LG | LMNC182TEC0 | LG LMNC182TEC0 Owner’s Manual

website http://www.lgservice.com
LG
LG
Room Air Conditioner
OWNER'S MANUAL
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
P/No.: 3828A20478J
Ceiling Mounted Cassette - 4Way Type Indoor Unit Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety Precautions.................3
Write the model and serial numbers here:
Model #
Serial #
Prior to Operation ..................8
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Operating Instructions...........9
■ Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
Maintenance and Service ....25
READ THIS MANUAL
Before you Call
for Service .........................27
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
• Contact the authorized service technician for repair or
maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by young
children or invalids without supervision.
• Young children should be supervised to ensure that
they do not play with the air conditioner.
• When the power cord is to be replaced, replacement
work shall be performed by authorized personnel only
using only genuine replacement parts.
• Installation work must be performed in accordance with
the National Electric Code by qualified and authorized
personnel only.
2 Multi Type Air Conditioner
Safety Precautions
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be
followed.
■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified
by the following indications.
WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to properties only.
■ Meanings of symbols used in this manual are as shown below.
Be sure not to do.
Be sure to follow the instruction.
■ Installation
Do not use a defective or
underrated circuit breaker.
Use this appliance on a
dedicated circuit.
WARNING
For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.
• There is risk of fire or electric
shock.
• Do not disassemble or repair
the product. There is risk of fire
or electric shock.
Install the panel and the
cover of control box
securely.
Always install a dedicated
circuit and breaker.
• There is risk of fire or electric
shock.
• Improper wiring or installation
may cause fire or electric shock
Always ground the product.
• There is risk of fire or electric
shock.
Use the correctly rated
breaker or fuse.
• There is risk of fire or electric
shock.
Owner’s Manual 3
Safety Precautions
Do not modify or extend the
power cable.
• There is risk of fire or electric
shock.
Do not install, remove, or
re-install the unit by
yourself (customer).
• There is risk of fire, electric
shock, explosion, or injury.
For installation, always contact the
dealer or an Authorized Service Center.
• There is risk of fire, electric
shock, explosion, or injury.
Do not install the product on
a defective installation stand.
• It may cause injury, accident, or
damage to the product.
Be cautious when
unpacking and installing
the product.
• Sharp edges could cause injury.
Be especially careful of the
case edges and the fins on the
condenser and evaporator.
Be sure the installation area
does not deteriorate with age.
• If the base collapses, the air
conditioner could fall with it,
causing property damage,
product failure, and personal
injury.
■ Operation
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
• Moisture may condense and
wet or damage furniture.
Take care to ensure that power
cable could not be pulled out
or damaged during operation.
• There is risk of fire or electric
shock.
• There is risk of fire or electric
shock.
Do not touch(operate) the
product with wet hands.
Do not place a heater or
other appliances near the
power cable.
• There is risk of fire or electrical
shock.
• There is risk of fire and electric
shock.
Do not plug or unplug the
power supply plug during
operation.
• There is risk of fire or electric
shock.
Do not place anything on
the power cable.
4 Multi Type Air Conditioner
Safety Precautions
Do not allow water to run
into electric parts.
Do not store or use flammable
gas or combustibles near the
product.
Do not use the product in a
tightly closed space for a
long time.
• It may cause There is risk of
fire, failure of the product, or
electric shock.
• There is risk of fire or failure of
product.
• Oxygen deficiency could occur.
Gasolin
When flammable gas leaks,
turn off the gas and open a
window for ventilation
before turn the product on.
If strange sounds, or small or
smoke comes from product. Turn
the breaker off or disconnect the
power supply cable.
• Do not use the telephone or
turn switches on or off.
There is risk of explosion or fire
• There is risk of electric shock or
fire.
Do not open the inlet grill of the
product during operation.
(Do not touch the electrostatic
filter, if the unit is so equipped.)
• There is risk of physical injury,
electric shock, or product
failure.
When the product is soaked
(flooded or submerged),
contact an Authorized
Service Center.
• There is risk of fire or electric
shock.
Ventilate the product from time to time
when operating it together with a stove, etc.
• There is risk of fire or electric shock.
Stop operation and close the window
in storm or hurricane. If possible,
remove the product from the window
before the hurricane arrives.
• There is risk of property
damage, failure of product, or
electric shock.
Be cautious that water
could not enter the product.
• There is risk of fire, electric
shock, or product damage.
Turn the main power off when cleaning or
maintaining the product.
• There is risk of electric shock.
Owner’s Manual 5
Safety Precautions
When the product is not be used for a long
time, disconnect the power supply plug or
turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody could step
on or fall onto the outdoor unit.
• This could result in personal injury and product
damage.
CAUTION
■ Installation
Always check for gas
(refrigerant) leakage after
installation or repair of product.
• Low refrigerant levels may
cause failure of product.
