2
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors and windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block
the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
3
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
! WARNING
It can result in serious injury or death when the directions are ignored
! CAUTION
It can result in minor injury or product damage when the directions are ignored
! WARNING
• Installation or repairs by unqualified persons can result in hazards to you and others.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.
Installation
• Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
There is risk of fire or electric shock.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service
Center. Do not disassemble or repair the product. There is risk of fire or electric shock.
• Always ground the product. There is risk of fire or electric shock.
• Install the panel and the cover of control box securely. There is risk of fire or electric shock.
• Always install a dedicated circuit and breaker. Improper wiring or installation may cause fire or
electric shock
• Use the correctly rated breaker or fuse. There is risk of fire or electric shock.
• Do not modify or extend the power cable. There is risk of fire or electric shock.
• Do not install, remove, or re-install the unit by yourself (customer). There is risk of fire, electric
shock, explosion, or injury.
• Be cautious when unpacking and installing the product. Sharp edges could cause injury. Be
especially careful of the case edges and the fins on the condenser and evaporator.
• For installation, always contact the dealer or an Authorized Service Center. There is risk of
fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand. It may cause injury, accident, or
damage to the product.
• Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall with it, causing property damage, product failure, and personal injury.
• Do not let the air conditioner run for a long time when the humidity is very high and a door or
a window is left open. Moisture may condense and wet or damage furniture.
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
Operation
• Take care to ensure that power cable could not be pulled out or damaged during operation.
There is risk of fire or electric shock.
• Do not place anything on the power cable. There is risk of fire or electric shock.
• Do not touch(operate) the product with wet hands. There is risk of fire or electrical shock.
• Do not place a heater or other appliances near the power cable. There is risk of fire and electric shock.
• Do not allow water to run into electric parts. There is risk of fire, failure of the product, or electric shock.
• Do not store or use flammable gas or combustibles near the product. There is risk of fire or
failure of product.
• Do not use the product in a tightly closed space for a long time. Oxygen deficiency could
occur.
• When flammable gas leaks, turn off the gas and open a window for ventilation before turning
the product on. Do not use the telephone or turn switches on or off. There is risk of explosion
or fire
• If strange sounds, or smell or smoke comes from product. Turn the breaker off or disconnect
the power supply cable. There is risk of electric shock or fire.
• Stop operation and close the window in storm or hurricane. If possible, remove the product
from the window before the hurricane arrives. There is risk of property damage, failure of
product, or electric shock.
• Do not open the inlet grill of the product during operation.(Do not touch the electrostatic filter,
if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure.
• When the product is soaked (flooded or submerged), contact an Authorized Service Center.
There is risk of fire or electric shock.
• Be cautious that water should not enter the product. There is risk of fire, electric shock, or
product damage.
• Ventilate the product from time to time when operating it together with a stove, etc. There is
risk of fire or electric shock.
• Turn the main power off when cleaning or maintaining the product. There is risk of electric
shock.
• When the product is not to be used for a long time, disconnect the power supply plug or turn
off the breaker. There is risk of product damage or failure, or unintended operation.
• Take care to ensure that nobody should step on or fall onto the outdoor unit. This could result
in personal injury and product damage.
IMPORTANT SAFETY INSTRUCTIONS
5
• Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product.
• Install the drain hose to ensure that water is drained away properly. A bad connection may cause
water leakage.
• Keep level even when installing the product. To avoid vibration or water leakage.
• Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. It may cause a problem for your neighbors.
• Use two or more people to lift and transport the product. Avoid personal injury.
• Do not install the product where it will be exposed to sea wind (salt spray) directly. It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause
product malfunction or inefficient operation.
Operation
• Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft.) This could
harm to your health.
• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. There is risk of damage or loss of property.
• Do not block the inlet or outlet of air flow. It may cause product failure.
• Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. There is risk of fire, electric
shock, or damage to the plastic parts of the product.
• Do not touch the metal parts of the product when removing the air filter. They are very sharp! There
is risk of personal injury.
