TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block
the air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
IMPORTANT SAFETY INSTRUCTIONS
3
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
! WARNING
It can result in serious injury or death when the directions are ignored
! CAUTION
It can result in minor injury or product damage when the directions are ignored
! WARNING
• Always ground the product. There is a risk of electric shock.
• Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and fuse.
There is risk of fire or electric shock .
• Do not use a multi consent. Always use this appliance on a dedicated cicuit and breaker. Otherwise it can cause electric shock or fire.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service
Center. Do not disassemble or repair the product by yourself. There is risk of fire or electric
shock.
• Always ground the product as per the wiring diagram. Do not connect the ground wire to gas
or water pipes lightening rod or telephone ground wire. There is risk of fire or electric shock.
• Install the panel and the cover of control box securely. There is risk of fire or electric shock
due to dust , water etc.
• Use the correctly rated breaker or fuse. There is risk of fire or electric shock.
• Do not modify or extend the power cable. If the power cable or cord has scrathes or skin
peeled off or deteriorated then it must be replaced. There is risk of fire or electric shock.
• For installation, removal or reinstall , always contact the dealer or an Authorized Service Center. There is risk of fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand. Be sure that the installation area
does not deteriorate with age. It may cause product to fall.
• Never install the outdoor unit on a moving base or a place from where it can fall down. The
falling outdoor unit can cause damage or injury or even death of a person.
• When the product is soaked (flooded or submerged) in water , contact an Authorized Service
Center for repair before using it again. There is risk of fire or eletric shock.
• Be sure to check the refrigerant to the used. Please read the label on the product. Incorrect
refrigerant used can prevent the normal operation of the unit.
• Don't use a power cable, a plug or a loose socket which is damaged. Otherwise it may
cause a fire or electrical shock.
• Do not touch , operate, or repair the product with wet hands. Hold the plug by hand when
taking out. There is risk of electric shock or fire.
• Do not place a heater or other heating appliances near the power cable. There is risk of fire
and electric shock.
• Do not allow water to run into electric parts. Install the unit away from water sources. There
is risk of fire, failure of the product, or electric shock.
• Do not store or use or even allow flammable gas or combustibles near the product. There is
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
4
IMPORTANT SAFETY INSTRUCTIONS
ENGLISH
risk of fire.
• Indoor/outdoor wiring connections must be secured tightly and the cable should be routed
properly so that there is no force pulling the cable from the connection terminals. Improper or
loose connections can cause heat generation or fire.
• Safely dispose off the packing materials. Like screws, nails, batteries, broken things etc after
installation or svc and then tear away and thraw away the plastic packaging bags. Children
may play with them and cause injury.
• Make sure to check that the power cable plug is not dirty, loose or broken and then only insert the plug completely. Dirty, loose or broken power plug can cause electric shock or fire.
• In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical components. Be sure to discharge the capacitor completely before conducting the repair work. An
charged capacitor can cause electrical shock.
• When installing the unit, use the installation kit provided with the product. Otherwise the unit
may fall and cause severe injury.
• Be sure to use only those parts which are listed in the svc parts list. Never attempt to modify the equipment. The use of inappropriate parts can cause an electrical shock, excessive
heat generation or fire.
• Do not use the product in a tightly closed space for a long time. Perform ventilation regularly.
Oxygen deficiency could occur and hence harm your health.
• Do not open the front grille of the product during operation. (Do not touch the electrostatic filter, if the unit is so equipped.) There is risk of physical injury, electric shock, or product failure.
• If strange sounds, smell or smoke comes from product.Immediately turn the breaker off or
disconnect the power supply cable. There is risk of electric shock or fire.
• Ventilate the product room from time to time when operating it together with a stove, or
heating element etc. Oxygen deficiency can occur and hence harm your health.
• Turn the main power off and unplug the unit when cleaning or repairing the product. There is
risk of electric shock.
• When the product is not to be used for a long time, disconnect the power supply plug or turn
off the breaker. There is risk of product damage or failure, or unintended operation.
• Take care to ensure that nobody especially kids could step on or fall onto the outdoor unit.
This could result in personal injury and product damage.
• Take care to ensure that power cable could not be pulled out or damaged during operation.
There is risk of fire or electric shock.
• Do not place ANYTHING on the power cable. There is risk of fire or electric shock.