Install the drain hose to ensure
that water is drained away
properly.
• A bad connection may cause
water leakage.
Keep level even when
installing the product.
• To avoid vibration or water
leakage.
90˚
Do not install the product where the
noise or hot air from the outdoor unit
could damage the neighborhoods.
• It may cause a problem for your
neighbors.
Use two or more people to lift
and transport the product.
• Avoid personal injury.
Do not install the product
where it will be exposed to
sea wind (salt spray) directly.
• It may cause corrosion on the product.
Corrosion, particularly on the condenser
and evaporator fins, could cause product
malfunction or inefficient operation.
■ Operation
Do not expose the skin directly to cool air
for long periods of time.
(Don't sit in the draft.)
• This could harm
to your health.
6 Multi Type Air Conditioner
Do not use the product for special purposes, such as
preserving foods, works of art, etc. It is a consumer
air conditioner, not a precision refrigeration system.
• There is risk of
damage or
loss of property.
Safety Precautions
Do not block the inlet or
outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do
not use harsh detergents,
solvents, etc.
• There is risk of fire, electric
shock, or damage to the plastic
parts of the product.
Do not touch the metal parts of
the product when removing the
air filter. They are very sharp!
• There is risk of personal injury.
x
Wa Thinner
Do not step on or put
anyting on the product.
(outdoor units)
• There is risk of personal injury
and failure of product.
Do not drink the water
drained from the product.
• It is not sanitary and could
cause serious health issues.
Always insert the filter
securely. Clean the filter
every two weeks or more
often if necessary.
• A dirty filter reduces the efficiency
of the air conditioner and could
cause product malfunction or
damage.
• There are sharp and moving
parts that could cause personal
injury.
Use a firm stool or ladder
when cleaning or
maintaining the product.
Replace the all batteries in the
remote control with new ones
of the same type. Do not mix
old and new batteries or
different types of batteries.
• Be careful and avoid personal
injury.
• There is risk of fire or explosion
Do not recharge or disassemble the
batteries. Do not dispose of batteries in a
fire.
• They may burn or explode.
Do not insert hands or other
objects through the air inlet
or outlet while the product
is operated.
If the liquid from the batteries gets onto your skin
or clothes, wash it well with clean water. Do not
use the remote if the batteries have leaked.
• The chemicals in batteries could cause burns or
other health hazards.
Owner’s Manual 7
Prior to operation
Prior to Operation
Preparing for operation
1. Contact an installation specialist for installation.
2. Use a dedicated circuit.
Usage
1. Being exposed to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or
other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g. preserving precision
devices, food, pets, plants, and art objects). Such usage could damage the items.
Cleaning and maintenance
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and breaker are turned off. The fan rotates
at a very high speed during operation. There is a possibility of injury if the unit’s power is
accidentally triggered on while cleaning inner parts of the unit.
Service
For repair and maintenance, contact your authorized service dealer.
8 Multi Type Air Conditioner
Operating Instructions
Remote Controller
AUTO SWING
OPERATION
SET TEMP
Room Temp
Timer
Operation unit
03
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
6
3
17
10
11
12
13
14
15
Heat Pump Model
1
2
Timer
Cancel
Program
Week
5
Holiday
Plasma
Set/Clr
Hour
Min
RESET
16
18
Cooling Model
4
7
8
9
1. Operation display
Displays the operation conditions.
9. Plasma Air Clean Button (optional)
2. On/Off Button
Operation starts when this button is pressed, and stops
when the button is pressed again.
10. Timer Cancel Button
Used to cancel the timer.
3. Set Temperature Button
Used to set the temperature when the desired
temperature is obtained.
4. FAN Operation Button
Used to circulate room air without cooling or heating.
5. Fan Speed Button
Used to set the desired fan speed.
6. Operation Mode Selection Button
Used to select the operation mode.
• Auto Operation Mode
• Cooling Operation Mode
• Soft Dry Operation Mode
• Heating Operation Mode(except cooling model)
11. Timer Set Button
Used to set the timer when the desired time is obtained.
12. Week Button
Used to set a day of the week.
13. Program Button
Used to set the weekly timer.
14. Holiday Button
Used to set a holiday of the week.
15. Time Set Button
Used to set the time of the day and change the time in
the weekly timer Function.
16. Set and Clear Button
Used to set and clear the weekly timer.
7. Auto Swing Button
Used to swing up and down.
17. Swirl Button
Used to select swirl mode.
8. Room Temperature Checking Button
Used to check the room temperature.
18. Reset Button
Used to set the current time and clear the setting time.
❈ Display temperature can be different from actual room temperature if the remote controller is
installed at the place where sun-rays are falling directly or the place nearby heat source.
Owner’s Manual 9
Operating Instructions
Wireless Remote Controller (optional)
This air-conditioner is equipped with wired remote controller basically. But if you want to be available with
wireless remote controller, you pay for it.
