Lisun Catalog 2018
2018 Catalog
All Rights Reserved
Lisun Group (Hong Kong) Limited
Add: Room C, 15/F Hua Chiao Commercial Center, 678 Nathan Road, Mongkok, Kowloon, Hong Kong
Tel: 00852-68852050 Fax: 00852-30785638
Email: SalesHK@Lisungroup.com
Lisun Instruments Limited
Add: 113-114, No.1 Building, Nanxiang Zhidi Industry Park, No. 1101, Huyi Road, Jiading District, Shanghai, China
Tel: +86(21)51083341 Fax: +86(21)51083342
Email: SalesSH@Lisungroup.com
Lisun Sales Rep & Show Room (India)
Add: Plot No 362 Industrial Area, Phase II, PANCHKULA, HARYANA, PIN 134112, India
Email: Sales@Lisungroup.com
Lisun Sales Rep & Show Room (Korea)
Add: 2F, 20, Guui-ro, Gwangjin-gu, Seoul, Korea
Email: Sales@Lisungroup.com
FACEBOOK
FACEBOOK
Lisun Instruments Limited
Http://www.Lisungroup.com
LISUN GROUP
Company Profile
Lisun Instruments Limited was found by Lisun Group in 2003. We have sales & show room in
Shanghai, Russia, USA, India and Korea. In 2012, we built a high level products show room &
lab center in Shanghai. Lisun Group has set up a new manufactory in China to research and
develop the world high-technology CFL & LED Test Instruments. Its quality system has been
strictly certified by ISO9001:2008. The Lisun Group products have been authenticated by the
third party lab and were awarded by CE certificate. As a CIE Supportive Membership, all of
the test instruments produced by Lisun Group were designed according to CIE Standards.
Our main products are Goniophotometer, Spectrophotometer, Integrating Sphere,
Photometer and Colorimeter, LED Test Instruments, CFL Test Instruments, EMC Testing,
Electronic Ballast Tester, Equipments For Testing Electronic Components, Electrical Safety
Testing, Environmental Testing, AC and DC Power Supply and etc.
Lisun Group's products have been sold to more than 150 countries and regions in Europe,
America, Australia, Africa and Asia. Its quality was well accepted by many of world-famous
companies such as TUV, SGS, UL, GE, Philips, Sharp, OSRAM, SONY and so on. Lisun Group
wins thousands of customers' trust with motto "Right Product, Right Price and Right Service".
We will continue presenting more and more high quality products to our customers in future.
Right Product
Right Price
Right Service
Our Customers
LSG-2000 Goniophotometer in Europe
3m Integrating Sphere in Mexico
EMI and EMC Install & Training in India
LSG-1800B Goniophotometer in Germany
Environmental and Safety Test Chambers in Algeria
LSG-5000 Goniophotometer in USA
Lisun Instruments Limited
Http://www.Lisungroup.com
LISUN GROUP
CONTENTS
Part 1 Goniophotometer
LM-79 Goniophotometer System
LSG-5000, LSG-3000, LSG-2000
1
Goniophotometer for Automotive and Signal Lamps
LSG-1950, LSG-1950S
3
Near Field Moving Detector Goniophotometer
LSG-1900B
4
Rotation Luminaire Goniophotometer
LSG-1800B, LSG-1700B, LSG-1600B
5
Goniospectroradiometer
LSG-1800BCCD, LSG-1700BCCD
6
Compact Goniophotometer
LSG-1200A
7
Scientific Grade CCD Spectroradiometer
LMS-9500B, LMS-9500A
8
High Precision CCD Spectroradiometer
LMS-9000B
9
CCD Spectroradiometer
LMS-7000
10
Portable CCD Spectroradiometer
LMS-6000
11
Integrating Sphere with Testing Holder Base
IS-*MA
12
Integrating Sphere with Side Assistant Opening
IS-*MA**P, IS-*MA**C
13
Constant Temperature Integrating sphere
IS-*MT
14
CCD Spectroradiometer Sphere Compact System
LPCE-3
15
Integrating Sphere Spectroradiomter System for LED
LPCE-2
15
Optical Radiation Safety Test System
EN62471-C
16
LED Lumen Maintenance and Aging Life Test System
LEDLM-80PL
17
Lamp Start, Run-up time and Flicker Test
LSRF-2
18
Fast Photo-Electric Tester
LS616S
18
LED Power Driver Tester
WT2080
19
LED Driver Online Tester
LEDLS-60, LEDLS-12
20
DC Electric Load
M9822, M9822B
20
High Frequency Fluorescent Lamp Test System
HFP-800, RB-3, LPS-3
21
Adjustable Reference Ballast
DYJ-50HZ, DYJ-60HZ, DYJ-HID
22
Adjustable High Frequency Reference Ballast
HCS-109A
22
Multiplex Temperature Tester
TMP-8, TMP-16
22
Multiway Life Tester
CH316
23
Digital Torsion Meter
CH338
23
GNG-E27
24
Part 2 Spectroradiometer
Part 3 Integrating Sphere
Part 4 LED Test Instruments
Part 5 CFL Testing Instrument
“Go” and “Not Go” Gauge
Lisun Instruments Limited
Http://www.Lisungroup.com
LISUN GROUP
Part 6 EMC and EMI Test System
EMI Test System
EMI-9KC, EMI-9KB, EMI-9KA
24
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B, SDR-800S
24
Electrostatic Discharge Simulator
ESD61000-2
25
EFT Immunity Measurement
EFT61000-4
25
Surge Generator
SG61000-5
26
Impulse Withstand Voltage Tester
SUG255
26
Voltage Dips and Interruptions Generator
CSS61000-11
27
Magnetic Field Generator
PFM61000-8A
28
RF Conducted Immunity Test System
RFCI61000-4-6
28
Ring Wave Generator
RWG61000-12
29
Three Loop Antenna
VVLA-30M
29
Electronic Ballast Tester
WT5000
30
HID Ballast Tester
WT2000-HID
30
Electronic Ballast Automatic Test Equipment
ATE-1
30
Glow-wire Test Apparatus
ZRS-3HS, ZRS-3H
31
Needle Flame Test
ZY-3S, ZY-3
31
Horizontal Vertical Flame Tester
HVR-LSS, HVR-LS
32
Hot Wire Ignition tester
RSY-LT
32
Tracking Test Chamber
TTC-1
33
Temperature Meter for Lamp Caps & Luminaires Test
TMP-L
33
Automatic Safety Test System
LS9955, LS9956
34
Programmable Withstanding Voltage & Insulation Test
LS9923
34
High and Low Temperature & Humidity Chamber
GDJS-015A, GDJW-010A
35
Waterproof Testing Machine
JL-X
36
High Temperature & Pressure Jet Waterproof Test
JL-9K1L
37
Aging and Life Test Rack for CFL and LED
SY2036
37
Dustproof Testing Machine
SC-015
38
IK Level Tester
IK01-06, IK07-10
38
Salt Spray Test Machine
YWX/Q-010
39
Electrodynamic Vibration Generator System
LVD-100KG
39
UV Lamp Aging Test Chamber
UV-263LS
40
Xenon Lamp Aging Test Chamber
XD-80LS
40
Automatic Double Drop Test Machine
DT-63KG
40
Digital CC and CV DC Power Supply
DC3005, DC3005S
41
AC power Source
LSP-500VAR, LSP-500VAS
41
PWM Type AC Power Supply
LSP-3KVA, LSP-5KVA
42
Digital Power Meter
LS2008R, LS2010, LS2012, LS2050
42
Part 7 Electronic Ballast Tester
Part 8 Electrical Safety Test
Part 9 Environmental Test Chamber
Part 10 AC and DC Power Supply
Part 1 Goniophotometer
LISUN GROUP
LM-79 Goniophotometer Systems (LSG-5000, LSG-3000, LSG-2000)
According to LM-79 clause 9.3.1, only there are two kinds of type C goniophotometer can be accepted:
LSG-5000/LSG-3000 Moving Detector Goniophotometer and LSG-2000 Goniophotometer with Moving
Mirror. The LSG-5000/LSG-3000 and LSG-2000 are automatic light distribution intensity 3D curve testing
systems. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED
or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights
and other kinds of luminaries.
Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency,
Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves, Glare, Maximum Ratio
of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela
Diagrams, Efficient Luminescence Angle and so on.
Specification:
• The mirror or detector rotating the luminaires with an angle of (γ) ±180° (or 0~360°)
• The accuracy of angle: 0.05°, Resolution of angle: 0.001°
• Accuracy of photo detector: Constant temperature photo detector DIN5032-6/CIE pub1. No. 69 Class L
• The test result can be exported as CIE, IES, LDT and other format files. This kind of format files can
be transferred by other illumination and luminaire design software such as DiaLux
• The rotation motor is from Japan MITSUBISHI SERVO MOTORS and it uses Germanic Angle decode
system; It will help rotation smoothly and with high accuracy. It is very stable when start and stop.
• The LSG-5000/LSG-3000 completely meets the LM-80, LM-79, LM-75, GB, EN and CIE121-1996.
• Connect to PC via USB, English version software can be run in Win7, Win8 or Win10
• It can be an option working with an USB CCD Spectroradiometer to test spatial CCT Distribution and
other Spectral color parameters. We call this system as Goniospectroradiometer
Model Number
LSG-5000/LSG-2000
(Standard Size)
LSG-5000B/LSG-2000B
(Big Size)
LSG-5000S/LSG-3000B
LSG-2000S(Small Size)
Measure Non-Flood Lamp Φ1600*800mm, 50kg
Φ1400*500mm, 40kg
Φ1000*460mm, 30kg
Measure Flood Lamp
600*600mm, 50kg
600*600mm, 40kg
400*400mm, 30kg
Measure Power(W)
600V/10A, AC/DC
600V/10A, AC/DC
600V/10A, AC/DC
LSG-3000 is the cost-effective version of Moving Detector Goniophotometer
Test Report:
1
Part 1 Goniophotometer
LISUN GROUP
Test Principle:
LSG-5000/LSG-3000 Moving Detector Goniophotometer
LSG-2000 Goniophotometer with Rotating Mirror
2
Part 1 Goniophotometer
LISUN GROUP
Goniophotometer for Automotive and Signal Lamps (LSG-1950, LSG-1950S)
Measurement:
LSG-1950/LSG 1950S is the CIE A-α Goniophotometer which used to test automotive lighting
industry, traffic signal, bus, train, ship, and aircraft lighting. The photometer head keeps static and
face to the test sample while the test sample rotates around both horizontal axis and vertical axis,
so the luminous intensity and illuminance of the tested lamp or luminaires can be tested.
LSG-1950 Standard Version
LSG-1950S Economic Version
Specification:
•
•
•
•
•
•
It is designed according to EN, IEC, GB, ECE, SAE and FMVSS108
The accuracy of angle: 0.01°(LSG-1950) or 0.1° (LSG-1950S), Resolution of angle: 0.001°
Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 0.015cd~107cd(detector)
Accuracy of photometry: CIE Class A (Class L is option)
Testing Accuracy: 2% (Under Standard lamp); Stray Light: less than 0.1%
Can test max lamp up to 35kg and English version software can be run in Win7, Win8 and Win10
3
Part 1 Goniophotometer
LISUN GROUP
Near Field Moving Detector Goniophotometer (LSG-1900B)
LSG-1900B Goniophotometer is a near field Moving Detector goniophotometer which is for luminous
intensity distribution measurement. It fully meets LM-79 Clause 9.3.1 for industrial laboratory
photometric data measurements of small luminaires such as down light, bulb light and etc.
Specification:
• Meet the requirements of CIE, IEC, IES LM-79 & GB standards
• The luminaires will keep the burning point but not rotating during the testing
• The tested luminaries rotate around an angle of (γ)±180°(or 0~360°) and the tested luminaries
rotate around itself with an angle of (C)±180° (or 0~360°)
• Maximum size of testing luminaires: Φ300*550mm(diameter*depth), Weight: 20kg max
• Distance from lamp to detector: 1250mm
• Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 0.015cd~107cd(detector)
• The accuracy of angle: 0.1°, the resolution of angle: 0.01°
• Accuracy of photometry: CIE Class A (Class L is option)
• Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
• English version software can be run in Win7, Win8 or Win10
• This system can export data files as following formats: ies, ldt, cie, cib, tm4, cen, excel and so on.
