Peerless LCC 18, LCC 18-S, LCC 36, LCC 36-S ceiling mount Installation instructions
Below you will find brief information for ceiling mount LCC 18, ceiling mount LCC 18-S, ceiling mount LCC 36, ceiling mount LCC 36-S. These ceiling mounts are compatible with LCD screens up to 29 inches and offer various features to ensure safe and secure mounting. The mounts can be adjusted in height, tilt, and swivel to achieve the desired viewing angle. They also come with security fasteners for theft prevention and support both portrait and landscape orientations. The included ceiling plate can be mounted to wood or concrete, and hardware is provided for both applications. The mounts are VESA 75/100 mm compliant and are UL Listed, ensuring safety and reliability.
Advertisement
Advertisement
Installation and Assembly:
Ceiling mount for LCD screens up to 29"
Models: LCC 18, LCC 18-S, LCC 36, LCC 36-S
Patent Pending
Features:
• Comes in two adjustable height ranges (in 1" increments): 18"-30" and
36"-48"
• -5° to +20° adjustable tilt
• Screen can be mounted in standard position or face-down
• Portrait or landscape orientation
• Ceiling plate included
• Hardware included for wood or concrete installations
• Theft resistant security fasteners included
• VESA
®
75/100 mm compliant (Non-VESA adapter offered separately)
• Comes in black and silver
• 360° swivel action
R
This product is UL Listed. It must be installed by a qualified professional installer.
Max Load Capacity: 40 lb (18.1 kg)
3215 W. North Ave. • Melrose Park, IL 60160 • (800) 729-0307 or (708) 865-8870 • Fax: (708) 865-2941 • www.peerlessindustries.com
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Note: Read entire instruction sheet before you start installation and assembly.
WARNING
• Do not begin to install your Peerless product until you have read and understood the instructions and warnings contained in this Installation Sheet. If you have any questions regarding any of the instructions or warnings, please call Peerless customer service at 1-800-729-0307.
• This product should only be installed by a qualified professional.
• Make sure that the ceiling will safely support the combined load of the equipment and all attached hardware and components.
• Never exceed the Maximum Load Capacity of 40 lb (18.1 kg).
• If mounting to wood ceiling joists, make sure that mounting screws are anchored into the center of the joists. Use of an "edge to edge" stud finder is highly recommended.
• Always use an assistant or mechanical lifting equipment to safely lift and position equipment.
• Tighten screws firmly, but do not overtighten. Overtightening can damage the items, greatly reducing their holding power.
Accessories
•
Lightweight Adjustable Suspended Ceiling Kit (CMJ 500)
•
Lightweight Suspended Ceiling Kit (CMJ 455)
•
Accessory Pack for CMJ 455 (ACC 455)
•
Lightweight Cathedral Ceiling Plate (ACC 912)
•
Unistrut or Structural Ceiling Plates (CMJ 300, CMJ 310)
•
Anti-Vibration Ceiling Plates (ACC 845)
•
I-Beam Clamps (ACC 558, ACC 559)
•
Truss Ceiling Adapter (ACC 557)
•
Unistrut Adapter (ACC 550)
•
Escutcheon Ring (ACC 640)
•
Round Ceiling Plate (ACC 570)
•
Cord Wrap (ACC 852(W)(S))
•
3/4" Pipe Reducer (ACC 913)
•
Fixed Length 1 1/2" Extension Columns
(EXT models)
•
Adjustable Length 1 1/2" Extension Columns
(ADJ models)
•
Extension Column Stabilizer Kit (ACC 050)
•
Extension Column Connector (ACC 109)
•
1/2" Threaded Rod (ACC 820)
•
Threaded Rod Adapter (ACC 810)
•
Non-VESA Adapter Plates (LC models)
Tools Needed for Assembly
• stud finder ("edge to edge" stud finder is recommended)
• phillips screwdriver
• drill with 1/4", 3/8", and 5/32" drill bits
Table of Contents
Parts List .............................................................................................................................................................................. 3
Installation to Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings ............................................ 4
Installation to Concrete Ceilings ........................................................................................................................................... 5
Installing Reducer ................................................................................................................................................................ 6
Flush Mount Installation ....................................................................................................................................................... 7
Installation to Threaded Rod ................................................................................................................................................ 7
Installation to Extension Column .......................................................................................................................................... 8
Installation to Lightweight Suspended Ceiling Plate ............................................................................................................. 9
Attaching Tilt Bracket to LCD Screen ................................................................................................................................. 10
Installation of Plasma in the Vertical Position ..................................................................................................................... 11
Installation of Plasma in the Horizontal Position ................................................................................................................. 12
For customer service call (800) 729-0307 or (708) 865-8870.