1. OPERATION DISPLAY
Signal transmitter
Displays the operation conditions.
(Transmits the signals to the signal receptor) 2. ON/OFF BUTTON
Operation starts when this button is pressed and stops
when the button is pressed again.
3. JET COOL BUTTON
Used to select jet cool mode.
4. ON/OFF TIMER BUTTONS
1
Used to set the time of starting and stopping operation.
5. TIME SETTING BUTTONS
Used to adjust the time.
6. TIMER SET/CANCEL BUTTONS
Used to set the timer when the desired time is obtained
7
3
and to cancel the Timer operation.
7. AIR SWING BUTTON
12
2
Used to swing up and down.
13
8. SLEEP MODE BUTTON
ON
OFF
Used to set Sleep Mode Auto operation.
8
4
9. AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or heating
9
5
SET
CANCEL
(turns indoor fan on/off).
6
10
PLASMA
ROOM TEMPERATURE CHECKING BUTTON
10.
Heat Pump 14
15
Used to check the room temperature.
Model
11
11. RESET BUTTON
Used prior to resetting time or after replacing batteries.
12. INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps-low, medium, high,
Cooling Model
or CHAOS.
Flip-up door 13. ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
(opened)
14. ORERATION MODE SELECTION BUTTON
Used to select the operation mode.
15. PLASMA AIR CLEAN BUTTON(OPTIONAL)
CAUTION
of handling the Remote Controller
• Aim at the signal receptor on the wired remote controller so as to operate.
• The remote control signal can be received at a distance of up to about 7m.
• Be sure that there are no obstructions between the remote controller and the signal receptor.
• Do not drop or throw the remote controller.
• Do not place the remote controller in a location exposed to direct sunlight, or near the heating unit, or any
other heat source.
• Block a strong light over the signal receptor with a curtain or etc. so as to prevent the abnormal operation.
(ex:electronic quick start, ELBA, inverter type fluorescent lamp)
10 Multi Type Air Conditioner
Operating Instructions
Set the Current Time and day of the Week
Unless you press any button about 5 (sometimes 10) seconds while setting function, the setting mode returns to
initial mode.
1
Press the '
' button.
Hour
Each time the button is pressed, the number is changed from 00 to 23.
This number indicates current hour.
AUTO SWING OPERATION SET TEMP
Room Temp
Hour
Operation unit
For example, if it is 14:25, press
2
Press the '
Hour
03
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
07
09
11
13
15
17
19
21
23
button 14 times.
' button.
Min
Each time the button is pressed, the number increases from 00 to 59.
This number indicates current minute.
AUTO SWING OPERATION SET TEMP
Room Temp
Timer
Operation unit
On Off
Set no. Time 01
Press '
03
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Min
3
SUB FUNCTION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Week
' button.
Each time the button is pressed, a day of the week is shifted from sunday to saturday.
AUTO SWING
Week
OPERATION
SET TEMP
Room Temp
Operation unit
4
Press the '
RESET
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
' button.
If you want to confirm the current time and a day of the week, click the Reset button.
RESET
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Owner’s Manual 11
Operating Instructions
Weekly Programming
1
Press the Program button.
The remote controller is displayed like a picture. Then '
Program
', '
Program set
AUTO SWING
OPERATION
' and '01' is blinked.
SET TEMP
Room Temp
2
Week
Press the '
Press
Week
03
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
07
09
' button.
button repeatedly until desired mode appears.
Week
3
Select the time you want.
Press
Hour
or
If you press
button, then blinking letter is shown.
Min
SET/CLR
button, then '
' shape appears.
unit
'
05
' shape means that five o'clock is reserved.
Using below buttons, you can reserve time.
SET/CLR
Hour
Min
* For example, the air-conditioner is on 6,7,8 and 13~22 o'clock.
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
12 Multi Type Air Conditioner
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
SUB FUNCTION
HI
MED
LO
Time
Operation unit
Timer
On Off
Set no. Time 01
FAN SPEED
21
23
11
13
15
17
19
21
23
Operating Instructions
Holiday Setting
If Tuesday is a holiday in this week, you may set a holiday.
AUTO SWING
OPERATION
SET TEMP
Room Temp
Press the Program button.
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
Week
2
Operation unit
Program set
On Off
Set no. Time 01
03
AUTO SWING
OPERATION
05
07
09
11
13
SET TEMP
Press the Week button.
Select the Tuesday.
Room Temp
3
Press the Holiday button.
Holiday
Operation unit
03
AUTO SWING
OPERATION
Timer
05
07
Operation unit
On Off
Set no. Time 01
03
19
FAN SPEED
21
23
SUB FUNCTION
Program set
On Off
Set no. Time 01
09
11
13
SET TEMP
15
17
19
FAN SPEED
21
23
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
'.