• Do not plug or unplug the power supply plug to turn the unit ON/OFF. There is risk of fire or
electric shock.
• When flammable gas leaks, turn off the gas and open a window for ventilation before turn the
product on. Do not use the telephone or turn switches on or off. There is risk of explosion or
fire.
! CAUTION
• Two or more people must lift and transport the product. Avoid personal injury.
• Do not install the product where it will be exposed to sea wind (salt spray) directly. It may
cause corrosion on the product.
• Install the drain hose to ensure that the condensed water is drained away properly. A bad
connection may cause water leakage.
• Keep level even when installing the product. To avoid vibration or noise.
• Do not install the product where the noise or hot air from the outdoor unit could damage or
disturb the neighborhoods. It may cause a problem for your neighbors and hence dispute.
IMPORTANT SAFETY INSTRUCTIONS
5
ENGLISH
• Always check for gas (refrigerant) leakage after installation or repair of product. Low refrigerant levels may cause failure of product.
• Do not use the product for special purposes, such as preserving foods, works of art, etc. It is
a consumer air conditioner, not a precision refrigeration system. There is risk of damage or
loss of property.
• Do not block the inlet or outlet of air flow. It may cause product failure.
• Use a soft cloth to clean. Do not use harsh detergents, solvents or splashing water etc. There
is risk of fire, electric shock, or damage to the plastic parts of the product.
• Do not touch the metal parts of the product when removing the air filter. There is risk of personal injury.
• Do not step on or put anyting on the product. (outdoor units) There is risk of personal injury
and failure of product.
• Always insert the filter securely after cleaning. Clean the filter every two weeks or more often
if necessary. A dirty filter reduces the efficiency.
• Do not insert hands or other objects through the air inlet or outlet while the product is operating. There are sharp and moving parts that could cause personal injury.
• Be cautious when unpacking and installing the product. Sharp edges could cause injury.
• If the refrigerant gas leaks during the repair, do not touch the leakaing refrigerant gas. The refrigernat gas can cause frostbite (cold burn)
• Do not tilt the unit when removing or uninstalling it. The condensed water inside can spill .
• Do not mix air or gas other than the specified refrigerant used in the system. If air enters the
refrigerant system, an excessively high pressure results, causing equipment damage or injury.
• If the refrigerant gas leaks during the installation, ventilate the area immediately. Otherwise it
can be harmfull for your health.
• Dismantling the unit, treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards. Replace the all batteries in the remote control
with new ones of the same type. Do not mix old and new batteries or different types of batteries. There is risk of fire or product failure.
• Do not recharge or disassemble the batteries. Do not dispose off batteries in a fire. They may
burn or explode.
• If the liquid from the batteries gets onto your skin or clothes, wash it well with clean water.
Do not use the remote if the batteries have leaked. The chemicals in batteries could cause
burns or other health hazards.
• If you eat the liquid from the batteries, brush your teeth and see doctor. Do not use the remote if the batteries have leaked. The chemicals in batteries could cause burns or other
health hazard.
• Do not let the air conditioner run for a long time when the humidity is very high and a door or
a window is left open. Moisture may condense and wet or damage furniture.
• Do not expose your skin or kids or plants to the cool or hot air draft. This could harm to your
health.
• Do not drink the water drained from the product. It is not sanitary and could cause serious
health issues.
• Use a firm stool or ladder when cleaning, maintaining or repairing the product at an height.
Be careful and avoid personal injury.
6
TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
18
Auto Changeover Mode - Setting the
Mode Change Temperature
19
Airflow Setting
IMPORTANT SAFETY INSTRUCTIONS
19
Celsius/Fahrenheit Switching
20
Temperature Setting/Room Temperature checking
7
BEFORE USE
21 SUB FUNCTION
7
Preparing for operation
21
Plasma Purification(Optional)
7
Usage
21
Auto Clean (Optional)
7
Cleaning and maintenance
22
Smart Clean (Optional)
7
Service
23
LCD Luminosity Control (Optional)
PRODUCT INTRODUCTION
23
Celsius/Fahrenheit Switching
23
Electric heater (Optional)
24
Individual vane angle control (Optional)
2
3
8
TIPS FOR SAVING ENERGY
8
Name and function of parts
8
Operation Indication Lamps
25 TIMER
9
Wired Remote Controller (Accessory)
25
Setting the Current Time
10
Wireless Remote Controller
25
Sleep Timer Setting
25
On Timer Setting
26
Off Timer Setting
26
To cancel the Timer Setting
11 OPERATING INSTRUCTION
11
How to insert the Batteries
11
Wireless Remote Controller Maintenance
11
Operating Method
12 OWNER'S INSTRUC-
27 MAINTENANCE AND
SERVICE
27
Indoor Unit
28
Purifying filter(Optional)
TION
29
Operation Tips!
