LG | S09AHP4 | LG S09AHP Owner’s Manual

website
http://www.lgservice.com
LG
LG
Room Air Conditioner
OWNER'S MANUAL
IMPORTANT
?
Please read this owner's manual
before
?
installing
and
carefully
operating your
room
and
thoroughly
air conditioner.
Please retain this owner's manual for future reference after
reading
it
thoroughly.
Room Air Conditioner Owner's Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety
Precautions.........................3
Write the model and serial numbers here:
Model #
Prior to
Operation
..........................9
Serial #
You
can
find them
label
on a
on
the side of each unit.
Dealer's Name
Introduction ..................................10
Date Purchased
Staple
it to prove
Electrical
Operating
Safety
receipt to this page in the event you need
date of purchase or for warranty issues.
your
...........................11
Instructions.................12
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive
care on
of time and money
Maintenance and Service ............26
your
over
you a great deal
the life of your air conditioner.
part
can save
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first,
you may not need to call
for service at all.
PRECAUTION
?
Contact the authorized service technician for
or
Contact the installer for installation of this unit.
?
The
?
?
?
Room Air Conditioner
maintenance of this unit.
?
?
2
repair
appliance
is not intended for
by young
children or infirm persons without supervision.
Young Children should be supervised to ensure that
they do not play with appliance.
When the power cord is to be replaced, replacement
work shall be performed by authorized personnel
only using only genuine replacement parts.
Installation work must be performed in accordance
with the National Electric Code by qualified and
authorized personnel only.
If the appliance is supplied from a cord extension set
or an electrical portable outlet device, the cord
extension set on electrical portable outlet device
must be positioned so that it is not subject to
splashing or ingress of moisture.
use
Safety Precautions
Precautions
Safety
To
prevent the injury of the
user or
other
people
and
property damage, the following instructions
must be
followed.
Incorrect
by
operation due to ignoring
following indications.
the
The
meanings
of the
instruction will
cause
harm
or
damage.
This
symbol
indicates the
possibility of
This
symbol
indicates the
possibility of injury or damage
symbols
used in this manual
are as
Be
Be
sure
death
The seriousness is classified
or
serious
injury.
to
properties only.
shown below.
sure
not to do.
to follow the instruction.
Installation
Do not
For electrical
the power plug
and socket with the ground
work, contact
the dealer, seller, a qualified
electrician, or an Authorized
damaged power
cords, plugs, or a loose
use
socket.
Always
use
terminal.
Service Center.
?
There is risk of fire
or
electric
?
shock.
or
electric
?
panel
and the
Do not
of control box
modify
or
extend the
Do not
There is risk of fire
shock.
install,
remove,
re-install the unit by
power cord.
securely.
?
There is risk of electric shock.
shock.
Install the
cover
There is risk of fire
or
yourself (customer).
or
electric
?
There is risk of fire
shock.
or
electric
?
There is risk of
fire, electric
shock, explosion,
or
injury.
Owner's Manual
3
Safety Precautions
Be cautious when
For
unpacking and installing
the product.
contact the dealer
Sharp edges could cause injury.
Be especially careful of the
case edges and the fins on the
?
condenser and
Be
sure
?
There is risk of
on a
or
product
defective installation
stand.
?
injury.
It may
injury, accident,
damage to the product.
cause
or
evaporator.
the installation
Do not let the air conditioner
area
run
age.
humidity
collapses,
the air
?
conditioner could fall with
it, causing
property damage, product failure,
and
fire, electric
shock, explosion,
does not deteriorate with
If the base
or an
Authorized Service Center.
for
door
?
Do not install the
installation, always
or
a
long
time when the
is very high and a
a window is left open.
Moisture may condense and
wet
or
damage furnishings.
personal injury.
Operation
Take
care
to
ensure
that
Do not
power cords could not be
place anything
Do not turn the
on
the power cord.
air-conditioner ON
pulled out or damaged
during operation.
?
There is risk of fire
or
electrical
shock.
4
Room Air Conditioner
or
OFF
by plugging or unplugging
the power plug.
?
There is risk of fire
shock.
or
electric
?
There is risk of fire
shock.
or
electrical
Safety Precautions
?
Use
a
dedicated outlet for
this
appliance.
There is risk of fire
or
electrical
Grasp the plug
?
shock.
the cord from the outlet. Do
place a heater or
other appliances near the
not touch it with wet hands.
power cable.
to
There is risk of fire
Do not
remove
electrical
or
?
shock.
Do not allow water to
into electric
shock.
