LG | C09AWB-SU0 | LG C09AWB SU0 Owner’s Manual

website
http://www.lgservice.com
LG
LG Room
Air Conditioner
OWNER'S MANUAL
MODELS: AS
-
W096_Series
W126_Series
C09AW_Series
C12AW_Series
Prior to installation, this airconditioning unit must be
submitted for approval by the
utility service which provides
electricity (EN 61000-3 Norm).
IMPORTANT
?
?
Please read this owner's manual
and
before
air conditioner.
installing
and
carefully
operating your room
thoroughly
Please retain this owner's manual for future reference after
reading it thoroughly.
ENGLISHTAOPFRCDU
GRE K
Room Air Conditioner Owner's Manual
TABLE OF CONTENTS
Safety
Precautions.........................3
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Prior to
Operation
..........................6
Serial #
You
find them
can
on a
label
on
the side of each unit.
Dealer's Name
Introduction ....................................7
Date Purchased
your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
Staple
Electrical
Operating
Safety
.............................8
Instructions.................10
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive
care on
of time and money
Maintenance and Service ............24
your part can save you a great deal
the life of your air conditioner.
over
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first,
you may not need to call
for service at all.
PRECAUTION
?
Contact the authorized service technician for
repair
or
maintenance of this unit.
?
Contact the installer for installation of this unit.
?
The air conditioner is not intended for
young children
?
?
2
Room Air Conditioner
use by
supervision.
supervised to ensure
invalids without
Young children should be
they do not play with the
that
?
or
When
air conditioner.
power cord is to
replacement work shall be
be replaced,
performed by
authorized personnel only using only genuine
replacement parts.
Installation work must be performed in
accordance with the National Electric Code by
qualified and authorized personnel only.
the
Safety Precautions
Precautions
Safety
To
prevent the injury of the
user or
other
people
and
property damage, the following instructions
must be
followed.
Incorrect
by
the
operation due to ignoring
following indications.
This
This
The
of the
meanings
symbols
instruction will
symbol
indicates the
symbol
indicates the
used in this manual
sure
or
damage.
possibility
of death
or
possibility
of
or
are as
Be
Be
harm
cause
injury
The seriousness is classified
serious
injury.
damage
to
ENGLISH
properties only.
shown below.
sure
not to do.
to follow the instruction.
Installation
Don't
Always perform grounding.
plug
power cord,
loose socket
use a
or a
which is
For installation of the product,
always contact the service
center or a professional
a
damaged.
installation agency.
?
Otherwise, it may
cause
?
electrical shock.
Otherwise, it may
or
cause a
fire
?
electrical shock.
Otherwise, it may cause a fire,
electrical shock, explosion or
injury.
Securely
attach the
Always
panel
?
switching
If the electrical
part
cover
of the outdoor unit
attached
in
a
an
air
Do not
leakage
fire
or
keep
or use
flammable gases or
combustibles near the air
dedicated
board.
conditioner.
of the
?
No installation may cause
and electrical shock.
a
fire
?
Otherwise, it may
or
the failure of
cause a
fire
product.
not
are
it could result
securely,
electric shock due to
dust, water,
etc.
Ensure that
an
Do not disassemble
installation
frame of the outdoor unit is
not damaged
alongtime.
?
a
to the outdoor unit.
indoor unit and the service
panel
install
breaker and
electrical part cover to the
indoor unit and the service
It may cause
accident.
due to
injury
use
for
or an
or
repair the product
randomly.
?
It will
cause a
shock.
fire
or
Do not install the
place that ther
of falling down.
a
electrical
product
is
at
concern
?Otherwise,itmayresultin
personal injury.
Use caution when
unpacking
?
and
Sharp edges
installing.
may
cause
injury.
Owner's Manual
3
Safety Precautions
Operation
Do not share the outlet with
Do not
other
power cord.
It will
?
appliances.
electric shock
cause an
fire due to heat
a
Take
care so
or
?
generation.
Otherwise, it may
or
cause a
comes
fire
?
electrical shock.
Take the power
cause a
fire
?
Otherwise, it may
or
the unit if strange
or smoke
the
fire
cause a
electrical shock.
Keep the flames
away.
from it.
Otherwise, it may
electrical shock
plug
modify or extend
randomly.
power cord
sounds, smell,
pulled
during operation.
?
Do not
damaged
electrical shock.
Unplug
cord may not be
the
Otherwise, it may
or
that the power
use
out if
Do not
necessary, holding the head
of the plug and do not touch
near
use
the
?
cause
or a
Otherwise, it may
fire.
cause a
fire.
the power cord
tools.