This kind of format files can be transferred by luminaires design software such as DiaLux
4
Part 1 Goniophotometer
LISUN GROUP
Rotation Luminaire Goniophotometer (LSG-1800X, LSG-1800B, LSG-1700B, LSG-1600B)
The Rotation Luminaire Goniophotometer is an automatic goniophotometric measurement system for
measuring photometric parameters of luminaires, such as LED road lighting fixture, room lighting fixture
and projecting lighting fixture. The measured data meets IES standard format and can be applied in
lighting design by lighting design software. The measurement system fully satisfies the requirements
of lighting design work.
Measurement:
Luminous Intensity Data, Luminous Intensity Distribution, Zonal Luminous Flux, Luminaries Efficiency,
Luminance Distribution, Coefficient Of Utilization, Luminance Limitation Curves Glare, Maximum Ratio
of Distance to Height, Equal Illuminance Diagrams, Curves of Luminaires VS Lighting Area, Isocandela
Diagrams, Efficient Luminescence Angle, EEI, UGR and so on.
LSG-1800X/LSG-1800B use Japanese MITSUBISHI SERVO MOTORS and German Angle decode
Specification:
• Meet the requirements of CIE, IEC, IES LM-79 & GB standards
• Reach many measurement ways such as B-β and C-γ
• The tested luminaries rotate around an angle of (γ)±180°(or 0~360°) and the tested luminarie
rotates around itself with an angle of (C)±180° (or 0~360°)
• Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 0.015cd~107cd
• The accuracy of angle: 0.1° (LSG-1800X/LSG-1800B) and 0.2° (LSG-1700B/LSG-1600B)
• Accuracy of photometry: CIE Class A (Class L is option)
• Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
• English version software can be run in Win7, Win8 or Win10
• This system can export data files as following formats: ies, ldt, cie, cib, tm4, cen, excel and so on.
This kind of format files can be transferred by luminaire design software such as DiaLux.
Model Number
The max size for the Testing Lamp (Unit: mm)
C-Gamma Test with one Pillar
Max Weight
B-Beta Test with Two Pillars
LSG-1800X
Φ2500*550(Diameter*Depth)
700*600(Length*Width)
60kg
LSG-1800B
Φ1600*550(Diameter*Depth)
700*600(Length*Width)
50kg
LSG-1700B
Φ1600*550(Diameter*Depth)
700*600(Length*Width)
40kg
LSG-1600B
Φ1300*400(Diameter*Depth)
400*400(Length*Width)
30kg
5
Part 1 Goniophotometer
LISUN GROUP
Goniospectroradiometer (LSG-1800XCCD, LSG-1800BCCD, LSG-1700BCCD, LSG-1600BCCD)
The Goniospectroradiometer System can do the spatial CCT, CRI and other colorimetric parameters test
when do the intensity distribution test. It is for industrial laboratory measurements the photometric data
of luminaires such as LED luminaries, HID lamps, fluorescent lamps and so on.
High Precision CCD Spectroradiometer with fixture set
Goniospectroradiometer Test System
Specification:
• Meet the requirements of CIE, IEC, IES LM-79 & GB standards
• The Goniospectroradiometer system=Goniophotometer+Spectradiometer integrating Sphere system
• The tested luminaries rotate around an angle of (γ)±180°(or 0~360°) and the tested luminaries rotate
around itself with an angle of (C)±180°(or 0~360°)
• Luminosity Testing Range: Illuminance 0.001lx~99,999lx; Light Intensity 0.015cd~107cd
• The accuracy of angle: 0.1° (LSG-1800XCCD/LSG-1800BCCD) and 0.2° (LSG-1700BCCD/LSG-1600BCCD)
• Work with High Accuracy and quick CCD Spectraidomeeter to measure spatial color parameters.
• Accuracy of chromaticity coordinate: ±0.0015 or ±0.0005(under standard A lamp)
• Spectral Range Wavelength: 380nm~780nm; Accuracy of wavelength: ±0.5nm
• Accuracy of photometry: CIE Class A (Class L is for option)
• Testing Accuracy: 2%(Under Standard lamp); Stray Light: less than 0.1%
• English version software can be run in Win7, Win8 or Win10
Test Report:
P.S. The test files can be export as following formats: ies, ldt, cib, tm4, cie, cen, csv
6
Part 1 Goniophotometer
LISUN GROUP
Compact Goniophotometer (LSG-1200A)
The compact goniophotometer of LSG-1200A is applied to measure the luminous intensity distribution
curve, intensity data, spread angle and other parameters for chip LED, LED module, LED sportlight
and all other lights which beam angle is no more than 180 degree.
Option Function: The LSG-1200A can work with Digital Power Meter (LS2012 DC & AC Power Meter
or LS2010 Harmonic Analyzer), LSP Series AC Power Source or DC Series DC Power Source.
Specification:
Meet the requirements of IEC, CIE and LM-79 standards
Measure beam angle automatically: staple half intensity angle as well as 1/4 intensity angle, 3/4
intensity angle and 1/10 intensity angle which meets the special requirements.
Measured data are matched with international standard form (IES) and can be applied for lighting design
by other lighting design software such as DiaLux
LSG-1200A has included a dark chamber, measures the maximum size of lamps: 180mm
Test range of luminosity: 0.1~30,000lx. Test accuracy of detector: Class 1
The distance between the tested lamp and detector is 316mm/1000mm
Angle interval: Horizontal angle: 1°/5°/10°/15°/22.5°/30°/45°/90°, Vertical angle: 0.5°/2°/1.5°
The LSG-1200A horizontal automatic rotating on 0°~360° and Vertical automatic rotating on -90°~+90°
Test accuracy of angle: ±0.2°.
Illuminance
Photometric
7
Isocandela
Part 2 Spectroradiometer
LISUN GROUP
Scientific Grade CCD Spectroradiometer(LMS-9500B, LMS-9500A)
LMS-9500 Scientific Grade CCD Spectroradiometer fully meets Energy Star IESNA LM-79 and GB/T24824
standards etc. It is used to test CFL, HID, Promise Light, Tungsten Halogen Lamps, which can reach the
scientific grade measurement accuracy. LMS-9500 is composed of Concave Average Diffraction Grating
and Scientific Grade CCD, and uses unique stray light control technology, wide dynamic linear technology,
precision CCD electronic drive technology and complex matrix software technology. The instrument can
be traceable to the Chinese National Institute of Metrology(NIM) and the USA NIST standards.
Specification:
• CCD Detector: Hamamatsu TE cooled (Temp: 10°C ±0.05°C) high sensitivity back thinned CCD
(LMS 9500B), Hamamatsu high sensitivity back thinned CCD (LMS 9500A)
• Spectral Range Wavelength: 380nm~800nm (200~800nm and 380~1050nm are option)
• Spectral Wavelength Accuracy: ±0.2nm, Resolution: ±0.1nm, Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.0015
• Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.2%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear: ±0.2%, Stray light: <0.015%(600nm) and <0.03%(435nm)
• Time of integration: 0.1ms 60s
• Total flux testing method: Spectrum, Photometric and Spectrum with Photometric revision
• Spectrum senors: SMA905 optical fiber
8
Part 2 Spectroradiometer
LISUN GROUP
High Precision CCD Spectroradiometer (LMS-9000B)
LMS-9000B is adopting the world advanced Holographic grating with flat-field correction, precision optical
system and the electronic shutter control technology. The test speed can be in milliseconds and the test
accuracy is in the laboratory level. It has the lowest value of stray light. LMS-9000B has high repeatability and
stability testing. It fully meets CIE127-1997, IES LM-79-08 and IES LM-80-08.
Specification:
•
•
•
•
•
•
•
•
•
•
Spectral Range Wavelength: 380nm~800nm
Spectral Wavelength Accuracy: ±0.3nm, Resolution: ±0.1nm, Sample Scanning Steps: ±0.1nm
Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.002
Correlated Color Temperature CCT: 1,500K~100,000K, CCT Accuracy: ±0.3%
Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
Photometric linear: ±0.3%, Stray light: <0.015%(600nm) and <0.03%(435nm)
Time of integration: 0.1ms 20s
Total flux testing method: Spectrum, Photometric and Spectrum with Photometric revision
Spectrum senors: SMA905 optical fiber and Class A Photo detector
It can measure the temperature inside and outside of integrating sphere
LMS-9000B High Precision CCD Spectroradiometer
LMS-9000B uses the Band pass-filter Wheel Correcting Technique, Spectrometer & Broadband-radiometer
& photometer Combined Technique, and modified with NIST stray light correction technology, the
LMS-9000B can realize ultra low stray light and super photometry linearity in overall dynamic range.
9
Part 2 Spectroradiometer
LISUN GROUP
CCD Spectroradiometer (LMS-7000)
Typical Application:
The LMS-7000 works with LISUN a molding integrating sphere
to be an ALL-IN-ONE system to test single LED and LED
luminaires photometric, colorimetric and electrical parameters.
The test speed is quick and test results are very accuracy. It
fully meets CIE127-1997, IES LM-79-08 and IES LM-80-08.
The LMS-7000 is a cost-efficient CCD Spectroradiometer which
was widely used by the LED manufactory.
The LMS-7000 is quick and high accuracy testing. It has been
certificated by the third CNAS lab, the test results can be
traced to NIM and NIST.
:
LMS-7000UV
LMS-7000UV-VIS
LMS-7000VIS
200~400nm
200~950nm
350~950nm
LMS-7000VIS-NIR LMS-7000UV-VIS-NIR
380~1050nm
200~1050nm
Measurement:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant
Wavelength, Color Purity, CRI, Spectrum Test
• Photometric: Luminous Flux, Luminous Efficiency, Radiant Power
• Electric: Voltage, Current, Power, Power Factor
• LED optical maintenance test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS
time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
Specification:
•
•
•
•
•
•
•
•
Spectral Wavelength Accuracy: ±0.5nm, Resolution: ±0.2nm, Sample Scanning Steps: ±0.1nm
Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.003
Correlated Color Temperature CCT: 1,500K~25,000K, CCT Accuracy: ±0.5%
Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
Photometric linear: ±0.5%, Stray light: <0.015%(600nm) and <0.03%(435nm)
Time of integration: 0.1ms 5s
Spectrum senors: SMA905 optical fiber
Communicate with PC via USB2.0, the software can be run-in Win7, Win8 and Win10
Other Application:
The LMS-7000 works with other accessories, it can be used to do test and analysis in the following field
and area. We supply the DLL which allow you to do the system build-in and re-design functions.
10
Part 2 Spectroradiometer
LISUN GROUP
Portable CCD Spectroradiometer (LMS-6000)
Specification:
• Spectral platform: telephoto asymmetrical crossed CT system
• Spectral Wavelength Accuracy: ±0.5nm, Resolution: ±0.2nm, Sample Scanning Steps: ±0.1nm
• Accuracy of Chromaticity Coordinate (Δx, Δy): ±0.005
• Correlated Color Temperature CCT: 1,500K~25,000K, CCT Accuracy: ±0.6%
• Color Rendering Index Range: 0~100.0, Accuracy: ±(0.3%rd±0.3)
• Photometric linear: ±0.6%, Stray light: <0.015%(600nm) and <0.03%(435nm)
• Time of integration: 0.1ms 5s
• LCD screen: 5inch high definition IPS capacitive touch screen and resolution is up to 480*854
• With 4000mAh rechargeable Li-ion battery continuous working time 20 hours max
• The size (L*W) is similar to Iphone 6S and the thickness is similar to the diameter of 1RMB coin
• Include 8GB SD Card which can storage the test data, communicate with PC via software which can be
run in Win7, Win8 and Win10.