17
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Room Temp
Then the remote controller will be displayed '
The outside rectangular means holiday.
15
HI
MED
LO
Time
Timer
SUB FUNCTION
HI
MED
LO
Program
1
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Timer Setting
If you want to turn it 'ON' during 'OFF' mode or turn it 'OFF' during 'ON' mode, you can use timer
setting function.
Timer
1
Press the Timer button.
2
Press
Hour
or
Min
If you press
button, then you can control the desired time.
Hour
button, the display panel shows ( ex :
O eration un
01
03
Min
).
Min
It means 3 hours later, it will stop while 'ON' mode, it will operate while 'OFF' mode.
3
If you want to cancel the timer setting function, press the Cancel button.
Cancel
Self-diagnosis Function
' CH' will flash in the remote controller display when a problem occurs.
Then please contact your dealer.
Owner’s Manual 13
Operating Instructions
Operation Mode
Cooling Mode
Cooling Mode
Soft Dry Mode
Soft Dry Mode
Heating Mode
Auto Mode
(Cooling Model)
Auto Mode
(Heat Pump Model)
Operation Procedure
1st
On/Off Button
AUTO SWING
OPERATION
SET TEMP
Room Temp
2nd
Operation Mode Selection Button
Operation unit
03
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
3
1
3rd
Room Temperature Setting Button
Timer
Cancel
Program
Week
Holiday
Plasma
SET/CLR
Hour
4th
Indoor Fan Speed Selection Button
14 Multi Type Air Conditioner
Min
RESET
2
4
Operating Instructions
Cooling Operation Mode
1 Press the On/Off Button.
Cooling Operation.
2 Select
Press the Operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
HEAT PUMP MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
03
Timer
Program set
05
07
09
11
OPERATION
SET TEMP
13
15
17
Cooling Operation
03
SUB FUNCTION
AUTO SWING
07
09
Timer
11
SET TEMP
13
15
17
Soft Dry Operation
03
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
15
17
On Off
21Set no.
23 Time 01
19
Heating Operation
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
AUTO SWING
SUB FUNCTION
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
COOLING MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
03
AUTO SWING
07
09
11
SET TEMP
15
17
19
21
On Off
Set no. Time 01
23
Cooling Operation
03
SUB FUNCTION
07
09
11
15
17
19
21
OPERATION
SET TEMP
Operation unit
03
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
• The temperature can be set within
a range of 18°C-30°C by 1°C
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
Operation unit
On Off
Set no. Time 01
23
Soft Dry Operation
FAN SPEED
Room Temp
FAN SPEED
Time
Timer
13
SET TEMP
Room Temp
Program set
05
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
3 Set the temperature lower than the room temperature.
AUTO SWING
AUTO SWING
HI
MED
LO
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
Program set
05
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
SUB FUNCTION
HI
MED
LO
To raise the Temperature.
Program set
05
07
09
11
13
15
17
19
21
23
To lower the Temperature.
4 Set the fan speed.
Operation Display
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
07
09
11
OPERATION
Timer
13
15
17
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
AUTO SWING
SUB FUNCTION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
03
07
09
11
OPERATION
Timer
13
15
17
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
SUB FUNCTION
AUTO SWING
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
FAN SPEED
03
07
09
11
OPERATION
Timer
13
15
17
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
SUB FUNCTION
AUTO SWING
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
FAN SPEED
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
On Off
21Set no.
23 Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
• Select the fan speed in four steps-high, Auto, low, medium.
• The display shows high fan speed.
• Each time the button is pressed, the fan speed mode is shifted.
Owner’s Manual 15
Operating Instructions
Soft Dry Operation Mode
This mode dehumidifies without overcooling.
1 Press the On/Off Button.
2 Select Soft Dry Operation.
Press the operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
HEAT PUMP MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
AUTO SWING
SUB FUNCTION
07
09
11
SET TEMP
Timer
13
15
17
03
SUB FUNCTION
AUTO SWING
07
09
11
Timer
13
15
17
Soft Dry Operation
Cooling Operation
03
FAN SPEED
SUB FUNCTION
AUTO SWING
07
09
11
SET TEMP
15
17
19
On Off
21Set no.
23 Time 01
Heating Operation
03
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
07
09
11
13
15
17
19
Auto Operation
COOLING MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
SUB FUNCTION
Program set
05
07
09
11
AUTO SWING
OPERATION
15
17
19
Cooling Operation
21
23
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
Program set
05
07
09
11
AUTO SWING
OPERATION
15
17
19
21
Soft Dry Operation
23
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
3 During Dry Operation.
• The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is
impossible because of already being set to the best speed for Dry Operation by Micom
Control.
