LG | TK-C0728H00.AWGSAEC | LG TK-C0908H00.AWGSAEC Owner’s Manual

website http://www.lgservice.com
e-mail http://lgservice.com/techsup.html
LG
LG Single Package Type
Air Conditioner
OWNER'S MANUAL
Prior to installation, this air-conditioning
unit must be submitted for approval by the
utility service which provides electricity
(EN 61000-2, 61000-3 Norm).
Model ˖
TK-C0728H00 TK-C0908H00
TK-C1208H00 TK-C1508H00
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
Single Package Type Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety Precautions ..............3
Write the model and serial numbers here:
Model #
Serial #
Operating Instructions........9
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Care and Maintenance ......15
Before You Call
for Service..........................17
■ Staple your receipt to this page in the event you need it
to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and
maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for
service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance
with the National Electric Code by qualified and
authorized personnel only.
2 Single Package Type Air Conditioner
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions
must be followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
WARNING
■ Installation
Do not use a defective or
underrated circuit breaker.
Use this appliance on a
dedicated circuit.
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
Always ground the product.
• There is risk of fire or electric
shock.
• Do not disassemble or repair the
product. There is risk of fire or
electric shock.
• There is risk of fire or electric
shock.
Install the panel and the
cover of control box
securely.
Always install a dedicated
circuit and breaker.
Use the correctly rated
breaker or fuse.
• There is risk of fire or electric
shock.
• Improper wiring or installation may
cause fire or electric shock.
• There is risk of fire or electric
shock.
Owner's Manual 3
Safety Precautions
Use the specified wires to
connect the unit.
• There is risk of fire or electric
shock.
For installation, always
contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric shock,
explosion, or injury.
Do not install, remove, or
re-install the unit by yourself
(customer).
• There is risk of fire, electric shock,
explosion, or injury.
Do not install the product on
a defective installation stand.
• It may cause injury, accident, or
damage to the product.
Be cautious when unpacking
and installing the product.
• Sharp edges could cause injury.
Be especially careful of the case
edges and the fins on the
condenser and evaporator.
Be sure the installation area
does not deteriorate with
age.
• If the base collapses, the air
conditioner could fall with it,
causing property damage, product
failure, and personal injury.
■ Operation
Do not let the air conditioner
run for a long time when the
humidity is very high and a
door or a window is left open.
• Moisture may condense and wet
or damage furniture.
Do not plug or unplug the
power supply plug during
operation.
• There is risk of fire or electric
shock.
Take care to ensure that
power cable could not be
pulled out or damaged
during operation.
• There is risk of fire or electric
shock.
Do not place anything on the
power cable.
• There is risk of fire or electric
shock.
Do not touch(operate) the
product with wet hands.
Do not place a heater or
other appliances near the
power cable.
• There is risk of fire or electrical
shock.
• There is risk of fire and electric
shock.
4 Single Package Type Air Conditioner
Safety Precautions
Do not allow water to run
into electric parts.
• It may cause There is risk of fire,
failure of the product, or electric
shock.
Do not store or use flammable
gas or combustibles near the
product.
• There is risk of fire or failure of
product.
Do not use the product in a
tightly closed space for a
long time.
• Oxygen deficiency could occur.
Gasolin
When flammable gas leaks,
turn off the gas and open a
window for ventilation before
turn the product on.
• Do not use the telephone or turn
switches on or off. There is risk of
explosion or fire.
Do not open the panel of the
product during operation. (Do
not touch the electrostatic filter,
if the unit is so equipped.)
• There is risk of physical injury,
electric shock, or product failure.
Ventilate the product from
time to time when operating
it together with a stove, etc.
• There is risk of fire or electric shock.
If strange sounds, or small or
smoke comes from product. Turn
the breaker off or disconnect the
power supply cable.
• There is risk of electric shock or
fire.
When the product is soaked
(flooded or submerged),
contact an Authorized
Service Center.
• There is risk of fire or electric
shock.
Turn the main power off
when cleaning or
maintaining the product.
• There is risk of electric shock.
Stop operation and close the window
in storm or hurricane. If possible,
remove the product from the window
before the hurricane arrives.
• There is risk of property damage,
failure of product, or electric shock.
Be cautious that water could
not enter the product.
• There is risk of fire, electric shock,
or product damage.
All batteries (whether installed or
attached) should not be exposed
to excess heat like sunlight or
similar source.
• They may burn or explode.
