UNIVERGE OW5000 Installation Guide (R4.1)

UNIVERGE OW5000 Installation Guide (R4.1)
UC for Enterprise (UCE)
Application Platform
UNIVERGE OW5000
Network Application Middleware
Installation Guide
NEC NEC Corporation
NDA-31087
Issue 1
March 2010
Liability Disclaimer
NEC Corporation reserves the right to change the specifications,
functions, or features, at any time, without notice.
NEC Corporation has prepared this document for the exclusive use of
its employees and customers. The information contained herein is the
property of NEC Corporation and shall not be reproduced without prior
written approval from NEC Corporation
NEAX® and Dterm® are registered trademarks of NEC Corporation.
© 2010 NEC Corporation
Microsoft and Windows are registered trademarks of
Microsoft Corporation.
All other brand or product names are or may be trademarks or
registered trademarks of, and are used to identify products or services
of, their respective owners.
i
Contents
Introduction
1-1
UNIVERGE OW5000 Installation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
How This Guide is Organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
UNIVERGE OW5000 Platform
2-1
Before Installing OW5000 Platform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Requisite Task before Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# 1 Administrator Rights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# 2 IIS and ASP.NET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# 3 .NET Framework 3.5 SP1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# 4 Windows PowerShell (1.0) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# 5 Microsoft Windows Installer 4.5 (Microsoft Windows Server 2003 only). . .
# 6 Microsoft SQL Server 2005/2008 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# 7 Install WCF Activation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
# 8 Windows Update. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-1
2-2
2-3
2-4
2-5
2-5
2-6
2-6
2-6
2-6
Installing the OW5000 Platform. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
OW5000 Platform License Activation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-15
US, Australia, and European Market . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing License Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring License Manager Information in OW5000 Administrator. . . . . . .
Asian and Russian Market . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Creating a Hardware Key Code File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Registering to the Software License Activation Center. . . . . . . . . . . . . . . . . .
License Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
License Install . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Confirming the Installed License. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-15
2-16
2-16
2-17
2-18
2-19
2-19
2-20
2-22
Hardware Replacement Process (Asian and Russian Markets only) . . . . . . . 2-23
Uninstalling the OW5000 Platform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-24
UCE Application Platform (UNIVERGE OW5000) Installation Guide
ii
Contents
Upgrading the OW5000 Platform from R2/R3. . . . . . . . . . . . . . . . . . . . . . . . . 2-26
Stopping a Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Upgrading the Platform from an older Version . . . . . . . . . . . . . . . . . . . . . . . .
Installing License Manager Client (US, Australia and Europe only) . . . . . . . .
Installing the New Software Licenses (US, Australia, and Europe only). . . . .
OW5000 Platform License Activation (Asian and Russian Market) . . . . . . . .
Create a Hardware Key Code File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Registering to the Software License Activation Center. . . . . . . . . . . . . . . . . .
Uninstalling the R3 License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing R4 License. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2-26
2-27
2-33
2-33
2-34
2-34
2-35
2-36
2-37
Upgrading the OW5000 Platform from an Older Version of R4. . . . . . . . . . . . 2-37
Stopping a Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Upgrading the OW5000 Platform . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuring the Current Platform Version (US, Australia and 
Europe Markets) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Asian and Russian Markets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OW5000 Remote Call Control Service
2-37
2-38
2-41
2-41
3-1
Installing the OW5000 Remote Call Control Service. . . . . . . . . . . . . . . . . . . . . 3-1
OW5000 Access Server
4-1
Installing OW5000 Access Server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
Log Viewer
5-1
Installing Log Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
DB Tool
6-1
Installing DB Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Contents
Backup and Rollback Procedure
iii
A-1
Current Version Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Export Current Version Registry Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Backup Current Version Database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Rollback Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
Uninstall R4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Delete NECAM Registry Key (R4) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Restore NECAM Registry Key (old version) . . . . . . . . . . . . . . . . . . . . . . . . . . .
Install Platform and Other Applications (old version) . . . . . . . . . . . . . . . . . . . .
Restore OW5000 database (old version) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Microsoft SQL Server 2008 Express
Edition with Advanced Services
A-4
A-4
A-5
A-5
A-5
B-1
Microsoft SQL Server 2008 Express Edition with Advanced Services Install . . B-1
Microsoft SQL 2008 Express Edition Uninstall . . . . . . . . . . . . . . . . . . . . . . . . B-16
UCE Application Platform (UNIVERGE OW5000) Installation Guide
iv
Contents
UCE Application Platform (UNIVERGE OW5000) Installation Guide
v
Figures
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
2-9
2-10
2-11
2-12
2-13
2-14
2-15
2-16
2-17
2-18
2-19
2-20
2-21
2-22
2-23
2-24
2-25
2-26
2-27
2-28
2-29
2-30
2-31
2-32
2-33
2-34
2-35
Microsoft Windows Installer 4.5 Prompt . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
OW5000 Platform Installer dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Welcome Dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Software License Agreement dialog box . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Customer Information dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Sales Region Selection dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
Installation Destination Folder dialog box . . . . . . . . . . . . . . . . . . . . . . . 2-11
Change Current Destination Location dialog box . . . . . . . . . . . . . . . . . 2-11
User Name / Password dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
Database Server dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-13
Installing OW5000 Platform dialog box . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
Installation Complete dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-14
License Manager Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-16
Licensed Information (Confirmation) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-17
Hardware Key Code Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
Confirming the File Path dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-18
Hardware Key Code Confirmation dialog box . . . . . . . . . . . . . . . . . . . . 2-19
UNIVERGE OW5000 License Activator dialog box . . . . . . . . . . . . . . . . 2-20
License Activator—Main dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-22
Confirm Component Removal dialog box . . . . . . . . . . . . . . . . . . . . . . . 2-24
Remove OW5000 Platform dialog box . . . . . . . . . . . . . . . . . . . . . . . . . 2-27
Watch Dog Error Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27
OAIMonitor Error Message . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-27
Confirm Component Removal dialog box . . . . . . . . . . . . . . . . . . . . . . . 2-28
Removing Programs dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28
Remove Shared File dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-28
Remove Shared File Confirmation dialog box . . . . . . . . . . . . . . . . . . . . 2-29
OW5000 Platform Removal Confirmation dialog box . . . . . . . . . . . . . . 2-29
Check Database for Upgrading dialog box . . . . . . . . . . . . . . . . . . . . . . 2-29
OW5000 Database Utility dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30
Database Upgrading dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-30
Logon Information dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-31
Ready to Upgrade the Program dialog box . . . . . . . . . . . . . . . . . . . . . . 2-31
Upgrading OW5000 Platform dialog box . . . . . . . . . . . . . . . . . . . . . . . . 2-32
Install Completed dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-32
UCE Application Platform (UNIVERGE OW5000) Installation Guide - Revision 3
vi
Figures
2-36
2-37
2-38
2-39
2-40
2-41
2-42
2-43
2-44
2-45
2-46
2-47
3-1
3-2
3-3
3-4
3-5
3-6
3-7
3-8
4-1
4-2
4-3
4-4
4-5
4-6
4-7
4-8
4-9
5-1
5-2
5-3
5-4
6-1
6-2
6-3
6-4
A-1
A-2
A-3
A-4
A-5
B-1
B-2
B-3
Settings dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-33
Activation Flow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
Hardware Key Code Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-34
Hardware Keycode Confirmation dialog box . . . . . . . . . . . . . . . . . . . . . 2-35
Hardware Key Code Created dialog box . . . . . . . . . . . . . . . . . . . . . . . . 2-35
UNIVERGE OW5000 License Activator dialog box . . . . . . . . . . . . . . . . 2-36
OW5000 License Activator dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . 2-36
OW5000 Database Utility dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-38
Logon Information dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
OW5000 Platform Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-39
Upgrading in Progress dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-40
Setup Complete dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-40
Warning dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Remote Call Control—Welcome dialog box . . . . . . . . . . . . . . . . . . . . . . 3-2
License Agreement dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Ready to Install dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
Installing Remote Call Control dialog box . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Installation Complete dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Patch Installation Wizard dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Remote Call Control—Patch Complete dialog box . . . . . . . . . . . . . . . . . 3-5
Access Server—Welcome dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
License Agreement dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Destination Folder dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Database Server dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
Server Information dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Ready to Install dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Installing Access Server dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Installation Complete dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-6
Services Window—AccessServer dialog box . . . . . . . . . . . . . . . . . . . . . 4-7
Log Viewer—Welcome dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Destination Folder dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
Ready to Install dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
Installation Complete dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3
DB Tool—Welcome dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Destination Folder dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Ready to Install dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-3
Installation Complete dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-4
Backup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
Registry Editor dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Rollback Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-4
Property dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-7
Property dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-8
Extracting Files dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
SQL Express Install dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
Installation Options dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-3
UCE Application Platform (UNIVERGE OW5000) Installation Guide - Revision 3
Figures
B-4
B-5
B-6
B-7
B-8
B-9
B-10
B-11
B-12
B-13
B-14
B-15
B-16
B-17
B-18
B-19
B-20
B-21
B-22
B-23
B-24
B-25
B-26
B-27
B-28
B-29
B-30
B-31
vii
Setup Support Rules dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-4
Product Key dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Software License Agreement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-5
Setup Support Files dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-6
Feature Selection dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-7
Instance Configuration dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Disk Space Requirements dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . B-8
Server Configuration dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-9
Database Engine Configuration dialog box . . . . . . . . . . . . . . . . . . . . . . B-10
Reporting Services Configuration dialog box. . . . . . . . . . . . . . . . . . . . . B-11
Error and Usage Reporting dialog box . . . . . . . . . . . . . . . . . . . . . . . . . B-11
Installation Rules dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-12
Ready to Install dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-12
Installation Progress dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13
Complete dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-13
Named Pipes popup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-14
SQL Server Configuration Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . B-14
SQL Server Browser Service—Automatic Startup Mode. . . . . . . . . . . . B-15
Uninstall SQL 2008 Express Server . . . . . . . . . . . . . . . . . . . . . . . . . . . B-16
Remove dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-16
Setup Support Rules dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-17
Select Instance dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-17
Select Features dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-18
