advertisement
▼
Scroll to page 2
of 35
ENGLISH LG ITALIANO ESPAÑOL LG New Wide Wired Remote Controller Owner's & Installation Manual FRANÇAIS Models: PQRCVSL0 PQRCVSL0QW DEUTSCH P/No.: MFL62129202 PORTUGUÊS • Please read this owner's & installation manual completely before installing the product. • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Please retain this owner's & installation manual for future reference after reading it thoroughly. êìëëäàâ IMPORTANT New Wide Wired Remote Controller Ownerʼs & Installation Manual Safety Precaution .........................................................................................................................................3 Part Description............................................................................................................................................4 Installation instruction.................................................................................................................................5 Group control..............................................................................................................................................7 Installer Setting - How to enter installer setting mode ................................................................................8 Installer Setting - Test Run Mode.............................................................................................................11 Installer Setting - Setting Address of Central Control...............................................................................12 Installer Setting - E.S.P. ...........................................................................................................................13 Installer Setting - Thermistor ....................................................................................................................15 Installer Setting - Ceiling Height Selection ...............................................................................................16 Installer Setting - Static Pressure Setting.................................................................................................17 Installer Setting - Remote Controller Master/Slave Setup .......................................................................18 Installer Setting - Override Master/Slave Setting .....................................................................................19 Installer Setting - Dry Contact Mode Setting ............................................................................................20 Installer Setting - Zone State....................................................................................................................21 Installer Setting - Celsius / Fahrenheit Switching .....................................................................................22 Installer Setting - Zone Type Setting ........................................................................................................23 Installer Setting - Zone Number Setting ...................................................................................................24 Installer Setting - Option Function Setting................................................................................................25 Owner's instruction....................................................................................................................................26 Standard Operation - Standard Cooling ...................................................................................................26 Standard Operation - Power Cooling .......................................................................................................27 Standard Operation - Heating Mode ........................................................................................................27 Standard Operation - Dehumidification Mode ..........................................................................................28 Standard Operation - Fan Mode...............................................................................................................28 Standard Operation - Auto Operation Mode ............................................................................................29 Standard Operation - Temperature Setting/Room Temperature Check...................................................30 Standard Operation - Airflow Setting........................................................................................................31 Sub function - Direct Wind / Indirect Wind ..............................................................................................32 Sub function - Plasma Purification ...........................................................................................................34 Sub function - Humidifier ..........................................................................................................................35 Sub function - Electric Heater...................................................................................................................36 Sub function - Energy-Saving Cooling Operation.....................................................................................37 Sub function - Robot Cleaning Manual Setup ..........................................................................................38 Function setting - Child Lock ....................................................................................................................39 Function setting - Robot Cleaning Automatic Setup.................................................................................40 Function setting - Filter Sign Clear ...........................................................................................................41 Function setting - Elevation Grill...............................................................................................................42 Function setting - Vane Angle Control......................................................................................................43 Function Setting - Change Temp .............................................................................................................44 Function setting - Zone Control ................................................................................................................45 Function setting - Changing Current Time ..............................................................................................46 Function setting - Auto Cleaning .............................................................................................................48 Programming - Simple Reservation .........................................................................................................49 Programming - Sleep Reservation ...........................................................................................................50 Programming - ON Reservation ...............................................................................................................51 Programming - OFF Reservation .............................................................................................................53 Programming - Weekly Reservation.........................................................................................................55 Programming - Holiday Reservation ........................................................................................................57 Ventilation Product User Manual - Interlinked Air conditioner and Ventilation .........................................58 Ventilation Product User Manual - Interlinked operation with general ventilation ...................................59 Manual Conversion - Pressing ʻVentilationʼ button in ventilation mode will manually convert..................60 Ventilation Product User Manual - Interlinked Operation with Direct Expansion Ventilation....................61 Ventilation Product User Manual - Single Operation with Direct Expansion Ventilation ..........................62 Ventilation Product Additional Operations - Fast / Power Saving ............................................................63 Ventilation Product Function Settings ......................................................................................................64 Ventilation Product Reservations Settings ...............................................................................................65 Ventilation Product Installer Setting Functions - Entering Method ...........................................................66 Different mode drive ................................................................................................................................67 Checkups before reporting breakdown ....................................................................................................68 