Owner's Manual 5
Safety Precautions
When the product is not be used for a long
time, disconnect the power supply plug or
turn off the breaker.
Take care to ensure that nobody could step
on or fall onto the unit.
• This could result in personal injury and product
damage.
• There is risk of product damage or failure, or
unintended operation.
CAUTION
■ Installation
Always check for gas
(refrigerant) pressure after
installation or repair of product.
• Low refrigerant levels may cause
failure of product.
Install the drain hose to
ensure that water is drained
away properly.
• A bad connection may cause
water leakage.
Keep level even when
installing the product.
• To avoid vibration or water
leakage.
90°
Do not install the product
where the noise or hot air
from the outdoor unit could
damage the neighborhoods.
• It may cause a problem for your
neighbors.
Don't use people to lift and
transport the product.
• Avoid personal injury.
Do not install the product
where it will be exposed to
sea wind (salt spray) directly.
• It may cause corrosion on the
product. Corrosion, particularly on
the condenser and evaporator fins,
could cause product malfunction or
inefficient operation.
Having perfect vacuum process in the factory, our units don't have drier but have filter in the
refrigerant circuit.
In case of recharging gas in the field,
"DRIER" must be installed on the liquid line which is connected from discharge part of
condenser to intake part of evaporator. Because the refrigerant circuit is capable of containing
water with imperfect vacuum.
6 Single Package Type Air Conditioner
Safety Precautions
■ Operation
Do not expose the skin directly to cool air for
long periods of time. (Don't sit in the draft.)
• This could harm to your health.
Do not use the product for special purposes,
such as preserving foods, works of art, etc. It
is a consumer air conditioner, not a precision
refrigeration system.
• There is risk of damage or loss of property.
Do not block the inlet or
outlet of air flow.
Use a soft cloth to clean. Do
not use harsh detergents,
solvents, etc.
• It may cause product failure.
• There is risk of fire, electric shock,
or damage to the plastic parts of
the product.
Do not touch the metal parts of
the product when removing the
air filter. They are very sharp!
• There is risk of personal injury.
x
Wa Thinner
Do not step on or put
anything on the product.
(outdoor units)
• There is risk of personal injury and
failure of product.
Always insert the filter securely.
Clean the filter every four weeks
or more often if necessary.
• A dirty filter reduces the efficiency
of the air conditioner and could
cause product malfunction or
damage.
Do not drink the water drained from the
product.
• It is not sanitary and could cause serious health
issues.
Do not insert hands or other objects
through the air inlet or outlet while
the product is operated.
• There are sharp and moving parts
that could cause personal injury.
Use a firm stool or ladder when cleaning or
maintaining the product.
• Be careful and avoid personal injury.
Owner's Manual 7
Prior to Operation
Prior to Operation
Preparing for operation
1. Contact an installation specialist for installation.
2. Plug in the power plug properly.
3. Use a dedicated circuit.
4. Do not use an extension cord.
5. Do not start/stop operation by plugging/unplugging the power cord.
6. If the cord/plug is damaged, replace it with only an authorized replacement part.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose
occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating
devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets,
plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal
edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to
possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high
speed during operation. There is a possibility of injury if the unit’s power is accidentally triggered on while
cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
8 Single Package Type Air Conditioner
Operating Instructions
Operating Instructions
Name and Function of Remote Controller
F
z
Fan Humidify Heat Auto
ON
OFF
Heat
Net
Day Button
3
Net Button(no use)
4
Timer Cancel Button
Used to set a day of the week.
Used to cancel the timer.
5
6
g
Swin
Humidify
Mode
Cancel
1 Timer Set Button
Used to set the timer when the unit desired time is
on/off.
2
fault
Group
Fan
Timer
Timer
Sleep Swing
Auto
C
Day
z
z
Cool
Set Temperature Button
Sleep
Fresh
Air
7 Fan Button
• Fan ON operation mode
• Fan AUTO operation mode
Used to turn the indoor fan motor to on/auto
operation mode by alternate pressing.
8 Swing direction Button(no use)
Used to control swing dirction.
9 Fresh Air Button(no use)
Used to supply fresh air to the room.
Used to set the temperature in the allowable
range.
10 Humidity Button(no use)
Used to increase or reduce the humidity.
On/Off Button
11 Sleep Mode Button
Used to run on sleep mode in order to
save energy.
Operation starts when this button is pressed, and
stops when the button is pressed again.