2 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Parts List
Description
A
tube assembly
B
ceiling plate
C
tilt bracket
D
reducer
E
#14 x 2.5" wood screw
F
M5 x 12 mm socket pin screw
2 5S1-015-C03 5S1-015-C04 5S1-015-C03 5S1-015-C04
4 520-1064 520-2064 520-1064 520-2064
G
4 mm security allen wrench
H
Alligator® concrete anchor
I
10-32 x 3/8" socket set screw
J
hex wrench
1 560-9646
2 590-0097
1 520-1127
1 560-1034
K
M4 x 10 mm socket pin screw 4 520-1060
L
M4 x 12 mm serrated washer head socket pin screw 4 510-1079
M
M4 x 20 mm socket pin screw
N
#10-32 x 3/16" slotted set screw
4
1
520-1061
520-1187
O
retaining spacer
P
M5 x 10 mm socket pin F-type screw
Q
cable tie
LCC 18
Qty. Part #
1
1
1
1
055-1520
580-1042
055-1551
580-1009
4 590-5005
1 520-1164
3 590-1168
LCC 18-S
Part #
055-4520
580-4042
055-4551
580-4009
560-9646
590-0097
500-2018
560-1034
520-2060
510-2079
520-2163
520-2187
590-5003
520-2031
590-1168
LCC 36
Part #
055-1521
580-1042
055-1551
580-1009
560-9646
590-0097
520-1127
560-1034
520-1060
510-1079
520-1061
520-1187
590-5005
520-1164
590-1168
LCC 36-S
Part #
055-4521
580-4042
055-4551
580-4009
560-9646
590-0097
500-2018
560-1034
520-2060
510-2079
520-2163
520-2187
590-5003
520-2031
590-1168
A B C
D
G
E
M
H
F
O
3 of 12
I
N
J
K
L
P
Q
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Installation to Wood Joist Finished Ceilings,
Exposed Wood Joists, or Wood Beam Ceilings
Drill two 5/32" (4 mm) dia. holes to a minimum depth of 2.5" (64 mm). Attach ceiling plate (B) with two #14 x 2.5" (6 mm x 65 mm) wood screws (E) as shown using 3/8" (10 mm) socket wrench. Tighten wood screws (E) so ceiling plate (B) is firmly attached.
WARNING
• Tighten wood screws so that ceiling plate is firmly attached, but do not overtighten. Overtightening can damage the screws, greatly reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the joist. The use of an "edge to edge" stud finder is highly recommended.
Skip to step 2 on page 6.
WOOD
JOIST
CEILING
B
E
E
4 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Installation to Concrete Ceilings
Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach ceiling plate (B) using two concrete anchors (H) and #14 x 2.5" wood screws (E) as shown in Illustration A and 1, 2, and 3 (below).
Tighten all fasteners.
WARNING
• Tighten wood screws firmly, but do not overtighten.
Overtightening can damage the bolt, greatly reducing its holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Concrete anchors are not intended for attachment to concrete wall covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete wall covered with plaster/drywall is unavoidable, plaster/drywall (up to 5/8" thick) must be counterbored as shown below. If plaster/drywall is thicker than 5/8", custom fasteners must be supplied by installer.
metal bracket
INCORRECT
concrete metal bracket
CORRECT
concrete plaster/ dry wall plaster/ dry wall
B
CONCRETE
CEILING
H
E
Illustration A
1
concrete ceiling
H
Drill hole and insert anchor
2
B
E
H
Place ceiling plate over anchor and secure with screw
3
E
H
After repeating step one tighten all fasteners
5 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Installing Reducer
Thread reducer (D) onto tube assembly (A) until tight.
Insert set screw (I) into reducer as shown in figure 2-1.
Tighten screw using hex wrench (J). Note: Set screw
(I) is used to jam against the threads of tube assembly to prevent any excess movement.
D
figure 2-1
I
A
6 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Flush Mount Installation
Screw reducer (D) into ceiling plate (B) until notch in reducer is aligned with one of the four holes in ceiling plate and set screw (I) is at least partially covered by ceiling plate as shown in figure 3-1.
Secure reducer with one M5 x 10 mm F-type socket pin screw (P) using security allen wrench (G) as shown in figure 3-2. Note: Slotted set screw (N) is used to jam against the threads of the reducer to prevent any excess movement of the tube assembly (A). Do not overtighten screw; overtightening screw will damage threads making it difficult to separate the products.
