LG | ARNH04GK2A2.ENWALEU | LG ARNH04GK2A2.ENWALEU Owner’s Manual

ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ΕΛΛΗΝΙΚΆ PORTUGUÊS
OWNER’S MANUAL
AIR
CONDITIONER
NEDERLANDS
Please read this manual carefully before operating your set and retain it for future
reference.
Hydro Kit (For Medium Temperature)
For more information, Refer to the CD or LG Web site (www.lg.com).
www.lg.com
P/NO : MFL67086801
MAGYAR
[Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared
Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands
[Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsangu, Changwon-si, Gyeongsangnam-do, KOREA
POLSKI
Original instruction
Hydro Kit Owner’s Manual
TABLE OF CONTENTS
Safety Precautions .............................3
Product Introduction ..........................8
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Owner's Instruction ..........................10
Serial #
Using Thermostat .............................23
You can find them on a label on the side of each
unit.
Maintenance and Service.................26
Installer's Name
Purchased Date
n Staple your receipt to this page in the event you
need it to prove date of purchase or for warranty
issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use and
maintain your Hydro Kit properly. Just a little preventive
care on your part can save you a great deal of time and
money over the life of your product.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call for
service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• Hydro Kit is not intended for use by young children or
invalids without supervision.
• Young children should be supervised to ensure that
they do not play with Hydro Kit.
• When the power cable is to be replaced, replacement
work must be performed by authorized personnel
only using only genuine replacement parts.
• Installation work must be performed in accordance
with the National Electric Code by qualified and
authorized personnel only.
2 Hydro Kit
Safety Precaution
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
n Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage.
WARNING
Always ground the
product.
Do not use a defective
or underrated circuit
breaker. Use this
appliance on a dedicated circuit.
Do not use a multi
outlet. Always use
this appliance on a
dedicated circuit and
breaker.
• There is a risk of electric shock.
• There is risk of fire or
electric shock.
• It can cause electric
shock or fire.
For electrical work,
contact the dealer, seller, a qualified electrician, or an Authorized
Service Center. Do not
disassemble or repair
the product by yourself.
Always ground the
product as per the
wiring diagram. Do not
connect the ground
wire to gas or water
pipes lightening rod or
telephone ground wire.
Install the panel and
the cover of control
box securely.
• There is risk of fire or
electric shock.
• There is risk of fire or
electric shock.
• There is risk of fire or
electric shock due to
dust , water etc.
Use the correctly
rated breaker or fuse.
Do not modify or extend
the power cable. If the
power cable or cord has
scratches or skin peeled
off or deteriorated then it
must be replaced.
For installation,
removal or reinstallation , always contact
the dealer or an
Authorized Service
Center.
• There is risk of fire or
electric shock.
• There is risk of fire or
electric shock.
• There is risk of fire,
electric shock, explosion, or injury.
Hydro Kit Owner’s Manual 3
ENGLISH
Safety Precautions
Safety Precaution
Do not install the product on a defective
installation stand. Be
sure that the installation area does not
deteriorate with age.
Never install the outdoor unit on a moving
base or a place from
where it can fall down.
• It may cause product to • The falling outdoor unit
can cause damage or
fall.
injury or even death of
a person.
Be sure to check the
refrigerant to be used.
Please read the label
on the product.
Don't use a power
cord, a plug or a
loose socket which is
damaged.
When the product is
soaked (flooded or submerged) in water, contact
an Authorized Service
Center for repair before
using it again.
• There is risk of fire or
electric shock.
Do not touch , operate, or repair the product with wet hands.
• Incorrect refrigerant can • Otherwise it may cause • There is risk of electric
shock or fire.
a fire or electrical
prevent the normal
shock.
operation of the unit.
Do not store or use or
even allow flammable
gas or combustibles
near the product.
Do not place a heater
or other heating appliances near the power
cable.
Do not allow water to
run into electric parts.
Install the unit away
from water sources.
• There is risk of fire and
electric shock.
• There is risk of fire, fail- • There is risk of fire.
ure of the product, or
electric shock.