12
Cooling Mode - Standard Operation
29
12
Cooling Mode - Power Cooling
When the air conditioner is not
going....
13
Heating Mode
30
Troubleshooting Tips! Save time and
money!
14
Dehumidification Mode
30
15
Fan Mode
Call the service immediately in the following situations
16
Auto Operation Mode
17
Auto Changeover Mode
BEFORE USE
7
Preparing for operation
• Contact an installation specialist for installation.
• Use a dedicated circuit.
Usage
• Being exposed to direct airflow for an extended period of time could be hazardous to your
health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
• Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves
or other heating devices.
• Do not use this air conditioner for non-specified special purposes (e.g. preserving precision devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
• Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
• Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
• When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates at a very high speed during operation. There is a possibility of injury if the unit’s power is
accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
ENGLISH
BEFORE USE
PRODUCT INTRODUCTION
8
ENGLISH
PRODUCT INTRODUCTION
Name and function of parts
6 7
2
1
5
44
3
8
1
2
3
4
5
6
7
8
Indoor unit
Outdoor unit
Remote controller
Inlet air
Discharge air
Refrigerant piping, connection electric wire
Drain pipe
Ground wire
Wire to ground outdoor unit to prevent electrical shocks.
Operation Indication Lamps
On/Off : Lights up during the system operation.
Filter Sign : Lights up after 2400 hours from the time of first operating unit.
Timer : Lights up during Timer operation.
Defrost Mode : Lights up during Defrost Mode or Hot Start operation.
(Heat pump model only)
Forced operation : To operate the unit when the remote control can't be used for
any reason.
PRODUCT INTRODUCTION
1 OPERATION INDICATION SCREEN
2 SET TEMPERATURE Button
1
3 FAN SPEED Button
10
4 ON/OFF Button
9
8
2
3
7
4
11
12
13
5
6
14
5 OPRATION MODE SELECTION Button
6 WIRELESS REMOTE CONTROLLER RECEIVER
• Some products don't receive the wireless
signals.
7 AIR FLOW Button
8 SUBFUNCTION Button
15
9 FUNCTION SETTING Button
10 VENTILATION Button
11 RESERVATION
Please attach the inform label inside of the door.
Please choose proper language depend on your
country.
12 UP,DOWN,LEFT,RIGHT Button
• To check the indoor temperature, press
button
.
13 ROOM TEMPERATURE Button
14 SETTING/CANCEL Button
15 EXIT Button
h Some functions may not be operated and displayed depending on the product type.
!
NOTE
• Display temperature can be different from actual room temperature if the remote controller is
installed at the place where sun-rays are falling directly or the place nearby heat source.
• The actual product can be different from above contents depending upon model type.
• When using simultaneous operation system, whenever press remote controller button, system
will approximately operate after 1~2 minutes.
ENGLISH
Wired Remote Controller (Accessory)
9
10 PRODUCT INTRODUCTION
ENGLISH
Wireless Remote Controller
1 VANE ANGLE Button
Used to set each vane angle.
2 FUNCTION SETTING Button
1
2
3
10
11
12
4
13
5
6
14
7
8
15
16
9
17
Operation Mode
Cooling Mode
Auto Mode or Auto Changeover
Dehumidification mode
Heating Mode
Fan Mode
• Cooling Model(
), Heat Pump Model(
)
Used to set or clear Auto Clean, Smart
Clean, Electric heater or Individual vane
angle control.
3 ON/OFF Button
Used to turn on/off the unit.
4 JET COOL Button
Speed cooling operates super high fan
speed.
5 LEFT/RIGHT AIRFLOW Button (OPTIONAL)
Used to set the desired left/right(horizontal)
airflow direction.