• Do not step on or put anyting on the product. (outdoor units) There is risk of personal injury and failure of product.
• Always insert the filter securely. Clean the filter every two weeks or more often if necessary. A dirty
filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
• Do not insert hands or other objects through the air inlet or outlet while the product is in operation.
There are sharp and moving parts that could cause personal injury.
• Do not drink the water drained from the product. It is not sanitary and could cause serious health issues.
• Use a firm stool or ladder when cleaning or maintaining the product. Be careful and avoid personal
injury.
• Replace all the batteries in the remote control with new ones of the same type. Do not mix old and
new batteries or different types of batteries. There is risk of fire or explosion
• Do not recharge or disassemble the batteries. Do not dispose of batteries in the fire. They may burn
or explode.
• If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water. Do not
use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other
health hazards.
• If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if
the batteries have leaked. The chemicals in batteries could cause burns or other health hazards.
ENGLISH
! CAUTION
Installation
6
TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
2
TIPS FOR SAVING ENERGY
18 MAINTENANCE AND
3
IMPORTANT SAFETY INSTRUCTIONS
18
19
20
7
BEFORE USE
7
7
7
7
Preparing for operation
Usage
Cleaning and maintenance
Service
8
PRODUCT INTRODUCTION
8
9
11
13
Name of parts
Indoor unit controls and indicators
Wireless remote controller
Remote control preparation
14 OPERATING INSTRUCTIONS
14
14
14
14
15
15
15
15
16
16
16
17
Cooling Mode
Heating Mode
Airflow Setting
Fan Speed Setting
Dehumidification Mode
Power Cooling/Heating Mode
Fan Mode
Simple Reservation
Defrost Mode
Child Lock Operation Function
Auto Dry Function
Auto Restart Operation
SERVICE
20
Indoor Unit
Operation Tips
Troubleshooting Tips! Save time and
money!
Call the service immediately in the following situations
BEFORE USE
7
Preparing for operation
• Contact an installation specialist for installation.
• Use a dedicated circuit.
Usage
• Being exposed to direct airflow for an extended period of time could be hazardous to your
health. Do not expose occupants, pets, or plants to direct airflow for extended period of time.
• Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves
or other heating devices.
• Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
• Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
• Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
• When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is
accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
ENGLISH
BEFORE USE
8
PRODUCT INTRODUCTION
ENGLISH
PRODUCT INTRODUCTION
Name of parts
Indoor unit
1
2
3
4
5
6
Left/Right Airflow Control Louver
Up/Down Airflow Control Louver
Display Panel
Air filter
Air Inlet
Control Box
1
2
3
4
5
6
PRODUCT INTRODUCTION
ENGLISH
Indoor unit controls and indicators
Heat Pump
1
3
5
6
4
2
11
MODE
7
8
1. Timer
2. Defrosting operation lamp
3. Cooling operation lamp
4. Heating operation lamp
5. Room temp. / Set temp. display
6. Indoor fan speed lamp
7. Start/Stop button
8. Operation mode selection button
9. Room temperature setting button
10. Indoor fan speed button
11. Signal receptor
9
9
10
10 PRODUCT INTRODUCTION
ENGLISH
Cooling only
1
3
5
6
4
2
11
MODE
7
8
1. Timer
2. Dehumidification operation lamp
3. Cooling operation lamp
4. Fan mode operation lamp
5. Room temp. / Set temp. display
6. Indoor fan speed lamp
7. Start/Stop button
8. Operation mode selection button
9. Room temperature setting button
10. Indoor fan speed button
11. Signal receptor
9
10
PRODUCT INTRODUCTION
11
ENGLISH
Wireless remote controller
Heat Pump
1
No.
Control
panel
1
r
|
Power ON/OFF button : Operation will
start when this button is pressed, and
stop when the button is pressed again.
4
Indoor fan speed button : To select the
2
5
3
4
6
2
7
8
9
3
10
11
4
12
13
5
6
Temperature setting button
A
B
Cooling button
Heating button
Auto dry button : If setting this function,
evaporator will be automatically dried before turning off the air conditioner.
