LG | PQNUD1S00.ENCXLEU | LG PQNUD1S00.ENCXLEU Owner’s Manual

ENGLISH
ITALIANO
ESPAÑOL
FRANÇAIS
DEUTSCH
CHINESE
OWNER’S MANUAL
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : POWER DISTRIBUTION INDICATOR
MODELS : PQNUD1S00
P/NO : MFL37115811
www.lg.com
Power Distribution Indicator Owner's & Installation Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Cautions for safety ......................3
Model #
Overview ......................................6
Serial #
Available Watt-hour meter ..........7
You can find them on a label on the side of each unit.
Dealer's Name
Wiring Diagram ............................8
Date Purchased
Internal Wiring Diagram ............12
■ Staple your receipt to this page in the event you need
to prove date of purchase or to issue warranty.
Installation ..................................13
How to set interface unit ...........19
How to set each Indoor Unit .....20
Installation Guide.......................26
Usage ..........................................27
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your Power Distribution Indicator properly.
Just a little preventive care on your part can save you a
great deal of time and money over the life of your
Power Distribution Indicator.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
2 Electricity Distribution Indicator
Cautions for safety
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to properties only.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
■ WHEN INSTALLING
You should always request
product installation to our
Service Center or to
installation expert agency.
• Otherwise it may cause
fire hazard, electric shock,
explosion, injury or
damage.
Use specified parts.
• Or else it may cause fire
hazard, electric shock,
explosion, injury, damage
and trouble failure.
When reinstalling an existing
installed product, request it to
our Service Center or to
installation expert agency.
• Otherwise it may cause fire
hazard, electric shock,
explosion, injury or damage.
SPECIFIED
PARTS
Donʼt keep or use ignitable gas or any other
flammable material in vicinity of the product.
• Otherwise it may cause fire hazard and
product trouble failure.
Donʼt disassemble, repair and modify the
product at your will.
• Or else it may cause fire hazard and electric
shock.
ene� Ether Thinner
Benz
�
Userʼs Manual 3
ENGLISH
Cautions for safety
Cautions for safety
Donʼt install it where rain falls on.
Donʼt install it in humid place.
• Otherwise it may cause product failure.
• Otherwise it may cause product failure.
■ WHEN USING
Donʼt change or extend
electric supply wire at your
will.
• Or else it may cause fire
hazard and electric shock.
Donʼt spill water into interior
of the product.
• Otherwise it may cause
electric shock and product
failure.
Always request to our Service
Center or installation expert agency
in such case as the product has
been submerged under water.
• Or else it may cause fire
hazard and electric shock.
Donʼt let there exist fire heat
near the product.
• Otherwise it may cause fire
hazard.
Donʼt put heavy material upon
electricity supply chord.
• Or else it may cause fire
hazard and electric shock.
Child or the old and the weak
shall use it under custody of
patron.
• Otherwise it may cause
safety accident or product
failure.
4 Electricity Distribution Indicator
Donʼt use heat equipment
near the electricity supply
line.
• Or else it may cause fire
hazard and electric shock.
Donʼt put heavy material
upon the product.
• Or else it may cause
product trouble failure.
Donʼt give impact to the
product.
• If the product is impacted,
it may cause product
trouble failure.
Cautions for safety
ENGLISH
■ WHEN USING
Donʼt clean the product with
strong detergent of solvents
but only use soft cloth.
• Or else it may cause fire
hazard and product
deformation.
If water has been smeared
on electric charge part, use
it after removing water.
• Or else it may cause
product failure.
Donʼt let metallic products
of necklace, coin, key, watch
etc. touch the battery
terminal.
• Or else it may cause product
failure and injury.
x
Wa Thinner
Userʼs Manual 5
Overview
Overview
■ Functions
• Accumulation of total power consumption
• Indication of current power in use
• Indication of accumulated power for period
• Indication of standby power (option setting)
■ Specification
• Power Supply: 220~240V AC 50/60HZ 1Ø
• Dimension: 200mm (W) X 120mm (H) X 55mm (D)
• Connectable Units: 1 Outdoor Unit per Electric Power Distribution Indicator.