2 New Wide Wired Remote Controller Safety Precaution • The installation requires expert skills, and it should be installed by the service center or other shops specialized in the installation and recognized by our company. • For all the problems arising after installation by someone who has no relevant qualifications, our company will not provide free service. • The following safety cautions are provided to prevent unexpected dangers or losses. WARNING : If the user does not follow the mandatory items, it may result in serious injury or death. CAUTION : If the user does not follow the mandatory items, it may cause personal injury or property damage. : Warning and Caution are to call the userʼs attention to the possible danger. Read and follow them carefully in order to prevent a safety accident. : Warning and Caution are indicated in this guide and the product itself to help protect the users from danger. WARNING n Installation Be sure to request to the service center or installation specialty store when installing products. • It will cause fire or electric shock or explosion or injury. Request to the service center or installation specialty store when reinstalling the installed product. • It will cause fire or electric shock or explosion or injury. Do not disassemble, fix, and modify products randomly. • It will cause fire or electric shock. n In-use Do not place flammable stuffs close to the product. • It will cause fire. Do not allow water to run into the product. • It will cause electric shock or breakdown. Request to the service center or installation specialty store when the product becomes wet. • It will cause fire or electric shock. Do not give the shock to the product. • It will cause breakdown when giving the shock to the product. Do not give the shock using sharp and pointed objects. • It will cause breakdown by damaging parts. CAUTION n In-use Do not clean using the powerful detergent like solvent but use soft cloths. • It will cause fire or product deformation. Do not press the screen using powerful pressure or select two buttons. Do not touch or pull the lead wire with wet hands. • It will cause product breakdown or malfunction. • It will cause product breakdown or electric shock. Ownerʼs & Installation Manual 3 ENGLISH TABLE OF CONTENTS Safety Precaution Part Description Installation instruction Name and Function of Remote Controller 1 10 9 8 2 3 7 4 11 12 13 5 6 14 15 Please attach the inform label inside of the door. Please choose proper language depend on your country. 1. Please fix tightly using provided screw after placing remote controller setup board on the place where you like to setup. 1 OPERATION INDICATION SCREEN 2 SET TEMPERATURE BUTTON 3 FAN SPEED BUTTON 4 ON/OFF BUTTON 5 OPRATION MODE SELECTION BUTTON 6 WIRELESS REMOTE CONTROLLER RECEIVER • Some products don't receive the wireless signals. 7 AIR FLOW BUTTON 8 SUBFUNCTION BUTTON 9 FUNCTION SETTING BUTTON 10 VENTILATION BUTTON 11 RESERVATION 12 UP,DOWN,LEFT,RIGHT BUTTON • To check the indoor temperature, press button. 13 ROOM TEMPERATURE BUTTON 14 SETTING/CANCEL BUTTON 15 EXIT BUTTON j Some functions may not be operated and displayed depending on the product type. - Please set it up not to bend because poor setup could take place if setup board bends. Please set up remote controller board fit to the reclamation box if there is a reclamation box. - Install the product so as not to make a gap with the wall side and to prevent shaking after the installation. 2. Can set up Wired remote controller cable into three directions. - Setup direction: the surface of wall reclamation, upper, right - If setting up remote controller cable into upper and right side, please set up after removing remote controller cable guide groove. h Remove guide groove with long nose. ① Reclamation to the surface of the wall ② Upper part guide groove ③ Right part guide groove 2 2 Accessory 3 Connection Cable (1EA, 10m) Screw (4 EA) Owner's / Installation manual Inform label (8EA-8Languages) 3 1 <Wire guide grooves> 4 New Wide Wired Remote Controller Ownerʼs & Installation Manual 5 ENGLISH Installation instruction Part Description Installation instruction Installation instruction - Please connect not to make a gap at the remote controller and setup board’s upper and lower, right and left part. <Connecting order> Wall Side Wall Side - Before assembly with the installation board, arrange the Cable not to interfere with circuit parts. When separating remote controller from setup board, as the picture below, after inserting into the lower separating hole using screw driver and then, spinning clockwise, remote controller is separated. <Separating order> Wall Side Wall Side - There are two separating holes. Please individually separate one at a time. - Please be careful not to damage the inside components when separating. 12V Red Yellow GND Black Group control 1. When installing more than 2 units of air conditioner to one wired remote controller, please connect as the right figure. • If it is not event communication indoor unit, set the unit as slave. • Check for event communication through the product manual. GND Signal wire 12V GND 1 2 3 4 5 6 7 8 ON 1 2 3 4 5 6 7 8 #3 switch OFF: Master (Factory default setting) Please check if connector is normally connected. Indoor Unit side Connecting cable Signal wire When controlling multiple indoor units with event communication function with one remote controller, you must change the master/slave setting from the indoor unit. - Indoor units, the master/slave configuration of the product after completion of indoor unit power ‘OFF’ and then ‘ON’ the power after 1 minutes elapsed sign up. - For ceiling type cassette and duct product group, change the switch setting of the indoor PCB. ON 4. Please connect indoor unit and remote controller using connection cable. Signal ENGLISH 3. Please fix remote controller upper part into the setup board attached to the surface of the wall, as the picture below, and then, connect with setup board by pressing lower part. #3 switch ON: Slave - For wall-mount type and stand type product, change the master/slave setting with the wireless remote controller. (Refer to wireless remote controller manual for detail) ❈ When installing 2 remote controllers to one indoor unit with event communication function, set the master/slave of the remote controller. (Refer to remote controller master/slave selection) When controlling the group, some functions excluding basic operation setting, fan level Min/Mid/Max, remote controller lock setting and time setting may be limited. CAUTION • Installation work must be performed in accordance with the national wiring standards by authorized personnel only. • Installations must comply with the applicable local/national or international standards. • Apply totally enclosed noncombustible conduit (metal raceway) in case of local electric & building code require plenum cable usage. 5. Please use extension cable if the distance between wired remote controller and indoor unit is more than 10m. CAUTION When installing the wired remote controller, do not bury it in the wall. (It can cause damage in the temperature sensor.) Do not install the cable to be 50m or above. (It can cause communication error.) • When installing the extension cable, check the connecting direction of the connector of the remote controller side and the product side for correct installation. • If you install the extension cable in the opposite direction, the connector will not be connected. • Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above. 6 New Wide Wired Remote Controller 2. When installing more than 2 wired remote controllers to one air conditioner, please connect as the right picture. • When installing more than 2 units of wired remote controller to one air conditioner, set one wired remote controller as master and the others all as slaves, as shown in the right picture. • You cannot control the group as shown in the right for some products. • Refer to the product manual for more detail. GND Signal wire 12V GND Signal wire 12V B Y R MASTER B Y R SLAVE <When simultaneously connecting 2 sets of wired remote controller> • When controlling in groups, set the master/slaver of the remote controller. Refer to Installer setting section on how to set master/slave for more detail. Owner’s & Installation Manual 7 Installation instruction Installation instruction CAUTION Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it can cause problems to the product, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided. pressing button long for 3 seconds, 1 Ifit enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. No. 1 2 Function Test Run Address Setting Code 01 02 3 E.S.P. Value 03 4 Thermistor 04 5 Ceiling Height 05 6 Static Pressure 06 7 Master Setting 07 8 Override Setting 08 9 Dry Contact 09 10 Release 3 Min. Delay 10 11 Zone State 11 12 Celsius Fahrenheit Switching 12 you enter the setting mode 2 When initially, Function code is displayed on the bottom of the LCD screen. Function Code Value • Some categories of the menu may not be displayed according to the function of the product, or the menu name may be different. 