Do not store
run
Donotusetheproductina
tightly closed space for a
long time.
or use
flammable gas or
combustibles near the air
parts.
There is risk of fire and electric
conditioner.
?
It may cause There is risk of
fire, failure of the product, or
?
There is risk of fire
or
failure of
?
Oxygen deficiency
could
occur.
product.
electric shock.
Wax
When flammable gas leaks,
turn off the gas and open a
sounds, odors,
window for ventilation
comes
the unit if
or
and close
strange
Stop operation
smoke
the window in storm
from it.
hurricane. If
or
possible,
before turn the
remove
DO NOT
from the window before the
or
?
Unplug
Thinner
product on.
use the telephone
turn switches
There is risk of
on or
explosion
off.
or
fire.
the air conditioner
hurricane arrives.
?
There is risk of electrical shock
or
fire
?
There is risk of
damage,
property
failure of
product,
or
electric shock.
Owner's Manual
5
Safety Precautions
Do not open the inlet
the product during
is
?
so
of
When the
product is soaked
(flooded or submerged),
not touch the
operation. (Do
electrostatic
grill
contact
filter, if the unit
an
Ventilate the
product from
time to time when operating
it together with a stove, etc.
Authorized
Service Center.
equipped.)
There is risk of
electric
physical injury,
shock, or product
?
There is risk of fire
or
eletric
?
shock.
There is risk of fire
or
electrical
shock.
failure.
Unplug the appliance before
performing cleaning or
When the
product is not be
used for a long time,
disconnect the power supply
plug or turn off the breaker.
maintenance.
?
There is risk of electrical shock.
?
There is risk of
or
failure,
or
product damage
Take
care
nobody
to
ensure
could
step
that
on or
onto the outdoor unit.
?
unintended
This could result in
injury
and
personal
product damage.
operation.
Installation
Always check for gas
(refrigerant) leakage after
installation or repair of
product.
?
Low
refrigerant
cause
failure of
levels may
product.
Install the drain hose to
ensure
away
?
that water is drained
properly.
A bad connection may
water
Keep level even when
installing the product.
leakage.
cause
?
To avoid vibration
or
leakage.
90˚
6
Room Air Conditioner
water
fall
Safety Precautions
Do not install the
where the noise
Use two
product
or
hot air
lift and
from the outdoor unit could
damage
?
It may
the
or more
people
Do not install the
to
product
where it will be exposed to
sea wind (salt spray)
directly.
transport the air
conditioner.
neighborhoods.
cause a
problem
for your
?
Avoid
personal injury.
?
It may
cause
corrosion
on
the
product. Corrosion, particularly
neighbors.
the condenser and
could
or
on
evaporator fins,
product malfunction
inefficient operation.
cause
Operation
Do not direct airflow at
room
occupants. (Don't sit
in the
draft.)
Do not
use
the
product for
Do not block the inlet
special purposes, such as
preserving foods, works of
art, etc. It is
a consumer
conditioner,
not
a
or
outlet of air flow.
air
precision
refrigeration system.
?
This could
damage
your health.
?
There is risk of
of
Use
not
a
soft cloth to clean. Do
use
harsh
solvents,
?
detergents,
or
loss
?
fire, electric
shock, or damage to the plastic
parts of the product.
?
It may
cause
product failure.
property.
Do not touch the metal
Do not
parts of the product when
anyting on the product.
(outdoor units)
removing the air filter. They
are very sharp!
etc.
There is risk of
damage
There is risk of
personal injury.
?
step
on or
put
There is risk of
and failure of
personal injury
product.
Owner's Manual
7
Safety Precautions
Always insert the filter
securely. Clean the filter
every two weeks or
often if necessary.
A
objects through
more
or
filter reduces the
dirty
efficiency
?
Do not insert hands
and could
Use
a
There
and
product
or damage.
maintaining
ladder when
or
drained from the unit.
are
sharp
parts that could
in.
moving
cause personal
?
It is not
cause
sanitary
and could
serious health issues.
injury.
cause
firm stool
Do not drink the water
outlet while the air
plugged
?
other
the air inlet
conditioner is
of the air conditioner
malfunction
or
cleaning
or
the air conditioner.
Replace the
all batteries in the remote
control with
new ones
not mix old and
new
of the
same
batteries
or
type. Do
different
types of batteries.
Be careful and avoid
?
personal injury.
?
Thereisriskoffireorexplosion
Disuse
Do not
recharge
or
batteries. Do not
disassemble the
dispose
of batteries in
If the
liquid
from the batteries
gets
onto
your skin or clothes, wash it well with clean
water. Do not use the remote if the batteries
a
fire.
have leaked.