■ Count Method for Electric Power Distribution
• Power Consumption of each Indoor Unit = Power Consumption of Outdoor Unit x [Weighting Power of each
Indoor Unit / Weighting Power of total Indoor Units]
• Weighting Power of each Indoor Unit = Operation (On/Off) x [ Capacity of Indoor Unit X LEV open rate X Fan
step of Indoor Unit ]
6 Electricity Distribution Indicator
Overview
ENGLISH
■ Parts of a PDI
1
2
3
4
5
6
1. Indicator LCD Display
2. Name Plate of each room
3. Menu Button
4. Up and Down Button
5. Right Shift Button
6. SHIFT Button for LCD Screen Change
Available Watt-hour meter(Local purchase)
• Use the digital watt meter which send the pulse signal depending on the power consumption.
• Use watt meter of 1W/pulse, 2W/pulse, 4W/pulse, 6W/pulse, 8W/pulse or 10W/pulse
or PT/CT Type (pulse width: 40 –400 msec).
Userʼs Manual 7
Wiring Diagram
Wiring Diagram
■ Independent operation of PDI
- Connect the product as shown in the below connection diagram
1. MultiV / MultiV PLUS
3Ø 380VAC or
1Ø 220VAC
Watt meter
Address setup
Pulse type
Start -> End
(00) -> (03)
PDI
1Ø
220VAC
PI-485
MultiV/MultiV PLUS
Outdoor unit
(00)
(01)
(02)
(03)
Indoor unit address setup
2. Multi V PLUS2 or 3 series
Watt meter
3Ø 380VAC
Pulse type
PDI
AC220V
OUT FAN(A)
Internet A
OUT FAN(B)
Internet B
1Ø 220VAC
Multi V
(PI485 is embedded
at the Outdoor unit)
(00)
(01)
(02)
Indoor unit address setup
8 Electricity Distribution Indicator
(03)
Wiring Diagram
ENGLISH
3. MPS multi Product
3Ø 380VAC or
1Ø 220VAC
Watt meter
Address setup
Pulse type
Start -> End
(00) -> (03)
PDI
1Ø
220VAC
PI-485
MPS multi
Outdoor unit
(00)
(01)
(02)
(03)
Indoor unit address setup
❈ NOTE : In connecting Multi product
PI-485 must be connected for PDI. (PI-485 must be purchased separately.)
Userʼs Manual 9
Wiring Diagram
■ Operation with PC Central controller or ACP
- Connect the product as shown in the below connection diagram.
Address setup
Start -> End
(00) -> (03)
Watt meter
3Ø 380VAC or
1Ø 220VAC
PDI
Slave
Setting
PI-485
Multi/ Multi V Outdoor unit
Address setup
(00)
(01)
(02)
Start -> End
(7C) -> (7F)
(03)
Indoor unit
address setup
Watt meter
PDI
Slave
Setting
PI-485
Multi/ Multi V Outdoor unit
ACP
(7C)
(7D)
(7E)
ACSMART
(7F)
Indoor unit
address setup
LAN
LA
L
AN
AN
Or
❈ NOTE
Multi V PLUS 2 or 3series Product does not need PI485 to operate PDI. But, Multi Product must connect PI485
to operate PDI. (PI485(PMNFP14A0) must be purchased separately)
10 Electricity Distribution Indicator
Wiring Diagram
ENGLISH
■ Operation with LG Web PDI (PQCPM11A0)
- Connect the product as shown in the below connection diagram.
Address setup
LG-NET 1
LG-NET 2
1
2
DI
LG-NET 3
3
4
LG-NET 4
5
TX
RX
TX
RX
TX
RX
TX
RX
7
8
9
10
11
12
13
14
15
16
17
18
19
20
FDD
Ext.