Removal Rules dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-18
Ready to Removed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-19
Removal Progress dialog box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-19
Removal Progress—Continued dialog box . . . . . . . . . . . . . . . . . . . . . . B-20
SQL Server 2009 Removal Confirmation dialog box . . . . . . . . . . . . . . . B-20
UCE Application Platform (UNIVERGE OW5000) Installation Guide - Revision 3
viii
Figures
UCE Application Platform (UNIVERGE OW5000) Installation Guide - Revision 3
ix
Tables
Table
2-1
2-2
2-3
Title
Page
Requirements for OW5000 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Requisite Components and Tasks
. . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Sales Regions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
UCE Application Platform (UNIVERGE OW5000) Installation Guide
x
Tables
UCE Application Platform (UNIVERGE OW5000) Installation Guide
1-1
1
Introduction
The UNIVERGE OW5000 Installation Guide provides the information you
need to install the OW5000 Platform and related services and tools.
The following topics are included in this chapter:
Chapter Topics
• UNIVERGE OW5000 Installation Guide
• How This Guide is Organized
UNIVERGE OW5000 Installation Guide
OW5000 is a collaboration middleware allowing easy application
development in which to communicate with the IP Telephony
environment.
How This Guide is Organized
Chapter 1
Introduction
This chapter outlines how to use the manual including the organization
and chapter layout of the UNIVERGE OW5000 Installation Guide.
Chapter 2
UNIVERGE OW5000
Platform
This chapter describes the installation of the OW5000 Platform and the
OW5000 components.
Chapter 3
OW5000 Remote Call Control
Service
This chapter describes the installation process of the Remote Call
Control Service. Remote Call Control provides an interface to collaborate
with Microsoft LCS/OCS.
Chapter 4
OW5000 Access Server
Chapter 5
Log Viewer
Chapter 6
DB Tool
This chapter describes the installation process of the OW5000 Access
Server. The OW5000 Access Server provides a SIP Presence interface.
This chapter describes the installation process of the Log Viewer. The
Log Viewer allows an administrator to view events logged by other
applications and to open log files to query, filter, and display their
contents.
This chapter describes the installation process of the DB Tool. The DB
Tool provides a system administrator the capability to import and export
data between the OW5000 databases and text files.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
1-2
Introduction
Appendix A
Backup and Rollback
Procedure
This chapter describes backup procedures when upgrading from an
older version of the OW5000 to a newer version. This procedure allows
you to revert back to the older version, if necessary.
Appendix B
Microsoft SQL Server 2008
Express Edition with
Advanced Services
This chapter describes the procedures for installing and uninstalling the
SQL 2008 Express Server.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-1
2
UNIVERGE OW5000 Platform
This chapter describes the installation process of the OW5000 Platform
software.
The following topics are included in this chapter:
Chapter Topics
•
•
•
•
•
•
•
Before Installing OW5000 Platform
Installing the OW5000 Platform
OW5000 Platform License Activation
Hardware Replacement Process (Asian and Russian Markets only)
Uninstalling the OW5000 Platform
Upgrading the OW5000 Platform from R2/R3
Upgrading the OW5000 Platform from an Older Version of R4
Before Installing OW5000 Platform
Requirements
Table 2-1 lists the requirements for the OW5000 system. For more
information, refer to the UNIVERGE OW5000 Getting Started Guide.
Table 2-1 Requirements for OW5000 System
Requirement
Minimum Version/Size
Action
RAM
1 GB
Abort
HDD
10 GB
Abort
6.0
Abort
3.5 SP1
Install .NET Framework 3.5
IIS
.NET Framework
OS
ASP.NET registered in IIS
Microsoft Windows Server 2003
Standard or Enterprise Edition,
Abort
Microsoft Windows Server 2008
Standard or Enterprise Edition
3.5
Password for Services Logon User Must not be blank
Network Interface Card
Must exist
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Register ASP.NET in IIS
Abort
Abort
2-2
UNIVERGE OW5000 Platform
Requisite Task before Installation
The requirements are different depending on the servers OS type which
is installed for OW5000 Platform/Access Server. Perform the requisite
tasks before the OW5000 Platform install by following the table below.
Table 2-2 Requisite Components and Tasks
Microsoft Windows Server 2003 and 2003 R2, x86/64
Component
Folder
Platform
AccessServer
ASP .NET 3.5
Install from Windows feature
X
-
Microsoft Internet
Information Server (IIS)
6.0, 7.0 or higher
Install from Windows feature
X
-
X
-
X
-
X
-
X
X
Windows PowerShell 1.0
(x86)
\PowerShell\x86\WindowsSer
ver2003-KB926139-v2-x86ENU.exe
(x64)
\PowerShell\x64\WindowsSer
ver2003.WindowsXPKB926139-v2-x64-ENU.exe
(x86)
\MSSQL\x86\SQLEXPRADV_
SQL Sever 2008 Express x86_ENU.exe
Edition with Advanced
(x64)
Services
\MSSQL\x64\SQLEXPRADV_
x64_ENU.exe
Microsoft Windows
Installer 4.5
.NET Framework 3.5
(x86)
\WindowsInstaller\x86\Wi
ndowsServer2003KB942288-v4x86.exe
(x64)
\WindowsInstaller\x64\Window
sServer2003-KB942288-v4x64.exe
\dotnetfx\dotnetfx35setup.exe
Microsoft Windows Server 2008 x86/x64
Component
Folder
Platform
AccessServer
ASP .NET 3.5
Install from Server Manager
X
-
WCF Activation
Install from Server Manager
X
-
Microsoft Internet
Information Server (IIS)
6.0, 7.0 or higher
Install from Server Manager
X
-
Windows PowerShell 1.0 Install from Server Manager
X
-
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-3
Microsoft Windows Server 2008 x86/x64
Component
Folder
Platform
AccessServer
(x86)
\MSSQL\x86\SQLEXPRADV_
SQL Sever 2008 Express x86_ENU.exe
Edition with Advanced
Services
(x64)
\MSSQL\x64\SQLEXPRADV_
x64_ENU.exe
X
-
Microsoft Windows
Installer 4.5
Install from Server Manager
X
-
.NET Framework 3.5
\dotnetfx\dotnetfx35setup.exe
X
Microsoft Windows Server 2008 R2
Component
Folder
Platform
AccessServer
ASP .NET 3.5
Install from Server Manager
X
-
WCF Activation
Install from Server Manager
X
-
Microsoft Internet
Information Server (IIS)
6.0, 7.0 or higher
Install from Server Manager
X
-
Windows PowerShell 1.0 Install from Server Manager
X
-
(x86)
\MSSQL\x86\SQLEXPRADV_x
SQL Sever 2008 Express 86_ENU.exe
Edition with Advanced
Services
(x64)
\MSSQL\x64\SQLEXPRADV_x
64_ENU.exe
X
-
Microsoft Windows
Installer 4.5
Install from Server Manager
X
-
.NET Framework 3.5
Install from Server Manager
X
X
Before installing the OW5000 Platform, ensure the following procedures
have been completed (# 1 thru # 8):
# 1 Administrator Rights
You must be logged into an account that has Administrator rights for
the machine. The account must have a password.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-4
UNIVERGE OW5000 Platform
# 2 IIS and ASP.NET
Ensure Microsoft Internet Information Services (IIS) 6.0 or later and
ASP.NET have been installed. This can be done using the following
steps:
Microsoft Windows Server 2003 (or 2003 R2)
Step 1
From the Start menu, select Control Panel > Add or Remove
Programs > Add/Remove Windows Components > Application
Server.
Step 2
Click the check box next to Application Server to select and then click the
Details button.
Step 3
Confirm that ASP.NET and Internet Information Services (IIS) are
checked properly.
Step 4
Click OK.
Step 5
Click Next. The IIS/ASP.NET installation will start.
Step 6
When the install is complete, click Finish.
Microsoft Windows Server 2008
Step 1
From the Start menu, select Control Panel > Administrative Tools >
Server Manager.
Step 2
Click Add Roles and check Web Server (IIS) in the Select Server Roles
page and then click Install. Web Server (IIS) displays in the Roles list.
Microsoft Windows Server 2008 R2
Step 1
From the Start menu, select Control Panel > Administrative Tools >
Server Manager.
Step 2
Click Add Role. The Add Role Wizard starts.
Step 3
Click Next and check Web Server (IIS).
Step 4
Click Next on this page and Next again on the following page. A Select
Role Service dialog box displays.
Step 5
Select ASP.NET. A required services page displays.
Step 6
Click Add required services.
Step 7
.NET Extensibility, ISAPI Extension, and ISAPI Filter will be checked.
Click Next and then click Install.
Step 8
When the installation is complete, click Finish.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-5
# 3 .NET Framework 3.5 SP1
Step 1
Place the UCE 2010 Disk 1 DVD into the DVD-ROM drive.
Step 2
From the Prerequisites menu, select the .NET Framework 3.5 SP1 link
to launch the installer.
Step 3
Click OK.
Step 4
Select Agree on the License Agreement page and then click Install.
Microsoft Windows Server 2008 R2
Step 1
From the Start menu, select Control Panel > Administrative Tools >
Server Manager.
Step 2
Click Add Role. The Add Role Wizard starts.
Step 3
Click Next and check Application Server. Click Next on this page and
Next again on the following page. A Select Role Service dialog box will
display.
Step 4
Confirm .NET Framework 3.5.1 is checked.
Step 5
Click Next and then click Install.
Step 6
When the installation is complete, click Finish.
# 4 Windows PowerShell (1.0)
Microsoft Windows Server 2003 (or 2003 R2)
Step 1
Place the UCE 2010 Disk 1 DVD into the DVD-ROM drive.
Step 2
From the Prerequisites menu, select a link to launch the installer for
either the 32-bit or 64-bit version of PowerShell 1.0, as required by your
hardware.
Step 3
Click OK.
Step 4
Select Agree on the License Agreement page and then click Install.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-6
UNIVERGE OW5000 Platform
Microsoft Windows Server 2008
Step 1
From the Start menu, select Control Panel > Administrative Tools >
Server Manager.
Step 2
Click Add Features and check Windows PowerShell in the Select
Features page and then click Install. Windows PowerShell displays in
the Features list.
# 5 Microsoft Windows Installer 4.5 (Microsoft Windows Server 2003
only)
Step 1
Place the UCE 2010 Disk 1 DVD into the DVD-ROM drive.
Step 2
From the Prerequisites menu, select the link to launch the installer for
either the 32-bit or 64-bit version of Windows Installer 4.5 for Windows
Server 2003, as required by your hardware.
Step 3
Click OK.
Step 4
Select Agree on the License Agreement page and then click Install.
# 6 Microsoft SQL Server 2005/2008
Microsoft SQL Server 2005/2008 must be installed and configured
before installing the OW5000 Platform. 
Refer to “Microsoft SQL Server 2008 Express Edition with Advanced Services” on
page B-1.
IMPORTANT
# 7 Install WCF Activation
Step 1
From the Start menu, select Administrative Tools > Server Manager.
Step 2
Click Add Features, expand .NET Framework 3.0 Features and check
WCF Activation in the Select Features page and then click Install.
Only Microsoft Windows Server 2008 requires this installation.
NOTE
Step 3
When the installation is complete, click Close.
# 8 Windows Update
Step 1
Execute a Windows Update after the installation to keep the environment
up to date.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-7
Installing the OW5000 Platform
Use the following steps to install the OW5000 Platform software.
Step 1
Place the UCE 2010 DVD into the computer's DVD-ROM drive. On most
computers Autorun automatically starts the installation when you load the
DVD. If Autorun is not enabled on the computer, you must do the
following:
—After placing the UCE DVD into the computer’s DVD-ROM drive, open
Windows Explorer and double-click the DVD-ROM drive icon.
—In the DVD-ROM file list, double-click the Autorun.exe file.
Step 2
From the OW5000 Platform menu, select a link to launch the installer for
the OW5000 Application Platform.
Step 3
If Microsoft Windows Installer 4.5, a pre-requisite for OW5000 Platform,
has not yet been installed, it will be installed automatically at this time. If
applicable, when the installation of Windows Installer 4.5 completes, an
OW5000 Platform message is displayed.
Figure 2-1 Microsoft Windows Installer 4.5 Prompt
Step 4
Click Yes to reboot the machine, then restart the OW5000 Platform
installation.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-8
UNIVERGE OW5000 Platform
Figure 2-2 OW5000 Platform Installer dialog box
Step 5
Click Yes and then click Next. A Welcome dialog box displays 
(Figure 2-3).
Figure 2-3 Welcome Dialog box
Step 6
Click Next. A Software License Agreement dialog box displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-9
Figure 2-4 Software License Agreement dialog box
Step 7
Read the software license agreement in the list box and click I accept
the terms in the license agreement and then click Next. A Customer
Information dialog box displays (Figure 2-5).
Figure 2-5 Customer Information dialog box
Step 8
Enter your User Name and Organization name in the text box fields and
click Next. A Sales Region Selection dialog box displays (Figure 2-6).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-10
UNIVERGE OW5000 Platform
Figure 2-6 Sales Region Selection dialog box
Step 9
Select the proper sales region from the drop-down list. Possible region
choices are listed in Table 2-3.
Table 2-3 Sales Regions
Japan
United States
Europe
Australia
Asia (Other)
Selectable PBX Type
UNIVERGE
UNIVERGE SV7000 SV7000
UNIVERGE
SV7000
UNIVERGE SV7000 UNIVERGE
TypeSS
SV7000 MPS
UNIVERGE
APEX7600i
UNIVERGE
NEAX2400 IPX
UNIVERGE
APEX3600i
UNIVERGE
NEAX2000 IPS
UNIVERGE
NEAX2000 IPS
UNIVERGE
SV7000
UNIVERGE
SV7000
UNIVERGE
SV7000 MPS
UNIVERGE
SV7000 MPS
UNIVERGE
NEAX2400 IPX
UNIVERGE
NEAX2400 IPX
UNIVERGE
NEAX2000 IPS
UNIVERGE
NEAX2000 IPS
NEAX 2400 IMS Internal
UNIVERGE SV8300 UNIVERGE SV8300 UNIVERGE SV8300 UNIVERGE SV8300 UNIVERGE SV8300
UNIVERGE SV8500 UNIVERGE SV8500 UNIVERGE SV8500 UNIVERGE SV8500 UNIVERGE SV8500
The above table is for the administrator. It is not used during installation.
NOTE
Step 10 Click Next. An Installation Destination Folder dialog box displays 
(Figure 2-7).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
Figure 2-7 Installation Destination Folder dialog box
Step 11
Do one of the following:
—To install to the default folder, click Next.
—To select a different location, click Change. A Change Current
Destination Location dialog box displays (Figure 2-8).
Figure 2-8 Change Current Destination Location dialog box
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-11
2-12
UNIVERGE OW5000 Platform
Step 12 Do one of the following:
—select the desired folder from the drop-down list.
—create a new folder by clicking the new folder icon
different location.
to save to a
Step 13 Click OK. A User Name / Password dialog box displays (Figure 2-9).
Figure 2-9 User Name / Password dialog box
Step 14 Enter the User name. 