X
Child lock button : In operation this function, display key will be locked and air
conditioner indicates “CL” on its display
panel.
Fan mode button
9
10
Remote controller operation lamp
FAN SPD desired fan speed.
7
8
Description
IJ
Air flow direction button(Up/down,
Left/right) : Adjust air flow direction vertically or horizontally.
11
Power cooling/heating mode button :
Powerful cooling/heating are performed
within short time
12
ON/OFF timer setting button : Set the
time of starting or stopping
13
Timer cancel button
Handling the remote control
- Aim at the signal receptor on the floor standing type air
conditioner when operating.
- Block a strong light over the signal receptor with a curtain
or etc. so as to prevent the abnormal operation. (ex: electronic quick start, ELBA, inverter type fluorescent lamp)
- Be sure that there are no obstructions between the remote control and the signal receptor.
- Do not drop or throw the remote control.
- Do not place the remote control in a location exposed to
direct sunlight, or next to a heating unit, or other heat
source.
12 PRODUCT INTRODUCTION
ENGLISH
Cooling only
No.
1
Control
panel
Remote control operation lamp
1
2
5
3
4
6
7
8
9
10
11
12
13
2
|
3
4
FAN SPD
4
5
Description
Power ON/OFF button : Operation will
start when this button is pressed, and
stop when the button is pressed again.
Indoor fan speed button : To select the
desired fan speed.
Temperature setting button
A
Cooling button
Auto dry button : If setting this function,
evaporator will be automatically dried before turning off the air conditioner.
6
7
D
Dehumidification button : Can effectively
remove humidity when at the time of
rainy season or high humidity.
8
X
Child lock button : In operation this function, display key will be locked and air
conditioner indicates “CL” on its display
panel.
9
Fan mode button
10
Air flow direction button(Up/down,
Left/right) : Adjust air flow direction vertically or horizontally.
11
Power cooling mode button : Powerful
cooling is performed
12
ON/OFF timer setting button : Set the
time of starting or stopping
13
Timer cancel button
Handling the remote control
- Aim at the signal receptor on the floor standing type air
conditioner when operating.
- Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation. (ex:
electronic quick start, ELBA, inverter type fluorescent
lamp)
- Be sure that there are no obstructions between the remote control and the signal receptor.
- Do not drop or throw the remote control.
- Do not place the remote control in a location exposed to
direct sunlight, or next to a heating unit, or other heat
source.
PRODUCT INTRODUCTION 13
ENGLISH
Remote control preparation
How to mount onto a wall
1 Use the screws to secure the holder to the
wall.
2 To insert the remote control to the holder.
- Do not use rechargeable batteries such batteries are different from standard dry cells in
shape, dimensions, and performance.
- Change the batteries with a new one if the
remote control does not work properly after
using for an extended period of time.
! CAUTION
How to insert batteries
1 Remove the cover from the back of the remote controller.
- Slide the cover according to the arrow direction.
2 Insert two batteries.
- Be sure that the (+) and (-) directions are
correct.
- Be sure that both batteries are new.
3 Re-attach the cover.
- Slide the cover into back position.
• When not using remote controller for a
long time, flowing of dry cell liquid may
cause the failure of product, therefore,
remove all dry cells.
• When replacing dry cell (AAA), replace
two of them all with new ones, and if remote controller is not operated properly
even after replacing the dry cells (AAA),
request the service.
• Do not disassemble or re-charge the
used dry cells, and do not throw away
those at the location with heat of fire or
hot air. There will be the danger of explosion.
14 OPERATING INSTRUCTIONS
ENGLISH
OPERATING INSTRUCTIONS
Cooling Mode
1 Press | button to turn on the indoor.
2 Press a button to select Cooling opera-
tion mode.
- When canceling operating, press | button once more.
3 Adjust the desired temperature by pressing (
) buttons.
- If desired temperature is higher than
room temperature, cooling cannot be conducted.
- Set the temperature lower than the room
temperature
- Setting Temp Range : 18 °C~30 °C.