Skip to step 4 on page 10.
B
D
N
P
Installation to
Threaded Rod
Accessory ACC 810, threaded rod adapter, is required. Not UL Listed.
Screw threaded rod adapter (ACC 810) into extension column connector (ACC 109). Align slot in threaded rod adapter with one of the top holes in extension column connector. Insert and tighten one #10-32 x 3/
8" socket pin screw provided with extension column connector through extension column connector into slot on threaded rod adapter using 4 mm security allen wrench (G). See figure 3-3.
Align slot in reducer (D) to one of the bottom holes in extension column connector. Insert and tighten one
#10-32 x 3/8" socket pin screw provided with extension column connector through extension column connector into slot in reducer. See figure 3-4.
Note: Slotted set screws provided with extension column connector are used to jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it difficult to separate the products.
Skip to step 4 on page 10.
7 of 12
I
figure 3-1
A
figure 3-2
1/2 -13 THREADED
ROD
ACC 810 (SOLD
SEPARATELY)
SET
SCREW
THREADED
ROD
ACC 810
SLOT
SLOT
ACC 109
(SOLD
SEPARATELY)
ACC 109
SOCKET
PIN
SCREW
figure 3-3
THREADED
ROD
SLOT
D
ACC 109
SET
SCREW
ACC 810
D
SLOT
SOCKET
PIN
SCREW
figure 3-4
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Installation to Extension Column
Screw extension column (EXT or ADJ
Series) to ceiling plate (B). Align the notch with one of the four holes in the ceiling plate and secure extension column with a M5 x 10 mm socket pin screw (P) using security allen wrench
(G). See figure 3-5.
Note: Slotted set screw (N) is used to jam against the threads of the reducer to prevent any excess movement of the extension column. Do not overtighten screw; overtightening screw will damage threads making it difficult to separate the products.
B
EXTENSION
COLUMN
(UL Listed EXT or
ADJ Series)
Sold Separately
Screw extension column connector (ACC
109) to extension column. Align slot in extension column with one of the top holes in extension column connector.
Insert and tighten one #10-32 x 3/8" socket pin screw provided with projector through extension column connector into slot on extension column using security allen wrench (G). See figure 3-6.
Screw reducer (D) to extension column connector. Align reducer to one of the bottom holes in extension column connector. Insert and tighten one #10-32 x 3/8" socket pin screw provided with connector through extension column connector into slot in reducer using security allen wrench (G). See figure 3-7.
SLOT
SLOT
P
EXTENSION
COLUMN
EXTENSION
COLUMN
CONNECTOR
(SOLD
SEPARATELY)
SET SCREW
ACC 109
D
Note: Slotted set screws provided with extension column connector are used to jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it difficult to separate the products.
ACC 109
Skip to step 4 on page 10.
figure 3-5 figure 3-6
N
B
EXTENSION
COLUMN
SLOT
SOCKET PIN
SCREW
EXTENSION
COLUMN
SLOT
SET SCREW
B
SOCKET PIN
SCREW
ACC 850 - EXTENSION COLUMN
CONNECTOR WITH CORD MANAGEMENT
- MAY BE USED IN PLACE OF EXTENSION
COLUMN CONNECTOR. (SOLD
SEPARATELY)
8 of 12
figure 3-7
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Installation to Lightweight Suspended Ceiling Plate
Refer to instruction sheet for lightweight suspended ceiling plate (CMJ 455) for attachment of ceiling plate to ceiling.
Screw extension column (EXT or ADJ
Series) to
retaining collar in ceiling tray
.
Align the notch with one of the four holes in retaining collar and secure extension column with one M5 x 10 mm socket pin screw (P) using security allen wrench (G). See figure 3-8.
Note: Slotted set screw (N) is used to jam against the threads of the reducer to prevent any excess movement of the extension column. Do not overtighten screw; overtightening screw will damage threads making it difficult to separate the products.
Screw extension column connector to extension column. Align slot in extension column with one of the top holes in extension column connector.
Insert and tighten one 10-32 x 3/8 socket pin screw provided with connector through extension column connector into slot on extension column using security allen wrench. See figure
3-9.
Screw reducer (D) to extension column connector. Align slot in reducer to one of the bottom holes in extension column connector. Insert and tighten one 10-32 x 3/8 socket pin screw provided with connector through extension column connector into slot in reducer using security allen wrench. See figure 3-10.
