3 ON/OFF TIMER
Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours.
In the first 30 minutes set temperature increases by 1°C and in the next 30 minutes temperature
increases by another 1°C, this temperature then remains till the timer function is deactivated.
4 FAN SPEED SELECTOR
Select the fan speed in Three steps Low (F1) / Med. (F2) / High (F3)
5 ROOM TEMPERATURE SETTING BUTTON
Control the room temperature within a range of 16°C to 30°C.
6 AUTO SWING
The vertical louver swings horizontally by the automatic system and stops when you press the
button again.
7 SIGNAL RECEIVER
8 AIR PURIFIER (For Plasma Model)
Used to start or stop plasma purification system. Clean filter indication will be 'ON' on panel,
when filter cleaning is required.
9 SLEEP BUTTON
Sleep function can be set by one hour for a maximum of 7 hours. In the first 30 minutes set
temperature increases by 1°C and in the next 30 minutes temperature increases by another
1°C, this temperature then remains till the timer function is deactivated. This is how the
sleep function behaves. The fan speed will change to low speed(F1).
Operation modes may vary in select models.
Fan speed in two steps Low (F1) / High (F2) in select models.
AUTO RESTART
In failure of electric power the unit runs as previous setting operat ion when power returns.
NOTE: ‘SLEEP’ and ‘TIMER’ function cannot operate at same time.
How to Insert the Batteries
1 Remove the cover from the back of the remote
controller.
Slide the cover according to the arrow direction.
2 Insert the two batteries.
Be sure that the (+) and (-) directions are correct.
Be sure that both batteries are new.
3 Re-attach the cover.
Slide it back into the position.
04-
Do not use rechargeable
batteries, such batteries differ
from standard dry cells in shape,
dimensions, and performance.
Remove the batteries from the
remote controller if the air
conditioner is not going to be
used for an extended length of
time.
Your Panel may look like any
of below mentioned panels.
3
Mode
Timer
Fan
Cool
22
On
Dry
AUTO
SWING
Fan Speed
FAN SPEED
4
4
TIMER COOLING/FAN
TIMER COOLING/FAN
22
3
3
2
7
2
ENERGY SAVER AUTO SWING
ENERGY SAVER AUTO SWING
2( b)
V
V
UP
5
FAN SPEED
Timer
Type 2
DOWN
UP
6
5
Cool
1
5
Temp
4
Fan
1
ON/OFF
POWER
1
DOWN
V
REMOTE CONTROLLER
POWER
7
Energy Saver
FAN
SPEED
V
Type 1
2
REMOTE CONTROLLER
6
2( b)
6
1
Temp
Power
5
7
FAN
Temp
TEMP
1
5
Power
Mode
1
5
ON
Timer
FAN
SPEED
AUTO
SWING
ON/OFF
4
6
1
V
(e) E N E R G Y S AV E R
2
3
Type 4
TEMP
Temp
88
2
Sleep
Mode
Timer
Auto
Swing
3
5
FAN SPEED
4
4
4
9
5
Fan Speed
Fan Speed
7
COOL
1
5
V
TEMP
Power
8
V
ENERGY SAVER
FAN
Air
Purifier
V
DRY
Type 3
POWER
88
COOL
6
9
2
Sleep
Mode
Timer
Auto
Swing
3
6
MODE
2
AUTO SWING
6
ON/OFF
1
Controls
Precaution: The Remote Control unit will not function properly if strong light strikes the sensor
window of the air conditioner or if there are obstacles between the Remote Control
unit and the air conditioner.
1 POWER BUTTON
Operation starts, when this button is pressed and stops when you press the button again.
2 OPERATION MODE SELECTION BUTTON
Select (a)Cool (b)Energy Saver (c)Fan & (d)Dehumidification (dry) with this button.
Energy saver mode-fan stops when compressor stops cooling. Approximately after 3
minutes fan will turn on to determine it cooling is needed. In dry mode, unit will run at
low fan speed only with compressor ‘ON’.
-9-
Your Panel may look like any of below mentione d panels.