12 Mode Button
Cooling Operation mode;Fan operation;
Soft Dry operation
13 Timer Adjust Button
Used to adjust the timer setting
Owner's Manual 9
Operating Instructions
Wireless Remote Controller(Optional)
1
4
ON/OFF
2
FAN
TEMP
3
SLEEP
MODE
1 Power ON/OFF Button
• Operation will start when this button is pressed,
and stop when the button is pressed again.
2 Temperature Setting Button
3 Sleep Button
4 Fan Button
5 Mode Setting Button
10 Single Package Type Air Conditioner
5
Operating Instructions
Set the Current Time
1
Press the “
” button or “
”,the time is increased or reduced.
Timer
2
When press the Timer button“
” or“
” ˈthe symbol will glint.
ON
OFF
3
Please press“
” or “
” for 5 seconds,you can change the setting.
Note:
Please install battery,or timer will show “00:00” once power cut.(Please as follows pictures)
1
2
3
4
Owner's Manual 11
Operating Instructions
Timer Setting
1
If press the timer button,symbol will glint,the data will glint too.
ON
OFF
Day
Timer
Timer
Net
2
Fan
Mode
Cancel
g
Swin
Humidify
Sleep
Fresh
Air
If you don’t set timer,LCD will show:“- -” or will show the lasted setting time.
ON
OFF
3
4
Press “
” or “
” button to input ON/OFF time.If press these two buttons for long time,time will be
increase or reduce rapidly. Press “Cancel” button can cancel setting,LCD will show:“- -”
If don’t press any button,it will logout this timer setting program after 6 sencods.
12 Single Package Type Air Conditioner
Operating Instructions
Cancel Timer Setting
1
Press the “Cancel” button for 5 seconds,all timer setting will be canceled.
Day
Timer
Timer
Net
Fan
Mode
Cancel
g
Swin
Humidify
Sleep
Fresh
Air
Temperature Setting
1
You can change temperature from 16°C to 30 °C (60F to 85F).Press “
” and “
”
buttons for 5 seconds can interchange fahrenheit and centigrade.
2
When press any button,the lasted setting temperature will glint 4 times.If don’t press button again,
the system will resume to show the room temperature state.
Owner's Manual 13
Operating Instructions
Lock Setting
Press temperature button“
” and “
When in lock state, LCD will show “
” buttons for 3 seconds can lock on or off system.
Mode
” ,all button will invalidation except “
” button.
Press the same buttons for 3 seconds the lock will be cancelled.
Sensor Temperature Display
Press temperature button“
(-33°C~+78°C)
” and “
Mode
” buttons, time area will show sensor temperature.
ON
OFF
Temperature area will show “C 1”
F
Heat
z
ON
OFF
” or “
only for single package indoor pipe sensor).
14 Owner's Manual
z
z
Cool
Fan Humidify Heat Auto
Auto
C
Press temperature button “
fault
Group
Heat
” ,you can choose the sensor
fault
Group
Sleep Swing
Operating Instructions
Operating Instructions
Fan Operation and AUTO Function
1
2
Press the Fan button.
Every time you press the Fan button, it toggles As High-Middle-Low-Auto
(For Single Package High,middle,low is the same speed)
If Fan Auto function is On when outdoor unit is not working, Then the
indoor fan will not operate.
If Fan Auto function is Off when outdoor unit is not working,
Then the indoor fan operates at the adjusted speed.
Two Thermistor System
Open the rear cover of Remote Controller to set up the mode.
OFF
Selectable options Slide Switch3 are as follows.
ON
- OFF: Sensing the inlet air Temperature.
- ON: Sensing wired controller ambient temperature
To set up the mode, adjust the slide switch 3 to
desired mode position on installing.
Slide Switch3
Maunfactured in the position of the inlet air Temperature.
For Example :
Above shows the slide switch 3 ON ,
It means sensing the wired controller ambient temperature
Owner's Manua
15
Care and Maintenance
Care and Maintenance
CAUTION: Before performing any maintenance, turn off the main power to the system.
You can do some of the periodic maintenance for your unit yourself; this includes cleaning air filters, cleaning unit
cabinet, clearing the condenser coil, and conducting a general unit inspection on a regular basis.
WARNING: Before removing access panels to service unit, disconnect power supply.
Failure to disconnect power before attempting any servicing can result in severe injury
or death.
ANTI-BACTERIA-Air Filters
This product has anti-bacteria washable filters. It is very important to keep air filters clean in the central duct
system. Be sure to inspect them at least once each month when the system is in constant operation. (In new
buildings, check the filters every week for the first 4 weeks.)