The User ID format is domain\User ID or UserID if the account is on the
local machine. This User ID must have administrator rights on the target
machine.
Step 15 Enter the Password. The password is used to run under the User ID
account of the related service. The Password field cannot be blank.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-13
Selecting an SQL Server from an Existing Database
Step 1
To select an SQL server from an existing database, click Next from the
“User Name / Password dialog box” on page 2-12. A Database Server
dialog box displays (Figure 2-10).
Figure 2-10 Database Server dialog box
Step 2
Specify the Database Server (<hostname>\<instance name>) where the
SQL database resides. By default, this will display the hostname of the
local machine (where you are installing OW5000), but if the SQL
database resides on a different machine, you must Browse to the correct
instance.
Step 3
Select Server authentication…. and then enter the password assigned
at the “Database Engine Configuration dialog box” on page B-10.
Step 4
Accept the default value of OW5000 for the Name of database catalog
field.
Step 5
Click Next. An Installing OW5000 Platform dialog box displays 
(Figure 2-11).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-14
UNIVERGE OW5000 Platform
Figure 2-11 Installing OW5000 Platform dialog box
Step 6
Click Install. An installing dialog box displays briefly and then an
Installation Complete dialog box displays (Figure 2-12).
Figure 2-12 Installation Complete dialog box
Step 7
Select Finish to complete the installation.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
Step 8
2-15
Register the license in OW5000. Refer to the OW5000 Platform License
Activation section for details.
OW5000 Platform works 30 days after installation without any license activation. The
Expired date is displayed in OW5000 Administrator.
NOTE
OW5000 Platform License Activation
There are two software license activation systems:
—US, Australia, Europe
License Manager Client
—Asia, Russian
Software License Activation Center
The following topics are included in this section.
• US, Australia, and European Market
• Asian and Russian Markets
US, Australia, and European Market
Follow the steps below to activate the OW5000 Platform.
To get the valid serial number and activation key, please access the
Software.
Activation Flow
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-16
UNIVERGE OW5000 Platform
Installing License Manager
Refer to the License Manager Client Operations Guide for details on the
installation and configuration steps. Documentation is on the LMC DVD.
NOTE
License Manager is used for the PBX and other applications. If the system has
already installed the License Manager, an extra License Manager is not required;
OW5000 can also use it.
Configuring License Manager Information in OW5000 Administrator
Follow the steps below to configure the License Manager information
into the OW5000 Administrator.
Step 1
Open OW5000 Administrator from Start > All Programs > NEC
OW5000 > Runtime Platform > OW5000 Administrator and then login
to the system.
Step 2
Click OW5000 > Settings to set the License Manager server IP Address/
Name and port number in the LICENSE MANAGER CONNECTION
INFORMATION field. 49300 is treated as the default port number.
Figure 2-13 License Manager Settings
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-17
Confirming the Installed License
Follow the steps below to confirm the installed license.
Step 1
Open OW5000 Administrator from Start > All Programs > NEC
OW5000 > Runtime Platform > OW5000 Administrator and then login
to the system.
Step 2
Click OW5000 > Platform > Licenses > Licensed Information tab to
confirm the down-loaded license information.
Figure 2-14 Licensed Information (Confirmation)
Asian and Russian Market
Follow the steps below to activate the OW5000 Platform.
Activation Flow
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-18
UNIVERGE OW5000 Platform
Creating a Hardware Key Code File
Follow the steps below to create a Hardware Key Code File.
Step 1
Place the OW5000 DVD into the computer's DVD-ROM drive while
holding down the Shift key.
Step 2
Run HardWareKeyGenerator.exe from the Start menu
(DVD-ROM drive)\ LicenseTool\HardWareKeyGenerator.exe
Step 3
Click OK. Figure 2-15 displays.
Figure 2-15 Hardware Key Code Generator
Step 4
If a different destination path is used, click Browse and select the proper
folder to be exported.
Step 5
Click Execute. Figure 2-16 displays.
Figure 2-16 Confirming the File Path dialog box
Step 6
Click OK. An OW5000 HARDWARE KEY CODE(A).cod is created in the
folder.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-19
Figure 2-17 Hardware Key Code Confirmation dialog box
Step 7
Click OK and then click Exit.
Registering to the Software License Activation Center
Step 1
Login to the Software License Activation Center:
http://www.bcom.nec.co.jp/sla/English
Step 2
Register the Hardware Key Code file, which was created in the previous
section, and the Software Key Code file CD, and then get the Activation
Code file. The Activation Code file is attached in the email sent from the
Software License Activation Center.