Ethernet 1
MENU/
SELECT
Ethernet 2
Console
1
2
DO
Start -> End
(00) -> (03)
Watt meter
6
TX
RX
TX
RX
ACT
LNK
ACT
LNK
TX
RX
3Ø 380VAC or
1Ø 220VAC
Run
3
Power
4
Slave
Setting
Web PDI
PDI
PI-485
Multi/ Multi V Outdoor unit
Address setup
(00)
(01)
(02)
(03)
Indoor unit
address setup
Start -> End
(7C) -> (7F)
Watt meter
PDI
Slave
Setting
PI-485
Multi/ Multi V Outdoor unit
(7C)
(7D)
(7E)
(7F)
LG-NET 1
LG-NET 2
Indoor unit
address setup
1
2
DI
LG-NET 3
3
4
LG-NET 4
5
TX
RX
TX
RX
TX
RX
TX
RX
6
or
7
8
9
10
11
12
13
14
15
16
17
18
19
20
FDD
Ext.
MENU/
SELECT
ACT
LNK
ACT
LNK
Console
1
2
DO
TX
RX
TX
RX
Ethernet 1
Ethernet 2
TX
RX
BMS
Run
3
4
Power
❈ NOTE
Multi V PLUS 2 or 3series Product does not need PI485 to operate PDI. But, Multi Product must connect PI485
to operate PDI. (PI485(PMNFP14A0) must be purchased separately)
When PI-485 is off, PDI cannot work.
Userʼs Manual 11
Internal Wiring Diagram
Internal Wiring Diagram
■ Install the product as per the following wiring diagram
PI-485
Multi V
...
PDI
Indoor unit
Power
220~240V/AC
50/60 Hz
Watt-hour meter
+
WHM
Multi V or PI485
Remote Reading
Device (Option)
INT. B
INT. A
TX : A
BUS B
BUS A
B
A
RX : B
BLACK
(-)
(+)
+
CN_OUTFAN
WHITE
CN_PC
CN_WATTMETER
CN_POWER
The color and polarity of the communications line can differ
from what’s indicated on the PCB depending on the
manufacturer of watt meter. [ Black -> (+), white -> (-) ]
• Turn on the power after connecting the product.
12 Electricity Distribution Indicator
Installation
ENGLISH
Installation
How to set Option
1. You must start the key operation within 10 minutes after
turning on the power for setting options.
2. When you press the Menu and Shift key at the same time,
the following option screen will be shown.
Initial Screen
ELECTRIC POWER
DISTRIBUTOR
Press Menu and Shift
at same time
Option setup screen
1 1 0 0 0 0 0 0 0 U n i t
1 W / p
M I C R O N I C
S T B P
N O -
• Product selection When the first two digits flash, you can use the ▲ or ▼ key to set the product.
[00] -> Unit (When using in connection with indoor communication Line Of MultiV / MultiV PLUS)
[10] -> Slave (when using in connection with central controller)
[11] -> Master (when not using in connection with central controller)
Ex) Product selection: Master, Watt meter: 1W/1 pulse
[11] : Independent operation of PDI
1 1 0 0 0 0 0 0 0 M a s t e r 1 W / p
M I C R O N I C
N O -
S T B P
Userʼs Manual 13
Installation
- After setting the product, press ▶ to select the next option.
LGAP
Press the ▶ key to set up
the Option for remote
reading service company
selection.
• Remote reading service company selection
(Don't care selecting remote reading service ID.)
- When two digits flash, use the ▲ or ▼ key to select the remote reading service
company.
[000] -> MICRONICS / [001] -> LSIS-COM
[010] -> CI-TOPIA
/ [011] -> OMNI-SYS
[100] -> LG-ACP (for WEB PDI)
[000]
110000000Master1
MICRONIC
W/p
NO- STBP
✱ This setting does not care to use PDI
- After setting the product, press ▶ to select the next option.
