LG | HS-C0964DA3 | LG HS-C1264DA2 Owner’s Manual

website http://www.lgservice.com
LG
Room Air Conditioner
OWNER'S MANUAL
MODELS : S4/S5 Chassis
Prior to installation, this airconditioning unit must be
submitted for approval by the
utility service which provides
electricity (EN 61000-2,
EN 61000-3 Norm).
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
ENGLISH
LG
�
�
Ope ration indicating
lamps
About the remote control on the system
Features of the Remote Control
Remote Controller
1
Signal transmitter
2
Transmits the signals to the room air
conditioner.
OPERATION DISPLAY
Displays the operation conditions.
AIRFLOW DIRECTION START/STOP
BUTTON
Used to stop or start louver movement and
set the desired up/down airflow direction.
3
OPERATION MODE SELECTION
BUTTON
Used to select the operation mode.
1
4
OFF TIMER BUTTON
Used to set the time of stopping operation.
3
4
5
8
2
7
5
6
ROOM TEMPERATURE SETTING
BUTTONS
6
7
INDOOR FAN SPEED SELECTION
BUTTON
8
JET COOL OPERATION BUTTON
Used to start or stop the speed (speed cooling
operates super high fan speed in cooling mode.)
TEMP.
OFF
TIME
hr.
START/STOP BUTTON
Operation starts when this button is
pressed, and stops when the button is
pressed again.
5
Sa f e ty Pre ca u ti o n s
Operation Mode Selection button
Features of the Remote Control
(1) OPERATION MODE
Tro u b l e sh o o ti n g Ti p s
Ca re a n d Ma i n te n a n ce
O p e ra ti n g I n stru cti o n s
Cooling Mode
6
Healthy Dehumidification Operation
(Cooling Model)
(2) OPERATION PROCEDURE
1st
Start/Stop Button
TEMP.
OFF
2nd
Operation Mode Selection
Button
3rd
Room Temperature
Setting Button
TIME
hr.
2
4
1
3
4th
Indoor Fan Speed
Selection Button
�
TEMP.
OFF
TIME
hr.
TEMP.
OFF
TIME
hr.
Cooling
OFF
TIME
hr.
Healthy
Dehumidification
TEMP.
�
OFF
TIME
hr.
Set the fan speed.
TEMP.
OFF
TIME
hr.
7
Select Healthy Dehumidification Operation.
OFF
TIME
hr.
Press the operation Mode Selection Button.
Each time the button is pressed, the operation mode is
shifted in the arrow direction.
TEMP.
OFF
TIME
hr.
Cooling
Set the fan speed.
TEMP.
�
OFF
TIME
OFF
TIME
hr.
Healthy
Dehumidification
• Select the fan speed
in two steps
-low, high.
• The display shows
high fan speed.
hr.
• The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is
impossible because of already being set to the best speed for Dry Operatrion by Micom
Control.
• The indoor fan may be stopped not so as to be the room overcooling.
8
TEMP.
OFF
TIME
hr.
Press the Jet Cool button to operate
the speed cooling mode and the unit
will operate at super high fan speed
on cooling mode for 30 minutes.
To cancel the Jet Cool mode, press the Jet Cool button, the
fan speed button or the room temperature setting button
again and the unit will operate at high fan speed on cooling
mode.
�
OFF TIMER CONTROL SETTING
TEMP.
OFF TIME
TIME
OFF
hr.
hr.
Press the OFF Time Button.
ep
, Be
Beep
�
1. Press the OFF Time Button.
2. Check the OFF Time LED of the room air conditioner.
3. The Timer is programmed by 1 hour each
pressing the OFF Time button from 1 hour to 7 hours.
9
Airflow Direction Control
The airflow direction can be adjusted as desired by
using the remote controller. This is effective when you
want to cool yourself directly, such as after taking a
bath.
1
Press the Start/Stop Button.
(Confirm the unit on operation.)
2
Press the Airflow Direction Control
Button and the vertical louvers swing up
and down automatically.
3
Press again the Airflow Direction
Control Button to set the vertical louver
at the desired airflow direction.
Horizontal Airflow Direction Control
• Adjust the horizontal airflow direction by manually
moving the horizontal airflow direction louver by
hand.
Caution
• Always use the remote controller to adjust
the airflow direction. Manually moving the
vertical airflow direction louver by hand could
cause operation errors.
• When air conditioner operation is stopped,
the vertical airflow direction louver will close
the air outlet vent of room air conditioner.
10
ON/OFF
button
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, Press and hold the ON/OFF button for 3~5 seconds, then the buzzer sound 1
"beep".
If you want to stop the operation, re-press the button.
High
Speed
11
�
Air inlet vent
Air filters
(behind front panel)
Vertical louver Horizontal louver
12
Air outlet vent
The heat exchanger coils and panel vents of the outdoor unit should be checked regularly.
If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam
cleaned.
NOTE:
Dirty or clogged coils will reduce the
operating efficiency of the system and cause higher operating costs.
13
9
12
7
�
15
P/No.:MFL30291710