Washable type filters can be cleaned by washing with a mild detergent and water. Ensure that the filters are
thoroughly dried before reinstalled them in the unit (or duct system).
Condenser coil
Unfiltered air circulates through the unit's condenser coil and can cause the coil's surface to become clogged with
dust, dirt, etc.. To clean the coil, vertically (i.e., along the fins) stroke the coil surface with a soft bristled brush.
Keep all vegetation away from the condenser coil area.
Maintenance Performed by serviceman-Cooling Season
To keep your unit operating safely and efficiently, the manufacturer recommends that a qualified serviceman
check the entire system at least once each year, or more frequently if conditions warrant. Your serviceman may
examine these areas of your unit:
1. Filters (for cleaning)
2. Motors and drive system components
3. Condenser coils (for cleaning)
4. Safety Controls (for mechanical cleaning)
5. Electrical components and wiring (for possible replacement or connection tightness)
6. Condensate drain (for cleaning)
7. Inspect the unit duct connections to ensure they are physically sound and sealed to the unit casing.
8. Inspect the unit mounting support to see that it is sound.
9. Inspect the unit to ensure there is no obvious deterioration.
Maintenance Performed by serviceman-Heating Season
Complete the unit inspections and service routines described below at the beginning of each heating season.
• Inspect the controller panel wiring to verify that all electrical connections are tight and that wire insulation is
intact.
16 Owner's Manual
Care and Maintenance
When the air conditioner is not going to be used for a long time
When air conditioner is not going to be used for a long time.
1. Operate the air conditioner on Air circulation mode for 2 to 3 hours.
• This will dry out the internal parts.
2. Turn off the circuit breaker.
CAUTION: Turn off the circuit breaker when the air conditioner is not going to be used
for a long time. Dirt may collect and may cause a fire.
When the air conditioner is to be used again.
1. Clean the air filter and re-install it in the indoor side.
On the fillter access panel at the left side of the unit, a “Filter access panel” label is attatched.
2. Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Operation Tips
Do not overcool the room.
This is not good for your health and
wastes electricity.
Keep blinds or curtains
closed.
Do not let direct sunshine enter the
room when the air conditioner is in
operation.
Clean the air filter regularly.
Blockages in the air filter reduce the
airflow and lower cooling and
dehumidifying effects.
CAUTION
Make sure that the doors
and windows are shut tight.
Avoid opening doors and windows
as much as possible to keep the
cool air in the room.
Ventilate the room
occasionally.
Since windows are kept closed, it is
a good idea to open them and
ventilate the room now and then.
Before removing access panels to
draw out air filters, disconnect
power supply.
Since the fan rotates at high speed, it
may cause a serious injury
Clean at least once every
month using a vacuum
cleaner or washing with a
neutral detergent in
lukewarm water.
After washing with water,
dry it well in the shade.
• Do not expose the air filter to
direct sunlight or heat from a
fire when drying it.
Single Package Type Air Conditioner
17
Before you call for service...
Before you call for service...
Check the following points before requesting repairs or service.... If the fault persists, please contact your dealer
or service center.
Case
Does not operate.
Explanation
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker been
tripped?
• Does the Remote controller display " " on the LCD?
This means that protective device has been tripped
please contact your dealer or service center.
The room has a peculiar odor.
• Check that this is not a damp smell exuded by the
walls, carpet, furniture, or cloth items in the room.
It seems that condensation is
leaking from the air conditioner.
• Condensation occurs when the airflow from the air
conditioner cools the warm air.
Air conditioner does not operate for
Fabout 3 minutes when restarted.
• Wait about three minutes and operation will begin.
Does not cool or heat effectively.
• This is the Protection device of the air conditioner.
• Is the air filter dirty? See air filter cleaning instructions.
• The room may have been very hot when the air
conditioner was first turned on. Allow time for it to cool
down.
• Has the setting temperature been set incorrectly?
• Are the unit's air inlet or outlet vents obstructed?
18
The air conditioner operation is
noisy.
• For a noise that sounds like water flowing.
-This is the sound of freon flowing inside the air
conditioner unit.
Remote controller display is faint,
or no display at all.
• Has the circuit breaker been tripped?
There's no air flow in cooling or
heating mode
• Have you selected Fan auto operation mode?
Owner's Manual
P/No:3828A99001L
Download PDF

advertising