14 Electricity Distribution Indicator
Installation
ENGLISH
- After setting the product, press ▶ to select the next option.
Press the ▶ key to set up
the option for watt meter
selection.
LGAP
• Watt meter selection
- When the third 3 digits flash, use the ▲ or ▼ key to select the meter constant of the
watt meter.
[000] ->
[010] ->
[100] ->
[110] - >
1 wh/ Pluse
/ [001] ->
4 wh/ Pluse
/ [011] ->
8 wh/ Pluse
/ [101] ->
PT/CT : In case of CT using.
2 wh/ Pluse
6 wh/ Pluse
10 wh/ Pluse
Ex) Product selection: Master, watt meter: 2W/ pulse
[001] is set to 2W/pulse and shows the
meter constant of the watt-hour meter.
1 1 0 0 0 0 0 1 0 M a s t e r 2
MICRONIC
W / p
NO- STBP
- After setting the product, press ▶ to select the next option.
Ex) In case of CT (Current Transformer) using.
- CT ratio 20 : 1
- Watt-hour meter : 2500 Pulse/kWh
1 1 0 0 0 1 1 0 0 M a s t e r PT/CT
MICRONIC
NO- STBP
After setting PT/CT(110),
press ‘SHIFT’ key.
When the first digit flashes, use the ▶ key to shift cursor right.
And you can use the ▲ or ▼ key to set value of CT & watt-hour meter.
Input
I n [P u l s e / k W h ]
CT: 0 0 0 2 0 / P r : 0 2 5 0 0
After setting value of
CT & watt-hour meter,
press ‘SHIFT’ key.
Userʼs Manual 15
Installation
Press the ▶ key to select
the option for standby
power.
LGAP
• Standby power indication selection
- When the forth digit flashes, use the ▲ or ▼ key to select the standby power.
[0] NO-STBP -> Does not show the standby power
[1] CAL-STEP -> Shows the standby power
• Note : If the PDI has been set Slave in previous option selection then Certainly Set
NO-STBP
Ex) Product selection: Master, standby power indication selection
[1] is set to CAL-STBP and
shows you the standby power.
1 1 0 0 0 0 0 0 1 M a s t e r 1
MICRONIC
W / p
CAL- STBP
✱ What is standby power selection function?
: Standby power refers to the electric power consumed by the product after the
operation of the product is turned off.
It is the function of separately saving the power consumed when all heating and
air conditioning indoor units are turned off.
16 Electricity Distribution Indicator
Installation
ENGLISH
LGAP
3. After setting the option, press the Shift key to enter the
remote reading service ID setup mode.
(In case of selecting reading service ID in )
• This function is applicable to only korean marcket (Domestic)
So, skip this setting in the procedure for overseas marcket
Press the "SHIFT" key
- When the first two digits flash, use the s or t key to select the remote reading service ID by company.
CI-TOPIA ID setup
OUT DR ID(CITOPIA)
XX
OMNI SYS ID setup
OUT DR ID(OMNI-SYS)
XXXX
MICRONICS ID setup
OUT DR ID(MICRONIC)
XX
LS lS ID setup
OUT DR ID(LSIS)
XXXX
LG Web PDI setup
OUT DR ID(LG-ACP)
XXXX
✱ When setting the remote reading service ID, enter the remote reading service ID
assigned by the remote reading service company.
4. After entering the remote reading service ID, press the Shift
key to enter the indoor address selection mode.
(In case of the selecting "Master/Slave")
Userʼs Manual 17
Installation
Press the Shift key to enter the
indoor selection mode
Initial Screen
LGAP
(Start)
->
(End)
(00)
->
(00)
• You can select the option for indoor address selection mode only when
Master / Slave is selected.
• You can distribute the using power to maximum of 64 indoor units.
(When showing the stand by power, maximum of 63 indoor units.)