Note: Slotted set screws provided with extension column connector are used to jam against the threads of each connecting joint to prevent any excess movement. Do not overtighten screws; overtightening screws will damage threads making it difficult to separate the products.
LIGHTWEIGHT
SUSPENDED
CEILING PLATE
(SOLD SEPARATELY)
EXTENSION
COLUMN
(UL Listed EXT or
ADJ Series)
Sold Separately
EXTENSION
COLUMN
CONNECTOR
(SOLD
SEPARATELY)
SLOT
N
EXTENSION
COLUMN (SOLD
SEPARATELY)
figure 3-8
EXTENSION
COLUMN
SET SCREW
ACC 109
RETAINING COLLAR
P
SOCKET PIN
SCREW
figure 3-9
SLOT
SLOT
D
ACC 109
SET SCREW
EXTENSION
COLUMN
D
SOCKET PIN
SCREW
ACC 850 - EXTENSION COLUMN
CONNECTOR WITH CORD
MANAGEMENT - MAY BE USED IN PLACE
OF EXTENSION COLUMN CONNECTOR.
(SOLD SEPARATELY)
9 of 12
figure 3-10
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Attaching Tilt Bracket to LCD Screen
Note: This product is designed to accommodate screens with VESA
®
compliant hole patterns. For safe mounting, please make sure that mounting screws turn at least three complete turns in the screen inserts.
FOR VESA 75 MOUNTING PATTERN:
1) Choose hole pattern indicated below. 2) Attach tilt bracket (C) to back of screen using four M4 x 10 mm screws
(K) as indicated below. 3) If hole pattern is in a pocket, attach tilt bracket to back of screen using four M4 x 20 mm screws (M) and four retaining spacers (O) as indicated below. Tighten all security screws with security allen wrench (G).
C
BOTTOM OF SCREEN
For screens with a hole
pattern in a pocket, spacers (O) go between tilting bracket (C) and screen.
Note: LCD screen may appear slightly different than illustrated.
FOR VESA 100 MOUNTING PATTERN:
1) Choose hole pattern indicated below. 2) Attach tilt bracket (C) to back of screen using four M4 x 10 mm screws
(K) as indicated below. Tighten all security screws with security allen wrench (G).
Note: If installing LCD screen model Sharp
®
LC-13E1U, LC-15E1U, LC-20E1U, or if you don't get three complete turns in the screen inserts, use four M4 x 12 mm screws (L) instead of four M4 x 10 mm screws (K).
C
BOTTOM OF SCREEN
Note: LCD screen may appear slightly different than illustrated.
10 of 12
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Installation of Screen in the Vertical Position
Insert two M5 x 12 mm screws (F) into column bracket of tube assembly (A) (see figure 5-1). Leave approximately
3/16" of thread exposed (see figure 5.2).
COLUMN
BRACKET
3/16"
EXPOSED
THREAD
F fig. 5-1 fig. 5-2
Hook tilt bracket (C) onto column bracket (see figure 6-1). Secure with two M5 screws (F) (see figure 6-2). Adjust tilt
(20° forward and 5° back) and swivel to desired position. Tighten all screws using security allen wrench (G).
Note: Cable ties (Q) are provided for optional cord management along tube.
WARNING
• Always use an assistant or mechanical lifting equipment to safely lift and position the LCD screen.
fig. 6-1
C
COLUMN
BRACKET
F
11 of 12 fig. 6-2
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05
Installation of Screen in the Horizontal Position
Insert two M5 x 12 mm screws (F) into column bracket of tube assembly (A) (see figure 5-1). Leave approximately
3/16" of thread exposed (see figure 5-2).
COLUMN
BRACKET
3/16"
EXPOSED
THREAD
F fig. 5-1 fig. 5-2
Hook tilt bracket (C) onto column bracket (see figure 6-1). Secure with two M5 screws (F) (see figure 6-2). Adjust tilt
(20° forward and 5° back) and swivel to desired position. Tighten all screws using security allen wrench (G).
Note: Cable ties (Q) are provided for optional cord management along tube.
WARNING
• Always use an assistant or mechanical lifting equipment to safely lift and position the LCD screen.
F
COLUMN
BRACKET
C fig. 6-1
12 of 12
© 2004 Peerless Industries, Inc. All rights reserved.
Peerless is a registered trademark of Peerless Industries, Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners.
fig. 6-2
ISSUED: 09-27-04 SHEET #: 100-9004-2 01-19-05

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Adjustable height
- Tilt and swivel
- VESA 75/100 mm compliant
- Security fasteners
- UL Listed
- Comes in black and silver