Measurement:
• LMS-6000: illuminance (lux), E(Fc), Ee(W/m2), Tc (K), Duv Correlated Color Temperature (CCT),
Chromaticity Coordinates, CRI, Purity, Peak Wavelength, Dominant Wavelength, Half Bandwidth, Center
Wavelength, Centroid Wavelength, Total Color Difference, Brightness Difference, Red-Green Degree,
Yellow-Blue Degree, CCT Difference, SDCM Diagram, Spectrum Diagram
• LMS-6000P: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance
Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb Ratio
• LMS-6000S: LMS-6000 Parameters+PAR, PPFD, YPFD, Blue-purple irradiance Eb, Yellow-green irradiance
Ey, Red-orange irradiance Er, Ratio of red and blue radiation Erb Ratio, Rf and Rg according to TM-30
• LMS-6000F: LMS-6000 Parameters+Flicker test
• LMS-6000B: LMS-6000 Parameters+Blue Light Hazard Weighted Irradiance according to GB/T20145, CIE
S009/E:2002
• LMS-6000BF: LMS-6000 Parameters+Flicker test, Blue Light Hazard Weighted Irradiance according to
GB/T20145, CIE S009/E:2002
Test Report:
11
Part 3 Integrating Sphere
LISUN GROUP
Integrating Sphere with Testing Holder Base (IS-*MA)
Due to the LED luminaries such as LED street luminaries developed, to do 4π geometry testing, it is hard
to be hold in the traditional integrating sphere design. To solve this problem, Lisun designed this new kind of
sphere.
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as
T5/T8/T12, and all kinds of luminaries
2. The hold base can be installed in the ceiling or down, it can be adjusted the height
3. Hold base has four power cables connected to the outside Power Supply and max is 5KW
4. The holder base is detachable. For some kinds of light sources you may need to change the position of
the holder base.
5. Diameter: IS-0.3M (Φ0.3m), IS-0.5M (Φ0.5m), IS-1.0MA (Φ1.0m), IS-1.5MA (Φ1.5m), IS-1.75MA
(Φ1.75m), IS-2.0MA (Φ2.0m). Other sizes can be designed according to the customer’s request.
6. The painting of integrating spheres is designed according to CIE Pub. No.84 (1989)
Integrating Sphere theory and Applications:
The integrating sphere works with a Spectroradiometer to do the photometry, colorimetry and
radiometry parameters measurement:
• IS-0.3M/IS-0.5M is suitable for LEDs, LED modules, High Power LED, mini bulbs and other small
lamps. The flux testing range is 0.001 to 1,999 lm
• IS-1.0MA is for suitable CFL or LED bulbs. The flux testing range is 0.1 to 199,990 lm
• IS-1.5MA/IS-1.75MA is suitable for CFL, LED bulb and tube, fluorescent lamp, CCFL. The flux testing
range is 0.1 to 1,999,900 lm
• IS-2.0MA is suitable for HID lamps or high power lamps. The flux testing range is 0.1 to 1,999,900lm
12
Part 3 Integrating Sphere
LISUN GROUP
Integrating Sphere with Side Assistant Opening (IS-*MA**P, IS-*MA**C)
According to IES LM-79 Clause 9.1.2, it requires the 4 geometry and 2 geometry configurating
Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant
Opening in A Molding Technology to meet the requirements.
The traditional integrating sphere is assembled by several pieces. Lisun Group developed A Molding
Technology to produce the sphere. A Molding Integrating Sphere will be more round and the test results
will be more accuracy than the traditional integrating sphere.
Figure: A Molding Integrating Sphere VS the traditional Integrating Sphere
Specification:
• Painting material of integrating spheres is designed according to CIE Pub.No.84(1989)
• The painting material is BaSO4 coating: ρ(λ)≥0.96(450nm~800nm) and ρ(λ)≥0.92(380nm~450nm)
• Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ(λ)<1.5%
• Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12
tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp
be tested up and down in the sphere.
• Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option).
• Two photo detector ports, one optical fiber port and temperature sensor hole are built-in
• Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is
0.5x0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C
(Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m).
Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request.
Fig: LM-79 Clause 9.1.2
13
Part 3 Integrating Sphere
LISUN GROUP
Constant Temperature Integrating Sphere (IS-*MT)
According to requirements of IEC standards, the standard test temperature is 25℃, but high power
lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the
temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group
designed the Constant Temperature Integrating Sphere which allows the lamp to be tested in a constant air
temperature.
Specification:
• Diameter: IS-0.3MT (Φ0.3m), IS-0.5MT (Φ0.5m), IS-1.0MT (Φ1.0m), IS-1.5MT (Φ1.5m), IS-1.75MT
(Φ1.75m), IS-2.0MT (Φ2.0m). Other size can be designed according to the customer’s request.
• Painting of integrating spheres is designed according to CIE Pub. No.84 (1989).
• Material: Pure barium soleplate (BaSO4).
• BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ)≥0.92 (380nm~450nm).
• Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ(λ)<1.5%.
• Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12
tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp
be tested up and down in the sphere.
• Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional.
• Power cable and socket has been build-in, it is convenient to power the testing lamp.
• Two photo detector ports, one optical fiber port and temperature sensor hole are built-in.
• Constant Temperature controlled range: 25°C~55°C (refer to the environmental temperature at 25°C).
A. Temperature Increasing tolerance: ±1°C
B. Temperature Down tolerance: ±2°C
Application:
The integrating sphere works with a Spectrophotometer to do the photometry, colorimetry and
radiometry parameters measurement:
• IS-0.3MT/IS-0.5MT is suitable for LEDs, LED modules, High Power LED, mini bulbs and other small
lamps. The flux testing range is 0.001 to 1,999 lm.
• IS-1.0MT is suitable for CFL or LED bulbs. The flux testing range is 0.1 to 199,990 lm.
• IS-1.5MT/IS-1.75MT is suitable for CFL, LED bulb and tube, fluorescent lamp, CCFL. The flux testing
range is 0.1 to 1,999,900 lm.
• IS-2.0MT is suitable for HID lamps or high power lamps. The flux testing range is 0.1 to 1,999,900 lm
UV-VIS High lndex of Reflective Coating
14
VIS High Index of Reflective Coating
Part 4 LED Test Instruments
LISUN GROUP
Spectroradiometer and Integrating Sphere Compact System for LED (LPCE-3)
Due to the LED Test System is hard to install and debug, LISUN developed a Spectroradiometer and
Integrating Sphere compact System LPCE-3. The LPCE-3 system combines the cabinet, test equipments
and integrating sphere together, so it allows the customers only to connect with PC and use the system
immediately but no need to install. In the other side, the compact system saves a lot of delivery cost.
The LPCE-3 is used for identifying the performance of single LEDs and LED lamps. LED's quality should
be tested by checking its photometric, colorimetric and electrical parameters. The LPCE-3 system fully
meets CIE127-1997, IES LM-79-08 and IES LM-80-08. The integrating sphere produced by A Molding
technology, it was built-in cross laser system and auxiliary position to improve the test accuracy.
ALL-IN-ONE LED Test System
1.
2.
3.
4.
5.
6.
7.
8.
9.
CCD Spectroradiometer
Big Integrating Sphere with Cabinet
Standard Lamp
Auxiliary Lamp
Digital Power Meter
AC Power Source
DC Power Supply
Optical Fiber
Mini PC(without Monitor)
PATENT
Integrating Sphere Spectroradiometer System (LPCE-2)
LPCE-2 is an Integrating Sphere Spectroradiometer Test System to test Energy-saving lamps, Fluorescent
lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps), CCFL and LED. The test
results meet the requirements of CIE and IES LM-79 for the measurement of photometry and colorimetry.
The LPCE-2 is applied with LMS-9000B/LMS-9500 CCD Spectroradiometer and a molding integrating
sphere with testing holder base function which will be more circle and the test results will be more accurate
than the traditional integrating sphere.
Measurement:
• Colorimetric: Chromaticity coordinates, CCT, Color Ratio, Peak Wavelength, Half Bandwidth, Dominant
Wavelength, Color Purity, CRI, CQS, TM-30, Spectrum Test
• Photometric: Luminous Flux, Efficiency, Radiant Power, EEI, Energy Efficiency Class, Pupil Flux,
Cirtopic Flux, PAR, PPF
• Electric: Voltage, Current, Power, Power Factor
• LED optical maintenance test according to LM-80: Flux VS time, CCT VS time, CRI VS time, Power VS
time, Power Factor VS time, Current VS time and Flux Efficiency VS time.
15
Part 4 LED Test Instruments
LISUN GROUP
Optical Radiation Safety Test System (EN62471-C)
The Optical Radiation Safety Test System is used to test the spectral power distribution,
radiance, irradiance, radiation exposure, specific effective radiant ultraviolet power (mW/klm),
illuminance, size of apparent source, CCT, color coordinate, CRI, SDCM and other parameters of
LED, LED modules, LED lamps, LED luminaires, fluorescent lamps, HID lamps, halogen lamps
and all other luminaires. The testing parameters include actinic UV hazard weighted
irradiance, near UV irradiance, retinal blue light hazard weighted radiance, retinal thermal
hazard, infrared irradiance, visible and infrared irradiance etc. The tested lamps and lamp
systems can be classified as per the photobiological hazard values.
The test system is designed according to the following standards: IEC62471, EN62471, CIE
S009, GB/T 20145, IEC/EN60598 Annex P., IEC/EN60432, GB7000.1, 2005/32/EC, EUP
directives and etc.
Fig. EN62471-C in dark room
Specification:
• Wavelength range: 200~800nm(EN62471-A), 200~1500nm(EN62471-B), 200~3000nm(EN62471-C)
• Radiance geometry: optics simulating human eye’s retina
• Acceptance aperture: Dia. 7mm for radiance; Dia. 20mm & 7mm for irradiance
• FOV range: 1.5mrad to 110mrad (1.7mrad, 11mrad, 100/110mard) according to exposure duration
of radiance measurement; 100mrad, 1.4rad and 6.28rad for irradiance measurement
• Testing distance: 200mm to 6.0m(optional) with constant FOVs and input aperture
• Image resolution:1600*1200
• Maximum exposure scanning range: 2pi-space
• Calibration: It can be traced to NIM
• Detectors: PMT/InGaAs/Si/PbS
• Imaging radiance meter: scientific grade 16bit CCD camera with TEC
• Sampling speed of pulse source:20us to 10s
• Wavelength accuracy: 0.1nm(UV), 0.2nm(VIS), 0.4nm(IR)
• Goniophotometer (LSG-1800B/LSG-1700B) is option
16
Part 4 LED Test Instruments
LISUN GROUP
LED Lumen Maintenance and Aging Life Test System (LEDLM-80PL)
LEDLM-80PL LED Lumen Maintenance and Aging Life Test System is designed according to standards of
IES-LM-80, IES-LM-82, TM-21 and GB2312-80, the software is developed base on Arrhenius model.
LED has the features of long life, but with the different working condition and drive current, its life will
be different, but generally the life will be around 50K hours. Differ from the traditional lightsource, LED
light will decay gradually rather than extinguish instantly, so in the standard of LM-80, it introduces L70,
L50 and etc.
1) L70 (hour): time to 70% lumen maintenance
2) L50 (hour): time to 50% lumen maintenance
Features:
1) Record the changing curves of lumen VS time, and colorimetric parameters VS time
2) Test and record the light attenuation data within a short time, then software will predict the LED life
3) Introduce the Arrhenius Model to make the test result more reliable and effective
System Configuration:
LM-80PL LED Aging Control System with Arrhenius software, TMP-8 Multiplex Temperature Meter,
LMS-4000 Quick Test System for Photo and Color, CFO-1.5M Optical Fiber, LS2008R Digital Power Meter,
LSP-18CH The Switching Power System for the LED lamp, CASE-19IN Cabinet
The Life Calculated by TM-21:
P.S The LEDLM-80PL needs to work with a GDJW Series High/Low Temperature Chamber and a LSP
Series AC Power Source.
Lumen Maintenance Life Prediction Report
Lumen Maintenance Graph
17
Part 4 LED Test Instruments
LISUN GROUP
Lamp Start, Run-up time and Flicker Test System (LSRF-2)
Dated 14th December, 2012, the EU officially released the (EU) NO.1194/2012 rules <Implementing rules
of the European Parliament and the EU Council Directive 2009/125/EC on the eco-design requirements of
directional lights, LED lights and related equipment requirements>. Compared with <European
Parliament and Council Directive 2005/32/EC implementing rules for non-directional household lamps
eco-design requirements> which posted by the European Commission Regulation (EC) NO 244/2009
Regulations dated 18th March, 2009, the new rules have complete mandatory and eco-design
requirements. Start and Run-up time as the two indicators functional requirements in the industry have
been more emphasis by manufacturers.