16 Multi Type Air Conditioner
SUB FUNCTION
HI
MED
LO
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
21
23
Operating Instructions
Heating Operation Mode (Heat pump model only)
1 Press the On/Off Button.
2 Select Heating Operation.
Press the Operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
Operation Display
AUTO SWING
OPERATION
SET TEMP
Operation unit
03
07
09
11
SET TEMP
15
17
On Off
21 Set no.
23 Time 01
19
Cooling Operation
03
SUB FUNCTION
AUTO SWING
07
09
11
Timer
13
15
17
Soft Dry Operation
03
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
Timer
On Off
Set no. Time 01
03
07
09
SET TEMP
13
15
17
Heating Operation
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
On Off
21Set no.
23 Time 01
19
FAN SPEED
Room Temp
Timer
11
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
• The temperature can be set within a
range of 16°C-30°C by 1°C
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
SUB FUNCTION
AUTO SWING
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
19
FAN SPEED
Room Temp
3 Set the temperature higher than the room temperature.
AUTO SWING
SET TEMP
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
Timer
13
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
AUTO SWING
SUB FUNCTION
FAN SPEED
Room Temp
To raise the Temperature.
Program set
05
07
09
11
13
15
17
19
21
23
To lower the Temperature.
4 Set the fan speed.
Operation Display
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
07
09
11
OPERATION
Timer
13
15
17
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
AUTO SWING
SUB FUNCTION
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
03
07
09
11
OPERATION
SET TEMP
Timer
13
15
17
19
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
SUB FUNCTION
AUTO SWING
HI
MED
LO
Time
Operation unit
On Off
21 Set no.
23 Time 01
FAN SPEED
03
Program set
05
07
09
11
OPERATION
15
17
19
FAN SPEED
On Off
21Set no.
23 Time 01
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
On Off
21Set no.
23 Time 01
SUB FUNCTION
AUTO SWING
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
• Select the fan speed in four steps-high, Auto, low, medium.
• The display shows high fan speed
• Each time the button is pressed, the fan speed mode is shifted.
air-conditioner is set to the hot start control in order not
5 This
to discharge the cold air during the heating operation. This
AUTO SWING
OPERATION
Room Temp
time, the remote controller indicates ‘Preheat’.
Operation unit
03
AUTO SWING
OPERATION
05
07
09
11
13
SET TEMP
Room Temp
operation and the remote controller indicates ‘Defrost’.
Operation unit
03
15
17
19
FAN SPEED
21
23
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
On Off
Set no. Time 01
On Off
Set no. Time 01
FAN SPEED
HI
MED
LO
Time
Timer
the outdoor temperature is too low during the heating
6 Ifoperation,
this air-conditioner is set to the defrosting
SET TEMP
Program set
05
07
09
11
13
15
17
19
21
23
Owner’s Manual 17
23
Operating Instructions
Auto Operation Mode (Cooling model)
1 Press the On/Off Button.
Auto Operation, press the Operation Mode Selection button.
2 ToEachselect
time the button is pressed, the operation mode is shifted in the direction of the arrow.
COOLING MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
Operation unit
03
AUTO SWING
07
09
11
15
17
19
21
FAN SPEED
Operation unit
On Off
Set no. Time 01
23
03
SUB FUNCTION
AUTO SWING
07
09
11
15
17
19
21
Operation unit
On Off
Set no. Time 01
23
Soft Dry Operation
03
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Timer
13
Cooling Operation
3
SET TEMP
Room Temp
Program set
05
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
SUB FUNCTION
HI
MED
LO
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
The temperature and fan speed are automatically set by the electronic controls based on the actual
room temperature. If you want to change the set temperature, close the door on the remote control
and press the Room Temperature Setting buttons. The cooler or warmer you feel, the more times
(up to two times) you should press the button. The set temperature will then be changed.
The temperature can be set within a range of -2~2 by 1 level.
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
On Off
Set no. Time 01
03
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
(This indication will be shifted to the initial
Auto Mode Display state after 5 seconds.)
Cold Cool
Proper
Warm
Hot
To raise the Temperature.
To lower the Temperature.
During Auto Operation:
❏ You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule.
❏ If the system is not operating as desired, manually switch to another mode. The system will not
automatically switch from the cooling mode to the heating mode, or from heating to cooling, it must be
done by manually resetting.
❏ During Auto Operation, pressing the chaos swing button makes the horizontal louvers swing up and
down automatically. If you want to stop auto-swing, press the chaos swing button again.
18 Multi Type Air Conditioner
Operating Instructions
Auto Operation Mode (Heat pump model)
1 Press the On/Off Button.
Auto Operation, press the Operation Mode Selection button.
2 ToEachselect
time the button is pressed, the operation mode is shifted in the direction of the arrow.
HEAT PUMP MODEL
Operation Display
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
AUTO SWING
SUB FUNCTION
Timer
Program set
05
07
09
11
13
15
17
19
Cooling Operation
setting temperature
3 The
can be changed, when
the set temperature
button is pressed.