File Format: SerialNums_XXXXXXXXXXXXX.xml
(XXXXXXXXXXXXX is Hardware Key Code)

For more information about activation, please see the manual on the web
site.
License Management
Follow the steps below to start up the License Activator. This can be
done before or after the OW5000 Platform installation.
Before OW5000 Platform Installation
Step 1
Place the OW5000 DVD into the computer's DVD-ROM drive while
holding down the Shift key.
Step 2
Run LicenseInstaller.exe from the Start menu:
(DVD-ROM drive)\ LicenseTool\LicenseInstaller.exe
Step 3
Click OK to display Figure 2-18.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-20
UNIVERGE OW5000 Platform
After OW5000 Platform Installation
Step 1
From the Start menu, select NEC OW5000 > Runtime Platform >
License Installer. Figure 2-18 displays.
Figure 2-18 UNIVERGE OW5000 License Activator dialog box
License Install
Follow the steps below to install the license.
Step 1
Run the License Installer. The pre-registered Hardware Key code and
License information displays in the UNIVERGE OW5000 License
Activator.
LDAP license is installed as the default status, so do not delete the license. If the
license is accidentally removed, restart the License Installer.
NOTE
NOTE
The Hardware Key Code is generated based on the OW5000 server hardware
information. Therefore, once the OW5000 server hardware is replaced, confirm that
the Hardware Key Code is using License Installer. If a different Hardware Key Code
is displayed, re-registration is required for the Software License Activation Center.
The Previous Hardware Key Code is described in the email from the Software
License Activation Center.
Step 2
Click Add New License. An Add New License dialog box displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
Step 3
2-21
To input the Serial Number and Activation Key manually, follow the steps
below. To install from the Activation Code, go to Installing from the
Activation Code File.
Input Serial Number and Activation Key Manually
Step 1
Check the Input Serial Number and Activation Key manually radio
button.
The Serial Number and Activation Key are described in the email sent from the
Software License Activation Center.
NOTE
Step 2
Select License Type from the drop-down menu.
Step 3
Enter the Serial Number and Activation Key.
Step 4
Click OK. A License(s) installed successfully message displays.
Step 5
Click OK. The installed license information is displayed in the
UNIVERGE OW5000 License Activator main dialog.
Step 6
Click X to close the License Installer.
Installing from the Activation Code File
Step 1
Check Input from the XML radio button.
The Activation Code file is described in the email sent from the Software License
Activation Center.
NOTE
Step 2
Click the Browse button, select the Activation Code file, and then click
Open. The file name displays in the Import File field.
Step 3
Click OK. A License(s) installed successfully message displays.
Step 4
Click OK. The installed license information is displayed in the
UNIVERGE OW5000 License Activator main dialog box (Figure 2-19).
Step 5
Click X to close the License Installer.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-22
UNIVERGE OW5000 Platform
Figure 2-19 License Activator—Main dialog box
Confirming the Installed License
Follow the steps below to confirm the installed license.
Step 1
Run License Installer. Figure 2-19 displays listing the Hardware Key
Code and installed License information.
Step 2
Click the License Type heading to sort the information.
Step 3
After selecting the target license, click the Delete Selected License
button to delete the installed license.
Step 4
Click X to close the License installation.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-23
Hardware Replacement Process (Asian and Russian Markets only)
When the OW5000 server is replace, the Hardware Key Code may
change.
If the Hardware Key Code is changed, follow the steps below to reregister the license.
NOTE
If a different Hardware Key Code displays, re-registration is required for the Software
License Activation Center. The previous Hardware Key Code is described in an
email from the Software License Activation Center.
Re-registration Flow
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-24
UNIVERGE OW5000 Platform
Uninstalling the OW5000 Platform
In Windows Server 2003 (or 2003 R2), the OW5000 Platform can be
uninstalled using the Windows operating system Add/Remove
software function in the Windows Control Panel. In Windows Server
2008, the OW5000 Platform can be uninstalled using the Programs
and Features function in Windows Control Panel.
• all the files / folders created by the install will be removed
• the services will be removed
• the registry keys will be removed
• the database will be dropped
Step 1
From the Start menu, select Control Panel > Administrative Tools >
Services, and stop the OWWatch Dog, OW OAIMonitor, and the Remote
Call Control. Then check all the OW5000 services stopped in this
sequence:
OWWatch Dog
OW OAIMonitor
OWAccessServer (if installed)
Remote Call Control (if installed)
To stop a service, right-click the Service name and click Stop in the
popup menu.
The Access Server and Remote Call Control must be uninstalled before uninstalling
the OW5000 Platform.
NOTE
Step 2
In the Add/Remove dialog of Windows Server 2003 (or in the Program
and Features dialog of Windows Server 2008), select OW5000 Platform
and then click Remove in Windows Server 2003 (or click Uninstall/
Change in Windows Server 2008). A Confirm Component Removal
dialog box displays 
(Figure 2-20).
Figure 2-20 Confirm Component Removal dialog box
Step 3
Click Yes to remove OW5000 Platform. 

To uninstall Microsoft SQL Server 2008 from the server, please refer to
“Microsoft SQL 2008 Express Edition Uninstall” on page B-16 for
uninstall steps.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-25
Step 4
Remove Microsoft Report Viewer, Microsoft SQL Server Native
Client. and Microsoft SQL Server Compact 3.5 SP1 English from the
Add or Remove Programs option from the Control panel.
Step 5
Delete the file: 
Microsoft SQL Server 2008 Express Edition:
C:\Program Files\Microsoft SQL
Server\MSSQL10.SQLEXPRESS\MSSQL\DATA\*

Microsoft SQL Server 2005 Express Edition:
C:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Data\*
(delete the folder also)
Step 6
From the desktop, click the Start button and then select Control Panel>
Administrative Tools > Internet Information Services (IIS) Manager.
Step 7
Delete the following sites from Web Sites > Default Web Site if they are
still there.

OW5000
OW5000WS
owxdata
CYGNUS
PS1000
InfoAPIServices
VCMWebService
Step 8
Reboot the system. OW5000 is now removed from your computer.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-26
UNIVERGE OW5000 Platform
Upgrading the OW5000 Platform from R2/R3
To upgrade the OW5000 from R2 to R3, the following sequences are
required:
Before starting the OW5000 Platform upgrade to R4, uninstall Remote
Call Control Service and OWAccessServer if they are installed.
IMPORTANT
If you are upgrading from OW5000 Release 2 to OW5000 Release 4, after the
upgrade process has completed, you must manually edit the PhoneType parameter.
• Dterm -> Dterm or SP30(SIP)
• SingleLine -> Analog or PS or VoWLAN
IMPORTANT
If you are upgrading from OW5000 Release 2 to OW5000 R4, after the upgrade
process has completed, you must manually change the PBX Management Locations
parameter. If 0 is assigned in the National Code field, remove 0 and set blank (no
input).
When you upgrade OW5000 from R2/R3 to R4 or later, the translation rule data must
be reassigned from AniTranslate.txt to the database thorough OW5000 Administrator
RCC configuration page.
IMPORTANT
Before upgrading, backup the registry and OW5000 database to be able to rollback.
Refer to “Current Version Backup” on page A-1 for details.
IMPORTANT
IMPORTANT
For US, Australia and Europe only: Before starting the OW5000 Platform upgrade to
R4, it is recommended that you configure a License Manager Client and confirm that
the appropriate licenses are available for the OW5000 Platform and associated
applications. The 90-Day trial license available with fresh installation of OW5000 R4
is not available when upgrading from a prior release. The OAI Server service will not
start following upgrade until the License Manager Client has been configured to
provide licenses to OW5000 Platform. (This can be done after performing the
OW5000 Platform upgrade, but it's more expedient to configure the LMC in advance
of upgrading the OW5000 Server.)
Please refer to the License Manager Client Operations Guide for more information.
• Stopping a Service
• Upgrading the Platform from an older Version
• Installing License Manager Client (US, Australia and Europe only)
• Installing the New Software Licenses (US, Australia, and Europe only)
• OW5000 Platform License Activation (Asian and Russian Market)
Stopping a Service
Step 1
Click the Start button on the desktop, and then select Control Panel >
Administrative Tool > Services to stop the OWWatch Dog and OW
OAIMonitor after changing the Startup type from Automatic to Manual.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-27
Upgrading the Platform from an older Version
Step 1
Place the UCE 2010 Disk 3 DVD into the computer's DVD-ROM drive.
Step 2
Navigate to and select the OW5000 Application Platform link to launch
the OW5000 Platform installer.
If Figure 2-32, “Logon Information dialog box” displays, please follow the steps
beginning with Step 15 on page 2-31.
NOTE
Figure 2-21 Remove OW5000 Platform dialog box
Step 3
Click Remove Platform and All Components. 