- If the PDI connects to 64 indoor units, set the addresses of indoor units from 00 to 3F.
(Central control address : 00~3F)
(Start)
->
(End)
(00)
->
(3F)
Ex) If addresses of indoor units are set by “12”, “13”, “14” and “15”,
set start address by “12” and set end address by “15”.
(Start)
->
(End)
(12)
->
(15)
- Press the Menu key to save the remote reading service ID and return to the
initial screen.
18 Electricity Distribution Indicator
Installation
ENGLISH
How to set Interface unit
PI-485
Select Air
Conditioer Type
Select Network Type
Select Advanced Control Type
ON KSDO4H
L1 2 3 4
Multi V & Multi(LGAP applied) products Configuration Methods
ON
➔ 1 ON, All others OFF: Multi V products(Except CRUN products) or Multi
(Non-Inverter) Product applied Common PCB(Refer to NOTE) or
Multi(Inverter) Product + Central Controller(All types) - Without LGAP
ON
➔ 1 and 4 ON, All others OFF: Multi V products(Except CRUN products) or
Multi(Non-Inverter) Product applied Common PCB or Multi(Inverter) Product +
Central Controller(All types) - Using LGAP
ON
➔ 2 ON, All others OFF: Multi(Non-Inverter) Product
+ Centroller(All types) - Without LGAP
ON
➔ 2 and 4 ON, All others OFF: Multi Non-Inverter Product
+ Central Controller(All Types) - Using LGAP
ON
➔ 1,2,3,4 ON : Multi V CRUN Product
+ Central Controller(All types) - Using LGAP
• Please refer the corresponding Central Controller installation manual if you want to know
whether your Central Controller is compatible with LGAP or not.
CAUTION
The wrong setting of air-conditioner switch could cause malfunctioning.
Switch setting must be done carefully.
Push the Reset button after changing the Dip switch.
NOTE : Multi(Non-Inverter) Product applied Common PCB
PCB P/NO. : 6871A20917*
P/NO. : 6871A20918*
P/NO. : 6871A20910*
Userʼs Manual 19
How to set Interface unit
How to set each Indoor Unit
■ Using wired remote controller
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
SUB FUNCTION
AUTO Heater
Defrost
JET
Filter
ZONE
1 2
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Preheat
Humidify
Out door
3 4
Program set
05
07
09
11
13
15
17
19
21
1. Press the "Program" &
"Set/Clr" keys at the same
time.
23
2. Set up the indoor address
using the temperature
adjustment key
Timer
Cancel
Program
Week
☛ Setup range: 00-7F
Holiday
Program
Plasma
3
A
Set/Clr
Hour
Min
RESET
Group No. Indoor No.
Set/Clr
3. Press the "Program" & "Setup/Clr" keys at the same time
for 3 seconds to set up the indoor address.
• The room address on the PDI is listed in the ascending order of indoor number.
Ex) If the indoor addresses are "7C", "7D", "7E" and "7F", the order of the indoor unit on the
PDI are "1", "2", "3" and "4".
• The indoor numbers must be entered in sequence to be accurately recognized in the PDI.
Ex) Correct indoor unit address setup: "01", "02", "03" (setup in order)
Incorrect indoor unit address setup: "01", "02", "06"
20 Electricity Distribution Indicator
How to set each Indoor Unit
ENGLISH
pressing
button long for 3
1 Ifseconds,
it enters into remote
controller setter setup mode.
- If pressing once shortly, it enters
into user setup mode. Please press
more than 3 seconds for sure.
into address setup mode by using
2 If entering
button, it indicates as picture below.
Indoor No.
Group No
Function Code
Group No. by pressing
3 Set
button.(0~F)
to Indoor No. setting option
4 Move
by pressing
button.
Indoor No. by pressing
5 Set
button.
6 Press
button to save.
button will exit settings mode.
7 Pressing
❈ After setup, it automatically gets out of
setup mode if there is no button input for
25 seconds.