OPERATION
SET TEMP
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Timer
On Off
Set no. Time 01
FAN SPEED
03
Program set
05
07
09
11
Timer
13
15
OPERATION
SET TEMP
Room Temp
19
Operation unit
On Off
Set no. Time 01
03
SET TEMP
Room Temp
03
FAN SPEED
Program set
05
07
09
11
Timer
13
15
17
Heating Operation
FAN SPEED
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
SUB FUNCTION
AUTO SWING
OPERATION
19
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
HI
MED
LO
Time
Timer
17
Soft Dry Operation
AUTO SWING
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
On Off
21 Set no.
23 Time 01
SUB FUNCTION
AUTO SWING
HI
MED
LO
03
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Operation unit
On Off
21Set no.
23 Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Auto Operation
• The temperature can be set
within a range of 18°C-30°C
by 1°C
Program set
05
07
09
11
13
15
17
19
21
23
To raise the Temperature.
To lower the Temperature.
During Auto Operation:
❏ You can switch the indoor fan speed.
❏ The system will automatically switch from the cooling mode to the heating mode, or from heating to
cooling, when you select Auto Opration mode.
Owner’s Manual 19
Operating Instructions
FAN Operation Mode
1 Press the On/Off Button.
2 Press FAN Operation Button.
AUTO SWING
OPERATION
SET TEMP
Room Temp
03
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
HI
MED
LO
Time
Operation unit
Timer
On Off
Set no. Time 01
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
time Fan Speed button is pressed, the fan speed mode is shifted in the arrow
3 Each
direction.
AUTO SWING
OPERATION
SET TEMP
Room Temp
On Off
Set no. Time 01
AUTO SWING
OPERATION
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Operation unit
On Off
Set no. Time 01
03
Program set
05
07
09
11
13
19
21
23
SUB FUNCTION
Program set
05
07
09
11
13
15
17
19
21
23
OPERATION
SET TEMP
Room Temp
Operation unit
On Off
Set no. Time 01
03
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
20 Multi Type Air Conditioner
17
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
AUTO SWING
• Fan speed is low.
15
HI
MED
LO
Time
Timer
• Fan speed is medium.
FAN SPEED
03
SUB FUNCTION
HI
MED
LO
Time
Operation unit
Timer
• Fan speed is high.
FAN SPEED
Program set
05
07
09
11
13
15
17
19
21
23
Operating Instructions
Comfort Operation with Swirl
• It is the function for comfort cooling/heating operation.
• The diagonal two louvers are opened the more larger than the other louvers.
After one minute, it is opposite.
9
ZO
11
13
Tim
Hea
CTIO
Defr ter P
N
Filte ost H rehea
r
um t
O idif
1
2 ut doo y
3
r
4
ET
NE
15
er
17
Ca
19
nc
Pr
og
ram
el
21
23
We
e
k
Ho
lid
Ho
ur
Min
ay
SE
T/C
LR
Pla
sm
a
RE
SE
T
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
Timer
Cancel
Program
Week
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
1
Press the On/Off Button.
The unit will respond with a
beep.
2
Press the Swirl Button to operate
comfort cooling or heating.
Then it will be changed the open
angle of two horizontal louvers.
3
To cancel the Swirl Mode, press the Swirl
Button again.
Program set
05
07
09
11
13
15
17
19
21
23
Holiday
Plasma
SET/CLR
Hour
Min
RESET
Owner’s Manual 21
Operating Instructions
Vane Control
You can change the open angle to the install situation.
1
Press the On/Off Button.
2
Press the right arrow and auto swing button simultaneously for three seconds.
Then the display will be toggled like before.
Detach your finger from buttons at the moment that it is displayed "P0" in the operation
display.
AUTO SWING
OPERATION
SET TEMP
FAN SPEED
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
Timer
On Off
Set no. Time 01
3
OPERATION
SET TEMP
Room Temp
03
Operation unit
03
AUTO SWING
OPERATION
05
07
09
11
SET TEMP
05
07
15
17
19
FAN SPEED
21
23
SUB FUNCTION
07
09
11
09
11
13
15
17
19
21
23
17
19
21
23
AUTO SWING
OPERATION
05
07
09
11
SET TEMP
03
15
17
19
FAN SPEED
21
23
SUB FUNCTION
07
09
11
15
17
19
21
23
AUTO SWING
OPERATION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
05
07
09
11
13
SET TEMP
15
03
19
21
23
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Operation unit
17
FAN SPEED
Room Temp
On Off
Set no. Time 01
SUB FUNCTION
HI
MED
LO
Program set
03
Program set
05
07
09
11
13
15
17
19
21
23
Press the right arrow button and Auto Swing button to finish the setting.
Min
+
Press the left arrow button and Auto Swing button for three seconds in order
to set the other two louvers. Next procedure is the same before.
