus
ID = 2
8N1
1
1
27
Register
1
2
3
27
26
25 24
4
5
6
7
8
23
22
21
20
4
Modbus
ID = 3
1
2
3
27
26
25 24
4
5
6
7
8
23
22
21
20
Note: DIP switch se ngs are read on power-up.
Valid Modbus Device IDs: 1 - 247.
Integrasense, Inc.
V1.0
5 Birch St. Unit 2
Wilmington, MA 01887
© 2017 Integrasense, Inc. All rights reserved.
603-577-8830
info@integrasense.com
Integrasense is a trademark of Integrasense, Inc.
All other product and company names are trademarks or registered
trademarks of their respec ve owners.
Specifica ons are subject to change without no ce.
Download PDF