13 Zone Type 13 14 15 16 17 18 19 20 Zone Number Plasma Electric heater Humidifier Elevation Grill Ventilation Kit Auxiliary Heater 14 20 21 22 23 24 25 Value 01:Set 00~FF : Address <ESP Step> <ESP Value> <Example> 01:VeryLow 0 ~ 255 02:Low 03:Med Function Code ESP step ESP value 04:High 05:Very High 01:Remo 02:Indoor 03:2TH 01:Low 02:Med 03:High 04:Very High 01:V-H 02:F-H 03:V-L 04:F-L ※ If only “Plus1” series models 00 : Group setting 00:Slave 01:Master 01 : Single setting 00:Slave 01:Master 00:Auto-Off 01:Auto-On 01:Set 01:Variable 02:Fixed 00:Celsius (Optimized only for U.S.A) 01:Fahrenheit 00:Zone Controller 01:Damper Controller 02~04(Zone number) 00: Not Installed 01: Installed j Some contents may not be displayed depending on the product function 8 New Wide Wired Remote Controller Ownerʼs & Installation Manual 9 ENGLISH Installer Setting -How to enter installer setting mode <Installer Setting Code Table> 1) General air-conditioner product Installation instruction Installation instruction No. 1 Function Test Run Code 01 01 : Test Run Setup Address Setting 02 00~FF : Address of Central Control 3 SA(Supply Air) ESP 03 4 EA(Exhaust Air) ESP 04 <ESP level> 01 : Low 02 : High 03 : Super High 01 : Normal 02 : Opposite 01 : Supply Air First 02 : Exhaust Air First 00 : Slave 01 : Master 00 : Slave 01 : Master 00 : Auto-Off 01 : Auto-On 01 : Set 01 : Variable 02 : Fixed 00 : Not in Use 01 : Use 00 : Automatic 01 : Manual 5 Product Direction 05 6 Quick Refresh Priority 06 7 Master Setting 07 8 Override Setting 08 9 Dry Contact 09 10 Release Of 3 Minute Delay 10 11 Zone State 11 13 Humidification for Singular Ventilation Humidification for Heat Mode Ventilation 13 14 After installing the product, you must run a Test Run mode. For details related to this operation, refer to the product manual. Value 2 12 ENGLISH Installer Setting -Test Run Mode 2) General Ventilation product <ESP value> 0~255 <Example> Function Code ESP step pressing button long for 3 seconds, 1 Ifit enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. - Please cancel the right and left of wind direction for RAC product. ESP value Function Code 2 Set Setup figure '01' blinks at the lower part of indication window. j Some contents may not be displayed depending on the product function 3 Press button to start. the test run, pressing the below 4 During button will exit the test run. - Select operation, temperature up/down, wind flow control, wind direction, start/stop button. 10 New Wide Wired Remote Controller Ownerʼs & Installation Manual 11 Installation instruction Installation instruction Installer Setting -E.S.P. This is the function that decides the strength of the wind for each wind level and because this function is to make the installation easier. pressing button long for 3 1 Ifseconds, it enters into remote • If you set ESP incorrectly, the air conditioner may malfunction. • This setting must be carried out by a certificated-technician. controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. into address setup mode by using 2 If entering button, it indicates as picture below. into ESP setup mode by using 2 If entering button, it indicates as the picture Indoor No. Group No below. Function Code Group No. by pressing 3 Set button.(0~F) ESP step Function Code Function code, ESP code to Indoor No. setting option 4 Move by pressing button. ESP value 3 ESP value Select ESP fan step by pressing button. (01: very low, 02: low, 03: medium, 04: high, 05: very high) to ESP value setting by pressing 4 Movebutton. Indoor No. by pressing 5 Set button. (It is 000 when delivering from the warehouse.) 5 Press 6 Press button to save. button to setup ESP value. (It is possible to setup ESP value from 1 to 255, and 1 is the smallest and 255 is the biggest.) button will exit settings mode. 7 Pressing ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. 12 New Wide Wired Remote Controller • When setting ESP value on the product without very weak wind or power wind function, it may not work. Ownerʼs & Installation Manual 13 ENGLISH Installer Setting - Setting Address of Central Control It's the function to use for connecting central control. Please refer to central controller manual for the details Installation instruction Installation instruction Installer Setting -Thermistor This is the function to select the temperature sensor to judge the room temperature. and 5, that corresponds each wind flow 7 Press pressing button long for 3 1 Ifseconds, it enters into remote button to save. controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. 2 button to exit. 8 Press ❈ After setup, it automatically gets out of Function code, ESP code setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. If moving to room temperature perception sensor selection menu by pressing button, it indicates as picture below. ESP value Thermistor value by pressing 3 Set button. (01: Remote Controller, • Please be careful not to change the ESP value for each fan step. • It does not work to setup ESP value for very low/power step for some products. • ESP value is available for specific range belongs to the product. 02: Indoor, 03: 2TH) Function Code Thermistor setting Press button to save. 4 button will exit settings mode. 5 Pressing ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. <Thermistor Table> Temperature sensor selection 01 Remote controller 02 Indoor unit Cooling 03 2TH Heating Function Operation in remote controller temperature sensor Operation in indoor unit temperature sensor Operation of higher temperature by comparing indoor unit's and wired remote controllerʼs temperature. (There are products that operate at a lower temperature.) Operation of lower temperature by comparing indoor unit's and wired remote controller's temperature. j The function of 2TH has different operation characteristics according to the product. 14 New Wide Wired Remote Controller Ownerʼs & Installation Manual 15 ENGLISH ESP fan step again by using 6 Select button and setup ESP value, as No. 4 Installation instruction Installation instruction Installer Setting -Static Pressure Setting This function is applied to only duct type. Setting this in other cases will cause malfunction. pressing button long for 3 1 Ifseconds, it enters into remote button for 4 seconds 1 Press to enter the installer setting controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. 2 If moving to ceiling height selection menu by pressing button, it indicates as picture below. 3 Select ceiling height value by pressing button. (01:Low, 02:Medium, 03:High, 04:Very high) mode until timer segment displays “01:01”. 2 If pressing button repeatedly, it moves to static pressure selection menu as picture below. pressure by pressing 3 Select static button. (01:V-H, 02:F-H, 03:V-L, 04:F-L) Function Code Function Code 4 Press button to save. 4 Press button will exit settings mode. 5 Pressing ❈ After setup, it automatically gets out of 5 setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. <Ceiling Height Selection Table> 01 02 03 04 Ceiling Height Level Low Medium High Very high Pressure Thermistor setting button to save. Pressing button will exit settings mode. ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. <Static Pressure Setting Table> Description Decrease the indoor airflow rate 1 step from standard level Set the indoor airflow rate as standard level Increase indoor airflow rate 1 step from standard level Increase indoor airflow rate 2 steps from standard level • Ceiling height setting is available only for some products. • Ceiling height of ʻVery highʼ function may not exist depending on the indoor unit. • Refer to the product manual for more details. 16 New Wide Wired Remote Controller Pressure selection 01 02 03 04 V-H F-H V-L F-L Function Zone state Variable Fixed Variable Fixed ESP standard value High High Low Low Ownerʼs & Installation Manual 17 ENGLISH Installer Setting -Ceiling Height Selection This function is to adjust FAN Airflow rate according to ceiling height (For ceiling type product) Installation instruction Installation instruction Installer Setting - Override Master/Slave Setting Override master/slave selection function is, since Multi-V 7 series model, the function to prevent product's different mode operation. If it setup as the slave, It blocks to change opposite run mode to outdoor unit cycle (cooling/heating) pressing button long for 3 1 Ifseconds, it enters into remote pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. 2 controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. If pressing button repeatedly, it moves to master/slave selection menu as picture below. 