- Home
- Domestic appliances
- Climate control
- Split-system air conditioners
- LG
- Heat-pump-Hydrokit-High-Temp
- Installation manual
advertisement
▼
Scroll to page 2
of 51
ENGLISH ITALIANO ESPAÑOL FRANÇAIS INSTALLATION MANUAL DEUTSCH AIR CONDITIONER ΕΛΛΗΝΙΚΆ ČEŠTINA Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly. NEDERLANDS Hydro Kit (For High Temperature) Original instruction POLSKI For more information, Refer to the CD or LG Web site (www.lg.com). www.lg.com P/NO : MFL67798102 LIMBA ROMÂNĂ [Representative] LG Electronics Inc. EU Representative : LG Electronics European Shared Service Center B.V. Krijgsman 1, 1186 DM Amstelveen, The Netherlands [Manufacturer] LG Electronics Inc. Changwon 2nd factory 84, Wanam-ro, Seongsan-gu, Changwon-si, Gyeongsangnam-do, KOREA Hydro Kit Installation Manual TABLE OF CONTENTS 1. SAFETY PRECAUTIONS..............................................................................................................3 2. INSTALLATION PARTS ................................................................................................................8 3. GENERAL INFORMATION ...........................................................................................................9 MODEL INFORMATION ................................................................................................................9 4. INSTALLATION ...........................................................................................................................10 TRANSPORTING THE UNIT.......................................................................................................10 SELECTION OF THE BEST LOCATION .....................................................................................11 INSTALLATION SPACE ...............................................................................................................11 FOUNDATION FOR INSTALLATION...........................................................................................12 WATER PIPING AND WATER CIRCUIT CONNECTION ............................................................13 SANITARY WATER TANK AND SANITARY WATER TANK KIT..................................................16 INSTALLATION SCENES ............................................................................................................18 REFRIGERANT PIPING..............................................................................................................20 HOW TO CONNECT WIRINGS...................................................................................................22 WIRING CONNECTION ..............................................................................................................22 CONNECTING CABLES .............................................................................................................23 5. ACCESSORIES INSTALLATION ................................................................................................24 LOCATION OF ACCESSORIES AND EXTERNAL PARTS CONNECTION................................24 MAIN PUMP CONNECTION .......................................................................................................27 WATER TANK TEMPERATURE SENSOR CONNECTION.........................................................27 THERMOSTAT.............................................................................................................................28 REMOTE TEMPERATURE SENSOR .........................................................................................31 3WAY VALVE ...............................................................................................................................32 DRY CONTACT ...........................................................................................................................34 6. SYSTEM SET-UP ........................................................................................................................35 DIP SWITCH SETTING ...............................................................................................................35 GROUP CONTROL SETTING.....................................................................................................36 INSTALLER SETTING.................................................................................................................40 7. TEST RUN ...................................................................................................................................48 CAUTION BEFORE OPERATION TEST.....................................................................................48 OPERATION TEST OF WATER PIPE .........................................................................................48 TROUBLESHOOTING.................................................................................................................49 2 Hydro Kit Safety Precautions WARNING This symbol indicates the possibility of death or serious injury. CAUTION This symbol indicates the possibility of injury or damage to properties only. ■ Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING ■ Installation For electrical work, Do not use a defective contact the dealer, or underrated circuit breaker. Use this appli- seller, a qualified electrician, or an Authorance on a dedicated ized Service Center. circuit. • There is risk of fire or • There is risk of fire or electric shock. electric shock. Install the panel and the cover of control box securely. • There is risk of fire or electric shock. Always ground the unit. • There is risk of fire or electric shock. Use the correctly rated Always install a dedibreaker or fuse. cated circuit and breaker. • Improper wiring or instal- • There is risk of fire or electric. lation may cause fire or electric shock. Hydro Kit Installation Manual 3 ENGLISH 1. Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Be sure to read before installing the unit. ■ Be sure to observe the cautions specified here as they include important items related to safety. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. Safety Precautions Do not modify or extend the power cable. • There is risk of fire or electric shock. For antifreeze, always contact the dealer or an authorized service center. • There is risk of fire, elec- • Almost the antifreeze is a toxic product. tric shock, explosion, or injury. Do not install, remove, or reinstall the unit by yourself (customer). For installation, always Do not install the unit The refrigerant of this contact the dealer or an on a defective installaunit is R134a and the tion stand. unit is connected to the Authorized Service Center. outdoor unit where R410A refrigerant is used. • The installation tool such • There is risk of fire, elec- • It may cause injury, accident, or damage to the tric shock, explosion, or as manifold gauge unit. injury. should comply with R410A. Be sure the installation Do not install the water Do not install the unit outside. pipe system as Open area does not deterioloop type. rate with age. • It may cause damage to • If the base collapses, the • It may cause failure of the unit. unit. unit could fall with it, causing property damage, unit failure, and personal injury. Use a vacuum pump or inert (nitrogen) gas when doing leakage test or purging air. Do not compress air or oxygen and do not use flammable gases. • There is the risk of death, injury, fire or explosion. 4 Hydro Kit Safety Precautions Do not place anything Take care to ensure that power cable could on the power cable. not be pulled out or damaged during operation. • There is risk of fire or • There is risk of fire or electric shock. electric shock. Do not touch (operate) the unit with wet hands. • There is risk of fire or electric shock. Do not store or use flammable gas or combustibles near the unit. • There is risk of fire or failure of unit. If strange sounds, or small or smoke comes from unit, turn the breaker off or disconnect the power supply cable. • There is risk of electric shock or fire. Do not place a heater or other appliances near the power cable. • There is risk of fire or electric shock. Do not use the unit in a tightly closed space for a long time. • It may cause damage to the unit. Do not plug or unplug the power supply plug during operation. • There is risk of fire or electric shock. Do not allow water to run into electric parts. • There is risk of fire, failure of the unit, or electric shock. When flammable gas leaks, turn off the gas and open a window for ventilation before turning the unit on. • There is risk of explosion or fire. Do not open the front Stop operation and cover of the unit while close the window in operation. (Do not storm or hurricane. If touch the electrostatic possible, remove the filter, if the unit is so unit from the window before the hurricane ar- equipped.) rives. • There is risk of property • There is risk of physical injury, electric shock, or damage, failure of unit, unit failure. or electric shock. Hydro Kit Installation Manual 5 ENGLISH ■ Operation Safety Precautions Ventilate the unit from Be cautious that water When the unit is soaked (flooded or sub- could not be poured to time to time when operating it together with a the unit directly. merged), contact an stove, etc. Authorized Service Center. • There is risk of fire, elec- • There is risk of fire or • There is risk of fire or electric shock. tric shock, or unit damelectric shock. age. Turn the main power off when cleaning or maintaining the unit. • There is risk of electric shock. If the unit is not used for long time, we strongly recommend not to switch off the power supply to the unit. • There is risk of water freezing. 