Industrial Serial Fiber Converter Preliminary IFC-FDC-PRO PROFIBUS to Daisy Chain Fiber Converter IFC-Serial-PRO PROFIBUS to Fiber Converter EN61000-6-2 EN61000-6-4 PROFIBUS These products are PROFIBUS to fiber optic converters which secure PROFIBUS data transmission via fiber optical cabling for extending distance and isolating EMC/noise to reduce mutual interference between PROFIBUS devices. These products are protocol transparent, can be applied to the PROFIBUS, and also can be applied to other networks using RS485 interfaces (See Figure 1). Features ▪▪Supports 2 fiber link (IFC-FDC-PRO) ▪▪Supports 1 fiber link (IFC-Serial-PRO) ▪▪Extend serial transmission distance up to 2km, 30km, 60km ▪▪Supports several topology , cable redundancy (Figure 3), ring redundancy (Figure 4), daisy chain (Figure 5), point to point (IFC-FDC-PRO) ▪▪Supports point to point (Figure 6) (IFC-Serial-PRO) ▪▪Redundant dual power inputs (12/24/48VDC) ▪▪Protocol transparent. These products can be applied to the PROFIBUS, but also can be applied to other network using RS485 interface ▪▪Baudrate up to 12Mbps ▪▪Auto baudrate, no need to set baudrate ▪▪2.5KVrms isolation for serial port ▪▪CE, FCC, heavy industrial grade EMS, EMI, EN61000-6-2, EN61000-6-4 certified ▪▪Supports relay output for power or link failure warning ▪▪Hardened housing with IP30 protection ▪▪Fanless and DIN-Rail design for harsh industrial environment ▪▪Adjustable pull high/low resistor and terminator for RS-422/485 transmission Specifications FieldBus Protocol Problem isolation Fiber Port Interface Fiber port Topology Serial port Interface Protocol PROFIBUS and all operations available transparent on RS485 Isolate EMC/noise to reduce mutual interference between PROFIBUS device. Isolate the PROFIBUS side of the failure, to avoid the impact of the other side (See Figure 2 ) Connector SC, ST 2 fiber ports (IFC-FDC-PRO) Fiber Port 1 fiber port (IFC-Serial-PRO) MM 2km, SM 30km, 60km Fiber Type Bidi 20KM MM 1310nm, SM 1310 Wavelength Bidi: Mode A : TX1310nm/RX1550nm Mode B : TX1550nm/RX1310nm Point to Point Full duplex Transmission Ring Full duplex, self-healing operation Transmission Zero recovery time Cable redundancy(Figure 3) with zero recovery time Ring redundancy(Figure 4) with zero recovery time Daisy chain(Figure 5) Point to point (IFC-FDC-PRO) Point to point(Figure 6) (IFC-Serial-PRO) DB9 Female Serial Port Connector RS-485 : 4, 2 wires RS-485 direction Automatically detection Serial port 50 to 12Mbps Baudrate Auto baudrate, no need to set baudrate Serial port 2.5KVrms isolation for serial signals isolation EMC/noise isolation, to reduce mutual interference between serial port device Serial port Interface Pull high resistor Pull low resistor 120 ohm terminator Environmental Operating Temperature Selected by 10 position rotary switch Selected by 10 position rotary switch Built-in 120 ohm terminator (Selected by Dip Switch) -10 ~ 60°C (IFC-FDC-PRO, IFC-Serial-PRO) -40 ~ 75°C (IFC-FDC-PRO-E, IFC-Serial-PRO-E) Storage -40 ~ 85°C Temperature Humidity 5 ~ 95% RH LED Indications PWR1, PWR2, Alarm, Master, TD, RD, Fiber Link, Fiber2 Link (IFC-FDC-PRO only), Ring Alarm Relay Alarm exists for power, fiber link or ring protection Relay output with carry capacity 1A @ 24VDC Power Redundant Dual Power 12, 24, 48 VDC Power Input (9.6 ~ 60VDC) Power <6W Consumption Power Reversal Yes Protection Over Current Protection: Signal Short Together Protected Terminal Block for Power and Alarm : Terminal Block : V1+, V1-, V2+, V2-, Alarm NC, Alarm COM, Alarm NO Mechanical Water & Dust IP30 Protection, Fanless Proof Dimensions 106 x 38.6 x 142.1mm (D x W x H) Mounting DIN-Rail, or wall mounting (Optional) Weight TBD www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. 