(a)
FUZZY
DRY JET
ENERGY
SAVER
2
4
MODE
(b)
88 88
CLEAN
FILTER
AIR
PURIFIER
CL
INDOOR
DESIRED
9
7
FAN
TEMP
AUTO SWING
TIMER
6
3
10
ON/OFF
5
1
FUZZY
DRY JET
ENERGY
SAVER
2
4
MODE
(c)
88 88
CLEAN
FILTER
AIR
PURIFIER
CL
INDOOR
DESIRED
10
9
7
FAN
TEMP
Air
Purifier
TIMER
8
3
ON/OFF
FUZZY
DRY JET
ENERGY
SAVER
3
7
1
CLEAN
FILTER
AIR
PURIFIER
CL
INDOOR
DESIRED
FAN
SPEED
TEMP
ON/OFF
AUTO
SWING
2
1 POWER (ON/OFF) BUTTON
Operation starts, when this button is pressed and stops when you press the button again.
2 OPERATION MODE SELECTION BUTTON
Select (a) Cool, (b) Energy Saver, (c) Fuzzy & (d) Dry. In dry mode, unit will run at low fan speed only
with compressor 'ON'. When compressor is 'OFF', fan will be off.
During Energy Saver mode, fan stops when compressor stops cooling. Approximately after 3 minutes
fan will turn ON to determine if cooling is needed. If cooling is not needed, the fan turns OFF again.
3 ON/OFF TIMER
Set the time of on/off operation. The timer can be set by the one hour for a maximum of 12 hours. In case of Auto
Restart, ON/OFF Timer is automatically cancelled.
4 FAN SPEED SELECTOR
Select the fan speed in Three steps Low / Med / High
5 ROOM TEMPERATURE SETTING BUTTON
Control the room temperature within a range of 18°C to 30°C.
6 AUTO SWING
The vertical louver swings horizontally by the automatic system and stops when you press the button again.
7 SIGNAL RECEIVER
8 FOR PLASMA MODEL- AIR PURIFIER
Used to Start or Stop the Plasma Purification function.
9 CHILD LOCK
Child Lock is used to prevent children from changing the settings of the unit. It can be activated when the
unit is ON by pressing the Fan Key (4) and the Timer Key (3) simultaneously for 5-10 seconds. When the
Child Lock is active, icon 'CL' lights upon the control panel. Now, the keys on the Control Panel and the
Remote Controller will stop working. To deactivate the Child Lock, press again the Fan Key (4) and the
Timer Key (3) simultaneously for 5-10 seconds. When Child Lock is deactivated icon 'CL' goes off on the
Display Panel.
10 CLEAN FILTER
a. In case when CLEAN FILTER indication is 'ON' on the Control Panel, the Plasma Pure Filter (For select
models) needs to be cleaned. Turn 'OFF' the unit and remove Plasma Filter by opening the grill. Then
clean the filter and replace it back to it original position. After this close the grill and turn 'ON' the unit.
The CLEAN FILTER indication goes 'OFF' on the Display Panel. In case it doesn't reset the unit.
b. In case when CLEAN FILTER indication is blinking on the Control Panel, the Anti-Bacteria / Deo-Air Filter
needs to be cleaned. Turn 'OFF' the unit and remove the filter by opening the grill. Then clean the filter
and replace it back to the original position. After this close the grill and turn 'ON' the unit. Then press
the Temperature Down key (5) continuously for 5 seconds. The CLEAN FILTER indication goes 'OFF'
on the Control Panel.
Operation modes may vary in select models.
Fan speed in two steps Low (F1) / High (F2) in select models.
AUTO RESTART
In failure of electric power the unit runs as previous setting operation when power returns.
-10-
10
9
TIMER
MODE
5
88 88
4
1
5
6
About the remote control on the system
The remote control transmits the signals to the system.
Features of the Remote Control- Door Closed
Signal transmitter
Signal transmitter
JET COOL TEMP A/SWING
6
5
6
5
FAN SPEED
4
1
Signal transmitter
5
6
1
POWER
4
TYPE A
3
FAN SPEED
2
2
1
4
3
MODE
POWER
TEMP
1
3
2
OL A/SWING
JET CO
3
4
Flip-up door
(closed)
5
6
Signal transmitter
2
ON
Flip-up door
(closed)
TYPE B
MODE
ON
Flip-up door
(closed)
TYPE C
Flip-up door
(closed)
TYPE D
INDOOR FAN SPEED
4 SELECTOR
START/STOP BUTTON
1 Operation
starts when this button is
Used to select fan speed in four steps
Low, Medium, High, or CHAOS*.
pressed and stops when the button is
pressed again.
