LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 1
Dynamic Controller
Owner’s Manual
MODEL : LCC-K1000
Before installing and using the product, please read this owner's
manual carefully and retain for future reference.
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 2
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION: TO REDUCE THE RISK
OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE
PERSONNEL.
This lightning flash with arrowhead symbol
within an equilateral triangle is intended to
alert the user to the presence of uninsulated dangerous voltage within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
WARNING: Do not install this equipment in a confined space such as a bookcase or similar unit.
CAUTION: The apparatus should not be exposed to
water (dripping or splashing) and no objects filled
with liquids, such as vases, should be placed on the
apparatus.
FCC WARNING: This equipment may generate or
use radio frequency energy. Changes or modifications to this equipment may cause harmful interference unless the modifications are expressly
approved in the instruction manual. The user could
lose the authority to operate this equipment if an
unauthorized change or modification is made.
This product is manufactured to comply
with the radio interference requirements of
EEC DIRECTIVE 89/336/EEC, 93/68/EEC
and 73/23/EEC.
2
Regulatory Notices For U.S.A
This equipment has been tested and found to comply
with the limits for a Class A digital device,pursuant to
Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment.
This equipment generates,uses,and can radiate radio
frequency energy and,if not installed and used in
accordance with the instruction manual,may cause
harmful interference to radio communications.Operation
of this equipment in a residential area is likely to cause
harmful interference in which case the user will be
required to correct the interference at his own expense.
• A suitable conduit entries, knock-outs or glands shall
be provided in the cable entries of this product in the
end user.
•
Caution: Danger of explosion if battery is incorrectly
replaced.Replaced only with the same or equivalent
type recommended by the manufacturer. Dispose of
used batteries according to the manufacturer ’s
instructions.
•
Holes in metal, through which insulated wires
pass,shall have smooth well rounded surfaces or
shall be provided with brushings.
WARNING: This is a class A product. In a domestic
environment this product may cause radio interference
in which case the user may be required to take adequate measures.
WARNING: Wiring methods shall be in accordance
with the National Electric Code, ANSI/NFPA 70.
SERIAL NUMBER:
You can find the serial number on the back of the
unit. This number is unique to this unit and not available to others. You should record requested information here and retain this guide as a permanent record
of your purchase.
Model No. ______________________________
Serial No. ______________________________
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 3
IMPORTANT SAFETY INSTRUCTIONS
CAUTION:
PLEASE READ AND OBSERVE ALL WARNINGS AND INSTRUCTIONS IN THIS OWNER’S MANUAL. AND
THOSE MARKED ON THE PRODUCT. RETAIN THIS BOOKLET FOR FUTURE REFERENCE.
This product has been designed and manufactured to assure personal safety. Improper use can result in electric shock or
fire hazard. The safeguards incorporated in this product will protect you if you observe the following procedures for installation, use, and servicing.
This product does not contain any parts that can be repaired by the user.
DO NOT REMOVE THE CABINET COVER, OR YOU MAY BE EXPOSED TO DANGEROUS VOLTAGE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL ONLY.
1. Read these instructions. - All these safety and operating
instructions should be read before the product is operated.
10. Protect the power cord from being walked on or
pinched particularly at plugs, convenience receptacles, and the point where they exit from the product.
2. Keep these instructions. - The safety, operating and use
instructions should be retained for future reference.
11. Only use attachments/accessories specified by the
manufacturer.
3. Heed all warnings. - All warnings on the product and in
the operating instructions should be adhered to.
4. Follow all instructions. - All operating and use instructions should be followed.
5. Do not use this product near water. – For example:
near a bath tub, wash bowl, kitchen sink, laundry tub, in a
wet basement; or near a swimming pool; and other areas
located near water.
6. Clean only with dry cloth. – Unplug this product from the
wall outlet before cleaning. Do not use liquid cleaners.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. - Slots and
openings in the cabinet are provided for ventilation and to
ensure reliable operation of the product and to protect it
from over- heating. The openings should never be
blocked by placing the product on a bed, sofa, rug or other
similar surface. This product should not be placed in a
built-in installation such as a bookcase or rack unless
proper ventilation is provided or the manufacturer’s
instructions have been adhered to.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
12. Use only with the cart, stand, tripod, bracket, or
table specified by the manufacturer, or sold with
apparatus. When a cart is used, use caution when
moving the cart/product combination to avoid injury
from tip-over.
13. Unplug this product during lightning storms or
when unused for long periods of time.
14. Refer all servicing to qualified service personnel.
Servicing is required when the product has been
damaged in any way, such as power-supply cord or
plug is damaged, liquid has been spilled or objects
have fallen into the product, the product has been
exposed to rain or moisture, does not operate normally, or has been dropped.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug
has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If
the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
3
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 4
Introduction
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
About Dynamic Controller . . . . . . . . . . . . . . . . .5
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Identification of the Controller . . . . . . . . . . . . .6-7
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
RS-485 Connection . . . . . . . . . . . . . . . . . . . . . . . .8
Setup Menu . . . . . . . . . . . . . . . . . . . . . . . . . . .9-21
Setup Menu Overview . . . . . . . . . . . . . . . . . . . . . .9
Key Functions on the Set Up . . . . . . . . . . . . . . . .10
Operation Start (Login) . . . . . . . . . . . . . . . . . . . .10
Communication Settings . . . . . . . . . . . . . . . . . . .11
List of the communication settings . . . . . . . . .11
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Protocol Setting . . . . . . . . . . . . . . . . . . . . . . .11
Communication Speed (Baud Rate) Setting . .11
Parity bit / Data Bits Setting / Stop Bit Setting .11
Preset Settings . . . . . . . . . . . . . . . . . . . . . . . . . .12
To register preset positions . . . . . . . . . . . . . .12
Changing to Picture at Preset Position . . . . . .12
To tour the preset positions . . . . . . . . . . . . . .13
To group the preset positions . . . . . . . . . . . . .13
To tour the group . . . . . . . . . . . . . . . . . . . . . .14
To clear the preset position . . . . . . . . . . . . . .14
To clear all preset position . . . . . . . . . . . . . . .15
To clear a group . . . . . . . . . . . . . . . . . . . . . . .15
To set Alarm Input . . . . . . . . . . . . . . . . . . . . .16
To set Alarm Output . . . . . . . . . . . . . . . . . . . .16
Auto Pan Setup and Activation . . . . . . . . . . . . . . .17
To set the points of auto pan . . . . . . . . . . . . .17
To activate auto pan . . . . . . . . . . . . . . . . . . . .17
Pattern Setup and Activation . . . . . . . . . . . . . . . .18
To record the pattern . . . . . . . . . . . . . . . . . . .18
Pattern Play . . . . . . . . . . . . . . . . . . . . . . . . . .18
Privacy Setup . . . . . . . . . . . . . . . . . . . . . . . . . . .19
To register a new privacy zone . . . . . . . . . . . .19
To display or disappear privacy zone . . . . . . .19
4
Configuration Settings . . . . . . . . .
Operation . . . . . . . . . . . . . . . .
Focus Speed Setting . . . . . . .
PTZ Home Position . . . . . . . .
PTZ Position Reset . . . . . . . .
Remote PTZ Reset . . . . . . . .
Auto Key Lock Setting . . . . . .
To Change the User Password
Factory Reset . . . . . . . . . . . .
About LCC-K1000 . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.20
.20
.20
.20
.20
.21
.21
.21
.21
.21
Camera Control Function . . . . . . . . . . . . . . . . . .22
Pan/Tilt Control . . . . . . . . . . . . . . . . . . . . . . . . . .22
Lens Control . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . .23
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 5
About Dynamic Controller
This controller is the brand of Dome Camera Control Keyboard of LG in a surveillance system.You can operate
this system very easily and conveniently because of design structure based on biotechnology and various
functions for users. In addition, the controller can control using the whole functions of the LG Dome Camera
such as zoom, focus and Pan/Tilt heads.
Features
The Dynamic Controller offers the following functions:
x
User-friendly Graphic User Interface
x
Compatible with LG Dome Cameras and Zoom Cameras
x
Joystick Control of PTZ Functions
x
Program Preset Position up to 128 and Pattern Control
(Memorize continuous series of Zoom In/Out, Pan/Tilt)
x
Control Privacy Zone Masking
x
Easy Firmware Upgrade
(Please contact authorized service center or where you purchased to upgrade the firmware.)
x
Ergonomic Design
Note: The Dynamic Controller is not provided with functions to control the audio signal. Audio communication
is not possible, regardless of whether audio boards are installed in the receiver.
5
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 6
Identification of the Controller
1
q; qa
2
qs
qd
3 4 5
qf
qg qh
6
7
qj
8
qk ql w;
wa ws
6
9
wd
wf
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 7
1 PTZ1 / PTZ2 Button
Press to select a camera connected to the controller’s data ports.
Press PTZ1 to control the camera connected to
RS-485 1CH port.
Press PTZ2 to control the camera connected to
RS-485 2CH port.
2 Zone Buttons
For details, see page 19.
qd PTRN (Pattern) Buttons
For details, see page 18.
qf Alarm Buttons
For details, see pages 16.
qg Stop Button
Stops the playback of recorded images or pattern
playing back.
3 Back Buttons
This button is used to return to the previous menu
or mode.
qh CLR (CLEAR) Button
Clears the parameter entered with numeric buttons.
4 NUM Button
Press this button to change to numeric entering
mode on the menu.
qj SEL Button
This button is used to execute the currently
highlighted setting in the Setup menu.
5 Display Window
Displays function menus, numeric input, and
system status.
qk Open/Close Buttons
The lens iris is adjusted by pressing the OPEN or
CLOSE button.
6 Numeric (0-9) and Arrow (left/right/up/down)
Buttons
Selects an option in the menu.
These buttons are used for numeric input of preset numbers or for executing each parameter on
the Controller’s menu.
7 Set Up Button
Opens controller’s main Set Up menu in the display window.
8 OSD Button
Opens or closes the Camera’s Setup menu on
the screen.
9 Joystick Controller
This joystick manually operates the Pan/Tilt Head
and turning the joystick head to the right or left
will zoom or widen the image. (The zooming level
will go up or down.)
q; Preset Buttons
For details, see pages 12-14.
qa A-Pan (Auto-Pan) Buttons
For details, see page 17.
qs Func.1
Press the button to switch the LG Multix protocol
or LG Old protocol.
Func.6
If you use LG Multix Protocol, press the button to
change the AF Mode. (Auto or Manual) When the
AF Mode is PushAuto mode, press and hold the
button to activate the Auto Focusing and release
the button to inactivate the Auto Focus.
Func.2-5
These buttons are not assigned.
ql Near/Far Buttons
These buttons are used to adjust the lens focus
of cameras equipped with the specified lens.
w; In/Out Buttons
These buttons are used to zoom the camera
image In (TELE) and Out (WIDE).
wa RS-485 Data Ports (CH 2)
These ports are used to exchange control data
with the connected camera via the RS-485 cable.
To control the camera connected to this port,
press PTZ2 button on the controller.
ws RS-485 Data Ports (CH 1)
These ports are used to exchange control data
with the connected camera via the RS-485 cable.
To control the camera connected to this port,
press PTZ1 button on the controller.
wd RS-232C Port
Is used only for authorized service purposes.
wf DC 12V Input Jack (12V DC)
Connect a DC 12V Certified/Listed, class 2 power
supply only to the DC input terminal on the back
of the controller.
7
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 8
Connections
RS-485 Connection
5: TRX+
6: TRX-
Camera 1
Camera 2
RJ11 Cable (Supplied)
DC 12V cable
for Controller
Precautions
RS-485 Connection
•
The connections should be made by qualified
service personnel or system installers in accordance with all local codes.
•
DC 12V can be used.
Use the cable that is described below for RS-485 site
communication.
• Shielded, twisted pair cable
• Low impedance
• Wire gauge size is thicker than AWG #22
(0.33 mm 2).
6 TRX5 TRX+
1-4 GND
8
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:50 PM
Page 9
Setup Menu
Setup Menu Overview
The Setup menu has several submenus: System Setup, Preset Data Load, and Communication. All of these
main menus are further divided into submenus.
Main Menu
PRESET
AUTO PANNING
PATTERN
PRIVACY ZONE
COMMUNICATION
CONFIGURATION
Sub Menu
Set Preset
Go to Preset
Preset Tour
Edit Group
Group Tour
Clear Preset
Clear All Preset
Clear Group
Set Alarm Input
Set Alarm Output
Set Auto Panning
Run Auto Panning
Record Pattern
Play Pattern
Set Zone Area
Display Zone Area
Protocol Setting
Communication Speed
Parity Bit
Set Data Bits
Stop Bit
Manual Focus Speed
PTZ Home Position
PTZ Position Reset
Remote PTZ Reset
Auto Key Lock
Change Password
Factory Reset
About LCC-K1000
Page
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
11
11
11
11
11
20
20
20
21
21
21
21
21
9
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 10
Key Functions on the Set Up
Operation Start (Login)
Set Up button: To display the main menu.
Before starting operation, user authentication by the
password is required. (Refer to page 21 for details on
the setting of password.)
SEL button: To execute or select modes and parameters. To enter a submenu for the selected item.
Back button: To return to the previous menu.
CLR (CLEAR) button: Removes a number on the
menu.
NUM button: Switches to number entering mode in a
menu.
Numeric buttons: Enter numbered value in a menu.
Back button
1. Check that the camera, the monitor and peripherals are connected correctly and securely.
2. Connect an DC 12V power source to the DC 12V
input terminal on the back of the controller.
The display for entering your password appear in
the controller’s display window.
Please Input Password
NUM button
0-9
: Input
CLR
: Delete
3. Enter your 6-digit password using the number
buttons then press SEL.
The main menu will appears in the display window.
PRESET
Set Up button
SEL button
Number and Arrow buttons
CLR (CLEAR) button
10
000 PTZ
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 11
Communication Settings
Protocol Setting
This setting is required to establish a connection
between the system units and system controller.
This item lets you set a protocol for RS-485 communication.
You can select the desired parameter from
[LG MULTIX], [LG old], and [Reserved 1-6].
List of the communication settings
Setting Item Available setting parameter(s)
Protocol Setting:
LG MULTIX / LG old /
Reserved 1-6
Communication Speed (Baud Rate):
9,600 / 1,200 / 2,400 / 4,800 /
19,200 / 38,400 / 57,600 /
115,200 bps
Parity Bit:
NONE / ODD Parity /
EVEN Parity
Set Data Bits:
8 Data Bits / 9 Data Bits
Stop Bit:
1 bit (Fixed)
Note: Factory defaults are underlined.
Note: Using protocol of other model may cause
limitation of this function.
Communication Speed (Baud Rate)
Setting
The speed of communication between the system
controller and other system units.
You can select the desired parameter from 9,600 /
1,200 / 2,400 / 4,800 / 19,200 / 38,400 / 57,600 /
115,200 bps
Note: Conform this parameter to the baud rate of
other system units. Otherwise, communication will
not be established between the system controller and
system units.
Operation
PRESET
000 PTZ
1. Press the Set Up button then select the
[Communications] icon.
COMMUNICATION
000 PTZ
2. Press SEL.
The sub menu will appear for [COMMUNICATION]
setting.
PTZ
000
Protocol Setting
Communication Speed
Parity Bit
[vV:bB]
3. Press the PTZ1 or PTZ2 button then use number
buttons to select a camera’s number, if required.
4. Press SEL.
5. Use Arrow (M / m) buttons to select a desired
option then press SEL.
The display will change to the editing mode.
Parity bit
The parity bit, added to the data, to perform parity
check.
You can select the desired parameter from [NONE],
[ODD Parity], and [EVEN Parity].
Data Bits Setting
This item lets you set the number of the data bits for
RS-485 communication.
You can select the desired parameter from [8 Data
Bits] and [9 Data Bits].
Note: This setting must be compatible with the
peripherals connected.
Stop Bit Setting
The stop bit, added to the last of data, in
asynchronous communication.
The parameter is fixed to [1bit].
6. Use Arrow (M / m) button to select the desired setting then press SEL to confirm your selection.
11
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 12
9.
Preset Settings
Preset position is the function to register camera
monitoring positions (preset positions) associated
with position numbers.
By entering the position numbers, you can move
cameras to the preset positions.
Note: To activate this function, you need to register
the preset positions of combination camera.
To register preset positions
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
000 PTZ
Press NUM button then enter a [Park Time]
(holding time) (1-255). Then press SEL.
The position and its number are memorized for
later recall.
10. Repeat steps 4-9 to add additional position.
Changing to Picture at Preset Position
The following function is available only with cameras
provided with the preset function.
The preset function makes the combination camera
move to the programmed preset position.
It is necessary to program preset positions for the
combination camera beforehand.
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
000 PTZ
2. Press SEL.
The sub menu will appear for [PRESET] setting.
PTZ
000
Set Preset
Go to Preset
Preset Tour
2. Press SEL.
The sub menu will appear for [PRESET] setting.
[vV:bB]
3. Select [Go to Preset] option then press SEL.
The sub menu will appear.
3. Select [Set Preset] option then press SEL.
The sub menu will appear.
PTZ
000
Index
: --Speed
:
0
Park Time :
0
PTZ
000
[Num]
4. Press the PTZ1 or PTZ2 button then use number
buttons to select a camera’s number, if required.
5. Press SEL.
6. By moving the joystick, move the camera to a
point you wish.
7. Enter a [Index] number you wish to register by
pressing the numeric buttons then press SEL.
(0-127)
8. Press NUM button then enter a [Speed] (0-127) to
move to the preset position. Then press SEL.
12
PTZ
000
Set Preset
Go to Preset
Preset Tour
[vV:bB]
[Go To]
Preset Index: - - (0 ~ 127)
[Num]
4. Use number buttons to enter the memorized preset position’s index number then press SEL.
The camera moves to the preset position and the
picture of the camera in that position appears on
the monitor.
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 13
To tour the preset positions
To group the preset positions
You can tour all preset positions.
You can create a group using preset positions that
are registered already. A maximum of 9 group is
available.
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
000 PTZ
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
000 PTZ
2. Press SEL.
The sub menu will appear for [PRESET] setting.
3. Select [Preset Tour] option then press SEL.
The sub menu will appear.
PTZ
000
2. Press SEL.
The sub menu will appear for [PRESET] setting.
3. Select [Edit Group] option then press SEL.
The sub menu will appear.
Set Preset
Go to Preset
Preset Tour
[vV:bB]
PTZ
000
Edit Group
Group Tour
Clear Preset
[vV:bB]
[Preset Touring]
Are you sure?
PTZ
000
SEL : OK
PTZ
000
4. Press SEL.
All registered preset positions in the camera will
be selected, and the camera position image will be
switched on the active monitor.
5. You can stop the tour by pressing Stop button or
moving the joystick.
Group Index : 1
Preset Index : --[v:V]
4. Use Arrow (M / m) buttons to select [Preset Index]
option.
5. Press NUM button then enter the index number
that is already registered.
6. Press SEL.
The index number is added to the group.
Note: A group can contain up to 8 preset numbers.
7. Repeat steps 4-6 to additional index number.
Note: The available groups and indexes differ
depending on cameras. So please refer to camera’s manual.
13
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 14
To tour the group
To clear the preset position
You can tour the group that is registered already.
You can delete a memorized preset position.
1. Press the Set Up button then select the [PRESET]
icon.
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
2. Press SEL.
The sub menu will appear for [PRESET] setting.
3. Select [Group Tour] option then press SEL.
The sub menu will appear.
PTZ
000
PTZ
000
Edit Group
Group Tour
Clear Preset
[vV:bB]
[Group Touring]
Group Index: --(1 ~ 9)
[Num]
4. Use number buttons to enter the group number
that is registered already then press SEL.
The camera moves to the preset position in the
group and the picture of the camera in that position appears on the monitor.
14
PRESET
000 PTZ
000 PTZ
2. Press SEL.
The sub menu will appear for [PRESET] setting.
3. Select [Clear Preset] option then press SEL.
The sub menu will appear.
PTZ
000
PTZ
000
Edit Group
Group Tour
Clear Preset
[vV:bB]
[Clear Preset]
Preset Index: --(0 ~ 127)
[Num]
4. Use number buttons to enter the memorized preset index number then press SEL.
The preset position will be deleted.
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 15
To clear all preset position
To clear a group
You can delete all memorized preset position.
You can delete a memorized group.
1. Press the Set Up button then select the [PRESET]
icon.
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
PRESET
000 PTZ
000 PTZ
2. Press SEL.
The sub menu will appear for [PRESET] setting.
2. Press SEL.
The sub menu will appear for [PRESET] setting.
3. Select [Clear All Preset] option then press SEL.
The sub menu will appear.
3. Select [Clear Group] option then press SEL.
The sub menu will appear.
PTZ
000
Clear All Preset
Clear Group
Set Alarm Input
PTZ
000
[vV:bB]
[Clear All Preset]
Are you sure?
PTZ
000
Clear All Preset
Clear Group
Set Alarm Input
SEL : OK
PTZ
000
[Clear Group]
Group Index: --(1~9)
[vV:bB]
[Num]
4. Use number buttons to enter the memorized group
index number then press SEL.
The group will be deleted.
4. Press SEL to delete all preset positions.
Press Back to return to the previous menu screen.
15
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 16
To set Alarm Input
To set Alarm Output
You can set alarm input mode, alarm index, and
duration time. Preset numbers 1 to 8 are linked to
alarm inputs 1 to 8 respectively. If alarm input 1
comes in, the camera turns to preset position 1, and
to other positions according to alarm input 2 to 8.
(This operating description is based on the LG product.)
You can set alarm output mode, alarm index, and
duration time. When alarm inputs are supplied via the
alarm input connector on the camera, the camera
sends output signals via the alarm output connector
on the camera.
Alarm output numbers 1 to 4 are linked to alarm
inputs 1 to 4 respectively. If alarm input 1 comes in,
the camera sends output signals via the alarm
output 1 connector on the camera.
(This operating description is based on the LG product.)
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
000 PTZ
Note: You cannot use this function with a camera
without alarm output connector.
2. Press SEL.
The sub menu will appear for [PRESET] setting.
1. Press the Set Up button then select the [PRESET]
icon.
PRESET
000 PTZ
3. Select [Set Alarm Input] option then press SEL.
The sub menu will appear.
PTZ
000
PTZ
000
Clear All Preset
Clear Group
Set Alarm Input
2. Press SEL.
The sub menu will appear for [PRESET] setting.
[vV:bB]
Alarm Input
: OFF
Alarm Index
: --Duration Time : - - <4:OFF , 6:ON>
[Num]
4. Use 4 (ON) or 6 (OFF) buttons to select Alarm
Input Mode then press SEL.
ON: Alarm input signals are supplied from external
devices through the ALARM IN connector on the
camera to turn the camera to a preset position.
OFF: The camera ignores alarm inputs.
5. Enter a [Alarm Index] number (1-8).
Note: The available alarm index differ depending
on cameras. So please refer to camera’s manual.
16
3. Select [Set Alarm Output] option then press SEL.
The sub menu will appear.
Set Alarm Ouput
PTZ
000
PTZ
000
[vV:bB]
Alarm Output : ON
Alarm Index
: --Duration Time : - - <4:OFF , 6:ON>
[Num]
4. Use 4 (ON) or 6 (OFF) buttons to select Alarm
Output Mode then press SEL.
ON: If alarm input comes in, the camera sends
output signals.
OFF: The camera does not send an output signal.
6. Enter a [Duration Time] (0-255) then press SEL.
Displays the picture at the preset position for the
selected duration. (0 (Manual mode); the camera
hold at the preset position continuously. To escape
Manual mode, set the [Alarm Input] to OFF.)
Alarm input setting is finished and the setting is
memorized to the camera’s memory.
5. Enter a [Alarm Index] number (1-4).
7. Repeat steps 4-6 to set additional Alarm Input.
7. Repeat steps 4-6 to set additional Alarm Output.
6. Enter a [Duration Time] (1-255) then press SEL.
Sends the output signals for the selected duration.
(0 (Manual mode); the camera sends output signals continuously.)
Alarm output setting is finished and the setting is
memorized to the camera’s memory.
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 17
Auto Pan Setup and Activation
To activate auto pan
You will set up and activate the auto pan function.
The camera can pan among the points you will set.
Note: Refer to the operating instructions of camera
for details on the auto pan function.
1. Press the Set Up button then select the [AUTO
PANNING] icon.
AUTO PANNING
000 PTZ
To set the points of auto pan
1. Press the Set Up button then select the [AUTO
PANNING] icon.
AUTO PANNING
000 PTZ
2. Press SEL.
The sub menu will appear for [AUTO PANNING]
setting.
3. Select [Run Auto Panning] option then press SEL.
The sub menu will appear.
2. Press SEL.
The sub menu will appear for [AUTO PANNING]
setting.
PTZ
000
3. Select [Set Auto Panning] option then press SEL.
The sub menu will appear.
PTZ
000
Set Auto Panning
Run Auto Panning
PTZ
000
Set Auto Panning
Run Auto Panning
[vV:bB]
[Run Auto Panning]
Are you sure?
SEL : OK
[vV:bB]
4. Press SEL to activate auto pan.
PTZ
000
[A-Pan No.#
Speed
:
Park Time :
1]
50
2
[vV]
4. Press the PTZ1 or PTZ2 button then use number
buttons to select a camera’s number, if required.
5. By moving the joystick, move the camera to a
point you wish.
6. Press NUM button then enter a [Speed] (0-127) to
move to the preset position. Then press SEL.
7. Press NUM button then enter a [Park Time] (holding time) at the preset position (0-255).
The setting is finished and the setting is memorized to the camera’s memory.
8. Repeat steps 4-7 to add additional position.
17
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 18
Pattern Setup and Activation
You will perform the pattern setup and the pattern
play.
Note: The available patterns differ depending on
camera. So please refer to camera’s manual.
Note: Press CLR or Back button if you cancel the
recording during recording a pattern.
To record the pattern
1. Press the Set Up button then select the [PATTERN] icon.
PATTERN
7. Perform desired camera operations by moving the
joystick or pressing In/Out buttons.
The following controls are available for recording
the pattern.
• Panning/Tilting/Zoom control (joystick)
• Zoom control (In/Out buttons)
000 PTZ
8. If you finish to record, press SEL.
The pattern is memorized in the camera’s memory.
9. Repeat steps 3-8 to add additional position.
Note: The available total time of pattern differs
depending on camera’s operation. When the time is
over, the pattern setup will automatically stop.
2. Press SEL.
The sub menu will appear for [PATTERN] setting.
Pattern Play
3. Select [Record Pattern] option then press SEL.
The sub menu will appear.
You can activate the pattern play function for the
selected camera.
4. Press the PTZ1 or PTZ2 button then use number
buttons to select a camera’s number, if required.
1. Press the Set Up button then select the [PATTERN] icon.
PATTERN
5. Press SEL.
000 PTZ
6. Use number buttons to select the pattern index
number then press SEL to confirm.
Pattern recording starts.
PTZ
000
PTZ
000
2. Press SEL.
The sub menu will appear for [PATTERN] setting.
Record Pattern
Play Pattern
[vV:bB]
PTZ
000
[Record Pattern]
Pattern No : --(1 ~ 4)
Record Pattern
Play Pattern
[vV:bB]
[Num]
PTZ
000
[Rec. Pattern]
Pattern rec ...
PTZ
000
3. Select [Play Pattern] option then press SEL.
The sub menu will appear.
[Num]
[Play Pattern]
Pattern No: --(1 ~ 4)
[Num]
4. Use number buttons to enter the memorized pattern index number then press SEL.
The camera plays the pattern.
5. Press Stop button or move the joystick to stop
playing.
18
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 19
Privacy Setup
To display or disappear privacy zone
This setting is used for masking unwanted zones,
hiding them from display on the monitor screen.
Up to 8 zones can be registered. Submenus are provided for zone number selection and parameter setting.
1. Press the Set Up button then select the [PRIVACY
ZONE] icon.
PRIVACY ZONE
000 PTZ
To register a new privacy zone
1. Press the Set Up button then select the [PRIVACY
ZONE] icon.
PRIVACY ZONE
000 PTZ
2. Press SEL.
The sub menu will appear for [PRIVACY ZONE]
setting.
3. Select [Display Zone Area] option then press SEL.
The sub menu will appear.
2. Press SEL.
The sub menu will appear for [PRIVACY ZONE]
setting.
PTZ
000
3. Select [Set Zone Area] option then press SEL.
The sub menu will appear.
PTZ
000
PTZ
000
Set Zone Area
Display Zone Area
PTZ
000
[vV:bB]
[Set Privacy Zone]
Zone Index : --(1 ~ 8)
[Num]
4. Press the PTZ1 or PTZ2 button then use number
buttons to select a camera’s number, if required.
5. Press SEL.
Set Zone Area
Display Zone Area
[vV:bB]
Display
: OFF
Zone Index
: --(1~8)
<4:OFF , 6:ON>
[Num]
4. Use 4 (ON) or 6 (OFF) buttons to select Alarm
Input Mode then press SEL.
ON: Preset privacy zones are veiled on the monitor screen.
OFF: The veiling function does not work.
5. Enter a [Zone Index] number (1-8).
The display zone setting has been completed and
the setting is memorized to the camera’s memory.
6. Repeat steps 4-5 to set additional zone.
6. Use number buttons to select the zone index number then press SEL to confirm.
The zone frame appears on the monitor.
7. Adjust the pan, tilt, and zoom position so that the
desired position comes into the zone frame with
the joystick.
8. Press SEL.
The privacy zone setting has been completed and
the setting is memorized in the camera’s memory.
9. Repeat steps 3-8 to add additional position.
19
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 20
Configuration Settings
PTZ Home Position
In this menu, you can customize the settings provided.
The home position is the camera’s basic position.
The camera returns to this position after executing
the [PTZ Home Position] option.
Operation
1. Press the Set Up button then select the
[CONFIGURATION] icon.
CONFIGURATION
000 PTZ
2. Press SEL.
The sub menu will appear for [CONFIGURATION]
setting.
3. Use Arrow (M / m) buttons to select a desired
option.
PTZ
000
Manual Focus Speed
PTZ Home Position
PTZ Position Reset
[vV:bB]
PTZ
000
PTZ
000
[vV:bB]
[Go To Home]
Are you sure ?
SEL : OK
PTZ Position Reset
You can reset the connected PTZ camera’s position
automatically.
0 : Disable the PTZ position reset.
1~90 : Reset the PTZ position once per number of
days you set.
4. While the desired menu option is selected, press
SEL and the sub menu will appear.
5. Use Arrow (M / m) buttons to select the desired
setting then press SEL to confirm your selection.
Some menu options require additional steps.
PTZ
000
6 Press Back button to return to the previous menu
or press Set Up to return to the main menu.
PTZ
000
Focus Speed Setting
You can select a shutter speed from among LOW,
MIDDLE, or HIGH
PTZ
000
PTZ
000
20
Manual Focus Speed
PTZ Home Position
PTZ Position Reset
[vV:bB]
LOW Speed
MIDDLE Speed
HIGH Speed
[vV]
[vV:bB]
[Reset PTZ Position]
Period : every - - - Day
(0, 1~90)
SEL : OK
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 21
Remote PTZ Reset
You can reset the connected PTZ camera’s parameters to the factory default settings.
PTZ
000
PTZ
000
Remote PTZ Reset
Auto Key Lock
Change Password
[vV:bB]
[ Reset PTZ Camera ]
Are you sure?
Auto Key Lock Setting
The keys on the controller is locked when there is no
operation for selected duration on the [Auto Key
Lock] option. To release the Key Lock mode, you
need to enter the password.
NONE: Auto Key Lock function is disable.
After 1 min.: The keys on the controller is locked
when there is no operation for 1 minutes.
After 3 min.: The keys on the controller is locked
when there is no operation for 3 minutes.
PTZ
000
PTZ
000
NONE
After 1 min.
After 3 min.
PTZ
000
[vV:bB]
Current:
New:
Confirm:
[Num]
2. Enter current 6-digit password using the number
buttons then press SEL.
SEL : OK
Remote PTZ Reset
Auto Key Lock
Change Password
PTZ
000
Remote PTZ Reset
Auto Key Lock
Change Password
[vV:bB]
[vV]
3. Enter new 6-digit password using the number buttons then press SEL. Enter the password again to
confirm, and press SEL. The password is stored.
Note: We recommend that you do not operate the
controller during saving the password.
Factory Reset
You can reset the controller’s parameters to the factory default settings. You need to enter the password.
PTZ
000
PTZ
000
PTZ
000
Factory Reset
About LCC-K1000
[vV:bB]
Password: -----[Num]
[ Reset PTZ Camera ]
Are you sure?
SEL : OK
About LCC-K1000
To Change the User Password
The factory default of password is “000000”.
However, for security, you should change the password setting.
1. Select [Change Password] option then press SEL.
The sub menu will appears.
Shows model name and the current firmware version
of the controller.
PTZ
000
PTZ
000
Factory Reset
About LCC-K1000
[vV:bB]
[ About LCC-K1000 ]
LG Electronics Inc.
Firmware ver. 1.00
SEL : OK
21
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 22
Camera Control
Function
Camera control functions are operable.
It is necessary to set up the camera before using the
camera control functions. For further information,
refer to the Operating Instructions for the respective
combination camera. You can also set it up from the
Camera Setup menu during operating the system.
Lens Control
The following functions are available with cameras
provided with controllable lens.
1
Pan/Tilt Control
2
A combination camera or an ordinary camera with
pan/tilt head can be controlled.
3
Move the pan/tilt head in the desired direction using
the joystick.
1
1. Press the In button to optically bring the object
closer, or press the Out button to optically widen
the scene.
Tip: Turning the joystick head to the right or left
will zoom or widen the image. (The zooming level
will go up or down.)
Note: Focal length differs depending on the lens
installed on the camera.
2. Press the Near or Far button to adjust the lens
focus while watching the monitor.
3. Press the Open or Close button to adjust the lens
iris while watching the monitor.
22
LCC-K1000_AABBLLG_ENG_75N
7/19/06
1:51 PM
Page 23
Reference
Specifications
Communication
Signal
RS-485
Connector
RJ11
Baud Rate
1,200 / 2,400 / 4,800 / 9,600 / 19,200 / 38,400 /
57,600 / 112,500 bps
Joy-Stick Type
3-Axis
Control
256 Camera ID / Protocol Selection / Alarm Control
Pan / Tilt / Zoom / Iris Focus
128 Positions Preset Touring
8 Positions Auto Panning
4 Pattern Setting
Privacy Zone Masking (8 zones)
Firmware Update
RS-232C
Total Key Number
44
Password
6 Digits
Display
4 Gray Graphic LCD (256 x 72 dots)
Operation Temp. / Humidity
-10 °C ~50 °C / 0%RH ~ 80%RH
Storage Temp. / Humidity
-20 °C ~60 °C / 0%RH ~ 85%RH
Supplied Voltage
DC12V, 125mA
Weight
1kg
Dimension(H x V x D)
419 x 110 x 190mm