2 Master/ Slave by pressing 3 Select button. If pressing button repeatedly, it moves to override master/slave selection menu as picture below. Master/ Slave by pressing 3 Select button. (00: Slave, 01: Master) (00: Slave, 01 : Master) Function Code Master/Slave value Press button to save. Function Code 4 4 Press Master/Slave button to save. button will exit settings mode. 5 Pressing ❈ After setup, it automatically gets out of button will exit settings mode. 5 Pressing ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. Remote controller Master Slave Function Indoor unit operates based on master remote controller at group control. (Master is set when delivering from the warehouse.) Setup all remote controllers except one master remote controller to slave at group control h Refer to the 'group control' part for details setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. h Override master/slave selection function is possible to use only when it is connected to the succeeding models of Multi-V 7 series. • If it is set as Override Slave, icon is displayed on LCD Display Window. (See Figure 1) • When controlling in groups, basic operation settings, airflow strength weak/medium/strong, lock setting of the remote controller, time settings, and other functions may be restricted. 18 New Wide Wired Remote Controller Figure 1. Ownerʼs & Installation Manual 19 ENGLISH Installer Setting-Remote Controller Master/Slave Setup It is a function for settings in group control, or 2-remote controller control. Installation instruction Installation instruction pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. pressing button repeatedly, it moves to 2 Ifremote controller dry contact mode setup menu as picture below. Dry contact setting by 3 Select pressing button. (00 : Manual, 01 : Automatic) Installer Setting - Zone State It is the function to setup indoor unit's wind flow to variable or fixed. - Variable : Comp ON, setup airflow. Comp OFF, weak wind - Fixed : Comp ON, setup airflow. Comp OFF, setup airflow pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. moving to ceiling height selection menu by 2 Ifpressing button, it indicates as picture below. Zone State rate fixing mode by 3 Select pressing button. (01: Variable, 02: Fixed) Function Code 4 Press Dry Contact setting value Function Code Zone State fixing mode button to save. 4 Press button will exit settings mode. 5 Pressing ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. button to save. button will exit settings mode. 5 Pressing ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. ▶ What is Dry Contact? Like hotel card key and body perception sensor, it is the signal of the point of contact when using air-conditioner by interlocking. • Please refer to dry contact manual for more details. 20 New Wide Wired Remote Controller Ownerʼs & Installation Manual 21 ENGLISH Installer Setting-Dry Contact Mode Setting Dry contact function is the function that is possible to use only when dry contact equipment is separately purchased/setup. Installation instruction Installation instruction pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. 2 Repeat pressing Function code 12. button to select Function Code conversion mode value Ex) Fahrengeit Setting Installer Setting-Zone Type Setting This function is only available on some products. It is possible to setup zone new type or old one of the product which is available to install the damper controller. CAUTION If you set zone number incorrectly, the product may malfunction especially in zone control. This function must carried out by a certificated-technician. pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. pressing 2 Repeat Function code 13. button to select Temperature unit mode by 3 Select pressing button. Function Code (00: Celsius, 01: Fahrenheit) Zone type value Ex) Setting the Zone Type as "New" Zone Type by pressing 3 Select button 4 Press button to save or release. (00:Old, 01:New) 4 Press button to save or release. button to exit or 5 Press system will automatically exit after 25 seconds without any input. h Whenever press button to exit or 5 Press system will automatically exit after 25 seconds without any input. button in Fahrenheit mode, the temperature will increase/drop 2 degrees. 22 New Wide Wired Remote Controller Ownerʼs & Installation Manual 23 ENGLISH Installer Setting-Celsius / Fahrenheit Switching This function is used for switching the display between Celsius and Fahrenheit. (Optimized only for U.S.A) Installation instruction Installation instruction Installer Setting - Option Function Setting pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. pressing 2 Repeat Function code 14. Function Code button to select Setting feature for indoor unit when air cleaning / heater / humidifier / Up/down grill / Ventilation KIT /Auxiliary Heater is newly installed, or installed unit is removed. pressing button long for 3 1 Ifseconds, it enters into remote controller setter setup mode. - If pressing once shortly, it enters into user setup mode. Please press more than 3 seconds for sure. button repeatedly, it moves to 2 Ifthepressing selected option function code as picture below. Function Plasma purification Electric heater Humidifier Elevation grill Ventilation kit Auxiliary heater Zone Number installed Ex) Setting the Zone Number for "2" Zone Number by pressing 3 Select button Code 20 21 22 23 24 25 existing condition 3 Select of each mode by pressing button. (02~04 : number of zone installed) (00: not installed, 01 : installed) Function Code 4 Press button to save or release. 4 Press Existing condition button to save. button will exit settings mode. 5 Pressing ❈ After setup, it automatically gets out of button to exit or 5 Press system will automatically exit after 25 seconds without any input. 24 New Wide Wired Remote Controller setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. Ownerʼs & Installation Manual 25 ENGLISH Installer Setting-Zone Number Setting This function is only available on some products. Zone Number is to set the number of installed zones. It's possible to control only in zone new type Owner's instruction Owner's instruction It makes the room cool using pleasant and fresh air quickly Standard Operation - Standard Cooling 1 Press indoor. It cools the room by comfortable and clean wind. 1 Press indoor. button to trun on the button to turn on the button to select 2 Press cooling operation mode. button to select 2 Press Cooling operation mode. button continuously 3 Press until 'Po' displayed. the desired temperature 3 Adjust by pressing buttons. Press button to check the Room temperature. When setting the desired temperature higher than room temperature, only ventilation wind is blow out instead of cooling wind. What is Power Cooling? • Desired temperature: Po (actually 18°C) • Wind flow: power wind • Wind direction: fix to air-cooling position } It make room temperature drop fast by running h Partial product has no power air-cooling function. Standard Operation - Heating Mode It supplies warm wind to the indoor h Setting Temp Range : 18˚C~30˚C (64˚F~86˚F) 1 Press indoor. button to turn on the button to select 2 Press Heating mode. (To check the indoor temperature, press the room temperature button.) the desired temperature 3 Adjust by pressing buttons. When setting the desired temperature lower than room temperature, there is only ventilation wind. • Heating drive only operates at the cooling and heating model. • Heating doesn't operate at cooling exclusive model. 26 New Wide Wired Remote Controller Ownerʼs & Installation Manual 27 ENGLISH Standard Operation - Power Cooling Owner's instruction Owner's instruction Owner's instruction ENGLISH Standard Operation - Dehumidification Mode Standard Operation - Auto Operation Mode It removes humidity while air-cooling weakly. 1 Press indoor. button to turn on the button to select 2 Press Dehumidification mode. 1 Press indoor. button to turn on the button to select 2 Press Artificial intelligence Mode. The temperature setting can not be adjusted during operation this mode. the button to select 3 Press airflow rate feeble → weak → medium → strong → automatic. (The initial wind powerfulness of humidity removal drive is 'weak'.) • In rainy season or high humidity climate, it is possible to operate simultaneously dehumidifier and cooling mode to remove humidity effectively. • The menu item of wind powerfulness might not be partially selected according to the product. Standard Operation - Fan Mode It blows the air as it is in the indoor, not the cold wind. 1 Press indoor. 