Indoor/outdoor wiring
connections must be
secured tightly and the
cable should be routed
properly so that there is
no force pulling the
cable from the connection terminals.
Safely dispose off the
packing materials. Like
screws, nails, batteries,
broken things etc after
installation or service
and then tear away and
throw away the plastic
packaging bags.
Make sure to check
that the power device
is not dirty, loose or
broken and then Turn
on the power.
• Improper or loose connections can cause
heat generation or fire.
• Children may play with
them and cause injury.
• Dirty, loose or broken
power device can cause
electric shock or fire.
4 Hydro Kit
Safety Precaution
When installing the
unit, use the installation kit provided with
the product.
Be sure to use only
those parts which are
listed in the service
parts list. Never
attempt to modify the
equipment.
• An charged capacitor
can cause electrical
shock.
• Otherwise the unit may
fall and cause severe
injury.
• The use of inappropriate
parts can cause an electrical shock, excessive
heat generation or fire.
Do not use the product in a tightly closed
space for a long time.
Perform ventilation
regularly.
Do not open the front
cover or grille of the
product during operation. (Do not touch the
electrostatic filter, if the
unit is so equipped.)
If strange sounds,
smell or smoke comes
from product, immediately turn the breaker
off or disconnect the
power supply cable.
• Oxygen deficiency
could occur and hence
harm your health.
• There is risk of physical • There is risk of electric
injury, electric shock, or shock or fire.
product failure.
Ventilate the product
room from time to time
when operating it
together with a stove,
or heating element etc.
Turn the main power
off when cleaning or
repairing the product.
Take care to ensure
that nobody especially kids could step on
or fall onto the outdoor unit.
• Oxygen deficiency can
occur and hence harm
your health.
• There is risk of electric
shock.
• This could result in personal injury and product
damage.
Take care to ensure
that power cable
could not be pulled
out or damaged during operation.
Do not place ANYTHING on the power
cable.
When flammable gas
leaks, turn off the gas
and open a window for
ventilation before turning the product on.
• There is risk of fire or
electric shock.
• There is risk of fire or
electric shock.
• Do not use the telephone or turn switches
on or off. There is risk
of explosion or fire.
Hydro Kit Owner’s Manual 5
ENGLISH
In outdoor unit the
step-up capacitor supplies high voltage electricity to the electrical
components. Be sure to
discharge the capacitor
completely before conducting the repair work.
Safety Precaution
CAUTION
Two or more people
must lift and transport
the product.
Do not install the product where it will be
exposed to sea wind
(salt spray) directly.
Keep level even when
installing the product.
• Avoid personal injury.
• It may cause corrosion
on the product.
• To avoid vibration or
noise.
Do not install the product
where the noise or hot air
from the outdoor unit
could damage or disturb
the neighborhoods.
Always check for gas
(refrigerant) leakage
after installation or
repair of product.
Do not use the product
for special purposes,
such as preserving
foods, It is not a precision
refrigeration system.
• It may cause a problem • Low refrigerant levels
may cause failure of
for your neighbors and
product.
hence dispute.
• There is risk of damage
or loss of property.
Do not block the inlet
or outlet of air flow.
Use a soft cloth to
clean. Do not use harsh
detergents, solvents or
splashing water etc .
Do not step on or put
anyting on the product. (outdoor units)
• It may cause product
failure.
• There is risk of fire,
electric shock, or damage to the plastic parts
of the product.
• There is risk of personal
injury and failure of
product.
Do not insert hands or
other objects through
the air inlet or outlet
while the product is
operating.
Be cautious when
unpacking and
installing the product.
If the refrigerant gas
leaks during the
repair, do not touch
the leakaing refrigerant gas.
• Sharp edges could
• There are sharp and
cause injury.
moving parts that could
cause personal injury.
6 Hydro Kit
• The refrigernat gas can
cause frostbite (cold
burn)
Safety Precaution
If the refrigerant gas
leaks during the installation, ventilate the
area immediately.
• The condensed water
inside can spill.
• Otherwise it can be
harmfull for your health.
Dismantling the unit,
treatment of the refrigerant oil and eventual
parts should be done
in accordance with
local and national
standards.