6 UP/DOWN AIRFLOW Button
Used to stop or start louver movement and
set the desired up/down airflow direction.
7 ON TIMER Button
Used to set the time of starting operation.
8 SLEEP TIMER Button
Used to set the time of sleeping operation.
9 SET / CLEAR Button
Used to set/clear the timer.
Used to set the current time(if it input for
3sec.)
10 PLASMA Button (OPTIONAL)
Used to start or stop the plasma-purification
function.
11 ROOM TEMPERATURE SETTING Button
Used to select the room temperature.
12 OPERATION MODE SELECTION Button
Used to select the operation mode.
13 INDOOR FAN SPEED SELECTION Button
Used to select fan speed in four steps low,
medium, high and chaos.
14 ROOM TEMPERATURE CHECKING Button
Used to check the room temperature.
15 OFF TIMER Button
Used to set the time of stopping operation.
16 TIMER SETTING(Up/Down)/LIGHT Button
Used to set the timer.
Used to adjust the brightness.(if it is not
time adjust mode)
17 RESET Button
Used to reset the remote controller.
OPERATING INSTRUCTION
11
ENGLISH
OPERATING INSTRUCTION
How to insert the Batteries
1 Remove the battery cover by pulling it according to the arrow direction.
2 Insert new batteries making sure that the
(+) and (-) of battery are installed correctly.
3 Reattach the cover by sliding it back into
position.
Wireless Remote Controller
Maintenance
1 Choose a suitable place where its safe &
easy to reach.
2 Fix the holder to wall etc with the supplied
screws firmly.
3 Slide the remote controller inside the
holder.
!
!
NOTE
• Always use/replace both batteries of
same type.
• If the system is not to be used for a
long time, remove the batteries to save
their working life.
• If the display screen of remote controller starts, fading replace both of the
batteries.
NOTE
• Remote controller should never be exposed to direct sunlight.
• Signal transmitter & receiver should always be clean for proper communication. Use a soft cloth to clean them.
• In case some other appliances also get
operated with remote control, change
their position or consult your serviceman.
Operating Method
1 The signal receiver is inside the unit.
2 Aim the remote controller towards the unit
to operate it. There should not be any
blockage in between.
12 OWNER'S INSTRUCTION
ENGLISH
OWNER'S INSTRUCTION
Cooling Mode - Standard Operation
1
Press the ON/OFF button.
The unit will respond with beep sound.
2
Press MODE button to select Cooling Mode.
3
Set the desired temperature by pressing
TEMP button.
Press ROOM TEMPERATURE CHECKING
button to check the room temperature.
When setting the desired temperature is
higher than room temperature, cooling
wind isn’t blow out.
* Setting Temp. Range : 18~30 °C(64~86 °F)
To raise the temperature
To lower the temperature
Cooling Mode - Power Cooling
1
Press the ON/OFF button.
The unit will respond with beep sound.
2
Press MODE button to select Cooling Mode.
3
Press the JET COOL button. The unit will operate in
super high fan speed in cooling mode.
* Wall mounted models operate power cooling mode
for 30 minutes.
4
To cancel the Power cooling Mode press the Jet Cool button or the
fan button or the room temperature setting button again and the
unit will operate in high fan speed in cooling mode.
or
or
OWNER'S INSTRUCTION 13
ENGLISH
Heating Mode
This Function is only for H/P model.
1
Press the ON/OFF button.
The unit will respond with beep sound.
2
Press MODE button to select Heating Mode.
3
Set the desired temperature by pressing TEMP button.
Press ROOM TEMPERATURE CHECKING button to check the
room temperature.
When setting the desired temperature is lower than room
temperature, heating wind isn’t blow out.
To raise the temperature
To lower the temperature
4
* Setting Temp. Range in
Heating Mode :
16~30 °C (60 °F~86 °F)
Set the fan speed again. You can select the fan
speed in four steps–low, medium, high, or chaos.
Each time the button is pressed, the fan speed
mode is shifted.
14 OWNER'S INSTRUCTION
ENGLISH
Dehumidification Mode
!
1
Press the ON/OFF button.
The unit will respond with beep sound.
2
Press MODE button to select Dehumidification Mode.
3
Set the fan speed. You can select the fan speed
in four steps - low, medium, high, or chaos.
Each time the button is pressed, the fan speed
mode is shifted.