OPERATION MODE
2 SELECTION
BUTTON
JET COOL
5 Used
to start or stop the speed
ROOM TEMPERATURE
3 SETTING
BUTTONS
6
Used to select the operation mode.
cooling. (Speed cooling operates
high fan speed in cooling mode).
Used to select the room temperature.
AIR SWING BUTTON
Used to stop or start vertical louver
movement.
Precaution: The Remote Control unit will not function properly if strong light strikes the sensor window of the air
conditioner or if there are obstacles between the Remote Control unit and the air conditioner.
Operation Mode
Cooling Mode
Fuzzy Mode
Dry Mode
(Cooling Model)
- Your unit shall have either Type A,Type B, Type C or Type D Remote Control
* Available in selected models. In other models, CHAOS is same as high speed.
-12-
Features of the Remote Control- Door Opened
Signal
transmitter
ON/OFF TIMER BUTTONS
1 Used
to set the time of starting and stopping
operation.
Signal
transmitter
TIME SETTING BUTTONS
2 Used
to adjust the time, (See page 21)
TIMER SET/CANCEL BUTTONS
3 Used
to set the timer when the desired time is
1
ON
OFF
SET
CANCEL
obtained and to cancel the Timer operation.
(See page 21)
4
5
2
3
JET COOL TEMP
6
PLASMA
FAN SPEED
7
8
A/SWING
POWER
SLEEP MODE AUTO BUTTON
4 Used
to set Sleep Mode Auto operation.
9
ON TIMER OFF
1
SLEEP
SET
3
4
FAN
TIMER
2
CANCEL
(See page 21)
5
ROOM
6
MODE PERSONAL MODE PLASMA
7
FAN MODE BUTTON
5 Used
to circulate the room air without cooling
RESET
8
9
or heating (turns indoor fan on/off).
(See page 22)
Signal
transmitter
ROOM TEMPERATURE
6 CHECKING BUTTON
Used to check the room temperature.
Signal
transmitter
7
4
CANCEL
1
5
2
7
3
ON
OFF
A/SWING
OL
JET CO
SET
6
8
POWER
TEMP
8
9
PERSONAL MODE
Used to run the unit in Personal Mode
(See page 19)
FAN SPEED
10
4
MODE
Flip-up door
(opened)
PLASMA (OPTIONAL)
Used to start or stop the plasma-purification
function. (See page 18)
1
5
2
7
SLEEP
ON TIMER OFF
FAN
ROOM
CANCEL
SET
9
3
6
TIMER
RESET BUTTON
Used prior to resetting time or after replacing
batteries.
PERSONAL MODE
8
9
2nd F Button (Type C or Type D
10
10 Remote Control)
Used prior to using modes printed in blue at
the bottom of buttons. (See page 20)
Flip-up door
(opened)
-13-
How to use the Operation Mode Selection button
Cooling Mode
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door on the remote control. To select Cooling
Mode, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
POWER
MODE
Cooling
3
JET COOL
FAN SPEED
TEMP
Fuzzy
Dry
Close the door on the remote control. Set the temperature
higher than the room temperature. The temperature can be
set within a range of 18°C~30°C in 1°C increments.
A/SWING
To raise the temperature
POWER
To lower the temperature
MODE
4
Set the fan speed again with the door
of the remote control still closed. You
can select the fan speed in four stepslow, medium, high or CHAOS*. Each
time the button is pressed, the fan
speed mode is shifted.
* Available in selected models. In other models, CHAOS is same as high speed.
-14-
FAN SPEED
Fuzzy Mode
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door on the remote control. To select Fuzzy
Mode, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
POWER
MODE
Cooling
JET COOL
FAN SPEED
TEMP
A/SWING
POWER
3
Fuzzy
Dry
The temperature and fan speed are automatically set by the
electronic controls based on the actual room temperature. If
you want to change the set temperature, close the door on
the remote control and press the Room Temperature Setting
buttons. The cooler or warmer you feel, the more times (up to
two times) you should press the button. The set temperature
will be changed automatically.
MODE
To raise the temperature
To lower the temperature
During Fuzzy Mode :
You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
-15-
Dry Mode
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door on the remote control. To select Dry Mode,
press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the arrow.