Do not expose your skin or kids or
plants to the cool or hot air draft.
Use a firm stool or ladder when
cleaning, maintaining or repairing
the product at an height.
• This could harm to your health.
• Be careful and avoid personal injury.
Hydro Kit Owner’s Manual 7
ENGLISH
Do not tilt the unit
when removing or
uninstalling it.
Product Introduction
Product Introduction
Typical Installation Scene
Water Out
Gas side
Liquid side
Water In
Drain
CAUTION
Use of power supply separate power for the indoor unit. (Do not connect and use from the
power terminal of the outdoor unit.)
8 Hydro Kit
Product Introduction
ENGLISH
Remote Controller
‫ڸ‬
‫ۀ‬
‫ڿ‬
‫ھ‬
‫ڽ‬
‫ہ‬
‫ۂ‬
‫ڹ‬
‫ں‬
‫ڻ‬
ZDWHU
KHDWLQJ
WHPS
RSHU
PRGH
‫ڼ‬
‫ۃ‬
‫ۄ‬
No
1
2
3
4
5
6
7
8
9
10
11
12
13
Name
Display
Change Temperature Button
Water Heating Enable / Disable Button
Power Button
Operation Mode Selection Button
Silent Mode On / Off Button
Temperature Setting Mode Button
Temperature View Mode Button
Function Setting Button
Programming Button
Direction Button (Up, Down, Left, Right)
Set / Clear button
ESC Button
h Grey painted functions may not be operated and displayed.
Hydro Kit Owner’s Manual 9
Owner's instruction
Owner's Instruction
Monitoring Information
WATER PUMP
This icon indicates that the water pump is active.
AUXILIARY SOLAR THERMAL PUMP
This icon indicates that auxiliary solar thermal pump is active.
NOTE : As installation of auxiliary solar thermal pump is not compulsory but recommendatory according to field condition, this icon can be seen although no auxiliary solar thermal
pump is installed.
DEFROSTING
This icon indicates that the defrost mode is active.
In space heating operation or sanitary water tank heating operation, freezing of the outdoor heat exchanger may be occur due to low outdoor temperature and humidity. If this
risk occurs, the product goes into defrost operation. It reverses the cycle and takes heat
from the indoor system to prevent freezing of the outdoor system. This mode is automatically operating.
MAINTAIN LOWEST TEMPERATURE
The purpose of this mode is maintaining the temperature to prevent damage by freezing of
water pipe.
OUTDOOR
This icon indicates that the outdoor unit is active.
CHILD LOCK
NO FUNCTION
10 Hydro Kit
Owner's instruction
This icon indicates that the product is controlled by the central controller.
THERMOSTAT
This icon indicates connection with thermostat.
SLIGHT TROUBLE
This icon indicates that slight trouble occurs.
HEAVY TROUBLE
This icon indicates that heavy trouble occurs.
Hydro Kit Owner’s Manual 11
ENGLISH
CENTRAL CONTROLLER
Owner's instruction
Mode Change
Turn on the product and select operation mode.
1
Press Power Button to turn on the product.
2
Press OPER MODE Button to select each operation mode.
Cooling operation
Heating operation
Weather dependent
operation
Operation Mode
• Cooling Operation - The product yields cool water to use in under floor cooling or FCU cooling.
• Heating Operation - The product yields hot water to use in under floor heating or FCU heating.
• Weather dependent Heating Operation - In this mode, heating setpoint is automatically determined
by pre-defined temperature profile.
Selecting Target Temperature
1
Press SET TEMP Button to select each operation mode.
Room temperature
2
Water temperature
Sanitary Water Tank
temperature
Adjust desired temperature by pressing Change Temperature buttons on each mode.
To raise the Temperature
To lower the Temperature
j Note
: Increase 1°C or 2°F per one time pressing
: Decrease 1°C or 2°F per one time pressing
• We can change the temperature range of each mode on installation setting mode. Please refer
to Function Code 11 to 15.
• Room Temperature setting is available when Remote Room Air Sensor (sold separately) is
installed. Please refer to Function Code 03.
• Sanitary Water Tank temperature setting is available when Sanitary Water Tank is installed.
12 Hydro Kit
Owner's instruction
This mode is only applied to heating.
In order to save energy and to give highest comfort, setting temperature will follow outside temperature. If outdoor temperature decreases, heating capacity for the house will increase automatically in
order to keep same room temperature. All parameters will be set by installer during start-up procedure and will be adapted to the site characteristic.
1
Press OPER MODE Button to select Weather-dependent operation mode.
2
Adjust the desired temperature level by pressing Change Temperature buttons.
: Weather Dependent
operation icon
Ex) Decreasing temperature profile by 3°C
(based on room air temperature)
<Temperature adjust step (unit : °C)>
-5, -4, -3, -2, -1, 0, 1, 2, 3, 4, 5
Hot
Cold
View Temperature
1
: View Room Temperature
Press repeatedly View
Temperature Button to select
each Temperature.
(Whenever press View
Temperature button, the room
temperature will be displayed
during 5 seconds.)
Temperature
Air
Water
: View Inlet Temperature
: View Outlet Temperature
: View Sanitary Water Temperature
(ONLY displayed when sanitary
water heating mode)
: View Solar Thermal Temperature
(ONLY displayed when sanitary
water heating mode)
Temperature Range
Displayed as
below 11°C(51°F)
Lo
11°C(51°F) ~ 39°C(102°F)
actual temperature
above 39°C(102°F)
Hi
below 0°C(32°F) [*below 40°C(104°F) ]
Lo
0°C(32°F) ~ 92°C(197°F) [*40°C(104°F) ~ 120°C(248°F) ]
actual temperature
above 92°C(197°F) [*above 120°C(248°F) ]
Hi
[* : Solar Thermal Temperature]
Hydro Kit Owner’s Manual 13
ENGLISH
Weather-dependent Operation
Owner's instruction
Child Lock
This function is to prevent children or other people from using controller.
1
Press Function Setting Button to enter
user setting mode. (The segment will be flashed)
2
Press set/clear button to finish the selection.
The segment will disappear.
3
During Child Lock,
icon and 'CL' will be displayed during 3 seconds whenever entering any
kind of buttons except for view temperature button
and setting/clear button.
4
To release this setting, press function Setting
button until
icon flashes and then enter setting/clear button.
14 Hydro Kit
Owner's instruction
When the error is occurs on indoor unit, the error code will be displayed on remote controller.
Slight trouble
A problem is found inside the indoor unit. In most case, this trouble is concerned with
sensor problems. In this case, Hydro Kit can operate in an emergency mode
(only Heating operation).
<Display>
Heavy trouble
A problem is found inside the outdoor unit.
<Display>
Critical error
On critical error, the product will stop unconditionally.
At this time, CH' and error code No. keep display by turns.
<Display>
Hydro Kit Owner’s Manual 15
ENGLISH
Error code display
Owner's instruction
Setting Current Time
You can set current time.
Keep pressing programming button twice successively to enter setting
current time mode.
1
2
Press left, right button to adjust the current day.
3
Press down button to move to AM/PM
part and adjust it. (The AM/PM segment
will be flashed)
4
Press right button to move to "Hour"
part. (the "Hour" segment will be
flashed)
5
Press up, down button to adjust the
Hour.
6
Press right button to move to "Minute"
part. (the "Minute" segment will be
flashed)
7
Press up, down button to adjust the
Minute.
8
If you finish the setting, press set/clear
button.
9
Press exit button to exit or system will automatically release without any
input 25 seconds.
16 Hydro Kit
Owner's instruction
You can easily turn-on reservation.(ONLY enable when unit is stand-by.)
1
Press programming button to enter the
Programming mode. (the segment will be
flashed)
2
Press up, down button to adjust the reservation time.
3
If you finish the setting, press setting/cancel button to complete programming
4
Press exit button to exit or system will automatically release without any
input after 25 seconds.
Programming : Setting Sleep Reservation
You can easily turn-off(sleep) reservation.(ONLY enable when unit is operating.)