?
They
may burn
or
explode.
?
The chemicals in batteries could
other health hazards.
8
Room Air Conditioner
cause
burns
or
Prior to
Prior to
for
Preparing
1. Contact
2.
Operation
Operation
installation
in the power
Plug
3. Use
an
Operation
specialist
plug properly.
for installation.
dedicated circuit.
a
4. Do not
use an
extension cord.
5. Do not
6. If the
start/stop operation by plugging/unplugging the power cord.
cord/plug is damaged, replace it with only an authorized replacement part.
Usage
1.
Being exposed
to direct airflow for
3.
Cleaning
or
and Maintenance
1. Do not touch the metal
2. Do not
3.
long
plants
Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with
stoves or other heating devices.
Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices,
food, pets, plants, or art objects). Such use may damage your properties.
occupants, pets,
2.
time may be hazardous to your health. Do not expose
to direct airflow for a long time.
a
use
parts of the unit when removing the filter. Injury
water to clean inside the air conditioner.
Exposure
to water
can occur.
can
destroy
the
insulation,
leading to electric shock.
When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at
very high speed during operation. There is a possibility of injury if the unit's power is triggered while
cleaning inner parts of the unit.
a
Service
For
repair and maintenance,
OPERATING
contact your authorized service dealer.
TEMPERATURE(°C)COOLING
MODE
INDOOR
MAX.
OUTDOOR
MIN.
MAX.
MIN.
32°C2 1 °C4 3 °C2 1 °C
HEATING MODE
INDOOR
MAX.
OUTDOOR
MIN.
MAX.
MIN.
27°C2 0 °C2 4 °C1 °C
Owner's Manual
9
Introduction
Introduction
Symbols
used in this Manual
This
symbol
This
symbol
This
symbol
alerts you to the risk of electric shock.
alerts you to hazards that may
air conditioner.
NOTICE
indicates
special
cause
harm to the
notes.
Features
This
appliance should be installed in accordance
guide to help to explain product features.
with national
wiring regulations.
This
acts
guide
as a
Indoor
Air Inlet
Air Filter
Front Panel
Signal Receptor
Outdoor
Air Intake Vents
Connecting
Wires
Piping
Air Outlet Vents
Base Plate
10
Room Air Conditioner
Drain Hose
Electrical
Electrical
?
This
appliance
must be
Safety
properly grounded.
To minimize the risk of electric
?
?
?
Safety
alway plug into a grounded oulet.
Do not cut or remove the grounding prong from the power plug.
Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance
unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the
house wiring.
If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and
circuit checked by a qualified electrician.
Temporary
shock, you
Use of an
must
Adapter
We
strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,
use only a UL-listed adapter, available from most local hardware stores. Ensure that the large slot in the
adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
?
Never
use
the
appliance
Temporary
with
a
broken
adapter.
Use of an Extension Cord
We
strongly discourage the use of an extension cord due to potential safety hazards. For temporary
situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.
Owner's Manual
11
Operating
Instructions
Instructions
Operating
How to insert the Batteries
1. Remove the
2. Insert
new
installed
by pulling it according to the arrow direction.
making sure that the (+) and (-) of battery are
battery
cover
batteries
correctly.
3. Reattach the
cover
by sliding
it back into
position.
NOTICE
Use 2
Do
AAA(1.5volt) batteries.
not use rechargeable batteries.
Storage
?
and
Tips for using the Remote Controller
The remote controller may be stored
itonawall.
by mounting
?
To
operate the
conditioner, aim the
the signal receptor.
room
remote controller at
air
Signal Receptor
Receives the
signals from
the remote
Indication
Operation
On/Off
DOOR
during
:
Lights
up
during Sleep
Timer
:
Lights
up
during
Defrost Mode
:
Lights up during Defrost Mode or *Hot
Start operation (Heat pump model only)
OUTDOOR UNIT
:
Lights up during outdoor
(Cooling model only)
OPERATION
Display
Plasma
dehumidification
Shape of
display
Setting
temp.
12
Timer
Mode Auto
unit
The function illustrates its
Room Air Conditioner
Too hot
operation.
setting temperature
A.I
operation
Hot
indoor fan in
operation.
Operation indicating
lamps
:
operation: Stops the
long beep.)
operation.
Indicates the
Standard
or one
system operation.
:
Cooling
heating
indicator
*Hot Start
the
up
Mode
beeps
Lamps
Lights
Power
Operation
sound: two short
:
Sleep
OUT
control.(Signal receiving
and
dynamic
operation
mode
mode.
by using
mode
Comfortable
a
multiple lighting system.
Jet
Cold
Heating Operation
to
Too cold
Test
(Cool, Heat) operation
prevent cold air from blowing
out from unit.
Operating
Remote Control
The controls will look like the
Instructions
Operations
following.
Controls
Signal
transmitter
1. START/STOP BUTTON
Operation starts when this button is pressed
and stops when the button is pressed again.
2. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3. ROOM TEMPERATURE SETTING
BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high and CHAOS.
5. JET COOL
Used to start
stop the speed cooling.(speed
cooling operates super high fan speed in
5
or
cooling mode.)
1
6. CHAOS SWING BUTTON
Used to stop or start louver movement and
set the desired up/down airflow direction.
6
3
7. ON/OFF TIMER BUTTONS
Used to set the time of starting and
4
operation. (See
10
2
CANCEL
ON
SET
OFF
12
AUTO CLEAN
11
13
operation. (See
14
page
22)
10. SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
16
15
22)
9. TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time
is obtained and to cancel the Timer
17
8
22)
8. TIME SETTING BUTTONS
Used to adjust the time. (See page
9
7
page
stopping
(See
page
22)
11. AIR CIRCULATION BUTTON
Used to circulate the room air without
cooling
Flip-up door
(opened)
Operation
Mode
Operation
Healthy
or
Auto
Cooling Model(
),
Heat
Operation
Pump Model(
23)
12. ROOM TEMPERATURE CHECKING
BUTTON
Used to check the room temperature.
(See
page
20)
15. RESET BUTTON
Used prior to resetting time.
16. 2nd F Button
Used prior to using modes printed in blue
at the bottom of buttons. (See page 21)
Heating Operation
?
page
14. HORIZONTAL AIRFLOW DIRECTION
CONTROL BUTTON (OPTIONAL)
Used to set the desired horizontal airflow
direction.
Changeover
Dehumidification
heating. (See
13. NEO PLASMA(OPTIONAL)
Used to start or stop the
plasma-purification function.
Cooling Operation
Auto
or
)
17. AUTO CLEAN (OPTIONAL)
Used to set Auto Clean mode.
Owner's Manual
13
Operating
Instructions
Cooling operation
1
2
Press the
Start/Stop button.
The unit will respond with
a beep.
Open the door of the remote controller. To select Cooling
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shiftedinthedirectionofthearrow.
Auto
Cooling
Healthy
Dehumidification
Changeover
3
(Heat pump model only)
Close the door of the remote controller. Set the
lower than the
set within
a
room
Set the fan
temperature
temperature. The temperature can be
range of 18°C~30°Cat intervals of 1°C.
ON
4
Heating
To raise the
temperature
To lower the
temperature
speed again
with the door
of the remote controller still closed.
You
speed in four
steps-low, medium, high and CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
Natural wind by the CHAOS
For fresher
blows like
14
a
feeling,
Room Air Conditioner
select the fan
logic
press the Indoor fan
natural breeze
can
speed selector and set to CHAOS
by automatically changing fan speed according
mode. In this
mode, the wind
to the CHAOS
logic.
Operating
Auto
Instructions
operation (Optional)
Press the
1
Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Auto
Operation, press the operation mode selection button.
Eachtimethebuttonispressed,theoperationmodeis
shiftedinthedirectionofthearrow.
Cooling
ON
3
The
Auto
Healthy
Dehumidification
temperature and fan speed
electronic controls based
on
are
Heating
(Heat pump model only)
automatically
the actual
room
set
by
the
temperature. If
change the set temperature, press the Room
Temperature Setting buttons. The cooler or warmer you feel,
themoretimes(uptotwotimes)youshouldpressthebutton.
The set temperature will be changed automatically.
you want to
To raise the
temperature
To lower the
temperature
During Auto Operation
You cannot control the indoor fan
already been set by the Fuzzy rule.
If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating mode to cooling
mode, it must be done by manually resetting.
During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the chaos swing button again.
speed.
It has
Owner's Manual
15
Operating
Auto
Instructions
changeover operation(Optional)
Press the
1
Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Auto Changeover
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted in the
direction of the
arrow.
Cooling
3
Auto
Healthy
Changeover
Dehumidification
Heating
(Heat pump model only)
Close the door of the remote controller. Set the
lower than the
set within
a
room
temperature
temperature. The temperature can be
range of 18°C~30°Cat intervals of 1°C.
To raise the
temperature
To lower the
temperature
ON
4
Set the fan
speed again
with the door
of the remote controller still closed.
You
speed in four
steps-low, medium, high and CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
During Auto changeover Operation
The air conditioner changes the operation
temperature vary over
temperature within ±2°C
16
select the fan
automatically to keep indoor temperature. When
±2°C with respect to setting temperature, air conditioner keeps the
with respect to setting temperature by auto changeover mode.
Room Air Conditioner
mode
can
room
room
Operating
Healthy
dehumidification
Instructions
operation
Press the
1
Start/Stop button.
The unit will respond with
a beep.
2
Open
the door of the remote controller. To select
Dehumidification
Operation,
press the
Healthy
Operation Mode
Selection button.
Each time the button is
pressed,
shifted in the direction of the
3
operation
mode is
arrow.
Auto
Healthy
Heating
Changeover
Dehumidification
(Heat pump model only)
Cooling
Set the fan
the
speed again
with the door
of the remote controller still closed.
You
speed in four
steps-low, medium, high, or CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
ON
can
select the fan
Natural wind by the CHAOS
For fresher
feeling,
logic
press the Indoor Fan
to CHAOS mode. In this
breeze
Speed
Selector and set
mode, the wind blows like
by automatically changing
CHAOS logic.
fan
a
speed according
natural
to the
During Healthy Dehumidification Operation
If you select the dehumidification mode on the operation selection button, the product starts to run the
dehumidification function. It automatically sets the room temp. and airflow volume to the best condition
for
dehumidification, based
on
In this case, however, the setting
control the room temp. either.
the sensed current
temp. is
not
room
displayed
temp.
on
the remote controller and you
are
not able to
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status, so that the room condition is kept
healthy and comfortable even in the very humid season.
Owner's Manual
17
Operating
Instructions
Heating operation (Heat
pump model
only)
Press the
1
Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote controller. To select Heating
Operation, press the Operation Mode Selection button.
Eachtimethebuttonispressed,theoperationmodeis
shiftedinthedirectionofthearrow.
Auto
Cooling
Healthy
Dehumidification
Changeover
3
Heating
(Heat pump model only)
Close the door of the remote controller.
Set the
temperature higher than the room temperature.
The temperature can be set within a range of 16°C~30°Cat
intervals of 1°C.
ON
4
Set the fan
To raise the
temperature
To lower the
temperature
speed again
with the door of the
remote controller still closed. You
select the fan
speed
in four
can
steps--low,
medium, high and CHAOS. Each time the
button is
pressed,
the fan
speed
mode is
shifted.
Natural wind
For fresher
by the CHAOS logic
feeling,
wind blows like
18
a
press the Indoor Fan
natural breeze
Room Air Conditioner
Speed Selector and set to CHAOS
by automatically changing fan speed according
mode. In this
to the CHAOS
mode, the
logic.
Operating
Jet cool
Instructions
operation
Press the
1
Start/Stop button.
The unit will respond with
a beep.
2
Press the Jet Cool button to
the
speed cooling
will
operate
on
3
cooling
operate
mode and the unit
at super
high
fan
speed
mode for 30 minutes.
To cancel the Jet Cool
mode, press the Jet Cool button, the
fan speed button or the room temperature setting button
again and the unit will operate at high fan speed on cooling
mode.
or
or
NOTICE
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely
high speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to
cool the room temp. quickly in a hot summer.
In heat pump mode
or
auto
changeover mode, however,
In order to return to the normal
mode selection
cooling
the JET COOL function is not available.
mode from the JET COOL
mode, just press the operation
button, airflow volume selection, temp. setting button
or
the JET COOL button
again.
Owner's Manual
19
Operating
Instructions
NEO PLASMA
purification operation(Optional)
Press the
1
Start/Stop button.
Theunitwillrespondwitha
beep.
2
Open
the door of the remote
controller. Press the PLASMA
button.
Operation will start when the button
is pressed and stop when the button
is pressed again.
3
Set the fan
speed again
controller closed. You
with the door of the remote
can
select the fan
speed
in four
steps-low, medium, high or CHAOS.
Each time the button is pressed, the fan
speed mode is shifted.
Air
purifying operation (NEO PLASMA) can be
with cooling, Heating or any other operations.
NEO PLASMA Air
Purifying Operation only
If you press the only PLASMA button, only
PLASMA purification function operates.
Then, fan speed is low. You can select the fan
speed in four steps-low, medium, high or
CHAOS.
Each time the Indoor Fan
button is
shifted.
20
Room Air Conditioner
pressed,
the fan
Speed Selector
speed mode is
Operating
2nd F
Instructions
operation
Press the
1
Start/Stop button.
The unit will respond with
a beep.
2
Open
the door of the remote controller and press the 2nd
Function button to operate functions printed blue color under
buttons.
(Check the indication
remote controller.)
of 2nd function
on
the
display of the
CANCEL
ON
OFF
SET
AUTO CLEAN
3
For
2nd function
the button is
more
disappears in a
pressed again.
short time
details, refer to functions
automatically or when
next pages.
Owner's Manual
21
Instructions
Operating
Additional Features
Sleep
1. Press the
mode
Mode Auto button to set the time you want the unit to
Sleep
2. The Timer is
in one-hour increments
programmed
mode is available for 1 to 7 times. To
sleep
stop automatically.
by pressing the Sleep Mode Auto button 1 to 7 times. The
alter the time period in steps of 1 hour, press the Sleep Mode
Button while
3.
aiming at air conditioner.
Make sure the Sleep Mode Auto LED lights up.
To cancel the Sleep Mode, press the sleep Mode
(
) disappears from the operation display.
Auto button several times until the star
NOTICE
The
a
Sleep
Mode will be
comfortable
operated
at slow fan
speed (cooling)
or
medium fan
speed (heat
pump
only)
for
sleep.
In
cooling mode or healthy dehumidification mode:
The setting temperature will automatically rise by 1°C over the
sleep.
by 2°C
in 1 hour for
a
comfortable
the time
Setting
1. Time
next 30 minutes and
be set
you press the Reset button. Having replacing the batteries,
you should press the reset buttons to reset the time. Press the Start/Stop button.
can
only when
2. Press 2nd F button and check if 2nd F icon is
3. Press the Time
Setting
on.
buttons until the desired time is set.
CANCEL
4. Press the Timer SET button.
SET
NOTICE
Check the indicator for A.M. and P.M.
Delay
1. Make
sure
start/Pre-set
the time is set
stop
the
correctly on
display
of the remote controller.
2. Press 2nd F button.
3. Press the ON/OFF Timer buttons to turn Timer
4. Press the Time
Setting
on or
off.
ON
OFF
buttons until the desired time is set.
CANCEL
5. To set the selected
time, press the Timer setting button aiming the
remote controller at the
SET
signal receptor.
To cancel the timer
setting
Checkif2ndFiconisoff.
CANCEL
Press the Timer Cancel button
(The timer lamp
on
aiming
the remote controller at the
the air conditioner and the
display will
go
signal receptor.
SET
out.)
NOTICE
Select
one
Delay
22
of the
following
four
OFF Timer
Room Air Conditioner
types
Delay
of
with the unit
operation.
ON Timer
Delay
OFF and ON Timer
running
Delay
ON and OFF Timer
Operating
Instructions
Vertical Airflow Direction Control
The
up/down airflow (Vertical Airflow)
adjusted by using the remote control.
can
be
NOTICE
If you press the Chaos
1. Press the
Start/Stop
2. Press Chaos
Swing
Swing button, the
horizontal airflow direction is changed
automatically based on the CHAOS algorithm to
distribute the air in the room evenly and at the
same time to make the human body feel most
comfortable, as if enjoying a natural breeze.
Always use the remote control to adjust the
up/down airflow direction. Manually moving the
vertical airflow direction louver by hand, could
damage the air conditioner.
When the unit is shut off, the up/down airflow
button to start the unit.
button and the louvers will
up and down. Press the Chaos Swing
button again to set the vertical louver at the
swing
direction louver will close the air outlet vent of
the
desired airflow direction.
Horizontal Airflow Direction Control
system.
(Optional)
The
left/right(Horizontal Airflow) can be adjusted by using the remote control.
Press the Start/Stop button to start the unit.
Open the door on the remote control. Press the Horizontal Airflow Direction
button and the louvers will swing left and right. Press the Horizontal Airflow
Direction Control Button again to set the horizontal louver at the desired airflow
direction.
Air circulation mode
Circulates the
1. Press the
2.
Open
room
air without
Start/Stop
the door
on
cooling
or
heating.
button. the unit will
respond
with
a
beep.
the remote control. Press the Air Circulation button. Close the door
Now each time that you press the Indoor Fan
CHAOS and back to low again.
CHAOS Air
Speed
Fan
speed
on
the remote control.
Selector
button, the fan speed is shifted from low
is
Fan
on
low.
speed
is
on
medium.