Hour
6
FAN SPEED
Time
Operation unit
On Off
Set no. Time 01
Timer
13
SET TEMP
Room Temp
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
AUTO SWING
Timer
13
Room Temp
On Off
Set no. Time 01
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
03
Timer
15
FAN SPEED
HI
MED
LO
Time
Operation unit
On Off
Set no. Time 01
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
13
SET TEMP
Room Temp
Program set
05
OPERATION
HI
MED
LO
Time
Operation unit
03
AUTO SWING
Timer
13
Room Temp
Timer
SUB FUNCTION
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Program set
On Off
Set no. Time 01
On Off
Set no. Time 01
FAN SPEED
HI
MED
LO
Time
Timer
5
+
Min
Program set
Press the Auto Swing button again.
Then it will be changed the open angle of two horizontal louvers.
(from P0 to P5)
AUTO SWING
4
SUB FUNCTION
HI
MED
LO
+
Although the air conditioner is turned ON/OFF, the previous setting position is not changed
If you want to set the default position, you have to set the "P0". Because the default is the
"P0".
22 Multi Type Air Conditioner
Operating Instructions
Auto Swing Mode
Ca
og
ram
3
19
nc
Pr
el
4
21
23
We
e
k
Ho
lid
Ho
ur
Min
ay
SE
T/C
LR
Pla
sm
a
RE
SE
T
the On/Off
1 Press
button.
the Auto Swing
2 Press
button then the
(Confirm the unit
on operation.)
horizontal
louvers swing
up and down
automatically.
Press again the Auto
3 Swing
button to
cancel the
Auto Swing mode.
Child Lock Function
This is the Function that any children cannot used to the air-conditioner.
Operation procedure
1
To set the Child-Lock Function
Press the Timer button and Minute Set button for three seconds. Then the operation
mode shift to child lock mode and it is displayed ‘ CL ’ in the operation display.
When you press any button in this time, the remote controller is not converted to any
selected mode and the ‘ CL ’ is displayed in the remote controller for about three
seconds. But the Room Temperature function is operated in spite of child lock mode.
AUTO SWING
SET TEMP
Room Temp
Operation unit
03
Timer
Cancel
Program
Week
FAN SPEED
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
Program set
05
07
09
11
13
15
17
19
21
23
Holiday
Plasma
SET/CLR
Hour
2
OPERATION
Min
RESET
To cancel the Child-Lock Function
Press the Timer button and Minute Set button for three seconds. Then the
child-lock mode is cancelled and the preselected mode is displayed in the remote
controller.
Helpful information
Fan speed and cooling capacity.
The cooling capacity indicated in the specification is the value when the
fan speed is set to high, and the capacity will be lower at low or medium
fan speed.
High fan speed is recommended when you wish to cool the room quickly.
High
Speed
Owner’s Manual 23
Operating Instructions
Forced Operation
Operation procedures when the remote control can't be used.
Press the tact switch (Forced operation) for 2 seconds.
If you want to stop operation, press again the tact switch.
In case the power comes on again after power failure on the Forced
Operation mode, the operating conditions are automatically set as
follows:
During Forced Operation, the initial mode continues.
Heat pump Model
Cooling Model
Operating mode
Indoor FAN Speed
Setting Temperature
Forced operation
(Tact switch)
Room Temp. ≥ set Temp.-2°C Room Temp. < set Temp.-2°C
Cooling
Heating
set available
set available
set available
set available
Cooling
High
22°C
Auto Restart Function
In case the power comes on again after a power failure, Auto Restarting Operation is the function to operate
procedures automatically to the previous operating conditions.
Tips for Filter sign LED
1
Filter sign lamp (LED) is ON.
2
If LED indicating filter sign lamp is ON, clean the filter.
3
After cleaning the filter, press the Timer button and
Then filter sign LED is OFF.
button of wired remote controller at the same time for 3 sec.
PLASMA Purification Operation (Optional)
AUTO SWING
OPERATION
SET TEMP
Room Temp
Operation unit
03
Timer
Cancel
Program
Week
SUB FUNCTION
HI
MED
LO
AUTO Heater Preheat
JET Defrost Humidify
Filter Out door
ZONE
1 2 3 4
Time
Timer
On Off
Set no. Time 01
FAN SPEED
07
09
11
13
15
17
19
21
23
Holiday
Plasma
Min
Press the On/Off button. The unit will
respond with a beep.
2
Open the door on the remote control. Press the
PLASMA air purifying operation ON/OFF button.
Operation will start when the button is pressed and
stop when the button is pressed again.
Program set
05
SET/CLR
Hour
1
RESET
24 Multi Type Air Conditioner
3
Plasma
Set the fan speed again with door of the remote
control closed. You can select the fan speed in four
steps-low, medium, high or Auto.
Each time the button is pressed, the fan speed
mode is shifted.
✴ Air purifying operation (PLASMA) with cooling, heating
or any other operations.