To meet EU ErP requirements, IEC60969 Selfballasted Lamps for General Lighting Services
Performance requirements and Energy Star. LISUN
developed ErP test system LSRF-2 to test the Lamp
Start, Run-up Time and Lamp Flick.
The LSRF-2 system can be an option function for
LISUN LPCE-2 or LPCE-3 Integrating Sphere and
Spectroradiometer Test System.
The integrating sphere & calibrate lamp are option
Fast Photo-Electric Tester (LS616S)
The LS616S is designed in a Luggage which can be taken out conveniently. The LS616S can be used to test
the CFL, Single LED, LED Spotlight and LED bulb which lamp holder is E27, E40, MR16 and so on.
Specification:
18
Part 4 LED Test Instruments
LISUN GROUP
LED Power Driver Tester (WT2080)
WT2080 LED Power Driver Test Instrument is the comprehensive test instrument for LED Power
Driver which is according to GB/T 24825-2009 and IEC 62384:2006. It can measure the following
parameters: Input Characteristics Test (AC&DC), Output Characteristics Test (AC&DC), Output
Start Characteristics Test (DC) and Harmonic Test.
The WT2080 usually works with LISUN LSP-500VAR pure sine AC Power Source and LISUN M9822
DC Electronic Load to test LED Driver. The software can be run Win7, Win8 and Win10.
Specification:
1. Input Characteristics Test (AC)
• To measure the input voltage, current, power, power factor, power grid frequency
• The fundamental frequency scope of the current and voltage: 45Hz~65Hz; Narrow band range:
45Hz~5kHz; Broadband range: 45Hz~1MHz.
• U range: 3~300V (CF=1.67); Current: 5mA~2.7A (CF=3); Power: 0.015~800W; PF: 0.000~+1.000.
2. Input Characteristics Test (DC)
• Measuring voltage, current, power.
• Voltage range: 3~500V; Current range: 5mA~8A; Power range: 0.015~4KW
3. Output Characteristics Test (AC)
• Measuring lamp voltage, lamp current and lamp power.
• Lamp U range: 3~300V(CF=3); Lamp I range: 5mA~2.7A(CF=3); Lamp P range: 0.015~800W
4. Output Characteristics Test (DC)
• Measuring output lamp voltage, lamp current, lamp power, ripple wave current.
• U range: 3~500V; I range: 5mA~8A; P: 0.015~4KW; Ripple wave current: 5mA~2.5A.
5. Output Start Characteristics Test (DC)
• Change curve and data of the measuring lamp voltage and lamp current within 0~2 seconds.
• Lamp voltage range: 3~500V; Lamp current range: 5mA~8A
6. Harmonic Testing
• Total harmonic components test of 0~50times, wave ratio, initial phase angle and peak phase angle
Input Characteristics
Start Characteristics
19
Input & Output Characteristics
Part 4 LED Test Instruments
LISUN GROUP
LED Driver Online Tester (LEDLS-60, LEDLS-12)
LEDLS-60/LEDLS-12 LED Driver Online Tester is applied to the production line for the finished products
testing. With features of simplified operation and nice-looking, the workers can operate it at very short
time. This system can meet the requirements of IEC62384, GB24825-2009 and other relative standards.
Specification:
• The LEDLS-12 has one channel which can test 6 LED Driver input and output parameters at one time (or
12 LED Driver input or output parameters at one time).
• The LEDLS-60 has ten channels which can test 60 LED Driver input and output parameters at one time.
• The tester can measure the following parameters:
1). Input Parameter Test (AC) in RMS value: U, I, P, PF, Hz, THD
2). Output Parameter Test (AC/DC) in RMS or Average value: U, I, P, PF, Efficiency, Ripple Wave Current
3). The Hardmonic Test: THD and harmonic components test of 2, 3, 5, 7, 9 and 11 (total 50 is option)
• The LEDLS-60 has 8inch LCD screen to display all of the test parameters, the LEDLS-12 has 12 windows
to display all the test parameters
• The test speed is quick: The LEDLS-60 needs only 20s include the LED load light on and test. The
LEDLS-12 needs only 2s include the LED load light on the test
• They only need to connect six LED DC electric load (LISUN M9822) or LED lamp to do test
• It allows to set upper or lower limit, it will have Noisy/Light warning if the test results were over limit.
• The manual trigger and software connect to PC to storage test results are option (extra cost)
DC Electric Load (M9822, M9822B)
M9822/M9822B is newly designed circuit adopts rapid AD and DA technology to achieve rapid
measurements with high accuracy. And the resolution of 0.1mV/0.1mA can effectively display the
minor change of voltage and current, so the instrument has a wider application field and achieves
better test results.
The new CR-LED test mode can be a real simulation of LED
light features set by the increase in the diode turn-on voltage,
fully simulate the working principle of the diode, so that the
test voltage and current to achieve a normal and stable value,
to avoid the traditional fixed resistor mode under voltage and
current instability or shock, the real reflect the LED drive
power load situation.
Specification:
•
•
•
•
•
•
•
•
•
•
.
Input voltage: 0~150V(M9822) or 0~500V(M9822B); Input current: 1mA~30A; Input power: 300W
CR-LED measurement mode, fully simulate the load characteristics of LED power
High-light and high-visibility VFD display
High resolution of 0.1mV and 0.1mA
Test functions of OCP and OPP can accurately capture critical parameters
Modes of CC, CV, CR, CP
Battery test mode can automatically record the discharge time and the capacity
The dynamic transition time of 0.1mA can effectively detect the power dynamic response.
List test can flexibly set test mode and time and finally judge the test result
Remote test function and multiple groups of data storage
20
Part 5 CFL Test Instruments
LISUN GROUP
High Frequency Fluorescent Lamp Test System(HFP-800, RB-3 and LPS-3)
This High Frequency Fluorescent Lamp Test System includes HFP-800 (High Frequency Power Supply ),
LPS-3 (Auxiliary Power Supply) and RB-3 (Adjustable Resistance Ballast). This system is applied to all
kinds of fluorescent lamp such as 50Hz/60Hz T8/T12 or 25KHz T5 Tube test. The system is according
to Double end fluorescent lamp adopts the IEC 60081 (GB/T10682) and the single-ended fluorescent
lamp adopts the IEC60901 (GB/T17262), where in the standard of electricity parameters as in Fig 1
S2
S3
A
Adjustable Resistance Ballast
RB-3
Tube
S1
Metal Board to Earth
HFP 800 High Frequency Power Source
LPS-3
Lamp Preheat Assistant Source
A
Fig 1 Preheating Method of Cathode High Frequency Fluorescent Lamp
High Frequency Power Supply (HFP-800):
output frequency is 20~26kHz (meets the requirements
of IEC 60081:1997), the frequency should be kept in
the range of ±2% at working. Output Power Range
is 10~600V (Adjustable). Range for output current:
0~0.600A. Range for output power: 0~300W
Adjustable Resistance Ballast (RB-3):
impedance values of high frequency reference
ballast which used by any high frequency lamp with
regard to GB/T10682 (IEC 60081) and GB/T17262
(IEC60901), RB-3 conforms to the requirements of
IEC60929 and ANSI C82.11. Available current range:
0~0.700A. Impedance range: 100~2047Ω
Lamp Preheat Assistant Source | Auxiliary
Power Supply (LPS-3): Preheating method of
cathode during the high frequency fluorescent lamp
starting. Adjustable pre-heat time for filament is
0~10.00s.
21
A
Part 5 CFL Test Instruments
LISUN GROUP
Adjustable Reference Ballast (DYJ-50HZ, DYJ-60HZ, DYJ-HID)
According to double end fluorescent lamp of IEC 60081 (GB/T10682), the single-ended
fluorescent lamp of IEC60901 (GB/T17262), ANSI C78.81 and ANSI C82.3, DYJ Reference Ballast is
used to test for 4W~85W fluorescent lamp and electronic ballast test.
Specification:
• Inductance: 0~1240Ω (adjustable)
• Inductance Power Factor COSφ: 0.075~0.120
• Resistance: 0~111Ω (adjustable)
• Current Range 0.150~0.670A (Imax: 1A)
• Order Code: DYJ-50HZ is for 50Hz lamp test
and DYJ-60HZ is for both 50 and 60Hz lamps test.
According to IEC60188, IEC60662 and ANSI C82.5, Lisun Group developed the DYJ-HID Standard Ballast
(Reference Ballast) to test the HID lamp, HID ballast, High-Voltage Mercury Lamp, High Voltage Sodium
Lamp, Metal Halide Lamp and Halide Reactor. More information, please contact Lisun Group.
Adjustable High Frequency Reference Ballast (HCS-109A)
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current
Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is
economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test
System. It can also measure the photo, color and electricity parameters for high frequency
fluorescent lamp.
Application:
• According to UL1993, HCS-109A is used to do input, temperature rise, leakage current and harmonic
distortion test for LED Type A tube direct replacement fluorescent tube.
• According to GB/T 10682-2002 and IEC 60081:1997, HCS-109A is used to test the high frequency
fluorescent lamp such as T5 tube (How to Measure the High Frequency Fluorescent Lamp), power
frequency fluorescent lamp such as T8/T12 tube.
Specification:
• Input voltage: 200V~240V, 50/60Hz
• Input Power: 80 W max
• Output Current: 130mA~400mA (Adjustable)+/- 1%
• Output Frequency: 25kHz< +/-2.0% (Adjustable),
accuracy: +/- 0.3kHz
• Output current total harmonic wave distortion:
THD<2.5% (HF current wave)
Multiplex Temperature Tester (TMP-8, TMP-16)
Specification:
• 8 channels temperature signal(TMP-8) or 16 channels
temperature signal(TMP-16)
• K type thermocouple
• Temperature range: -40~300°C. Testing accuracy: 0.5%
• Channel sequence is displayed by 2 LED and temperature is
displayed by 4 LED
• Freely set up the software with PC and record the change of
temperature and select the channel.
22
Part 5 CFL Test Instruments
LISUN GROUP
Multiway Life Tester (CH316)
Feature:
• Measure 16 samples at the same time, evaluate and record the
life of each sample.
• Very flexible: Samples can be added and changed at anytime.
• The life of each sample is readable at anytime.
• The switch ON/OFF time is adjustable (Test period is min 1s).
• Automatically remember the test result when the power is off,
and resume the old measurement when power is on.
• Sound and light alarm when the products were failed.
Specification:
• Current range (normal load): 30mA~1000mA (RMS). Invalid if the load current is smaller than 30mA.
• Tested sample life range: 0~1,000,000 times.
• Switch on or switch off time can be set at: 1 second~99 hours 59 minutes 59 seconds.
Digital Torsion Meter (CH338)
Digital Torsion Meter is mostly applied to measure the torque of all kinds of luminiares lamp cap. The
CH338 is a newly developed intelligent product with microprocessor built-in.
Specification:
• Range: 0~10N•m; Accuracy≤1%
• Repeatability≤0.5%FS; Over loading: 120%FS
• It can measure the clockwise and anti-clockwise torque of lamp
cap and it can preset upper limit alarm. The data won’t be lost
after shutting down the instrument.
• Instrument is convenient to be used because it has several
mating clamps of various lamp caps such as E27/E26, B22d,
E14/E12, G13/G5 and so on.
"Go" and "Not Go" gauge (GNG-E27)
Specification:
According to the requirement of IEC60061, Lisun produced high
accuracy and high quality "Go" and "Not go" gauge
• GNG-E27 is for E27 lamp cap standard source measurement. It
includes 7006-27B-1, 7006-28A-1, 7006-27C-1, 7006-50-1, 7006
-51A-2, 7006-51-2
• GNG-E27H is for E27 lamp holder standard source measurement.