8-1 8 Industrial Serial Fiber Converter These converters are capable of selecting interface modes for connection to RS-485 2-wire half duplex or 4-wire full duplex. Additionally, the terminal block offers an alarm relay contact and two redundant DC power inputs. IFC Series converters are also available in two operating temperature ranges, a standard -10° to 60°C commercial temperature range and an extended -40° to 75°C range. With all these specifically designed features, the series is reliable and an ideal solution for keeping your industrial automation applications running smoothly and continuously even in harsh environments. Industrial Serial Fiber Converter Certification EMC EMI Immunity for Heavy Industrial Environment Emission for Heavy Industrial Environment EMS EN61000-4-2 ESD Level 3 EN61000-4-3 RS Level 3 EN61000-4-4 EFT Level 3 EN61000-4-5 Surge Level 3 EN61000-4-6 CS Level 3 IEC 60068-2-32 IEC 60068-2-6 IEC 60068-2-27 RoHS TBD (Electromagnetic Susceptibility) Protection Level CE FCC Part 15 Subpart B Class A, CE EN61000-6-2 Free Fall Vibration Shock Green MTBF EN61000-6-4 Application & Topology (IFC-FDC-PRO) Figure 1 : Application for PROFIBUS Network 0004 12 0004 12 5F 5F PLC Sensor HMI Digital power meters PROFIBUS PROFIBUS Digital power meters HMI Sensor PLC Fiber PROFIBUS 0004 12 IFC-FDC-PRO 5F PLC Sensor HMI Digital power meters PROFIBUS IFC-FDC-PRO Fiber Ring 5F Digital power meters IFC-FDC-PRO Benefit: 0004 12 1. EMC/noise isolation, to reduce mutual interference between serial port device 2. Extend distance by fiber 3. Cable redundancy 4. Isolate PROFIBUS failure 5. Achieve a reliable network environment HMI Sensor PLC IFC-FDC-PRO IFC-FDC-PRO PROFIBUS 0004 12 5F Digital power meters HMI Sensor PLC Figure 2 : Isolate PROFIBUS Failure Failure 5F PLC HMI Fiber Cable PROFIBUS 0004 12 PROFIBUS 0004 12 5F Digital power meters IFC-FDC-PRO IFC-FDC-PRO Digital power meters HMI PLC Figure 3 : Fiber Cable Redundancy topology & application Fiber Cable Redundant RS485 RS485 IFC-FDC-PRO IFC-FDC-PRO Figure 4 : Fiber Ring Redundancy topology & application IFC-FDC-PRO IFC-FDC-PRO RS485 RS485 Master Fiber Fiber Ring RS485 IFC-FDC-PRO IFC-FDC-PRO IFC-FDC-PRO RS485 8-2 RS485 www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. Industrial Serial Fiber Converter Figure 5 : Fiber Daisy Chain topology & application IFC-FDC-PRO IFC-FDC-PRO IFC-FDC-PRO Fiber Fiber RS485 IFC-FDC-PRO RS485 Fiber RS485 RS485 Application & Topology (IFC-Serial-PRO) Figure 6 : IFC-Serial-PRO Application for PROFIBUS 8 HMI PLC Industrial Serial Fiber Converter Digital power meters 0004 12 IFC-Serial-PRO Digital power meters PROFIBUS 0004 12 5F IFC-Serial-PRO PROFIBUS Fiber 5F IFC-Serial-PRO Fiber IFC-Serial-PRO Digital power meters 0004 12 PROFIBUS IFC-Serial-PRO IFC-Serial-PRO Fiber 5F PROFIBUS 0004 12 5F Digital power meters HMI PLC Figure 7 : Fiber Point to Point topology & application Fiber RS485 IFC-Serial-PRO RS485 IFC-Serial-PRO Benefit: 1. Reduce mutual interference between serial port device 2. Extend distance by fiber 3. Achieve a reliable network environment www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. 