!
NOTE
What is 3 minutes delay function?
The reason that cold wind is not coming out
when operating the unit after turning off the
cooling is because of the function to protect
compressor. Cold wind will be coming out
when compressor is operated after 3 minutes.
Heating Mode
Heat Pump
1 Press | button to turn on the indoor.
Airflow Setting
We can simply adjust the desired airflow direction.
Up/Down Airflow Direction Control
1 Press | button to turn on the indoor.
2 Press I button and the louvers will
swing up and down.
3 Press I button again to set the horizontal
louver at the desired airflow direction.
Left/Right Airflow Direction Control
1 Press | button to turn on the indoor.
2 Press J button and the louvers will
swing left and right.
3 Press J button again to set the vertical
louver at the desired airflow direction.
<Airflow Setting Table>
Symbol
Description
I
Up·Down : Vane move from up to
down automatically and continuously
: Vane move from left to
J Left·Right
right automatically and continuously
2 Press d button to select Heating opera-
tion mode.
- When canceling operation, press | button once more.
3 Adjust the desired temperature by pressing (
) buttons.
- If desired temperature is lower than room
temperature, heating cannot be conducted.
- Set up desired temperature higher than
the room temperature
- Setting Temp Range : 16 °C~30 °C.
!
NOTE
Preheating operation
When conducting heating operation at the
condition of low outdoor temperature, the
case that wind is not coming out for several
minutes under the state of lighting of defrost lamp may be occurred. This is the preheating stage to supply warm wind which
will be supplied subsequently in short time.
Fan Speed Setting
1 Press | button to turn on the indoor.
2 Press
button to select fan speed.
- You can select the fan speed in four
steps Low, Mid, High, Super High.
Each time the button is pressed, the fan
speed mode is shifted.
- Air flow rate can be selected during the
cooling, heating, dehumidification, blowing, and auto operation mode.
OPERATING INSTRUCTIONS 15
Cooling only
In rainy season or high humidity climate, it is
possible to operate simultaneously dehumidifier and cooling mode to remove humidity effectively.
1 Press | button to turn on the indoor.
2 Press c button to select dehumidification
mode
- Room temperature will be displayed after
desired temperature is indicated at display section for about 5 seconds.
Power Cooling/Heating Mode
Strong cooling/heating will be conducted in
short time.
Heat Pump
1 Press | button to turn on the indoor unit.
2 Press
button on remote controller to
circulate indoor air.
- When canceling operation, press
button once more.
- During fan mode, outdoor fan and
compressor will not be operated.
- During fan mode, indoor unit turns on the
fan speed lamp and room temperature
lamp of its display panel.
Simple Reservation
Turning ON reservation mode
1 Press | button to turn on the indoor.
This function is able to turn on unit after a setting time.
2 Press
button to operate power cooling/heating mode.
1 When the unit is turned off, adjust desired
- When power (cooling/heating) button is
pressed during cooling/dehumidification
mode, power cooling will be operated.
In power cooling mode, desired temperature is set to 18°C and the horizontal louver is fixed at the highest position.
- When power (cooling/heating) button is
pressed during heating operation, power
heating will be operated.
In power heating mode, desired temperature is set to 30°C and the horizontal louver is fixed at the lowest position.
- Up to the maximum of 24 hours can be
selected.
Fan Mode
Cooling only
1 Press | button to turn on the indoor unit.
2 Press
button to circulate indoor air.
- When canceling operation, press
button once more.
- During fan mode, outdoor fan and compressor will not be operated.
- During fan mode, indoor unit turns on the
fan mode lamp, room temperature lamp,
and fan speed lamp of its display panel.
setting time with
button.
Turning OFF reservation mode
This function is able to turn off unit after a setting time.
1 When the unit is turned on, adjust desired
setting time with
button.
- Up to the maximum of 7 hours can be selected.
!
NOTE
After performing the setting, if corresponded
setting button is pressed once, remaining setting time will be displayed, and if it is pressed
once again, corresponded setting function will
be cancelled. (same function as
) Remaining
setting time will be displayed with the unit of 1
hour.
ENGLISH
Dehumidification Mode
16 OPERATING INSTRUCTIONS
ENGLISH
Defrost Mode
Heat Pump
3 Press the
and high
simultaneously
for 3 seconds again. The unit will respond
with beep. child lock operation will removed
1 During defrost operation, M will be indicated at display section of indoor.
MODE
MODE
2 During heating operation, if outside temperature is low and humidity is high, heating capability will be deteriorated as frost is
generated at outdoor unit, therefore, the
frost will be removed by performing defrost operation.
3 When indoor and outdoor unit fans are automatically stopped and defrost operation
is completed, preheating for heating cycle
will automatically be started.
* Heating operation will be started in a little time.
!
NOTE
What is preheating function for heating cycle?
• During the heating, indoor fan will not be operated until indoor tubing temperature becomes
more than 22 °C, therefore, this is the function
to block the discharge of cold wind.
• During the preheating for heating cycle, heating cannot be performed.
• During defrost operation, vapor can be generated at outdoor side, and this is not a failure
because it is the operation to remove frost.
Child Lock Operation Function
1 Press the
and high
simultaneously
for 3 seconds. Or press the X button on
remote control.
2 During child lock operation,
- Whenever you press any button on display panel, it will immediately display
"CL", which means display panel is
locked.
- All the button on the indoor unit display
panel will not work.
- But the button on the remote controller
will be operated.
Auto Dry Function
1 Auto dry function can be setted/released
by manipulating indoor unit button or remote control.
2 When pressing the
button after setting
the function, evaporator in indoor unit will
be automatically dried as showing counting
00 to 99 on its display panel .
3 After indicating 99 on the display panel,
the unit will be automatically turned off.
* Auto dry function is released at initial
state as standard.
For Setting Auto Dry Function
If manipulating indoor unit, press the
button and
button simultaneously for 3
seconds.
If manipulating remote control for Cooling
Only model, press
button.
The indoor unit will respond with beep once
and indicate “SC” on its display panel. Then
Auto dry function will be set.
MODE
For Releasing Auto Dry Function
If manipulating indoor unit, press the
button and
button simultaneously for 3
seconds.
If manipulating remote control, press
button.
The indoor unit will respond with beep twice
and Auto dry function will be removed.
MODE
MODE
OPERATING INSTRUCTIONS 17
When power is supplied again after unit operation has been stopped because of interruption of power supply due to outage or other
causes, auto re-operation will be performed by
remembering previous setting.
- When power is supplied, outdoor unit operation will be started within 3 minutes.
1 Auto Restart Operation can be established/released by manipulating indoor unit
button.
* When initial state, Auto Restart Operation will be set up as standard.
For Releasing Restart Operation
Press the
,
,
,
taneously for 3 seconds.
(4 buttons) simul-
The unit will respond with beep and Restart
Operation will be removed.
For Setting Restart Operation
After funtion release, Press the
,
,
,
(4 buttons) simultaneously for 3 seconds.
The unit will respond with beep and restart
operation will be setted.
MODE
ENGLISH
Auto Restart Operation
18 MAINTENANCE AND SERVICE
ENGLISH
MAINTENANCE AND SERVICE
Filter Cleaning
Indoor Unit
Grille, Case and Remote Control
- Turn the system off before cleanining, To
clean, wipe with a soft, dry cloth. Do not use
bleach or abrasives.
!
Please clean it once in a week.
1 Remove the Air filters.
- Take hold of the tab and pull slightly forward to remove the filter.
! CAUTION
NOTE
Supply power must be disconnected before cleaning the indoor unit.
When the air filter is to be removed, do
not touch the metal parts of the indoor
unit. It may cause an injury.
Air Filters
The air filters behind the front grille should be
checked and cleaned once every 2 weeks or
more often if neccessary.
- Never use any of the followings:
Water hotter than 40 °C.
Could cause deformation and/or discoloration.
Volatile substances.
Could damage the surfaces of the air conditioner.