It includes 7006-25A-2, 7006-26-4, 7006-21-5, 7006-22A-4, 7006
-22B-1, 7006-22C-1, 7006-22D-1
• GNG-E14 is for E14 lamp cap standard source measurement:
7006-27F-1, 7006-54-2, 7006-27G-1, 7006-55-2
• GNG-E40 is for E40 lamp cap standard source measurement:
7006-27-7, 7006-28D-1, 7006-52-1, 7006-53-1
• GNG-B22D is for B22d lamp cap standard source measurement:
7006-12-8, 7006-15-7, 7006-20-4, 7006-12A-2, 7006-12B-2,
7006-15A-2, 7006-13-5, 7006-17B-1
• GNG-B22DH is for B22d lamp holder standard source
measurement: 7006-12A-2,7006-12B-2,7006-15A-2,7005-10-8
23
Part 6 EMC and EMI Test System
LISUN GROUP
EMI Receiver System (EMI-9KC, EMI-9KB, EMI-9KA)
EMI-9KB is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference)
testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material,
which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument
self-EMI problem. The test results are according to the international format test report. The EMI Test System
EMI-9KB fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
Specification:
• Detection frequency range:9kHz~30MHz (EMI-9KA) or
9kHz~300MHz (EMI-9KB) or 9kHz~1GHz (EMI-9KC)
• Frequency stability: 1x 10 6
• Frequency resolution: (9kHz~150kHz) 30Hz;
(150kHz~30MHz) 1kHz
• Test Tolerance: ±2dB
• Measure and detection method: PK, QP and AV
• Measure range from 20dBμV to 140dBμV
• Frequency scanning step length: 20Hz~2MHz
• Sweep bandwidth: 200Hz; 9kHz; 120kHz
• Connect PC via USB and software can be run Win7, Win8.
Magnetic Shielding Cabinet for EMI Testing (SDR-2000B)
The SDR-2000B and SDR-800S Magnetic Shielding Cabinet is designed
according to GB/T12190:2006, GJB5792:2006, IEEE std299 and
EN50147. The shielding cabinet is tested based 9K~100K>70db and
100K~300MHz>100db. The SDR-2000B and SDR-800S can work with
EMI-9KA/EMI-9KB to reduce the testing load self or environmental EMI.
Specification:
Product Model
EMI-9KA/EMI-9KB
SDR-2000B
SDR-800S
EMI-9KA/EMI-9KB, PC, Testing load and
operator are put inside
Testing load is put inside to connect with
EMI-9KA/EMI-9KB via BNC
Note: Other size Shielding cabinet can be designed according to customer’s request
24
Part 6 EMC and EMI Test System
LISUN GROUP
Electrostatic Discharge Simulator (ESD61000-2)
ESD simulator (Electrostatic Discharge Generator or Electrostatic
Gun) is in full compliance with IEC 61000-4-2, EN61000-4-2,
ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322.
The ESD generator is designed for the assessment of electrical and
electronic equipment to withstand ESD performance. ESD61000-2
/ESD61000-2A has LCD display in both English and Chinese, they are
equipped with an infrared remote control which can allow you do
the test in some special place.
Touch screen with super big LCD and built-in Windows CE
Specification:
ESD61000-2A
ESD61000-2
Product Model
Output Voltage
0.1~20kV±5%
0.1~30kV±5%
Polarity
Positive/Negative
Positive/Negative
Energy Storage Capacitance 150pF±10% (Replaceable)
150pF±10% (Replaceable)
Discharge Resistor
330Ω±5% (Replaceable)
330Ω±5% (Replaceable)
Current Rise Time
0.6~1ns
0.6~1ns
Testing Functions
Single, Count, 20pps, Air, Contact, IEC level Single, Count, 20pps, Air, Contact, IEC level
Trigger Mode
MANUAL/AUTO
MANUAL/AUTO
Numbers of Discharge
1~9999
1~9999
Repetition
0.05s~99.99s
0.05s~99.99s
Working Power
AC220V(Option 110V)±10%, 50/60Hz
AC220V(Option 110V)±10%, 50/60Hz
EFT Immunity Measurement (EFT61000-4)
EFT immunity tester EFT61000-4 is specially designed according to the characteristics and requirements of
EFT measurement and it is an ideal disturbance source of EMS measurement. They have fine performance,
such as high stability, high reliability, easy to use and etc. It meets the standard requirements of IEC 61000
-4-4, EN 61000-4-4, GB/T17215.301, GB/T17215.322 and GB/T17626.4. EFT61000-4 has LCD display in
both English and Chinese.
Specification:
• Output voltage: 0~5000V
• Pulse frequency: 1kHz~1000kHz (Adjustable)
• Polarity: Positive, Negative or Positive/Negative, auto
• Source impedance: 50Ω±20% and 1000Ω±20%
• Rise time of a pulse: 5ns±30%
• Pulse width: 50Ω is 50ns±30%, 1kΩ is 35ns~150ns
• Burst duration: 0.01ms~20ms
• Burst period: 100ms~500ms, Test time: 1s~9999s
• Testing functions: Set test mode freely or IEC Level
• Coupling/Decoupling Network: Built-in 20A with
3 phases/5 wires
• Working Power: AC220V (Option 110V), 50/60Hz
25
Touch screen with super big LCD
and built-in Windows CE
Part 6 EMC and EMI Test System
LISUN GROUP
Surge Generator (SG61000-5)
Automatic lightning surge generator (or Lightning surge
immunity) SG61000-5 is used to assess the power cord
and connect the internal switch stood in line to connect
the internal switch to provide a common basis for switching
the natural world and lightning caused by the high-energy
transient interference performance. It fully meets the
IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
Touch screen with super big LCD
and built-in Windows CE
Specification:
SG61000-5T
SG61000-5
Product Model
SG61000-5H12
SG61000-5H
Output Voltage (Open) 1.2/50μs±20%
1.2/50μs±20%
1.2/50μs±20%
1.2/50μs±20%
Output Current (Short) 8/20μs±20%
8/20μs±20%
8/20μs±20%
8/20μs±20%
Output Impedance
2Ω
2Ω
2Ω and 500Ω
2Ω and 500Ω
Output Voltage Range
0~6KV±10%
0~6KV±10%
0~12KV±10%
0~10KV±10%
Output Current Range
0~3KA±10%
0~3KA±10%
0~6KA±10%
0~5KA±10%
Surge Repetition
1~9999 times
1~9999 times
1~9999 times
1~9999 times
Interval Time
20~9999s
20~9999s
20~9999s
20~9999s
Polarity
Positive, Negative or Positive/Negative automatic
Phase Shift
Asynchronous, Synchronization 0°~ 360° or Specific Angle
Coupling/Decoupling
Network (CDN)
Includes a 16A
single phase CDN
Includes a 20A
3phases CDN
Includes a 30A
3phases CDN
Built-in 20A
3phases CDN
Package Size/
Gross Weight
44x45x35cm
About 30kg
44x45x55cm
About 48kg
56x69x165cm
About 300kg
56x69x155cm
About 270kg
Impulse Withstand Voltage Tester (SUG255LX, SUG255PX)
The Impulse Withstand Voltage Tester (or High Voltage
Surge Generator) is designed according to IEC255-5,
IEC60060, GB14711, GBT17215.301 and GBT17215.322.
It is suitable for doing all kinds of electrical and electronic
products insulation performance test.
Specification:
SUG255LX
Product Model
SUG255PX
Voltage Output Waveform
1.2/50μs
1.2/50μs
Range of Output Voltage
0~12kV
0~12kV
Polarity of Output Voltage
Positive or Negative
Positive or Negative
Impedance of Generator
12Ω and 500Ω
2Ω and 500Ω
Operation Mode
Manually or Automatic
Manually or Automatic
Test Repetition
1~9999
1~9999
Interval Time
3~9999s
3~9999s
26
Part 6 EMC and EMI Test System
LISUN GROUP
Voltage Dips and Interruptions Generator (CSS61000-11)
The voltage dip and interruptions generator is specially designed according to the characteristics and
requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point,
CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have
more fine performance such as high reliability, convenient operation, and fully meet the standard
requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11
Touch screen with super big LCD and built-in Windows CE
Specification:
CSS61000-11
CSS61000-11T
AC Sine Wave
AC Sine Wave
0~110% of 220V
0~110% of 380V
100%, 80%, 70%, 40%, 0%
100%, 80%, 70%, 40%, 0%
0°~360°(1° Step)
0°~360°(1° Step)
Duration Time of Voltage
Variation
0.5~9999.5T
0.5~9999.5T
Internal Time of Voltage
Variation
1s~9999s
1s~9999s
Voltage Dip Count
0~9999 times
0~9999 times
Operating Mode
Automatic Dip
Choose 1 to 3 phases to automatic
dip at the same time
Product Model
Wave Generator
Range of Voltage Variations
IEC Level Build-in
Dip Phase Set
Trigger Mode
Power Capacity For EUT
Working Power
Manual, Auto and 50ms
Manual, Auto and 50ms
Single Phase AC 220V±10%, 16A max 3 Phase AC 380V±10%, 20A max
AC220V(Option 110V)±10%, 50/60Hz
Dimension (DxWxH)
44x45x90cm
56x58x130cm
Gross Weight
About 90kg
About 150kg
27
Part 6 EMC and EMI Test System
LISUN GROUP
RF Conducted Immunity Test System (RFCI61000-4-6)
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction
sensitivity testing, it fully meets IEC61000-4-6.2006, ISO11452-4
Specification:
• Main Instrument: Programmable signal
source and 20 w linear power amplifier
• Attenuator: 50W/6dB(50Ω)
• Coupling/decoupling network :
CDN (RFCI61000-4-6CDN) or
EM(RFCI61000-4-6EM)
• Cable Jumper: One meter N-N(50Ω)and one USB
• Frequency range: 150K~230M;
• Calibration for continuous wave:
1V(120dBμ), 3V(130dBμ), 10V(140dBμ);
• 80% AM radio frequency modulation signal
(modulation frequency is 1k) when testing;
• Frequency step: Segmentation step,
specific steps as below: 150K~1M(10K),
1M~30M(1M) and 30M~230M(10M), the
proportion step (1%~100% adjustable);
• Dwell time: 1s~120s (adjustable);
• Output power error: ±1dB
Magnetic Field Generator (PFM61000-8A)
PFM61000-8A Magnetic Field Generator is high reliability test equipment with stable performance, specially
designed for electrical and electronic products for measuring immunity characteristics and requirements of
normal frequency magnetic fields. It fully meets IEC61000-4-8 and GB / T17626.8 standards.
Specification:
• LCD display, built-in PC for controlling, easy to operate.
• Freely set the time of current injection and interval,
and the time of test.
• Intelligently acquire current, voltage and magnetic
field strength, all the parameters will be showed on
the LCD display.
• Magnetic field coil: 1 square meter (others can be
customized)
• Magnetic field strength: 0A/m~1000A/m continuously
adjustable
• Output Current: AC
• The time of test: 999 times
• Test of interval: 1~99min
• Current injection time: 1s to 99min
• Current distortion rate: <5%
• Work mode (current range for continuous working):
1A~100A
• Work mode (current range for short-time working):
>100A~500A is 1~5s and >500A~1000A is 1~3s
• Methods of operation: manual, semi-automatic,
automatic
• Power supply: AC220V 50/60Hz
• Working environment temperature: 15°C-35°C
28
Part 6 EMC and EMI Test System
LISUN GROUP
Ring Wave Generator (RWG61000-12)
Ring Wave Generator is the test equipment in conformity to
IEC61000-4-12, EN61000-4-12, ANSI-C62-41. This
instrument is used for the simulative electrical network,
the power supply of the reactive load and the control line
switch, as well as sensing the ring wave of the low voltage
cables terminal equipment caused by the disconnection of
the power circuit, fault and insulation breakdown or
lightning stroke. The RWG61000-12 series products have
LCD display in both English and Chinese.