NOTE
During Dehumidification Mode
- If you select the dehumidification mode on the operation selection button, the indoor unit starts to
run the dehumidification function, automatically setting the room temp. and air volume to the best
condition for dehumidification based on the sensed room temp.
In this case, the setting temp. is not displayed in the Remote Controller and you are not able to
control the room temp. either.
- During the healthy dehumidification function, the air volume is automatically set according to the
algorithm responding to the current room temp. and makes the room condition healthy and comfortable even in the high humidity season.
OWNER'S INSTRUCTION 15
ENGLISH
Fan Mode
!
1
Press the ON/OFF button.
The unit will respond with beep sound.
2
Press MODE button to select Fan Mode.
3
Set the fan speed again. You can select the fan
speed in four steps–low, medium, high, or
chaos. Each time the button is pressed, the fan
speed mode is shifted.
NOTE
• Natural Wind by the chaos Logic
For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to
chaos mode. In this mode, the wind blows like natural breeze by automatically changing fan
speed according to the chaos logic.
• During Fan Mode
The outdoor compressor doesn't work.
Have a function to circulate the indoor as it sends out the air that doesn't have much temperature difference with indoor.
16 OWNER'S INSTRUCTION
ENGLISH
Auto Operation Mode
1
Press the ON/OFF button.
The unit will respond with beep sound.
2
Press MODE button to select Auto Operation
Mode.
3
Set the desired temperature.
<For Cooling Model>
The temperature and fan speed are automatically set by the
electronic controls based on the actual room temperature.
If you feel hot or cold, press TEMPERATURE SETTING buttons
for more cooling or heating effect.
You cannot switch the indoor fan speed. It has already been
set by the Auto Operation Mode rule.
To raise the temperature
* Please select the code
depend on your feeling.
To lower the temperature
Code
Feel
2
Cold
1
Slightly cool
0
Neutral
-1
Slightly warm
-2
Warm
<For Heating Model>
You can set desired temperature and
indoor fan speed.
Setting Temp. Range :
18~30 °C(64~86 °F)
!
NOTE
During Auto Operation Mode
- If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating to cooling, then
you must set the mode and the desired temperature again.
OWNER'S INSTRUCTION 17
ENGLISH
Auto Changeover Mode
1
Press the ON/OFF button. The unit will respond with beep sound.
2
Press MODE button to select Auto
Changeover Mode.
3
Set the desired room temperature.
* Setting Temp. Range in Auto
Changeover Mode : 18~30 °C
(64~86 °F)
4
!
To raise the temperature
To lower the temperature
You can select the fan speed in four stepsslow, medium, high and chaos. Each time the
button is pressed, the fan speed mode is
shifted.
NOTE
During Auto changeover Mode
The air conditioner changes the operation mode automatically to keep indoor temperature.
When room temperature vary over ±2 °C(4 °F) with respect to setting temperature, air conditioner keeps the room temperature within ±2 °C(4 °F) with respect to setting temperature by
auto changeover mode.
18 OWNER'S INSTRUCTION
ENGLISH
Auto Changeover Mode - Setting the Mode Change Temperature
This Function is to set the operating mode of the Auto Changeover Mode.
1
In Auto Changeover Mode, Press FUNCTION button to select
Setting the Mode Change Temperature.
2
Press the TEMPERATURE SETTING button to set desired Mode Change Temperature.
(Default value is 2 °C(4 °F).)
To raise the temperature
To lower the temperature
!
* Mode Change Temp. Range :
1~7 °C(2~14 °F)
NOTE
The Mode Change Temperature is the difference of temperature when from cooling mode
to heating mode or from heating mode to cooling mode.
Ex) When setting temperature is 25 °C(76 °F) and room temperature is 20 °C(68 °F), then
operating mode is heating. If you set the mode change temperature to 2 °C(4 °F), when
the room temperature up to 27 °C(25 °C + 2 °C)(80 °F(76 °F + 4 °F)), the unit start cooling operation.
OWNER'S INSTRUCTION 19
Up/Down Airflow Direction Control (Optional)
The up/down airflow (Vertical Airflow) can be adjusted by using the remote controller.
1 Press the ON/OFF button to start the unit.
2 Press up/down airflow button and the louvers will swing up and down.
Press the up/down airflow button again to set the vertical louver at the desired airflow direction.