1
Press programming button to enter the
Programming mode. Press Programming
button repeatedly to select [sleep reservation]. (the segment flashing)
2
Press up, down button to adjust the reservation time.
3
If you finish the setting, press setting/cancel button to complete programming.
4
Press exit button to exit or system will automatically release without any
input after 25 seconds.
Hydro Kit Owner’s Manual 17
ENGLISH
Programming : Setting Simple Reservation
Owner's instruction
Programming : Setting ON Reservation
This function is able to turn-on after a setting time.
1
Press programming button to enter the
Programming mode. Press Programming
button repeatedly to select [on reservation].
(the segment flashing)
2
Press up, down button to adjust AM/PM.
3
Press right button to move to "Hour"
part. (the "Hour" segment will be
flashed)
4
Press up, down button to adjust the
Hour.
5
Press right button to move "Minute" part.
(the "Minute" segment will be flashed)
6
Press up, down button to adjust the
Minute.
7
If you finish the setting, press setting/cancel button to complete
programming.
8
Press exit button to exit or system will automatically release
without any input after 25 seconds.
18 Hydro Kit
Owner's instruction
This function is able to turn-off after a setting time.
1
Press programming button to enter the
Programming mode. Press Programming
button repeatedly to select [off reservation].
(the segment flashing)
2
Press up, down button to adjust AM/PM.
3
Press right button to move to "Hour"
part. (the "Hour" segment will be
flashed)
4
Press up, down button to adjust the
Hour.
5
Press right button to move to "Minute"
part. (the "Minute" segment will be
flashed)
6
Press up, down button to adjust the
Minute.
7
If you finish the setting, press setting/cancel button to complete
programming.
8
Press exit button to exit or system will automatically release
without any input after 25 seconds.
Hydro Kit Owner’s Manual 19
ENGLISH
Programming : Setting OFF Reservation
Owner's instruction
Programming : Weekly Reservation
The weekly reservation is active after setting current time.
1
Press programming button to enter the
Programming mode. Press Programming
button repeatedly to select [Weekly reservation]. (the segment flashing)
2
Press left, right button to adjust the current day.
3
Press up, down button to adjust the
action number.
4
Press right button to move to "Hour"
part on ON Time section.
(The "Hour" segment will be flashed)
Start Time Section
5
Press up, down button to adjust the
Hour on Start Time section.
6
Press right button to move to "Minute"
part on Start Time section.
(The "Minute" segment will be flashed)
7
Press up, down button to adjust the
Minute on Start Time section.
8
Press right button to move to "Hour" part
on OFF Time section.
(The "Hour" segment will be flashed)
Off Time Section
20 Hydro Kit
Owner's instruction
ENGLISH
9
Please refer to the process from No.5 to
No.7 for setting OFF Time. It is the same
method.
10
If you finish the setting, press setting/cancel button to complete programming. The under bar segment
will be created, when finished.
11
Please refer to the process from
No.2 to No.10 for setting other day
weekly program. It is the same
method.
12
Press exit button to exit or system will automatically
release without any input after 25 seconds.
<Note>
Description of weekly reservation
<Start Time Section>
Action
Start Time
From
<Start Time Section>
<Off Time Section>
To
Off Time
<Off Time Section>
h Two actions per weekday can be programmed, in total 14 actions
Hydro Kit Owner’s Manual 21
Owner's instruction
Programming : Holiday Reservation
This function is to automatically stop the machine working on some days.
1
Press programming button to enter the
Programming mode. Press Programming
button repeatedly to select [Holiday reservation]. (the segment flashing)
2
Press left, right button to adjust the holiday.
3
When you press set/clear button after
finishing the selection, the day selected
will disappear.
4
Press exit button to exit or system will automatically release without any input
after 25 seconds.
22 Hydro Kit
Using Thermostat
The term "thermostat", which is widely used in this chapter, is a kind of 3rd party accessory.
LG Electronics does not supply thermostat. but it can be supplied by 3rd party manufacturers.
Room thermostat can be used for easy and convenience control. To utilize thermostat more efficiently and correctly, this chapter presents information about using thermostat.
CAUTION
1. Some electro-mechanical type thermostat has internal delay time to protect compressor.
In that case, mode change can takes time more than user's expectation. Please read thermostat manual carefully if the product does not response quickly.
2. Setting temperature range by thermostat can be different with that of the product. The heating or
cooling set temperature should be chosen within the setting temperature range of the product.
How to use Thermostat
To find how to turn on and off, how to set target temperature, how to change operating mode, etc,
please refer to thermostat operating manual provided by thermostat manufacturer.
Operating Thermostat with Remote Controller
• Following features are permitted when thermostat is installed :
•
SET TEMP button
•
VIEW TEMP button
•
Temperature adjust button (*)
•
Sanitary water heating Enable / Disable
(*) : The product does not turn on / off according to the setting temperature at the remote controller. It turns on / off according to the thermostat signal.
• Following features are NOT permitted when thermostat is installed :
•
Operating mode (cooling/ heating/ weather-dependent) selection
•
Time scheduling
•
Operation On / Off
Hydro Kit Owner’s Manual 23
ENGLISH
Using Thermostat
Using Thermostat
Emergency Operation
• Definition of terms
- Trouble : a problem which can stop system operation, and can be resumed temporally under limited operation without certificated professional's assist.
- Error : problem which can stop system operation, and can be resumed ONLY after certificated
professional's check.
- Emergency mode : temporary heating operation while system met Trouble.
• Objective of introducing 'Trouble'
- Not like airconditioning product, hydro kit is generally operated in whole winter season without
any system stopping.
- If system found some problem, which is not critical to system operating for yielding heating energy, the system can temporarily continue in emergency mode operation with end user's decision.
• Classified Trouble
- Trouble is classified into two levels according to the seriousness of the problem : Slight Trouble
and Heavy trouble
- Slight Trouble : a problem is found inside the indoor unit. In most case, this trouble is concerned
with sensor problems. The outdoor unit is operating under emergency mode operation condition
which is configured by DIP switch No. 4 of the indoor unit PCB.
- Heavy trouble : a problem is found inside the outdoor unit.
- Option Trouble : a problem is found for option operation such as water tank heating. In this trouble, the troubled option is assumed as if It does not cause in the Product.
• Emergency operation level
- When system met trouble, it stops operation and waits for user’s decision : Calling service center
or starting emergency operation.
- To start emergency operation, user simply pushes ON / OFF button once more.
- Two different levels are prepared for emergency operation : High temperature cycle and low temperature cycle.
- In emergency operation mode, user can not adjust target temperature.
DIP
Switch
Target
Leaving Water
Temperature
Target
Room Air
Temperature
Target
Sanitary Water
Temperature
High temperature cycle
OFF
50℃(122℉)
24℃(75℉)
50℃(122℉)
Low temperature cycle
ON
30℃(86℉)
19℃(66℉)
50℃(122℉)
24 Hydro Kit
Using Thermostat
-
Operation On/Off
-
VIEW TEMP button(*)
-
Temperature adjust button (*)
-
Sanitary water heating Enable / Disable
(*) : Temperature measured by failed sensor is displayed as ‘- -’.
The product does not turn on / off according to the setting temperature at the remote controller.
It turns on / off according to the thermostat signal.
• Following features are NOT permitted in emergency operation :
-
Operating mode (cooling/ heating/ weather-dependent) selection
-
Time scheduling
-
SET TEMP button
• Duplicated trouble : Option trouble with Slight or Heavy trouble
- If option trouble occurs with slight (or heavy) trouble at the same time, the system puts higher priority to slight (or heavy) trouble and operates as if slight (or heavy) trouble is occurred.
- Therefore, sometimes sanitary water heating can be impossible in emergency operation mode.
When sanitary water is not warming up while emergency operation, please check if sanitary water
sensor and related wiring are all Ok.
• Emergency operation is not automatically restarted after main electricity power is reset.
- In normal condition, the product operating information is restored and automatically restarted
after main electricity power is reset.
- But in emergency operation, automatic re-start is prohibited to protect the product.
- Therefore, user must restart the product after power reset when emergency operation has been
running.
Hydro Kit Owner’s Manual 25
ENGLISH
• Following features are permitted in emergency operation :
Maintenance and Service
Maintenance and Service
Maintenance activities
In order to ensure optimal availability of the unit, a number of checks and inspections on the unit and
the field wiring have to be carried out at regular intervals, preferably yearly. This maintenance should
be carried out by your local agreed technician.
When the unit is not going....
CAUTION
• If the product is not used for long time, we strongly recommend
NOT TO SWITCH OFF THE POWER SUPPLY to the product.
• If power is not supplied, some special product-protecting
actions
(such as water pump anti-locking) will not performed.
Call the service immediately in the following situations
1. Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and turn the
breaker off. Never try to repair by yourself or restart the system in such cases.
2. Main power cord is too hot or damaged.
3. Error code is generated by self diagnosis.
4. Water leaks from indoor unit.
5. Any switch, breaker (safety, earth) or fuse fails to work properly
User must carry routine checkup & cleaning to avoid unit’s poor performance.
In case of special situation, the job must be carried out by the only service person.
26 Hydro Kit
Maintenance and Service
n Do not disconnect the power supply of Hydro Kit during the operation.
Stop the Hydro Kit followed by outdoor unit and then only remove the power supply.
WARNING
If you remove the power supply of the Hydro Kit in the mid of operation, it will leads to damage of
the product by freezing and bursting of Plate type Heat Exchanger.
n Do not remove the power supply even at the occurrence of “CH14” Error.
As the error is due to the shortage of water flow, please eliminate any sludge and scales inside the
water tubes to ensure free water pumping, remove foreign particles(dust, sand, trash, rusted
pieces) from the water tubes along with cleaning the strainer.
After cleaning the strainer, to remove the error message (not displayed), turn off the outdoor unit
followed by Hydro Kit and then disconnect power supply of Hydro Kit. And then connect power
supply and restart the unit for the normal operation.
WARNING
The service will be charged if the system failure is due to strainer blockage.
Strainer cleaning period: Once in every 3 months and whenever CH14 error occurs.
n If the system stopped and displaying any error message(CH ???) please follow below procedure.
Do not remove the power supply of the Hydro Kit. Contact L.G service centre.
n Do not change the water pipes randomly. When changing the water pipes there is a possibility of
foreign material entry and bubble formation as well. This leads to freezing of Plate type heat
exchanger of Hydro Kit.
When it is essential to change the water pipes, proceed only after separating the pipes from Hydro
Kit. The inner side of the new pipes must be washed thoroughly to remove the foreign materials
and then connect the pipes with the Hydro Kit.
Hydro Kit Owner’s Manual 27
ENGLISH
Operational instructions
Maintenance and Service
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist, please
contact your dealer.
Case
Hydro Kit does not operate.
Explanation
• Have you made a mistake in timer operation?
• Has the fuse blown or has the circuit breaker been tripped?
The room has a peculiar odor.
Hydro Kit does not operate for
about 3 minutes when restart.
Does not cool or heat effectively.
• Check that this is not a damp smell exuded by the walls, carpet,
furniture or cloth items in the room.
• This is the protector of the mechanism.
• Wait about three minutes and operation will begin.
• The room may have been very hot when the Hydro Kit was first
turned on. Allow time for it to cool down.
• Has the setting temperature been set incorrectly?
The unit operation is noisy.
• Refrigerant flow sound
- While the system is being started or stopping, sound from the
refrigerant flow may be heard.
• Sound for the indoor unit heat exchanger
- During the cooling operation, a sound may be heard from the
indoor unit heat exchanger due to water freezing or melting.
• Water noise
- During starting or stopping of the unit, noise can appear in
water piping
• During defrost
- Noise can appear in unit due to defrosting of water.
Steam is raised in outdoor unit.
• Steam from outdoor heat exchanger
- During defrosting operation, ice on the outdoor heat exchanger
is melted, resulting in making steam.
Remote controller display is faint,
or no display at all.
• Has the circuit breaker been tripped?
28 Hydro Kit
Download PDF

advertising