Touch screen with super big LCD and built-in Windows CE
Specification:
Product Model
RWG61000-12
Output Voltage
RWG61000-12T
0~4KV
RWG61000-12A
RWG61000-12AT
0~6KV (Special Order)
Voltage/Current Wave
Open circuit voltage wave: frontier: 0.5μs±20%. Short circuit current wave:
frontier: ≤1μs. Oscillation frequency: 100kHz±10%
Polarity
Positive, Negative or Positive/Negative automatic
Phase Shift
Asynchronous, Synchronization 0°~360° or Specific Angle
Output Impedance
12Ω, 30Ω
Coupling/Decoupling
Network (CDN)
Includes a 16A
single phase
Working Power
AC220V(Option 110V)±10%, 50/60Hz
Dimension (DxWxH)
44x45x35cm
Gross Weight
About 28kg
Includes a 20A
3phases/5wires
Includes a 16A
single phase
Includes a 20A
3phases/5wires
44x45x20cm
44x45x30cm
44x45x30cm
44x45x35cm(CDN) 44x45x20cm(CDN) 44x45x35cm(CDN)
About 46kg
About 45kg
About 48kg
Order Noted:
1. The RWG61000-12 can be assembly with SG61000-5 in one unit to down the cost
2. The 0~6KV Ring Wave Generator is special designed according to the customer’s request
Three Loop Antenna (VVLA-30M)
Specification:
• The three loop antenna VVLA-30M is a standard measurement antenna
according to CISPR15-2005. it can coordinate LISUN GROUP EMI- 9KB,
EMI-9KA EMI Receiver System for EUT magnetic field radiation test
measurement between X, Y and Z planes
• Frequency range: 9KHz ~30MHz
• It can switch between X, Y and Z planes
• The sensor coefficient of current probe is 0dB
• Impedance: 50Ω/BNC
• The antenna Ring diameter: 2m
• The volume of antenna: 2.4*2.4*2.5m
• It can provide non metal base with various heights (capacity is 6kg)
• No need to move EUT or loop during measurement process
• The shielded room influence on the test result is greatly reduced
• Interference in open area test environment is greatly reduced
29
Part 7 Electronic Ballast Tester
LISUN GROUP
Electronic Ballast Tester (WT5000)
WT5000 has LCD for displaying waveforms and parameters directly.
Reports can be printed if printer is connected. It also meets the
latest requirements for electronic ballasts in international standards
IEC 60929, IEC 60969, IEC 61000-3-2.
Specification:
• WT5000 has expanding analysis for envelope wave
• Communicate the PC via RS-232, the English software can be run in Win7, Win8 and Win10
• Input Parameters Measurement:
1) Test voltage, current, power, power factor, power net frequency, total harmonic and 0~39 harmonic.
2) Range of voltage and current basic wave frequency:45Hz~65Hz:
3) Range of voltage: 10.0~300.0V (virtual value); Range of power: NR: 0~450.0W; WR: 0~999.9W
4) Range of current: NR: 0.010~1.500A (virtual value); WR: 0.010- 4.500A (virtual value)
5) Range of power factor: 0.000~1.000
• Output Stably Parameters Measurement:
1) Test lamp voltage, current, power, filament current, input cathodic current, crest factor, frequency
2) Range of lamp voltage: 10.0~300.0V; Range of lamp power: NR:0.5~200.0W, WR:0.5~400.0W
3) Range of lamp current, filament current, cathodic current: NR:0.010~0.750A; WR:0.010~1.500A
• Output Startup Parameters Measurement:
1) Test preheats time and lamp voltage, current, filament current, changing curve and data of input
cathodic current within 0 to 5s.
2) Range of lamp voltage: 10.0~800.0V; NR: 0.010~0.750A, WR: 0.010~1.500A
3) Range of lamp current, filament current and input cathodic current:
HID Ballast Tester (WT2000-HID)
Specification:
• Test voltage, current, power, power factor, power line frequency,
total harmonic and 0~50 harmonic
• Range of voltage and current basic wave frequency: 45Hz~65Hz;
• Range of narrow frequency: 45Hz~5kHz;
• Range of wide frequency: 45Hz~1MHz;
Electronic Ballast Automatic Test Equipment (ATE-1)
Specification:
Test series connection, parallel connection and series/parallel connections of the
electronic ballast (about 15 kinds of connections), available for various electronic
ballast.
• With a precise resistance box, tube is substituted for the resistance, can act as
many as 6 tubes. Resistance value: 1~4095Ω adjustable.
• Measure input parameters (vrms, irms, W, PF, harmonics, etc), output parameters
(on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory
frequency), can also test the ballast efficiency, abnormity protection, and power
symmetry of partial rectifier effect and etc.
• Program controlled AC power source to guarantee the smart choice of input
voltage and the frequency.
• Equipped with 17 inch LCD controlled machine, specially designed A/D combined
with special CPU, has the two left and right testing interfaces to achieve stability of
data and high-speed testing.
• Communicate the PC via RS-232, English software can be run in Win7 and Win10
30
Part 8 Electrical Safety Tester
LISUN GROUP
Glow-wire Test Apparatus (ZRS-3HS, ZRS-3H)
It is designed according to IEC60695-2-1, IEC60695-2-10, IEC60695-213 (GB/T5169.10-2006~GB/T5169.13-2006), < basic testing methods
of glow wire device> and UL 746A, IEC829, DIN695, VDE0471, the glow
wire tester ZRS-3H is suitable for resistance to abnormal heat and fire
test on lighting lamps, electronic products and household appliances.
Adopting high-temperature coating spraying on steel structure and
imported instrument display, with easy operation, stable performance.
The equipment is applicable to flame resistance tests of all levels of QC
departments and corresponding enterprises.
Note: The ZRS-3HS Gross weight is 50kg and package size 80*70*50cm
Compact Version
Specification:
• Thermocouple diameter: 1mm K type, import insulated thermocouple
which can endure high temperature, and it can endure about 1100℃
(superior to standard 1050℃)
• Heating temperature: adjustable continuously within the range of≤
500~1000℃, the accuracy of temperature is 1℃, the resolution of
temperature is ±3℃.
• Glowing time: 0.1~999.9s±0.1s (time range is adjustable).
• Burning time: 0.1~999.9s, auto record, manual pause.
• Flame chilling time: 0.1~999.9s, auto record, manual pause.
• Glow wire pressure on test specimen:1±0.2N. Limit pressure depth is
7mm.
• Glow wire: 80%Ni, 20%Cr and made in specific dimensions.
Touch Screen Version
Needle Flame Test (ZY-3S, ZY-3)
According to IEC60695-2-2 and IEC60695-11-5, ZY-3 Needle Flame
Test is applied in the production and quality control department of
lighting instrument, hyperpiesia electrical apparatus, domestic
appliance, machine electric appliance, electrical machine, power tool,
electronic instrument, electrician instrument and technical equipment.
Also, it is fit for the industry of insulation material, engineering
plastics and solid combustible material.
Note: The ZY-3S Gross weight is 50kg and package size 80*70*50cm
Compact Version
Specification:
Angle of burner: incline with 45°(when in test) / plumb(when adjust
the flame's height)
• Time of start burning: 0~999.9s±0.1s adjust (30s in general)
• Time of keep burning: 0~999.9s±0.1s, auto record, manual pause
• Height of flame: 12mm ± 1mm (test tool with height, adjustable)
• Burning air: 95% of butagas
• Test range of temperature: 0~1000℃
• Requirement of flame's temperature: within 23.5 seconds±1s when
the temperature rises from 100℃±2℃ to 700℃±3℃
• Temperature testing thermocouple: Φ0.5mm K pattern thermocouple
Touch Screen Version
31
Part 8 Electrical Safety Tester
LISUN GROUP
Horizontal Vertical Flame Tester (HVR-LSS, HVR-LS)
This equipment meets the requirements of ANSI/UL94, IEC60950-1, IEC6952-2 and GB. It is used to test the appliances and plastic materials parts of
electrical equipment for the horizontal, vertical flammability test. The product
tank shell is irony spray, and configured a transparent viewing window, the
digital meter shows the burning time, after flame time, afterglow time. This
device has beautiful appearance, is easy to use and has reliable performance.
Note: The HVR-LSS Gross weight is 50kg and package size 80*70*50cm
Specification:
• Burning Time: 0~999.9S(Adjustable), After flame Time: 0~999.9S
(Adjustable), After-blanch Time: 0~999.9S(Adjustable)
• Burning Angle: 0°, 20°, 45° and optional, Flame Height:
20mm~175mm (Adjustable)
• Gas Flow: 0.03~0.3ml/Min, Gas Pressure: 0~16Kpa pressure gauge
±200mm spout
• Burning Lamp: Internal tube diameter: 9.5±0.3mm,
Length:100mm±10mm
• Time Device: It can be accurate to 0.5S, Linear Measure: In millimeter
• Pressure Gauge: It can measure 0.2m water, taking 5mm as the
increment.
• Flow Meter: The maximum measurement accuracy is ±2%
• Position Adjustment: Sample clamp bracket can be up and down, left
and right controlled.
Compact Version
Touch Screen Version
Hot Wire Ignition tester (RSY-LT)
.Hot wire ignition tester is designed according to the standard requirement of IEC60695-2-20 and
GB4943, which meets Standard Test Method for Ignition of Materials by Hot Wire Sources. It is suitable
for electric and electronic products, household appliance materials to do ignition dangerous test. It
simulates the heat source or ignition source of simulates glow component and overload resistance which
may cause thermal stress in a short time
Hot-wire coil ignition test adopts the specific size (Dia: 0.5mm; Length: 250mm) and specific material
(Ni80/Cr20) of heater strip which is pre-annealed with required heating power (0.26W/mm) and
specified time (8s~12s). Then coil heater strip on the specimen for 5 cycles according to certain wire
wrapping tension (5.4N) and certain wire wrapping distance (6.35mm). Then take the specimen with
wrapping heater strip to test until 120s under the stipulate heating power (0.26W/mm). The users can
judge the fire risk according to the specimen ignite and the ignite time.
Specification:
• It is designed according to IEC60695-2-20 and GB4943
• Heating coil: ф0.5mm, Ni80/Cr20, Length: 250mm±5mm , Cold
Resistance: 5.28Ω/m , Anneal holder. Distance: 250mm
• Specimen holder distance and height: 70mm, Height: 60mm (The
distance from stand surface to the connector plate surface)
• Wire wrapping tension and its distance: 5.4N±0.05N, 6.3mm±0.2mm
(within 31.5mm±0.5mm, coil 5 cycle, national standard is 6mm)
• Annealing time and power: 8s~12s (Digital display can be preset).
0.26W/mm±4%(Digital displayis adjustable)
• Testing time and power 120s ( 1s~999.9s Digital display can be
preseted),0.26W/mm±4%(Digital display is adjustable)
• Specimen size:
L×W×H: (125±5)×(13.0±0.5)×(0.75+0.075)mm,1.5+0.150mm,3+0.3
0mm) national standard 0.75±0.1 mm, 1.5±0.1 mm, 3±0.2 mm
• Combustion box volume is bigger than 0.5 cubes(other sizes can be
optional)
32
Part 8 Electrical Safety Tester
LISUN GROUP
Tracking Test Chamber (TTC-1)
It fully meets IEC60695 and IEC60112 (Gb4207) and the Tracking Test Chamber TTC-1 is intended for
determining the degree of protection against formation of conducting paths in solid insulating materials,
due to the electric stress and electrolytic contamination of the surface. This method simulates tracking
currents on insulation material by providing drops between electrodes. During the process of normal use,
insulating material may be exposed to moisture and dirt, if conductive, may cause stress and fire hazard.
Specification:
• It applied with rectangle size of platinum electrode,
each electrode can force to the sample is 1.0±0.05N
• The testing voltage is 100~600V (48~60Hz) which
can be adjustable
• When the short-circuit current in the 1.0±0.1A, the
voltage drops will be no more than 10%
• During the testing, the short-circuit current is more
than 0.5 A to keep 2 seconds, then shut off current,
it will show the sample not pass
• The liquid drop device can make the liquid height
from 30~40mm (adjustable), drops liquid size is 44
~55 drops/1cm3. The interval drops of liquid is 30S
±5S (adjustable)
• Inside dimension: 800x800x800mm and outside
dimension: 1120x520x1250mm (Special size can be
ordered as customer's request)
Touch Screen Version
Temperature Meter for Lamp Caps & Luminaires Test (TMP-L)
TMP-L fully meets IEC60360-1998 and GB2512-2001 (Standard method of measurement of lamp cap
temperature rise). It is used to test the working and environmental temperature as well as temperaturerise of the burner and lamp. It meets the requirement of IEC and GB Standards
Specification:
• Channel sequence is displayed by 2 LED and temperature is
displayed by 4 LED; Simultaneously display temperature rise curve
• Sensor: K type thermocouple and 8 channels for input temperature
signal
• Temperature range: -40~300℃ and testing accuracy: Class 0.5
• Capable of circle monitoring, single monitoring, printing and RS-232
communication with PC
• Freely set up for channel sequence when circle monitoring
• Application software in Windows can track the changing of the
selected channel temperature and provide print and save operation
• Dimension of standard testing box: 90*90*90cm (inner box) and
105*105*120cm (outer box), or customized; Lamp holder: E14, E27,
E40, B22d and other holders
33
Part 8 Electrical Safety Tester
LISUN GROUP
Automatic Safety Test System (LS9955)
The LS9955/LS9956 Automatic Safety Test System fully
meets GB4706.1, IEC/EN60335-1, UL60335, GB7000,
IEC60598, GB4943, IEC60950 and GB9706.1 standard.