POWER
MODE
Cooling
JET COOL
FAN SPEED
TEMP
Fuzzy
Dry
A/SWING
POWER
MODE
During Dry Mode :
Unit will run at low fan speed with compressor 'ON'. When compressor is 'OFF', fan will be 'OFF'.
Set temperature cannot be changed.
-16-
Jet Cool Mode
JET COOL
TEMP
FAN SPEED
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Press the Jet Cool button to operate
the speed cooling mode and the unit
will operate in high fan speed
on cooling mode for 30 minutes.
3
To cancel the Jet Cool mode, press the Jet Cool button
again or the fan speed button or the room temperature
setting button or the Fan Mode Button.
POWER
JET COOL
A/SWING
POWER
TEMP
FAN
FAN SPEED
JET COOL
or
or
or
NOTE:
During the JET COOL function at any moment, the A/C starts to blow the cool air at
high speed for 30 minutes setting the room temp. automatically to 18°C. It is
especially used to cool the room temp. in the shortest time in a hot summer.
In order to return to the normal cooling mode from the JET COOL mode, you just press
either the operation mode selection button, Fan Speed button or temp. setting button
or the JET COOL button again.
-17-
PLASMA Purification Operation(Optional)
1
Press the Start/Stop button.
The unit will respond with a
beep.
2
Open the door on the remote control.
Press the PLASMA air purifying
operation ON/OFF button.
Operation will start when the button is
pressed and stop when the button is
pressed again.
3
JET COOL
FAN SPEED
TEMP
A/SWING
POWER
POWER
PLASMA
Set the fan speed again with door of the remote control
closed. You can select the fan speed in four steps-low,
FAN SPEED
medium, high or CHAOS*. Each time the
button is pressed, the fan speed mode
is shifted.
Air purifying operation (PLASMA) can be with cooling
or any other operations.
PLASMA Air Purifying Operation only
If you press only the PLASMA button, PLASMA
air purifying operates only.
Then, fan speed is low. You can select the fan
speed in four steps-low, medium, high or
CHAOS*.
Each time the button (
) is pressed, the fan
speed mode is shifted.
PLASMA
* Available in selected models. In other models, CHAOS is same as high speed.
-18-
Personal Mode (P1 / P2 / P3)
• Personal Mode is used to save the independent setting for the desired temperature, fan speed
and auto-swing for 3 different modes P1, P2, P3. Pressing the Personal Mode key on the remote
control will change the Personal Mode in the sequence P1 – P2 – P3 – P1 on the control panel.
Temperature setting key, fan speed key and auto-swing key on the control panel will be locked as
soon as Personal Mode is selected. Only buzzer will sound when these keys are pressed.
• Personal Mode will operate only when the unit is running in cool mode.
1
Press the Start/Stop button.
The unit will respond with a
beep.
2
Open the door on the Remote Control.
Press the Personal Mode operation button. PERSONAL MODE
The last personal mode P1 or P2 or P3,
which was running will be displayed on the
control panel. The unit will start to operate
as per the last saved settings of desired
temperature, fan speed, auto-swing for the
personal mode displayed.
3
Settings for desired temperature, fan speed, auto-swing can
be changed for each mode P1/P2/P3 separately after the
particular mode P1/P2/P3 has been selected using the
personal mode key.
4
After the settings have been changed or not changed for
desired temperature, fan speed, auto-swing in a particular
mode (P1/P2/ P3) the temperature setting key, fan speed key
auto-swing key will be locked within 20~25 sec of the last key
pressed during the process of changing the settings. Only
buzzer will sound when these keys are pressed. However, if
the personal mode key is pressed again the keys will be
unlocked.
5
When the unit is running in any of the personal modes P1/P2/
P3 and it is turned "OFF" and then turn "ON" using the control
panel, then the unit will start in cooling mode.
6
Personal Mode can be cancelled using the mode key, fan key
and the jet cool key on the remote controller and mode key on
the control panel.
PERSONAL MODE
JET COOL
TEMP
FAN SPEED
A/SWING
POWER
POWER
PERSONAL MODE
-19-
2nd F Operation
nd
2nd
F
CANCEL
ON
OFF
1
Press the Start/Stop button.
The unit will respond with
a beep.
2
Open the door of the remote control and press the 2nd
Function button to operate functions printed in blue at bottom
of buttons.
(Check the indication of 2nd function on remote control
display.)
SET
POWER
2ndF
ON
OFF
SET
ON TIMER OFF
SET
TIMER
A/SWING
OL
JET CO
POWER
TEMP
3
2nd function goes off in a short time automatically or when
the button is pressed again.
FAN SPEED
MODE
SLEEP
ON TIMER OFF
FAN
ROOM
CANCEL
SET
TIMER
PERSONAL MODE
-20-
Additional features
Sleep Mode
1
Press the Sleep Mode Auto button to set the SLEEP
time you want the unit to turn off automatically.
To cancel the Sleep Mode, press the sleep
Mode Auto button several times until the star
(
) disappears from the operation display.
2
The Timer is programmed in one-hour
increments by pressing the Sleep Mode Auto
button 1 to 7 times.
The sleep mode is available for 1 to 7 times. To
alter the time period in steps of 1 hour, press
the Sleep Mode Button while aiming at air
conditioner.
Note: 1. The Sleep Mode will be operated at
slow fan speed (cooling) or medium
fan speed (heat pump only) for quiet
sleeping.
2. Remote Control will display Fan Speed.
Set before sleep mode although Unit
Fan Speed changes.
3. When Sleep Mode is active, display on
the control panel will glow dull.
3
IN COOLING MODE : The temperature will
automatically rise by 1°C over the next 30
minutes and by 2°C in 1 hour for comfortable
sleeping.
Make sure the Sleep Mode Auto LED lights up.
Setting the Time
1
Time can be set only when you have pressed
the Reset button. If you have just replaced the
batteries, the Reset button should be pressed
to reset the time.
Press the Start/Stop button.
POWER
2
Press the Time Setting buttons until the
desired time is set.
TIMER
3
Press the Timer SET button.
SET
Note: Check the indicator
for A.M. and P.M.
Delay Start/Pre-Set Stop
1
Make sure the time is set correctly on the
remote control display.
2
Press the ON/OFF Timer
buttons to turn Timer on or off.
3
Press the Time Setting
buttons until the desired
time is set.
4
ON TIMER OFF
TIMER
Press the selected on/off setting by
pressing the Timer SET button while
aiming the remote control at the signal
receptor.
SET
To cancel the timer setting
Press the Timer Cancel button while
CANCEL
aiming remote control at the signal
receptor.
(The timer lamp on the air conditioner and
the display will go out.)
NOTE: Select one of the following four types of operation.
with the unit running
Delay OFF Timer
Delay ON Timer
Delay OFF and ON Timer Delay ON and OFF Timer
- In case of Auto Restart, ON/OFF Timer is automatically cancelled.
-21-
Fan Mode
Circulates the room air without cooling.
1
Press the Start/Stop button. the unit will respond with a beep.
2
Open the door on the remote control. Press the Fan button. Close the door on the
remote control. Now each time that you press the Indoor Fan Speed Selector, the fan speed is
shifted from low to CHAOS* and back to low again.
FAN
CHAOS Air
Fan speed is on low.
Fan speed is on medium.
Fan speed is on high.
* Available in selected models. In other models, CHAOS is same as high speed.
Auto restart
In case the power comes on again after a power failure, Auto Restarting Operation is the function to
operate procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
The compressor will start after 2.5~3 minutes.
-22-
670
765
660
430
POWER INPUT
BK(BL)
RD(BR)
THERMISTOR
GN(GN/YL)
C
MAIN P.W.B
ASSY
OR(BR)
H
S
COMP
R
C
CN-SYNC
RY-SYNC
RD
BK
BL
DISPLAY PCB ASSY
FFC
CN-DISP
RY-HI
YL
CAPACITOR
F
RY-MID
MOTOR
CN-TH1
RY-LOW
BK
RD
BL
OR(BR)
BR
BR
SYNC.
MOTOR
RY-COP
4 3
FUSE 250V T3.15A
WIRING DIAGRAM
HI03-00269B
Component location of main PCB assy.
Micom Model (Cooling model only)
0028
0029
0030
0027
0025
0021
0024
0026
0022
0034
0023
0033
0010
0020
0016
0017
0032
0019
0018
0015
0001
0009
0014
0008
0007
0006
0002
0011
0004
0005
A
6
03
0
0013
0003
B
36
0036C
00
0035
Download PDF