2 Press Mode. can adjust 3 You the temperature as the picture on the right for cooling and heating model. the case of 4 For cooling exclusive, as the picture on the right, you can adjust the temperature from hot to cold, from "-2" to "2" based on "00". When cold When cool When appropriate When warm When hot button to turn on the button to select Fan During operating Auto Operation mode: • We can use the FAN SPEED button • We can change manually to other operation mode. time pressing button, you 3 Every can select wind flow in order of Very Low → Low → Medium → High → Very High. When running ventilation, compressor of AHU doesn't work. • Ventilation drive does not release cool wind but general fan • Because it releases the wind that has no temperature difference from the room, it functions to circulate the inside air. • The menu item of wind powerfulness might not be partially selected according to the product. 28 New Wide Wired Remote Controller Ownerʼs & Installation Manual 29 Owner's instruction Owner's instruction Temperature Setting can simply adjust the desired 1 We temperature. • Press the buttons to adjust the desired temperature. : Increase Temp. per one time pressing : Decrease Temp. per one time pressing • Room temp: Indicate the current room temperature. • Set temp: Indicate the temperature that user want to set. Cooling operation: - The cooling mode doesn't work if desired temperature is higher than room temperature Please lower the desired temperature. Heating operation: - The heating mode doesn't work if desired temperature is lower than room temperature Please increase the desired temperature. Standard Operation - Airflow Setting Wind powerfulness : You can simply adjust desired wind powerfulness. setup desired wind 1 Please powerfulness by wind powerfulness button. • Every time you press wind powerfulness, you can select the wind flow in order of ‘feeble → weak → weak medium → medium → medium strong → strong → power → automatic’. • The menu item might not be partially selected according to product function. • Please refer to product manual for product’s detailed function. Wind direction : You can simply adjust desired wind direction. set desired wind direction 1 Please by pressing button. You can select wind direction of (comfortable wind → Up/Down and Right/Left → Right/Left → Up/Down) by pressing button. Partial item of wind directions might not be selected according to product function. Please refer to product manual for product’s detailed function. Room Temperature Check press button, the room 1 Whenever temperature will be displayed within 5 seconds. After 5 seconds, it turns to display the desired temperature. Because of location of remote controller, the real room temperature and the this displayed value can be different • For air-cooling drive, from 18°C to 30°C, and for heating drive, from 16°C to 30°C, you can select desired temperature. • 5°C is proper for the difference between room and outside temperature. 30 New Wide Wired Remote Controller Ownerʼs & Installation Manual 31 ENGLISH Standard Operation - Temperature Setting/Room Temperature Check Owner's instruction Owner's instruction The method to setup direct/indirect wind 1 Please press button. 2 The icon of direct/indirect wind blinks on the display, and then, if pressing button, direct/indirect wind icon is fixed and the function is setup. direct wind The method to cancel direct/indirect wind 1 Please press button. icon of direct/indirect wind 2 The blinks on the display, and then, if pressing button, direct/indirect wind icon is removed and the function is cancelled. pressing 3 Ifsetup mode. button, it gets out of ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. indirect wind 3 If pressing setup mode. button, it gets out of direct wind indirect wind • Direct/indirect wind function is additional function and it might not be indicated or operated at the partial product. • Direct/indirect wind function is possible only when product is running. 32 New Wide Wired Remote Controller Ownerʼs & Installation Manual 33 ENGLISH Sub function - Direct Wind / Indirect Wind It is the function to directly or indirectly control wind direction by body perception sensor. Owner's instruction Owner's instruction Sub function - Humidifier Only products with humidifying function can use this. The method to setup cleaning air 1 Repeat pressing until icon flash. 2 Operate or cancel Plasma Purification function by pressing button. ( icon appears/disappears on display part up to selection ) setting, press 3 After to exit. ENGLISH Sub function - Plasma Purification Only products with humidifying function can use this. button button ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. pressing 1 Repeatedly until icon flash. button on/off HUMIDIFIER by 2 Turn pressing button (The icon will be displayed in case of SETTING option and disappear in reverse case .) button to exit. 3 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Humidification function might not be operated at the partial product. • Cleaning air function is additional function and it might not be indicated or operated at the partial product. • Cleaning air function is possible only when product is running. • If you want independent cleaning air drive, please setup cleaning air by pressing additional drive button at ventilation drive. 34 New Wide Wired Remote Controller Ownerʼs & Installation Manual 35 Owner's instruction Owner's instruction Sub function - Energy-Saving Cooling Operation Power saving air-cooling function is the function to improve use's comfortableness and power saving capacity by adjusting desired temperature while running air-cooling It can only be set during heating operation. 1 Repeatedly pressing until icon flash. button 2 Turn on/off ELECTRIC HEATER by pressing button (the icon will be displayed in case of SETTING option and disappear in reverse case .) button to exit. 3 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Heater function is additional function and it might not be operated at the partial product. • The indoor unit product with Auxiliary Heater function set automatically displays (0) icon during the heating operation. 36 New Wide Wired Remote Controller pressing 1 Repeatedly until icon flash. button or cancel Energy-Saving 2 Operate function by pressing button. (To cancel power saving function, you move to power saving menu by pressing button, and then if pressing button, power saving icon disappears and the function is cancelled. ) button to exit. 3 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Power saving function is possible to setup only when running air-cooling. • Power saving function might not be operated at the partial product. Ownerʼs & Installation Manual 37 ENGLISH Sub function - Electric Heater It is a function to strengthen the heating ability by turning on the electric heater during the heating operation. Owner's instruction Owner's instruction pressing 1 Repeatedly until icon flash. button on/off Smart Clean function 2 Turn by pressing button. ❈ When the cleaning is finished, the smart cleaning display disappears automatically. ❈ To cancel robot cleaning manual setup function, you move to power saving menu by pressing button, and then if pressing button, "robot cleaning" icon disappears and the function is cancelled. setting, press 3 After to exit. button ❈ Robot cleaning manual setup function might not be operated at the partial product. ❈ When exiting without pressing set button, the manipulated value is not reflected. 38 New Wide Wired Remote Controller Function setting - Child Lock It is the function to use preventing children or others from careless using. button repeatedly until 1 Press the is flashing. moving to 'setup' icon area by 2 Ifusing button, 'setup' icon blinks, and child lock function is setup if pressing button at that time. cancelling lock function, if moving 3 When to 'cancel' icon by pressing button and then, pressing button, child lock function is cancelled. button to exit. 4 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. Ownerʼs & Installation Manual 39 ENGLISH Sub function - Robot Cleaning Manual Setup Robot cleaning function is the function for cleaner attached to the product to automatically clean the filter when using air-conditioner for the specific period of time. Owner's instruction Owner's instruction 1 Press the Function setting - Filter Sign Clear This function is to clear the indicator of indoor filter cleaning. 1 Press until the button repeatedly is flashing. button repeatedly until is flashing. the is flashing, press 2 When the to clear this display the flashing, press 2 Whenbutton to set/clear this function. Set state : Enable Auto Smart Clean function • When filter is covered by dust, it will reduce cooling/heating efficiency and accumulate more electric power. Therefore. do clean the filter whenever cleaning time is expired. Clear state : Disable Auto Smart Clean function h Filter cleaning indication is automatically cancelled without the separate cancellation after certain period of time. returning to manual robot cleaning, 3 When manual function is cancelled if moving to 'manual' icon by pressing Right/Left button and then, pressing button. button to exit. 4 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Robot cleaning function is an additional function of the product and might not be operated at the partial product. 