2 Clean dirt from the air filter using a vacuum
cleaner or washing with water.
- If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
SI
Be
n zene
N NER
SCO
U RIN G
C LB
A R GER
- If hot water (40 °C or more) is used, it
may be deformed.
3 After washing with water, dry well in the
shade.
- Do not expose the air filter to direct sunlight or heat from a fire when drying it.
4 Install the air filter.
MAINTENANCE AND SERVICE 19
1 Operate the air conditioner at the following
settings for 2 to 3 hours.
- Type of operation: Fan operation mode.
- This will dry out the internal mechanisms.
When the air conditioner is to be
used again.
1 Clean the air filter and install it in the indoor unit.
2 Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
3 Check that the ground wire is connected
! CAUTION
correctly. It may be connect to the indoor
unit side.
Turn off the breaker when the air conditioner is not going to be used for a long
time.
Dirt may collect and may cause a fire.
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6 % of the electricity used to operate the air conditioner will
be wasted.
Operation Tips
Do not overcool/overheat the
room.
This is not good for the health
and wastes electricity.
Keep blinds or curtains closed.
Do not let direct sunshine
enter the room when the air
conditioner is in operation.
Keep the room temperature
uniform.
Adjust the vertical and horizontal airflow direction to ensure a
uniform temperature in the
room.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and windows as much as possible to
keep the cool air in the room.
Clean the air filter regularly.
Blockages in the air filter reduces the airflow and lowers
the cooling and dehumidifying
effects. Clean at least once
every two weeks.
Ventilate the room occasionally.
Since windows are kept
closed, it is a good idea to
open them and ventilate the
room now and then.
ENGLISH
When air conditioner is not going
to be used for a long time.
20 MAINTENANCE AND SERVICE
ENGLISH
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist,
please contact your dealer.
The air conditioner
The room has a pecudoes not operate.
liar odor.
- Have you made a
- Check that this is not
mistake in timer oper- a damp smell exuded
ation?
by the walls, carpet,
furniture or cloth
- Has the fuse blown
items in the room.
or has the circuit
breaker been tripped?
It seems that condensation is leaking from
the air conditioner.
- Condensation occurs
when the airflow
from the air conditioner cools the warm
room air.
Air conditioner does
not operate for about 3
minutes when restart.
- This is the protector
of the mechanism.
- Wait about three minutes and operation
will begin.
Does not cool or heat
effectively.
- Is the air filter dirty?
See air filter cleaning
instructions.
- The room may have
been very hot when
the room air conditioner was first turned
on. Allow time for it
to cool down.
- Has the temperature
been set incorrectly?
- Are the indoor unit's
air inlet or outlet
vents obstructed?
Crack sound is heard.
- This sound is generated by the expansion/ constriction of
the front panel, etc.
due to changes of
temperature.
Remote control display
is faint, or no display at
all.
- Are the batteries depleted?
- Are the batteries inserted in the opposite
(+) and (-) directions?
Filter sign lamp (LED)
is ON.
- Cleaning the filter,
press the Timer button and ◀ button of
wired remote controller at the same
time for 3 sec.
The error code is occurred after lightning
struck
- This product has
been applied to the
over current protection circuit.
Error can occur, but it
is normal behavior.
After few minutes, It
will operate normally.
The air conditioner operation is noisy.
- For a noise that
sounds like water
flowing.
* This is the sound of
freon flowing inside
the air conditioner
unit.
- For a noise that
sounds like the compressed air releasing
into atmosphere.
-This is the sound of
the dehumidifying
water being
processed inside the
air conditioning unit.
Call the service immediately in the following situations
1 Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and turn the
2
3
4
5
breaker off. Never try to repair by yourself or restart the system in such cases.
Main power cord is too hot or damaged.
Error code is generated by self diagnosis.
Water leaks from indoor unit even if the humidity is low.
Any switch, breaker (safety, earth) or fuse fails to work properly
User must carry routine checkup & cleaning to avoid unit’s poor performance.
In case of special situation, the job must be carried out by service person only.