❈ When exiting without pressing set button,
the manipulated value is not reflected.
Userʼs Manual 21
How to set each Indoor Unit
the
button for 4
1 Press
seconds to enter the installer
setting mode until timer segment
display "01:01".
pressing
2 Repeat
Function code 02.
button to select
Indoor No.
Function Code Group No
Ex) Setting Address as 'F5'
Group No. by pressing
3 Set
button.
to Indoor No. setting option
4 Move
by pressing
button.
Indoor No. by pressing
5 Set
button.
6 Press
button to save or release.
button to exit or system will
7 Press
automatically exit after 25 seconds
without any input.
22 Electricity Distribution Indicator
How to set each Indoor Unit
ENGLISH
■ Using wireless remote controller
1. Address setting mode
1) With the top left key pressed, press the Reset button.
(Press the left key for more than 3 second)
2) Using the temperature adjustment key, set up the indoor unit
address
❉ Setup range: 00-7F
ex)
• No use For Power Distribution Indicator
• Used for Central Control settings
Address
check
ON
OFF
SET
CANCEL
Address
setting
3
A
PLASMA
3) After setting the address, press the On/Off key once
directing the remote controller to the indoor unit.
4) When indoor unit shows the setting address, the address
setup is complete.
(The time and method of the address display can differ
depending on the indoor unit type.)
5) Reset the remote controller and use it.
2. Address check mode
1) With the top right key pressed, press the Reset button.
(Press the left key for more than 3 seconds.)
2) Press the On/Off key once directing the remote controller to the indoor unit.
The indoor unit shows the setting address and the address setup is completed.
(The time and method of the address display can differ depending on the indoor unit type.)
3) Reset the remote controller and use it
❉ Depending on the manufactured date of the wired/ wireless remote controller, the above
function might not work.
Since this is a function not relevant for consumer in using the product, setup the remote
controller to enable address setup during installation.
❉ When setting the address, refer to the details on the previous page.
Userʼs Manual 23
How to set each Indoor Unit
1
When RESET button is pressed once with JET COOL button
held, ʼ00ʼ will be shown on the LCD DISPLAY and itʼll enter
into the address set mode.
2
Whenever you press the Temperature Increase(UP) button,
the group address number also increases.(Left-digit)
And whenever you press the Temperature Decrease(DOWN)
button, the indoor-unit address number also increases.
(Right-digit) (Control scope of Group Address No. and Indoorunit Address No. : 00~FF)
To raise the temperature
(00, ...., 90, A0, ...., F0)
To lower the temperature
CANCEL
ON
OFF
(00, ...., 09, 0A, ...., 0F)
SET
AUTO CLEAN
3
When you press the START/STOP button on your remotecontroller directed toward the receiver of indoor-unit after
setting address, the address would be set.
(Address No.3 indoor-unit
of Second Group)
4
When you press RESET button after completing address
setup, the address setup function will be cancelled.
In the state of cancellation, LCD display shows the initial
standby mode.
NOTICE
❏ You are recommended to follow below procedure to check indoor-unit address with remotecontroller.
Press RESET button once with the wind direction button(
) of remote-controller held.
The LCD DISPLAY on remote-controller shows ʼ88ʼ. When you press START/STOP button
on your remote-controller directed toward the receiver of indoor-unit at this time, the display
LED of indoor-unit lights at the initial set address.
24 Electricity Distribution Indicator
How to set each Indoor Unit
With the MODE button pressed, press the RESET button.
2
By using the TEMPERATURE SETTING button, set the indoor unit address.
- Setting range : 00 ~ FF
Group No.
Indoor Unit No.
3
After setting the address, press the ON/OFF button toward the
indoor unit 1 time.
4
5
The indoor unit will display the set address to complete the address setting.
- The address display time and method can differ by the indoor uint type.
Reset the remote controller to use the general operation mode.