If Watch Dog was not previously stopped, the following error message
displays (Figure 2-22).
Figure 2-22 Watch Dog Error Message
Step 4
Stop Watch Dog and click OK.
Step 5
If OAIMonitor was not previously stopped, the following error message
displays (Figure 2-23).
Figure 2-23 OAIMonitor Error Message
Step 6
Stop OAIMonitor and click OK. A Confirm Component Removal dialog
box displays (Figure 2-24).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-28
UNIVERGE OW5000 Platform
Figure 2-24 Confirm Component Removal dialog box
Step 7
Click Yes. A Removing Programs dialog box displays for each
component removed (Figure 2-25).
Figure 2-25 Removing Programs dialog box
Step 8
Click OK after each dialog box displays. A Remove Shared File dialog
box displays (Figure 2-26).
Figure 2-26 Remove Shared File dialog box
Step 9
Click Yes To All. A Remove Shared File Confirmation dialog box
displays (Figure 2-27).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-29
Figure 2-27 Remove Shared File Confirmation dialog box
Step 10 Click Yes. An OW5000 Platform Removal Confirmation dialog box
displays (Figure 2-28).
Figure 2-28 OW5000 Platform Removal Confirmation dialog box
WARNING
Please do not restart your machine as recommended by this message. The
message should be ignored after clicking OK to close it. This message is always
displayed whenever an OW5000 Platform uninstall has completed, but in this
context, please allow the upgrade install to continue by not restarting the machine.
Step 11
Click OK. A Check Database for Upgrading dialog box displays 
(Figure 2-29).
Click OK after each dialog box until there are no more applications to remove. Click
Close in the Remove OW5000 Platform Components dialog box (Figure 2-21).
NOTE
Figure 2-29 Check Database for Upgrading dialog box
Step 12 Click Next to display Figure 2-30.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-30
UNIVERGE OW5000 Platform
Figure 2-30 OW5000 Database Utility dialog box
Step 13 Select SQL Authentication and supply the sa password for the
OW5000 database. Note: If the SQL database resides on the same
machine from which OW5000 is being uninstalled, SQL may have been
installed using Windows Authentication. Otherwise, you must use SQL
Authentication to establish a connection. Click Execute. Figure 2-31
displays.
Figure 2-31 Database Upgrading dialog box
Step 14 Click Close to exit. A Logon Information dialog box displays 
(Figure 2-32).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-31
Figure 2-32 Logon Information dialog box
Step 15 Enter an Administrator account's User name and Password and then
click Next to display Figure 2-33.
Figure 2-33 Ready to Upgrade the Program dialog box
Step 16 Click Upgrade. Figure 2-34 displays briefly and then an Install
Completed dialog box displays Figure 2-35.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-32
UNIVERGE OW5000 Platform
Figure 2-34 Upgrading OW5000 Platform dialog box
Figure 2-35 Install Completed dialog box
Step 17 Click Finish to complete the installation. If you are prompted to reboot,
please restart the machine.
NOTE
After the upgrade, the WatchDog Helper configuration is initialized. If only the
SIMPLE (Presence) feature is used and OAI configuration is not required, remove
OWOaiServer, OWTelephony Event Notification, and OWConference Server service
from WatchDog Helper.
Confirming the Current Platform Version
From the OW5000 Administrator Version Information page, a user can
confirm the current platform version.
Step 1
From the Start Menu, select NEC OW5000 > Runtime Platform >
OW5000 Administrator and then open the OW5000 > Version
Information page after logging in.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-33
If the Version of SUMMARY BUILD INFORMATION is higher that 6.5.0,
the upgrade was done properly.
If you need to rollback from an installed R4 to R3, refer to “Rollback Procedures” on
page A-4 for more information.
NOTE
Installing License Manager Client (US, Australia and Europe only)
If License Manager Client is not installed in the system, refer to the
License Manager Client Operations Guide to install and configure the
program before moving on to the next process.
If you install License Manager Client and OW5000 platform on the same server, a
different instance name must be assigned.
IMPORTANT
Installing the New Software Licenses (US, Australia, and Europe
only)
To install the new software license, select Settings from the OW5000
Administrator. A Settings dialog box displays (Figure 2-36).
Figure 2-36 Settings dialog box
Step 1
Enter the IP Address/Name in the LICENSE MANAGER CONNECTION
INFORMATION field. 

UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-34
UNIVERGE OW5000 Platform
For all other processes and configuration, please refer to the MA4000
License Manager Operation Guide.
OW5000 Platform License Activation (Asian and Russian Market)
Follow the steps below to activate the OW5000 Platform:
Figure 2-37 Activation Flow
Create a Hardware Key Code File
Use the steps below to create a Hardware Key Code File.
Step 1
Place the OW5000 DVD into the DVD-ROM drive while holding down the
Shift key.
Step 2
Run HardWareKeyGenerator.exe from the Start menu. (DVD-ROM
drive)\ LicenseTool\HardWareKeyGenerator.exe
Step 3
Click OK.
Figure 2-38 Hardware Key Code Generator
Step 4
If a different destination path is used, click Browse and select the proper
folder to be exported.
Step 5
Click Execute. Figure 2-39 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-35
Figure 2-39 Hardware Keycode Confirmation dialog box
Step 6
Click OK. The OW5000 HARDWARE KEY CODE(A).cod is created in
the folder. Figure 2-40 displays.
Figure 2-40 Hardware Key Code Created dialog box
Step 7
Click OK and then click Exit to exit the tool.
Registering to the Software License Activation Center
Step 1
Login to the Software License Activation Center at http://
www.bcom.nec.co.jp/sla/English
Step 2
Register the Hardware Key Code file (created in the previous section)
and the Software Key Code file CD. You will then get an Activation Code
file. The Activation Code file is attached in the email sent from the
Software License Activation Center.

File Format: SerialNums_XXXXXXXXXXXXX.xml
(XXXXXXXXXXXXX is Hardware Key Code)
For more information regarding activation, please refer to the manual
on the web site.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-36
UNIVERGE OW5000 Platform
Uninstalling the R3 License
Follow the steps below to start the License Activator.
Step 1
From the Start menu, select NEC OW5000 > Runtime Platform >
License Installer. Figure 2-41 displays.
Figure 2-41 UNIVERGE OW5000 License Activator dialog box
Step 2
Select all the licenses except the LDAP license and click Delete
Selected License. Figure 2-42 displays.
Figure 2-42 OW5000 License Activator dialog box
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-37
Installing R4 License
Step 1
Click Add New License (Figure 2-42).
Step 2
Check the Input from XML radio button.
The Activation Code file is attached in the email sent from the Software License
Activation Center.
NOTE
Step 3
Click the Browse button and select the Activation Code file.
Step 4
Click Open. The file name displays in the Import File field.
Step 5
Click OK. A License(s) installed successfully message displays.
Step 6
Click OK. The installed license information is displayed in the
UNIVERGE OW5000 License Activator main dialog box.
Step 7
Click X to close the License Installer.
Upgrading the OW5000 Platform from an Older Version of R4
To upgrade the OW5000 from an older version of R4 to the latest R4, the
following sequences are required.
Backup the OW5000 database before proceeding. Refer to the Database Backup/
Restore section in the OW5000 Configuration Guide.
IMPORTANT
• Stopping a Service
• Upgrading the OW5000 Platform
• Configuring the Current Platform Version (US, Australia and Europe
Markets)
Stopping a Service
Step 1
Click the Start button on the desktop, and then select Control Panel >
Administrative Tool > Services to stop the following OW5000 services
in the following order:

OWWatch Dog
OW OAI Monitor
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-38
UNIVERGE OW5000 Platform
Upgrading the OW5000 Platform
Step 1
Place the newest UCE 2010 Disk 3 DVD into the computer's DVD-ROM
drive.
Step 2
Navigate to and select the OW5000 Application Platform link to launch
the OW5000 Platform installer.
Step 3
Click Yes. Figure 2-47 displays.
Depending on the Platform version you are upgrading, Figure 2-47 may not display.
NOTE
An OW5000 Database Utility dialog box displays (Figure 2-43).
Figure 2-43 OW5000 Database Utility dialog box
Step 4
Select SQL Authentication and supply the sa password for the
OW5000 database. Note: If the SQL database resides on the same
machine from which OW5000 is being uninstalled, SQL may have been
installed using Windows Authentication. Otherwise, you must use SQL
Authentication to establish a connection. Click Execute. An OW5000
Database Utility—Processing dialog box displays.
Depending on the Platform version you are upgrading, an OW5000 Database
Utility—Processing dialog box may not display.
NOTE
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
Step 5
2-39
Click Close. Figure 2-44 displays.
Figure 2-44 Logon Information dialog box
Step 6
Please enter an Administrator account's User name and then click Next.

This account will be used as the login account of the related services.
The format of the User ID must be domain\User ID or User ID of the local
server. This account must have Administrator rights.
Figure 2-45 OW5000 Platform Upgrade
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-40
UNIVERGE OW5000 Platform
Step 7
Click Next. Figure 2-46 displays briefly and then a Setup Complete
dialog box displays (Figure 2-47).
Figure 2-46 Upgrading in Progress dialog box
Once the database upgrade starts, do not click the Cancel button.
NOTE
Figure 2-47 Setup Complete dialog box
Step 8
NOTE
Click Finish. If you are prompted to reboot, please restart.
After the upgrade, the WatchDog Helper configuration is initialized. If only the
SIMPLE (Presence) feature is used and OAI configuration is not required, remove
OWOaiServer, OWTelephony Event Notification, and OWConference Server service
from WatchDog Helper.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
UNIVERGE OW5000 Platform
2-41
Configuring the Current Platform Version (US, Australia and Europe
Markets)
From the OW5000 Administrator Version Information page, a user can
confirm the current platform version.
Step 1
From the Start Menu, select NEC OW5000 > Runtime Platform >
OW5000 Administrator and then open the OW5000 > Version
Information page after logging in.

If the Version of SUMMARY BUILD INFORMATION indicates the current
platform version, the upgrade was done properly.
Asian and Russian Markets
A user can confirm the upgrade as follows:
Step 1
Open Issue.txt under C:\Program Files\NEC\OW5000\Runtime
Platform\Issue.txt (in case of default path).
Step 2
Confirm the following underlined number as the version number. If there
are multiple versions, check the bottom version.