!
NOTE
• If you press the UP/DOWN AIRFLOW button, the horizontal airflow direction is changed automatically based on the Auto Swing algorithm to distribute the air in the room evenly and
at the same time to make the human body feel more comfortable, as if enjoying a natural
breeze.
• Always use the remote controller to adjust the up/down airflow direction. Manually moving
the vertical airflow direction louver by hand, could damage the air conditioner.
• When the unit is shut off, the up/down airflow direction louver will close the air outlet vent
of the system.
Celsius/Fahrenheit Switching
- Press the °C/°F SWITCH button to change from Celsius to Fahrenheit or from Fahrenheit to
Celsius.
- Whenever press TEMPERATURE SETTING button in Fahrenheit mode, the temperature
will increase/drop 2 °F.
ENGLISH
Airflow Setting
20 OWNER'S INSTRUCTION
ENGLISH
Temperature Setting/Room Temperature checking
We can simply adjust the desired temperature
- Press the buttons to adjust the desired temperature
: Increase Temp. per one time pressing
: Decrease Temp. per one time pressing
Room temp: Indicate the current room temperature
Set temp: Indicate the temperature that user want to set
<Cooling Mode>
The cooling mode doesn't work if desired temperature is higher
than room temperature Please lower the desired temperature
<Heating Mode>
The heating mode doesn't work if desired temperature is lower
than room temperature Please increase the desired temperature
Whenever press ROOM TEMPERATURE button, the room temperature will be displayed within 5 seconds.
After 5 seconds, it turns to display the desired temperature.
Because of location of remote controller, the real room temperature
and the this displayed value can be different.
Press ROOM TEMPERATURE button for 5 seconds, temperature
unit change Celsius to Fahrenheit or Fahrenheit to Celsius.
SUB FUNCTION 21
ENGLISH
SUB FUNCTION
Plasma Purification(Optional)
PLASMA Purification only
1
Press the ON/OFF button.
The unit will respond with beep sound.
2
Press the PLASMA button. Plasma Purification will start when the button is pressed
and stop when the button is pressed again.
If you press the PLASMA button, Plasma Purification operates.
• Plasma filter is a technology developed by LG to
get rid of microscopic contaminants in the intake
air generating a plasma of high charge electrons.
This plasma kills and destroys the contaminants
completely to provide clean and hygienic air.
• This function can be used in any operation mode
and any fan speed can be used while plasma filter
is functioning.
Auto Clean (Optional)
This function operate when the unit is turned off.
1
Press the FUNCTION SETTING button 1 time.
Auto Clean symbol will blink.
2
Press the SET/CLEAR button to reserve or cancel the Auto Clean function.
If the Auto Clean function is reserved, whenever the unit is turned off,
the indoor fan is still running for about 30 minutes internally without
cooling or dehumidification operation. Also the louver is closed.
This dries up any remains of moisture & cleans the unit internally.
22 SUB FUNCTION
ENGLISH
Smart Clean (Optional)
The Smart Clean function can be used by setting to manual or automatic.
Auto Smart Clean operation
If the accumulated operation time of the product exceeds 30 hours, the Smart Clean automatically starts when the unit is turned off.
1 Press the FUNCTION SETTING button 2 times.
Smart Clean symbol will blink.
2 Press the SET/CLEAR button to reserve or cancel
the Smart Clean function.
You can set/clear with out on or off.
Manual Smart Clean operation
1 When the unit stop, press the FUNCTION button to select
Smart Clean.
Smart Clean symbol blinks, then press SET/CLEAR button.
2 To stop Manual Smart Clean operation, press the FUNCTION
button to select Smart clean and press SET/CLEAR button.
The brush clean a dust from the filter by moving from left to right or from right to left on the
filter. The sucked dust is collected into the dust box.
The operating process of Smart Clean is different from the product type.
SUB FUNCTION 23
Press the LCD LUMINOSITY button.
It is comfortable when you feel that the display of the unit too bright .
Celsius/Fahrenheit Switching
Press the °C/°F SWITCH button to change from Celsius to Fahrenheit or
from Fahrenheit to Celsius.
Whenever press TEMPERATURE SETTING button in Fahrenheit mode, the
temperature will increase/drop 2 °F.
Electric heater (Optional)
It can only be set during heating operation.
1
Press the FUNCTION SETTING button 3 times.
Electric heater symbol will blink.
2
Press the SET/CLEAR button to reserve or cancel the Electric heater
function.
• The indoor unit displays during the heating mode, the Auxiliary heater is automatically
turned on, but it is not displayed on the wireless remote controller separately.
• It operates in Floor heating mode in Console products.
ENGLISH
LCD Luminosity Control (Optional)
24 SUB FUNCTION
ENGLISH
Individual vane angle control (Optional)
It is the function that can control 4 vane angles individually in the ceiling type 4Way cassette
product group.
1
Press the FUNCTION SETTING button 3 times.
(4 times during heating operation)
Individual vane angle control symbol will blink.
• If you press the SET/CLEAR button in that
time, all vanes are set to standard angle.
2
Set each vane angle by pressing up/down/left/right direction
keys.
• Every time the button is pressed, corresponding vane
angle and set values are displayed.
• When up direction button is pressed, the display window
appears as of the figure in the right, and the angle can be
set to 1~6.
3
Press SET/CLEAR button to reserve or cancel the individual vane angle control function.
• There may be differences between wireless remote controller up/down/left/right buttons
and the wind discharge port directions.
• Set desired angle with checking the vane angle movement of the product.
• The individual vane control function is an additional function of a product, and it may not
work in some products.
TIMER 25
ENGLISH
TIMER
Setting the Current Time
1 Press the SET / CLEAN button for 3 seconds.
2 Press TIME SETTING buttons until the desired time is set.
(If you press down the button for a long time, it will change
quickly in the units of 10 min.)
3 Press the SET / CLEAR button.
!
NOTE
Check the indicator for A.M. and P.M.
Sleep Timer Setting
1 Press the TIMER button to turn timer on or off.
Timer Sleep
2 Press TIME SETTING buttons until the desired time is set.
(7 hours is the maximum setting)
3 Press the SET / CLEAR button.
On Timer Setting
1 Press the ON button to turn timer on or off.
Timer ON
2 Press TIME SETTING buttons until the desired time is set.
3 Press the SET / CLEAR button.
26 TIMER
ENGLISH
Off Timer Setting
1 Press the OFF button to turn timer on or off.
Timer OFF
2 Press TIME SETTING buttons until the desired time is set.
3 Press the SET / CLEAR button.
To cancel the Timer Setting
- If you wish to cancel all timer setting, press the CLEAR ALL button.
- If you wish to cancel each timer setting, press the
each timer button to turn timer sleep or on or off as you want.
And then press the SET/CLEAR button aiming the remote
controller at the signal receptor.
(The timer lamp on the air conditioner and the display will go off.)
MAINTENANCE AND SERVICE 27
Indoor Unit
- Remove the Air filters.
Grille, Case and Remote Control
- Turn the system off before cleanining, To
clean, wipe with a soft, dry cloth. Do not use
bleach or abrasives.
!
NOTE
Take hold of the tab and pull slightly forward
to remove the filter.
! CAUTION
When the air filter is to be removed, do
not touch the metal parts of the indoor
unit.
It may cause an injury.
Supply power must be disconnected before cleaning the indoor unit.
- Clean dirt from the air filter using a vacuum
Air Filters
The air filters behind the front grille should be
checked and cleaned once every 2 weeks or
more often if neccessary.
cleaner or washing with water.
If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
If hot water (40 °C or more) is used, it may
be deformed.
- After washing with water, dry well in the
shade.
Do not expose the air filter to direct sunlight
or heat from a fire when drying it.
- Install the air filter.
- Never use any of the followings:
Water hotter than 40 °C.
Could cause deformation and or discoloration.
Volatile substances.
Could damage the surfaces of the air conditioner.
SI
B en
z ene
N N ER
S CO
U RI N
CLB
ARGE
ENGLISH
MAINTENANCE AND SERVICE
28 MAINTENANCE AND SERVICE
ENGLISH
Purifying filter(Optional)
Cleaning
- The PLASMA filter behind the air filters
should be checked and cleaned once every 3
months or more often if necessary.
Replacement
Recomended use period : About 2 years
- After removing the air filters, pull
slightly forward to remove the PLASMA
filter.