8-3 Industrial Serial Fiber Converter Ordering Information Serial (ProfiBus) Model Name Fiber RS422/485 Isolation 2.5KV SC/ST IFC-FDC-PRO 1 V IFC-FDC-PRO-E 1 V IFC-Serial-PRO 1 IFC-Serial-PRO-E 1 Power Input Certification Redundant EN61000-6-2 EN61000-6-4 CE FCC 2 12/24/48VDC V V V 2 12/24/48VDC V V V V 1 12/24/48VDC V V V V 1 12/24/48VDC V V V E SC002 Operating Temperature -10~60°C -40~75°C -10~60°C -40~75°C Model Naming Rule Industrial Serial Fiber Converter Connector Type SC, ST PRO FDC IFC FDC : IFC-FDC Serial: IFC-Serial PRO: PROFIBUS E: -40~75 C Blank: -10~60 C Connectivity Distance 002: M/M 2km 030: S/M 30km 060: S/M 60km 020AB: 20KM Bidi (20KM 1x mode A + 1x Mode B) (for IFC-FDC-PRO) 020A: 20KM Bidi mode A (for IFC-Serial-PRO) 020B: 20KM Bidi mode B (for IFC-Serial-PRO) Mode A: TX 1310nm/RX1550nm Mode B: TX 1550nm/RX1310nm Temperature Example: Package List • One device of the series • Quickly installation guide • Din Rail with screws • Terminal block Optional Accessories Wall Mount kit Accessories IND-WMK01 8-4 See below for more detail Wall Mount kit for Industrial product, 184 x 30mm www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. Connector Connectivity Type Distance IFC – FDC –PRO– □ – □□□□□ IFC – FDC –PRO – E– SC002 Industrial Serial Fiber Converter Preliminary IFC-Serial-CAN CAN BUS to Fiber Converter EN61000-6-2 EN61000-6-4 PROFIBUS These products are CAN BUS to fiber optic converters which secure CAN BUS data transmission via fiber optic to extend distance and isolate from EMC/noise thus reducing interference between CAN BUS devices. (See Figure 1) The converters are available in two operating temperature ranges, a standard -10° to 60°C commercial temperature range and an extended -40° to 75°C range. With all these specifically designed features, the series is reliable and an ideal solution for keeping your industrial automation applications running smoothly and continuously even in harsh environments. Features 8 Specifications FieldBus Protocol Problem isolation System Propagation delay Fiber Port Interface CAN 2.0A, CAN 2.0B, ISO 11898-2 standard Isolate EMC/noise to reduce mutual interference between CAN BUS device. Isolate the CAN BUS side of the failure, to avoid the impact of the other side (See Figure 2) 125ns Connector Fiber Port Fiber Type Wavelength Baud rate Fiber port Topology CAN BUS port interface Power SC, ST 1 fiber port MM 2km, SM 30km Bidi 20KM MM 1310nm, SM 1310nm Bidi: Mode A : TX1310nm/RX1550nm Mode B : TX1550nm/RX1310nm Upto 1Mbps Auto baud rate, depend on CAN BUS copper port Point to point (Figure 3) 3 pin terminal block CAN_L, CAN_H, CAN_GND 50 to 1Mbps Baudrate Auto baudrate, no need to set baudrate CAN BUS port 2.5KVrms isolation for CAN BUS isolation signals EMC/noise isolation, to reduce mutual interference between serial port device 120 ohm Built-in 120 ohm terminator (Selected terminator by Dip Switch) Environmental Operating -10 ~ 60°C (IFC-Serial-CAN) Temperature -40 ~ 75°C (IFC-Serial-CAN-E) Storage -40 ~ 85°C Temperature Humidity 5 ~ 95% RH LED Indications PWR1, PWR2, Alarm, Fiber TX, Fiber RX Alarm Relay Alarm exists for power, fiber link Relay output with carry capacity 1A @ 24VDC Mechanical Certification EMC EMI Immunity for Heavy Industrial Environment Emission for Heavy Industrial Environment EMS (Electromagnetic Susceptibility) Protection Level Free Fall Vibration Shock Green MTBF Power Input Redundant Dual Power 12, 24, 48 VDC (9.6 ~ 60VDC) Power <3W Consumption Power Reversal Supported for power input Protection Over Current Protection : Signal Short Together Protected Terminal Block for Power and Alarm : Terminal Block : V1+, V1-, V2+, V2-, Alarm NC, Alarm COM, Alarm NO Water & Dust IP30 Protection, Fanless Proof Dimensions 106 x 38.6 x 142.1mm (D x W x H) Mounting DIN-Rail, or wall mounting (Optional) Weight TBD CE FCC Part 15 Subpart B Class A, CE EN61000-6-2 EN61000-6-4 EN61000-4-2 ESD Level 3 EN61000-4-3 RS Level 3 EN61000-4-4 EFT Level 3 EN61000-4-5 Surge Level 3 EN61000-4-6 CS Level 3 IEC 60068-2-32 IEC 60068-2-6 IEC 60068-2-27 RoHS TBD www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. 8-5 Industrial Serial Fiber Converter ▪▪Subbports protocol CAN 2.0A , CAN 2.0B, ISO 11898-2 standard ▪▪Extend serial transmission distance up to 2km, 30km ▪▪Redundant dual power inputs (12/24/48VDC) ▪▪Baudrate up to 1Mbps ▪▪Auto baudrate, no need to set baudrate ▪▪2.5KVrms isolation for CAN BUS port ▪▪CE, FCC, heavy industrial grade EMS, EMI, EN61000-6-2, EN61000-6-4 certified ▪▪Supports relay output for power or link failure warning ▪▪Hardened housing with IP30 protection ▪▪Fanless and DIN-Rail design for harsh industrial environment ▪▪120 ohm terminator selectable by DIP SW Industrial Serial Fiber Converter Application & Topology Figure 1 : IFC-Serial-CAN Application for CAN BUS Dashboard IFC-Serial-CAN CAN BUS Fiber CAN BUS Sensor 80 IFC-Serial-CAN Dashboard PLC (CAN Device) 80 IFC-Serial-CAN Fiber IFC-Serial-CAN IFC-Serial-CAN Dashboard IFC-Serial-CAN Fiber CAN BUS 80 Dashboard CAN BUS Benefit: PLC (CAN Device) Sensor 80 1. EMC/noise isolation, to reduce mutual interference between copper port device 2. Extend distance by fiber 3. Isolate CAN BUS failure 4. Achieve a reliable network environment Figure 2 : Isolate CANBUS Failure Failure CAN BUS Fiber Cable CAN BUS 80 Sensor Dashboard 80 PLC PLC (CAN Device) (CAN Device) IFC-Serial-CAN Dashboard Sensor IFC-Serial-CAN Figure 3 : Fiber Point to Point topology Fiber CAN BUS IFC-Serial-CAN Benefit: 1. Reduce mutual interference between serial port device 2. Extend distance by fiber 3. Achieve a reliable network environment 8-6 www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. CAN BUS IFC-Serial-CAN Industrial Serial Fiber Converter Ordering Information Serial Model Name Fiber CAN BUS Isolation 2.5KV SC/ST IFC-Serial-CAN 1 V IFC-Serial-CAN-E 1 V Power Input Certification Operating Temperature Redundant EN61000-6-2 EN61000-6-4 CE FCC 1 12/24/48VDC V V V 1 12/24/48VDC V V V -10~60°C -40~75°C Temperature Connector Connectivity Type Distance Model Naming Rule IFC Industrial Serial Fiber Converter Connector Type SC, ST Serial Serial: IFC-Serial CAN E CAN: CAN BUS E: -40~75°C Blank: -10~60°C SC002 See below for more detail Connectivity Distance 002: M/M 2km 030: S/M 30km 020A: 20KM Bidi mode A 020B: 20KM Bidi mode B Mode A: TX 1310nm/RX1550nm Mode B: TX 1550nm/RX1310nm Example: IFC – Serial –CAN– □ – □□□□□ IFC – Serial – CAN – E– SC002 Package List 8 • Din Rail with screws • Terminal block Industrial Serial Fiber Converter • IFC-Serial-CAN device • Quickly installation guide Optional Accessories Wall Mount kit Accessories IND-WMK01 Wall Mount kit for Industrial product, 184 x 30mm www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. 8-7 Industrial Serial Fiber Converter IFC-FDC RS-232/422/485 Daisy Chain Fiber Converter IFC-Serial RS-232/422/485 Fiber Converter UL60950-1 EN61000-6-2 EN61000-6-4 PROFIBUS These converters are capable of selecting interface modes for connection to RS-232 (3 wire), RS-485 (2 wire, half duplex) or RS-422/485 (4 wire, full duplex) and feature a three-way communication plus a second independent RS-232 communication channel. Additionally, the terminal block offers an alarm relay contact and two redundant DC power inputs. IFC Series converters are also available in two operating temperature ranges, a standard -10° to 60°C commercial temperature range and an extended -40° to 75°C range. With all these specifically designed features, IFC Series are reliable and ideal solutions for keeping your industrial automation applications running smoothly and continuously even in harsh environments. The product is protocol transparent that can be applied to RS485/422/232 networks, such as MODBUS to achieve reliable network (See Figure 2). Features ▪▪Supports 2 fiber link (IFC-FDC) ▪▪Supports 1 fiber link (IFC-Serial) ▪▪Supports dual channel communication, including Triple-Way communication, and Two-Way communication ▪▪Extend serial transmission distance up to 2km, 30km, 60km ▪▪Supports several topology , cable redundancy (Figure 3), ring redundancy (Figure 4), daisy chain (Figure 5), point to point (IFC-FDC) ▪▪Supports point to point (Figure 7) (IFC-Serial) ▪▪Redundant dual power inputs (12/24/48VDC) ▪▪Protocol transparent, suitable for all serial (RS485/422/232) transmission protocol, such as Modbus... ▪▪Baudrate up to 1024kpbs for serial port ▪▪Auto baudrate, no need to set baudrate ▪▪2.5KV isolation for serial port (RS485/422/232) ▪▪UL60950-1, CE, FCC, heavy industrial grade EMS, EMI, EN61000-6-2, EN61000-6-4 certified ▪▪Supports relay output for power or link failure warning ▪▪Hardened housing with IP30 protection ▪▪Fanless and DIN-Rail design for harsh industrial environment ▪▪Adjustable pull high/low resistor and terminator for RS-422/485 transmission Specifications FieldBus Protocol Data Flow Optical Interface Fiber port Topology Electrical Interface 8-8 Protocol applicable to all operations available on RS485/422/232, such as Modbus,… Dual Channel Both of Triple-Way and Two-Way Communication Communication Way (Figure 1 or 6) Connector SC, ST 2 fiber ports (IFC-FDC) Fiber Port 1 fiber port (IFC-Serial) MM 2km, SM 30km, 60km Fiber Type Bidi 20KM MM 1310nm, SM 1310 Wavelength Bidi: Mode A : TX1310nm/RX1550nm Mode B : TX1550nm/RX1310nm Point to Point Full duplex Transmission Ring Full duplex, self-healing operation Transmission Protocol transparent Cable redundancy(Figure 3), ring redundancy(Figure 4), daisy chain(Figure 5), point to point (IFC-FDC) Point to point(Figure 7) (IFC-Serial) RS-232(DB9), RS-422/RS-485(5 pin Serial Port terminal block) Connector RS-485 : 4, 2 wires, RS-422 : 4 wires RS-485 direction Automatically detection Serial port 50 to 1024kpbs Baudrate Auto baudrate, no need to set baudrate Serial port 2.5KV isolation for serial signals isolation EMC/noise isolation, to reduce mutual interference between serial port device Pull high resistor Selected by 10 position rotary switch Pull low resistor Selected by 10 position rotary switch 120 ohm Built-in 120 ohm terminator (Selected terminator by Dip Switch) Environmental Operating -10 ~ 60°C (IFC-FDC, IFC-Serial) Temperature -40 ~ 75°C (IFC-FDC-E, IFC-Serial-E) Storage -40 ~ 85°C Temperature Humidity 5 ~ 95% RH LED Indications PWR1, PWR2, Alarm, Master, TD, RD, Fiber Link, Fiber2 Link (IFC-FDC only), Ring Alarm Relay Alarm exists for power, fiber link or ring protection Relay output with carry capacity 1A @ 24VDC Power Redundant Dual Power 12, 24, 48 VDC Power Input (9.6 ~ 58VDC) Power 6W (IFC-FDC) Consumption 5W (IFC-Serial) Power Reversal Yes Protection Over Current Protection : Signal Short Together Protected Terminal Block for Power and Alarm : Terminal Block : V1+, V1-, V2+, V2-, Alarm NC, Alarm COM, Alarm NO Mechanical Water & Dust IP30 Protection, Fanless Proof Dimensions 106 x 38.6 x 142.1mm (D x W x H) Mounting DIN-Rail, or wall mounting (Optional) Weight 0.64kg (IFC-FDC) 0.63kg (IFC-Serial) Certification Safety UL60950-1 EMC CE EMI FCC Part 15 Subpart B Class A, CE Immunity for Heavy Industrial EN61000-6-2 Environment Emission for Heavy Industrial EN61000-6-4 Environment www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. Industrial Serial Fiber Converter Certification Certification EMS EN61000-4-2 ESD Level 3 (Electromagnetic EN61000-4-3 RS Level 3 Susceptibility) EN61000-4-4 EFT Level 3 Protection Level EN61000-4-5 Surge Level 3 EN61000-4-6 CS Level 3 Free Fall Vibration Shock Green IEC 60068-2-32 IEC 60068-2-6 IEC 60068-2-27 RoHS 739,886 Hours (IFC-FDC) 847,029 Hours (IFC-Serial) (MIL-HDBK-217) MTBF Application & Topology (IFC-FDC) Figure 1 : Dual Channel Data Flow Channel 1 : Triple Way Channel 2 : Two Way Isolation Terminal Block RS-422/485 TX/RX CH 1 TX/RX Fiber1/2 Logic DB9 CH 2 8 RS-232 1 TX/RX Industrial Serial Fiber Converter SG common RS-232 2 TX/RX Figure 2 : Application for Modbus Network 0004 12 0004 12 5F PLC Sensor HMI Modbus RTU Digital power meters Modbus RTU Digital power meters HMI Sensor PLC Fiber Master IFC-FDC IFC-FDC Modbus RTU 0004 12 5F Fiber Ring Modbus RTU Message Server 5F Digital power meters IFC-FDC HMI Sensor PLC IFC-FDC IFC-FDC Benefit: Modbus RTU 1. EMC/noise isolation, to reduce mutual interference between serial port device 5 2. Extend distance by fiber Digital 3. Cable redundancy power meters 4. Achieve a reliable network environment 0004 12 F HMI Sensor PLC Figure 3 : Fiber Cable Redundancy topology & application Fiber Cable Redundant RS485/422/232 RS485/422/232 IFC-FDC IFC-FDC www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. 8-9 Industrial Serial Fiber Converter Figure 4 : Fiber Ring Redundancy topology & application IFC-FDC IFC-FDC RS-232/422/485 RS-232/422/485 Fiber Master Fiber Ring RS-232/422/485 RS-232/422/485 IFC-FDC IFC-FDC IFC-FDC RS-232/422/485 Figure 5 : Fiber Daisy Chain topology & application IFC-FDC IFC-FDC IFC-FDC IFC-FDC RS-232/422/485 Fiber Fiber Fiber OPC Server RS-232/422/485 RS-232/422/485 RS-232/422/485 RS-232/422/485 Application & Topology (IFC-Serial) Figure 6 : Dual Channel Data Flow Isolation Channel 1 : Triple Way Channel 2 : Two Way Terminal Block RS-422/485 TX/RX CH 1 TX/RX Fiber Logic CH 2 DB9 RS-232 1 TX/RX SG common RS-232 2 TX/RX Figure 7 : Fiber Point to Point topology & application Fiber RS485/422/232 IFC-Serial Benefit: 1. Reduce mutual interference between serial port device 2. Extend distance by fiber 3. Achieve a reliable network environment 8-10 www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. RS485/422/232 IFC-Serial Industrial Serial Fiber Converter Dimensions IFC-FDC 45.72 30.00 38.60 106.00 15.20 29.45 9.00 184.00 50.53 142.10 30.02 30.00 51.30 4.10 12.00 Side View Front View Rear View DIN-Rail Kit View 8 Wall-Mount Kit View (Optional accessory) 45.72 30.00 38.60 106.00 Industrial Serial Fiber Converter IFC-Serial 15.20 29.45 9.00 184.00 50.53 142.10 30.02 30.00 25.40 4.10 12.00 Side View Front View Rear View DIN-Rail Kit View Wall-Mount Kit View (Optional accessory) Ordering Information Model Name Dual Channel Serial (ModBus or others) RS232 RS422/485 Fiber Isolation 2.5KV SC/ST Power Input Daisy Chain Redundant Certification Safety UL60950-1 EN61000-6-2 EN61000-6-4 CE FCC IFC-FDC V 2 1 V 2 V 12/24/48VDC V V V V IFC-FDC-E V 2 1 V 2 V 12/24/48VDC V V V V IFC-Serial IFC-Serial-E V 2 1 V 1 12/24/48VDC V V V V V 2 1 V 1 12/24/48VDC V V V V Operating Temperature -10~60°C -40~75°C -10~60°C -40~75°C Model Naming Rule Industrial Serial Fiber Converter Connector Type SC, ST E FDC IFC FDC : IFC-FDC Serial: IFC-Serial E: -40~75°C Blank: -10~60°C SC002 See below for more detail Connectivity Distance 002: M/M 2km 030: S/M 30km 050: S/M 50km 020AB: 20KM Bidi (20KM 1x mode A + 1x Mode B) (for IFC-FDC ) 020A: 20KM Bidi mode A (for IFC-Serial ) 020B: 20KM Bidi mode B (for IFC-Serial ) Mode A: TX 1310nm/RX1550nm Mode B: TX 1550nm/RX1310nm Example: IFC – FDC – □ – □□□□□ IFC – FDC – E – SC002 Optional Accessories Package List • One device of the series • Quickly installation guide Connector Connectivity Temperature Type Distance • Din Rail with screws • Terminal block Wall Mount kit Accessories IND-WMK01 Wall Mount kit for Industrial product, 184 x 30mm www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. 8-11 Ethernet Serial Server STE100A-232 RS232 Serial Server STE100A-Serial RS485/232 Serial Server The IP Device Server provides the serial device server for hosts to control RS-232, 2 or 4 wire asynchronous RS-422/485 serial devices located virtually anywhere through a TCP/IP or UDP/IP connection. The Device Server has the DB9 port connection on one side, and a 10/100 Mbps Ethernet connection on the other side. It connects serial devices such as PLC, alarm sensors and PTZ camera control to IP networks. Applications include industrial/factory automation, public safety and surveillance systems. The IP Device Server Windows driver is designed to control the IP Serial Server devices. The driver installs a virtual COM on Windows which maps the virtual COM port to the IP address of the IP Serial Server device across the network, enabling the Windows applications to access remote serial devices over Ethernet. IP Device Server can function as a UDP or a server or client for TCP connection. The application scenarios are direct IP mode, virtual COM mode, and paired mode. Features ▪▪10/100Mbps Ethernet port ▪▪230.4kbps serial interface ▪▪TCP Server, TCP client, Virtual com mode, UDP ▪▪Supports for DHCP, HTTP, ICMP, ARP, IP, UDP, TCP ▪▪Support Virtual COM ▪▪Easy to use with Windows utility ▪▪2 Wire(half duplex) or 4 Wire(full duplex)RS-422/485(STE100A-Serial) ▪▪Configurable IEEE 802.3 DA/SA assignment ▪▪Flexible RS-232/422/485 Interface (STE100A-Serial) ▪▪Configuration by web browser ▪▪Low power consumption with 12VDC input ▪▪Wall mount , or Din Rail optional Specifications General LED OS supported Serial Interface Serial Connector Baudrate Data bits Stop bits Parity Flow Control Data Packing Delimiter LAN Interface Communication Modes Ready, TP Link/Act, Data TX/RX Windows XP / 2000 / 2003 / 2008 / VISTA / WIN7 / WIN8 STE100A-Seria l : RS-232/422/485 STE100A-232 : RS-232 DB9 Male 110 to 230.4Kbps 5, 6, 7, 8 1, 1,5 for Data bits 5 mode; 1, 2 for data bits 6, 7, 8 mode None, Even, Odd None or RTS / CTS for RS-232 Full Duplex(4-Wire) or Half Duplex(2-Wire) for RS-422/485 1, 2 Protocols Management Security Power Operating Temperature Storage Temperature Humidity DIN rail mount Panel mount Dimensions TCP, UDP, IP, ARP, ICMP, HTTP, DHCP Web pages, Firmware upgrade Password Access 12VDC external switching power adapter 0 ~ 60°C -10 ~ 70°C 0 – 90% non-condensing DIN-Rail Mounting Kit (Optional) Yes 85.8 x 84.2 x 22mm (D x W x H) with DIN-Rail Mounting Kit CE, FCC 2,501,030 Hours (STE100A-232) 2,385,346 Hours (STE100A-Serial) (MIL-HDBK-217) Certifications MTBF RJ-45 connector, IEEE802.3 10/100Base-TX TCP Server, TCP Client, Virtual COM mode, UDP Application STE100A-Serial STE100A-Serial 0004 12 5F Sensor PLC 0004 12 RS-232/422/485 Digital power meters 10/100Base-T Ethernet UDP, TCP Server 5F RS-232/422/485 Digital power meters UDP, TCP Client Remote Host PLC Sensor Local Host IP Network Ethernet STE100A-Serial 0004 12 RS-485 2 Wire 5F Digital power meters HMI PLC Relay Output Sensor 8-12 www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. Ethernet Serial Server Appearance STE100A-232 STE100A-Serial Power input 12 to 48VDC Power input 12 to 48VDC Load Default/Reset Button Load Default/Reset Button Ethernet RJ45 10/100Mbps Ethernet RJ45 10/100Mbps 8 Ethernet Serial Server RS-232 RS-232/422/485 Dimensions STE100A-232 STE100A-Serial Unit: mm (inch) RS-232 RS-232/422/485 RS-232/422/485 Ordering Information Model Name STE100A-232 STE100A-Serial Description 1-port RS232 device server with AC power adapter 1-port RS232/422/485 device server with AC power adapter Package List • One device of the series • CD (VCOM, Manual) • 12V DC Switching power adapter • Rubber Foot Optional Accessories Terminal & Wall Mount Kit STE100A-Serial-WT STE100A-Serial DB9 wiring terminal STE100A/DRK01 STE100A/RS232,STE100A/Serial DIN-Rail Mounting Kit Industrial Power Supply DC-APT/12V DB9 Wiring Terminal -48VDC to 12VDC Adapter - 0.83 Amp, 10 Watts , Output 12 VDC, Input -48VDC STE100A-Serial-WT (only for STE100A-Serial) Din-Rail Mounting Kit STE100A/DRK01 www.ctcu.com / [email protected] Specifications & design are subject to change without prior notice. Please visit CTC Union website for more details. 8-13
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement