LG | PQCSB101S0 | LG PQCSB101S0.ENCXLEU Owner’s Manual

ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
OWNER’S MANUAL
AIR CONDITIONER
DEUTSCH
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : Simple Central Controller
P/NO : 3828A20467B
www.lg.com
РУССКИЙ ЯЗЫК
MODEL : PQCSB101S0
Central Control Unit
TABLE OF CONTENTS
■ Safety precautions ..................................................................3
■ Before use................................................................................5
System drawing ........................................................................5
Name of each part ....................................................................6
■ Operation tips..........................................................................7
Individual operation...................................................................7
Total control for each group ......................................................7
Total On/Off operation...............................................................7
Mode change ............................................................................8
Setting individual lock ...............................................................9
Setting total lock .......................................................................9
Connected indoor unit search function ...................................10
Self diagnosis for indoor unit ..................................................11
Set group inquiry ....................................................................11
Function controller connection................................................12
2 Simple Central Controller
Safety Precautions
Safety Precautions
• The installation requires expert skills, and it should be installed by the service center or other shops specialized
in the installation and recognized by our company.
• The following safety cautions are provided to prevent unexpected dangers or losses.
WARNING : If the user does not follow the mandatory items, it may result in serious injury or death.
CAUTION : If the user does not follow the mandatory items, it may cause personal injury or property
damage.
: Warning and Caution are to call the user’s attention to the possible danger. Read and follow
them carefully in order to prevent a safety accident.
: Warning and Caution are indicated in this guide and the product itself to help protect the users
from danger.
WARNING
■ Installation
Entrust installation of the
product to the service center
because improper installation
may cause fire, an electric
shock, explosion, and physical
injury.
Use the original parts in
order to prevent fire, an
electric shock, explosion,
and product breakdown.
Keep combustible and/or
inflammable materials away
from the product in order to
prevent fire or product
breakdown.
Service Center
¿ł
¿‰ˆ¿
¿‰ˆ`⁄`
¿ł
¿‰ˆ¿
¿‰ˆ`⁄`
Original Parts
Do not disassemble, repair, or
modify the product at your
discretion in order to prevent fire
or an electric shock.
¿ł
¿‰ˆ¿
Do not install the product in wet
and humid areas in order to
prevent product breakdown.
Do not expose the product to the
sun in order to prevent product
breakdown.
¿‰ˆ`⁄`
¿ł
¿‰ˆ¿
¿‰ˆ`⁄`
Owner’s Manual 3
ENGLISH
• For all the problems arising after installation by someone who has no relevant qualifications, LG will not provide
free service.
Safety Precautions
■ In-use
Do not modify or lengthen the
power cable at your discretion.
It may cause fire or an electric
shock.
Do not place a heating device
near the product. It may cause
fire.
Do not drop water on to the
product. It may cause an electric
shock or product breakdown.
¿ł
¿‰ˆ¿
Do not place something heavy on
the power cable. It may cause fire
or an electric shock.
¿‰ˆ`⁄`
Do not place a heavy thing on the
product. It may cause product
breakdown.
If the product was submerged
under water, ask the service
center for instruction. It may
cause fire or an electric shock
unless you do that.
ter
ice
v
Ser
¿ł
¿‰ˆ¿
Cen
¿‰ˆ`⁄`
CAUTION
Make sure children or senor
citizens use the product under
proper observation in order to
prevent safety accident.
¿ł
¿‰ˆ¿
Do not subject the product to
shock. It will cause product
breakdown.
Do not pick the product with a
sharp tool. It may cause
product breakdown with the
damage to its parts.
¿‰ˆ`⁄`
¿ł
¿ł
¿‰ˆ¿
¿‰ˆ¿
¿‰ˆ`⁄`
¿‰ˆ`⁄`
■ In-use
Do not clean the product with strong cleanser such
as solvent. Use soft clothes in order to prevent fire
or product deformation.
¿ł
¿‰ˆ¿
Do not touch the product with a wet hand. Do not
pull the lead cable. It may cause product breakdown
or an electric shock.
¿‰ˆ`⁄`
¿ł
4 Simple Central Controller
¿‰ˆ¿
¿‰ˆ`⁄`
Before Use
Before Use
System Drawing
ENGLISH
Total 128 indoor units can be controlled by central controllers using function controller along with.
Function controller is connected as shown below.
PI 485
Indoor unit
PQRCHCS0
Defrost Preheat Out door
Slo
Room Temp
Lo
Total on
Med
Central Run
Hi
Po
(1)
(3)
(16)
Cooling Heating Auto Dry Fan
MODE
Central
controller
FAN
SPEED
SEARCH
Individual controller
Function
controller
• Function controller and PI 485 are sold separately.
Owner’s Manual 5
Before Use
Name of Each Part
Central controller
1
3
2
4
5
1. On/Off status display LED (total 16EA)
Displays the status of the indoor unit if
individual On/Off button is pressed.
• Cooling/dehumidification/blowing
operation: Green
• Heating operation: Orange
• Failure of product: Red
• Stop: Off
2. Power display LED
• Application of power: Green
• No power: Off
• During control: Flickering
3. Individual On/Off button (total 16EA)
On/Off control of the connected indoor
units.
4. Total Off button
Sequentially turns off all indoor units
connected to it.
5. Total On button
Sequentially starts all indoor units
connected to it.
Annexed parts
Central controller anchoring
screws (4EA)
Owner/Installation manual
Actual name description
sheet
Addressing remote control
AAA cell (2EA)
Guide sheet
6 Simple Central Controller
Operation Tips
Operation Tips
Control of On/Off operation
ENGLISH
Individual Operation
1. Press the individual On/Off button, then the equivalent
unit starts and LED is on.