Fan
speed
is
on
to
high.
NOTICE
CHAOS Air economizes power
changed
from
high
to low
or
consumption and prevents overcooling. The fan speed
vice versa, depending on the ambient temperature.
is
automatically
Owner's Manual
23
Operating
Instructions
Auto clean
(Optional)
1. Whenever you press the AUTO CLEAN
reserved and cancelled.
AUTO CLEAN
button, Auto Clean Function will be
2. Auto Clean function works before and after
For
details, refer
to the below
cooling
or
dehumidification mode.
points.
3. When the unit is started after the reservation of Auto Clean
function
operates and indoor Fan is started after
,the Cool Start
20 seconds.
4. When you press Start/Stop button to turn off the unit after the you have reserved
Auto Clean function, the air-conditioner circulates the indoor air in the Auto
Clean mode with
no more
Cooling
or
Dehumidification
operation.
It lasts for 30
minutes.
5. If you press the AUTO CLEAN button
Clean function will be cancelled.
again during
the
product operation
,
Auto
NOTICE
During
Auto Clean
Dehumidification
During
function, moistures left in indoor units after Cooling Operation
Operation
Auto Clean
can
or
Healthy
be removed.
function, only Start/Stop button, Plasma button and AUTO CLEAN button
are
available.
Forced
operation
Operation procedures when the remote control can't be used.
The operation will be started if the ON/OFF button is pressed.
If you want to stop operation, re-press the button.
ON/OFF
button
Cooling
Heat pump Model
Model
Room Temp. ≥ 24°C2 1 °C ≤ Room Temp.
<
24°C
Room
Temp. < 21°C
Operating
mode
Cooling
Cooling
Healthy Dehumidification
Heating
Indoor FAN
Speed
High
High
High
High
22°C2 2 °C2 3 °C2 4 °C
Setting Temperature
Test
operation
During
the TEST
temperature and
OPERATION, the unit operates in cooling mode
use
if remote controller
this
operation,
signal
is
received, the unit operates
24
of
room
stop the operation, re-press the button.
Room Air Conditioner
as
remote controller sets.
Press and hold the ON/OFF button for 3~5seconds, then the buzzer sound 1
"beep".
If you want to
high speed fan, regardless
resets in 18 minutes.
During test operation,
If you want to
at
Operating
Instructions
Auto restart
In
again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
case
the power
Helpful
comes on
information
Fan
speed and cooling capacity.
The cooling capacity indicated in the specification is the value
when the fan speed is set to high, and the capacity will be lower
at low or medium fan speed.
High fan speed is recommended when you wish to cool the room
quickly.
High
Speed
NOTICE
Auto restart function has set enable
But customer
can
set up
as
by following
factory default.
this instruction.
To be disable function
-
Press and hold the ON/OFF button for 6
seconds, then the buzzer sound
2
"beep"
and the indicator
lamp (1)
seconds, then the buzzer sound
2
"beep"
and the indicator
lamp (1)
blinks 4 times.
To be enable function
-
Press and hold the ON/OFF button for 6
brights
4 times.
Owner's Manual
25
Maintenance and Service
Maintenance and Service
Before
performing
any
maintenance,
turn off the main power to the
system.
Indoor Unit
Grille, Case, and Remote Control
Turn the
system off before cleaning. To clean, wipe with
cloth. Do not
use
bleach
or
a
soft, dry
abrasives.
NOTICE
Supply
power must be disconnected before
the indoor unit.
cleaning
Air outlet vent
Air filters
(behind front
panel)
Vertical louver Horizontal louver
Air filters
The air filters behind the front
cleaned
Air inlet vent
should be checked and
grille
in every 2 weeks or more often if neccessary.
1. Pull the both sides and remove front panel.
once
2. Pull the filter tab
slightly forward
3. Clean the filter with
a vacuum
to
remove
cleaner
or
the filter.
warm, soapy water.
If dirt is
conspicuous, wash with a solution
detergent in lukewarm water.
If hot water (40°C or more) is used, it may
?
?
of
be
deformed.
4. After
with water,
5. Re-install the air filter.
dry well
washing
NEO PLASMA filter
in the shade.
(Optional)
The NEO PLASMA filter behind the air filters should be
checked and cleaned
once
in every 3 months
often if
or more
necessary.
1. After
removing
the air
filters, pull slightly forward
to
remove
the NEO PLASMA filter.
2. Clean NEO PLASMA filter with the
vacuum
cleaner.
If it is very dirty, wash it with water.
