Untitled
Panasonic
AIR CONDITIONING and HEAT
PUMP PRODUCTS
GN VERTER
o] D)
September 2013
History of Air Conditioning Group
The Global Trusted Air Conditioning Brand
In the 55 years since its establishment, the Panasonic Air Conditioning Group has
grown into a global company.
Through its continuous quest for product innovations, the group has evolved from
manufacturing compressors to providing comprehensive Air Conditioning solutions.
This has earned Panasonic, the reputation as the most trusted brand for superior
quality and reliable products.
HISTORY
of Panasonic Air Conditioners
1958-2013
1958
1961
1965
1968
1972
1983
1985
1989
1990
1992
1993
1779
Started production and sales of Home Coolers gal a :
The Electrical Appliance Business Group (Kadomal — Ta -
started cooler production in March 1958. Started sales in И
May under the "Home Cooler” name. (e Hi Е
HCE DS
Started exports of Home Coolers
Launched Room Coolers
Began development of Rotary Compressors
Later, their high efficiency and high quality attracted
domestic and overseas air conditioner manufactures.
Began external sales.
Established overseas business base in Malaysia
MAICO was established in Malaysia as the Aircon
Group's first overseas base.
From this time, MAICO started to export to Japan,
Indonesia, Australia, and other markets. Panasonic
started operating a twin-base system with a presence
in Japan and Malaysia.
cs
Launched inverter Air Conditioner
Started sales of Panasonic's first inverter air conditioners and
has since ges increasing popularity. Inverter became the
future technology of air conditioner market.
Launched Ductless Air Conditioners to USA
Began development of Scroll Compressors
Began development of scroll compressors, offering high
efficiency, low noise, and low vibration in comparison to
rotary compressors.
Introduced Simultaneous Heat 8: Cool VRF
Launched world's first Compact Scroll Compressor-equipped
Air Conditioner
Developed industry s smallest outdoor air conditioning
unit: Chi-size”
Established Matsushita-Wanbao (Guangzhou) Air Conditioner [MWAC)
Established Matsushita-Wanbao (GuangzhoulCompressor [MWCC]
Established Matsushita Air Conditioner Engineering [Matsushita ACE]
Started the export of VRF
1998 | Introduced GAS Heater Air Conditioner 14KGS11
2001 | Introduced first VRF "ECO-Multi” to USA
2003
2005
2006
2008
2009
2011
2013
Launched first R410a refrigerant Ductless A/C to USA
Launched EcoCute as a result of better
energy-saving technology
Launched accumulator-less, high-efficiency,
CO; scroll compressor for EcoCute
Began production of Multi-split packaged
air conditioner [mini-VRF]
Launched air conditioner =
automatic filter cleaning я & =
function [AC robot) т E
Product became extremely successful in the Japanese
market. Since then, Panasonic launched a series of innovative
products such as airstream robots and motion sensors which
significantly improved Panasonic's air conditioner market share.
Renewed ECO-Multi to ECO-i. revised the line-up to
inverter driven
Aggregated global production of
Panasonic compressors reached 200 million units
In 2008 Energy Conservation Grand Prizes,
EcoCute won its first Director General Prize of Agency
of Natural Resources and Energy,
while Panasonic air conditioner won
the Chairman Prize of the Energy
Conservation Center of Japan Started Air
to Water heat pump business in Europe
Established air conditioner dedicated sales company
in Europe (PHAAE)
Panasonic HA Air-Conditioning Europe [PHAAE]
strengthened the commercial air conditioning business.
Integration of Sanyo HVAC USA into
Panasonic Corporation of North America.
Serving the US
Ductless market
since 1983
Celebrating the 30th
anniversary of marketing
in the USA,
Technological Topics
1998
2001
2003
2013
Introduced revolutionary Gas Heater
Air Conditioner 14KGS11.
That maintains a consistent heating
performance level, regardless of how
much the ambient temperature goes
down outside.
Launched VRF "Eco-Multi™
to the US market.
Eco-Multi was displayed at the AHR
show, and was introduced to other
ductless manufacturers. It's the new
Individual air-conditioning system that
effectively combines a power control
compressor and an electronic
refrigerant control valve.
First R410a driven ductless model,
24KS62R, was introduced.
Again, blazed a trail to other ductless
manufacturers.
Introduce EXTERIOS series to US
market
SEER 28.5 Highest Efficient model in
Industry as of 2013/March
Air Conditioners and Heat Pumps Lineup
|=
=
re
Las]
| =
==
| === 1]
вл
[=
pres
=
со
нЕ
|
3
Q
=
a
Ee
La]
[mb]
|
Panasonic: Your Best Choice in Ductless Split Air Conditioning and Heat Pump Systems
Panasonic's Ductless Split Air Conditioner and Heat Pump products offer a wide range of versatile
solutions for cooling and heating requirements for single or multiple rooms.
The Indoor unit (evaporator) is mounted inside the room. Enclosed in a handsome space saving
cabinet, it is connected to the outdoor unit [condenser] via refrigerant lines and inter-unit wiring
through a 3-1/2" opening in the wall. Since no ductwork is required, installation is simple, fast and
efficient.
The indoor unit has been uniquely designed to provide whisper quiet operation while delivering comfort
throughout the room (s).
Panasonic Ductless Split Systems bring together sleek styling in wall, duct or ceiling mounted
systems, with whisper-quiet operations, quality and reliability you can count on.
Since the launch of Ductless Split in 1983, after 30 years of renovation and experience,
Panasonic is adding new Deluxe Wall Mount EXTERIOS” series, the most highly efficient in the
ductless industry, in the product lineup. Again, Panasonic is moving forward, leaving the others behind.
HEAT PUMP MODELS
Btu/h 9,000 17,000 18,000 24,000 | 26,000 30,000 36,000 42,000
MODEL XE9PKUA XE12PKUA, ET2NKUA ET8NKUA 26PENTU6, 24PETIUS KE36NKU, 36PET1U6 AZPETIUG
(System) EONKUA KE12NB41 KE18NB4U EZ4NKUA 24PEUUS, 24PEFTUG KESONKU 36PEUTU6, 36PEFIU6 42PEUTUG
| NEW EE
EEE — - —
Wall = =
vous | MB ®
CS-XEPKUA CS-XEY2PKUA
CU-XESPKUA CU-XE12PKUA
e | e e o o
CS-ENKUAW CS-El2NKUAW CS-ETBNKUA CS-EZCHKUA CS-KE3ONKU CS-KEZ6NKU
A CU-ESNKUA CU-E12NKUA CU-E18NKUA CU-EZANKUA CU-KEJONKU CU-KE6NKU
> - -
— (=; Wall — =
5/51 Mounted a |
e 3 S-26PK1U6
= suspend
3 S-26PTIU6 5-36PTIU6 S-42PTIUS
Ceiting AN CN JE” à 1 E
Recessed > \ EN =. | e
CS-KE12NB41 CS-KE1SNBAUW 5-26PU1U6 S-36PU1U6 S-42PU1U6
Concealed 009
Duet
S-26PFIU6 S-24PFIUS
" e e e ss.
CU-KE12NK1 CU-KE18NKU PEI IPE | U-42PEIÚS
COOLING ONLY MODELS / STANDARD TYPE
Btu/h 9,000 12,000 18,000 22,000
MODEL S18NKU-1, KS18NKU
2| (System) Mu STZNKU-1 KS18HBAU S22NKU-1
=
EE E = > E ——
© = Wall = = = =
iH > г ® ©
= CS-SINKUW-1 CU-SPNKU-1 CS-STZNKUW-1 CU-S1ZNKU-1 CS-SIONKU-1 CU-STANKU-1 CS-S22NKU-1 CU-S2NKU-1
*Please refer to the model code on the back of this catalog.
COOLING ONLY MODELS / LOW AMBIENT TYPE
MODEL a SIZNKUA - STBNKUA ER 26PSKIU6, 26PSTIVG naa: KSI6NKUA, 36PSTI0 42ZPSTIVE
(System) а KS1ZNB41A KSTONB4UA SUNKUA | epsunuezepsriue | KSSONKUA | g4pSUIUG,34PSFIUG | __42PSUTUG =
} — as ———————;—] OO = mi 5
Wal = = = = E
| © o o o o o. >
CS-SYNKUA CS-SIZNKUA CS-STBNKUA CS-S24NKUA CS-KS30NKU CS-KS36NKU =
CU-S9NKUA CU-S12NKUA CU-STBNKUA CU-S26NKUA CU-KS30NKUA CU-KS36HKUA e
Wal _— === =
Mounted — =
S-26PK1U6
a
К == Suspended
E = S-26PTIU6 S-26PTIUG S-42PTIUS
a AA PN Р-р
Recessed 2 | ZZ NN «^^ |
CS-KS12NB41 CS-KST8NB4UW S-26PU1U6 SP 2701
Concealed
Duct
Outdoor | a
CONSITUNTA CU U-36PSTUS =" 5 U-A2P51U6
MULTI ZONE MODELS
Series S series JE series KS seis / KE series
Btu/h 9,000 | 12,000 7,000 9,000 12,000 18,000 24,000
Wall - ni
Mounted ——]s=——] —
i Е CS-SINKUW-1 CS-S12NKUW-1 CS-MKS7NKU CS-MKSYNKU CS-MKST2NKU CS-MKSTENKU CS-MKSZ4HKU
13 am | en
- |
E e. {== a — N = a
Le]
x CS-MKSINB4U CS-MKSI2MB6U CS-KS18NBLUW
Bu 18,000 | 19,000 24,000 31,000
5 = = = = =| =
ow | @ ® | a ©
‚— су-2510нву-1 - = Й cu-3Ksi9nBU = CU-4KSZANBU > 4 cuassimeu
Btu/h 9,000 | 12,000 7,000 9,000 12,000 18,000 24,000
= CS-ESNKUAW CS-ET2NKUAW CS-MKESMKU CS-MKET2NKU CS-MKETENKU CS-MKEZANKU
> = | NN
= Calg LA NN LI
= CS-MKE9NBAU CS-MKET2NB4U CS-KETBNB4UW
Btu/h 18,000 19,000 24,000 31,000
Е — = ES =
== e @ 2 ©
CU-2E18NBU - - Ÿ cu-akE19NBU - — CU-LKEZ4NBY =P cu-4KEJINSU
Model Feature Chart
OP: Option
UT RQ Le STANDARD LOW-AMBIENT AIR CONDITIONERS
ESNKUA SINKU-1 | SINKUA
3 __ | Watt Mounted | E ADA EA es 26PEK1U6 Tot eu E. 26PSKIU
$ = Ceiling Suspended oli a
>= 42PETIUS 42PSTIU6
pus 26PEUILE 26PSUTUG
E 2 Ceiling Recessed e be seau réa
E vo Concealed Duct da es
= A ECONAVI 6
EM | "Protection | ©
CA | E e |e e о ® | ® | ®
6° ss Remote | ® OP | OP | OP © OP | OP | OP
Mes | OP | OP | ОР | ОР | ОР | ® | ® | ® | - | ОР | ОР | ОР | ОР | ® | ®@ | ®
e | e e e e e e e e e e e e e e e
Dry Mode e | e el e el e e e el e ele se e e e
EA atmen | @ | ® | @ | ® | ® | ® | ®@ | ® | @ | @ | ® | ® | ® | ®@ | ® | ©
AirSweepControt| ® | ® | ® | ® | ® | @ | ®@ | - | ® | ® | ®@ | ® | ® | @ | ®@ | -
wercontrol | ® | © | © | e | e | e j ® | ® | ® | ® | ® | ®@ | ® | -
Е once @ | ® | @ | ® | ® | ® | е | ® | - | - | - | - | - | - | - | -
mo = |= | ® | - | - | - | - | - | - | ® | ® | - | - | - | -
HR Hsing Ф | ® | @ | @ | ® NAT
[Brn Ф® | @ | ® | @ | ®@ | @ | @ | @ | ® | ® | ® | @ | ©
LTH] 1-Hour OFF Timer - - ® 1 - - - - - - = = =
WEB) | weekty Timer | - Е - - | ОР | ® | e e - - - - | | e | e | @
uu System Controller | - - - - OP ОР ОР ОР = = = а ОР ОР ОР ОР
НЕЕ Filter Sign - - - - © - - - - - - - © -
pue | © | © © | ® ® | ® | ® | ®@ | ®@ | ® | ® © ®
FreshAirintake | - | - | = | ® | - | оР* | оР | оР* | - | - | - | ® | - | оР* | оР | op*
Branch Extension - - - ® - - o ® - - - o - . o o
DA Built-In Drain Pump | = - - o = a ® © = = = o = с o a
КД | ео | ® | ® | ®@ | - | ® | ®@ | ®@ | ® | - | ®@ | ®@ | ®@ | ® | © | 0 | ®
PE |r ® | ® | ® | ® | 0 0 0 0% © © @ | ® | ® | ® | ©
0DP=0 Refrigerant | © | © | © | © | ®@ | ® | ®@ | ® | © | ® | ®@ | @ | ss el e e
QietMode | O | ® | ® | ® | - - - - | ® | ®@ | ® | ® | - - - -
mises |. [+o|-|-|-|-|-|-|j<|e|-[|-|-|-|-|-
dar |e|e|-|-|-|-|-|-|*e|*1|-1-|-|-|-|-
* Field Supplied
Features
o
SE ECONAVI
ECONAVI features intelligent Human Activity Sensor and new
technologies that can detect human activity and absence, and
optimize air conditioner operation according to room conditions.
ef Room Freeze Protection”
Room Freeze Protection mode helps prevent plumbing damage
due to sub-Freezing Temperature. This mode automatically
turns on the compressor for heat pump operation if the room
temperature falls to about 46°F.
*This function may not be performed if the unit is not powered,
or if the unit is unable to operate such as in protection mode.
Please consult with the HVAC installers or professional for
details.
Microprocessor-Controlled
Operation
Microprocessor control ensures that the temperature and
humidity levels in the room are always comfortable.
N Wireless Remote Control
Panasonic's infrared Remote Control with and easy-to-read LCD
Display, gives the user the capability to adjust & set: tempera-
ture, sweep [louver control, fan speeds, timer and more, for
complete automatic operation.
Dry Mode
By coupling compressor and fan operation, intermittent operation
can be precisely controlled according to room temperature, so
that air is efficiently dehumidified.
5 Fan Speeds and Automatic Fan Operation
Convenient microprocessor control automatically adjusts fan
speed to High, Medium or Low. According to room temperature to
maintain a comfortable airflow throughout the room.
Air Sweep Control
The air sweep function moves the louver up and down in the air
outlet, directing air in a “sweeping” motion around the room and
providing comfort in every comer.
Louver can be manually set to the desired angle by remote
control.
After setting the temperature and functions you desire, just relax.
If the room temperature is higher than the set temperature,
cooling operation begins. If the room temperature is lower than
the set temperature, heating operation begins. During normal
thermostat cycle operation, cooling and heating operations
automatically change in accordance with set temperature, time
and room temperature (Single Zone Heat Pump unit only).
1-hour OFF Timer
When this button is pushed either while the unit is operating
or while it is stopped, the unit will operate for one hour, then
switch off automatically.
PROGRAM
: [24H | 24-hour Clock with ON/OFF Program Timer
: The remote control unit allows you to set a wide variety of
: timer-based operations. Such functions include automatic
: ON/OFF with a timer setting, same time ON/OFF every day, ON
: timer, OFF timer and Combination timer.
: ЗЕ
: Night Setback Mode for Cooling and Heating
: Cooling and DRY Mode: With the Night Setback Mode, the
«gir conditioner automatically raises the setting temperature
: 21°F after 30 minutes, and then another 2°F after the next 30
: minutes.
: Heating Mode: With the Night Setback Mode, the setting
: temperature is automatically lowered 4°F after 30 minutes, and
: then another 4°F after the next 30 minutes. This saves energy
: without sacrificing comfort and is ideal for gentle cooling and
: heating.
In Cooling and DRY Mode
2°F
Setting
temperature —
1 A
I
p the 30 min. 30 min.
NIGHT SETBACK button Time
In Heating Mode
temperature —
4
4'F
i
|
the 30 min. 30 min.
Press i
NIGHT SETBACK button Time
Failure
: ВА Automatic Restart Function after Power
: This feature allows the system to automatically resume
: operation at its preset program, after power is restored from a
: power failure when the remote control is in the room.
: Hot Start Heating System
: Right from the start, air is warm and comfortable. The Hot Start
: Heating System prevents any cold blasts at the beginning while
: the heat pump is warming up (Heat pump unit only).
: {DP} Built-In Drain Pump
: Max. head 20 inches from the discharge of the indoor unit.
+ Condensation pump is only for allowing drain Line to meet
: minimum gravity flow requirements.
ELECTRIC Electric Refrigerant Control Valve
The circulation volume of the refrigerant is controlled by a pulse
type electric control valve. In order to attain optimum efficiency,
when the power is switched ON, the opening degree of the electric
control valve is controlled between 90 and 480 steps.
«| ui
LOW, low fan speed for extra quiet operation.
Filter Sign
Filter sign informs you when filter maintenance is necessary.
2,500hrs : U1-series / 150 hrs: K1-series
[Example of CZ-RTC2)
Self-Diagnosing Function
Units are equipped with Self-Diagnosing Function (methods
are difference depending on the models). This makes it easier
to diagnose malfunctions, greatly reducing service labor (Wired
remote controller].
[Example of CZ-RTC2)
RR Anti-microbial Filter
Anti-microbial Filter by 3M. This filter is treated to inhibit the
growth of mold and mildew, and helps create clean air.
Test Comparison
Microbial Growth Rating
7 days days
Anti-microbialFilter Mo growth Mo growth
‘Normal Filter Paper 50% growth 60% growth
*Tested per ASTM 671-96
442) Blue Fin Condenser
Condensers can take a beating from exposure to salty air, rain
and other corrosive factors. Panasonic has extended the life of
its condensers with an original anti-rust coating.
Special Coating Layer
(Fin Cross-section)
Water Ar Bat coment
2%
PEA LLL AT
PEEL EA EEE
Passe Mafia Con mara yw
Ti
CO
ak]
—
=
ae)
in
с
=— и
ful]
B=
=
E
|
E
==
== |
==
New Deluxe Wall Mounted Heat Pump Series
Panasonic Adding New Air Conditioner Lineup—
Setting Another Mile Stone in the US Ductless Split History
Breakthrough technologies such as the inverter enable
the highest energy efficiency* in the industry. Thanks to this exceptional
performance, you enjoy even more comfort. (
EXTERIOS
Pr
a
Indoor Unit Wireless Remote
CS-XE9PKUA / CS-XE12PKUA Controller
No.1* High Energy Efficiency
Breakthrough technologies, such as the inverter, enable the highest energy
efficiency* in the industry. Thanks to this exceptional performance,
you will enjoy even more comfort.
*CS/CU-XE?PKUA as of March 2013
LOW Powerful Heating at Low Ambient Operation
e Heating is still possible even if the temperature drops as low as 0°F for
OPERATION reliable heating in even the harshest winter.
Inverter Technology
SIN VERTER Panasonic's inverter provides optimum power control and extremely
efficient operation by changing the power supply frequency.
The result is speedy, flexible operation using less electricity.
Panasonic ductless split system designed
to care for you
With more than 50 years of experience of exporting to more than 125 countries
around the world, Panasonic is unquestionably one of the leaders in the air
conditioning business. With more than 200 million compressors produced, you
are assured the high quality of Panasonic's air conditioners.
New added unique features
Advanced Inverter Technology—
Less Energy and More Comfort
The inverter constantly adjusts compressor rotation speed
to provide optimum performance at all times. This extremely
precise operation enables quick cooling or heating while
reducing power consumption compared to conventional non-
inverter units.
Reduces Electricity Consumption
Panasonic Inverter air conditioners are designed to give you
the exceptional energy savings performance while ensuring
you stay comfortable at all times.
Constant Comfort
Precise temperature control with a wide power output range
enables an inverter air conditioner to meet different room
occupancy levels - thus ensuring constant comfort.
Quick Cooling (Heating]
Panasonic Inverter air conditioners can operate with higher
cooling power during the start up period to cool the room
faster than non-Inverter models.
Inverter Indoor Quiet Operation
Panasonic Inverter air conditioner's indoor operating noise
has been reduced by 5dB as the Inverter constantly varies its
output power to enable more precise temperature control.
HB The Advantages of Inverter Control
Comparing inverter and non-inverter air conditioners to cars...
NVERTER
WM Even Wider Output Power Range
Minimum capacity
2,800Btu/h
Rated capacity
8,700Btu/h
Maximum capacity
12,000Btu/h
The graph shows XE?PKUA's wide power output
range during cooling.
*Image ol outpul power Nuctuation
r
Cooler A Adjusts the accelerator and The accelerator can't be adjusted, so you spend a long
A В thus runs more economically. time getting comfortable, then soon become uncomfortable,
Uncomfortable
Reaches the comfortable Keeps the temperature
© zone quickly. ki comfortable all the time.
В 4
09 BE fe 0 asen cscacnecaaas |rsanecacecicarca caian fil fens ы | fas aa a a asa a EEE EEE EEE аны
m
o PE Prec
pe ———
=
=
E =— = mwa = rt trim - E PAPA
o Setting Temperature
o
a
Uncomfortable capt
Runs at a fixed speed and takes «Блу» == Inverter air conditioner
el Lo longer to reach the comfort zone. To eran io coli
Less Cool v ten too warm és = Non-inverter air conditioner
e
=
ECONAVI with Intelligent Eco Sensors
Lee ГЛ
Panasonic has employed ECONAVI [Human Detection Technology] in its air conditioners. Since in 2007 and has perfected the feature since its
launch. Panasonic is now introducing ECONAW air conditioner to the US market.
ECONAVI sensors moderate the temperature. This smart technology monitors and senses when there are people in the room and determines how
much activity is occurring, then automatically adjusts the temperature setting accordingly for optimum operation.
The low activity detection mode monitors the room, decreasing cooling when there is less movement, while the absence detection feature switches
to a slightly less powerful cooling mode when there is no one in the room at all.
Absence Detection
ECONAV! detects human
absence from the room
and raises the target
temperature.
power when you are not
mom
„=
FP
=
Absence Detection
Reduces cooling and heating
ho one sn the mom
Detects absence
CONTROL
L
Gradually modulates cooling
power by setting the new
target temperature
(set temp +4 FI
Activity Detection
ECONAVI detects changes in
activity levels and reduces
the cooling power by
adjusting set temperature.
EI CONTROL
Level of activity is
decreased, Detects [ow
achvily.
Reduces cooling power by
setting new target
temperature
Iset temp +2"F]
ECONAM in cooling mode: “The target temperature set by ECONAVI wall be restored automatically to the set temperature when the new condition is detected.
RENEE
in the i
H How Does ECONAVI Human Activity Work?
ECONAVI
+4%F
Set Temperature
[1]
Present
Activity Detection
Adjusts cooling and De
heating power to your Ld)
activities.
Human
Activity Sensor
-2°F
Fan Speed
—20min—} 4 +2°F
SE EE EE E E o. — Ч
SEE
Max Medium Fan
Legend:
Set Temperature
Cooling Power
— Heating Power Remark: Set temperature on remote control display remains unchanged.
10
Wall-Mounted Heat Pumps
EXTERIOS
С | |
Indoor Unit
CS-XE9PKUA / CS-XE12PKUA
=
За ес Wired
Wireless Remote Controller
2 Remote (CZ-RD516C])
= Controller = (Optional)
Outdoor Unit
CU-XE9PKUA / CU-XE12PKUA
eE
SEES
oy
=
=
=
[= 5
Er
La
[=
— =
=
a
pre
=
=]
=
=
—
rem]
=
SOHNE Er EAE
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. [Refer to the table on the P.34 in the catalog for more detail.)
B= PA Bs B= Pi 2--
п ое [Вет ЕВЕ [Sem (Si С) [TH
Wall-Mounted Heat Pumps
E9NKUA / E12NKUA E18NKUA / E24NKUA
vu \ | iF | = = — 7 >
Indoor Unit Indoor Unit
CS-E9NKUAW / CS-E12NKUAW CS-E18NKUA / CS-E24NKUA
Panning
aa
Ш
caf
a
E Wired
24 Wireless E Remote Controller
Teja da
= Wired
тыщ Wireless DI Remote Controller
5 Remote (CZ-RDS16C] = F +5 Remote (CZ-RDS16C]
= = Controller re (Optional) > ony = Controller 5 Optional)
Outdoor Unit Outdoor Unit
CU-E9NKUA / CU-E12NKUA CU-E18NKUA / CU-E24NKUA
# =
ELE E
ga): A A PIECE
[=]
—
—
€
=]
=
=
ir
co
E
=
o
er
—
©
—=
=
=
LE
SSI
11.40 / 12.60
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the P.34 in the catalog for more detail.)
ee Es [ee Bes. Bx [se MP]... Ri Elan 12
Wall-Mounted Heat Pumps
oy
=
=
=
[= 5
Er
La
[=
— =
=
a
Fer
=
=]
=
=
—
—
=
KE3ONKU / KE36NKU
TT оч = = —]——:—; ————— —
чё = === |
i Indoor Unit
Indoor Unit
S-26PK1U6 CS-KE30NKU / CS-KE36NKU
= ir?
Е re
pr 2
a a | =
A | | Eo ixt
A — A = N | i
E Wireless Wired Remote Outdoor Unit Wireless Wired Remote
. Remote Controller Remote Controller
Outdoor Unit Controller CZ-RTC2 CU-KESONKU / Controller CZ-RD515U
U-26PE1U6 (optional) CU-KE36NKU (optional)
Unit Model No.
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. [Refer to the table on the P.34 in the catalog for more detail)
== a В © Br SS a Yes 65 Q= DRY re
Wired
Contrel
Built-in
CZ-RDS15U & CZ-RC515UA
and
§ Fan Ar Sweep Louver rc
speeds er
C1-RO515U & CZ-RC5ISUA
7479
She
pra
|
к Vi 24H | 2 timer
[TU
Wall-Mounted Air Conditioners [Standard Models |
S9NKU-1 / S12NKU-1 S18NKU-1 / S22NKU-1
je F 5 ] — 7
Indoor Unit Indoor Unit
CS-S9NKUW-1 / CS-S12NKUW-1 CS-S18NKU-1 / CS-S22NKU-1
Parayonio
"Асти e
. т -
es 25
== = TE =
= + ~ ES =
Outdoor Unit Nines Outdoor Unit sic =
emote emote ow
CU-S9NKU-1 / ur CU-S18NKU-1 / Controller =
CU-S12NKU-1 CU-522NKU-1 =
«ОЧ =
=
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. [Refer to the table on the P.34 in the catalog for more detail.)
ee He [fe Ее ble Ms. Ka = 14
Wall-Mounted Air Conditioners ~~ [rovamientwores | |
SONKUA / S12NKUA S18NKUA / S24NKUA
at | =] ==" qu 7
Indoor Unit Indoor Unit
CS-SINKUA / CS-S12NKUA CS-S183NKUA / CS-S24NKUA
Prima: mar:
mal on al
= — TE:
= ен о im
T = Ti
DI Ro =
—
= = я
—
Cw =
ЦОК
id
I
+
i
~~
=
sl
a
LA
Outdoor Unit Wired Remote Outdoor Unit Wireless Wired Remote
CU-S9INKUA / Remote Controller CU-S18NKUA / Remote Controller
Controller CZ-RD516C Controller CZ-RD514C
CU-S12NKUA [optional] CU-S24NKUA НИЕ (optional)
SSA AENA Е
f=
pr
=
=]
=
n=
=
[=]
cs
mes
<T
=
a
ui
=
=
=
=
—"
E
со
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. [Refer to the table on the P.34 in the catalog for more detail.)
a a [Ser [$e (Oe D> (RR) (A [A Els EB. PR Ш
Wall-Mounted Air Conditioners ~~ [tow antienhodss | |
KS30NKUA / KS36NKUA
— —o _——Z;;;;—;——;;—;—;——;—;——;—;—;—;—— = ча NA,
Indoor Unit Indoor Unit
S-26PK1U6 CS-KS30NKU/CS-KS36NKU
и
BR RS
“RP | |
= 4 | |
4 | | | =
7 ja Pet Ey Th
Outdoor Unit Wireless Wired Remote Outdoor Unit Male Wied Remote
Remote Controller + emote ontroller
U-26PS1U6 Remote Ce CU-KS30ONKUA/ Remote controlen
(optional) CU-KS36NKUA [optional]
cos
=
=
[=
=
— |
ze
o
=5
—
ES
=)
==
="
cr
=
=
co
==
This is maximum elevation difference when the indoor unit is located above the outdoor unit, (Refer to the table on the P.34 in the catalog for more detail.)
gan [EEE Fn... re Mir... ZAS
i Faiter sign he Ест Hie Dr mer E
кз [сое о рн [Ее
RAC Multi-System Indoor Units
Fits with Various Sizes of Rooms and Lifestyle
The multi-system type allows a single outdoor unit to be connected to
2 indoor units. It also solves the problem of limited installation space and does not clutter
the exterior of your home.
CS-SONKUW-1 / CS-S12NKUW-1
CS-E9NKUAW / CS-E12NKUAW Рес I
E Wireless
— == Remote Controller
Tid “Included” with
| =F / Ë =
Indoor Unit: Wall Mounted Type
5
&
=
=
=
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the P34 in the catalog for more detail.)
> E fe Be Ye = OE Gl (A Eis E Pi Ш
RAC Multi-System Outoor Units
CU-2S18NBU-1 / CU-2E18NBU
For Rooms
Air Circulation
Number of Connectable Indoor Units
SEER
EER
HSPF
Power
Maximum Fuse Size
Controls
Fan
Amount
Control
Sound Hi
Connections
Max. Allowable
Refrigerant Tube Diameter ~~ Narrow Tube
Unit Dimensions
Mel
CU-2518NBU-1 & CU-2ET18NBU-Cooling
Wide Tube
HxWxD
Ft.
inch
inch
inch
Lbs.
Auto
DC Inverter
R-410A / 67.8 07
Electric Valve
48
Flare
Max.164
Auto
DC Inverter
R-410A / 67.80 Oz
Electric Valve
Flare
Max. 164
Indaor unit combinations Room A Room B Total min - max Rating min - max Nm w W ptíh
Tom CS-SONKUW-1 / CS-EINKUAW 9,600 nun 9,600 6,200 - 11,200 850 390 - 1,020 45 41 11
CS-S12NKUW-1* / CS-E12NKUAW" 10,900 = 10,900 6,300 - 12,800 1,000 390 - 1.230 5.2 47 13
CS-SONKUW-1 / CS-E9NKUAW +
CS-SONKUW-1 / CS-EONKLIAW +
LAN | CSSIONKIW-1* + CS-ET2NKUAW" 7,800 8,900 16,700 7.200 - 20,000 1,450 390 - 1,870 16 65 11+13
CS-S12NKUW-1* / CS-E12NKUAW® +
cs SIOMIIN:1* / COEN 8,350 8,350 16,700 7,200 - 20,000 1,450 390 - 1,840 7.6 65 13+13
CU-2E18NBU-Heating
ope Poe сон | сен | Nas Remera Ve
Indoor unit combinations Room A Room B Total min - max Rating min - max “i N an ptíh
ren CS-EINKUAW 13,700 = 13,700 6,400 - 15,700 1,150 440 - 1,450 50 5.4 ==
CS-E12NKUAW 15,300 - 15,300 6,500 - 17,500 1,300 440 - 1.630 66 6D =
CS-EONKLIAW + CS-E9NKLIAW 10,100 10,100 20,700 7,100 - 24,600 1,850 40-210 9.0 El _
2 Room CS-E9NKUAW + CS-E12NKUAW* 9,400 10,800 20,200 7,200 - 24.600 1,850 420 - 2,290 9.0 8.1
CS-E12NKUAW" + CS-E12NKUAW" 10,100 10,100 20,200 7.200 - 24,400 1,850 420-2290 9.0 Bl =
"For CS-S12NKUW-1/CS-E12NKUAW, the pipe size reducer CZ-MATP must be used when connecting with multi-zone outdoor unit.
== Г. =
ra Ces. Dejes in fe [Il (pl ser 8
5
Е.
=
7
3
RAC Multi-System Indoor Units [KS/KE Series |
Fits with Various Sizes of Rooms and Lifestyle
The multi-system type allows a single outdoor unit to be connected to
2 to 4 indoor units, It also solves the problem of limited installation space and does not
clutter the exterior of your home.
CS-MKS7NKU / CS-MKS9NKU / CS-MKS12NKU $ CS-MKS18NKU / CS-MKS24NKU
CS-MKE7NKU / CS-MKE9NKU / CS-MKE12NKU $ CS-MKE18NKU / CS-MKE24NKU
+
J
Wireless Remote
Controller
[Included]
with each indoor
“ей
Vel
E LK >]
Le > 69 WE Controller
и ce
optiona
Indoor Unit: Wall Mounted Type
E
Е
:
=
218 294
27
33/30/77/73 34/31/9115
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalog)
[Y E [Be [Ne
ihr WEEKLY) veers
Timar al mr
RAC Multi-System Indoor Units | KS/KE Series | |
Fits with Various Sizes of Rooms and Lifestyle
The multi-system type allows a single outdoor unit to be connected to
2 to 4 indoor units. It also solves the problem of limited installation space and does not
clutter the exterior of your home.
i NSTI ER
$ ¢ Wired Remote
= Controller
EE x Sea
| Controller Wire Kit Mr PROGRA!
[Included]
CZ-RC515U Г
— with each indoor [Optional] 1H
Tien
Indoor Unit: Ceiling Recessed Type
Е
=
=
E
=,
221 à 206 / 194
247
32/31
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. [Refer to the table on the back of the catalog)
Fon A
= Ep. Bi Pine [AOL mer su,
wo [El gi EF >
RAC Multi-System Outdoor Units | KS/KE Series |
Connectable from 2 to 3 Indoor Units
CU-3KS19NBU
CU-3KE19NBU
Outdoor Unit
Air Circulation
Number of Connectable Indoor Units
SEER
E
Е
:
=
Amount at
Control Electric Valve
Sound Hi 50 50
Connections Flare Flare
Max. Allowable with additional 82 [per Unit) 150 with additional
Refrigerant Tube Diameter — Marrow Tube x3 x3
Wide Tube x3 x3
Unit Dimensions HxWxD X X X
Net 138.9
RIT is not possible to connect an outdoor unit to only à single indoor unit. If operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause a malfunction.
* Test Conditions based on AHRI 210/240
п Mi [BE [Ne
RAC Multi-System Outdoor Units | KS/KE Series |
Connectable from 2 to 4 Indoor Units
—_— _
=i
Up to Rooms
CU-4KS24NBU CU-4KS31NBU
CU-4KE24NBU CU-4KE31NBU
Outdoor Unit
Air Circulation
Number of Connectable Indoor Units
SEER
EER
HSPF
Е
=
=
E
=,
60Hz 60Hz 60Hz
19,7 / 11,9 8.7/9.6 10.0/11.0 1.47124 10.1/11.2
2,420 1.950
20A 20A
Auto (Hi, Me, Auto [Hi, Me, Auto (Hi, Me,
DC Inverter DC Inverter DC Inverter
Amount at : R-4104/ 6.17 R-410A / 6.17 - | R-4104 / 8,38
Control Electric Valve Electric Valve Electric Valve
Sound Hi 50 50 52 53 55
Connections Flare Flare Flare
87 [per Unit) 200 with addi- | 87 [per Unit) 200 with addi- |100 [per Unit) 230 [per with (per Unit) 230 (per with addi-
Max. Allowable Tubing Length tional tional tional tional
Refrigerant Tube Diameter — Narrow Tube x4 x4 x4 x4
Tube inch Xx3+1/7 x1 X3+1/7 x1 X2+1/7 x? Xx 2+ 1/7 x2
Unit Dimensions HxWx inch X X X x 12- X X
Lbs. 138.9 143.3 174.2
Da is not possible to connect an outdoor unit to only a single indoor unit. Hf operated with only ONE indoor unit installed, the returning refrigerant to the compressor may cause à malfunction,
[IMPORTANT |
* Test Conditions based on AHRI 210/240
Pos [me Eevee [TT ai [Rp [Efren 22
RAC Multi-Combination Tables Cooling
Most popular combinations refer to technical manual for complete listing of combinations.
CU-3KS19NBU/CU-3KE19NBU 230V
6,578
8,981
8598 | 10,031 | 24600
7,379 | 12208 | 24.800
5
=
=
=
7,300
10,101
12,775
7.964
9,673
6218
23
CU-4KS31 NBU 230V
Indoor Unit Combination
wajsks mn avy
6.636
5,530
4,761
+
+ | + |+ + | + | + | + | + | +
7,650 7,650 7,850 | 7,6507 30600 9,800 : 8,000 8,000 8,000 | 8,0007 32000 11.600
24
Ceiling-Suspended Air Conditioners and Heat Pumps
| 26PST1U6 36PST1U6 / 42PST1U6
26PET1U6 36PET1U6 / 42PET1U6
Indoor Unit
= | Indoor Unit Е —
A S-36PT1U6 / S-42PT1U6
Вой S-26PT1U6
=
Wired Remote Controller
[C7-RTC2)lInciuded])
Wired Remote Controller
rr
(CZ-RTC2/[Included]
er
Outdoor Unit Wirless Remote Controller Outdoor Unit Outdoor Unit Wirless Remote Controller
U-26PS1U6 / U-26PE1U6 — (optional U-36PS1U6 / U-36PE1U6 U-42PS1U6 / U-42PE1UG (optional)
SNE E
Lopthorall сова
Em
ry Icoalimg)
=
Zo
=
Е
о
; Quiet Operation Improved Serviceability / Easy
| В Installation
The ceiling-mounted unit is equipped with a highly efficient, multi-blade centrifugal fan that generates a powerful,
yet gentle airflow throughout the room. External suspension method.
A redesigned aerodynamically tested louver structure minimizes operational sound even at high fan speed. Installation 1 el ortened |
= la
== |
pe
oo
Improved accessibility to electronic
components (control box) for serving.
25
Fresh Air Intake Capability and
Duct Extension
Auto-Louver Function Provides Optimum Airflow During Heating
or Cooling Operation
Ceiling-suspended models have the capability of bringing fresh
Auto-louver function is a standard feature which provides optimum airflow during heating or cooling operation.
air from outside using an air-intake duct [field supplied).
Angle of louver is automatically set for heating or cooling. For example, when heating with fan speed set
to low, the discharge is aimed downward so that warm air reaches the floor. The louver angle can be set to
between 4°F above and 80°F below the horizontal in five steps. An auto-sweep function to distribute the
airflow over a wide area is also provided. Wind direction is adjusted automatically in both heating and cooling
operation. The louver can also be set
Uy from FI
to swing automatically from |
to F5 in any operation mode (heat = — а
pump type onty).
5 [oHeatingFi-Fs
[Cooling F1~F3 |
Air Conditioners
Ceiling - Suspended
Heat Pumps
Model No. 26PST1U6 36PST1U6 42PST1U6 26PET1U6 36PET1U6 42PET1U6
Unit Model No Jodoor UL] Outdoor Vat | Tadeo lt] Outdoor Un | Indoor Uni | Оибюгий | ImdoorUnit | Oddeorlot | IndoorUmit |. ue Ua | IndoorUnit Cudoor Uni
S26PTIUG | U-2005106 | S-26PTIU6 | U-36PSIU6 | S-A2PTIVG | U-12PSIUS | S-200TIU6 | U-20PE1V6 | S-36PTIUG | U-36PEIUG | S-42PT1UG | U-42PEIUG
Performance 8 Electrical Ratings
Capacity Cooling Bab | 26,000 (9.500-24,400) 31,200 (9.500-31,200] 29,009 9.500-29 000 24.400 9500-24 40) 31,2009 500-3100 29,000 (9.500-39,060]
Heztng вол = = = 20,800 (£,000-20 800 1,400 (8000-37400 4500 8,000-44.50
Moisture Removal High Pints/H 17 100 126 17 100 1.4
Dry Ar Flow Hi/Med/ Low — UM 550/4907 48 1,100 /930/ 750 1.13050 775 550 / 490/460 1,100/930/ 750 1.130/950/ 775
SER Cooling 145 151 5 15 151 5b
EER Cooling 86 8.10 YA 85 8.10 94
HPF Heating = = = y T 5
Power Supply Y, Phase, 230/208/1/68 70/28/1180 200/208/1/60 230/208/1/60 230/208/1/00 290120811160
бий Ану: Cooling Á 1547173 12/21 11/23 156/172 162/01 11/23
Heating Á = =: = 164/181 156/173 186/20
Per Input Cooling W 2800/2000 300/3000 {10/416 2800/2000 300/3040 (160/416
Heating W = = = 3000/30 250/88 3.30 3.8%
Fe or Circuit Break Capacity AD 9 5 | % 5 [Tu 5 | a Ss 1 u
Controls Microprocessor Mieroprocessor Microprocessor Microprocessor Microprocessor Microprocessor
Low Ambient Control [for Cooling) Built-in 0°F Built-in 0°F Built-in 0°F Built-in °F Built-in 0°F Built-in DF
Wireless Remote Contoleroptonal CI-RWSU2U, C-RWSCIU CZ-RWSUZU, CZ-RWSCIU CZ-RWSUZU, CZ-RWSCIU CZ-RIWSUZU, CLAWISCIU CZ-RWSU2U, CLAWISCIO CZ-RWSU2U, CZ-RWSCIU
Wired Remote Controller (included) СИТО? CZ-RTC2 СТО! CZ-RTC2 CI-ATC2 C7-RTC2
Fan Speeds 3 and Automatic Control Variable | 3 and Automatic Control / Variable | 3 and Automatic Control / Variable | 3 and Automatic Control / Variable | 3and Automatic Control Variable | 3 and Automatic Control / Variable
Timer 7 Days/6 Events 7 Days Events 7 Days/6 Events 7 Days/6 Events 7 Days/é Events 7 Days/6 Events
Air Deflection Horizontal = E = = = =
Vertical Automatic Automatic Automatic Automatic Automatic Automatic
für Fite Washable Washable Washable Washable Washable Washable
Refrigerant R-410A R-410A R-410A R-410A R-410A R-410A
Refrigerant coed Electric Expansion Valve Electric Expansion Valve Fectric Expansion Valve Electric Expansion Vale Electric Expansion Valve Electric Expansion Valve
Operation Sound оне) BA 33113 42/00/55 MIET 371% 42/40/55 ME
Otdoodi] dBA 9 7 я @ я Si
Refrigerant Piping Type Flare Fare Rare Flare Flare Flare
Discharge о a" w a LE y a
Sucton ches ir 5 sir ir sr TT
RefigerantPige Leng й Nar 165 Nar 165 Max. 165 Mat 165 Max. 165 Max. 165
Elevation Difference® Outdoor Above ft Max. 100 Max. 108 Max. 100 Max. 100 Max. 100 Max. 100
Outdoor Below FL Ma. 50 Max. 58 Max. 50 Mar 50 Max 50 Max. 50
Dimensions 8 Weight indoor Uni | Odtowlot | iowUst | OoorUol | bdowlnt | OtoorUk | mdoorbm PTE" TE Outdoor Un TE" utdoor Uni
Height ces | 7. | ar | Mw | mir | eme | ame | une | wane | vine | sane | an | me
Vid Wes | 51-304" y RINT т ELIT 7 51-16 y TE y EA у"
Depth inches | 26-38 13-38" 2-38" 3-8" 24-38" 13-38" 26-38" 13-48" 1-38" 13-308 26-38° 13-3/8°
Net Weight Lbs. 57.0 128.0 BN 141.0 BUD 20 57.0 128.0 84.0 161.0 BUD 200
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the back of the catalog)
26
Ceiling-Recessed Air Conditioners and Heat Pumps
KS12NB41 / KS18NB4UA (15V)
a!
KE12NB41 / KE18NB4U
Indoor Unit =
vien ä Outdoor Unit 7 Outdoor Unit
CS-KS18NB4UW 0
CS-KE12NB41 [=i CU-KS12NK1A CU-KS18NKUA
CS-KE18NB4UW op va | | CU-KE12NK1 CU-KE18NKU
; = Tae, 1 A - : :
Grille Assembly P= EI = AA DRY 7 e] | 24H
CZ-18BT1U es = | “ Wirless Wired Remote ZN) DRY 2e
Remote Controller tope
Controller CZ-RD515U Hl = = =)
mad a WE ES ER ED ET
pT
Ds Tea)
36PSU1U6 / 42PSU1U6G
36PEU1U6 / 42PEU1U6
Indoor Unit ; Indoor Unit
S-26PU1U6 NS Whey S-36PU1U6 / S-42PU1U6
Grille Assembly a > Et = Grille Assembly
CZ-24KPU1U nm CZ-36KPU1U
Poe
==
“= || Outdoor Unit Wired Remote Controller = | Outdoor Unit ~ Outdoor Unit Wired Remote
- ntroller
pr | U-26PE1U6 Wirless Remote Controller Es U-36PE1U6 И =] U-42PE1U6 — [Included]
= 2 (optional) = ” - Wirless Remote
E
Controller
(optional)
3 El 28 A BE
{=
а НА |
G
= —
e
OÖ =
A Où
4-Way Airflow Design Sends Cool Air Integrated Drain Pump
ait ae = . [ЕЕ [ЕЕ
in all Directions ES. ES] 77] rain pumps but into the unit to raise the condensate
==
a
Air is retumed through the center of the grille, while eventy E up 20 inches from the drain pump discharge.
distributing air through each of the 4 supply air openings.
Installation in the center of the room provides for the greatest
comfort. However, 1 or 2 supply louvers can be closed for
installation near 1 wall to provide 3 or 2 way airflow. Also,
by closing off 1 supply louver,
you may attach a duct (field
supply) to the upper plenum and
provide conditioned air to another,
separate area.
Fresh Air Intake Plenum (Option)
When used to take in fresh air, attach the fresh
air-intake plenum to the unit,
Air-intake plenum is optionally supplied.
; , : CZ-26BCUTU for
Whisper-Quiet Operation S-26PU1U6
Thanks to the newly developed turbo fan and decreased C7-42BCU1U for
resistance of the air path, one of the industry's lowest S-36/42PU1U6
levels of noise has been achieved.
27
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. [Refer to the table on the back of the catalog for more detail |
28
Concealed Duct Air Conditioners and Heat Pumps
29
Indoor Unit
S-26PF1U6
Supplies are 8” dia
Re) == |
foptienal)
Outdoor Unit Уно Репино
U-26PS1U6 [CZ-RTC2)
U-26PE1U6 (included)
Outline diagram with medium or
high-performance filter field installed.
Built-In Drain
Pump
Drain pump is built into the
20 inches from the drain pump
discharge.
unit to raise the condensate up
Indoor Unit
S-36PF1U6
Supplies are 8" dia
a
| DO
a
Outdoor Unit bencina er
U-36PS1U6 [CZ-RTC2]
U-36PE1U6 Mena
a! mb > TT Es
CED 3
Sawplind
Installation Example
The picture shows the standard ducting system, where air is taken in from the back of the unit.
This system is useful
for places that need
extensive air conditioning,
including conference
halls, showrooms, and
restaurants.
** This is maximum elevation difference when the indoor unit is located above the outdoor unit. [Refer to the table on the back of the catalog for more detail)
Optional Accessories
Tube Size Reducer Locking Bracket
Condensate Pump
mere EE
CZ-MA1P for Remote Control ==
RCS5PS4B |
RCS4MHVB V ==
RCPTC110B 7 Ве.
- # dc
| Wired Remote Timer Remote
x AEG Controller Controller
a CZ-RD516C CZ-RTC2
Fresh Air Intake Plenum 7
Anti-microbial Filter > es В Ea 7
CZ-SA20P 8 © En
DE las les e a ias
- A FLE LES
Wired Remote System Controller
CZ-RD515U CZ-64ESMC1U
Model No. Description Use With
és Insuiptac MON MA SATA HERS S9NKU-1, STZNKU-1, SONKUA, STZNKUA, KST2NB4IA, ESNKUA, EV2NKUA, KET2NBAT, CU-2SIBNBU-1,CU-2ET8NBKU, CU-3KSI9HBU,
DL04060820 Insulated Tubing Kit 1/4” x 3/8" x 1/2” x 20 CU-GKS24NBU, CU-GKS3INBU, CU-3KEI9NBU, CU-KEZANBU, CU-GKESTNBU,CS-MKSINKU, CS-MKSONKU, CS-MKSTZNKU CS-MKE7NKU,
DL04060835 Insulated Tubing Kit 1/4" x 3/8" x 1/2” x 35 SEHE SEN ET
DLO4080815 Insulated Tubing Kit 1/4" x 1/2" x 1/7" x 18
es || LE EE AE ET
DLO4080835 Insulated Tubing Kit 1/4” x 1/27 x 1/2" x 35"
DLO4 100820 Insulated Tubing Kit 1/4 x 5/87 x 1/77 x 20"
DLOG100830 Insulated Tubing Kit 1/4" x 5/8" x 1/27 x 30 KSZANKUA, KEZANK, CU-4KS24NEJ, CU-4KS31NBU, CU-4KEZ4NBU, CU-4KESINBU, CS-MKS24NK CS-MKEZGNKU
DLO4100850 Insulated Tubing Kit 1/4” x 5/8" x 1/2” x 50
DL0610030 Insulated Tubing Kit 3/8” x 5/87 x 1/27 x 30 A\L 26,000 Through 42,000 BTU/h Models
DL0610050 Insulated Tubing Kit 3/87 x 5/87 x 1/27 x 50" AU 26,000 Through 42,000 BTU/h Models
C2-2680010 Fresh Ai Intake Plenum S-26PU106
CZ-42BCUIU Fresh Air Intake Plenum S-36PU1U6, S-42PU1U6
RCSSPSAB Locking Bracket for Remote Controller AIL 26,000 Through 42,000 BTU/h Models except 30 & 36
RCSAMHVB Locking Bracket for Wireless Remote Controller AILKS,KE,MKS & MKE Models
RCPTC110B Locking Bracket for Wireless Remote Controller AU S/E9,12,18,22,24 Models
CU-KEPPKUA, CU-XET2PKUA, CU-SONKU-1, CU-ST2NKU-1,0U-STBNKU-1, CU-SZ2NKU-T, CU-SINKUA, CU-STZNKUA, CU-STENKUA, CU-S24NKUA,
= néon HSA CET PTA UM E DE
CU-AKSZANBU, CU-4KS3INBU, CU-2E18NBU, CU-3KE19NBU,CU-4KEZANBU,CU-4KE3INBU
SI-30-120 Condensate Pump All 115 volt Models
$1-30-230 Condensate Pump AU 208/230 volt Models
CZ-RE2C2 Simple Wired Remote
AU 26,000 Through 42,000 BTU/h Models
CZ-RELCZ Simple Wired Remote with Backlight
CZ-ROS15U Wired Remote Controller AILKS,KE,MKS & MKE Models
CZ-ROS16C Wired Remote Controle XESPRUA, XETZPKUA, SINKUA, STZNKUA, SIENKUA, SZ4NKUA, ENKUA, ET2NKUA, ЕТВМКОА, EZ4NKUA
CZ-RC515U Wire Kit PCB Wire Kit for CZ-RDS15U - Required For Use With Al KSBKE Models except 30 / 36 =
CZ-RCS15UA Wire Kit PCB Wire Kit for CZ-RDS15U, CS-KS3ONKU, CS-KS36NKU, CS-KE3ONKU, CS-KE3ENKU ©
CLATC2 Wired Timer Remote Controller AIL 26,000 Through 42,000 BTU/h Models except 30 & 36 =
CZ-RWSKIU Wireless Remote Controller S-26PK1U6 / S-26PK1U6 2
CZ-RWSU2U Wireless Remote Controller $-26/36/42PT1U6, S-26/36/42PU1U6 =
CZ-RWSCIU Wireless Remote Controller S-26/36PFIU6 8
CZ-64ESMCIU System Controller AL 26,000 Through 42,000 BTU/h Models except 30 & 36
CZ-MAIP Tube size Reducer CS-STZNKUW-1,CS-ET2NKUAW (for connection with CU-2518NBU-1 / CU-2E18NBU]
US Replacement ME micobal Flo C5 HMA SIZAKUA SKIN, SENKIN1 C5 STANR, CSO, CS-S1EMKU-I, CS-SZZNKU-1, CS-EFNKUAWL CS-EIZHOMAM,
WINDE-1 Wind Baffle All models
30
Remote Controller Options for Models 26,000 Btu's and Larger
Wired Remote Controllers (Except KE30/36NKU, KS30/36NKU)
Timer Remote Controller
Simplified Remote Controller
= ELO ls ula Ces
=| olas lay CE Cors
CZ-RE2C2 CZ-RELC2 (with Backlight) CZ-RTC2 CZ-64ESMC1U
Key Features (Simple Remote): Key Features (Standard Remote/7 Day Timer): Multiple Zone Controllers.
* Thin and Easy To Read * Thin and Easy To Read The Air Conditioning Gateway.
* Simple To Install and Use * Simple To Install and Use Panasonic's system and intelligent controls are the
* Can Be Adapted for Use On All 26,000 * Can Be Adapted for Use On central nervous system of the conditioning system,
through 42,000 Utu/h Indoor Units. All Indoor Units the gateway to all data, temperature and system
* Mode * Fan Speed Control diagnostics and the heart and soul of conditioning.
* Fan Speed Control * Airflow Direction
* Set Temperature * Operating Mode [Heating/Cooling/Auto/Dry/Fan) Key Features [System Control):
* On/Off * Vacation Mode for Continued Energy Efficiencies = Controls Up To 64 Units Into 4
» Airflow Direction * Full 7 Day Set-Back Functionality, Individualized Zones
» Perfectly Suited for Applications Where With Up To 6 Time Periods/Day * Alarm and Operational Signal Output
Simpler Functionality is Required * Full System Diagnostic Capability * Single Access Points for All Connected
(ie: Hotel Rooms, Nursing Homes, Offices) (Diagnostic History Provides Immediate View of System Wired Remotes
Past and Present.)
Wireless Remote Controllers
Wireless Applicable Unit | ()]-series (Ceiling Recessed Type) For All Large capacity series
Remote Controller T1-series (Ceiling Suspended Type) Indoor Units
Built-in type External type
| * Signal receiving unit can be installed in the outer panel of * Separate type signal receiving unit.
| indoor unit.
||
« Control panel can be installed in the inside indoor unit.
i |
CO | K1-series
CZ-RWSU2U CZ-RWSC1U
Remote Controllers Functions
s: Controllable
x: Uncontrollable
=
=
с
ee
=
=>
A
=
S
cs
[uk]
wr)
[=]
=
e
=
Note:
— If you use both remote controller and system controller
concurrently, both controllers can be used on a last-
signal priority basis.
31
Benefits
* Highest efficiency in the industry with a SEER rating * Quick and easy installation of indoor and outdoor units.
of up to 28.5 as of March 2013”. * Wired and wireless remote controllers available at option
* Inverter Driven variable speed rotary compressor. (Except for some models).
* Precise compressor speed to match the building needs. * Single Point Power Supply reduces installation costs
* Quiet operation. (Comply with local codes on wire size).
e Designed to run longer periods at reduced speeds to » 7 Year compressor warranty and 5 year parts warranty.
improve dehumidification with local codes on wire size. LEN a of Hach 257
9,000 - 24,000 Btu/h single zone, KS30/36 NKUA, KE30/36NKU
For S9/12/18/24/NKUA, 59/12/18/22/NKU-1,
E9/12/18/24NKUA
Disconnect Switch
(Field Supplied) ©
G ( G)
1 115 or 208/230 1 3 — 3
2 gt 115 or 208/230 2 Disconnect Switch 2 2 ee
= > Y 12-15 VDC Signal а (Field Supplied) 7 7 {Find Supplied)
&
L1 Li Power supply
® (©) |5 1er Е L2 Single phase 208/230V 60Hz
6 CG Supply Disconnect Switch
iFredd Supplied) ( a — Ground
(6)——————6round
indoor Unit Outdoor unit Indoor Unit Outdoor Unit
26,000 - 42,000 Btu/h single zone wiring schematic (Except KS30/36NKUA, KE30/36NKU)
Outdoor unit
i 3 INV unit .
nter-unit power line pou L1* Power supply
Indoor 208 / 230 V, 60 Hz, 1-PH © 19 L2* 208 / 230 V. 60Hz, 1-PH
unit | = Ale ИЦ
Lo a © Grounding line
то 07 @
| Grounding ine APT ©
Remote = || 5
Controller я = = = — 18/2 Shielded cable required
WHT[9-9— |) ° —
BLK |@ y . *Disconnect Switch to be field supplied.
RAC Multi wiring schematic (example shown is with 4 indoor units)
4 indoor units with CU-6KEZ6NBU, CU-4KE31NBU For CU-2518NBU-1 / CU-2E18NBU
wo
[==]
CO
=
иг
7
—
=
Disconnect Switch =
(Field Supplied) =
or
=
1 Power supply 3
Single phase 208/230V 60Hz ©
a
Ground
*These wiring diagrams are for reference only. Please refer to installation manual for details.
*Please be sure to follow National/Local codes for installation
32
Operation Range
Cooling Models [S9/12/18/22NKU-1] RAC Multi KE Series Heating Models
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. mperature door Air Take TT
> Maximum 90°F DB / 74°F WB 116% 08 cooling dis НОВОЕ LA.
Minimum 60% 08 / 52°F WB 60°F DB / 52°F WB delimita SER STE SEV
Maximum 80°F DB / 67°F WB 75°F DB / 65°F WB
fours Minimum -"FWB/-"FWB 0°F WB
Low Ambient Cooling Models (59/12/18/24NKUA)
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Heat Pump Models (XE9/12PKUA)
00°F 08 | 76°F WB pere Temperature Indoor Alr Intake Temp. Outdoor Air Intake Temp.
Cooling A Maximum 90°F DB / 74°F WB 115°F 0B / 79°F WB
Minimum 60°F DB / 52°F WB 0°F DB(S18/24) / 5°Е 08 (59/12) Cooling "u 50°F DB / 52°F WB 0°F DB / °F WE
e Maximum 86% DB / -*F WB 75% 08 / 64% WB
о . . ;
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Heat Pump Models (E9/12/18/24NKUA)
Maximum 95°F DB / 71°F WB 115% DB Temperature Indoor Air Intake Temp. Outdour Air Intake Temp.
; Minimum 67°F DB | 57°F WB 0°F DB Maximum 90°F 0B / 74°F WB 115°F DB
я Minimum 60°F DB / 52°F WB 0°F DBIE18/24) / 5°F DB (E9/12)
Maximum 84°F DB / -°F WB 75°F DB / 64°F WB
Cooling Models KS30/36NKUA eos Minimum 60°F DB/-"F WB 5°F DB / -°F WB
LC EE Indoor Air Intake Temp. Outdoor Alr intake Temp.
7 tarea == Heat Pump Models above 26,000 Btu |
is Minimum 67°F DB [ 57°F WB 0°F DB Maxi 95°F DB / 71°F WB 115°F DB
эм Minimum §7°F DB / 57°F WB 0°F 0B
RAC Multi KS Series Cooling Models Maximum 80°F DB / 67°F WB 75°F DB / 65°F WB
Temperature Indoor Air Intake Temp. Outdoor Air Intake Temp. Minimum - РОВ / - РМУВ 5°Е ОВ
Maximum 95°F DB / 71°F WB 115% 08 Heat Pump Models KE30/36NKU
Minimum 67°F DB / 57°F WB 14°F DB LOTTE door Air Intake Temg Dutdoor Air Intake
Maximum 95°F DB / 71°F WB 115°F 08
я Minimum 67°F DB / 57°F WB 14°F ОВ
Maximum BO°F DB / 67°F WB 75°F DB / 65°F WB
Minimum -"FDB/-"FWE 0°F DB
Sanyo to Panasonic Cross Reference
A: Nout Png, CU: Coot Only RAC (37models) Controllers
Category Capacity FEN Min e. Category Model No. Model No.
PAC Outdoor 2types / 10models КМ Common | RCS-BHOGAABWL CZ-AWSCIU
capaci Cassette 1 ЖЗЛ CS-KS12NB41 Wireless RC | 4Way | — RES-SHB0AABIWL CZ-RWSUIU
Category Кн Model No. Model No. ze Panel PAR-X51872 C7-188T1U Wall Mont RES-SHIAAB C2-RWSKIU
26 CH2672R U-26PE1US | A cL CU-KSIZHKTA System Controller SHA-KC64UG CEHESHCTE
% CHD72R D-25PELU6 со |? Qu CO-KS 18MM Simple Remote RCS-KRIEG CZ-REICZ
Outdoor Unit 18 CL1872 CU-KSIBNKUA
He | « CHAZTIR U-42PENUS т — UT Simple NEW СВЕ
Wired RC
30 CH3082 CU-NESONKU т e EI u
PAC Ci 36 CH3482 CU-NESENKU en CS-KEI2NEG WirelessRC | Series | RCS-SHBOUAWL CZ-RWSU2U
2 SHER TU Mini Cassette | Im | 18 XNST872 CS-KETENBAUW STI-KCWI CZ-RCSISU
3% C728 U-36PS1U6 WP | Panel | PNR-XS1872 C2-18BTIU Wired it STK-KCWZ CLRESISUA
c/o a CAZTIR U-42PS1U6 Outdoor Unit 12 CH1271 CU-KETZNKI Wired RC STK-RCS-TTWSUA C7-RD515U
30 (3082 CU-KSIONKLA 7 KMSO777 CS-MKS7NKU
36 C3682 CU-KS36NKUA 9 KM50972 CS-MKSINKU
Wall Mount 12 KMS1272 CS-MKSTZNKU
PAC Indoor Stypes / 15models (13models, Panel : Zmodels) LL KMS1072 essay _— Accessories
Capacity Fed | 24 KMS2472 CS-MKSZANKU Category Model No. Model No.
Category ak Madel No. Model No. Multi | 9 XMSO972 CS-MKSPNB4U Fresh Air Way CMB-65J80U C2-26BCUIU
a Mini Cassette | C/O | 17 XMS1272 CS-MKST2NBAU intake L-Way CMB-GSJ140U C2-428CU1U
= ая Ter Panel | PNR:ASIO72 CZ-188T1U Outdoor STK-KSB2050 85600
у 4-Way mie mm TT 19 CMI972A CU-3KS19NBU Bracket STK-K5B5050 BS600
= Cassette Outdoor Unit 24 CM2472A CU-4KSZ4NBU
= Panel PAR-XHZ442 CZ-24KPU1U 3! CMITÍA CU-4KS31NBU
> Panel PHR-XH3642 CZ-36KPU1U в Ee TE
> Wall Mount | WP | 26 KHS2672R S-26PK1U6 9 KMHS0972 CS-MKE9NKU
36 K53082 CS-KS30NKU : x2
co с AS un 1" “e E seno Rating Conditions
Wall Mount 18 KMHS1872 CS-MKETENKU
we | stress ne Flexi | 2 KMHS2472 CS-MKEZGNKU
36 KH53682 CS-KE36NKU Malti | 9 XMHS0972 CS-MKESNEAU Cooling Heating
2% THW2672R S-26PTIU6 Mini Cassette | HP | 12 XMHS1272 CS-MKETZMBAU Inside
Suspended | WP | 8 THW3STZR S-36PTIU Panel | PNR-XS1872 CZ-188T1U air temperature BO°F DB / 67°F WB 70°F DB / 60°F WB
47 THWEZTIR S-47PTIUG 19 CMH1972A CU-3KE19NBU >
2 UNWZ672R 5-26PF106 Outdoor Unit 2% CMH2472A CU-4KEZANEU Outside 95°F DB [75°F WE) 47°F DB / 43°F WB
qe à VHW3672R S-36PFIU6 a CMH3172A CU-4KEJINBU air temperature
Tubing Sizes, Lengths and Elevation Differences, Refrigerant Charge Adjustment and Insulation Chart
R-410A 0.7
R-4104 0.16
R-410A 0.2
R-410A 0.27
R-410A 0.2
R-410A 0.43
R-4 104 0.43
—
=
en
==
[==
|=
се
=)
[f=
A
= =
1/83, 1/21 R-4104 0.22
3/87x2, 1212
34
Model code
RAC
Indoor Unit Outdoor Unit Set
IE-OEENEDE PU-DEENRLE DEERE
1 в El E EH в A BB BB о El E Bo HH EE
Series ModelType [Е connection configuration = Capacity Development [caso pe J vee Ю
Lin mp Te
nm Siodoorunit | MK: Indoor unit for Multi zone 5 - Cooling only Development | | 4: MiniCeñingRecessed | ¿aero вон: common use
E oor mc aia E. entreno Coma eE Series Ho. Ans 1 = 115, 60Hz EE
PAC
Indoor Unit Outdoor Unit Set
5) - 28 [Р)[9) [168 D-BEEHL e
Ш lems =
5 : Indoor unit
Cooling Capacity in BTUM | P : Large Capacity series F : Conceated Duct Development Series U6 : 208/230V 60H:
| 5: Cooling Only
U: Outdoor Unit pope
Cortified to 150 9001: 2008
EA Puremone HA AN-Conimunag MA
Gor E,
¡Cer нео МОНАЯ Нео
© US
runa CERTIFIED Zon
7 Ea (NP
ile. > Certified to 150 14001: 2004
- < pr cnn
WEAS Se Bf,
nasonic та еле
Corian yp Ba) VET: POM
Cer u
Panasonic Corporation of North America
Air Conditioning Group
1690 Roberts Blvd., NW, Suite 110, Kennesaw, GA 30144
WWW.PANASONIC.COM/AIRCON
Because its products are subject to continuous improvements, Panasonic reserves the right to modify product design and specifications without notice and without incurring any obligations.
©Copyright 2012, Panasonic Air Conditioning Products.
Do not add or replace refrigerant other than the specified type. Manufacturer is not responsible for the damage and deterioration in safety due to usage of other refrigerant.
September 2013