Do not open the suction
inlet of the indoor/outdoor
heating
unit
during operation.
it with wet hands.
Otherwise, it may
?
or
cause a
fire
?
electrical shock.
Otherwise, it may
cause a
fire
?
and electrical shock.
Do not allow water to
Hold the
run
when
into electrical parts.
plug by the
taking it out.
Otherwise, it may electrical
shock and failure.
head
Never touch the metal
of the unit when
parts
removing
the filter.
?
Otherwise, it may
cause
failure of machine
or
the
?
It may
cause
electrical
damage.
well
When
electric shock and
?
They are sharp
injury.
and may
cause
shock.
Ventilate the
room
when
make
An oxygen
?
shortage
may
occur.
?
sure
Otherwise, it may
step
on
Do not
the
indoor/outdoor unit and do
not
put anything
It may
?
cause an
dropping
on
injury through
or falling
of the unit
care so
may not
step
that children
on
the outdoor
unit.
?
Otherwise, children may be
seriously injured
due to
falling
down.
4
place
a
Room Air Conditioner
a
long
time.
When the
product is
submerged into water, always
heavy object
the power cord.
contact the service center.
it.
down.
Take
on
product for
?Otherwise,itmaycausethe
failure of product or a fire.
cause
electrical shock.
Do not
Turn off the main power
switch when not using the
the unit, first
cleaning
the power and
breaker are turned off.
using this appliance
together with a stove, etc.
?
Otherwise, it may
or
cause a
electrical shock.
fire
?
Otherwise, it may
or
cause a
electrical shock.
fire
Safety Precautions
Installation
Install the drain hose to
can
?
be
Otherwise, it may
ensure
that drain
Install the
done.
securely
cause
product
so
that the noise
wind from the outdoor unit may not
any damage to the neighbors.
water
leakage.
?
Otherwise, it may
cause
or
ENGLISH
hot
cause
with the
dispute
neighbors.
Always inspect
installation and
?
Otherwise, it may
leakage after the
repair of product.
Keep
gas
cause
the failure of
product.
?
level
parallel
Otherwise, it may
in
cause
installing
vibration
the
or
product.
water
leakage.
Operation
Avoid excessive
cooling
and
Useasoftclothtoclean.Donotusewax,
thinner, or a strong detergent.
perform
ventilation sometimes.
?
Otherwise, it may do harm
to your health.
?
The appearance of the air conditioner may
deteriorate, change color, or develop surface
flaws.
When gas leaks, open the window for
ventilation before operating the unit.
Do not
appliance for special
as preserving animals
vegetables, precision machine, or art
use an
purposes such
articles.
?
Otherwise, it may
Do not
or
?
place
explosion,
and
fire.
obstacles around the flow inlet
Otherwise, it may damage your properties.
Always
insert the filter
securely.
Clean it
every two weeks.
cause
the failure of
appliance
or
?
Operation
without the filter will
cause
failure.
accident.
Do not insert the hands
air inlet
?
a
outlet.
Otherwise, it may
an
cause
?
or
outlet
Otherwise, it may
or bars through
during operation.
cause
personal injury.
Do not drink water
the
coming
out of the air
conditioner.
?
Otherwise, it may
cause
stomachache.
Owner's Manual
5
Prior to
Operation
Prior to
for
Preparing
1. Contact
2.
3. Use
Operation
installation
an
in the power
Plug
Operation
specialist
plug properly.
for installation.
dedicated circuit.
a
4. Do not
use an
extension cord.
5. Do not
6. If the
start/stop operation by plugging/unplugging the power cord.
cord/plug is damaged, replace it with only an authorized replacement part.
Usage
1.
a long time may be hazardous to your health. Do not expose
plants to direct airflow for a long time.
Due to the possibility of oxygen deficiency, ventilate the room when using the appliance together with
stoves or other heating devices.
Do not use this air conditioner for non-specified special purpose (e.g. preserving precision devices,
food, pets, plants, or art objects). Such use may damage your properties.
Being exposed
to direct airflow for
occupants, pets,
2.
3.
Cleaning
or
and Maintenance
1. Do not touch the metal
2. Do not
3.
parts of the unit when removing the filter. Injury
water to clean inside the air conditioner.
Exposure
to water
Service
For
6
can occur.
destroy the insulation,
leading to electric shock.
When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at
very high speed during operation. There is a possibility of injury if the unit's power is triggered while
cleaning inner parts of the unit.
use
repair
and
maintenance,
Room Air Conditioner
contact your authorized service dealer.
can
a
Introduction
Introduction
Symbols
used in this Manual
This
symbol
This
symbol
alerts you to hazards that may
air conditioner.
NOTICE
This
symbol
ENGLISH
alerts you to the risk of electric shock.
indicates
special
cause
harm to the
notes.
Features
WARNING: This
regulations.
Indoor
appliance should be installed in accordance with national wiring
guide acts as a guide to help to explain product features.
This
Air Inlet
NANO Plasma Filter
Air Filter
Air
Discharge
Front Panel
Power Cord
Signal Receptor
Power button
Outdoor
Air Intake Vents
Connecting
Wires
Piping
Air Outlet Vents
Base Plate
Drain Hose
Owner's Manual
7
Electrical
Safety
Electrical
Safety
WARNING: This
To minimize the risk of electric
appliance
shock, you
must
must be
properly grounded.
alway plug
into
a
grounded
oulet.
Preferred method
Ensure proper ground
exists before use
WARNING: Do not cut
power
or remove
the
grounding prong
from the
plug.
WARNING:
Attaching
receptacle
cover screw
the
adapter ground terminal to the wall
ground the appliance unless the
cover screw is metal and not insulated, and the wall receptacle is
grounded through the house wiring.
does not
WARNING: If you have any doubt whether the air conditioner is
properly grounded, have the wall receptacle and circuit checked
a
8
qualified
electrician.
Room Air Conditioner
by
Electrical
Temporary
Use of an
Safety
Adapter
We
strongly discourage the use of an adapter due to potential safety hazards. For temporary
use only a UL-listed adapter, available from most local hardware stores. Ensure that the
large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal
damage.
connections,
Temporary
ENGLISH
method
Adapter Plug
Metal Screw
Receptacle
WARNING: Never
Temporary
We
use
the
appliance with
Cover
a
broken
adapter.
Use of an Extension Cord
strongly discourage the use of an extension cord due to potential safety hazards. For temporary
use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.
situations,
Owner's Manual
9
Operating
Instructions
Instructions
Operating
Remote Controller
1. Remove the
battery
by pulling
cover
it
to the
according
arrow
direction.
2. Insert
batteries
new
installed
making
sure
that the
(+)
and
(-)
of
battery
are
correctly.
3. Reattach the
cover
Use 2
NOTICE
by sliding
it back into
position.
AAA(1.5volt) batteries.
use rechargeable batteries.
Do not
and
Storage
?
Tips
for
using
The remote controller may be stored
itonawall.
the Remote Controller
by mounting
?
To
operate the
room
air
remote controller at the
conditioner, aim the
signal receptor.
Signal Receptor
Receives the
signals
Operation
from the remote
Indication
On/Off
control.(Signal receiving
the
during
:
Lights
up
during Sleep
Timer
:
Lights
up
during
Preheat Mode
:
Mode
or one
long beep.)
system operation.
Lights
Sleep
beeps
Lamps
up
:
sound: two short
Timer
Mode Auto
operation.
operation.
Lights up during Defrost Mode or Hot
operation (Heat pump model only)
Start
:
Indicates the
Plasma
:
Light up during PLASAM purification
operation.(optional)
Energy-Saving
:
Display
PLASMA
Operation
10
Light
up
during Energy-Saving cooling
Cooling
heating
indicator
dehumidification
Shape of
display
Setting
temp.
setting temperature.
A.I
Standard
Room Air Conditioner
Too hot
operation
Hot
Operation indicating
lamps
mode
operation. (optional)
mode
Comfortable
Cold
Too cold
Jet
Test
Energy-saving
(Cool, Heat) cooling mode operation
Operating
Remote Control
The controls will look like the
Instructions
Operations
following.
Signal
transmitter
ENGLISH
1. START/STOP BUTTON
Operation starts when this button is pressed
and stops when the button is pressed again.
2. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3. ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high and CHAOS.
5
5. JET COOL / HEAT
Used to start or stop the
speed cooling or heating.
(Speed cooling or heating operates super high fan
speed in cooling or heating mode.)
1
6
3
6. CHAOS SWING BUTTON
Used to stop or start louver movement and
set the desired up/down airflow direction.
10
7. ON/OFF TIMER BUTTONS
Used to set the time of starting and
4
2
CANCEL
9
7
ON
12
AUTO CLEAN
11
8. TIME SETTING BUTTONS
Used to adjust the time. (See page
17
8
21)
9. TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is obtained and
to cancel the Timer operation. (See page 21)
13
14
16
15
stopping operation.
(See page 21)
SET
OFF
10. SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation.
(See page 21)
Flip-up door
(opened)
Operation
11. ENERGY-SAVING COOLING MODE BUTTON
(OPTIONAL)
Used to set Energy-Save
in
cooling
mode.
12. ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
Mode
13.
Cooling Operation
PLASMA(OPTIONAL)
Used to start
or
stop the plasma-purification function.
(See page 19)
Auto
Operation
or
Auto
Changeover
14. HORIZONTAL AIRFLOW DIRECTION CONTROL
BUTTON (NOT ON ALL MODELS)
Used to set the desired horizontal airflow direction.
Healthy Dehumidification Operation
(See page 22)
15. RESET BUTTON
Used prior to resetting time
Heating Operation
?
Cooling Model(
), Heat Pump Model(
)
16. 2nd F BUTTON
Used prior to using modes
buttons. (See page 20)
or
after
printed
replacing
batteries.
in blue at the bottom of
17. AUTO CLEAN(OPTIONAL)
Used to set Auto Clean mode.
Owner's Manual
11
Operating
Instructions
Cooling operation
1
Press the
a
2
Start/Stop button.
respond with
The unit will
beep.
Open
the door
on
the remote control.
To select
Cooling Operation
Operation.
or
Auto
Cooling
changeover
3
Healthy Dehumidification
Healthy
Dehumidification
Heating
(Heat pump model only)
Press the Jet Cool button to
operate the speed cooling mode
operate in super high fan speed on cooling
and the unit will
mode for 30 minutes.
ON
To raise the temperature
To lower the temperature
4
To cancel the Jet Cool
the Jet Cool button
button
the
or
mode, press
the fan
speed
temperature setting
button again and the unit will operate in
high
Natural wind by the CHAOS
For fresher
blows like
12
a
or
fan
room
speed
on
cooling
mode.
logic
press the Indoor fan speed selector and set to CHAOS mode. In this mode, the wind
natural breeze by automatically changing fan speed according to the CHAOS logic.
feeling,
Room Air Conditioner
Operating
Auto
Instructions
changeover operation
1
Press the
a
2
Start/Stop button.
respond with
beep.
Open the door of the remote controller. To select Auto Changeover
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is shifted in the
direction of the
arrow.
Cooling
3
ENGLISH
The unit will
Auto
changeover
Healthy
Dehumidification
Heating
(Heat pump model only)
Close the door of the remote controller. Set the
lower than the
set within
a
ON
room
temperature
temperature. The temperature can be
range of 18°C~30°Cat intervals of 1°C.
To raise the temperature
To lower the temperature
4
Set the fan
speed again
with the door
of the remote controller still closed.
You
can select the fan speed in four
steps-low, medium, high and CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
During Auto changeover Operation
The air conditioner changes the operation
mode automatically to keep indoor temperature. When
temperature vary over ±2°C with respect to setting temperature, air conditioner keeps the
temperature within ±2°C with respect to setting temperature by auto changeover mode.
room
room
Owner's Manual
13
Operating
Auto
Instructions
operation (Optional)
1
Press the
a
2
Start/Stop button.
respond with
The unit will
beep.
Open the door of the remote controller. To select Auto
Operation, press the operation mode selection button.
Each time the button is pressed, the operation mode is
shifted in the direction of the
Auto
Cooling
3
ON
The
arrow.
Healthy
Heating
(Heat pump model only)
Dehumidification
temperature and fan speed
electronic controls based
on
are
automatically
the actual
room
set
by
the
temperature. If
change the set temperature, press the Room
Temperature Setting buttons. The cooler or warmer you feel,
themoretimes(uptotwotimes)youshouldpressthebutton.
The set temperature will be changed automatically.
you want to
To raise the temperature
To lower the temperature
During Auto Operation
You cannot control the indoor fan
If the
system is
not
operating
It has
already
been set
desired, manually switch
by
the
Fuzzy
rule.
to another mode. The
system will
not
cooling mode to the heating mode, or from heating mode to cooling
mode, it must be done by manually resetting.
During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the chaos swing button again.
automatically
14
switch from the
speed.
as
Room Air Conditioner
Operating
Healthy
dehumidification
Instructions
operation
Press the
1
ENGLISH
Start/Stop button.
respond with
The unit will
a
beep.
Open
2
the door of the remote controller. To select
Dehumidification
Operation,
press the
Healthy
Operation Mode
Selection button.
Each time the button is
pressed,
the
operation
mode is
shiftedinthedirectionofthearrow.
Auto
Cooling
changeover
Set the fan
3
speed again
Healthy
Dehumidification
Heating
(Heat pump model only)
with the door
of the remote controller still closed.
You
can select the fan speed in four
steps-low, medium, high, or CHAOS.
Each time the button is pressed, the
fan speed mode is shifted.
ON
Natural wind
by the
For fresher
feeling,
CHAOS
logic
press the Indoor Fan Speed Selector and set
to CHAOS mode. In this mode, the wind blows like a natural
breeze
CHAOS
by automatically changing
logic.
fan
speed according
to the
During Healthy Dehumidification Operation
If you select the dehumidification mode on the operation selection button, the A/C starts to run the
dehumidification function. It automatically sets the room temp. and airflow volume to the best
condition for
dehumidification, based
In this case, however, the setting
control the room temp. either.
temp.
on
the sensed current
is not
displayed
on
room
temp.
the remote controller and you
are
not able to
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status, so that the room condition is kept
healthy and comfortable even in the very humid season.
Owner's Manual
15
Operating
Instructions
model
Heating operation (Heat pump
1
Press the
Start/Stop button.
respond with
The unit will
a
2
only)
beep.
Open the door of the remote controller. To select Heating
Operation, press the Operation Mode Selection button.
Each time the button is pressed, the operation mode is
shiftedinthedirectionofthearrow.
Auto
Cooling
Healthy
changeover
3
Dehumidification
Heating
(Heat pump model only)
Close the door of the remote controller.
Set the
The
temperature higher than the room temperature.
temperature can be set within a range of 16°C~30°Cat
intervals of 1°C.
ON
To raise the temperature
To lower the temperature
4
Set the fan
speed again
with the door of the
remote controller still closed. You
select the fan
speed
in four
can
steps--low,
medium, high and CHAOS. Each time the
button is
pressed,
the fan
speed
mode is
shifted.
Natural wind
For fresher
by the
wind blows like
16
CHAOS
a
logic
press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the
natural breeze by automatically changing fan speed according to the CHAOS logic.
feeling,
Room Air Conditioner
Operating
Jet cool
Instructions
operation
1
Press the
a
2
ENGLISH
Start/Stop button.
respond with
The unit will
beep.
Press the Jet Cool button to
and the unit will
operate
operate the speed cooling mode
at super
high
fan
speed
on
cooling
mode for 30 minutes.
Auto
Cooling
changeover
3
Healthy
Dehumidification
Heating
(Heat pump model only)
To cancel the Jet Cool
mode, press the Jet
button, the fan speed button or the room
temperature setting button again and the unit
will operate at high fan speed on cooling
Cool
mode.
ON
4
To cancel the Jet Cool
mode, press the Jet Cool button or
room temperature setting button
again and the unit will operate in high fan speed on cooling
the fan
speed
button
or
the
mode.
or
or
NOTICE
During the JET COOL function at any moment, the A/C starts to blow the cool air at extremely high
speed for 30 minutes setting the room temp. automatically to 18°C. It is especially used to cool the
room temp. quickly in a hot summer.
In heat pump mode, neuro fuzzy mode, or auto changeover mode however, the JET COOL function
is not available.
In order to return to the normal
mode selection
cooling mode from the JET COOL mode, just press the operation
button, airflow volume selection, temp. setting button or the JET COOL button again.
Owner's Manual
17
Operating
Instructions
Jet heat
operation (Optional)
Press the
1
Start/Stop button.
respond with
The unit will
a
beep.
Open
2
the door of the remote controller.
To select
Heating Operation.
Auto
Cooling
Healthy
Dehumidification
changeover
Press the Jet Heat button to
3
speed heating
Heating
(Heat pump model only)
operate the
mode and the unit will
at super high fan
mode for 60 minutes.
operate
speed
on
heating
ON
To cancel the Jet Heat
4
mode, press the Jet Heat button,
the fan
speed button or the room temperature setting
button again and the unit will operate at high fan speed on
heating mode.
or
or
NOTICE
During
the JET HEAT function at any moment, the A/C starts to blow the heat air at extremely high speed for
setting the room temp. automatically to 30°C. It is especially used to heat the room temp. quickly
60 minutes
in
a
On
cool winter.
cooling, healthy
dehumidification mode
or
auto
changeover mode, however,
the JET HEAT function is not
available.
In order to return to the normal
selection
18
heating
mode from the JET HEAT
button, airflow volume selection, temp. setting button
Room Air Conditioner
or
mode, just press the operation mode
the JET HEAT button again.
Operating
PLASMA
Instructions
purification operation(Optional)
1
Press the Start/Stop button.
Theunitwillrespondwitha
beep.
2
Open
ENGLISH
the door of the remote
controller. Press the PLASMA
button.
Operation will start when the button
is pressed and stop when the button
is pressed again.
3
Set the fan
speed again
controller closed. You
with the door of the remote
can
select the fan
speed
in four
steps-low, medium, high or CHAOS.
Each time the button is pressed, the fan
speed mode is shifted.
Air
purifying operation ( PLASMA) can be
cooling, Heating or any other operations.
with
NANO PLASMA Air
Purifying Operation
onlyIf
you press the only PLASMA button, only
PLASMA purification function operates.
Then, fan speed is low. You can select the fan
speed in four steps-low, medium, high or
CHAOS.
Each time the button
speed
(
)
is
pressed,
the fan
mode is shifted.
Owner's Manual
19
Operating
Instructions
2nd F
operation
1
Press the
a
2
Start/Stop button.
respond with
The unit will
beep.
Open
the door of the remote control and press the 2nd
operate functions printed in blue unter
Function button to
buttons.
(Check the indication
remote controller.)
These buttons
can
of 2nd function
set the timer
ON
as
on
the
display
of the
follows:
OFF
SET
CANCEL
ON
OFF
SET
AUTO CLEAN
3
2nd function
the button is
disappears in a
pressed again.
short time
automatically
or
For more details, refer to functions next pages.
20
Room Air Conditioner
when
Instructions
Operating
Additional Features
Sleep
mode
1.PresstheSleepModeAutobuttontosetthetimeyouwanttheunittostopautomatically.
2. The Timer is
in one-hour increments
programmed
by pressing the Sleep
period in steps
mode is available for 1 to 7 times. To alter the time
Mode Auto button 1 to 7 times. The
hour, press the Sleep Mode
aiming at air conditioner.
3. Make sure the Sleep Mode Auto LED lights up.
To cancel the Sleep Mode, press the sleep Mode Auto button several times until the star
(
) disappears from the operation display.
The Sleep Mode will be operated at slow fan speed (cooling) or medium fan speed (heat pump
NOTICE
only) for a comfortable sleep.
sleep
of 1
Button while
In
In
sleep
mode: Chaos
cooling
The
mode
or
temperature will
function does not
Swing
operate.
healthydehumidification mode:
automatically rise by 1°C over the
next 30 minutes and
by
2°C in 1 hour for
a
comfortable
sleep.
Setting
the time
1. Time
can be set only when you press the Reset button. Having replacing the batteries,
you should press the reset buttons to reset the time. Press the Start/Stop button.
2. Press 2nd F button and check if 2nd F icon is
3. Press the Time
Setting
buttons until the desired time is set.
CANCEL
4. Press the Timer SET button.
SET
Check the indicator for A.M. and P.M.
NOTICE
Delay
1. Make
on.
sure
start/Pre-set stop
the time is set
correctly
on
the
display
of the remote controller.
2. Press 2nd F button.
3. Press the ON/OFF Timer buttons to turn Timer
4. Press the Time
Setting
5. To set the selected
on or
off.
ON
OFF
buttons until the desired time is set.
time, press the Timer setting button aiming the
remote controller at the
signal receptor.
CANCEL
SET
To cancel the timer
setting
Checkif2ndFiconisoff.
CANCEL
Press the Timer Cancel button
ET
(The
NOTICE
Delay
timer
Select
lamp
one
OFF Timer
on
aiming
the remote controller at the
the air conditioner and the
of the
following
Delay
four
types of operation.
ON Timer
signal receptor.
display will go out.)
Delay
with the unit
OFF and ON Timer
running
Delay
ON and OFF Timer
Owner's Manual
21
ENGLISH
Operating
Instructions
Vertical Airflow Direction Control
The
up/down airflow (Vertical Airflow)
by using the remote control.
be
can
adjusted
NOTICE
If you press the CHAOS swing button, the horizontal airflow
direction is changed automatically based on the CHAOS
algorithm to
same
distribute the air in the
time to make the human
room
body feel
evenly and
most
at the
comfortable,
if enjoying a natural breeze.
Always use the remote control to adjust the up/down
airflow direction. Manually moving the vertical airflow
direction louver by hand, could damage the air
as
1. Press the
2. Press
Start/Stop button to start the unit.
Chaos Swing button and the louvers will
up and down.
Press the Chaos Swing button
swing
again
conditioner.
When the unit is shut
to set the vertical louver
at the desired airflow direction.
Horizontal Airflow Direction Control
The
off, the up/down airflow direction
system.
louver will close the air outlet vent of the
be
(Optional)
the remote control.
left/right(Horizontal Airflow)
adjusted by using
Start/Stop button to start the unit.
Open the door on the remote control. Press the Airflow Direction Start/Stop button and the
louvers will swing left and right. Press the Horizontal Airflow Direction Control Button again to
can
Press the
set the horizontal louver at the desired airflow direction.
Energy-Saving Cooling
Mode Can
Mode
(Optional)
Energy-Saving Cooling
energy in Cooling and Healthy Dehumidification Operation,
operate efficiently by setting body-adaptation time according to the change of time and temperature
automatically desired temperature.
1. Press the
2.
22
Start/Stop
the door
Select Cooling
Open
on
because it
and
Room Air Conditioner
can
adjusting
button to start the unit.
the remote control.
Operation or Healthy Dehumidification Operation.
Energy-Saving Cooling Mode button.
To cancel the Energy-Saving Cooling Mode, press the Energy-Saving Cooling Model
button and unit will operate in previous Mode(Cooling or Healty Dehumidification
Mode).
3. Press the
4.
save
Operating
Auto
Instructions
clean(Optional)
1. Whenever you press the Auto Clean button, Auto Clean Function will be reserved and cancelled.
2. Auto Clean function works before and after cooling or dehumidification mode. For details, refer
to the below points.
AUTO CLEAN
3. When the unit is started after the reservation of Auto Clean
indoor Fan is started after 20 seconds.
,the Cool Start function operates and
ENGLISH
4. When you press Start/Stop button to turn off the unit after the you have reserved Auto Clean
function, the air-conditioner circulates the indoor air in the Auto Clean mode with no more
Cooling or Dehumidification operation. For Cooling only model, it lasts for 30 minutes for Heat
pump model, for 16 minutes.
5. If you press the auto clean button
be cancelled.
again during the product operation
,
Auto Clean function will
NOTICE
This function is to
remove unpleasant smells from mold and other bacteria in the air-conditioner,
humidity automatically during humidly summer, which supplies the indoor with purified air.
Forced
and to
operation
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Cooling Model
Operating
mode
Indoor FAN
Speed
operation
During
the TEST
test
Cooling
High
High
Healthy
Temp. < 24°C
Dehumidification
Room
Temp. < 21°C
Heating
High
High
OPERATION, the unit operates in cooling mode
at
high speed fan, regardless
of
room
resets in 18 minutes.
operation,
if remote controller
If you want to use this
about 3 seconds.
If you want to
Heat pump Model
22°C2 2 °C2 3 °C2 4 °C
Test
temperature and
Power
button
Room Temp. ≥ 24°C2 1 °C ≤ Room
Cooling
Setting Temperature
During
remove
operation,
signal
is
open the front
received, the unit operates
panel upward
as
remote controller sets.
and Press the power button let it be
pressed
for
stop the operation, re-press the button.
Auto restart
In
the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
So there is no need of activating this function by pressing any key or button.
In the initial mode, the fan operates at a low speed and the compressor starts 2.5~3minutes later.
As the compressor starts, the fan speed also resumes its previous setting mode.
case
High
Speed
Helpful
information
Fan
and
speed
cooling capacity.
cooling capacity indicated in the specification is the value when the
fan speed is set to high, and the capacity will be lower at low or medium
fan speed.
High fan speed is recommended when you wish to cool the room quickly.
The
Owner's Manual
23
Maintenance and Service
Maintenance and Service
Indoor Unit
WARNING: Turn the
To
Supply
NOTICE
1.
clean, wipe with
the
Open
system off before cleaning.
soft, dry cloth. Do not use bleach
a
power must be disconnected before
upside
cleaning
or
abrasives.
the indoor unit.
of Front Panel
Front
panel
2. Put up the Front panel.
The hook of panel comes off.
Panel hook
3. Come down the
panel
and then
remove
the air filter.
Air filters
WARNING: Don't touch the PLASMA Filter
within 10 seconds after
grille,
4. Clean it wi
If it is very
a
it may
cause
soft brush and the
dirty,
opening
the inlet
electric shock.
vacuum
cleaner.
wash it with water.
5. Reinstall the air filter dried at the shade and then close
the
panel.
Air filters
Never
?
use
Could
?
followings:
cause
deformation and/or discoloration.
Volatile substances
Could
24
any of the
Water hotter than 40°C
damage
the surfaces of the air conditioner.
Room Air Conditioner
Powder
Gasoline
Maintenance and Service
Outdoor Unit
The heat
exchanger coils and panel vents of the outdoor
clogged with dirt or soot, the heat exchanger
and panel vents may be professionally steam cleaned.
unit should be checked
regularly.
If
Dirty or clogged coils will reduce the
operating efficiency of the system and
cause higher operating costs.
NOTICE
ENGLISH
(Rear)
Air intake
(Side)
Piping
vents
Drain Hose
Air outlet
vents
(Rear)
Air intake
(Side)
Air intake
Piping
vents
1.
Piping
vents
Drain Hose
Drain Hose
Air outlet
Air outlet
vents
vents
Filter
Cleaning
?
(Rear)
(Side)
Recomended
use
Open the upside
panel.
period
:
About 3 months
of Front
2. Put up the front panel.
The hook of panel comes off.
3. Remove air filter and then
out the
Nano
Front
4. Clean
the
panel
nano
vacuum
nano
plasma
pull
filter.
plasma filter
Panel
hook
plasma
filter with
cleaner.
5. Relocate dried
nano
plasma
filter at the shade and then
put
in air filter.
Nano
plasma filter
Owner's Manual
25
Maintenance and Service
When the air conditioner is not going to be used for a
When air conditioner is not
used for
going
to be
Operate
the air conditioner
on
unit.
(Refer to page
This will
dry
24 for
cleaning filters.)
out the internal mechanisms.
Turn off the circuit
the
again.
Clean the air filter and install it in the indoor
mode for 2 to
3hours.
?
time.
When the air conditioner is to be used
long time.
a
long
breaker, and disconnect
plug.
Check that the air inlet and outlet of the
indoor/outdoor unit
CAUTION:
are
not blocked.
Turn off the circuit
breaker when the air conditioner is not
goingtobeusedforalongtime.
Dirt may collect and may
cause a
fire.
Remove the batteries from the remote
control.
Operation Tips
Do not overcool the
room.
Keep
blinds
or
curtains
Keep the
closed.
This is not
good for the
electricity.
health
and wastes
Do not let direct sunshine enter
Adjust the
horizontal airflow direction to
room
when the air
operation.
ensure a
in the
Make
sure
that the doors
are
Avoid
doors and
opening
windows
to
keep
as
much
shut
as
Clean the air filter
regularly.
tight.
the cool air in the
room.
in the air filter
the
cooling
and
dehumidifying
every two weeks.
Room Air Conditioner
uniform
temperature
room.
Ventilate the
room
Since windows
reduces the airflow and lowers
effects. Clean at least
26
vertical and
occasionally.
Blockages
possible
temperature
the
conditioner is in
and windows
room
uniform.
once
in
it is
are
kept closed,
idea to open them
and ventilate the room now and
a
then.
good
Maintenance and Service
Troubleshooting
Check the
or
following points
before
requesting repairs
or
service.... If the fault
persists, please
contact your dealer
service center.
Case
The air conditioner does not
?
operate.
?
Explanation
See page
Have you made a mistake in timer operation?
Has the fuse blown or has the circuit breaker
21
been
The
room
has
a
peculiar
?
odor.
tripped?
Check that this is not
the
ENGLISH
-
a
damp
walls, carpet, furniture,
or
smell exuded
by
cloth items in the
-
room.
It
is
that condensation
seems
leaking
?
from the air
Condensation
occurs
when the airflow from
the air conditioner cools the
warm room
air.
-
conditioner.
Air conditioner does not
operate
for about 3 minutes
?
This is the
?
Wait about three minutes and
when restarted.
Does not cool
or
protector of the mechanism.
operation
will
heat
?
Is the air filter
dirty?
See air filter
cleaning
24
instructions.
effectively.
?
Has the
?
Are the indoor unit's air inlet
temperature been
set
incorrectly?
or
The air conditioner
is
?
For
a
-
noise that sounds like water
-This is the sound of freon
noisy.
12, 16
outlet vents
obstructed?
operation
-
begin.
flowing
flowing.
inside the
air conditioner unit.
?
For
noise that sounds like the
compressed
atmosphere.
-This is the sound of the dehumidifying water
being processed inside the air conditioning
air
a
releasing
into
-
unit.
Remote control
?
Are the batteries
faint,
?
Are the batteries inserted in the
or no
display is
display at all.
and
Crack sound is heard.
?
(-)
depleted?
opposite (+)
10
directions?
This sound is
generated by the
expansion/constriction of the front panel,
due to changes of temperature.
etc.
-
Owner's Manual
27
Memo
28
Room Air Conditioner
Download PDF