DO NOT MODIFY THIS FILE 
SC-3904 OWX PROG-R4 ISSUE X.XX
UCE Application Platform (UNIVERGE OW5000) Installation Guide
2-42
UNIVERGE OW5000 Platform
UCE Application Platform (UNIVERGE OW5000) Installation Guide
3-1
3
OW5000 Remote Call Control Service
Remote Call Control (RCC) Service is a program that is needed to
provide a SIP based CSTA interface. This program enables NEC's PBXs
to collaborate with CSTA-based 3rd party applications, such as
Microsoft’s Office Communications Server 2007.
This document specifies the steps needed to install the RCC Service for
the Office Communication Server (OCS).
For more information, refer to the UNIVERGE OW5000 Remote Call
Control Configuration Guide.
The following topics are included in this chapter:
Chapter Topics
• Installing the OW5000 Remote Call Control Service
Installing the OW5000 Remote Call Control Service
Use the following steps to install the Remote Call Control software. RCC
can be installed on the same server as the OW5000 platform. Only one
RCC is available per system.
Do not install Remote Call Control unless LCS/OCS collaboration is used.
IMPORTANT
Remote Call Control service does not support an upgrade install. Before upgrading,
uninstall the current version and then reboot the server.
IMPORTANT
When you upgrade OW5000 from R2/R3 to R4 or later, the translation rule data must
be reassigned from AniTranslate.txt to the database thorough the OW5000
Administrator Remote Call Control configuration page.
IMPORTANT
Step 1
Place the UCE 2010 DVD into the computer's DVD-ROM drive. On most
computers Autorun automatically starts the installation when you load the
DVD. If Autorun is not enabled on the computer, you must do the
following:
—After placing the UCE DVD into the computer’s DVD-ROM drive, open
Windows Explorer and double-click the DVD-ROM drive icon.
—In the DVD-ROM file list, double-click the Autorun.exe file.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
3-2
OW5000 Remote Call Control Service
Step 2
From the UCE Application Platform Menu, select the Remote Call
Control link to start the OW5000 Remote Call Control installation
program. A Warning dialog box displays (Figure 3-1).
Figure 3-1 Warning dialog box
Step 3
Click Yes to continue with the installation. A Remote Call Control—
Welcome dialog box displays (Figure 3-2).
Figure 3-2 Remote Call Control—Welcome dialog box
Step 4
Click Next. A License Agreement dialog box displays (Figure 3-3).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
OW5000 Remote Call Control Service
3-3
Figure 3-3 License Agreement dialog box
Step 5
Read the license agreement and click I accept the terms in the license
agreement to accept the terms of the agreement.
Step 6
Click Next. A Ready to Install dialog box displays (Figure 3-4).
Figure 3-4 Ready to Install dialog box
Step 7
Click Install. An Installing Remote Call Control dialog box displays
(Figure 3-5).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
3-4
OW5000 Remote Call Control Service
Figure 3-5 Installing Remote Call Control dialog box
Step 8
After all files are copied, click Next. An Installation Complete dialog box
displays (Figure 3-6).
Figure 3-6 Installation Complete dialog box
Step 9
Click Finish to complete the installation of Remote Call Control—
OW5000. Figure 3-7 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
OW5000 Remote Call Control Service
Figure 3-7 Patch Installation Wizard dialog box
Step 10 Click Update. Figure 3-8 displays.
Figure 3-8 Remote Call Control—Patch Complete dialog box
Step 11
NOTE
NOTE
Click Finish to complete the patch install.
To remove or repair the Remote Call Control service, open the Control Panel, select
Add or Remove Programs, select Remote Call Control—OW5000, and then click
Remove.
In the SV8500/SV7000/IPX system, a Reserved Number, which is assigned as an
OW5000 API, is required for each PBX to use Remote Call Control service. For more
information, refer to the UNIVERGE OW5000 Configuration Guide.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
3-5
3-6
OW5000 Remote Call Control Service
NOTE
NOTE
NOTE
NOTE
A Remote Call Control listen port must be assigned to use the Remote Call Control
service. After configuration of the listen port, restart the Remote Call Control service
from Start > Administrative Tools > Services. For more information, refer to the
UNIVERGE OW5000 Configuration Guide.
To enable Remote Call Control service, it is required that you update the PBX license
information. Open OW5000 Administrator > License Manager then click the
Enable PBXs tab. Confirm the target PBX's license is set and then click Apply. See
the OW5000 Configuration Guide for more details.
Remote Call Control Service is not listed when you install the OW5000 platform. So,
it is required that you add the Remote Call Control Service manually. Refer to the
WatchDog Helper section of the UNIVERGE OW5000 Configuration Guide for more
details.
Remote Call Control Service is not registered in WatchDog Helper. Add Remote Call
Control Service to monitor the service from WatchDog.
Please refer to the UNIVERGE OW5000 Configuration Guide for more details.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
4-1
4
OW5000 Access Server
Access Server is a program that is needed to provide SIP/SIMPLE
interface to the NEC device and to 3rd party applications.
This document specifies the steps needed to install the Access Server.
For configuration information, please refer to the OW5000 Configuration
Guide.
Installing OW5000 Access Server
If Access Server is installed on a different server than the OW5000 Platform server,
you must install Microsoft .NET Framework 3.5 SP1 beforehand.
IMPORTANT
NOTE
Upgrade install is not supported for OW500 Access Server. When upgrade is
required, please uninstall OW5000 Access Server, restart the Operation System,
then install the latest software.
Use the following steps to install the Access Server software.
Step 1
Place the UCE 2010 DVD into the computer's DVD-ROM drive. On most
computers Autorun automatically starts the installation when you load the
DVD. If Autorun is not enabled on the computer, you must do the
following:
—After placing the UCE DVD into the computer’s DVD-ROM drive, open
Windows Explorer and double-click the DVD-ROM drive icon.
—In the DVD-ROM file list, double-click the Autorun.exe file. .
Access Server supports both 32bit(x86) environment and 64bit(x64) environment.
Please select the appropriate installer based on the server which you use to install.
NOTE
Step 2
From the UCE Application Platform Menu, select the OW5000 Access
Server (32bit) or Access Server (64bit) link to start the OW5000 Access
Server installation program. An Access Server—Welcome dialog box
displays (Figure 4-1).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
4-2
OW5000 Access Server
Figure 4-1 Access Server—Welcome dialog box
Step 3
Click Next. A License Agreement dialog box displays (Figure 4-2).
Figure 4-2 License Agreement dialog box
Step 4
Read the license agreement and click I accept the terms in the license
agreement to accept the terms and then click Next. A Destination Folder
dialog box displays (Figure 4-3).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
OW5000 Access Server
4-3
Figure 4-3 Destination Folder dialog box
Step 5
To select a folder other than the default location shown in the dialog box,
click Change and enter the new location. When finished, click Next to
continue. A Database Server dialog box displays (Figure 4-4).
Figure 4-4 Database Server dialog box
Step 6
Enter the database instance name using one of the following methods:
—Enter directly in the text box.
— Select from the drop-down list.
— Click the Browse button and select from the database server list.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
4-4
OW5000 Access Server
Step 7
Select Server authentication using the Login ID and password
below and then enter the sa login password. Refer to Figure B-12,
“Database Engine Configuration dialog box” for more details.
Step 8
Enter the Database name, which will be used by the OW5000 Access
Server, in the Name of database catalog field.
Do not change the default value OW5000.
IMPORTANT
Step 9
Click Next. A Server Information dialog box displays (Figure 4-5).
Figure 4-5 Server Information dialog box
If Access Server is installed on the same server as the OW5000 Platform, follow
Step 10 to Step 13 below.
NOTE
Step 10 Enter the Platform Server Name. This is the server name where the
OW5000 Platform is installed.
Step 11
Enter the Platform Server IP Address. This is the IP address where the
OW5000 Platform is installed.
Step 12 Enter the Platform Server Port. This is the listen port of the OW5000
Platform (default is 5690).
Step 13 Enter the Database Name. The instance name of the OW5000
database. If the database is named Instance, this field is
UCE Application Platform (UNIVERGE OW5000) Installation Guide
OW5000 Access Server
4-5
SERVERNAME\INSTANCENAME. If the database is default Instance,
this field is SERVERNAME.
NOTE
If you are using the SQL Server 2008 Express Edition bundled with the OW5000
Platform, "SQLEXPRESS" is assigned as the instance name. Type "(server name
where the OW5000 platform is installed)\SQLEXPRESS" as the Database Name.
Step 14 Click Next. A Ready to Install dialog box displays (Figure 4-6).
Figure 4-6 Ready to Install dialog box
Step 15 Click Install. An Installing Access Server dialog box displays 
(Figure 4-7).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
4-6
OW5000 Access Server
Figure 4-7 Installing Access Server dialog box
Step 16 After all files are copied, click Next. An Installation Complete dialog box
displays (Figure 4-8).
Figure 4-8 Installation Complete dialog box
UCE Application Platform (UNIVERGE OW5000) Installation Guide
OW5000 Access Server
4-7
Step 17 Click Finish to complete the installation of Access Server.
If Access Server is installed on a different server than the OW5000 Platform server,
the following configuration is required.
IMPORTANT
NOTE
NOTE
Double-click the Administrative Tools icon in the Control Panel. A Services
Window—AccessServer dialog box displays. Change the Recovery settings as
shown in (Figure 4-9).
OW5000 Access Server is not listed when you install the OW5000 platform. So, it is
required that you add OW5000 Access Server manually. Refer to the WatchDog
Helper section of the UNIVERGE OW5000 Configuration Guide for more details.
OW5000 Access Server Service is not registered in WatchDog Helper. Add OW5000
Access Server Service to monitor the service from WatchDog. Please refer to the
UNIVERGE OW5000 Configuration Guide for more details.
Figure 4-9 Services Window—AccessServer dialog box
When uninstall of OW5000 Access Server is required, please open Add or Remove
Programs, select OW5000 Access Server, and then click Remove.
NOTE
For information on configuring the Access Server, refer to the UNIVERGE
OW5000 Configuration Guide.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
4-8
OW5000 Access Server
UCE Application Platform (UNIVERGE OW5000) Installation Guide
5-1
5
Log Viewer
Log Viewer is a utility in the UNIVERGE OW5000. OW5000 applications
generally log events to the OW5000 Log Server (OAI Monitor), and
OW5000 Log Server. These logs are then stored into the log file.
Log Viewer gives a system administrator the ability to:
• Connect to the OW5000 Log Server application that is running and
view events logged by other applications.
• Open .LOG files generated by the Log Server to query, filter, and
display their contents.
• Open the log file, which is created by the OW5000 Log Server, and
display the Real-time log information.
LogViewer is installed automatically when the OW5000 Platform is
installed. You can also install LogViewer at another server/client
machine. This chapter explains the installation process of LogViewer
from the UCE 2010 Disk 3 DVD menu.
This document specifies the steps needed to install the Log Viewer. For
configuration information, please refer to the OW5000 Configuration
Guide.
NOTE
There is no need to perform an independent installation of Log Viewer on the same
machine where OW5000 Platform has been installed. Both Log Viewer and DBTool
are installed automatically when the Platform is installed.
Installing Log Viewer
Use the following steps to install the Log Viewer software.
Step 1
Place the UCE 2010 DVD into the computer's DVD-ROM drive. On most
computers Autorun automatically starts the installation when you load the
DVD. If Autorun is not enabled on the computer, you must do the
following:
—After placing the UCE DVD into the computer’s DVD-ROM drive, open
Windows Explorer and double-click the DVD-ROM drive icon.
—In the DVD-ROM file list, double-click the Autorun.exe file.
Step 2
From the UCE Application Platform Menu, select the Log Viewer link to
start the OW5000 LogViewer installation program. A Log Viewer—
Welcome dialog box displays (Figure 5-1).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
5-2
Log Viewer
Figure 5-1 Log Viewer—Welcome dialog box
Step 3
Click Next. A Destination Folder dialog box displays (Figure 5-2).
Figure 5-2 Destination Folder dialog box
Step 4
To select a folder other than the default location shown in the dialog box,
click Change and enter the new location. When finished, click Next to
continue. A Ready to Install dialog box displays (Figure 5-3).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Log Viewer
5-3
Figure 5-3 Ready to Install dialog box
Step 5
Click Install. An Installing Log Viewer dialog box displays briefly and
then an Installation Complete dialog box displays (Figure 5-4).
Figure 5-4 Installation Complete dialog box
Step 6
Click Finish to complete the installation of Log Viewer.
When uninstall of OW5000 Log Viewer is required, please open the Control Panel,
select Add or Remove Programs, select OW5000 LogViewer and then click Remove.
NOTE
Upgrade install is not supported for OW5000 Log Viewer. When version up is
required, please uninstall OW5000 Log Viewer, restart the Operation System, and
then install the latest software.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
5-4
Log Viewer
UCE Application Platform (UNIVERGE OW5000) Installation Guide
6-1
6
DB Tool
The DB Tool is a utility in the OW5000 Platform. It provides a system
administrator the capability to import/export data between the OW5000
databases and text files. This tool has the following functions:
• Database Import
• Database Export
• Bulk Delete
The DB Tool is installed automatically when the OW5000 Platform is
installed. You can also install the DB Tool at another server/client
machine. This chapter explains the installation process of the DB Tool
from the UCE 2010 Disk 3 DVD menu.
NOTE
There is no need to perform an independent installation of DB Tool on the same
machine where OW5000 Platform has been installed. Both Log Viewer and DB Tool
are installed automatically when the Platform is installed.
Installing DB Tool
Use the following steps to install the DB Tool software.
Step 1
Place the UCE 2010 DVD into the computer's DVD-ROM drive. On most
computers Autorun automatically starts the installation when you load the
DVD. If Autorun is not enabled on the computer, you must do the
following:
—After placing the UCE DVD into the computer’s DVD-ROM drive, open
Windows Explorer and double-click the DVD-ROM drive icon.
—In the DVD-ROM file list, double-click the Autorun.exe file.
Step 2
From the UCE Application Platform Menu, select the OW5000 DB Tool
link to start the DB Tool installation program. A DB Tool—Welcome dialog
box displays (Figure 6-1).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
6-2
DB Tool
Figure 6-1 DB Tool—Welcome dialog box
Step 3
Click Next. A Destination Folder dialog box displays (Figure 6-2).
Figure 6-2 Destination Folder dialog box
Step 4
To select a folder other than the default location shown in the dialog box,
click Change and enter the new location. When finished, click Next to
continue. A Ready to Install dialog box displays (Figure 6-3).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
DB Tool
6-3
Figure 6-3 Ready to Install dialog box
Step 5
Click Install. An Installing DB Tool dialog box displays briefly and then an
Installation Complete dialog box displays (Figure 6-4).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
6-4
DB Tool
Figure 6-4 Installation Complete dialog box
Step 6
Click Finish to complete the installation of DB Tool.
When uninstall of DB Tool is required, please open the Control Panel, select Add or
Remove Programs, select OW5000 DBTool, and then click Remove.
NOTE
Upgrade install is not supported for OW5000 DB Tool. When version up is required,
please open the Control Panel, select Add or Remove Programs, and then click
Remove.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
A-1
Appendix A
Backup and Rollback Procedure
The following information describes procedures that allow you to revert
to a previous version of OW5000. The following topics are included in
this chapter.
Chapter Topics
• Current Version Backup
• Rollback Procedures
Current Version Backup
Figure A-1 Backup Procedure
UCE Application Platform (UNIVERGE OW5000) Installation Guide
A-2
Backup and Rollback Procedure
Export Current Version Registry Key
Step 1
Start the Registry Editor using Start > Run > Regedit.
Step 2
Right-click on the NECAM folder at
(HKEY_LOCAL_MACHINE\SOFTWARE\NECAM) and select Export.
Figure A-2 Registry Editor dialog box
Step 3
An Export Registry File dialog box displays. Enter the proper export path
and file name and then click Save.
Backup Current Version Database
Step 1
Open a DOS command prompt for the current OW5000 server.
Step 2
Enter the SQL commands shown in the following illustration:

For OW5000 servers, backups of both the "OW5000" database and the
master database are required. The following figure uses OW5000R3.bak
and masterR3.bak as an example.
If the current version is OW5000 R3 with UA5200 Server 2.x or 3.x installed, you
should also backup the "Reports" and "AttStats" databases, if present.
NOTE
Move to the following folder before the command is used:
MS SQL Server 2005 Express Edition case
C:\Program Files\Microsoft SQL Server\90\Tools\Binn\
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Backup and Rollback Procedure
A-3
MS SQL Server 2008 Express Edition case
C:\Program Files\Microsoft SQL Server\100\Tools\Binn\
The default output folder of backup files are below:
MS SQL Server 2005 Express Edition case
C:\Program Files\Microsoft SQL Server\MSSQL.1\MSSQL\Backup\

MS SQL Server 2008 Express Edition case
C:\Program Files\Microsoft SQL
Server\MSSQL10.SQLEXPRESS\MSSQL\Backup\
(SQLEXPRESS might be different depending on the install
configuration)\
A different folder can be specified by supplying a path when using the TO
DISK command, as shown in this example: 
TO DISK='D:\SQLBackup\OW5000.bak'
UCE Application Platform (UNIVERGE OW5000) Installation Guide
A-4
Backup and Rollback Procedure
Rollback Procedures
Figure A-3 Rollback Procedure
Uninstall R4
Step 1
To uninstall R4 refer to “Uninstalling the OW5000 Platform” on page 224.
Delete NECAM Registry Key (R4)
NOTE
Step 1
Start the Registry Editor.
Step 2
Right-click on the NECAM folder
(HKEY_LOCAL_MACHINE\SOFTWARE\NECAM) and select Delete.
If an NEC folder exists at HKEY_LOCAL_MACHINE\SOFTWARE\NEC, it may
contain keys for UA5200 Attendant Statistics (attstats) or Guest Link, and/or
applications such as NEC's IMXMAT that is not part of the OW5000 suite of
applications. Carefully delete only those folders within the NEC key that were related
to your OW5000 R4 installation (.\NEC\attstats and .\NEC\Guest Link, for example, if
present).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Backup and Rollback Procedure
Step 3
A-5
Microsoft SQL Server 2008 is not supported by prior versions of
OW5000. If the OW5000 R4 database resides within Microsoft SQL
Server 2008, you'll have to uninstall the whole of Microsoft SQL Server
2008 (using Control Panel > Add or Remove Programs) prior to
reinstalling the older version of OW5000 with a supported version of
SQL.

If, on the other hand, the OW5000 R4 databases reside within Microsoft
SQL Server 2005, you need only use SQL Tools or SQL Server
Management Studio Management Express to delete R4's OW5000
database, if present. (This could be the case if OW5000 R4 was installed
to an existing SQL Server 2005.) 

Alternatively, if you are willing to re-install the version of SQL Server
(2000 or 2005) that was in use with the older version of OW5000, you
can just use Control Panel > Add or Remove Programs to remove the
whole of Microsoft SQL Server 2005, and then delete the "C:\Program
Files\Microsoft SQL Server" folder with all of its contents.
Restore NECAM Registry Key (old version)
Step 1
Restore the NECAM regedit export (a .reg file) that was created
previously by exporting
HKEY_LOCAL_MACHINE\SOFTWARE\NECAM. See “Export Current
Version Registry Key” on page A-2.
Step 2
Double-click the .reg file to import its contents to the Registry.
Install Platform and Other Applications (old version)
Step 1
Insert the USB security dongle that was in use with the older version of
OW5000.
Step 2
Install the old version of OW5000 Platform.
Step 3
Install any other applications that had previously been installed with the
old version of Platform.
Restore OW5000 database (old version)
Step 1
Select Start > Administrative Tools > Services and then stop the
following services:

OWWatch Dog
OW OAIMonitor (see Note)
Remote Call Control Service (if it is installed)
OW5000 Access Server (if it is installed)
UCE Application Platform (UNIVERGE OW5000) Installation Guide
A-6
Backup and Rollback Procedure
World Wide Web Publishing Service
OW5000 Application Message Service (R3)
All relative services are stopped.
NOTE
Step 2
Open the command prompt and delete the current database using the
following commands, as illustrated.
Move to the following folder before the command is used:

MS SQL Server 2005 Express Edition case
C:\Program Files\Microsoft SQL Server\90\Tools\Binn\
MS SQL Server 2008 Express Edition case
C:\Program Files\Microsoft SQL Server\100\Tools\Binn\
sqlcmd -S (local)\SQLEXPRESS
USE master
GO
DROP DATABASE OW5000
GO
Step 3
Restore the OW5000 database using the following commands, as
illustrated.