Maintenance and Service
Maintenance and Service
CAUTION: Before performing any maintenance, turn off the main power to
the system.
Grille, Case, and Remote Control
❏ Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.
NOTICE
Supply power must be disconnected before
cleaning the indoor unit.
Anti-biofilter
Air
Intake
Air Outlet
Air Filters
Remote
Controller
The air filters behind the front grille should be checked and
cleaned once every 2 weeks or more often if neccessary.
1. Remove the Air filters.
■ Take hold of the tab and pull slightly forward
to remove the filter.
CAUTION: When the air filter is
to be removed, do not touch the
metal parts of the indoor unit.
It may cause an injury.
Rack
2. Clean dirt from the air filter using a vacuum
cleaner or washing with water.
■ If dirt is conspicuous, wash with a neutral
detergent in lukewarm water.
■ If hot water (50°C or more) is used, it may be
deformed.
Air Filter
■ Never use any of the followings:
• Water hotter than 40°C.
Could cause deformation and/or
discoloration.
• Volatile substances.
Could damage the
surfaces of the air
SI
N NER
conditioner.
Be
n zene
3. After washing with water, dry well in
the shade.
■ Do not expose the air filter to direct
sunlight or heat from a fire when drying
it.
4. Install the air filter.
SCO
U RIN G
C LB
A R GER
Owner’s Manual 25
Maintenance and Service
When the air conditioner is not going to be used for a long time.
When it is not going to be used for
a long time.
When the air conditioner is to be used again.
Operate the air conditioner at the
following settings for 2 to 3 hours.
• Type of operation: Fan operation
mode.(Refer to page 20)
• This will dry out the internal mechanisms.
Turn off the breaker.
Clean the air filter and install it in the
indoor unit.
(Refer to page 25 for cleaning it.)
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
CAUTION
Turn off the breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a fire.
Check that the ground wire is
connected correctly. It may be connect
to the indoor unit side.
Helpful information
The air filters and your electiric bill.
If the air filters become clogged with dust, the
cooling capacity will drop, and 6% of the electricity
used to operate the air conditioner will be wasted.
Operation Tips
Do not overcool the room.
Keep blinds or curtains
closed.
Keep the room temperature
uniform.
This is not good for the health
and wastes electricity.
Do not let direct sunshine
enter the room when the air
conditioner is in operation.
Adjust the vertical and
horizontal airflow direction to
ensure a uniform temperature
in the room.
Make sure that the doors
and windows are shut tight.
Clean the air filter regularly.
Ventilate the room
occasionally.
Avoid opening doors and
windows as much as possible
to keep the cool air in the
room.
Blockages in the air filter
reduce the airflow and lower
cooling and dehumidifying
effects. Clean at least once
every two weeks.
26 Multi Type Air Conditioner
Since windows are kept
closed, it is a good idea to
open them and ventilate the
room now and then.
Maintenance and Service
Before you call for service...
?
Troubleshooting Tips! Save time and money!
Check the following points before requesting repairs or service.... If the malfunction persist,
please contact your dealer.
The air conditioner
does not operate.
The room has a
peculiar odor.
It seems that
condensation is
leaking from the air
conditioner.
Air conditioner does
not operate for about
3 minutes when
restart.
• Check that this is not
a damp smell exuded
by the walls, carpet,
furniture or cloth
items in the room.
• Condensation occurs
when the airflow from
the air conditioner
cools the warm room
air.
• This is the protector
of the mechanism.
• Wait about three
minutes and
operation will begin.
Does not cool or heat
effectively.
The air conditioner
operation is noisy.
Crack sound is
heard.
• Is the air filter dirty?
See air filter cleaning
instructions.
• The room may have
been very hot when
the room air
conditioner was first
turned on. Allow time
for it to cool down.
• Has the temperature
been set incorrectly?
• Are the indoor unit's
air inlet or outlet vents
obstructed?
• For a noise that
sounds like water
flowing.
-This is the sound of
freon flowing inside
the air conditioner
unit.
• For a noise that
sounds like the
compressed air
releasing into
atmosphere.
-This is the sound of
the dehumidifying
water being
processed inside the
air conditioning unit.
• This sound is generated
by the expansion/
constriction of the front
panel, etc. due to
changes of
temperature.
• Have you made a
mistake in timer
operation?
• Has the fuse blown
or has the circuit
breaker been
tripped?
Remote control
display is faint, or no
display at all.
• Are the batteries
depleted?
• Are the batteries
inserted in the
opposite (+) and (-)
directions?
Filter sign lamp
(LED) is ON.
• Cleaning the filter,
press the Timer button
and button of wired
remote controller at
the same time for 3
sec.
NOTICE
WATER RESISTANT: The outdoor side of this appliance is WATER RESISTANT.
The indoor side is not water resistant and should not be exposed to
excess water.
Owner’s Manual 27
28 Multi Type Air Conditioner