Installer Setting - Checking Address of Central Control
1
With the PLASMA button pressed, press the RESET button.
2
Press the ON/OFF button toward the indoor unit 1 time, and the indoor unit will display the set
address in the display window.
- The address display time and method can differ by the indoor unit type.
3
Reset the remote controller to use the general operation mode.
Userʼs Manual 25
ENGLISH
1
Installation Guide
Installation Guide
Power Distribution Indicator and WHM should be installed in the specified cabinet which can protect the
Power Distribution Indicator from water and humidity.
EX1)
EX3)
EX2)
EX4)
✱ NOTE : WHM (Watt-hour meter)
• Suppl power after completing the Wiring
• Set the Power Distribution Indicator so as to fit the usage condition.
26 Electricity Distribution Indicator
Usage
ENGLISH
Usage
(The distributed power consumption is based on current operating condition)
• Press the Menu key once to display the current power consumption.
• Consecutively press the Menu key to switch the screen.
• The PDI will operate normally after 3 minutes, when all options are set .
1. PWR distribution mode
Initial Mode
PWR Distribution Display Mode
Press “Menu” key
LGAP
LGAP
Accumulated PWR Display Mode
Press “Menu” key
Press “Menu” key
Press “Menu” key
Period Accumulated PWR Display Mode
• It displays the current power consumption of each indoor unit(Watt/hour)
• When 1-2 indoor units are connected, only 1 page is displayed.
• When 4 or more indoor units are connected, press the "Shift" key to check the next page.
Total SUM Value
PWR
Dist(01)XXXX.X
XX)XXXX.X
Indoor 1 Value
Press
Shift key
XX)XXXX.X
Indoor 2 Value
Total SUM Value
PWR
Dist(02)XXXX.X
XX)XXXX.X
Indoor 3 Value
XX)XXXX.X
Indoor 4 Value
Userʼs Manual 27
Usage
• When selecting the option for classifying the stand by power, the stand by power is displayed in the last
page.
The stand by power page
PWR
Dist(00)0000.0
STBP:
0 0 0 0 . 0
Stand by power
2. ACCUMPWR distribution mode
• It displays the accumulated power consumption of each indoor unit (Kwh)
• When 1-2 indoor units are connected, only 1 page is displayed.
• When 4 or more indoor units are connected, press the Shift key to check the next page.
Total SUM Value
ACC
PWR(01)XXXXX.X
XX)XXXXX.X
Indoor 1 Value
Press
Shift key
X X ) X X X X X . X
Indoor 2 Value
Total SUM Value
ACC
PWR(02)XXXXX.X
XX)XXXX.X
Indoor 3 Value
X X ) X X X X X . X
Indoor 4 Value
• When selecting the option for classifying the stand by power, the stand by power is displayed in the last
page.
The stand by power page
ACC
PWR(00)0000.0
STBP: 0 0 0 0 . 0
Stand by power
28 Electricity Distribution Indicator
Usage
ENGLISH
3. Period accumulated power distribution mode
• It displays the power consumption of each indoor unit (Kwh)
• When 1-2 indoor units are connected, only 1 page is displayed.
• When 4 or more indoor units are connected, press the Shift key to check the next page.
Total SUM Value
Perid
ACCM(01)XXXX.X
XX)XXXX.X
Indoor 1 Value
Press
Shift key
X X ) X X X X .X
Indoor 2 Value
Total SUM Value
Perid
ACCM(02)XXXX.X
XX)XXXX.X
X X ) X X X X X .X
Indoor 4 Value
Indoor 3 Value
• Press the ▲ and ▼ key at the same time for 3 seconds to clear the data.
• As the function for manual check, when cleared after the check, it displays the
cumulated power from the clearing point.
• When classifying the stand by power, it is shown after the last page.
The stand by power indication page
Perid
ACCM(00)0000.0
STBP:
0000.0
Stand by power
Userʼs Manual 29
30 Electricity Distribution Indicator
Download PDF