EL-WiFi-21CFR-DTP+ VACCINE

EL-WiFi-21CFR-DTP+ VACCINE
EL-WiFi-21CFR-DTP+ VACCINE
High Accuracy 21CFR Remote WiFi Temperature Sensor
Dual Channel External Thermistor with Glycol Bottle
• Can be installed as part of a 21CFR compliant system with additional
controls including permission-based use, authority level sign-off and
full system audit
• -40°C to +125°C (-40°F to +257°F) temperature measurement range
• Dual channel recording through two glycol high accuracy
thermistor probes
• Wirelessly stream and view data on the EasyLog™ 21CFR Cloud
• Configurable high and low alarms with indicator
The EL-WiFi-21CFR-DTP+ VACCINE measures the temperature of the
environment in which the two probes are situated. Data is streamed
wirelessly over any compatible WiFi network to be viewed on the
EasyLog 21CFR Cloud. During configuration, the sensor will search for
an existing wireless network whilst physically connected to the PC. It can
then be placed anywhere within range of the network. If the sensor
temporarily loses connectivity with the network, it will log readings until
it is able to communicate again with the EasyLog 21CFR Cloud (max 30 days
at 10-second sample interval). The unit is freestanding, but can be attached
to a wall or surface using the bracket provided.
The sensor is IEEE 802.11bgn (2.4GHz) compliant, supports WEP, WPA/WPA2
encryption and enterprise networks (PEAP, TTLS, FAST).
SPECIFICATIONS
ACCESSORIES
Minimum
Battery life
USB supply voltage
Typical
Maximum
>6
4.5
5
Vdc
+60 (+140)
°C (°F)
-20 (-4)
Logging period (user configurable)
10 sec
10 min
12 hrs
Transmission period (user configurable)
1 min
1 hr
24 hrs
Temperature measurement resolution
Temperature display resolution
Temperature accuracy
Dimensions
-40 (-40)
+125 (+257)
0.01 (0.02)
°C (°F)
°C (°F)
0.01
±0.2/±0.4
±0.6/ ±1.2
(-15 to +80/ (-40 to +125/
+5 to +158) -40 to +257)




Data records cannot be edited or deleted
Complete system audit trail
PSU USB-UK
USB Mains Power
Adapter for UK
PSU USB-EU
USB Mains Power
Adapter for EU
INCLUDED IN THE BOX
°C/°F
21CFR COMPLIANCE
Authority based action sign-off
USB Mains Power
Adapter for USA
EL-WIFI WALL BRACKET
82 x 70 x 36mm (3.22 x 2.75 x 1.41”)
Permission based use and access
PSU-5VDC-USB-USA
Months
5.5
Operating temperature range
Temperature measurement range (probe)
Unit
Wall mounting
bracket for EL-WiFi
sensors
2x EL-PROBEA-3.0M-TP-GLY External Thermistor
Glycol Probe
CABLE USB A-MICRO B
USB Type A to Micro B
CABLE SPLITTER
Dual Probe Y Splitter
Cable
For a detailed compliance checklist, please visit www.lascarelectronics.com/data-brochures
1.800.561.8187
www.
.com
[email protected]
EL-WiFi-21CFR-DTP+ VACCINE
High Accuracy 21CFR Remote WiFi Temperature Sensor
Dual Channel External Thermistor with Glycol Bottle
21CFR WIFI SENSOR SOFTWARE
EasyLog 21CFR WiFi software* is available as a free download from www.easylogcloud.com.
Easy to install and use, EasyLog 21CFR WiFi Sensor Software allows easy sensor set-up and
connection of sensors to a WiFi network and the EasyLog 21CFR Cloud.
EASYLOG 21CFR CLOUD
21CFR Cloud subscription delivers all of the flexibility of a remote monitoring system:
Interact with sensors via any internet-enabled device; manage and monitor sensors;
access event logs and set up email alerts; assign authorisation levels to user accounts and
view comprehensive audit trail records. Unlike the standard EasyLog Cloud service, 21CFR Cloud includes other controls such as
permission-based use, authority sign-off and full system audit to ensure data monitored and collected is regulated to 21CFR Part
11 standard.
Detailed data reporting
Detailed system audit reporting
Authority sign-off on actions
A Cloud account subscription is created during the WiFi sensor set-up process using EasyLog 21CFR WiFi Sensor Software. 21CFR
WiFi Sensors are only compatible with the 21CFR Cloud www.easylogcloud.com
Download the latest version of the software free of charge from www.easylogcloud.com
BATTERY LIFE AND POWER SUPPLY
The battery can be recharged (unit must be between 0 - 40 °C) via a PC, a USB +5V wall adapter, or a portable USB battery
pack using the USB lead provided. It can also be permanently powered by a USB wall adapter or USB battery pack. Readings
may be affected while the internal battery is being charged. However, once charged, continued connection of the charger will
have no effect.
Battery life is dependent on: transmission period, WiFi encryption method, WiFi encryption key rotation frequency (determined
by the router/access point), signal strength between router/access point and WiFi device, presence volume and type of WiFi
traffic from other devices, sample rate and operating temperature.
Specifications liable to change without prior warning
*Requires Windows 7, 8.1, 10
1.800.561.8187
www.
.com
[email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project