2. If pressing the individual On/Off button, equivalent unit
stops and LED is off.
Total Control for Each Group
• Press Total On button, then all units of that group
operate sequently and LED is on.
• Press Total Off button, then each group units stop
sequently and LED is off.
Total On/Off Operation (master & slave combination)
1. Press Total On button for more than 2sec, then all
linked units start sequentially and their LEDs turn
on.
2. Press Total Off button for more than 2sec, then all
linked units stop sequentially and their LEDs turn
off.
Owner’s Manual 7
Operation Tips
• Mode change function doesn't work when the function controller is connected with the system.
Mode Change
Operating mode change for individual
indoor unit
While changing the operating mode of the indoor unit, press the individual
Operate/Stop button for 2 seconds and the operating mode of the
applicable indoor unit will change from cooling to heating mode or from
heating to cooling mode.
When the indoor unit is running in the cooling mode, the status indicator
LED would be green and when the indoor unit is running in the heating
mode, it will be orange.
❈ This is applicable to heatpump models only.
Operating mode change for
group of indoor units
1. Cooling operation of group of indoor units
Press the Total On, Total Off and no. 5 button
simultaneously to change all indoor units to cooling
mode through the Central controller and the LEDs
will turn green.
2. Heating operation of group of indoor units
Press the Total On, Total Off and no. 8 button
simultaneously to change all indoor units to heating
mode through the Central controller and the LEDs
will turn orange.
8 Simple Central Controller
Operation Tips
• Control is available only by central controller & control by individual remote controller is impossible
Setting Individual Lock
ENGLISH
Setting individual lock
Press Total On and individual On/Off button at the same time.
• In this case, equivalent unit is controlled only by Central
controller.
After lock function is set, the equivalent LED of locked unit
blinks for 5 sec.
Cancellation
Press, Total Off and individual On/Off button at the same time
to cancel the lock function.
After lock function is canceled, the equivalent LED of unlocked
unit blinks for 5 sec.
Setting Total Lock for Each Group
Setting total lock
Press Total On, Total Off and no. 1 button at the same time.
• All linked units are now controlled only by central controller,
control of main body is impossible. After lock function is set,
LEDs of all locked units blink for 5 sec.
Cancellation
Press Total On, Total Off and no. 4 button at the same time.
• Lock of all units is cancelled and the LEDs of all unlocked
units blink for 5 sec.
Check of the locked units
Press Total On and Total Off
• LED of locked units blinks for 5 sec.
Owner’s Manual 9
Operation Tips
Connected Indoor Unit Search Function
Automatic search
When power is connected to the Central controller set as
master, LEDs from no. 1 to 16 will light up in sequence and
automatically runs a search for all the connected indoor units
for 3 minutes. This is generally the just operation after the
installation of the controller.
Indoor unit re-search
If all indoor units have not been searched during the automatic
search, press the Total On, Total Off and no. 16 button
simultaneously to re-search all the connected indoor units from
no. 1 to 16 by lighting up the LEDs in sequence.
Connected indoor unit indication
Press the Total On, Total Off and no. 13 button simultaneously
and all LEDs of the indoor units connected to a group/central
controller and the power LEDs will flash simultaneously to
notify which indoor units are connected to the central
controller.
10 Simple Central Controller
Operation Tips
Self Diagnosis for Indoor unit
Normal
ENGLISH
The On/Off status indicator LED of individual indoor unit is On/Off
(depends upon unit state)
Error condition
If there is an error in the indoor unit, the On/Off status indicator LED
of the that indoor unit turns red and when it recovers normal
condition, the LED will turn green or orange depending on the
operating mode.
Set Group Inquiry
Press the Total On, Total Off and no. 6 button simultaneously.
The On/Off status indicator LED equivalent to the group number set
in the controller will flash.
e.g. If LED 2 blinks, the group no. is 1.
Owner’s Manual 11
Operation Tips
Function Controller Connection
Individual indoor unit control
1. Press the individual On/Off button of the central controller and select the indoor unit to be controlled.
Now the applicable indoor unit will start or stop.
2. Function controller indicates the operating status of the selected indoor unit and makes it to change the
condition to adjust the wind/set temperature of the operating mode.
PQCSC101S0
Group indoor unit control(1 group)
1. Press Total On/Total Off button of the Central controller. Then all the connected units will operate/stop.
2. Function controller indicates the operating statue of the first indoor unit of that group if no settings have been
made at functional controller.
3. However all indoors can also work under same running conditions as a group by making settings at the
functional controller.
All Groups (master & slave) Indoor Unit Control
1. Press Total On/Total Off button for more than 3 seconds. Then all indoor units conected to whole network will
start/stop.
2. Function control displays the operating status of the first indoor unit of master controller only. It also display
"Total on" on its screen. Now the settings can be done for all groups using function controller.
PQCSC101S0
12 Simple Central Controller
Operation Tips
Group selection from Master Centrol Controller
2. Function controller of the selected slave controller displays the operating status of the first indoor unit. It also
displays "Total on" on its screen. Now the setting can be done for whole group/slave indoor units using function
controller.
Slave no. 3 group
Slave no. 2 group
PCS-B101S0
Function controller
Master no. 1 group
Indoor unit search
1. Select the search button of the function controller.
2. The On/Off status indicator LED of the applicable indoor unit of the central controller will flash for 5 seconds to
indicate that the function control is in progress.
Owner’s Manual 13
ENGLISH
1. Press the On/Off button for more than 3 seconds on the master Central controller equivalent to the group no. of
slave controller whose indoor units you want to turn On.
ex) Press the no. 2 button on master Central controller for more than 3 seconds. Now all the indoor units of
slave/group 1 will be turned on.
Memo
14 Simple Central Controller
Download PDF