- Dip the PLASMA filter into the water
mixed with neutral detergent, for 20~30
minutes.
- Dry the PLASMA filter in the shade for
a day (Especially, the humidity must be
removed perfectly on this parts).
- Note the cuts of electric discharge
lines.
- Remove air purifying filter.
- Open front panel and remove air filter.
- Insert new air purifying filter.
1
2
- Re-install the PLASMA filter to the original position.
- Reinsert air filter and close front panel.
! CAUTION
Don’t touch this PLASMA Filter within 10
seconds after opening the inlet grille, it
may cause an electric shock.
MAINTENANCE AND SERVICE 29
Do not overcool the room.
This is not good for the health
and wastes electricity.
Keep blinds or curtains closed.
Do not let direct sunshine
enter the room when the air
conditioner is in operation.
Keep the room temperature
uniform.
Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in
the room.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and windows as much as possible to
keep the cool air in the room.
Clean the air filter regularly.
Blockages in the air filter reduce the airflow and lower
cooling and dehumidifying effects. Clean at least once
every two weeks.
Ventilate the room occasionally.
Since windows are kept
closed, it is a good idea to
open them and ventilate the
room now and then.
When the air conditioner is not
going....
When air conditioner is not going to
be used for a long time.
- Operate the air conditioner at the following
settings for 2 to 3 hours.
Type of operation: Fan operation mode.
(Refer to page “Fan Mode”.)
This will dry out the internal mechanisms.
- Turn off the breaker.
! CAUTION
Turn off the breaker when the air conditioner is not going to be used for a long
time.
Dirt may collect and may cause a fire.
- Remove the batteries from the Remote Controller.
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will
be wasted.
When the air conditioner is to be
used again.
- Clean the air filter and install it in the indoor
unit. (Refer to page “MAINTENANCE AND
SERVICE”.)
- Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
- Check that the ground wire is connected correctly. It may be connect to the indoor unit
side.
ENGLISH
Operation Tips!
30 MAINTENANCE AND SERVICE
ENGLISH
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist,
please contact your dealer.
The air conditioner
does not operate.
- Have you made a
mistake in timer operation?
- Has the fuse blown
or has the circuit
breaker been
tripped?
The room has a peculiar odor.
- Check that this is not
a damp smell exuded by the walls,
carpet, furniture or
cloth items in the
room.
It seems that condensation is leaking from
the air conditioner.
- Condensation occurs
when the airflow
from the air conditioner cools the
warm room air.
Air conditioner does
not operate for about
3 minutes when
restart.
- This is the protector
of the mechanism.
- Wait about three
minutes and operation will begin.
Does not cool or heat
effectively.
- Is the air filter dirty?
See air filter cleaning
instructions.
- The room may have
been very hot when
the room air conditioner was first
turned on. Allow
time for it to cool
down.
- Has the temperature
been set incorrectly?
- Are the indoor unit's
air inlet or outlet
vents obstructed?
The air conditioner operation is noisy.
- For a noise that
sounds like water
flowing.
* This is the sound
of freon flowing inside the air conditioner unit.
- For a noise that
sounds like the compressed air releasing
into atmosphere.
- This is the sound of
the dehumidifying
water being
processed inside the
air conditioning unit.
Crack sound is heard.
- This sound is generated by the expansion/ constriction of
the front panel, etc.
due to changes of
temperature.
Remote control display is faint, or no display at all.
- Are the batteries depleted?
- Are the batteries inserted in the opposite (+) and (-)
directions?
Filter sign lamp (LED)
is ON.
- Cleaning the filter,
press the Timer button and ◀ button of
wired remote controller at the same
time for 3 sec.
The error code is occurred after lightning
struck
- This product has been
applied to the over
current protection circuit.
Error can occur, but it
is normal behavior.
After few minutes, It
will operate normally.
Call the service immediately in the following situations
- Anything abnormal such as burning smell, loud noise etc. happen. Stop the unit and turn the
breaker off. Never try to repair by yourself or restart the system in such cases.
- Main power cable is too hot or damaged.
- Error code is generated by self diagnosis.
- Water leaks from indoor unit even if the humidity is low.
- Any switch, breaker (safety, earth) or fuse fails to work properly
User must carry routine checkup & cleaning to avoid unit’s poor performance.
In case of special situation, the job must be carried out by service person only.