3. Note the cuts of electric discharge lines.
4. Re-install the NEO PLASMA filter to the
TRIPLE DEODORIZER filter
1. After
removing
the air
TRIPLE
DEODORIZING
Filter
NEO PLASMA
Filter
original position.
(Optional)
filters, pull slightly forward
to
remove
the TRIPLE DEODORIZER filter.
2.
Dry
in the
sunlight for two
hours.
3. Re-install the TRIPLE DEODORIZER filter to the
original
position.
Don't touch this NEO PLASMA Filter within 10 seconds after
it may
Never
?
?
26
cause an
opening
he inlet
grille,
electric shock.
any of the followings:
Water hotter than 40°C
Could cause deformation and/or discoloration.
use
Volatile substances
Could damage the surfaces of the air conditioner.
Room Air Conditioner
Powder
Gasoline
Maintenance and Service
Replacement of purifying
Recomended
period
use
1. Remove front
panel
:
filter
(Optional)
About 2 years
and air filters.
Air filter
2. Remove air
3. Insert
new
purifying
air
filters.
purifying
TRIPLE
DEODORIZING
Filter
filters.
2
3
4. Reinsert air filters and close front
panel.
Outdoor Unit
The heat
exchanger coils and panel vents of the outdoor
If clogged with dirt or soot, the heat exchanger
and panel vents may be professionally steam cleaned.
unit should be checked
regularly.
NOTICE
Dirty
or
clogged
coils will reduce the
operating efficiency
of the
system and
cause
higher operating
costs.
Air Intake Vents
Connecting
(Rear)
Wires
Air intake
vents
Piping
Drain Hose
Piping
Drain Hose
(Side)
Air outlet
vents
Air Outlet Vents
Base Plate
Owner's Manual
27
Maintenance and Service
Common Problems and Solutions
Before
calling
for service
If you have problems with your air conditioner, read the following information and try to solve
the problem. If you cannot find a solution, turn off the air conditioner and contact your dealer.
Air conditioner does not
operate
1. Ensure that the air conditioner is
2. Check the fuse
or
plugged
into
a
proper outlet.
circuit breaker.
3. Check whether the
voltage
is
unusually high
or
low.
Air does not feel cold
1.
2.
enough on the cooling setting
Ensure that the temperature settings are correct.
Check to see if the air filter is clogged with dust. If so, replace
the filter.
3. Ensure that the air flow from the outside is not obstructed and that there is
over
20" between the back of the air conditioner and the wall
4. Close all doors and windows and check for any
Before
calling
for
source
or
a
clearance of
fence behind it.
of heat in the
service, please review the following list of
room.
common
problems
and
solutions.
The air conditioner is
?
You hear
pinging
noise. This is caused
in
by water being picked up by
feature is designed to help remove
the fan
on
rainy days
moisture in the air
highly humid conditions. This
and improve cooling efficiency.
You see water dripping from the rear of the unit. Water may be collected in the base pan
highly humid conditions or on rainy days. This water overflows and drips from the rear of
or
?
a
operating normally when:
the unit.
?
You hear the fan
running
feature.
28
Room Air Conditioner
while the compressor is silent. This is
a
normal
operational
in
Maintenance and Service
Troubleshooting
The air conditioner may be
when:
operating abnormally
Possible Causes
Problem
The air conditioner is
What To Do
?
unplugged.
?
the air conditioner
plug
is
into the outlet.
Check the house fuse/circuit breaker
box and
tripped.
Air
sure
pushed completely
The fuse is blown/circuit
breaker is
Make
replace
the fuse
or
reset the
breaker.
conditioner
does not start
Power failure.
?
If power failure occurs, turn the mode
control to Off.
When power is restored, wait 3
minutes to restart the air conditioner
to
prevent tripping of the compressor
overload.
Airflow is restricted.
?
Make
sure
blinds,
or
there
are no
furniture
curtains,
blocking
the front of
the air conditioner.
The air filter is
dirty.
?
Air
Clean the filter at least every 2 weeks.
See the care and Maintenance
section.
conditioner
does not cool
as
it should
The
room
may have been
?
hot.
When the air conditioner is first turned
on, you need to allow time for the
room to cool down.
Cold air is
Cooling
escaping.
coils have iced up.
?
Check for open furnace floor
and cold air returns.
?
See Air Conditioner
registers
Freezing Up
below.
*
You
can
refer to the
Energy
Star program in detail at
www.energystar.gov.
Owner's Manual
29
Memo
30
Room Air Conditioner
P/No.: 3828A24010A
Download PDF