6 Hydro Kit Take care to ensure that nobody could step on or fall onto the unit. • This could result in personal injury and unit damage. For installation, always contact the dealer or an Authorized Service Center. • There is risk of fire, electric shock, explosion, or injury. Safety Precautions ENGLISH CAUTION ■ Installation Keep level even when Always check for gas installing the unit. (refrigerant) leakage after installation or repair of unit. • To avoid vibration or • Low refrigerant levels may cause failure of unit. water leakage. Use two or more people to lift and transport the unit. • Avoid personal injury. ■ Operation Do not step on or put Use a soft cloth to Do not use the unit for special purposes, such clean. Do not use harsh anything on the unit. detergents, solvents, as preserving foods, etc. works of art, etc. • There is risk of damage • There is risk of fire, elec- • There is risk of personal injury and failure of unit. tric shock, or damage to or loss of property. the plastic parts of the unit. Use a firm stool or ladder when cleaning or maintaining the unit. • Be careful and avoid personal injury. Hydro Kit Installation Manual 7 Installation Parts 2. Installation Parts Thank you for choosing LG Electronics Hydro Kit. Before starting installation, please make it sure that all parts are found inside the unit box. Item Image Quantity ENGLISH ITALIANO ESPAÑOL FRANÇAIS INSTALLATION MANUAL AIR CONDITIONER DEUTSCH ΕΛΛΗΝΙΚΆ Installation Manual 1 ČEŠTINA NEDERLANDS Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly. POLSKI Hydro Kit (For High Temperature) Original instruction LIMBA ROMÂNĂ www.lg.com P/NO : MFL67798102 Owner's Manual 1 OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : Hydro Kit (For High Temperature) www.lg.com P/NO : MFL67212703 Remote Controller / Cable Sensor Holder Water Tank Temperature Sensor Strainer 8 Hydro Kit 1 1 1 1 General Information With advanced inverter technology, Hydro Kit is suitable for applications like under floor heating, and hot water generation. By Interfacing to various accessories user can customize the range of the application. Model Information Model name and related information Hydro Kit (For High Temperature) Type Model Unit Power Supply Ø, V, Hz Capacity Heating Net Weight Refrigerant ARNH08GK3A2 kW 25 13.8 kcal/h 21500 11870 Btu/h 85300 47000 kg(lbs) 94(207) Quantity 88(194) R134a Type Noise Level ARNH04GK3A2 1, 220-240, 50 kg(lbs) dB 3(6.61) 2.3(5.07) 43 *1 : Tested under Eurovent Heating condition (Water temperature 55℃(131℉) 65 ℃(149 ℉) at outdoor ambient temperature 7℃(44℉) / 6℃(42℉)) Hydro Kit Installation Manual 9 ENGLISH 3. General Information Installation 4. Installation Transporting the Unit • When carrying the suspended unit, pass the ropes between legs of base panel under the unit. • Always lift the unit with ropes attached at 6 points so that impact is not applied to the unit. • Attach the ropes to the unit at an angle Ⓐ of 40° or less. • Use only accessories and parts which are of the designated specification when installing. Sub line 40º or less Line supporter CAUTION Be very careful while carrying the unit. - Do not have only one person carry the unit if it is more than 20 kg (44.1 lbs). - PP bands are used to pack some products. Do not use them as a mean for transportation because they are dangerous. - Tear plastic packaging bag and scrap it so that children cannot play with it. Otherwise plastic packaging bag may suffocate children to death. - When carrying the unit, be sure to support it at 6-points. Carrying and lifting the unit with 4-point support may make it unstable, resulting in a fall. 10 Hydro Kit Installation ENGLISH Selection of the best location 1. Select space for installing the unit, which will meet the following conditions: • The place where the unit shall be installed inside. • The place shall easily bear a load exceeding four times of the unit weight. • The place where the unit shall be leveled. • The place shall allow easy water drainage. • The place where the unit shall be connected to the outdoor unit. • The place where the unit is not affected by an electrical noise. • The place where there should not be any heat source or steam near the unit. Installation Space • The following values are the least space for installation. If any service area is needed for service according to field circumstance, obtain enough service space. • The unit of values is mm. (Unit: mm) 400 100 520 space Piping space (front side) 330 600 (Unit: mm) 100 100 Anti Vibration material 1080 space 100 Service space (front side) 1080 Service space (left side) H-Beam supporter Concrete supporter 200 300 Hydro Kit Installation Manual 11 Installation Foundation for Installation • Fix the unit tightly with bolts as shown below so that the unit will not fall down due to earthquake. • Noise and vibration may occur from the floor or wall since vibration is transferred through the installation part depending on installation status. Thus, use anti-vibration materials (cushion pad) fully (The base pad shall be more than 200 mm (7-7/8 inch)). 392 12 Hydro Kit (Unit: mm) 75 354 Anti-vibration material Concrete 3 or more screw Nut base threads of the Support 2 bolts must be Spring washer shown Flat washer Anchor bolt Installation General Considerations Followings should be considered before beginning water circuit connection. • Service space should be secured. • Water pipes and connections should be cleaned using water. • Space for installing external water pump should be provided. • Never connect electric power while proceeding water charging. Water Piping and Water Circuit Connection While installing water pipes, followings should be considered : • While inserting or putting water pipes, close the end of the pipe with pipe cap to avoid dust entering. • When cutting or welding the pipe, always be careful that inner section of the pipe should not be defective. For example, no weldments or no burrs are found inside the pipe. • Pipe fittings (e.g. L-shape elbow, T-shape tee, diameter reducer, etc) should be tightened strongly to be free from water leakage. • Connected sections should be leakage-proof treatment by applying tefron tape, rubber bushing, sealant solution, etc. • Appropriate tools and tooling methods should be applied to prevent mechanical breakage of the connections. • Operation time of flow valve(e.g. 3way valve) should be less than 90 seconds. • Pipe is insulated to prevent heat loss to external environment. Hydro Kit Installation Manual 13 ENGLISH Water Piping and Water Circuit Connection Installation Water cycle * For the water pipe system, use the closed loop type. 1. For the parts of the water pipe system, use the parts above the design water pressure. 2. For the water pipe, do not use steel pipe. 3. To replace the connected device easily, install the union joint (2). 4. Install the service port (3) to clean the heat exchanger at each inlet and outlet of the water pipe. 5. Always install a strainer (4) at the inlet of the water pipe. - For the strainer, use one with 50 mesh or above with measurement diameter of 0.4mm or less. (Exclude other net) - Always install the strainer on the horizontal pipe. (When dirt, trash, rusted pieces get into the water pipe system, it can cause problems to the product by corroding the metallic material.) 6. Install the air vent (5) at the top of the water pipe. 7. Install a thermometer (6) and pressure gauge (7) at the inlet and outlet of the water pipe. 8. Install the drain valve (8) that can be used for draining the water inside when replacing the part or providing service. 9. Install the shut-off valve (9) to block the water by closing the valve when replacing the part or cleaning. 10. Apply insulated treatment on the exterior of the water pipe so that water drops do not form. 11. Install excessive pressure safety valve (10) that meets the design water pressure to prevent unit or water pipe damage at the pressure increase inside the water pipe system. Hydro kit (For High Temperature) On-site installation (1) Air vent (5) Union joint (2) Pressure gauge(7) Thermometer (6) Shut-off valve (9) Excessive pressure safety valve(10) Outlet Water [Install water tank] or [Install floor heating] Inlet water P/T Service port(3) Strainer(4) Drain valve(8) 12. There is a drain hole at the bottom of the Hydro Kit to prevent risk of electric shock caused by leakage of water. 14 Hydro Kit Installation 1. Use the pump (1) with sufficient capacity to assure loss of overall water pressure and to supply water to the Hydro Kit. 2. Install the shut-off valve (2) on both sides of the pump to clean and repair the pump. 3. Install the flexible joint (3) to prevent noise and vibration transferred from the pump. 4. Install the pressure gauge (4) to monitor the water pressure from water tank. (Option) 5. Install the expansion tank (5) to accommodate the water contracted or expanded from the temperature difference and to supply the water. 6. After the installation of water pipe system is completed, open the water supply valve (6) and supply the water. 7. When installing the water tank, insert the water tank temperature sensor (7) to measure the temperature of the water inside the tank. - For the water tank temperature sensor, use the sensor supplied on the product. - When heating the floor, measure the temperature by using the remote controller or remote temperature sensor (Separately sold). 8. Use the water tank (9) with the heat exchange coil (8) installed so that the heat can be exchanged sufficiently inside the tank. Installation of water tank water tank temperature sensor (7) shut-off valve (2) Pump (1) Flexible joint (3) Expansion tank (5) Heat exchange coil (8) water tank (9) (Indirect heating type) Water supply valve (6) Pressure gauge (4) Installation of floor heating shut-off valve (2) Pump (1) Flexible joint (3) Expansion tank (5) Floor heating coil (Radiator, FCU can be used) Water supply valve (6) Pressure gauge (4) Hydro Kit Installation Manual 15 ENGLISH * Water tank & Floor heating installation Installation Strainer - Use the 50 mesh strainer. (Exclude scale diameter of 0.4mm or less and other net) - Check the strainer direction and assemble on the inlet hole (Refer to picture) - Wrap the Teflon tape on the screw thread of the water pipe for more than 15 times for assembly. - Install the service port facing downward. (Within left/right 45 degrees) - Check if there is any leakage on the connecting part. - Clean the strainer periodically. (Once a year or more frequent) Water In 45° Front Strainer Side Sanitary Water Tank and Sanitary Water Tank Kit Installation Condition Installing sanitary water tank requires following considerations : • Sanitary water tank should be located at the flat place. • Water quality should comply with EN 98/83 EC Directives. • As this water tank is sanitary water tank (indirect heat exchange), do not use anti water-freezing treatment like ethylene grycol. • It is highly recommend to wash out inside of the sanitary water tank after installation. It ensures generating clean hot water. • Near the sanitary water tank, there should be water supply and water drain for easy access and maintenance. Water Tank Temperature Sensor Water Out Water In Sanitary Water Tank 16 Hydro Kit Installation • If hot water mode is used, make sure to install sensor to water tank. • Make PT15A female bolt hole in the water tank, and install sensor in the water tank. Process PT 1/2 inch female bolt Sensor Water Tank Temperature Sensor holder Inside water tank • Push the sensor into the hole of the sensor holder cap. • Lock the sensor holder cap. PT 1/2 inch Water tank outer wall WARNING : Installing recirculation pump When Hydro Kit is used with the sanitary water tank, it is STRONGLY recommended to install recirculation pump to prevent cold water at the end of hot water supply flooding out and to stabilize the water temperature inside the sanitary water tank. - The recirculation pump should be operated when sanitary water demand is not required. Therefore, external time scheduler to determine when the recirculation pump should turn on and turn off is required. - The operating duration time of the recirculation pump is calculated as follow : Duration time [minute] = k * V / R k : 1.2 ~ 1.5 is recommended. (If distance between pump and tank is far, then choose high number.) V : Volume of sanitary water tank [liter] R : Water flow rate of pump [liter per minute], which is determined by pump performance curve. - The pump operating start time should be prior to the sanitary water demand. Hot water supply Shower (End of Hot water supply) Recirculation Pump Water Out External Time Scheduler Water In City water Sanitary Water Tank Hydro Kit Installation Manual 17 ENGLISH Water tank temperature sensor connection Installation Installation Scenes Some installation scenes are presented for example. As these scenes are conceptual figures, installer should optimize the installation scene according to the installation conditions. 1) Floor Heating only (Without mixing tank) Fan coil unit Floor heating loop Radiator 2) Floor Heating only (With mixing tank) Fan coil unit Floor heating loop Radiator Fan coil unit Floor heating loop Radiator 3) Floor Heating + Hot water Hot water Sanitary water tank City water 4) Hot water only Pump 3way valve Bypass valve Hot water City water 18 Hydro Kit Sanitary water tank Installation Water quality should comply with EN 98/83 EC Directives. Requirement for resolved chemical ingredients is following table. Detailed water quality condition can be found in EN 98/83 EC Directives. Parameter Acrylamide Antimony Arsenic Benzene Benzo(a)pyrene Boron Bromate Cadmium Chromium Copper Cyanide 1.2-dichloroethane Epichlorohydrin Value 0.10 μg/l 5.0 μg/l 10 μg/l 1.0 μg/l 0.010 μg/l 1.0 mg/l 10 μg/l 5.0 μg/l 50 μg/l 2.0 mg/l 50 μg/l 3.0 μg/l 0.10 μg/l Parameter Value Fluoride 1.5 mg/l Lead 10 μg/l Mercury 1.0 μg/l Nickel 20 μg/l Nitrate 50 mg/l Nitrite 0.50 mg/l Pesticides 0.10 μg/l Pesticides — Total 0.50 μg/l Polycyclic aromatic hydrocarbons 0.10 μg/l Selenium 10 μg/l Tetrachloroethene and Trichloroethene 10 μg/l Trihalomethanes — Total 100 μg/l Vinyl chloride 0.50 μg/l CAUTION • If the unit is installed at existing hydraulic water loop, it is important to clean hydraulic pipes to remove sludge and scale. • Installing sludge strainer in the water loop is very important to prevent performance degrade. • Chemical treatment to prevent rust should be performed by installer. Frost protection In areas of the country where entering water temperatures drop below 0℃(32℉), the water pipe must be protected by using an approved antifreeze solution. Consult your Hydro Kit unit supplier for locally approved solutions in your area. Calculate the approximate volume of water in the system. (Except the Hydro Kit unit.) And add antifreeze solution to the total volume to allow for the water contained in Hydro Kit unit. Type of Antifreeze Ethylene glycol Propylene glycol Methanol Minimum Temperature for Freeze Protection 0℃(32℉) 0% 0% 0% -5℃(23℉) 12% 17% 6% -10℃(14℉) 20% 25% 12% -15℃(5℉) 30% 33% 16% -20℃(-4℉) -25℃(-13℉) 24% 30% CAUTION 1. Use only one of the above antifreeze. 2. If a antifreeze is used, pressure drop and capability degradation of the system can occur. 3. If one of antifreezes is used, corrosion can occur. So please add corrosion inhibitor. 4. Please check the concentration of the antifreeze periodically to keep same concentration. 5. When the antifreeze is used (for installation or operation), take care to ensure that antifreeze must not be touched. 6. Ensure to respect all laws and norms of your country about Anti-freeze usage. 7. When hydro kit is applied for heating, the antifreeze never added in the water circuit. Hydro Kit Installation Manual 19 ENGLISH Water Quality Installation Refrigerant Piping Cut the pipes and the cable - Use the accessory piping kit or the pipes purchased locally. - Measure the distance between the indoor and the outdoor unit. - Cut the pipes a little longer than measured distance. - Cut the cable 1.5m longer than the pipe length. Copper tube Slanted Uneven Rough 90° Pipe Reamer Burrs removal - Completely remove all burrs from the cut cross section of pipe/tube. - Put the end of the copper tube/pipe to downward direction as you remove burrs in order to avoid to let burrs drop in the tubing. Point down Pipe welding - Insert and weld the pipe. - Always make sure to flow Nitrogen at 0.2kgf/cm2 within the pipe when welding. - If the welding is done without flowing Nitrogen, it can generate a thick oxidized coating within the pipe to interfere with normal operation of valve and compressor etc. Direction of Nitrogen Regulator Copper tube Taping Valve Nitrogen Insulation - Use rubber foamed insulation material (EPDM, NBR) with high thermal resistance. - When installed in humid environment, use thicker insulation material than usual. - Insert the insulation material within the product as deep as possible. Classification Thickness Gas pipe(Ø15.88 – 4HP) (Ø22.2 - 8HP) t19 above Inside product Panel Insulation Copper tube ❈ The thickness of the above insulation material is based on thermal conduction rate of 0.036W/m°C. CAUTION There is no pump-down function because Hydro Kit is the only heating unit. After vacuum drying, recharge the refrigerant. 20 Hydro Kit Installation Gas pipe Ø15.88 Liquid pipe Ø9.52 Welding type Recaution when connecting to synchronous type outdoor unit - One connection of refrigerant pipe for HR unit is insufficient for the flow of refrigerant. Join two pipes with a branch pipe when connecting the Hydro Kit (Up to 16kW (54kBut/h) capacity model: ARNH08GK3A2). - The pipe number of the connected gas pipe and liquid pipe must be same. Hydro kit Flow water in the Hydro Kit when pipe-searchGas pipe Ø22.2 Liquid pipe Ø9.52 ing process is performed. - Pipe-searching process error may occur if the pipe temperature does not increase. - It is recommended that Hydro Kit is connected to No.1 valve and No.2 valve. DIP S/W setting Example 4 3 2 1 Indoor Unit Indoor Unit Indoor Unit Indoor Unit 4 3 2 1 Indoor Unit Indoor Unit Hydro kit No.2, 3 Valve Control 4 3 2 1 Indoor Unit Hydro kit Indoor Unit No.3, 4 Valve Control 4 3 2 1 Hydro kit Indoor Unit Indoor Unit Not control No.1, 2 Valve Control No.1, 2 Valve / No.3, 4 Valve Control 4 3 2 1 Hydro kit Hydro kit (When two Hydro Kit are installed) Pipe searching process 1. When Pipe searching process is performed, - Use ‘Mode 1’ if water temperature is higher than 30℃(86℉) - Use ‘Mode 2’ if water temperature is lower than 30℃(86℉) 2. When Pipe searching process is not performed, - Check whether ‘CH14’ error occurs in the Hydro Kit. *Refer to the installation manual of HR unit Hydro Kit Installation Manual 21 ENGLISH Precaution when connecting Heat Recovery systems Installation How to connect wirings Remove the box cover of electric parts and connect the wiring CAUTION Communication cable Communication cable When connecting the power and communication cable, always use the terminal connector (Oring, Y-ring). Power cable Power cable ARNH08GK3A2 ARNH04GK3A2 Make sure to tighten so that the screw of the terminal does not get loose. Wiring Connection Connect the wires to the terminals on the control board individually according to the outdoor unit connection. *Ensure that the wire color of the outdoor unit and terminal No. are same as those of the indoor unit respectively. Terminal block of indoor unit Power cable Earth Terminal block Terminal block of outdoor unit of indoor unit DRY1 DRY2 3(A) 4(B) Outdoor unit Indoor unit Communication cable WARNING : Make sure that the screws of the terminal are free from looseness. CAUTION After checking the above status, prepare for the following wiring : 1) Use individual power for the unit and refer to the circuit diagram posted on the inside of the control cover. 2) Make sure to install 30A capacity circuit breaker when power is connected to the unit. 3) The bolts used for cable connection may become loose by the vibration generated during the transportation. Make sure to check again and fasten them tightly. (If they are loose, it may cause fire.) 4) Make sure to check power specification. 5) Electrical capacity shall be sufficient. 6) The initial voltage shall be maintained at 90% of the rated voltage on the name plate. 7) The thickness of the power cable complies with the designated specification. (length and thickness of the power cable) 8) Do not install the circuit breaker in the place where there is a lot of moisture or where it is wet. 9) The following problems may be the cause of voltage drop. - Magnetic switch vibration, defective contact, fuse damage, malfunction of overload protection device ❈ Based on the owner’s manual, teach how to operate and use the unit to the user. (temperature setting, etc.) 22 Hydro Kit Installation ENGLISH Connecting Cables Types of the cables Classification types Cable cross section Power cable(CV) mm x cores 4.0 x 3 Communication cable(VCTF-SB) mm2 x cores 1.0~1.5 x 2 2 The distance between communication cable and power cable - If the power cable and communication cable are tied together, system malfunction may occur with electrostatic, electromagnetic combination effect causing the interference signal. If communication cable is connected along with power cable, secure at least 50mm distance between indoor unit power cable and communication cable. is the value with assumption of the length of the parallel cable It isIt the value with thethe assumption of the length of the parallel cable as as 100100 m. m. If it is longthan 00m, If it isbelonger than 100m, it shall be calculated again withlength. proportional to the added length. it shall calculated again with proportional to the added If the distance is secured as the previous page, still andoccurs the distortion the waveform of the power still If the distortion in the waveform of the power despiteinsecuring the distance, increase occurs, increase the distance. the distance. ※ When several power cables areare inserted intointo thethe transmission line, or or tiedtied together, make sure to ※ When several power cables inserted transmission line, together, make sure consider the following issues. to consider the following issues. - Power cables and communication lines shall not be in the same transmission line. Powercables cablesand andcommunication communicationlines cableshall shallnot notbebetied in the same transmission line. --Power together. - Power cables and communication cable shall not be tied together. WARNING • Are all of the indoor units and outdoor units grounded? • If grounding is not properly done, there is a risk of electric shock. Grounding must be done by a qualified technician. • Consider the surrounding conditions(surrounding temperature, direct sunlight, rain water, etc.) when wiring the cable. • The thickness of the power cable is the minimum thickness of metal conductor cable. Use thicker cable considering the voltage drop. Hydro Kit Installation Manual 23 Accessories Installation 5. Accessories Installation Location of Accessories and External Parts Connection Dry contact board attachment location Dry contact board locking location (CN-CC) Remote controller locking location (CN-REMO) Water tank temperature sensor locking location (CN-TH4) L N PUMP (A) L L1 N 3WAY VALVE (A) L N L1 L2 THERMOSTAT (Default : 230V AC) • Connect 3way valve, if both floor heating and hot water is used. • Connect the separately purchased thermostat. • Dry contact is an accessory supplied by LG and installed by referring to the attached installation manual. • 3way valve, thermostat and pump are external parts for installation, which are not supplied by LG. After checking each part carefully, install external parts respectively. • Connect the cable of each accessory to the terminal block of the control box in the Hydro Kit. • Check the label attached on the terminal block to prevent wrong connection. • Use the pump of 220-240 voltage and maximum operation current of 4A or less. • Select a suitable relay for pump capacity when connecting the pump to the unit. WARNING: • Install the unit after turning off the main power. • Do not connect the products out of range specified in the manual. • Do not work with wet hand. 24 Hydro Kit Accessories Installation ENGLISH Installation of Wired Remote Controller 1. Please fix tightly using provided screw after placing remote controller setup board on the place where you like to setup. - Please set it up not to bend because poor setup could take place if setup board bends. Please set up remote controller board fit to the reclamation box if there is a reclamation box. 2. Can set up Wired remote controller cable into three directions. - Setup direction: the surface of wall reclamation, upper, right - If setting up remote controller cable into upper and right side, please set up after removing remote controller cable guide groove. 2 2 3 ❈ Remove guide groove with long nose. ① Reclamation to the surface of the wall ② Upper part guide groove ③ Right part guide groove 3. Please fix remote controller upper part into the setup board attached to the surface of the wall, as the picture below, and then, connect with setup board by pressing lower part. - Please connect not to make a gap at the remote controller and setup board’s upper and lower, right and left part. 3 1 <Wire guide grooves> <Connecting order> Wall Side Wall Side <Separating order> When separating remote controller from setup board, as the picture below, after inserting into the lower separating hole using screw driver and then, spinning clockwise, remote controller is separated. - There are two separating holes. Please individually separate one at a time. - Please be careful not to damage the inside components when separating. Wall Side Wall Side Hydro Kit Installation Manual 25 Accessories Installation 4. Please connect indoor unit and remote controller using connection cable. Male plug ends Please check if connector is normally connected. Hydro Kit Female plug ends Optional extension cable (purchased separately) 5. Please use extension cable if the distance between wired remote controller and indoor unit is more than 10m. Extension cable(10m) model name : PZCWRC1 CAUTION When installing the wired remote controller, do not bury it in the wall. (It can cause damage in the temperature sensor.) Do not install the cable to be 50m or above. (It can cause communication error.) • When installing the extension cable, check the connecting direction of the connector of the remote controller side and the product side for correct installation. • If you install the extension cable in the opposite direction, the connector will not be connected. • Specification of extension cable: 2547 1007 22# 2 core 3 shield 5 or above. 26 Hydro Kit Accessories Installation • Select the suitable pump by referring to the flow rate table with water temperature difference between the entrance and the exit. *It is recommended that the flow rate is 36LPM. Pump (main) 1 2 L N • Use the pump with enough capacity to guarantee the loss of entire water pressure and to supply the Hydro Kit with water. • Select a suitable relay for pump capacity when connecting the pump to the unit. Relay • Connect the relay to the terminal block 11 and 12 of the control box. Pump CAUTION • Make sure to supply external power with the pump. Water tank temperature sensor Connection • Connect sensor housing to PCB‘CN-TH4’ connector (red). CN-TH4 Housing Water tank thermistor CAUTION • If water tank temperature sensor is not connected, error will occur. (CH08) Exclude the case of using floor heating. Hydro Kit Installation Manual 27 ENGLISH Main Pump Connection Accessories Installation Thermostat Thermostat is generally used to control the unit by air temperature. When thermostat is connected to the unit, the unit operation is controlled by the thermostat. Installation Condition CAUTION 1. USE 1~230 V Thermostat. 2. Some electro-mechanical type thermostat has internal delay time to protect compressor. In that case, mode change can takes time more than user's expectation. Please read thermostat manual carefully if the unit does not response quickly. 3. Setting temperature range by thermostat can be different with that of the unit. The heating set temperature should be chosen within the setting temperature range of the unit. 4. It is highly recommended that the thermostat should be installed where space heating is mainly applied. Following location should be avoid to secure proper operation : • Height from floor is approximately 1.5 m. • Thermostat can not be located where the area may be hidden when door is open. • Thermostat can not be located where external thermal influence may be applied. (such as above heating radiator or open window) Direct Sun ray contact area yes no no 1.5 m no 28 Hydro Kit Accessories Installation Hydro Kit supports following thermostats. Type Power Mechanical (1) 1~ 230 V Heating Only (3) Operating Mode Supported Yes Electrical (2) 1~ 230 V Heating Only (3) Yes (1) There is no electric circuit inside the thermostat and electric power supply to the thermostat is not required. (2) Electric circuit such as display, LED, buzzer, etc is included in the thermostat and electric power supply is required. (3) Thermostat generates "Heating ON or Heating OFF" signal according to user"s heating target temperature. How to Wire Thermostat Follow below procedures Step 1 ~ Step 4. Step 1. Uncover front cover of the unit and open the control box. Step 2. Identify the power specification of the thermostat. 1~230V thermostat is used in the Hydro Kit (For High Temperature). Step 3. If it is Heating Only Thermostat, go to step 4. Step 4. Find terminal block and connect wire as below. THERMOSTAT (Default : 1~ 230 V) 7 L BR (L) 8 9 N L1 BL WH (N) Thermostat 10 L2 BK (H) WARNING : Mechanical type Thermostat. Do not connect wire (N) as mechanical type thermostat does not require electric power supply. CAUTION Do not connect external electric loads. Wire (L) and (N) should be used only for operation Electric type thermostat. Never connect external electric loads such as valves, fan coil units, etc. If connected, Main PCB Assembly 1 can be seriously damaged. (L) : Live signal from PCB to Thermostat (N) : Neutral signal from PCB to Thermostat (H) : Heating signal from Thermostat to PCB Hydro Kit Installation Manual 29 ENGLISH General Information Accessories Installation Final Check • DIP switch setting : Set DIP switch No. 8 to ‘ON’. Otherwise, the unit can not recognize the thermostat. • Remote Controller : - ‘Thermostat’ icon is displayed on the remote controller. - Button input is prohibited. Thermostat Icon NOTICE ?)<-: 0-)<16/ 78-:Thermostat Operation with Remote Controller 57,-Following features are permitted when thermostat is installed : 78-: 57,- : / • SET TEMP button <-58 <-58 ?)<-: 0-)<16/• 78-: 57,- • <-58 • ?)<-: 0-)<16/ VIEW TEMP button Temperature adjusting button(*) 78-: Sanitary water heating button 57,- (*) : The unit is not turned on/off according to the setting temperature at the remote controller. <-58 It is turned on/off according to the thermostat signal. 78-: 57,- <-58 Following features are NOT permitted when thermostat is installed : ?)<-: 0-)<16/• 78-: 57,- • Operating mode (heating/ weather-dependent) selection Time scheduling <-58 ?)<-: 0-)<16/ 78-:• 57,- Operation On / Off Sequence of thermostat operation <-58 - How to set the heating temperature when thermostat is connected to the Hydro Kit. Set thermostat to the heating mode 30 Hydro Kit Adjust the heating temperature, using the remote controller Accessories Installation Remote temperature sensor can be installed any place a user wants to detect the temperature. How to Install Remote Temperature Sensor Step 1. After deciding where the remote temperature sensor is installed, decide the location and height of the fixing screws. (Interval between the screws : 60mm) Step 2. Insert the connector of the connection wire into the space for the connector in place of the room temperature sensor.(CN_ROOM) Fixing screws 60mm Step 3. Separately, set the option code of the attached controller on the indoor unit. In detail, refer to "installer setting mode". Step 4. The Connection wire does not matter if you change the color of the wire because of nonpolar. Step 5. Integrate the remote temperature sensor with the screws as the order of arrows. Fixing the Remote Sensor 1 2 CAUTION 1. Choose the place where the average temperature can be measured for the indoor unit operates. 2. Avoid direct sunlight. 3. Choose the place where the heating devices do not affect the remote sensor. 4. Choose the place where the outlet of the cooling fan do not affect the remote sensor. 5. Choose the place where the remote sensor isn't affected when door is open. Hydro Kit Installation Manual 31 ENGLISH Remote Temperature Sensor Accessories Installation 3Way Valve 3way valve is required to operate sanitary water tank. Role of 3way valve is flow switching between under floor heating loop and water tank heating loop. General Information Hydro Kit supports following 3way valve. Type SPDT 3-wire (1) Power Operating Mode 1~ 230 V Selecting “Flow A” between “Flow A” and “Flow B” (2) Selecting “Flow B” between “Flow A” and “Flow B” (3) Supported Yes Yes (1) SPDT = Single Pole Double Throw. Three wires consist of Live (for selecting Flow A), Live 1 (for selecting Flow B), and Neutral (for common). (2) Flow A means ‘water flow from the unit to sanitary water tank’ (3) Flow B means ‘water flow from the unit to under floor water circuit’ How to Wire 3Way Valve Follow below procedures Step 1 ~ Step 2. Step 1. Uncover front cover of the unit and open the control box. Step 2. Find terminal block and connect wire as below. 3WAY VALVE (A) 4 5 6 L L1 N BR WH BL (W) (U) (N) WARNING : • 3way valve should select water tank loop when electric power is supplied to wire (W) and wire (N). • 3way valve should select under floor loop when electric power is supplied to wire (U) and wire (N). 3way valve (W) : Live signal (Water tank heating) from PCB to 3way valve (U) : Live signal (Under floor heating) from PCB to 3way valve (N) : Neutral signal from PCB to 3way valve WARNING : Mice can not be appeared to prevent entering the unit or attacking wires. 32 Hydro Kit Accessories Installation • Flow direction : - Water should flow from water outlet of the unit to sanitary tank water inlet when sanitary tank heating is selected. - To verify the flow direction, check temperature at the water outlet of the unit and water inlet of sanitary water tank. - If correctly wired, these temperatures should be almost equivalent if thermal insulation of water pipe is well performed. • Noise or water pipe vibration while 3way valve operation - Due to surging effect or cavitation effect, noise or water pipe vibration can be occurred while 3way valve is operating. - In that case, check followings : • Is water circuit (both under floor water loop and sanitary water tank loop) fully charged? If not, additional water charging is required. • Fast valve operation yields noise and vibration. Appropriated valve operating time is 60~90 seconds. Hydro Kit Installation Manual 33 ENGLISH Final Check Accessories Installation Dry Contact LG Dry Contact is a solution for automatic control of HVAC system at the owner's best. In simple words, it's a switch which can be used to turn the unit On/Off after getting the signal from external sources like key-in lock, door or window switch etc specially used in Hotel rooms. How to Install Dry Contact Connect CN_DRY with Control Unit. - To apply power source through Dry Contact PCB. DRY CONTACT PCB Operation Display CN-CC RY2 RY1 4 3 2 1 4 3 2 1 CN_DRY N Error Check Display Dry contact Controller L 2 2 1 1 INPUT LG does not supply this section 220 - 240V - To apply power source directly to external source. DRY DRY CONTACT CONTACT PCB PCB (unit : mm) CN-CC RY2 RY1 4 3 2 1 CN_DRY 4 3 2 1 Operation Display Error Check Display Dry contact Controller L N 2 1 2 1 220 - 240V LG does not supply this section 34 Hydro Kit System Set-Up As Hydro Kit (For High Temperature) is designed to satisfy various installation environment, it is important to set up system correctly. If not configured correctly, improper operation or degrade of performance can be expected. DIP Switch Setting • Turn off electric power supply before setting DIP switch, There is risk of electric shock. • Dip switch is turned on when pulled right. • Always set dip switch #6 to ON and #7 to OFF. • Do not set dip switch #2 to ON and #3 to OFF. • If dip switch is not set as below, the unit may not operate properly. x : OFF ●: On Description Group Control Dip switch setting Function Default x Master ○ ● Slave 1 2 x Installation Scene Emergency operation Water pump control Thermostat connection 3 4 5 6 7 8 x Floor heating only x ● Floor heating + Hot water ● ● Hot water only x High temperature operation ● Low temperature operation ○ ○ x Water pump controlled with Hydro Kit ● Water pump NOT controlled with Hydro Kit ○ x Thermostat NOT installed ○ ● Thermostat installed Hydro Kit Installation Manual 35 ENGLISH 6. System Set-Up System Set-Up Group Control Setting Group Control - Wired remote controller 1 + Many of Hydro Kit Slave Master Display Error Message Slave Slave Only connect serial signal and GND lines between slave indoor unit GND Signal 12 V Master - Dip Switch in PCB ¿ Master Setting - No. 1 Off ¡ Slave Setting - No. 1 On 1. It is possible to connect 16 indoor units(Max) by one wired remote controller. Set only one indoor unit to Master, set the others to Slave. 2. You can connect all the types of 2nd generation indoor units . 3. It is possible to use wireless remote controller at the same time. 4. It is possible to connect Dry Contact and Central controller at the same time. - The Master indoor unit is possible to recognize Dry Contact and Central Controller only. - In case of Central controller and Group controller at the same time, it is possible to connect standard 2series indoor units or later since Sep. 2012. - In case of Central controller setting, the Central controller can control indoor units after setting only the address of master indoor unit. - Slave indoor unit will be operated like master indoor unit. - Slave indoor unit can not be individually controlled by Central controller. - Some remote controller can’t perform with Dry Contact and Central controller at the same time. So contact us further information about it. 36 Hydro Kit System Set-Up • Indoor unit(Hydro Kit)’s group setting is possible which connected same outdoor unit. • To install Master and Slave indoor unit, the Dip Switch setting should be same. • Group control is not possible between hydro kit and air conditioner. • Group control is not possible between mid temperature hydro kit and high temperature hydro kit. 5. In case that the indoor unit has an abnormal problem an error code will be displayed on the wired remote controller. With the exception of the indoor unit with the error, you can control each indoor unit individually. 6. In case of Group Control, it is possible to use following functions. - Selection of operation options (operation/stop/mode/set temperature) - It is not possible at some functions. h Master/Slave setting of indoor units be set possible using a PCB Dip Switch. h It can be the cause of malfuctions when there is no setting of master and slave. Accessories for group control setting - Accessories for group control setting Indoor unit 2 EA +Wired remote controller ❈ PZCWRCG3 cable used for connection Slave Master PZCWRCG3 Master Hydro Kit Installation Manual 37 ENGLISH CAUTION System Set-Up NOTICE Emergency Operation • Definition of terms - Trouble : a problem which can stop system operation, and can be resumed temporally under limited operation without certificated professional's assist. - Error : problem which can stop system operation, and can be resumed ONLY after certificated professional's check. - Emergency mode : temporary heating operation while system met Trouble. • Objective of introducing 'Trouble' - Not like airconditioning unit, Hydro Kit is generally operated in whole winter season without any system stopping. - If system found some problem, which is not critical to system operating for yielding heating energy, the system can temporarily continue in emergency mode operation with end user's decision. • Classified Trouble - Trouble is classified two levels according to the seriousness of the problem : Slight Trouble and Heavy trouble - Slight Trouble : Sensor trouble. - Heavy trouble : Compressor cycle trouble. - Option Trouble : a problem is found for option operation such as water tank heating. In this trouble, the troubled option is assumed as if it is not installed at the system. • Emergency operation level - When the system is faced with trouble, it stops and waits for user’s decision. : Calling service center or starting emergency operation. - To start emergency operation, user simply push ON / OFF button once more. - Two different levels are prepared for emergency operation : High temperature cycle and low temperature cycle. - In emergency operation mode, user can not adjust target temperature. High temperature cycle Low temperature cycle 38 Hydro Kit DIP Switch (No. 4) Target Leaving Water Temperature Target Room Air Temperature Target Sanitary Water Temperature OFF 70℃(158℉) 24℃(75℉) 70℃(158℉) ON 50℃(122℉) 19℃(66℉) 50℃(122℉) System Set-Up 0-)<16/ 78-: 57,- ?)<-: 0-)<16/ -58 - ENGLISH • Following features are permitted in emergency operation : 8-: 7,?)<-: Operation On/Off 78-: 57,- VIEW TEMP button(*) <-58 - <-58 - ?)<-: 0-)<16/ Temperature adjusting button(**) 78-: Sanitary water heating button 57,- (*) : Temperature measured by failed sensor is displayed as ‘- -’. <-58 (**) : The unit is not turned on/off according to the setting temperature at the remote controller. It is turned on/off according to the thermostat signal. 78-: 57,- <-58 )<-: )<16/ • Following features are NOT permitted in emergency operation : ?)<-: 0-)<16/ 78-: 57,- 78-: 57,-- Operating mode (heating/ weather-dependent) selection Time scheduling <-58 - SET TEMP button <-58 • Duplicated trouble : Option trouble with Slight or Heavy trouble If option trouble is occurred with slight (or heavy) trouble at the same time, the system puts higher priority to slight (or heavy) trouble and operates as if slight (or heavy) trouble is occurred. Therefore, sometimes sanitary water heating can be impossible in emergency operation mode. When sanitary water is not warming up while emergency operation, please check whether the sanitary water sensor and related wiring are connected well or not. • Emergency operation is not automatically restarted after main electricity power is reset. In normal condition, the unit operating information is restored and automatically restarted after main electricity power is reset. But in emergency operation, automatic re-start is prohibited to protect the unit. Therefore, user must restart the unit after power reset when emergency operation has been running. Hydro Kit Installation Manual 39 System Set-Up Installer Setting How to enter installer setting mode CAUTION Installer setting mode is to set the detail function of the remote controller. If the installer setting mode is not set correctly, it could cause problems to the unit, user injury or property damage. This must be set by an certificated installer, and any installation or change that is carried out by a non-certificated person should be responsible for the results. In this case, free service cannot be provided. Function Setting button for 3 seconds 1 Press to enter the installer setting mode. ?)<-: 0-)<16/ <-58 78-: 57,- Function Code Value (When you enter the installer setting mode initially, function code is displayed on the bottom of the LCD screen.) Repeat pressing button, and the function code will be changed. Please refer the code table on the next page. 40 Hydro Kit System Set-Up ENGLISH Summary Example of Fuction Code Display Function Code Function Value #1 Default Value #2 Value #1 Value #2 Disable 3 Min. Delay 02:01 01 - Remote Air Sensor Connection 03:01 01 : NOT connected. 02 : connected. - 04:01 01 : Celsius 02 : Fahrenheit - Setting Temp. Selection 05:02 01 : Air Temp. 02 : Leaving water Temp. - Auto Dry Contact 06:01 01 : Auto Start OFF 02 : Auto Start ON - Celsius/Fahrenheit Switching Remark Address Setting 07:00 00 ~ FF Override Setting 08:00 00 : Slave 01 : Master - Water Pump Test Run 09:00 01 : Set - Setting Air Temp. (Heating Mode) 13:030:016 24℃(75℉) ~ 30℃(86℉) : Upper Limit of setting range 16℃(60℉) ~ 22℃(71℉) : Lower Limit of setting range Setting Leaving Waer Temp. (Heating Mode) 14:080:046 50℃(122℉) ~ 80℃(176℉) : Upper Limit of setting range 30℃(86℉) ~ 46℃(114℉) : Lower Limit of setting range Setting Sanitary Tank Water Temp. (Sanitary Water Heating) 15:080:046 50℃(122℉) ~ 80℃(176℉) : Upper Limit of setting range 00 : Off 01 : On 30℃(86℉) ~ 46℃(114℉) : Lower Limit of setting range Operation mode lock 17:00 Setting outdoor Temp. range (Weather-dependent operation) 23:-10:015 10℃(50℉) ~ 20℃(68℉) : Upper Limit of setting range -20℃(-4℉) ~ 05℃(41℉) : Lower Limit of setting range Setting indoor air Temp. range (Weather-dependent operation) 24:021:016 20℃(68℉) ~ 30℃(86℉) : Upper Limit of setting range 16℃(60℉) ~ 19℃(66℉) : Lower Limit of setting range Setting leaving water Temp. (Weather-dependent operation) 25:080:046 65℃(149℉) ~ 80℃(176℉) : Upper Limit of setting range 40℃(104℉) ~ 54℃(129℉) : Lower Limit of setting range 26:000 00 : Disable 01 : Enable - 26:006:023 01~07 : Starting Date (01:Sun, 02:Mon, ····, 07:Sat) 00~23 hours : Starting Time in 24 hours Setting Temp. (Disinfection Operation) 27:070:010 40℃(104℉) ~ 70℃(129℉)70 : Maximum heating Temp. 05~60 min : Maximum heating duration Setting control parameter (Sanitary water heating operation) 29:003:000 Setting sanitary water heating timers 2b:030 2b:180:020 5 ~ 95 min (step: 5 min) 0 ~ 600 min (step: 30 min) 20 ~ 95 min (step: 5 min) 2E:00 00~03 : Refer to 45p - Setting start/maintain time (Disinfection Operation) Changing thermal on/off room air Temp. 00~01 :Refer to 46p Changing thermal on/off leaving water Temp. 2F:00 00~03 : Refer to 45p - Program version Changing thermal on/off sanitary tank water Temp. 30:00 33:00 Display Version number 00~03 : Refer to 47p - 00 : Based on leaving water Temp 01 : Based on entering water Temp - 37:000:001 000: Operates according to OFF time setting 001 : Pump always on 001 ~ 060 : OFF Time (minutes) Forced product operation 39:00 00 : Forced product operation in use 01 : Forced product operation not in use Dry Contact installation set 41:00 00 : Dry Contact equipped decided on 01 : Dry Contact not installed 02 : Dry Contact installed Select entering/leaving water Temp mode 34:00 in Heating Mode Water Pump operation/delay time set in Heating Mode *Temp. = Temperature Hydro Kit Installation Manual 41 System Set-Up Common Setting • Function Code 02 : Disable 3 minute Delay Only used for an inspection in a factory. • Function Code 03 : Remote Air Sensor Connection If remote air sensor is connected to control the unit by room air temperature, the connection information should be notified to the unit. Note : If remote air sensor is connected but this function code is not set correctly, the unit can not be controlled by room air temperature. • Function Code 04 : Celsius/Fahrenheit Switching Temperature is displayed in Celsius or Fahrenheit. • Function Code 05 : Setting Temperature Selection The unit can be operated according to air temperature or leaving water temperature. The selection for setting temperature as air temperature or leaving water temperature is determined. Note : Air temperature as setting temperature is ONLY available when Remote Air Sensor Connection is enabled and Function Code 03 is set as 02. • Function Code 06 : Auto Dry Contact This function enables the Dry Contact to operate under Auto Run mode or Manual mode with remote controller. If thermostat is used, value should be changed from "2" to "1". • Function Code 07 : Address Setting When Central Controller is installed, address assigning is set by this function. • Function Code 08 : Override Setting Override master/slave selection function is to prevent the unit’s different mode operation. If the unit is set as the slave, it blocks a change of opposite operating mode(cooling/heating). ❈ To use override master/slave selection function is only possible when units are connected in series to the outdoor unit. • Function Code 09 : Water Pump Test Run After water pipe work is done, Water Pump Test Run mode should be performed to check whether water circulation is normal. 42 Hydro Kit System Set-Up • Function Code 13 : Setting Air Temperature in Heating Mode Determine heating setting temperature range when air temperature is selected as setting temperature. CAUTION Only available when remote air temperature sensor is connected. • Accessory PQRSTA0 should be installed. • Also, Function Code 03 should be set properly. • Function Code 14 : Setting Leaving Water Temperature in Heating Mode Determine heating setting temperature range when leaving water temperature is selected as setting temperature. • Function Code 15 : Setting Sanitary Tank Leaving Water Temperature Determine heating setting temperature range of water tank leaving water. NOTICE Only available when sanitary water tank temperature sensor is installed. • Sanitary water tank and sanitary water tank kit should be installed. • DIP switch No. 2 and 3 should be set properly. • Function Code 17 : Setting Operation mode lock. Set the Operation mode lock when Multi V Indoor unit is used only cooling mode in summer and Hydro Kit is used only heating in winter. NOTICE CH51 error occur when Combination Ratio exceed limitation without setting operation mode lock. Multi V indoor unit can’t be operated heating mode and Hydro Kit can’t be operated cooling mode when operation mode lock is set. It can’t be operated with Multi V Indoor unit and Hydro Kit simultaneously when operation mode lock is set. Hydro Kit Installation Manual 43 ENGLISH Temperature Range Setting System Set-Up Temperature Control Parameter Setting and Etc • Function Code 23, 24, and 25 : Setting Weather-dependent operation Weather-dependent operation is that the unit automatically adjusts target temperature (leaving water or room air) according to the outdoor air temperature. - Value #1 and Value #2 of Function Code 23 : range of outdoor air temperature - Value #1 and Value #2 of Function Code 24 : range of auto-adjustable target room air temperature - Value #1 and Value #2 of Function Code 25 : range of auto-adjustable target leaving water temperature Note : Weather-dependent operation is applied for heating mode only. Auto-Adjustable Target Temperature Temperature profile of Weather-dependent operation Value #1 of Function Code 24 or 25 Value #2 of Function Code 24 or 25 Value #2 of Function Code 23 44 Hydro Kit Value #1 of Function Code 23 Outdoor air temperature System Set-Up Temperature profile of Disinfection operation Water temperature (Inside sanitary water tank) Value #1 of Function Code 27 Value #2 of Function Code 27 Value #2 of Function Code 26 Time WARNING Vales of Function Code 26 • If Value #1 of Function Code 26 is set as ’00’, Value #2 and Value #3 is not used. • When Value #1 is set as ’01’, Value #2 is displayed at the position of Value #1 and Value #3 is displayed at the position of Value #2 due to limited width of the control panel display. CAUTION Sanitary water heating should be enabled • If sanitary water heating is disabled, the disinfection mode will not be operated although Value #1 of Code 26 is set as ’01’. • To use disinfection mode, sanitary water heating should be enabled. Press repeatedly tank heating Button to enable sanitary <Sanitary Water Heating Disable> <Sanitary Water Heating enable> Hydro Kit Installation Manual 45 ENGLISH • Function Code 26 and 27 : Setting Disinfection operation Disinfection operation is special sanitary tank operation mode to kill and to prevent growth of viruses inside the tank. - Value #1 of Function Code 26 : Selecting disinfection operation mode. ‘00’ for setting disinfection mode off, and ‘01’ for setting disinfection mode on. - Value #2 of Function Code 26 : Determining the date when the disinfection mode is running. ’01’ for Sunday, ’02’ for Monday, … , and ’06’ for Saturday. - Value #3 of Function Code 26 : Determining the time when the disinfection mode is running. ’00’ for 0:00am, ’01’ for 01:00am, … , ’22’ for 10:00pm, and ’23’ for 11:00pm. - Value #1 of Function Code 27 : Target temperature of disinfection mode. - Value #2 of Function Code 27 : Duration of disinfection mode. System Set-Up • Function Code 28 and 29 : Setting control parameter for Sanity water heating operation Descriptions for each parameters are as following. - Value #1 of Function Code 28 : temperature gap from Value #2 of Function Code 28. - Value #2 of Function Code 28 : maximum temperature. - Example : If Value #1 is set as ‘5’ and Value #2 is set as ’80’, then water tank heating will be started when the water tank temperature is below 75°C(167°F). - Value #1 of Function Code 29 : temperature gap from target sanitary water temperature. - Value #2 of Function Code 29 : Determining heating demand priority between sanitary water tank heating and under floor heating. - Example : If user’s target temperature is set as ’50’ and Value #1 is set as ‘3’, then water tank heating will be turned off when the water temperature is above 53°C(127°F). Water tank heating will be turned on when the water temperature is below 50°C(122°F). - Example : If Value #2 is set as ‘0’, that means heating priority is on sanitary water heating, In this case the under floor can not be heated while sanitary water heating. On the other hand, if the Value #2 is set as ‘1’, that means heating priority is on under floor heating, sanitary tank can not be heated while under floor heating. NOTICE Sanitary water heating does not operate when it is disabled. Enabling / Disabling sanitary water heating to operate is determined by pushing When button. icon is displayed on the remote controller, sanitary water heating is enabled. (by button input or scheduler programming) ?)<-: 0-)<16/ ?)<-: 0-)<16/ 78-: 57,- • Function Code 2B : Setting sanitary water heating timers Determine time duration : Operation time and stop time of sanitary tank heating. <-58 - Value #1 of Function Code 2B : This time duration defines how long sanitary tank heating can be continued. - Value #2 of Function Code 2B : This time duration defines how long sanitary tank heating can be stopped. It is also regarded as time gap between sanitary tank heating cycle. - Example of timing chart : Sanitary tank heating is enabled Sanitary tank heating is required 2B.02 2B.01 2B.02 2B.01 2B.02 Sanitary tank heating operation Time 46 Hydro Kit 78-: 57,- <-58 System Set-Up 2F : Entering/Leaving Water temperature 2E : Room Air temperature Th On Th Off Th On Th Off 0 -0.5°C 1.5°C 0 -2°C 2°C 1 4°C 6°C 1 -6°C 4°C 2 2°C 4°C 2 -2°C 4°C 3 -1°C 1°C 3 -1°C 1°C • Function Code 30 : Remote Controller Program Version Display Remote Controller Program Version. • Function Code 33 : Changing thermal on/off temperature in Hot water Mode Select Thermal on/off Temperature gap. Function code 33 : Sanitary Tank water temperature Th On Th Off 0 -2°C 2°C 1 -6°C 4°C 2 -2°C 4°C 3 -1°C 1°C • Function Code 34 : Setting control parameter for Water flow temperature. Select entering/leaving water Temp in Heating Mode. • Function Code 37 : Water pump operation/delay time set in heating mode. • Function Code 39 : Setting of Forced product operation. • Function Code 41 : Setting of Dry Contact installation set. Hydro Kit Installation Manual 47 ENGLISH • Function Code 2E and 2F : Changing thermal on/off temperature Select Thermal on/off Temperature gap. Test Run 7. Test Run Caution before Operation Test • Check whether water flow is smoothly supplied. • Check whether the flow switch properly operates. • Check whether the connection status is good. • Check whether the power cable and communication cable are completely connected. • Check whether it is 2.0MΩ or above, when insulation resistance between the terminal block and ground is measured with DC mega tester (DC 500V). • Never check insulation resistance for the connector of the control board. Operation Test of Water Pipe Category Status Checkpoint Check whether operation of water pipe is normal. Flow Switch Error CH14 Check for the block inside water pipe. (Strainer cleaning, valve locked, valve malfunction, air remaining, etc.) Check problem with flow switch. (Flow switch disorder, untold operation, disconnection, etc.) 48 Hydro Kit Test Run • This function displays the disorder types at the self diagnostics and the occurrence of the disorder for the product. • If two or more types of disorders occur simultaneously, it displays in the order of the error number. • If inverter PCB error occurs, No. 12 error is displayed in the remote controller, and inverter PCB board LED can be used to verify detail error display. • After error occurs, the error code disappears when the disorder is repaired. ❈ Error code 01, 08, 17, 18 can be operated with emergency operation. Error No. 01 02 03 05 06 08 09 Error Type Main Reasons Air temperature sensor disconnection or short circuit Gas side temperature sensor disconnection or Gas side temperature sensor error short circuit No communication between wired re- The remote controller does not receive the signal mote controller & indoor unit from indoor unit during specific time Indoor unit & outdoor unit communica- No signal communication between indoor unit & tion error outdoor unit Liquid side temperature sensor disconnection or Liquid side temperature sensor error short circuit Water tank temperature sensor disconnection or Water tank temperature sensor error short circuit Communication between the micro-processor & Indoor unit EEPROM error the EEPROM / Error due to EEPROM damage Air temperature sensor error 11 Indoor unit & inverter PCB communication error No signal communication between indoor unit & inverter PCB 12 Inverter PCB error Error occurrence in inverter PCB 14 Flow switch error Abnormal working of flow switch 15 Water pipe overheated 16 Water inlet & outlet temperature sensor error 17 Water inlet temperature sensor error Water inlet temperature sensor disconnection or short circuit 18 Water outlet temperature sensor error Water outlet temperature sensor disconnection or short circuit Water outlet temperature is above 85℃ (Applied for Mid Temperature model) Water inlet & outlet temperature sensor disconnection or short circuit simultaneously Hydro Kit Installation Manual 49 ENGLISH Troubleshooting Test Run Inverter PCB error display method Red LED means error number 10 digits, and green LED means 1 digit, and if red and green blink at the same time, it means the unit of 100. Ex) When red and green LED blink once at the same time, and red LED blinks once, and green LED blinks once: error number 115 Error No. Error Type Red LED: 10 digits Green LED: 1 digit Main Reasons 21 Inverter compressor IPM defect 22 Inverter compressor overcurrent 23 Inverter compressor DC Link low voltage 25 High/low Inverter input voltage 26 Inverter compressor activation failure 27 Inverter PSC/PFC Fault Error 28 Inverter DC Link high voltage error 29 Inverter compressor overcurrent Inverter compressor drive IPM defect / inverter compressor defect Increase of inverter compressor CT value After inverter activation relay is ON, DC voltage recharge defect Inverter input voltage exceeds the unit limit and lasts for 4 s (173V ~ 289V) Inverter compressor error, causing initial activation failure Error by overcurrent at inverter input Inverter DC voltage recharge, causing compressor OFF Inverter compressor activation failure or increase of CT value 32 Excessive rise of inverter compressor discharge temperature Excessive rise of inverter compressor discharge temperature, causing compressor OFF 34 35 Excessive rise of high pressure of inverter compressor Excessive drop of low pressure of inverter compressor Excessive rise of high pressure of inverter compressor, causing compressor OFF Excessive drop of low pressure of inverter compressor, causing compressor OFF 36 Low pressure ratio error of inverter compressor 40 41 42 43 44 46 53 60 62 65 73 High pressure/low pressure ratio of inverter compressor is maintained at below 1.8 for 3 min. or more Inverter compressor CT sensor defect Inverter compressor CT sensor defect Inverter compressor discharge pipe temInverter compressor discharge temperature perature sensor defect sensor disconnection or short circuit Low pressure sensor defect of inverter Low pressure sensor disconnection or short compressor circuit of inverter compressor High pressure sensor defect of inverter High pressure sensor disconnection or compressor short circuit of inverter compressor Inverter inside air temperature sensor deInverter inside air temperature sensor disfect connection or short circuit Inverter compressor suction pipe tempera- Inverter compressor suction temperature ture sensor defect sensor disconnection or short circuit Communication error(indoor unit → outdoor Outdoor unit does not receive signal from indoor unit unit main PCB) Inverter PCB EEPROM error Inverter PCB EEPROM error Excessive rise of inverter heatsink temper- Inverter PCB heat generation, causing the ature rise of heatsink temperature heatsink temperature sensor disInverter heatsink temperature sensor defect Inverter connection or short circuit Overcurrent (Peak) detected at inverter Error by overcurrent detection at inverter input input 50 Hydro Kit
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project