40 New Wide Wired Remote Controller Ownerʼs & Installation Manual 41 ENGLISH Function setting - Robot Cleaning Automatic Setup Robot cleaning function is the function of cleaner attached to the product to automatically clean filter when using air-conditioner for the specific period of time. Set manual or automatic mode of smart cleaning. Owner's instruction Owner's instruction Function setting - Vane Angle Control This function is to adjust angle at which airflow is blow out. button 1 Press Repeat pressing pressing 1 Repeat icon flash. button until button until icon flash. to descent using button 2 Move and press button will display descent icon and the up/down grill will descent. up/down grill descents to the 3 When desired position, move to stop icon suing button and press to stop up/down grill. button filter cleaning is finished, fix the 4 When filter to the up/down grill, move to ascent icon using button, and press button to ascent up/down grill. button to exit. 5 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. button to select active vane : 2 Press 1 / 2 / 3 / 4 / All / Standard Select Vane number using buttons. ❈ Vane number : No. 1, 2., 3, 4, all, or standard - Selected vane is in operation. - Please verify the operating vane. - To set the angle of all the vanes, select 'all'. - To set as the factory default settings, select 'standard'. wind angle using 3 Select press button. the wind angles for the remaining 4 Set vanes as the same as above. ❈ There are products with vanes with no. 1 and no. 2 only according to the product types. Press • Elevation grill function only operates in the indoor unit with the elevation grill. button, and - The boundary of wind angle settings can be changed to 5 levels or 6 levels according to the product. - When selecting 'standard' for Vane number, the wind angle does not move. button to exit. setup, it automatically 5 ❈ After gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. button to complete and 6 Press active the setting process. (Airflow direction function will be released whenever setting vane angle) button to exit or 7 Press system will automatically release without any input after 25 seconds. 42 New Wide Wired Remote Controller Ownerʼs & Installation Manual 43 ENGLISH Function setting - Elevation Grill This function is to move the indoor filter up/down for cleaning filter. Owner's instruction Owner's instruction 1 Repeat pressing icon flash. ENGLISH Function Setting - Change Temp Function setting : Zone Control Change temperature is the function to setup air-cooling and heating drive automatically changeable according to the temperature at artificial intelligence drive mode. button until To turn on/off the zones by used of it 1 Repeaticonpressing flash. button until Ex) Turn on the zone 1 and zone 3. button to change. 2 Press ❈ Converting temp value : 1~7 button to complete 3 Press and active the setting process. button to select the zone 2 Press that which one you want to turn on/off. 3 Press button to turn on/off zone. button to exit or 4 Press system will automatically release without any input after 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. button To select other 4 Press zones If you want. Then, Press button to turn on/off that zone as mentioned above button to exit or 5 Press system will automatically release without any input after 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. 44 New Wide Wired Remote Controller Ownerʼs & Installation Manual 45 Owner's instruction Owner's instruction press function setup 1 Please button. If pressing function setup button repeatedly, it moves to time setup menu. ‘Time setup’ icon is indicated at that time and date blinks at current time indication area. button to move to 'Minute' 7 Press setting mode. (the 'Minute' segment will flash) Ex) Changing Current Time as 'Monday / AM 10:20'. Minute value by pressing 8 Setting button. 2 Press day. key to adjust the current 9 Press 3 button to finish. Press key to move to AM/ PM setting mode (the 'AM/ PM segment will flash). 10 AM/ PM value by 4 Setting pressing button. button to move to 'Hour' 5 Press setting mode. (the 'Hour' segment will In the process, press button to release and exit from setting mode. (In case of exit with incomplete information, it will return to the previous setting) ❈ When exiting without pressing set button, the manipulated value is not reflected. flash) Hour value by pressing 6 Setting button. 46 New Wide Wired Remote Controller Ownerʼs & Installation Manual 47 ENGLISH Function setting - Changing Current Time Owner's instruction Owner's instruction Programming - Simple Reservation You can set the reservation conveniently in the units of 1 hour from 1 hour to 7 hours. The method to setup Automatic Drying 1 Please press button to enter the 1 Press Programming mode. (the button. segment flashing) Ex) Setting Simple Reservation time as '3'. to automatic drying menu by 2 Move pressing button twice. 'Automatic Drying' icon will be displayed and the current status, 'DISABLE' will blink. 2 Press time. 3 Press button to adjust reservation button to finish setting. to ‘ABLE’ icon area by using 3 If moving button, ‘ABLE’ icon blinks, and automatic dry function is setup if pressing button at that time. button to exit. 4 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. returning to automatic dry no use, 4 When automatic dry function is cancelled if moving to ‘DISABLE’ icon by pressing and then, pressing button. pressing 5 Ifmode. h When simple reservation setup, product automatically runs or stops after the time that is set. button button, it gets out of setup ❈ After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. • Automatic dry function might not be operated at the partial product. 48 New Wide Wired Remote Controller Ownerʼs & Installation Manual 49 ENGLISH Function setting - Auto Cleaning Owner's instruction Owner's instruction Programming - ON Reservation button to enter the 1 Press Programming mode. Ex) Setting Sleep Reservation time as '3'. 2 Repeat pressing button to enter the SLEEP reservation setting mode. ( segment flashing) 3 Press time. button to adjust reservation Automatically turned On at reserved time that you set. 1 Press button. Ex) Setting ON Reservation Time as 'AM 10:20'. pressing button to 2 Repeat enter the ON reservation setting mode. ( segment flashing) 3 Press setting. button to adjust AM/ PM The SLEEP reservation time is from 1 to 7 hours. 4 Press button to finish setting. Whenever reservation is done. button to Hour setting 4 Press mode. When the Hour icon flash, please setting time. The setting range is within 1~12. button to exit. 5 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 60 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. - If reservation is setup, 'sleep' indication shows up at the lower part of LCD screen. button to shift to Minute 5 Press setting mode. When the Minute icon flash, please setting minute the setting range is within 00~59. finishing sleep reservation setup, 6 Ifair-conditioner product operates sleep drive and stops after the time that is set. CAUTION Please reserve proper time at sleeping. (Too much air-cooling is not good for your health.) • Because it automatically adjusts desired temperature for comfortable air-cooling at sleep drive, there could be difference between remote controller's desired temperature and air-conditioner body's desired temperature. • Sleep reservation operates as off reservation for the product whose temperature adjustment isn't controlled by unit of 0.5°C. 50 New Wide Wired Remote Controller 6 Press button to finish setting. Ownerʼs & Installation Manual 51 ENGLISH Programming - Sleep Reservation Sleep reservation is the function of air-conditioner to run and stop after certain period of time at sleep mode before sleep. When connected to a ventilation product and set the sleep reservation, when it goes to the sleep mode, after the set time has elapsed. Owner's instruction Owner's instruction ENGLISH Programming - OFF Reservation Automatically turned Off at reserved time that you set. button to exit. 7 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. - If reservation is set, 'turned on' indication shows up at the lower part of LCD screen, and air-conditioner product runs at the time that is set. - If reservation is cancelled, 'turned on' indication disappears. 1 Press button. Ex) Setting OFF Reservation Time as 'AM 10:20'. pressing button 2 Repeatedly to enter the OFF reservation setting mode. ( segment flashing) 3 Press setting. button to adjust AM/ PM button to shift to Hour 4 Press setting mode. When the Hour icon flash, please setting time. The setting range is within 1~12. button to shift to Minute 5 Press setting mode. When the Minute icon flash, please setting minute the setting range is within 00~59. 