RESTORE DATBASE OW5000
FROM DISK = 'OW5000.bak'
GO
The following step works when the backup files are in the default folder; use FROM
DISL = parameter in case the backup file is there but in a different folder.
NOTE
Step 4
Select Start > Administrative Tools > Services, and double-click SQL
Server (SQLEXPRESS). A Property dialog box displays 
(Figure A-4).
Step 5
Stop the service by clicking the Stop button and then put -m in the Start
parameters field.
Step 6
Click Start.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Backup and Rollback Procedure
A-7
Figure A-4 Property dialog box
Step 7
After start up, restore the master database using the following command
from the Command Prompt:

RESTORE DATABASE master
FROM DISK = 'master.bak'
GO
exit
The following step works when the backup files are in the default folder; use FROM
DISL = parameter in case a backup file is there but in a different folder.
NOTE
Step 8
Select Start > Administrative Tools > Services, and double-click SQL
Server (SQLEXPRESS). A Property dialog box displays (Figure A-5).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
A-8
Backup and Rollback Procedure
Figure A-5 Property dialog box
Step 9
Click Start.
Step 10 If the rollback is from R4 to R3, the following command is also required to
enable the service broker.
ALTER DATABASE OW5000 SET ENABLE_BROKER
GO
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B-1
Appendix B
Microsoft SQL Server 2008 Express
Edition with Advanced Services
The following topics are included in this section.
• Microsoft SQL Server 2008 Express Edition with Advanced Services
Install
• Microsoft SQL 2008 Express Edition Uninstall
Microsoft SQL Server 2008 Express Edition with Advanced Services
Install
Microsoft SQL Server must be installed in advance of installing OW5000
Platform, on the same machine as OW5000 or on a different machine
within the same network.
If SQL Server 2005 or 2008 has not yet been installed for use with
OW5000 R4, please follow the instructions provided in this Appendix to
install Microsoft SQL Server 2008 Express Edition with Advanced
Services Install, using one of the Microsoft redistributables provided on
the UCE 2010 Disk 1 DVD (or install a Microsoft-licensed Standard or
Enterprise edition of SQL Server 2005 or 2008).
Prerequisites for Microsoft SQL 2008 Express Edition with
Advanced Services
Prior to installation of SQL Server 2008 Express Edition with Advanced
Services, the following three Microsoft redistributables must be installed
(or confirmed):
Microsoft .NET Framework 3.5 Service Pack 1
Microsoft Windows Installer 4.5 
Microsoft PowerShell 1.0
NOTE
NOTE
OS appropriate versions of the required Microsoft redistributables are included on
Disk 1 of the UCE 2010 DVDs. Inserting Disk 1 into a DVD drive will display a menu
with links for installation of these prerequisites.
For Windows Server 2008, Windows PowerShell 1.0 can be installed by using the
Add a Feature option in 2008 Server Manager. (PowerShell 1.0 is included with
Windows Server 2008.)
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B-2
Microsoft SQL Server 2008 Express Edition with Advanced Services
After installing the pre-requisites, a hardware-appropriate version of
Microsoft SQL Server 2008 Express Edition with Advanced Services can
be installed.
Microsoft redistributables for SQL Server 2008 Express Edition with
Advanced Services are included on Disk 1 of the UCE 2010 DVDs.
Inserting Disk 1 into a DVD drive will display a menu with links for
installation of the appropriate version (32-bit or 64-bit).
These can be installed on either Windows Server 2003 SP2, Windows
Server 2003 R2 SP2, Windows Server 2008 SP2, or Windows Server
2008 R2 SP2 machines.
To install the Microsoft SQL Server 2008 Express Edition with Advanced
Services, follow the steps below.
Step 1
Place the UCE 2010 Disk 1 DVD into the DVD-ROM drive and wait for
the installation menu to open.
Step 2
From the Prerequisites menu, select either the 32-bit or 64-bit link for
installing SQL Server 2008 Express Edition with Advanced Services. An
Extracting Files dialog box displays (Figure B-1).
Figure B-1 Extracting Files dialog box
Step 3
After the necessary files are extracted, Figure B-2 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-2 SQL Express Install dialog box
Step 4
Click Installation to display Figure B-3.
Figure B-3 Installation Options dialog box
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B-3
B-4
Microsoft SQL Server 2008 Express Edition with Advanced Services
Step 5
Click New SQL Server stand-alone installation or add features to an
existing installation to display a Setup Support Rules dialog box
(Figure B-4).
Figure B-4 Setup Support Rules dialog box
Step 6
Click Show details >> to examine any failed operations and respond
accordingly. Otherwise, click OK. A Product Key dialog box displays
(Figure B-5).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-5 Product Key dialog box
Step 7
Click Next to display a Software License Agreement 
(Figure B-6).
Figure B-6 Software License Agreement
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B-5
B-6
Microsoft SQL Server 2008 Express Edition with Advanced Services
Step 8
Read the software license agreement in the list box and click I accept
the license terms.
Step 9
Click Next. A Setup Support Files dialog box displays (Figure B-7).
Figure B-7 Setup Support Files dialog box
Step 10 Click Install. After all the components are installed, click Next to display
a Feature Selection dialog box (Figure B-8).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
B-7
Figure B-8 Feature Selection dialog box
Step 11
Click Select All and then click Next. (It is best to install every feature
now, during this initial install of SQL Server 2008 Express Edition with
Advanced Services than to add features later, as required by various
applications.) An Instance Configuration dialog box displays 
(Figure B-9).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B-8
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-9 Instance Configuration dialog box
Step 12 Click Next to display a Disk Space Requirements dialog box 
(Figure B-10).
Figure B-10 Disk Space Requirements dialog box
Step 13 Click Next to display a Server Configuration dialog box (Figure B-11).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
B-9
Figure B-11 Server Configuration dialog box
Step 14 Enter a Windows administrator Account Name and Password for the
SQL Server Database Engine (the first service listed), but use NT
AUTHORITY\NETWORK SERVICE as the Account Name for each of
the other services where entry of an Account Name is permitted. Select
Automatic Startup Type for the SQL Server Browser service, then click
Next. A Database Engine Configuration dialog box displays 
(Figure B-12).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B - 10
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-12 Database Engine Configuration dialog box
Step 15 Select Mixed Mode authentication, supplying a strong SA password (for
example, Ow5000db!) and writing it down for later reference.
NOTE
Do not use the default Windows authentication mode. Doing so can interfere with
the SQL connectivity of other UCE applications if they are installed on a different
machine at some time in the future.
Step 16 Click Add Current User and then click Next. A Reporting Services
Configuration dialog box displays (Figure B-13).
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
B - 11
Figure B-13 Reporting Services Configuration dialog box
Step 17 Select Install, but do not configure the report server then click Next.
An Error and Usage Reporting dialog box displays.
Figure B-14 Error and Usage Reporting dialog box
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B - 12
Microsoft SQL Server 2008 Express Edition with Advanced Services
Step 18 Click Next. Figure B-15 displays.
Figure B-15 Installation Rules dialog box
Step 19 Click Show details >> to examine any failed operations and respond
accordingly. Otherwise, click Next. A Ready to Install dialog box displays
(Figure B-16).
Figure B-16 Ready to Install dialog box
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
Step 20 Click Install. An Installation Progress dialog box displays 
(Figure B-17).
Figure B-17 Installation Progress dialog box
Step 21 Click Next to display a Complete dialog box (Figure B-18).
Figure B-18 Complete dialog box
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B - 13
B - 14
Microsoft SQL Server 2008 Express Edition with Advanced Services
Step 22 Click Close to complete the installation.
Step 23 From the Start menu, select All Programs > Microsoft SQL Server
2008 > Configuration Tools > SQL Server Configuration Manager.
Step 24 Expand the SQL Server Network Configuration branch, then click
Protocols for SQLEXPRESS (or the instance name created during
installation). Right-click the Named Pipes protocol. A Named Pipes
popup menu displays (Figure B-19).
Figure B-19 Named Pipes popup menu
Step 25 Select Enable. After a warning message displays, click OK.
Step 26 Right-click the TCP/IP protocol. A popup menu displays.
Figure B-20 SQL Server Configuration Manager
Step 27 Select Enable. After a warning message displays, click OK.
Step 28 Click on SQL Server Services, then right-click on SQL Server Browser
and select Properties. Figure B-21 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
B - 15
Figure B-21 SQL Server Browser Service—Automatic Startup Mode
Step 29 Move to the Service tab and confirm that the Start Mode for SQL Server
Browser was set to Automatic during installation of SQL. If not, change
the Start Mode from Manual to Automatic and then click OK.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B - 16
Microsoft SQL Server 2008 Express Edition with Advanced Services
Microsoft SQL 2008 Express Edition Uninstall
The Microsoft SQL Server 2008 Express Edition can be uninstalled using
the Windows operating system Add/Remove software function in the
Windows Control Panel.
Figure B-22 Uninstall SQL 2008 Express Server
Step 1
Select Microsoft SQL Server 2008 and click Change/Remove from the
Add or Remove Programs (Programs and Features for Windows 2008
Server). Figure B-23 displays.
Figure B-23 Remove dialog box
Step 2
Click Remove. Figure B-24 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-24 Setup Support Rules dialog box
Step 3
Click OK. Figure B-25 displays.
Figure B-25 Select Instance dialog box
VV
Step 4
Click Next. Figure B-26 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B - 17
B - 18
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-26 Select Features dialog box
Step 5
Click Select All and then click Next. Figure B-27 displays.
Figure B-27 Removal Rules dialog box
Step 6
Click Next. Figure B-28 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-28 Ready to Removed
Step 7
Click Remove. Figure B-29 displays.
Figure B-29 Removal Progress dialog box
Step 8
Click Next. Figure B-30 displays.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
B - 19
B - 20
Microsoft SQL Server 2008 Express Edition with Advanced Services
Figure B-30 Removal Progress—Continued dialog box
Step 9
Click Next. Figure B-31 displays.
Figure B-31 SQL Server 2009 Removal Confirmation dialog box
Step 10 Click Close.
UCE Application Platform (UNIVERGE OW5000) Installation Guide
NEC NEC Corporation
UC for Enterprise (UCE) Application Platform (UNIVERGE OW5000)
Installation Guide
NDA-31087 Issue 1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement