SCMT26940 | SCMT26940 ELECTRONIC ANGLE ADAPTOR instruction manual

EN
SPECIFICATIONS
Dear Customers,
Thank you for purchasing our digital angle meter. This manual will help you to use
the many features of your new digital angle meter. Before operating the digital angle
meter, please read this manual completely, and keep it nearby for future reference.
Display range
Range
0
7. Start/Setting button
8. Power on/Reset button
9. Communication Port
10. Battery Compartment
11. Magnet
A
BATTERY INSTALLATION B
• Remove the battery cover.
• Insert two AAA batteries matching the -/+ polarities of the battery
to the battery compartment.
• Put on the battery cap and rotate it tightly according to the following figures.
SCMT26940
9 sets
1
360,0° (increment 1°)
BN : 50
PC Connectivity *2
No
Bright LED
6 LED / 1 Red+5 Green
Button
5
Battery
AAA x 2
Battery Life *3
(Continuous operation)
48 hrs.
Battery Life *3
(Standby)
1 Year
Operating Temperature
-10°C
60°C
Storage Temperature
-20°C
70°C
Humidity
1
999,0°
0,1°
Data memory size
NAMES AND FUNCTIONS OF PARTS A
LED Indicator
Buzzer
LCD Display
Pre-set angle selection
Up button
Down button
±2° for 90° rotation @ 30°/sec
Pre-setting No
Digital angle value readout
+/-2° accuracy ( rotating 90° at speed of 30°/sec)
CW and CCW operation
Buzzer and LED indicator for the 9 pre-settable target torques
50 data memory for recall and joint torque auditing
Auto Sleep after about 2 minutes idle
Both AAA and rechargeable batteries are compatible
1.
2.
3.
4.
5.
6.
Accuracy *1
Resolution
MAIN FEATURES
•
•
•
•
•
•
•
BEFORE USING THE METER
SCMT26940
POWER ON AND RESETTING THE METER
• Press
to power on the meter.
to reset the meter before using it.
• Usually press
B
Up to 90% non-condensing
Drop Test
1m
Vibration Test *4
10 G
Environmental test *5
Pass
Electromagnetic compatibility
test *6
Pass
2
Note:
*1: The accuracy of the readout is guaranteed from 0.0° to 360.0° and
the test speed is 30°/sec. For maintaining accuracy, calibrate the meter at
regular intervals (1 year recommended).
3
7
4
5
8
*2: Use a special designed cable (accessory) to upload record data to PC.
*3: Use two AAA batteries (Tested condition: Toshiba carbon-zinc R03UG battery)
*4: Horizontal and vertical test
6
*5: Environmental test:
11
a. Dry heat
b. Cold
c. Damp heat
d. Change of temperature
10
e. Impact (shock)
f. Vibration
g. Drop
*6: Electromagnetic compatibility test:
9
a. Electrostatic discharge immunity (ESD)
b. Radiated susceptibility
c. Radiated emission
FAST GETTED START
to power on.
Press
Press
or
to set target angle.
to start the angle measurement.
Press
Start rotation.
Rotation stop and the LCD will be flashing.
Now press
to record angle or
to clear or
press
press
to count from current angle.
The Stanley Works - 82 Taryn Drive
Epping Melbourne - Victoria
Australia 3076
Tel : 0384012000
Sidchrome.com.au
Instruction manual
IM-SCMT26940/1211
POWER ON
Note
1. There are 6 LEDs to indicate the current angle reaching 80%, 85%,
90%, 95%, 97.5% and 99.5% of target angle.
OPERATION
Gently press
●
to power on.
FAST GETTED START
➜ Press
to power on.
or
to set target angle.
➜ Press
to start the angle measurement.
➜ Press
➜ Start rotation.
➜ Rotation stop and the LCD will be flashing.
➜ Now press
to record angle or
press
to clear or
0
Current Target Angle
Press
Note: First the direction sign
or
will show .
Then the LCD shows
. It indicates the meter is under resetting
process. Finally if the reset process is completed, the target angle will be
shown. For example
is shown.
press
Green
Red
99.5% 97.5% 95% 90%
(((((((((..
„„„..))))))))))
●
85%
to select the
●
(Positive) means clockwise direction and
●
1- PUT THE METER ON THE WRENCH
●
The meter will auto power off after about 2 minutes idle for
power saving.
Caution:
appears), the auto power-off
During communication period (
function is disabled.
Pressing
●
ZERO RESET
●
Press
Press
to power on the meter or reset it.
●
Finally the current target angle will be shown.
●
Make sure the direction. If you want to change to direction, please
refer to “CHANGE ANGLE DIRECTION”.
for zero reset
0
Positive direction
Ussually press
to zero reset the digital angle meter before
using the meter. It will guarantee a better accuracy.
Press
●
●
To do hardware rest, use a pin to touch the reset button which is
located in the hole of the meter back.
Another way is remove battery and re-install it.
If the meter does not work functionally, please do hardware reset.
ERROR MESSAGE
0
Low battery indicator
LOW VOLTAGE INDICATOR
If the battery voltage is too low, the meter will display a battery
symbol and then turn off. Replace batteries.
shows that the meter does not work functionally, please do
hardware reset. Refer to “HARDWARE RESET”.
If the meter rotates too fast,
Do press
to zero reset the meter.
will be shown.
●
Start to count angle
from 30.3
Pressing
Flashing
Press
to select the pre-set target angle (M1➜M9).
Or press
or
to modify the current target angle. Note that
the target angle will be saved automatically with the current M number.
Press
to select
target angle
Press
or
to modify target
angle
4- PRE-TIGHTEN WRENCH
Hold on your wrench
to pre-tighten the screw.
(eliminate the backlash of wrench)
●
Pre-tighten
Press
to select the data
or
If no record exists,
will be shown.
CLEAR A SINGLE RECORD
From the current target angle screen, long press
to go into
can visit the direction menu, record
setup menu. Continuously press
menu, record clear-all menu and communication menu. Finally press
again to skip out the setup menu and go back to the current target
angle screen.
●
Visit the record menu
●
Press
or
Press
(
twice to delete the current data.
will be shown)
●
or
0
Current Target Angle
to start the angle meter and immediately pull your wrench.
6- STOP AND WAIT FOR LCD FLASHING
As the angle meter does not move for a few second, the LCD screen
will be flashing and the current angle
is holding on screen.
It also means the meter stop calculating angle.
Flashing
to skip out this menu.
Continuously pressing
will skip out the setup menu and go
back to the current target angle screen.
to select data
Direction
menu
Press
Record
menu
Press
Record
clear-all
menu
Press
to select the data number you want to delete.
Press
or
to select data
Press
Press
Press
Abandon
Press
●
will be shown. If you want to
ATTENTION:
One-year periodic recalibration is necessary to maintain accuracy.
Please contact your local dealer for calibrations.
Show record and data number
5- START TO MEASURE ANGLE
●
or
●
Continuously pressing
will skip out the setup menu and go
back to the current target angle screen.
SET UP MENU INTRODUCTION
●
once,
MAINTENANCE AND STORAGE
●
will record the current value and then clear the current value.
Press
●
abandon, just press
Visit the record menu, press
number and view it.
Press
Flashing
Current Target Angle
If press
will calculate angle again from current angle.
●
If the meter does not reset successfully for a period of time,
will be shown. Press
to do zero-reset again. Notice that
during resetting process, never vibrate or shake the meter. Keep it rest.
Pressing
Abandon
or
●
Press
3- SET TARGET ANGLE
HARDWARE RESET
●
0
Current Target Angle
Press
●
Caution:
1.During resetting process, never vibrate or shake the meter. Keep it rest.
shows. Refer to ‘‘ERROR MESSAGE’’ section.
2.If
●
Press
●
Flashing
●
twice to delete the all record data.
will be shown)
Press
VIEW ANGLE RECORD
Press
2- POWER ON THE METER AND RESET
Press
(
Press
●
will clear the current angle.
Visit the record clean-all menu
●
After setting the direction, continuously press
to skip out
the setup menu and go back to the current target angle screen.
➜ over 99.5 %
7- CLEAR ANGLE VALUE or
CALCULATRING ANGLE AGAIN or
SAVE ANGLE RECORD
AUTO POWER OFF
or
(negative) is counter-clockwise direction.
80%
0
Caution:
During resetting process, never vibrate or shake the meter. Keep it rest.
CLEAR ALL RECORDS
Visit the direction menu, press
direction.
2. There is also a buzzer to indicate the reaching level of target angle.
Interval sound means it reaches over 80% and long sound means it
reaches over 99.5% of target angle.
((..((..((.. „„„..))..))..))..)) ➜ over 80 %
to count from current angle.
CHANGE ANGLE DIRECTION
●
If press
abandon, just press
once,
will be shown. If you want to
to skip out this menu.
Press
Communication menu
●
Continuously pressing
will skip out the setup menu and go
back to the current target angle screen.
CAUTION:
1- Do not shake violently or drop meter.
2- Do not leave this meter in any place exposed to
excessive heat, humidity, or direct sunlight.
3- Do not use this apparatus in water.(it is not waterproof)
4- If the meter gets wet, wipe it with a dry towel as soon as possible. The
salt in seawater can be especially damaging.
5- Do not use organic solvents, such as alcohol or paint thinner when
cleaning the meter.
6- Keep this meter away from magnets.
7- Do not expose this meter to dust or sand as this could cause serious
damage.
8- Do not apply excessive force to the LCD panel.
BATTERY MAINTENANCE
1- When the meter is not going to be used for an extended period of
time, remove the batteries.
2- Keep a spare battery on hand when going on a long trip or to cold
areas.
3- Do not mix battery types or combine used batteries with new ones.
4- Sweat, oil and water can prevent a battery’s terminal from making
electrical contact. To avoid this, wipe both terminals before loading a
battery.
5- Dispose of batteries in a designated disposal area. Do not throw
batteries into a fire.
Download PDF