LG | LS300P-B1 | LG LS300P-B1 Owner’s Manual

Color Video Camera
Instruction Manual
Models : LS300N-D1
LS300P-D1
LS300N-B1
LS300P-B1
LS300P-C1
Before installing, operating or adjusting this
product, please read this instruction booklet
carefully and completely.
CAUTION
RISK OF ELECTRIC SHOCK �
DO NOT�OPEN
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
This lightning flash with arrowhead symbol
within an equilateral triangle is intended to
alert the user to the presence of uninsulated
dangerous voltage within the product’s
enclosure that may be of sufficient magnitude to constitute a risk of electric shock to
persons.
The exclamation point within an equilateral
triangle is intended to alert the user to the
presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
FCC WARNING: This equipment may generate or
use radio frequency energy. Changes or modifications
to this equipment may cause harmful interference
unless the modifications are expressly approved in the
2
instruction manual. The user could lose the authority
to operate this equipment if an unauthorized change
or modification is made.
REGULATORY INFORMATION: FCC Part 15
This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and
used in accordance with the instruction manual, may
cause harmful interference to radio communications.
Operation of this equipment in a residential area is
likely to cause harmful interference in which case the
user will be required to correct the interference at his
own expense.
•
•
A suitable conduit entries, knock-outs or glands
shall be provided in the cable entries of this product in the end user.
Caution: Danger of explosion if battery is incorrectly replaced. Replaced only with the same or
equivalent type recommended by the manufacturer. Dispose of used batteries according to the
manufacturer’s instructions.
•
Holes in metal, through which insulated wires
pass, shall have smooth well rounded surfaces or
shall be provided with brushings.
Disposal of your old appliance
1. When this crossed-out wheeled bin
symbol is attached to a product it means
the product is covered by the European
Directive 2002/96/EC.
2. All electrical and electronic products
should be disposed of separately from
municipal waste stream via designated
collection facilities appointed by the government or the local authorities.
3. The correct disposal of your old appliance
will help prevent potential negative consequences for the environment and human
health.
4. For more detailed information about
disposal of your old appliance, please
contact your city office, waste disposal
service or the shop where you purchased
the product.
Warning: Do not install this equipment in a confined
space�such as a bookcase or similar unit.
Warning: Wiring methods shall be in accordance with
the�National Electric Code, ANSI/NFPA 70.
Warning: This is a class A product. In a domestic
environment this product may cause radio interference in which case the user may be required to take
adequate measures.
Warning: To reduce a risk of fire or electric shock, do
not expose this product to rain or moisture.
Caution: This installation should be made by a qualified�service person and should conform to all local
codes.
Caution: To avoid electrical shock, do not open the
cabinet.�Refer servicing to qualified personnel only.
Caution: The apparatus should not be exposed to
water�(dripping or splashing) and no objects filled
with�liquids, such as vases, should be placed on the
apparatus.
This product is manufactured to com ply with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC.
European representative :
To disconnect power from the mains, pull out the
mains cord plug. When install the product, ensure
that the plug is easily accessible.
This class [A] digital apparatus complies with Canadian ICES-003
Get appareil numerique de la classe [A] est conforme a la norme
NMB-003 du canada
3
Important Safety Instructions
1. Read these instructions. - All these safety and
operating instructions should be read before the
product is operated.
2. Keep these instructions. - The safety, operating
and use instructions should be retained for future
reference.
3. Heed all warnings. - All warnings on the product and in the operating instructions should be
adhered to.
4. Follow all instructions. - All operating and use
instructions should be followed.
5. Do not use this apparatus near water. - For
example: near a bath tub, wash bowl, kitchen sink,
laundry tub, in a wet basement; near a swimming
pool; etc.
6. Clean only with dry cloth. - Unplug this product
from the wall outlet before cleaning. Do not use
liquid cleaners.
4
7. Do not block any ventilation openings. Install
in accordance with the manufacturer's instructions. - Slots and openings in the cabinet are
provided for ventilation, to ensure reliable operation of the product, and to protect it from overheating. The openings should never be blocked
by placing the product on a bed, sofa, rug or other
similar surface. This product should not be placed
in a built-in installation such as a bookcase or
rack unless proper ventilation is provided and the
manufacturer’s instructions have been adhered to.
8. Do not install near any heat sources such as
radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Important Safety Instructions
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug
has two blades with one wider than the other. A
grounding type plug has two blades and a third
grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete
outlet.
13. Unplug this apparatus during lightning storms or
10. Protect the power cord from being walked on
when unused for long periods of time.
or pinched particularly at plugs, convenience
receptacles, and the point where they exit from
14.Refer all servicing to qualified service personthe apparatus.
nel. Servicing is required when the apparatus
has been damaged in any way, such as power11. Only use attachments/accessories specified by
supply cord or plug is damaged, liquid has
the manufacturer.
been spilled or objects have fallen into the
apparatus, the apparatus has been exposed to
12. Use only with the cart, stand, tripod, bracket,
rain or moisture, does not operate normally, or
or table specified by the manufacturer, or sold
has been dropped.
with the apparatus. When a cart is used, use
caution when moving the cart/apparatus combination to avoid injury from tip-over.
5
Cautions for Safe Operation
Power Supply
Operating and storage location
This camera must always be operated a AC 24V
or DC 12V or AC 230V Certified/Listed, class 2
power supply only.
Avoid viewing a very bright object (such as
light fittings) during an extended period.
Avoid operating or storing the unit in the
following locations.
Handling of the unit
• Extremely hot or cold places (operating
temperature -10oC~50oC, however, we
recommend that the unit be used within a
temperature range of 0oC~45oC)
• Damp or dust place
• Places exposed to rain
• Places subject to strong vibration
• Close to generators of powerful
electromagnetic radiation such as radio or
TV transmitters.
Be careful not to spill water or other liquids
on the unit. Be cautions not to get combustible
or metallic material inside the body. If used
with foreign matter inside, the camera is liable
to fail or to get a cause of fire or electric shock.
6
Contents
Cautions for Safe Operation ............................................................................... 6
Models ................................................................................................................ 7
Operating Controls and Their Functions .......................................................... 8-9
OSD Menu ................................................................................................... 10-25
AREA Setting ................................................................................................... 26
Specifications ............................................................................................... 27-28
Models
Models
Signal System
Power
LS300N-D1
NTSC
PAL
DC 12V
DC 12V
AC 230V
DC 12V / AC 24V
LS300P-D1
LS300P-C1
LS300N-B1
LS300P-B1
PAL
NTSC
PAL
DC 12V / AC 24V
7
Operating Controls and their Functions
VIDEO
OUT
POWER
AUTO IRIS
VIDEO
OUT
POWER
DC ELC VIDEO
DC ELC VIDEO
DC12V
AC24V
+ DC12V ㅡ
+
CLASS 2 ONLY
LS300N(P)-D1
8
Tripod adapter
CCD cover
C/CS adjustment lever
Auto iris lens connector
OSD switch
Power LED
BNC connector for video output
Lens selection switch
Power input connector
Power input terminal
CLASS 2 ONLY
VIDEO
OUT
POWER
1
2
3
4
5
6
7
8
9
10
ㅡ
LS300N(P)-B1
DC ELC VIDEO
POWER IN
AC230V
10
LS300P-C1
Pin assignment of auto iris lens connector
3
4
1
2
Pin No.
1
2
3
4
DC iris
Damping Damping +
Drive +
Drive -
Video iris
Vcc (+9V)
Not used
Video
Ground
Lens Mounting
C/CS adjustment lever
1. Loosen the C/CS adjustment lever
2. Hold up the lever to change the mount to CS / Hold down the
lever to change the mount to C
3. Tighten the C/CS adjustmet lever
CAUTION
Be cautious not to use Auto Iris Lens with over 30mA.
DC iris level is preset in the factory. Only if necessary, adjust the DC
iris level to achieve the proper picture with AGC off.
DC
ELC
VIDEO
Auto Iris Mode Selection
POSITION
LENS
DC
DC iris lens
ELC
Manual or fixed iris lens
VIDEO
Video iris lens
POWER
VIDEO
OUT
DC ELC VIDEO
+ DC 12V
1. Set the auto iris mode selection switch to the position that
corresponds to the lens which is mounted to the camera.
Please refer to the table on the up.
2. OSD Setting : Refer to 12 page (OSD MENU - Lens)
9
OSD MENU
LENS
SHUTTER
DC / VIDEO / MANUAL
AUTO (0~255 steps) / FLK / FIXED (1/60-1/50 ~1/100,000 sec) / MANUAL (0~255 steps)
BLC
ON / OFF
AGC
ON / OFF
WHITE BAL.
FUNCTION
ATW / AWB / FIXED / MANUAL
CAMERA ID
ON / OFF
MIRROR
ON / OFF
DAY & NIGHT
AUTO / COLOR / BW
MOTION
ON / OFF
PRIVACY
ON / OFF
GAMMA
0.05 ~ 1.00 / USER
LANGUAGE
ENGLISH / KOREAN / CHINESE1(SC) / CHINESE2(DC) / JAPANESE
RESET
ADJUST
CONTRAST / SHARPNESS / CB_GAIN / CR_GAIN
EXIT
10
OSD MENU - Setting
Settings can be made using the 5 buttons
located on the back of the camera.
POWER
UP BUTTON
VIDEO
OUT
LEFT BUTTON
1 SETUP
DC ELC VIDEO
DOWN BUTTON
RIGHT BUTTON
+ DC 12V
2. Please select any function you wish to activate
by using the UP and DOWN buttons.
SETUP
2
4
LENS
SHUTTER
BLC
AGC
WHITE BAL.
FUNCTION
ADJUST
EXIT
1. Please press the SETUP button.
- Settings can now be made.
The SETUP menu is displayed on the monitor.
DC
FIXED
OFF
ON
AWB
3
3. Please press the LEFT or RIGHT button if you
wish to change mode.
4. Please select 'EXIT' and then press the SETUP
button to finish the setting.
11
OSD MENU - LENS
Please select the type of the lens you wish to use by pressing the LEFT or
RIGHT button.
LENS DC
SETUP
LENS
SHUTTER
BLC
AGC
WHITE BAL.
FUNCTION
ADJUST
EXIT
DC
FIXED
OFF
ON
AWB
• DC/VIDEO : Auto iris lens selection
• MANUAL : Manual lens selection
BRIGHTNESS
200
: RETURN
• DC mode - Brightness setting(0~255 steps)
* When using an auto iris lens, the setting of the auto iris lens selection switch, located on the
back of the camera, must be on DC or ELC or VIDEO depending on the type of the lens which is
being used.
* When it is ‘RESET’ , ‘LENS’ comes to be initialized to ‘DC’ .
12
OSD MENU - SHUTTER
Please select the shutter mode by pressing the LEFT or RIGHT button.
• AUTO : Please select ‘AUTO’ and then press the SETUP
SETUP
LENS
SHUTTER
BLC
AGC
WHITE BAL.
FUNCTION
ADJUST
EXIT
button to ‘AUTO’ the setting.
Auto Control of the shutter speed can be achieved.
Adjust range : 0 ~ 255 steps
DC
FIXED
OFF
ON
AWB
• FLK
: 'FLK' mode when flickering occurs on the screen,
due to an imbalance between illumination and
frequency.
- When selecting FLK mode, the shutter FIXED
mode is fixed at 1/100(1/120).
• FIXED : The shutter speed can be controlled manually.
Adjust range : 1/60 ~ 1/100,000 sec (NTSC)
1/50 ~ 1/100,000 sec (PAL)
• MANUAL : The shutter speed can be controlled manually.
Adjust range : 0(Shutter slow) ~ 255(Shutter fast) steps.
- When selecting DC/VIDEO lens, the shutter speed is ‘FIXED’ mode(1/60 or 1/50).
- When selecting MANUAL lens, the shutter speed is ‘AUTO’ mode.
13
OSD MENU - BLC(Backlight compensation)
Please select the mode you wish to operate by pressing the LEFT or RIGHT button.
BLC ON
SETUP
LENS
SHUTTER
BLC
AGC
WHITE BAL.
FUNCTION
ADJUST
EXIT
DC
FIXED
ON
ON
AWB
BLC AREA
BLC OFF
• ON : You can adjust the sensitivity and BLC area of backlight compensation.
When there is a strong backlight behind the object(within the BLC AREA),
Clear images of the object can still be obtained by using the BLC function.
• OFF : Backlight compensation function does not operate.
* Please select ‘ON’ and the press the SETUP button to BLC the setting.
- BLC AREA : Please select all the area you wish to observe.
>Press the SETUP switch long. Enters with the set window. (Refer to 26 page : Area Setting.)
- BLC RATIO : The brightness can be adjusted level.
To control the brightness of the object ‘0(increase)’ to 63(decrease)’.
14
OSD MENU - AGC(Auto Gain Control)
Please select the mode you wish to operate by pressing the LEFT or RIGHT button.
SETUP
LENS
SHUTTER
BLC
AGC
WHITE BAL.
FUNCTION
ADJUST
EXIT
AGC CONTROL
DC
FIXED
OFF
ON
AWB
AGC GAIN
180
: RETURN
• The BRIGHTNESS can be adjusted within the range of 0 ~ 255 steps.
* If AGC OFF, DAY & NIGHT AUTO mode is not working.
- Refer to 19 page. (DAY & NIGHT setting)
15
OSD MENU - WHITE BALANCE control
Please select the mode you wish to operate by pressing the LEFT or RIGHT button.
• ATW(Auto Tracking White Balance) :
SETUP
LENS
SHUTTER
BLC
AGC
WHITE BAL.
FUNCTION
ADJUST
EXIT
16
DC
FIXED
OFF
ON
AWB
This mode can be used out of the color temperature
range 2,500K ~ 9,500K
• AWB(Auto White Balance) :
This is a preset type function whereby white color in the
scene is detected and white balance is automatically
adjusted, then the setting status is stored.
This mode can be used within the color temperature
range 2,500K ~ 9,500K.
• FIXED :
WHITE BALANCE can be controlled manually.
Preset type - MODE1 : 2,500K(indoor)
MODE2 : 3,200K(indoor)
MODE3 : 5,100K(outdoor)
MODE4 : 9,500K(outdoor)
• MANUAL :
This allows adjusting red and blue gain manually
according to requirements.
OSD MENU - FUNCTION > ID Setup
1. Please position the highlight to point to 'FUNCTION' on the SETUP menu by
using the UP and DOWN buttons.
2. Please select the mode you wish to operate by pressing the UP or DOWN button.
ID SETUP
FUNCTION
CAMERA ID
MIRROR
DAY NIGHT
MOTION
PRIVACY
GAMMA
LANGUAGE
RESET
RETURN
ON
OFF
AUTO
OFF
OFF
0.45
ENGLISH
CAMERA ID
CAMERA ID
C
CAM 01
POSITION
RETURN
If you press the SETUP button after moving cursor to 'C', all the letters will be erased.
Using the MENU key to set character postion.
17
OSD MENU - FUNCTION > MIRROR
MIRROR OFF
FUNCTION
CAMERA ID
MIRROR
DAY NIGHT
MOTION
PRIVACY
GAMMA
LANGUAGE
RESET
RETURN
OFF
ON
AUTO
OFF
OFF
0.45
ENGLISH
• ON : Set a horizontal image inversion.
• OFF : Cancels the inversion.
18
MIRROR ON
OSD MENU - FUNCTION > DAY & NIGHT
Please select the mode you wish to operate by pressing the LEFT or RIGHT button.
• AUTO : The camera selects black and white mode.
FUNCTION
CAMERA ID
MIRROR
DAY NIGHT
MOTION
PRIVACY
GAMMA
LANGUAGE
RESET
RETURN
OFF
OFF
AUTO
OFF
OFF
0.45
ENGLISH
If the picture is dark, on color mode if the picture is
bright enough.
Please select 'AUTO' and then press the SETUP
button to DAY&NIGHT setting.
- DELAY : Delay time when the DAY&NIGHT function starts or stops.
(0~63 sec)
- START LEVEL : Set the brightness level where the DAY&NIGHT start to
operate. 0(high light)~255(low light)
- END LEVEL : Set the brightness level where the DAY&NIGHT function
stop operating. 0(high light)~255(low light)
• COLOR : Color mode enabled.
• B / W : Black and White mode enabled.
Please select 'B/W' and then press the SETUP
button to BURST the setting.
- BURST ON : BURST signal 'ON'
- BURST OFF : BURST signal 'OFF'
19
OSD MENU - FUNCTION > DAY & NIGHT
※Operating Conditions
1) Due to the connection with the value of AGC, it doesn't work when "AGC OFF".
2) Delay time shall be more than 1sec.(at least).
(with the value "0", it is in "DAY MODE" continuously.)
3) Because a start level is connected with the value of AGC, A start level shall be set less
than the value of AGC.
4) A start level shall be higher than an end level.
20
OSD MENU - FUNCTION > Motion Detection
Please select the area you wish to observe from the 64 areas in Area selection
mode.
FUNCTION
CAMERA ID
MIRROR
DAY NIGHT
MOTION
PRIVACY
GAMMA
LANGUAGE
RESET
RETURN
Motion ICON
OFF
OFF
AUTO
ON
OFF
0.45
ENGLISH
Motion Detection
Please select 'ON' and then press the SETUP
button to MOTION the setting.
• OFF : MOTION DETECTION mode is cancelled.
• ON : Any motion in the selected areas is observed.
- AREA : Set the MOTION area.
> Press the SETUP switch long. Enters with the set window.
(Refer to 26 page : Area Setting.)
- MOTION TH : High luminous motion theshold value
To control the MOTION TH.
‘0(sensitivity)’ to ‘255(insensitivity)’
- MOTION TRACE : ON - MOTION TRACE 'ON'
OFF - MOTION TRACE 'OFF'
21
OSD MENU - FUNCTION > PRIVACY
This modes conceals the areas you do not wish to appear on the screen.
FUNCTION
CAMERA ID
MIRROR
DAY NIGHT
MOTION
PRIVACY
GAMMA
LANGUAGE
RESET
RETURN
OFF
OFF
AUTO
OFF
ON
0.45
ENGLISH
• OFF : Cancels the PRIVACY mode.
• ON : Operates the PRIVACY mode.
22
PRIVACY ZONE
* Please select 'ON' and then press the SETUP button
to PRIVACY the setting.
- Select an area to mask from the 4 areas in AREA SEL
- Change the AREA STATE of the selected area to 'ON'
- From COLOR, press the Left/Right buttons to control the color.
- Set the area size from the LEFT/RIGHT/TOP/BOTTOM menu,
and then press the SETUP button.
OSD MENU - FUNCTION > GAMMA
Select a GAMMA value.
FUNCTION
CAMERA ID
MIRROR
DAY NIGHT
MOTION
PRIVACY
GAMMA
LANGUAGE
RESET
RETURN
OFF
OFF
AUTO
OFF
OFF
0.45
ENGLISH
• Select [GAMMA] option on the [FUNCTION] screen.
• Press LEFT or RIGHT button to select a GAMMA.
To control the brightness,
'0.05(increase)' to '1.00(decrease), USER'
23
OSD MENU - FUNCTION > LANGUAGE
Select a LANGUAGE for the setup menu and
on-screen display.
FUNCTION
CAMERA ID
MIRROR
DAY NIGHT
MOTION
PRIVACY
GAMMA
LANGUAGE
RESET
RETURN
24
OFF
OFF
AUTO
OFF
OFF
0.45
ENGLISH
• Select [LANGUAGE] option on the [FUNCTION]
screen.
• Press LEFT or RIGHT button to select a LANGUAGE.
- ENGLISH
- KOREAN
- CHINESE1(SC)
- CHINESE2(DC)
- JAPANESE
OSD MENU - ADJUST
ADJUST
SETUP
LENS
SHUTTER
BLC
AGC
WHITE BAL.
FUNCTION
ADJUST
EXIT
DC
FIXED
OFF
ON
AWB
CONTRAST
67
SHARPNESS
16
CB_GAIN
224
CR_GAIN
224
• CONTRAST : The CONTRAST can be adjusted within the value of 0~255 steps.
• SHARPNESS : The outline of the video image becomes cleaner and more distinctive as the level of
SHARPNESS increases. If the level goes up excessively.
However, it may affect the video image and generate noise. (0~31 steps)
• CB_GAIN : Obtains the optimum amount of blue gain. (0~255 steps)
• CR_GAIN : Obtains the optimum amount of red gain. (0~255 steps)
- If the level goes up excessively, It may affect the video image and generate noise.
25
AREA Setting
1
ALL CLEAR
ALL SET
RETURN
1 Cursor : Please select area.
- Yellow color is the selected area.
- Orange color is the nonselected area.
*Press the SETUP switch long. Enter with the sub set menu.
2 All CLEAR : Cancel the all selected area.
3 ALL SET : select all the area.
4 RETURN : Using the ‘RETURN’ key to go back to the main menu.
26
2
3
4
Specification
Model
Signal System
Total/Effective Pixelsg
Pick-Up Device
Lens
Signal Process
Scanning System
Sync. System
Scanning Frequency
Resolution
S/N Ratio
Standard Illuminance
Sensitivity(1/3 output)
Video Output Signal
White Balance
Gain Control
Backlight Compensation
DAY & NIGHT
Electronic Shutter Speed
OSD
Motion Detection
Privacy Mask
Mirror
Power Source
Power Consumption
Operation Temp.
Storage Temp.
Weight
Dimensions
LS300N-D1
LS300P-D1
NTSC
PAL
410K / 380K
470K / 440K
1/3-Inch interline Color CCD (Super HAD)
C/CS Mount
Digital Signal Process
2 : 1 Inerlace
Automatic Internal
59.94 Hz(VD)
50 Hz(VD)
More than 520 TVLine(H)
More than 50dB
2,000Lux (3,200K)
0.4 Lux (F1.0)
1Vp-p Composite (75Ω)
ATW / AWB / Fixed / Manual
ON / OFF
ON / OFF
AUTO / COLOR / BW
AUTO / FIXED(1/60 ~ 1/100,000sec) /
AUTO / FIXED(1/50 ~ 1/100,000sec) /
MANUAL(256 steps) / Flickerless
MANUAL(256 steps) / Flickerless
ON / OFF (64 Area)
ON / OFF (4 Zone)
ON / OFF
DC12V
2.9W
-10℃ ~ +50℃ (Humidity : 0%RH ~ 60%RH)
-20℃ ~ +60℃ (Humidity : 0%RH ~ 85%RH)
Approximately 330g
55(H) x 68(V) x 121.7(D)
27
LS300N-B1
NTSC
410K / 380K
LS300P-B1
LS300P-C1
PAL
PAL
470K / 440K
470K / 440K
1/3-Inch interline Color CCD (Super HAD)
C/CS Mount
Digital Signal Process
2 : 1 Inerlace
Automatic Internal
50 Hz(VD)
59.94 Hz(VD)
50 Hz(VD)
More than 520 TVLine(H)
More than 50dB
2,000Lux (3,200K)
0.4 Lux (F1.0)
1Vp-p Composite (75Ω)
ATW / AWB / Fixed / Manual
ON / OFF
ON / OFF
AUTO / COLOR / BW
AUTO / FIXED(1/50 ~ 1/100,000sec) /
AUTO / FIXED(1/60 ~ 1/100,000sec) /
AUTO / FIXED(1/50 ~ 1/100,000sec) /
MANUAL(256 steps) / Flickerless
MANUAL(256 steps) / Flickerless
MANUAL(256 steps) / Flickerless
ON / OFF (64 Area)
ON / OFF (4 Zone)
ON / OFF
DC12V / AC 24V
AC 230V
2.5W
2.5W
-10℃ ~ +50℃ (Humidity : 0%RH ~ 60%RH)
-20℃ ~ +60℃ (Humidity : 0%RH ~ 85%RH)
Approximately 420g
Approximately 420g
Approximately 500g
55(H) x 68(V) x 121.7(D)
28
P/NO : MFL61949101
Download PDF