It is used for luminaries, home application and motor
tools safety test in production line or Lab R&D.
Specification:
• Include the handle to do remote operation
• Display all setting parameters and testing results in the same big LCD menu
• It can set the PASS/FAIL limit value. It has light/noisy to warn
• Test mode programmable; Quick discharge, 50 memory groups, 8 steps per group
• Support 50Hz and 60Hz frequency; Electric safety wall detecting feature
• The LS9955 can do test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current
(LLC) and Ground Resistance (GR)
• The LS9956 can do test for Withstand Voltage (AC/DC), Insulation Resistance (IR), Leakage Current
(LLC), Ground Resistance (GR) and Power
Withstand Voltage Test (AC/DC)
Insulation Resistance Test (IR)
Voltage Range
Accuracy
Current Range
100~4000V
±(5%+3V)
0.02~12.00mA
IR Range
0.50~500MΩ
Leakage Current Test (LLC)
LLC Range
0.01~20mA
Accuracy
Voltage Range
5%+0.5MΩ
DC100~1000V
Grounding Resistance Test (GR)
Accuracy
Voltage Range
GR Range
±(0.3%+5uA)
AC10.0~300.0V
0~600mΩ
Accuracy
±(5%+2mΩ)
Output Current
AC1.00~30.00A
Power Test
Voltage
Current
Power
PF
10.0~300.0V
0.010~20.00A
1.0~6000.0W
0.2~1.0
Accuracy
Test Time
Class 0.5
0~999.9s
Programmable Withstanding Voltage & Insulation Test (LS9923)
The LS9923 is a high-performance testing device special for
AC & DC Withstanding Voltage and Insulation Resistance Test,
It allows setting the output voltage. The warning value,
testing time and some other parameters can be set in the
screen. It has a variety of automatic test functions. The
testing is quick and high accuracy which is not only applied in
the production line but also in the lab developing research.
Output Voltage Range
Output Voltage Accuracy
Withstanding
Breakdown Current Range
Voltage
Insulation
Resistance
AC/DC Max 5.00KV
±(2%+3bits)
AC/DC: 0.10~12mA
Test time
0~999.9s
Output frequency
50Hz/60Hz
Output Voltage Range
DC Max 1.00KV
Output Voltage Accuracy
±(2%+3bits)
Insulation Resistance Range
1.0~2000MΩ
Insulation Resistance Accuracy
±(5% +3bits) <100 MΩ and ±(10% +5bits) >100 MΩ
Test time
0~999.9s
34
Part 9 Environmental Test Chamber
LISUN GROUP
High & Low Temperature and Humidity Chamber (GDJS-015A, GDJW-010A)
The High&Low Temperature and Humidity Chamber is designed according to the IEC60068-2-1. It fully meets
the test requirement of CFL/LED lamps , electricity products, electronic components, material ect.
Specification:
• The chamber is produced by SUS304 Steel, the Insulation
material is produced by Polyurethane hard foam and ultra
-fine fiber glass. Using double-deck aging silicone rubber door
sealing strip to insulate the high temperature steam.
• The controller is English and can communicate with PC.
• The temperature accuracy is 0.1℃ and humidity is 0.1%R.H
• The temperature sensor is PT100 Ohms/MV resistor
• The humidity sensor is Finland brand electronic hygrometer.
• The heating system is full separately system which produced
by Nickel chromium alloy electric heating type heater
• The cold system is applied by fully enclosed fan cooled single
-stage and cascade refrigeration mode, the compressor is from
France TECUMSEH brand which allow you get after sales
support from local country.
• Include the water pure system which allows you to connect
to your
• The cyclical system is applied by low noise motor and Multi
centrifugal wind wheel blade
• The self-protection function include Electric leakage,
short circuit, over temperature, motor overheating, compressor
pressure, overload, over-current protection and lack water
alarm
High & Low Temperature and Humidity Chamber with Programmable Function (GDJS Series)
Model (cm)
GDJS-225*
GDJS-500*
GDJS-010*
GDJS-013*
GDJS-015*
Workroom Dimensions
50*60*75
70*80*90
100*100*100
100*100*130
100*100*150
Exterior Dimensions
105*102*200
132*132*217
167*152*231
217*152*231
245*160*231
Work Power
7.0kW
13.5kW
15.0kW
16.5kW
16.5kW
Temperature Range
A: 20℃~150℃
Humidity Range
30%~98% R.H
Fluctuation/Evenness
±0.5℃/±2℃
B: 40℃~150℃
C: 60℃~150℃
2%~ 3% R.H
Humidity Deviation
Temperature Rise Speed 1.0~3.0℃/min
Temperature Fall Speed
0.7~1.0℃/min
High and Low Temperature Chamber with Programmable Function (GDJW Series)
Working Room Size
GDJW-225*
GDJW-500*
GDJW-010*
Workroom Dimensions (cm)
50x60x75
70x80x90
100x100x100 100x100x130
Temperature Range
A: -20℃~150℃
Fluctuation/Evenness
±0.5℃/±2℃
Temperature Rise Speed
1.0℃~3.0℃/min
Temperature Down Speed
0.7℃~1.0℃/min
B: -40℃~150℃
GDJW-013*
GDJW-015*
100x100x150
C: -60℃~150℃
The * in GDJS-225* means the temperature range A: -20℃~150℃, B: -40℃~150℃, C: -60℃~150℃
35
Part 9 Environmental Test Chamber
LISUN GROUP
Waterproof Test (JL-X)
JL-X waterproof test system is designed according to IEC60529, IEC60598, IEC60335 and IEC 60034-5
The JL-X includes the following test grades: IPX1, IPX2, IPX3, IPX4, IPX5, IPX6, IPX7 and IPX8 (Refer
to page 51 of IEC60529). It is widely used in the authentication test organization for the products
waterproof test such as electrical& electronic products.
JL-56
JL-34
The whole JL-X waterproof test system includes:
• Drip Box (JL-12): The drip box is for IPX1 and IPX2 drip test. The drip box size is 800x800x75mm
(LxWxH). The diameter of drip hole is 0.4mm, distant between each drip hole is 20mm, sample can be
over 150kg
• Swing Pipe Water Spray Test Equipment (JL-34): It is for IPX3 and IPX4 test, the semi-diameter of swing
pipe is 1meter. IPX3 is 120degree and IPX4 is 180degree. The diameter of inside swing pipe is 0.4mm.
The automatic sample rotating table’s diameter is 600mm and speed is 1~5rpm which be controlled by PLC panel
• Waterproof Jet Test Device (JL-56): With water supply device size is 1000x1000x600mm, the bore diameter
is ф6.3mm (IPX5) and ф12.5mm (IPX6). Diameter of hole is 6.3mm for IPX5 and 12.5mm for IPX6. The
water speed is 12.5±0.626L/min for IPX5 and 100±5L/min for IPX6.
• Immersion tank Waterproof test Device (JL-7): It is for IPX7 test. The top of the water tank size is 1000
x1000x1200mm. The sample testing base is max 120kg.
• Immersion tank Waterproof test Device (JL-8): It is for IPX8 test. It can measure 0~50m water depth.
The water immersion size is diameter is 600mm and height is 1200mm, the compressive stress is 10
atmospheric pressures or design customer request
36
Part 9 Environmental Test Chamber
LISUN GROUP
High Temperature & Pressure Jet Waterproof Test Chamber (JL-9K1L)
JL-9K1L High Temperature & Pressure Jet Waterproof Test Chamber is
designed according to IEC60529, GB4208, DIN40050-9 and ISO20653 for
protection level IPX9K testing. It is a waterproof test machine designed
for vehicle spare parts, electrical and electronic industry, to simulate
natural environment or human factors.
The both interior and exterior material of this chamber is high quality
stainless steel, big glass observation window and elegant appearance.
The turntable and spray lance motor adopt imported motor, rotation speed
can be adjusted according to requirement. .
Specification:
•
•
•
•
•
•
•
•
•
•
Working Chamber: 1000*1000*1000mm
Test time: 30s (Pre-settable and adjustable)
Angle of Water Ring: 0°, 30°, 60°,90°(The testing angle can be adjusted)
Number of blowhole: 4. Testing table: Load bearing 15kg/Φ400~500mm
Based on horizontal line, distribute nozzle hole at anticlockwise±0°±30°±60°±90°with valve on nozzle
Water Temperature in Tank: 80±5°(Adjustable, enhanced temperature and water overflow protection)
Spraying distance:100mm~200mm and can be adjustable nozzle distance by manual
Spraying pressure: 8000~10000kPa (81.5~101.9kg/cm2)
Electrical high temperature flow meter: Flow is 14~16 L/min
Rotation speed of testing table: 5~17r/min (Motor drives turbine slow rotating, control speed and
adjust to appropriate speed by frequency converter)
Aging and Life Test Rack (SY2036)
Specification:
• Input Power supply: AC220V, 50/60HZ, 12KVA Min (110V is option)
• Built-in transformer: 0-250V 5KVA and 0-300V 5KVA (Other power is option)
• Maximum power for EUT: 5KVA and 12A (Other power is option)
• EUT and Number: 112pcs B22, 112pcs E27. 36pcs T5/T8/T12 Tube. 32pcs LED panel (Other EUT can be
designed according to customer request)
• ON/OFF test: Can be set on the touch screen with program
• Test number: 0~99999(Adjustable)
The aging rack can be special designed according customer’s request
37
Part 9 Environmental Test Chamber
LISUN GROUP
Dustproof Testing Machine (SC-015)
The Dustproof Test Chamber SC-015 is designed according to IEC60529, GB2423.37-89 (Test L: dust test
methods), GB 4208-93 protective casing grade (IP code), GB/T 4942.2-93(protective casing grade of
low-voltage apparatus), GB 7000.1-1996, GB 7001-1986(protective casing grade of lamps), DIN40050 and
IP5K0. The SC-015 is applied in LED or other luminaries IP5X and IP6X test.
Specification:
•
•
•
•
•
Temperature Range: environmental temperature +5~50℃ (Adjustable)
Standard metal net line diameter: 50μm
Test dust: dry talcum powder, portland cement, smoke ash and etc.
Metal net diameter: 75μm
Dust selection: Use french chalk which can pass the metal net. Need
replace the dust after 20 times test. And add 2kg/m³ each time.
• Have a flow meter and press meter to adjust the flow meter of the vacuum
pump. Can run the IPX6 test.
• Power supply: 380V 3phases 50Hz/60Hz
Model Number
Working Room Size (mm)
SC-500
600*700*800
SC-800
800*800*800
SC-010
1000*1000*1000
SC-015
1000*1500*1000
SC-020
1000*2000*1000
Remark
Single door structure
Cabinet can be put in a horizontal direct or vertical direct
IK Level Tester (IK07-10)
Most of the luminaires manufactories are requested to do IK
level test (Impact Protection). LISUN can supply the IK test
instrument from IK01-10.
IK07-10 Impact Pendulum
IK ratings are defined as IKXX, where “XX” is a number from
00 to 10 indicating the degrees of protection provided by
enclosures (including luminaires) against external mechanical
impacts. The different IK ratings relate to the ability of an
enclosure to resist impact energy levels measured in joules (J).
IEC 62262 specifies how the enclosure must be mounted for
testing, the atmospheric conditions required, the quantity and
distribution of the test impacts and the impact hammer to
be used for each level of IK rating. The IK application on lighting
luminaires testing is according to IEC60598 (GB7000) and
IEC60068-2-75 (GB2423.55).