6 Press 52 New Wide Wired Remote Controller button to finish setting. Ownerʼs & Installation Manual 53 Owner's instruction Owner's instruction ENGLISH Programming : Weekly Reservation You can set the daily reservation in weekly unit. Weekly reservation keeps operating until before you cancel it once you setup button to exit. 7 Press ❈ After setup, it automatically gets out of setup mode if there is no button input for 25 seconds. ❈ When exiting without pressing set button, the manipulated value is not reflected. - If reservation is set, 'turned off' indication shows up at the lower part of LCD screen, and air-conditioner product runs at the time that is set. - If reservation is cancelled, 'turned off' indication disappears. 1 Please move to reservation setup mode by pressing reservation button. ❈ You can setup two weekly reservations for one day, and up to fourteen reservations for a week. For example, to setup (Tuesday morning 11:30 turned on ~ afternoon 12:30 turned off), you setup in order below. move to 'weekly' by 2 Please repeatedly pressing reservation button. 'Weekly' blinks at this time. select weekly reservation or 3 Please weekly reservation ¡ by using button. ❈ You can setup two reservations, weekly reservation 1 and weekly reservation 2, for a day. move to 'date' setup part by 4 Please using button. If 'date' indication blinks, please setup date. You can setup date from Monday to Sunday. move to 'AM/PM' setup part 5 Please of turning on by using button. move to 'hour' setup part of 6 Please turning on by using button. - It is the part to setup the time at which air-conditioner is turned on. change time by using button. 7 Please - You can setup hour 0~12. 8 Please move to 'minute' setup part of turning on by using 9 If 'minute' indication blinks, please setup 'minute' by using 54 New Wide Wired Remote Controller button. button Ownerʼs & Installation Manual 55 Owner's instruction Owner's instruction ENGLISH Programming : Holiday Reservation move to 'AM/PM' setup part 10 Please of turning off by using button. It automatically stops at reserved day that you set. - AM/PM setup is identical with turning on time setup. press button. 1 Please It enters into reservation setup mode. move to 'holiday' by repeatedly 2 Please pressing button. 11 Please move to 'hour' setup part of turning off by using Right button. - It is the part to reserve the time at which air-conditioner is turned off. - If 'hour' indication blinks, please setup 'hour'. move to 'date' that 3 Please you want to setup holiday by using ❈ Please setup 'hour' and 'minute' identically with the method to setup turning on time. button. or cancel holiday by using 4 Pleaseorappointbutton. finishing weekly reservation setup, please press setup/cancellation button. 12 IfWeekly reservation setup for the day that you set is finished. For example, when you setup Monday/Friday to holiday - 'Monday', 'Friday' letter disappears. you setup with the method identical with above by selecting the day that 13 Ifyou'd like to setup, it operates weekly reservation. press 5 Please holiday setup. Weekly reservation explanation Reservation number Turning on time Turning off time button if finishing ❈ If it comes to appointed holiday, air-conditioner automatically stops. Once you setup holiday appointment, until before you cancel holiday setup, air-conditioner automatically stops within one hour even though you run air-conditioner. Under bar: the indication that there is weekly reservation for corresponding day h Indoor unit is turned on to desired temperature if it is configured using up/down button during preset of weekly operation time. (Temperature selection range : 18℃~30℃) - When desired temperature is not set, it is turned on automatically with desired temperature of previous operation. h To cancel all weekly timers, -Pressing set/cancel button while “weekday” display is blinking will cancel the timer. h To cancel the corresponding set individual day of the week, - After selecting the corresponding day of the week, set the ON timer time to be the same as OFF timer time, and pressing set/cancel button will cancel the timer. 56 New Wide Wired Remote Controller Ownerʼs & Installation Manual 57 Owner's instruction Owner's instruction Ventilation Product User Manual - Interlinked operation with general ventilation - When the power is turned on, your remote control recognizes the product (takes about 30 seconds) and then works normally. Single Operation (General Ventilation Single Operation) General Ventilation General Ventilation Wired Remote Controller (Direct Expansion Ventilation Single Operation) Direct Expansion Ventilation Interlinked Operation (General Ventilation Interlinked Operation) General Ventilation Air conditioner Indoor unit Wired Remote Controller (Direct Expansion Ventilation Interlinked Operation) Direct Expansion Ventilation Air conditioner Indoor unit Wired Remote Controller Wired Remote Controller Direct Expansion Ventilation h Connecting wires is the same as air conditioner user manual. (Refer to page about Group control) 2. Press 'Ventilation' button on the wired remote controller and enter Ventilation control mode to check the operation of ventilation product. It is used when air conditioner is interlinked with ventilation product. It is a function that cools and refreshes indoor air using the ventilation product at the same time operating the air conditioning function. Ventilation interlinked operation button on the remote 1 Press controller control panel. - It is only used when air conditioner and general ventilation is interlinked. 'Start/Stop' button at ventilation 2 Pressing mode will start ventilation. button will change the 3 Pressing ventilation operation mode. Pressing operation selection button will change the mode in the order of 'Heat exchange → normal → automatic' ❈ It only displays on the remote controller display when it is in ventilation mode, and it displays the desired temperature when it returns to air condition mode. button in general 4 Pressing ventilation mode will change airflow speed. Pressing airflow speed button will change the mode in the order of 'weak → strong → extra strong'. If CO2 sensor is installed, it can select from 'weak → strong → very strong → automatic'. 3. To convert back to air conditioner mode, press 'Ventilation' button at the ventilation mode. - If no button pressed for 15 seconds or more at ventilation mode, it automatically converts back to air conditioner mode. - Ventilation product represent general ventilation product and direct expansion ventilation product. 58 New Wide Wired Remote Controller back to air conditioner mode 5 Changing 1)Automatic Conversion : when no button is pressed for 15 seconds or longer, it automatically converts back to air conditioner mode. 2) Manual Conversion : Pressing button in ventilation mode will manually convert. Ownerʼs & Installation Manual 59 ENGLISH Ventilation Product User Manual - Interlinked Air conditioner and Ventilation 1. Control using remote controller where air conditioner indoor unit and the ventilation product is installed at the same time. Owner's instruction Owner's instruction Ventilation single operation button on the remote 1 Press controller. button will change 2 Pressing the ventilation mode. Ventilation Remote Controller Contents mode Display Heat Circulate indoor air without loss of heat exchange Directly circulate indoor air without going Normal through heat exchanger Circulate indoor air with automatically Automatic comparing indoor and outdoor air button will change 3 Pressing the strength of the wind - Pressing the button can select from 'weak → strong → very strong'. - If CO2 sensor is installed, it can select from 'weak → strong → very strong → automatic'. Ventilation Product User Manual - Interlinked Operation with Direct Expansion Ventilation It can only be used when the air conditioner is interlinked with direct expansion ventilation product. Interlinked Operation with Direct Expansion Ventilation button on the remote 1 Press controller. - It is used only when air conditioner and the ventilation product are interlinked. ('Interlinked operation' displayed on the remote controller display) button in ventilation 2 Pressing mode starts ventilation. button in ventilation 3 Pressing mode will change the ventilation mode. - Every time the button is pressed, it changes from 'Heat exchange → normal → automatic'. ❈ The display on the remote controller displays only when it is in ventilation mode, and when it converts to air conditioner mode, it displays the desired temperature. button in ventilation 4 Pressing mode changes the strength of wind. - Pressing the button can select from 'weak → strong → very strong'. back to air conditioner mode 5 Changing 1) Automatic Conversion : when no button is pressed for 15 seconds or longer, it automatically converts back to air conditioner mode. 2) Manual Conversion : Pressing button in ventilation mode will manually convert. 60 New Wide Wired Remote Controller Ownerʼs & Installation Manual 61 ENGLISH Manual Conversion - Pressing ʻVentilationʼ button in ventilation mode will manually convert It is a function to cool and refresh the indoor air using general ventilation product.. Owner's instruction Owner's instruction Ventilation Product Additional Operations - Fast / Power Saving It is a function to operate ventilation function more efficiently through the ventilation additional functions, fast / power saving settings. Direct expansion type ventilation single operation Fast : ventilates fast button on the remote controller. 1 It displays as the figure right side in button in ventilation mode. 1 Press - It converts in the order of 'fast → the direct expansion type ventilation single operation. power saving' in ventilation mode. is blinking on the display, and pressing 2 'Fast'button will stabilize 'fast' icon, and the function is set. button will change the 2 Pressing ventilation mode. Pressing the button converts from 'heat exchange → normal → automatic'. Ventilation Remote Controller Contents mode Display Heat Circulate indoor air without loss of heat exchange Directly circulate indoor air without going Normal through heat exchanger Circulate indoor air with automatically Automatic comparing indoor and outdoor air ❈ The 88 segment display above is only displayed when it is in direct expansion type ventilation single operation and the air conditioner is stopped. button will change 3 Pressing operation mode. - Pressing the button will convert from 'cooling → eating → automatic → stop'. 3 Pressing settings. button will exit the Power Saving : efficiently ventilates and performs power savings. button in ventilation mode. 1 Press - It converts in the order of 'fast → power saving' in ventilation mode. Saving' is blinking on the display, and 2 'Power pressing button will stabilize 'Power Saving' icon, and the function is set. button in ventilation 4 Pressing mode changes the strength of wind. - Pressing the button can select from 'weak → strong → very strong'. ❈ Cooling/heating operation selection and the desired temperature can be adjusted in direct expansion type ventilation single operation. ❈ Refer to the basic operation - temperature adjustment for changing desired temperature. 62 New Wide Wired Remote Controller 3 Pressing settings. button will exit the ❈ General ventilation and direct expansion ventilation have the same additional functions. ❈ Ventilation/Heater/Humidifier additional function settings are the same as air conditioner. Ownerʼs & Installation Manual 63 ENGLISH Ventilation Product User Manual - Single Operation with Direct Expansion Ventilation Pressing It performs ventilation operation with cooling or heating at the same time using the heat exchanger inside the direct expansion type ventilation product. Owner's instruction Owner's instruction Ventilation Product Reservations Settings Delay Time : It operates after delay time in ventilation operation. 1 Press Settings button. Sleep Reservations : Sets to operate ventilation lightly during the sleep. button to enter the 1 Press reservation settings mode. button again to move to Sleep. 2 Press 'Sleep' icon blinks and the reservation time is 2 Pressing button repeatedly will move to the delay time menu. Then delay time icon is displayed, and the delay time blinks at the perature display area. displayed. button to set the 3 Use reservation time. Reservation time can be set between 1 ~ 12 hours. button will 3 Pressing change the delay time settings. ❈ Boundary of delay time settings : 00 ~ 60 minutes (in the units of 1 minute) the desired delay time is 4 When displayed, press button to finish the settings. 5 Press button when the setting is finished. ❈ If no button input for 1 minute after the setting, it exits the settings mode automatically. ❈ When exiting without pressing set button, the manipulated value is not reflected. Lock, Filter Cleaning, Time Setting, Converting Temperature h Refer to 'Function Settings - Lock Settings' part for lock function. h Refer to 'Function Settings - Filter Cleaning Display Release' part for Filter Cleaning function. h Refer to 'Function Settings - Time Settings' part for Time Setting function. h Refer to 'Function Settings - Temperature Conversion' part for Temperature Conversion function. 64 New Wide Wired Remote Controller Sleep reservation setting is 4 When finished, press button. button will exit the 5 Pressing settings mode. ❈ If no button input for 60 seconds after the setting, it exits the settings mode automatically. ❈ When exiting without pressing set button, the manipulated value is not reflected. - When the reservation is set, 'Sleep' is displayed at the bottom of LCD screen. - When the reservation is cancelled, 'Sleep' mark disappears. the sleep reservation setting is finished, 6 When it operates lightly for the set time. Simple, ON, OFF, Weekdays, Holidays Reservations h Please refer to the Reservation Settings part of the air conditioner for Simple, ON, OFF, Weekdays, Holidays Reservations Ownerʼs & Installation Manual 65 ENGLISH Ventilation Product Function Settings Owner's instruction Owner's instruction Different mode drive CAUTION - Installer setting mode is a mode to set the detail functions of the remote controller. - When the installer settings are not set properly, it may cause the fault of the product, injury to the user, or damage to the property. - It must be set by a certified technician, and when it is installed without certified technician or changed discretionally, all of the problems are the responsibilities of the installer, and we do not provide service free of charge. 1 Press mode. Different mode drive is a phenomenon taking place when indoor units' drive mode is different in the case that a few indoor units are set up at one AHU. (Different mode drive doesn't show up at cooling exclusive model.) a few indoor units are running air-cooling 1 While at one AHU, it doesn't operate heating drive if one indoor unit operates heating drive. button to enter ventilation button down for more 2 Pressing than 3 seconds will enter the settings mode. - Pressing once shortly will enter the user settings mode. You must press down for more than 3 seconds. a few indoor units are running heating 2 While at one AHU, it doesn't run if one indoor unit runs cooling or humidity removal. It is the indication that it is operating heating drive at AHU. you enter the installer settings mode, 3 When the data value that can be set is displayed at the lower right corner of LCD screen. Code value Seting value pressing button, indoor unit 3 Ifautomatically runs at the mode that different indoor units are running after about 5 seconds and operates. • Some categories of the menu may not be displayed according to the function of the product, or the menu name may be different. Simple, ON, OFF, Weekdays, Holidays Reservations h Please refer to the Reservation Settings part of the air conditioner for Simple, ON, OFF, Weekdays, Holidays Reservations 66 New Wide Wired Remote Controller Ownerʼs & Installation Manual 67 ENGLISH Ventilation Product Installer Setting Functions - Entering Method Owner's instruction ENGLISH Checkups before reporting breakdown Please first check the items below for product's defects before consulting to service center. Symptoms It has no power on. It doesn't operate reservation drive. It doesn't release cool wind. Air-conditioner automatically runs or stops. Error is indicated on remote controller indication window. Check-up Management • Is air-conditioner's power on? • Please check up circuit breaker. • Please check up wire remote controller's setup condition. • Are air-conditioner and remote controller properly connected with cable? • Please connect air-conditioner and remote controller cable. • Is cable connection correct? • Please check again referring to setup method at the manual. • Did you correctly setup time? • Please set up current time correctly. • Did you correctly make a reservation? • Please set up again referring to the manual. • Is desired temperature setup lower than current temperature? • Please set up desired temperature lower than current temperature. • Isn't reservation drive setup? • When reservation setting button and set/cancel button are pressed simultaneously for 3 seconds or longer, all set reservations will be cancelled. • Does remote controller indication window indicate 'CH03'? • Please check again wire remote controller's setup condition. • Please check again connection condition of air-conditioner and remote controller cable. 68 New Wide Wired Remote Controller Ownerʼs & Installation Manual 69
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project