Degrees of protection against external mechanical impacts:
IK01
IK02 IK03 IK04 IK05 IK06 IK07 IK08 IK09 IK10
0.14J 0.2J
0.35J 0.5J
0.7J 1J
2J
5J
10J
20J
38
IK01-06 Spring Impact Hammber
Part 9 Environmental Test Chamber
LISUN GROUP
Salt Spray Test Machine (YWX/Q-010)
The Salt Spray Test Machine/Chamber is applicable to the salt spray corrosive test for the protection level
of components, parts, electronic and electrical parts and metal materials and industrial products.
Specification:
• The Salt Spray Test Machine is made of transparent
materials so that the operator can see the tested sample
in it and the spraying situation.
• A waterproof structure is adopted between the chamber
cover and chamber body, thus there is no salt spray
overflow.
• Can do continuous test and cycle test.
• It meets the following standards: IEC60068-2-11(GB/
T2423.17), GB/T10125, ISO9227, ASTM-B117, GB/
T2423-18, IEC 60068-2-52, ASTM-B368, MIL-STD-202,
E I A- 3 6 4 - 2 6 , A S T M - B 1 1 7 , GJB150, DIN50021-75,
ISO3768, 3769, 3770; CNS 3627, 3885, 4159, 7669 etc.
Model
Work Room Size (mm)
Exterior Size (mm)
Voltage
Power (kW)
YWX/Q-150
600*450*400
1100*750*930
1Phase/220V
2.5
YWX/Q-250
900*600*500
1500*900*1150
1Phase/220V
3.5
YWX/Q-750
1100*750*500
1700*1050*1150
1Phase/220V
4.5
YWX/Q-010
1200*800*500
1800*1100*1200
3Phase/380V
6.5
YWX/Q-016
1600*900*600
2300*1300*1300
3Phase/380V
9.5
YWX/Q-020
2000*1000*600
2700*1400*1500
3Phase/380V
11
Electrodynamic Vibration Generator System (LVD-100KG)
Electrodynamic Vibration Generator System is complied with IEC 60068, IEC68-2-6,
JJG189-97, GB/T13309-91, IEC60598 and GB2423 etc.
• LVD-100KG: Vibration table combined vertical table and horizontal table in one set
• LVD-100KG-6D: Vibration table combined vertical table and two directions horizontal
table in one set
Specification:
• Sine Wave, Frequency Modulation, Sweep Frequency,
Programmable, Frequency Doubling, Logarithm, High
Acceleration speed, Amplitude Modulation, Time Control,
Full function Computer Control, simple and easy to set
the acceleration and amplitude.
• Vibration table size: 500*500mm (Other size can be
designed)
• Vibration: 0~5mm (Adjustable range P-P). Vibration waveform:
sine wave (half wave and full wave). Acceleration speed: 0~20g (Adjustable)
• Maximum test load Capacity: 100kg
• Accuracy: Frequency can be displayed to 0.01 Hz. Precision 0.1 Hz
• Sweep Frequency function (1~600Hz): (Upper frequency, Lower frequency, Time range) It can set
real standard arbitrarily to sweep frequency back and forth
39
Part 9 Environmental Test Chamber
LISUN GROUP
UV Lamp Aging Chamber (UV-263LS)
UV lamp aging test Chamber is designed for evaluating the resistant performance of non-metallic
materials, organic materials (plastics, paints, coatings, rubbers, etc.) under the specified conditions such
as sunlight, temperature and other climatic conditions. The chamber fully complies with the requirements
of Standard ISO 4892-1, ISO 4892-3, ASTMG53 and etc.
Specification:
•
•
•
•
•
•
•
•
•
Temperature range: RT+40℃~70℃,Temperature uniformity: ±1℃
Temperature fluctuation: ±0.5℃, Humidity range: ≥90%RH
Irradiance is 1.0W/m2 (adjustable) and Effective area is 900×210mm
Temperature of irradiation blackboard: 50℃~70℃
Include 8pcs UVA lamps: L=1200mm, 40W and life ≥2000hrs
Sink depth: 25mm and auto control
Testing time: 0~999H(adjustable)
Distance between lamps is 70mm, sample to lamp is 50±3mm
Standard sample size: 75*290mm, Standard sample holder: 24 inches
Xenon Lamp Aging Test Chamber (XD-80LS)
Xenon lamp aging test Chamber adopts xenon arc lamp which can imitate the full spectrum of
sunlight to reappear destructive spectral wave that exists in different environment. It is
designed according to standard ISO 4892-1, ISO 4892-2, GB/T16585-1996, GB14522-93,
GB/T16422.3-97, D2565 ASTM D2565 and etc.
Specification:
•
•
•
•
•
•
•
•
•
•
Working Room size: 400*400*500mm (W*D*H)
Temperature range is 0℃~80℃ with tolerance is ±2℃
Humidity range is 30~98% with tolerance is 2.5%
The air cooling type long arc xenon lamp with full solar spectrum
Xenon lamp wavelength: 290~800nm, Power: 1.8kW, Life: 1600 hours
Raining Time is 1~9999min & Raining Cycle is 1~240min (adjustable)
The distance between the lamp center and the sample: 350~380mm
Sample rotation speed: 1r/min
Water Spray time: 0~99h59min (adjustable)
Refrigeration mode: mechanical refrigeration air cooling
Automatic Double Drop Test Machine (DT-60KG)
This series drop test bench for measuring the main simulation packages
in the transportation, loading and unloading process under drop impact
influence, identification package impact strength and packaging design.
Specification:
•
•
•
•
•
•
•
The drop height is 400~1500mm and motor rotation for height
The max weight test is 60kg and max size is 2000*800*300mm
Drop angle tolerance is <1° and drop height tolerance is ±10mm
Drop method: face, edge and corner
Power supply: AC380V/50HZ and 4KVA
The machine height display by the digital measuring instrument, also combined with calibration function
Drop method: Electromagnetic drive drop control, click on the drop button can be achieved the drop test
40
Part 10 AC and DC Power Supply
LISUN GROUP
Digital CC and CV DC Power Supply (DC3005)
Specification:
The DC Series Power Supplies are with high
stability and high accuracy. The voltage and
current can be adjustable and simple operation.
They are suitable to supply DC Power for the
standard lamp and the large power LED. Other
voltage and current DC Power Supply can be
designed according to customer's request.
DC3010
DC6005
Model
DC3005
DC6010
DC12005
Output Voltage Range
Output Current Range
0.005~30.00V 0.005~30.00V 0.005~60.00V 0.005~60.00V 0.0010~120V
0.005~5.000A 0.005~10.00A 0.005~5.000A 0.005~10.00A 0.005~5.00A
Voltage
0~30V, 0~60V or 0~120V
Resolution of Voltmeter
0.0001V(0.1V~10.000V) 0.001V(10.000V~60.000V)
Accuracy of Voltage and
Current
+/-(0.02% Reading + 0.01% Range +1 Digit)
Stability of Output Voltage
+/-0.01% Reading/3min
Stability of Output Current
+/-0.01% Reading/3min
AC Power Source (LSP-500VAR)
Specification:
•
•
•
•
•
•
•
•
•
•
•
•
AC-DC-AC frequency conversion technology
Output frequency range: 45.00~65.00Hz
Output voltage range: AC 0.0~300.0V
Zero output impedance, equivalent resistance ≤0.1
Insulation for power output to make test safely and steady
Protection for over hot and thundering voltage and current
Input by keyboard, big/small adjustment, fast parameter set-up
Total voltage distortion: ≤0.6%; Voltage stability: ≤0.1%/30 min
Load adjust rate: ≤0.1%; Frequency stability: ≤0.05%/30min
Digital wave synthesis, wave feed-back technology, low power distortion
Controlled and tested by 16 bits MCU, which has high automation
High speed 12 bits A/D sampling technology, exactly display Voltage,
Current, Power, Power factor, Frequency
Model
Output Power
LSP-500VAS
500W
0~150V: 4.2A, 150~300V: 2.1A
(LSP-500VAR is pure sine wave AC Power Source)
1000W
0~150V: 8.4A, 150~300V: 4.2A
(LSP-1KVAR is pure sine wave AC Power Source)
LSP-500VAR
LSP-1KVAS
LSP-1KVAR
Remark
All of AC Power Source can communicate with PC via Lisun software
41
Part 10 AC and DC Power Supply
LISUN GROUP
PWM Type AC Power Supply (LSP-5KVA)
Specification:
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation
• Input: 1 Phase 220V±10%, 50Hz/60Hz±5%
• Output Voltage: HIGH/LOW Adjustable
1) 1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V
2) Nominal Voltage: +10%~+25%, -10%~-30%
• Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz
• Load Voltage Stabilization Rate: ≦0.5%
• Frequency Stabilization Rate: 0.1% (Fix Point 50Hz, 60Hz and 400Hz)
• Wave Distortion Rate: ≦2% (Resistor Load); Efficiency:≧85%
• Output Instruments: Frequency Indicator, 4-digits RMS
digital frequency indicator, resolution is 0.1Hz Voltage Meter,
4-digits RMS digital voltage meter, resolution 0.1V Ampere
Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power
indicator, resolution 1W Power Factor Meter Resolution 0.001
• Over load, short circuit, over voltage, over current, over temperature protective with alarm
• Operating Environment: Temperature 0~40℃.Relative Humidity:0~90%
Model
Output Power
Specification
LSP-3KVA
3000W
0~150V: 25A, 150~300V: 12.5A
LSP-5KVA
5000W
0~150V: 42A, 150~300V: 21A
PS. More than 5KVA AC Power Source can be designed as customer’s request
Digital Power Meter (LS2008R, LS2010, LS2012, LS2050)
• Measure Voltage, Current, Power and Power Factor
• Voltage range: 10~600V; Current range: 0.005~20A
• Accuracy: ± (0.4%reading + 0.1%range + 1digit). LS2050: ±(0.1%reading+0.1%range+1digit)
• Communicate with PC by RS-232. It can communicate with LISUN other instruments such as LMS-7000,
LMS-9000 and LMS-9500
Model
Measure
Remark
LS2008R AC Parameters: U, I, P, PF
AC model
LS2010
AC Parameters: U, I, P, PF and harmonic
Special Software can show harmonic in Win7 or Win8
LS2012
AC+DC Parameters: U, I, P, PF
DC: 1~600V, DC Current Range: 0.005~20A (small
current 0.005~2A optional), out of limit alarming
LS2050
AC+DC Parameters: U, I, P, PF
and harmonic
High accuracy with Special Software can show
harmonic in Win7 or Win8, out of limit alarming
LS2010 Harmonic Model
LS2012 AC&DC Model
42
LS2050 High Accuracy Model
Lisun Instruments Limited
Http://www.Lisungroup.com
LISUN GROUP
Application
LED Luminaires and LED Power Driver Test Solution
Goniophotometer System: LSG-5000, LSG-1800B or LSG-1700B
Spectroradiometer & Integrating Sphere Test System: LPCE-2 or LPCE-3
LED Life Maintains Test System according to LM-80: LEDLM-80PL
Waterproof Test for IPX5 and IPX6 level testing: JL-56
Dustproof Testing Machine for IP5X and IP6X level testing: SC-015
LED Driver Testers: WT2080 (for LAB) and LEDLS-60 (for production line)
Electricity Safety Tester: LS9955, ZRS-3HS, ZY-3S
Single LEDs or LED Chips
CFL and Electronic Ballast Test Solution
Goniophotometer System: LSG-1800B or LSG-1700B
Integrating sphere and Spectrophotometer Test System: LPCE-2
Adjustable Reference Ballast: DYJ-50HZ, HCS-109A and DYJ-HID
Electric Ballast Tester: WT5000 (for LAB) and ATE-1 (for production line)
Digital Torsion Meter and Multiway Life Tester: CH338 and CH316
Electricity Safety Tester: LS9923, ZRS-3HS, ZY-3S
EMC and EMI Test Solution for CFL and LED Luminaires
EMI Test System: EMI-9KB or EMI-9KA
Electrostatic Discharge Simulator: ESD61000-2
EFT Immunity Measurement: EFT61000-4
Surge Generator: SG61000-5
Voltage Dips and Interruptions Generator: CSS61000-11
Ring Wave Generator: RWG61000-12
LED Luminaires
LED Power Driver
Certificate & Awards
CIE Supportive Membership
CE-EMC Certificate
CE-LVD Certificate
ISO9001:2008
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project